MONTHYEARML20210Q4191999-08-10010 August 1999 Notice of Violation from Insp on 990619-0723.Violation Noted:Within 2 Hours of Removing Div 1 Diesel Generator 11 from Svc Licensee Failed to Verify That Components Depending on Div 2 Diesel Were Operable ML20210J2201999-07-23023 July 1999 Notice of Violation from Insp on 990524.Violation Noted: on 980920 Kf Enoch Engaged in Deliberate Misconduct That Caused Licensee to Be in Violation of Condition of License ML20207J1531999-03-0808 March 1999 Notice of Violation from Insp on 990111-29.Violation Noted: as of Jan 1999,calculation DC-0367, Design Calculations for RHR Sys, Rev 6,incorrectly Concluded That Stated Item Would Occur ML20154D1361998-09-30030 September 1998 Notice of Violation from Insp on 980304-0702.Violation Noted:On 980213,individual Failed to Contact Radiation Protection Dept for Appropriate Radiological Briefing ML20236R1251998-07-15015 July 1998 Notice of Violation from Insp Completed on 970922.Violation Noted:Licensee Made Revs to Procedures as Described in Safety Analysis Rept W/O Receiving Prior Commission Approval ML20236Q9241998-07-14014 July 1998 Notice of Violation from Insp on 980504-0618.Violation Noted:Operators Were Making Changes to Facility by Defeating Various Control Room Annunciators W/O Performing Written Safety Analysis Rept ML20247D4371998-05-0606 May 1998 Notice of Violation from Insp on 980406-09.Violation Noted: on 980120,two Mechanical Maint Staff Entered North Reactor Water Cleanup Room,Locked High Radiation Area,W/O Stay Time Tracking & Deviation Not Authorized by Radiation Protection ML20217K2531998-03-31031 March 1998 Notice of Violation from Insp on 971113-980226.Violation Noted:Inspector Identified That on 971115,licensee Removed Multiple Fuel Rods from Irradiated Fuel Bundle YJ7119,up to Four at One Time,During Failed Fuel Insp Activities ML20216B5451998-03-0404 March 1998 Notice of Violation from Insp on 970804-1010.Violation Noted:Analysis Did Not Consider All Scenarios in Providing Bases for Determination That USQ Did Not Exist ML20202H8531998-01-0303 January 1998 Notice of Violation from Insp on 970923-1107.Violation Noted:On 971027 W/Edg 14 Inoperable,Licensee Identified That Operators Failed to Perform Verification Checks in SR 4.8.1.1.1 at Least Once Per Eight Hours ML20216J4531998-01-0202 January 1998 Notice of Violation from Insp on 970923-1107.Violation Noted:On 971027,w/EDG 14 Inoperable,Licensee Identified That Operators Failed to Perform Verification Checks in SR 4.8.1.1.1,at Least Once Per 8 Hours ML20217A9611997-12-0808 December 1997 Notice of Violation from Insp Completed on 970421.Violation Noted:On 960903,M Redlin & Employee of Numanco,Contractor at Plant,Unit 2 Answered No to Question on Ltr of Certification About Past Drug Use ML20198N3261997-10-29029 October 1997 Notice of Violation from Insp on 970804-1010.Violations Noted:Info in TSs & UFSAR Was Not Complete & Accurate in All Matl Respects ML20212F4311997-10-27027 October 1997 Notice of Violation from Insp on 970811-0922.Violation Noted:Inspectors Identified That on 960727,licensee Failed to Initiate DER Following Calibration of Div 2 Oxygen Monitor,During Which 2 Nonconservative Shifts Identified ML20211C3581997-09-23023 September 1997 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000.Violation Noted:Motor Control Ctr Fuse Disconnect Switch Installed in Safety Sys Failed to Remain Closed,Significant Condition Adverse to Quality ML20210R6581997-08-26026 August 1997 Notice of Violation from Insp on 970508-0630.Violation Noted:On 970624,licensee Identified That B RHRSW Cooling Tower Fan Rendered Inoperable for Planned Maintenance W/O Demonstrating Operability of Remaining AC Sources ML20149K8651997-07-0101 July 1997 Notice of Violation from Insp on 970320-0509.Violation Noted:On 970410,inspectors Identified That Work Request OOOZ974252 Specified Selected Steps from Procedure 44.060.001 as Post Maint Testing for Corrective Maint ML20148N1391997-06-19019 June 1997 Notice of Violation from Insp on 970512-30.Violation Noted:Licensee Failed to Perform PMT to Ensure That New Deficiency Was Not Created Due to Maint ML20140D3321997-06-0202 June 1997 Notice of Violation from Insp on 970201-0319.Violation Noted:Inspectors Identified That Licensee Did Not Have Prepared Instructions for Energizing & Startup of Bus 302 in Offsite Electrical Sys ML20148B8931997-05-0707 May 1997 Correction to NOV from Insp on 930916-24 & 1018-1104. Violation Noted:Personnel Signing Off as Lead Test Person for Tests Conducted 1991 on Div 1 & 2 Standby Gas Treatment Filters Were Not Certified to ANSI N45.2.6 ML20135B6771997-02-24024 February 1997 Notice of Violation from Insp on 961202-970207.Violation Noted:Review of Eight Contractor Security Officer Background Investigation Files Showed That Employment Verification Status of Five Applicants ML20134P5051997-02-0606 February 1997 Notice of Violation from Insp on 961026-1216.Violation Noted:Licensee Failed to Take Actions to Correct Deficiency of Loose Muffler ML20134B8551997-01-23023 January 1997 Notice of Violation from Insp on 960914-1025.Violation Noted:Test Personnel Failed to Stop Test & Promptly Restore Shutdown Cooling IAW Sequence of Events Test 96-07 Re Infrequently Preformed Test or Evolution 96-05 ML20129E9261996-09-26026 September 1996 Notice of Violation from Insp on 960629-0802.Violation Noted:Adequate Corrective Actions to Preclude Repetition of Significant Condition Adverse to Quality Previously Identified on 960331,were Not Taken ML20059B2761993-12-28028 December 1993 Notice of Violation from Insp on 931115-23.Violation Noted: on Four Occasions Personnel Have Been W/Unescorted Access Authorization to Protected Area ML20058E1871993-11-23023 November 1993 Notice of Violation from Insp on 930916-24 & 931018-1104. Violation Noted:Failed to Provide Training to Three Lead Test Personnel ML20059M5581993-11-10010 November 1993 Notice of Violation from Insp on 930909-1105.Violation Noted:Operators Failed to Implement ARP 4D40 When Low Gland Steam Pressure Annunciator Alarm Was Received Subsequent to Reactor Trip ML20056E1551993-08-13013 August 1993 Notice of Violation from Insp on 930524-0608.Violation Noted:Two Channels of Wide Range Drywell Pressure Post Accident Monitoring Instrumentation Sys Inoperable from 921104 Until 930107 ML20126B7271992-12-16016 December 1992 Notice of Violation from Insp Under NPF-43.Violation Noted:Employee of Facility Engaged in Action Compromising Integrity of Application or Exam Required by 10CFR55 ML20126B3951992-12-11011 December 1992 Notice of Violation from Insp on 921014-1208.Violation Noted:Failure to Comply W/Ts Overtime Requirements Previously Identified by Licensee in Apr-May 1991 Not Corrected & Failures Occurred Again in Sept 1992 ML20127D7241992-09-0909 September 1992 Notice of Violation from Insp on 920701-0824.Violation Noted:Access to Welding Matls Storage Area Not Properly Controlled in That Door Locking Mechanism Removed & Storage Area Left Unattended ML20217D0741991-07-11011 July 1991 Notice of Violation from Insp on 910429-0510,23,31 & 0603. Violation Noted:Surveillance Procedures for RPS Electrical Protection Assembly Calibr/Functional Tests Did Not Include Appropriate Quantitative or Qualitative Acceptance Criteria ML20055D8481990-06-27027 June 1990 Notice of Violation from Insp on 900331-0525.Violations Noted:Failure to Prescribe Adequate Instructions for Bypass Valve Rebuilding Effort & to Establish Adequate Measures for Reviewing Documents Associated W/Rebuilding Bypass Valves ML20246K4571989-07-11011 July 1989 Notice of Violation from Insp on 890411-0605.Violations Noted:Testing of 16 air-operated Containment Isolation Valves Was Not Adequate to Properly Demonstrate Operability ML20247Q1211989-06-0101 June 1989 Notice of Violation from Insp on 890218-0410 & 0517-19. Violation Noted:Operators Did Not Maintain Drywell to Torus Differential Pressure at Any Time While Plant Operating Since Jul 1985 ML20247N2961989-05-31031 May 1989 Notice of Violation from Insp on 890515-19.Violation Noted:Licensee Supervisor Failed to Either Sign & Process Several DERs Prepared by Subordinates or Provide Written Explanations Re Conditions Adverse to Quality ML20247J2591989-05-23023 May 1989 Notice of Violation from Insp on 890105-06,13-14 & 25. Violations Noted:Licensee Notified of Conditions Adverse to Quality & Failed to Correct Conditions in Timely Manner ML20245H7451989-04-21021 April 1989 Notice of Violation from Insp on 890118-0323.Violation Noted:Nuclear Engineering Did Not Initiate Deviation Rept as Required When Design Calculation 4572 & Procedure 44.020.204 Found W/Incorrect Head Correction Factor ML20244A7181989-04-0404 April 1989 Notice of Violation from Insp on 881212-890323.Violation Noted:During Later Half of 1988,licensee Administratively Closed 86 Deviation Event Repts & Nonconformance Repts W/O All Corrective Actions Completed ML20235Z6291989-03-0606 March 1989 Notice of Violation from Insp on 890101-0217.Violation Noted:Numerous Gaskets,Filters,Bolts,Nuts & Relief Valves for Emergency Diesel Generators Stored in Trailer W/O Access Controls ML20206L5591988-11-23023 November 1988 Notice of Violation from Insp on 880308-0920.Violation Noted:Engineering Evaluations Used to Select Diodes,Valves & Gears That Were Not safety-related for Applications Did Not Ensure Critical Characteristics Satisfied Requirements ML20206C6711988-11-0404 November 1988 Notice of Violation from Insp on 871018-880826.Violations Noted:Div 1 Portion of Procedure 24.413.01 Not Accomplished within 92 Day Time Interval & Failure to Perform Channel Check on Reactor Protection Sys ML20154P8831988-09-27027 September 1988 Notice of Violation from Insp on 880815-0909.Violation Noted:Procedures Established to Control Vendor Equipment Technical Info Not Adequate to Ensure That Only Reviewed, Approved & Current Vendor Technical Info Used at Work ML20207B7381988-07-25025 July 1988 Notice of Violation from Insp on 880401-0527.Violation Noted:Drywell High Pressure Channel C Instrument Inoperable in That Instrument Rack Valve Partially Closed,Generating Actuation Setpoint of Approx 2.38 Psig ML20196D3501988-06-28028 June 1988 Notice of Violation from Insp on 880516-20 & 0606-10. Violation Noted:Prior to 880610,controlled Copies of Maint Instructions Prescribing Activities Affecting Quality Exceeded 2-yr Review Cycle ML20155J9971988-06-16016 June 1988 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $200,000.Violations Noted:On 871017,containment Isolation Configuration for Primary Containment Radiation Monitoring Sys Violated Requirements of GDC 56 ML20197F2401988-05-27027 May 1988 Notice of Violation from Insp on 880206-0331.Violation Noted:Failed to Show Organization for Unit Mgt & Technical Support on Figure 6.2.1-1 & Unit Organization on Figure 6.2.2-1 ML20154E2611988-05-12012 May 1988 Notice of Violation from Insp on 870413-1019.Violation Noted:Written Safety Evaluation Not Conducted for Condition Outside Analyzed Licensing Basis of Facility & License Amend Not Sought for Unreviewed Safety Question/Tech Spec Change ML20151X8251988-04-22022 April 1988 Notice of Violation from Insp on 880307-25.Violations Noted: No Acceptance Criteria or Machining Dimensions & Tolerances Provided in MSIV Procedure or Work Request & Component Replacements Made on Control Panel Not Classified ML20149M7841988-02-23023 February 1988 Notice of Violation from Insp on 880202-05.Violation Noted:Fillet Weld Size for Column to Base Plate Attachment (12 Column Connections) Incorrectly Specified as 3/16 Inch. No Calculations Found to Ensure Adequacy of Design 1999-08-10
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000341/19990171999-10-21021 October 1999 Insp Rept 50-341/99-17 on 990927-1005.No Violations Noted. Major Areas Inspected:Incident Involving Loaded Firearm in Protected Area Identified on 990922 & Being Considered as Noncited Violation IR 05000341/19990111999-10-0707 October 1999 Insp Rept 50-341/99-11 on 990724-0908.Two NCVs Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000341/19990101999-08-10010 August 1999 Insp Rept 50-341/99-10 on 990619-0723.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support ML20210Q4191999-08-10010 August 1999 Notice of Violation from Insp on 990619-0723.Violation Noted:Within 2 Hours of Removing Div 1 Diesel Generator 11 from Svc Licensee Failed to Verify That Components Depending on Div 2 Diesel Were Operable IR 05000341/19990061999-08-0606 August 1999 Insp Rept 50-341/99-06 on 990712-0716.No Violations Noted. Major Areas Inspected:Review of Various Aspects of Licensee Chemistry & Radiation Protection Programs,Specifically in Listed Areas ML20210J2201999-07-23023 July 1999 Notice of Violation from Insp on 990524.Violation Noted: on 980920 Kf Enoch Engaged in Deliberate Misconduct That Caused Licensee to Be in Violation of Condition of License IR 05000341/19990091999-07-12012 July 1999 Insp Rept 50-341/99-09 on 990516-0618.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maint & Plant Operations IR 05000016/19990011999-06-30030 June 1999 Insp Rept 50-016/99-01 on 990614-17.No Violations Noted. Major Areas Inspected:Mgt & Control,Decommissioning Support Activities,Industry Safety & Radiological Safety IR 05000341/19990071999-06-0101 June 1999 Insp Rept 50-341/99-07 on 990402-0515.Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering, Maint & Plant Support IR 05000341/19990041999-05-26026 May 1999 Insp Rept 50-341/99-04 on 990503-07.No Violations Noted. Major Areas Inspected:Radiological Emergency Response Preparedness Program,Aspect of Plant Support IR 05000341/19990081999-04-29029 April 1999 Partially Withheld (Ref 10CFR73.21) Insp Rept 50-341/99-08 on 990405-09.No Violations Noted.Major Areas Inspected: Physical Protection Program,Aspect of Plant Support IR 05000341/19990031999-04-23023 April 1999 Insp Rept 50-341/99-03 on 990218-0401.Two Violations Noted & Being Treated as non-cited Violations.Major Areas Inspected: Operations,Engineering,Maint & Plant Support ML20205P1751999-04-14014 April 1999 Insp Rept 50-341/99-06 on 990315-19.No Violations Noted. Major Areas Inspected:Licensee Plant Support Performance Re Gaseous & Liquid Effluents,Liquid Waste Processing,Esf Filtration & CR Heating Ventilation & Air Conditioning IR 05000341/19990051999-03-19019 March 1999 Insp Rept 50-341/99-05 on 990308-11.No Violations Noted. Major Areas Inspected:Reviewed Fire Protection Program,An Aspect of Plant Support IR 05000341/19990021999-03-0808 March 1999 Insp Rept 50-341/99-02 on 990111-29.Violations Noted.Major Areas Inspected:Review of Engineering & Technical Support & Corrective Actions ML20207J1531999-03-0808 March 1999 Notice of Violation from Insp on 990111-29.Violation Noted: as of Jan 1999,calculation DC-0367, Design Calculations for RHR Sys, Rev 6,incorrectly Concluded That Stated Item Would Occur IR 05000341/19980151999-02-22022 February 1999 Errata to Insp Rept 50-341/98-15.Rept Incorrectly Documented That Loose Internal Sleeving on Turbine Control Valve Caused Power Oscillations Greater than 10% During Plant Operation IR 05000341/19980191999-01-21021 January 1999 Insp Rept 50-341/98-19 on 981110-990104.No Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support ML20198D5671998-12-0707 December 1998 Insp Rept 50-341/98-15 on 980922-1109.Noncited Violations Were Identified.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000341/19980171998-11-16016 November 1998 Insp Rept 50-341/98-17 on 980909-1021.No Violations Noted. Major Areas Inspected:Review of Implementation of Inservice Insp Program for Plant Refueling Outage 6 PNO-III-98-055, on 981113,licensee Shut Unit Down to Repair Steam Leak from Reactor Feedwater Check Valve.Valve Is SR & Would Provide Containment Isolation Function Under Accident Conditions1998-11-13013 November 1998 PNO-III-98-055:on 981113,licensee Shut Unit Down to Repair Steam Leak from Reactor Feedwater Check Valve.Valve Is SR & Would Provide Containment Isolation Function Under Accident Conditions IR 05000341/19980181998-10-30030 October 1998 Insp Rept 50-341/98-18 on 981006-08.No Violations Noted. Major Areas Inspected:Licensee Implementation of 10CFR50.65, Requirements for Monitoring Effectiveness of Maintenance at Nuclear Power Plants PNO-III-98-048, on 981008,Detroit Edison Declared Alert Based on Operator Rept of Smoke & Fire Alarm Coming from EDG 12 Control Panel in Switchgear Room.Operator Tripped EDG 12, Opened Output Breaker & Left Switchgear Room1998-10-21021 October 1998 PNO-III-98-048:on 981008,Detroit Edison Declared Alert Based on Operator Rept of Smoke & Fire Alarm Coming from EDG 12 Control Panel in Switchgear Room.Operator Tripped EDG 12, Opened Output Breaker & Left Switchgear Room IR 05000341/19980131998-10-20020 October 1998 Insp Rept 50-341/98-13 on 980730-0921.No Violations Noted. Major Areas Inspected:Aspects Oflicensee Operations, Engineering,Maint & Plant Support IR 05000341/19980161998-10-0606 October 1998 Insp Rept 50-341/98-16 on 981014-18.No Violations Noted. Major Areas Inspected:Alara Planning & Controls for Sixth Refueling Outage,Internal Exposure Monitoring,Radiological Surveys & Posting & Radiation Worker Performance IR 05000016/19980071998-09-30030 September 1998 Insp Rept 50-016/98-07 on 980909-11.No Violations Noted. Major Areas Inspected:Licensee Mgt & Control,Decommissioning Support Activities,Industrial Safety & Radiological Safety ML20154D1361998-09-30030 September 1998 Notice of Violation from Insp on 980304-0702.Violation Noted:On 980213,individual Failed to Contact Radiation Protection Dept for Appropriate Radiological Briefing IR 05000341/19980121998-09-0101 September 1998 Insp Rept 50-341/98-12 on 980619-0803.Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support ML20236R1251998-07-15015 July 1998 Notice of Violation from Insp Completed on 970922.Violation Noted:Licensee Made Revs to Procedures as Described in Safety Analysis Rept W/O Receiving Prior Commission Approval ML20236Q9241998-07-14014 July 1998 Notice of Violation from Insp on 980504-0618.Violation Noted:Operators Were Making Changes to Facility by Defeating Various Control Room Annunciators W/O Performing Written Safety Analysis Rept IR 05000341/19980081998-07-14014 July 1998 Insp Rept 50-341/98-08 on 980504-0618.Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Engineering, Maint & Plant Support IR 05000341/19980101998-06-29029 June 1998 Insp Rept 50-341/98-10 on 980608-12.No Violations Noted. Major Areas Inspected:Plant Support & Evaluation of Licensee Performance During Station Biennial Exercise of Emergency Plan IR 05000341/19983011998-06-29029 June 1998 NRC Operator Licensing Exam Rept 50-341/98-301OL(including Completed & Graded Tests) for Tests Administered on 980406- 0520.Six Applicants Were Administered Exam,Two Failed Written Exam,Two Failed Operating Exam & One Failed Both IR 05000341/19980111998-06-25025 June 1998 Insp Rept 50-341/98-11 on 980608-12.No Violations Noted. Major Areas Inspected:Radiological Controls for Spent Fuel Pool Clean Out Project IR 05000341/19980091998-06-0404 June 1998 Insp Rept 50-341/98-09 on 980511-15.No Violations Noted. Major Areas Inspected:Aspects of Licensee Performance Re Physical Security for Facility IR 05000341/19980061998-06-0303 June 1998 Insp Rept 50-341/98-06 on 980317-0427.No Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant Support IR 05000341/19980031998-05-11011 May 1998 Insp Rept 50-341/98-03 on 971221-980316.Violations Noted. Major Areas Inspected:Aspects of Licensee Operations, Engineering,Maint & Plant Support ML20247D4511998-05-0606 May 1998 Insp Rept 50-341/98-07 on 980406-09.Violations Noted.Major Areas Inspected:Plant Support ML20247D4371998-05-0606 May 1998 Notice of Violation from Insp on 980406-09.Violation Noted: on 980120,two Mechanical Maint Staff Entered North Reactor Water Cleanup Room,Locked High Radiation Area,W/O Stay Time Tracking & Deviation Not Authorized by Radiation Protection IR 05000016/19980061998-04-21021 April 1998 Insp Rept 50-016/98-06 on 980324-26.No Violations Noted. Major Areas Inspected:Licensee Mgt & Control,Decommissioning Support Activities & Radiological Safety ML20216E7901998-04-10010 April 1998 Insp Rept 50-341/98-05 on 980320-0406.Violations Noted: Failure to Demonstrate Reactor Protection Sys Trip Function Units & Isolation Actuation Trip Units within Response Time Limit of at Least Once Per 18 Months IR 05000341/19980041998-03-31031 March 1998 Insp Rept 50-341/98-04 on 971113-980226.Violations Noted. Major Areas Inspected:Operations,Engineering & Plant Support ML20217K2531998-03-31031 March 1998 Notice of Violation from Insp on 971113-980226.Violation Noted:Inspector Identified That on 971115,licensee Removed Multiple Fuel Rods from Irradiated Fuel Bundle YJ7119,up to Four at One Time,During Failed Fuel Insp Activities ML20217K2681998-03-31031 March 1998 Notice of Deviation from Insp on 971113-980226.Deviation Noted:Licensee Stored Irradiated Fuel in West Fuel Preparation Machine in Sf Pool Oversight on 971114-15 & 971115-17,resulting in Only 20.5 Feet Water Above Top of Sf ML20217K2821998-03-31031 March 1998 Insp Rept 50-341/98-04 on 971113-980226.Violations Noted. Major Areas Inspected:Operations,Engineering & Plant Support ML20216B5451998-03-0404 March 1998 Notice of Violation from Insp on 970804-1010.Violation Noted:Analysis Did Not Consider All Scenarios in Providing Bases for Determination That USQ Did Not Exist IR 05000341/19970161998-02-0505 February 1998 Insp Rept 50-341/97-16 on 981108-0105.Noncited Violation Identified.Major Areas Inspected:License Operations,Maint, Engineering & Plant Support PNO-III-98-015, on 980201,reactor Scrammed from 96% Power Following Trip of Main Turbine.Main Turbine Trip Resulted from Main Generator Load Rejection Protective Signal. Investigation Continuing1998-02-0404 February 1998 PNO-III-98-015:on 980201,reactor Scrammed from 96% Power Following Trip of Main Turbine.Main Turbine Trip Resulted from Main Generator Load Rejection Protective Signal. Investigation Continuing IR 05000341/19970171998-01-21021 January 1998 Insp Rept 50-341/97-17 on 971201-05.No Violations Noted. Major Areas Inspected:Conduct of Operations,Operator Training & Qualification & Miscellaneous Operations Issues ML20202H8581998-01-0303 January 1998 Insp Rept 50-341/97-14 on 970923-1107.Violations Noted. Major Areas Inspected:Operations,Engineering,Maintenance & Plant Support 1999-08-06
[Table view] |
Text
.
NOTICE OF VIOLATION Detroit Edison Company Docket No. 50-341 Fermi 2 Power Plant License No. NPF-43 During an NRC inspection conducted between September 16 through 24, and October 18 through November 4,1993, two violations of NRC requirements were identified. In accordance with the "GeneralStatement of Policy and Procedure for NRC Enforcement Actions," 10 CFR Part 2, Appendix C, the violations are listed below:
A. 10 CFR Part 50, Appendix B, Criterion XVI, states, in part, " Measures shall be established to assure that conditions adverse to quality, such as failures, malfunctions, deficiencies, deviations, defective material and equipment, and nonconformances are promptly identified and corrected."
Contrary to the above, as of the inspection conducted September 24,1993, training required by FIP-TQl-16-SO, Revision 2, to certify lead test personnel to 2 ANSI /ASME N510 requirements for HEPA filter testing had not been provided to l three (3) lead test personnel. The failure to provide training constituted a condition adverse to quality identified in 1991 which was not promptly corrected.
This is a Severity Level IV violation. ,
B. 10 CFR Part 50, Appendix B, Criterion V, states,in part, " Activities affecting ;
quality shall be prescribed by documented instructions, procedures, or drawings, of a type appropriate to circumstances and shall be accomplished in accordance with these instructions, procedures, or drawings." >
Contrary to the above, personnel signing off as the lead test person for the tests conducted in 1991 on Division 1 and Division 2 Standby Gas Treatment Filters, and Control Room Emergency Filter were not certified to ANSI N45.2.6 as required by test procedures 43.505.001, 43.404.002, and 43.413.001.
This is a Severity Level IV violation.
The inspection showed that steps had been taken to correct the identified violations and to prevent recurrence. Consequently, no reply to the vio'stions is required and we have no further questions regarding this matter.
1 I
1 l
i i
9705130402 970507 PDR ADOCK 05000341 )
O PDR i
..= - -- - - . - - . - _- - .. - - . -. -- - - -
4 EXECUTIVE
SUMMARY
Enrico Fermi, Unit 2 NRC Inspection Report 50-341/93020 l This inspection included a review of the quality assurance (QA) program, it was an i
announced inspection conducted by a regional reactor inspector.
- The objective of this inspection was to examine portions of the licensee's CA program.
l The inspector interviewed staff, reviewed documents and made observations to accomplish this objective. This inspection focused on QA activities performed during 1989 through 1991. Two violations of NRC requirements were identified in this inspection for events that occurred in that period. One violation was for not meeting the procedural requirements and the other was for inadequate corrective actions.
The following changes were made to the report:
The following statements from the original report were determined to be inaccurate and were removed:
In the Notice of Violation, the reference to the Enforcement Policy was corrected.
in (original) Section 3.1 " Evaluation of ANSI /ASME N510 Qualification and Certification for Testing Personnel":
- 1. The last sentence of the first paragraph reading " Based on observations of documentation, NRC determined that HEPA filter surveillance tests, conducted in conducted in 1989 and 1991, were performed under the supervision of certified inspectors." Further evaluation identified that ~ths 1
@y[y Bgy@j@@R{j@lR$@@JiMfgri@@j while certified !
inspectors were onsite, and had conducted on-the-job training on filter testing, the surveillance tests were not entirely performed under the j supervision of certified inspectors, j
- 2. The first sentence in the fourth paragraph reading "The NRC inspector evaluated test documentation and determined that the tests were technically adequate based on the presence of a certified contractor and another corporate office certified inspector" and the third sentence in the same paragraph reading " Quality Assurance management used the security log as evidence that the certified inspectors were present and monitored the three conducted tests." Following identification that the certified individuals were not in the test vicinity throughout the test, the NRC inspectors reevaluated the test results and determined that they were technically adequate based upon comparable results achieved during more recent testing. Review of written statements determined that the Quality Assurance management had not stated that the security logs confirmed certified individuals were present and monitored the tests, but rather stated that certified individuals were onsite throughout the testing period and provided oversight of the tests.
- 3. The beginning of the sixth sentence in the fourth paragraph reading "The I licensee has implemented training for ANSl/ASME N510" and the third 2
'O f S
~+.-_w *~ ..w- n - 2-w..-~x + . a .- --.u-~ .
Based on these changes, the inspectors concluded that:
4 The corrections being made herein to inspection Report (IR) 93020 did not affect
- the previous technical conclusions or any previous decisions regarding equipment operability or adherence to regulatory requirements.
Problems with the DER process continued to occur, following issuance of IR 93020.
i These problems included identification of issues, thoroughness of root cause !
determinations, and adequacy of corrective actions to prevent recurrence. During i the Systematic Assessment of Licensee Performance (SALP) public meeting in l March 1996, the issue of problem identification and resolution was discussed by both the NRC and the licensee.
- 1. Maintenance M2 Maintenance Support of Facilities and Equipment
- M 2.1 Maintenance and Test Ecuioment (M&TE) Control (Formerly Section 3.6) 4 in M93, the NRC inspector evaluated only the retrieval and storage of M&TE 1
records from the vault. This evaluation also included review of selected records
- and interview with responsible individuals. The inspector concluded that there were l no significant concerns or findings in this area and noted the overall control of M&TE records had been previously inspected by the NRC. NRC concerns regarding
- retrieval and storage of M&TE records had been addressed by the licensee. In
, 1995, because of continuing concerns with the M&TE program, the NRC performed 4
a more through review of the entire M&TE program, as documented in IR 95008.
Retrieval and storage of M&TE records were verified as part of this wider inspection and no problems were found during that portion of the inspection. The 1995 inspection identified several problems with the M&TE program, as well as a violation associated with a Quality Assurance (QA) audit of the program in 1993. 1
,i The inspection report also noted that some problems identified by QA in 1991 had I been corrected, such as control of leak rate test and motor-operated valve testing equipment.
]
M4 Maintenance Staff Knowledge and Performance M4.1 Certification and Qualification of QA Insoectors and Auditors (Formerly part of l Section 3.1) l
{ a. Scope j The NRC inspector examined the certification and qualification requirements /
! records for QA inspectors and auditors. This examination generally covered the i overall certification process.
L
- b. _Qbservations and Findinas in 1993, the inspector determined that selective examinations of certification 4
records for inspectors and auditors did not identify regulatory deficiencies. The 4 l 4
l l
l issue of QA ins 9ector certification was again reviewed in IR 95012. As described in that report, aeveral deficiencies with the QA inspector certification process were identified in QA audits in 1989 and 1991. Further review of the audit reports and discussion with audit personnel revealed that minimal corrective actions were taken following the 1989 audit findings. However, when the same problems were discovered during the 1991 audit, the QA auditors correctly escalated the issue and the certification process was corrected, including bringing in an outside consultant !
to recertify the inspectors in question. The inspectors also identified a concern i with the certification and technical ability of one inspector. This was addressed in IR 96002. The qualifications and training of lead auditors were reviewed by NRC in irs 93002,94015, and 95002. In all cases, the auditors were found to have the appropriate training and background prior to being assigned as lead auditors for the audits reviewed.
- c. Conclusions Based upon the inspections listed above, the inspectors concluded that the QA inspectors and auditors were properly trained and certified. While problems with QA inspector certifications existed in 1989 and 1991, the licensee's OA auditors correctly escalated the finding and the licensee took appropriate corrective action solve it.
M4.2 Evaluation of ANSI /ASME N510 Qualification and Certification of Testina Personnel (Formerly Section 3.1)
- a. Scooe '
The inspectors rev! awed the qualifications and training on ANSI /ASME N510
" Testing of Nuclear Air-Cleaning Systerns," for personnel testing high energy particulate (HEPA) filters,
- b. Observations and Findings Three test procedures, 43.404.001, " Division 1 Standby Gas Treatment Filter Performance Test," 43.404.002, " Division 2 Standby Gas Treatment Filter Test,"
and 43.413.001, " Control Room Emergency Filter Test," required certification to ANSI N45.2.6, " Qualification of Inspection, Examination and Testing Personnel for Nuclear Power Plants," for the lead person conducting the tests. Each test procedure had a signature line for verification that the lead test person was certified to the above standard.
V' hen the three filter tests above were conducted in j 991, the lead test person signature line was signed by two individuals who were not ANSI N45.2.6 certified.
This was identified during a QA Audit, 91-0143. The licensee stated that the tests were performed under the auspices of a certified contractor, as well as a certified inspector from the corporate office. However, the QA audit noted that the signature lines for the above three tests were neither initialed nor signed by either of the certified individuals. Because the test procedures specifically required ANSI N45.2.6 certification and the lead persons were not certified, the licensee's procedural requirements were not met. 10 CFR Part 50, Appendix B, Criterion V 5
" Instructions, Procedures, and Drawings" requires that activities affecting quality be accomplished in accordance with the documented instructions, procedures, or I drawings. Failure to comply with the HEPA filter testing procedural requirements, I ensuring that the lead test person was certified to ANSI N45.2.6, is a violation of !
Criterion V (50-341/93020-01(DRS)). i Quality Assurance management reviewed the security logs and determined that the certified inspectors were on site, @gG@!dMg'eMij in the test area, during
{K@]l{p{yX@Bj@j when testing was being performed. The licensee also l obtained a letter from the contractor describing the ANSI /ASME N510 on-the-job l training conducted for the individuals. Subsequent HEPA filter [ tests were satisfactorily conducted by the same two individuals, indicating an adequate i knowledq9 level for performing HEPA filter testing. The licensee removed qualification to ANSI N45.2.6 as a requirement for HEPA filter testing, following confirmation from the ASME code committee that qualification to ANSI N45.2.6 was not required. Therefore the corrective action to the violation was considered adequate and no response is required.
Although certification to ANSI N45.2.6 was not required, qualification to ANSI /ASME N510-1980 was necessary. Section 4.3 of ANSI /ASME N510-1980, Page C-4, stated, " Tests shall be made only by persons who have demonstrated their competence to satisfactorily make the specific tests in question, as evidenced by experience and training." The two individuals who signed off as lead test personnel for the 1989 HEPA filter tests had not received training on ANSI /ASME N510. This was also identified by the licensee's QA auditors in audit 91-0143.
DER 91-0589 was generated which identified the lack of training and certification of the lead test personnel.
As part of the corrective action to DER 91-0589, the licensee developed a training course for ANSI /ASME N510. However, the licensee exempted three lead test personnel, including the two who had signed off on the [9M tests, principally because they participated in subsequent HEPA filter testing. The inspectors also noted that, as of December 1996, the licensee had not taught the course.
Furthermore, the waivers made no reference to training conducted for these individuals. According to FermiInterfacing Procedure FIP-TOI-16-SO Revision 2, requests for waivers "shall be supported by certified or authenticated documents such as official transcripts, verifiable certificates of completion, etc." No such documentation was identified to justify waiving the training requirement.10 CFR Part 50 Appendix B, Criterion XVI " Corrective Action" requires that significant conditions adverse to quality are promptly and adequately corrected. Therefore, waiving the training requirement in response to the DER appeared to constitute an inadequate corrective action. This is considered a violation (50-341/93020-02(DRS)).
The licensee presented the inspectors with plant records, including a statement from the certified contractor indicating the on-the-job training performed prior to and during the {99{ testing. Based on these records, the inspectors determined that, although the three lead test personnel did not receive formal training on ANSI /ASME N510, the on-the-job training appeared to be adequate. T he licen.see reviewed the procedure addressing waivers and determined it to be adequate co 6
- - . . - - - - ~ ~ - - - - - . - - - . . . - - . . - - - - - . -
- i. *
- preclude future waivers without sufficient basis. E
- ecause the subsequent actions
- appeared adequate, no response to the violation was required. Subsequently, it j was brought to the licensee's attention that no training was ever performed on ANSI /ASME N510, and that, despite the review and approval by the lead QA
} auditor, the closure package for 91-0589 was inadequate. A new DER, 94-0281, j was opened to correct the deficiencies of the original packags.
i ' The NRC inspectors reviewed the issue of the test signatures to determine if there l was any intent to falsify the records. To this end, the inspectors interviewed the ;
i personnel involved & the responsible QA auditors, reviewed the security logs, and
- evaluated the test documentation, including HEPA filter test results from ,
i subsequent years. Based on this review, the inspectors determined that the l l individuals and their management were aware that the individuals did not have l 4 ANSI N45.2.6 certification at the time they signed the HEPA filter test documents. l l However, to the best of the inspector's ability to determine, there was no intent to l
{- deceive anyone regarding performance of the test. The individuals' readily i j acknowledged they were not certified, the licensee's OA organization identified the )
- discrepancy; and the line management reviewed the issue and took actions to i prevent it from recurring. Therefore, the inspectors determined that the issue j centered upon the licensee not reviewing the appropriate procedures prior to use to
- ensure that all requirements were adequately met. ;
4
- c. Conclusions i NRC determined that the HEPA filter surveillance tests, conducted in]1991, were <
- performed adequately, ethough the licensee's proceduraliequirements were not i j followed. The violations issued in 1993 appropriately characterized the issues and J j no further corrective actions are necessary on the licensee's part.
l M4.3 Adeausev of Insoectors Knowledae Concernina Selection Criteria About Installation l of Snubbers (Formerly Section 3.4)
! During the inspection and after review of documentation and interviews with plant l j personnel, the NRC inspector investigated the role of the QA inspectors in the j removal of snubbers and installation of struts. The QA inspectors were tasked with
- verifying the proper snubbers were removed and that struts were correctly installed.
l During QA surveillance 92-0149, an auditor observed that the QA inspectors did
- not appear to understand all the acceptance criteria and yellow line requirements.
The auditor requested that the engineering department provide written clarification l
3 of the yellow line requirements to ensure an adequate QA verification of the l modification was performed. This clarification was provided by memo dated March 16,1993. The inspectors verified that QA had no further problems with this i modification.