MONTHYEARML20155B2621998-10-26026 October 1998 Environ Impact Statement Scoping Process Summary Rept for Calvert Cliffs Nuclear Power Plant,Lusby,Md ML20134C9511996-10-0404 October 1996 Environ Assessment & Finding of No Significant Impact Re Transfer of Control of Operating Licenses Re Plant & ISFSI ML20137B8741985-12-31031 December 1985 Environ Assessment & Finding of No Significant Impact Supporting Amends to Licenses DPR-53 & DPR-69,allowing Use of Hydrogen Purge Line as Operational Containment Vent.Amend Involves NSHC ML20137Z9611985-09-26026 September 1985 Notice of Environ Assessment & Finding of No Significant Impact Supporting Proposed Exemption from Schedular Requirements of App J to 10CFR50 Section III.D.1(a) Re Integrated Leak Rate Test During Insp Outage ML20148A9701978-01-0404 January 1978 Eia Supporting Amends 27 & 12 to Licenses DPR-53 & DPR-69, Respectively 1998-10-26
[Table view] Category:TEXT-ENVIRONMENTAL REPORTS
MONTHYEARML20217P1761999-10-31031 October 1999 Generic Environmental Impact Statement for License Renewal of Nuclear Plants.Supplement 1 Regarding the Calvert Cliffs Nuclear Power Plant.Final Report ML20205E0041999-02-28028 February 1999 Generic Environmental Impact Statement for License Renewal of Nuclear Plants.Calvert Cliffs Nuclear Power Plant.Draft Report for Comment ML20195J7671998-12-31031 December 1998 Semi-Annual Surface Water Withdrawal Rept ML20207A9751998-12-31031 December 1998 Radioactive Effluent Release Rept for Calvert Cliffs Isfsi ML20206K7801998-12-31031 December 1998 Radiological Environ Monitoring Program Annual Rept for Ccnpp,Units 1 & 2 & ISFSI,Jan-Dec 1998. with ML20206C7391998-12-31031 December 1998 Occupational Radiation Exposure Repts for 1998, as Required by Units 1 & 2 Tech Specs 5.6.1 & 6.1 of ISFSI ML20155B2621998-10-26026 October 1998 Environ Impact Statement Scoping Process Summary Rept for Calvert Cliffs Nuclear Power Plant,Lusby,Md ML20236F3451998-06-29029 June 1998 NPDES Noncompliance Notification:On 980615,sample Was Taken & Result Reported That Fecal Coliform Result Was 900 MPN/100 Ml.Result Exceeded Daily Max Limitations.Effluent Was Sampled Again on 980622 & Results Are Expected on 980701 ML20247H6211997-12-31031 December 1997 Radiological Environ Monitoring Program Annual Rept for 970101-1231 ML20237A6421997-12-31031 December 1997 Radioactive Effluent Release Rept ML20212H2721997-12-31031 December 1997 ISFSI Occupational Radiation Exposure Repts for 1997 ML20210Q0971996-12-31031 December 1996 Radioactive Effluent Release Rept,Effluent & Waste Disposal Suppl Info,Second Half of 1996 ML20141A5451996-12-31031 December 1996 Radiological Environ Monitoring Program Annual Rept for 1996, for Calvert Cliffs Nuclear Power Plant,Units 1 & 2 ML20135F0661996-12-31031 December 1996 ISFSI Occupational Radiation Exposure Repts ML20134C9511996-10-0404 October 1996 Environ Assessment & Finding of No Significant Impact Re Transfer of Control of Operating Licenses Re Plant & ISFSI ML20112K0161996-06-18018 June 1996 NPDES Noncompliance Notification:On 960520,BOD5 Results of Sample Taken from Sewage Treatment Plant Effluent Exceeded Daily Max Limitation.Cause of Event Investigated & Unknown. Plant Operations During Period Not Changed ML20078F5481995-01-30030 January 1995 NPDES Noncompliance Rept Notification:On 950111,approx 2,500 Gallons of Suspected Low Concentration Propylene Glycol Solution Discharged to Site Outfall 002 ML20072S3751994-07-25025 July 1994 NPDES Noncompliance Notification:On 940720,plant Intake Embayment Instrumentation Probe Found to Be Not Working. Caused by Saltwater Leakage & Subsequent Damage to Measuring Probe Internals.Equipment Replaced on 940722 ML20072S3441994-07-12012 July 1994 NPDES Noncompliance Notification:On 940706,salinity Meter Found Out of Svc During Surveillance of Effluent Monitoring for Intake Embayment.Caused by Water Leak.Current Monitoring Equipment Being Replaced ML20195J6601994-06-16016 June 1994 NPDES Permit MD0002399,issued to Bg&E ML20072S3601994-06-0707 June 1994 NPDES Noncompliance Notification:On 940601,plant Intake Embayment Instrumentation Oxygen Probe & Data Recorder Found Not to Be Working.Caused by Corroded Internal Connectors & Replacement Tape Cassette Failure,Respectively ML20064G4311994-03-0303 March 1994 NPDES Noncompliance Notification:On 940225,grease & Oil Analysis at 08:00 Was 39.1 Mg/L.Caused by Pavement Runoff Due to Intense Rainfall.Resampling Results Were 0.3 Mg/L ML20063B8231994-01-0707 January 1994 NPDES Noncompliance Notification:On 940104,plant Intake Embayment Dissolved Oxygen Instrumentation Found Damaged. Caused by Failed Oxygen Probe.Probe Repaired ML20064C9941993-12-31031 December 1993 1993 Bg&E Calvert Cliffs Nuclear Power Plant Rept on Number of Personnel & Man-Rem by Work & Job Functions ML20064F1871993-12-31031 December 1993 Effluent & Waste Disposal Semiannual Rept for Second Half 1993, Suppl Info ML20058F2411993-12-0202 December 1993 NPDES Noncompliance Notification:On 931021,trailer That Houses Continuous Monitoring Equipment Removed,Resulting in Failure to Perform Continuous Monitoring of Intake Water. Continuous Monitoring Equipment Returned to Svc on 931117 ML20059B3471993-10-22022 October 1993 Suppl to Environ Rept Calvert Cliffs Nuclear Power Plant ML20056F5691993-06-30030 June 1993 Effluent & Waste Disposal Semiannual Rept for First Half of 1993 ML20012G4191992-12-31031 December 1992 Rept on Number of Personnel & Man-Rem by Work & Job Function for 1992. ML20101S9301992-07-14014 July 1992 NPDES Noncompliance Notification:On 920608,sample Analysis for Fecal Coliform Indicated Concentration of 900 MPN/100 Mi Greater than Max NPDES Limit of 400 MPN/100 Mi.Cause Not Determined.Concentration of Chlorine Increased ML20118A3751992-06-30030 June 1992 Effluent & Waste Disposal Semiannual Rept for First Half 1992 ML20095J2811992-04-24024 April 1992 Suppl to Calvert Cliffs Units 1 & 2 Semiannual Effluent Release Rept for Jul-Dec 1991, Updating Strontium Analytical Results for Fourth Quarter 1991 ML20092G1151991-12-31031 December 1991 Annual Personnel Exposure Rept for 1991, Consisting of Listing of Number of Personnel & man-rem by Work & Job Function ML20092E9851991-12-31031 December 1991 Personnel Monitoring Rept for 1991. W/ ML20090A7941991-12-31031 December 1991 Effluent & Waste Disposal Semiannual Rept,Jul-Dec 1991 ML20104A2461991-12-31031 December 1991 Amended Table 1A,(page 9) from Calvert Cliffs Nuclear Power Plant Effluent & Waste Disposal Semiannual Rept,Jul-Dec 1991, Re Gaseous Effluents - Summation of All Releases ML20141M1241991-12-31031 December 1991 Radiological Environ Monitoring Program Annual Rept for Calvert Cliffs Nuclear Plant Units 1 & 2,1991 ML20091L0301991-12-23023 December 1991 NPDES Noncompliance Notification:On 911216,sample Analysis of Fecal Coliform Indicated Concentration Greater than 1600 mpn/100 Ml Sample,Exceeding Limit.Caused by Sodium Hypochlorite Pump Problems.Chlorine Concentration Increased ML20091L0341991-12-13013 December 1991 NPDES Noncompliance Notification:On 911209,fecal Coliform Analysis Indicated Concentration Greater than 1600 mpn/100 Ml,Exceeding Limit.Caused by Improper Residual Chlorine Analysis.Test Kit Comparator Replaced ML20091L0511991-10-30030 October 1991 NPDES Noncompliance Notification:On 911022,during Electrical Outage No Residual Chlorine Could Be Identified in Routine Weekly Sample.Fecal Coliform Analysis Yielded Concentration Greater That Daily Max Limit.Faulty Breaker Opened Manually ML20082M4641991-06-30030 June 1991 Effluent & Waste Disposal Semiannual Rept for Second Quarter 1991 ML20113G2191991-06-30030 June 1991 Supplement to Semiannual Radioactive Effluent Release Rept, Calvert Cliffs Nuclear Power Plant,First Half 1991 ML20077G9901990-12-31031 December 1990 Updated Tables 1A,1C,2A & 2B Re Gaseous & Liquid Effluents to Semiannual Effluent Release Rept for Second Half 1990 ML20029A7661990-12-31031 December 1990 Semiannual Effluent Release Rept for Second Half 1990. ML20070D3021990-12-31031 December 1990 Number of Personnel & Man-Rem by Work & Job Function & Personnel Whole Body Exposure for CY90 ML20059D2511990-06-30030 June 1990 Semi-Annual Effluent Release Rept for Calvert Cliffs Nuclear Power Plant First Half 1990 ML20058B9071990-06-30030 June 1990 Updated Tables 1C,2A,2B & Page 4 to Semiannual Effluent Release Rept for First Half 1990 ML20091L0611990-01-10010 January 1990 NPDES Noncompliance Notification:On 891218,auxiliary Boiler Blew Down Releasing Approx 6,000 Gallons Auxiliary Boiler Water Into Chesapeake Bay.Monthly Average of 30 Mg/Liter Was Exceeded ML20011F4161989-12-31031 December 1989 Rev 2,to Evaluation Time Estimates within Plume Exposure Pathway EPZ for Calvert Cliffs Nuclear Power Plant. ML20058B9121989-12-31031 December 1989 Revised Page 4 to Semiannual Effluent Release Rept for Second Half 1989 1999-02-28
[Table view] |
Text
.- _
l j .
I 7590-01 UNITED STATES NUCLEAR REGULATORY COMMISSION BALTIMORE GAS AND ELECTRIC COMPANY 00CKETS NOS. 50-317 AND 50-318 NOTICE OF ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT IMPACT The U.S. Nuclear Regulatory Commission (the Commission) is considering the granting of an exemption from certain requirements of Appendix J to 10 CFR Part 50 " Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors." The proposed exemption involves the schedular requirements for the Type A reactor containment Integrated Leak Rate Test (ILRT) as specified in 10 CFR Part 50, Appendix J.Section III.D.I.(a). ,
ENVIRONMENTAL ASSESSMENT Identification of Proposed Action
];
The requirements of Appendix J of 10 CFR Part 50 Section III.D.l(a) state
...a set of three Type A tests shall be performed at approximately equal intervals during each 10-year service period. The third test of each set shall be conducted during the shutdown for the 10-year plant inservice 1
inspection."
The currently scheduled 10-year Inservice Inspection (ISI) outage would be in the fall of 1986 for Unit I and in the spring of 1987 for Unit 2.
Performance of the third ILRT during the 10-year ISI outage which is required i by Appendix J would result in the violation of the 40 10 month interval
! required by Technical Specification 4.6.1.2a. Accordingly, the licensee has requested a change to the ILRT schedule to allow the third ILRT to be conducted earlier than indicated by Appendix J.
mamusmik P
i
2-The Need for the proposed Action:
The granting of the requested exemption from the Type A schedule requirements would allow the licensee to maintain the 40 10 month test interval required by Technical Specification 4.6.1.2a.
Environmental Imoacts of the proposed Action:
Our evaluation of the proposed request for exemption from the Type A test schedule requirements indicates that the exemption will not, in any way, reduce the integrity of the containment systems. Accordingly, post-accident radiological releases will not be greater than previously determined nor dces the proposed exemption otherwise affect radiological plant effluents, and there is no significant increase in occupational exposures. Therefore, the Comission concludes that there are no significant radiological environmental impacts associated with this proposed exemption.
Alternative Use of Resources:
This action does not involve the use of resources not previously considered in connection with the " Final Environmental Statement Relating to Operation of Calvert Cliffs Nuclear Power Plant Units 1 and 2" dated April 1973.
Agencies and Persons Consulted:
The NRC staff reviewed the licensee's request and did not consult other agencies or persons.
FINDING OF NO SIGNIFICANT IMPACT, The Comission has determined not to prepare an environmental impact statement for the proposed exemption.
Based upon the foregoing environmental assessment, we conclude that the proposed action will not have a significant effect on the quality of the human environment.
.' l i For further details with respect to this action, see the application for exemption dated August 15, 1985, which is available for public inspection at the Commission's Public Document Room, 1717 H Street, N.W., Washington, D.C.,
and at the Calvert County Library, Prince Frederick, Maryland.
Dated at Bethesda, Maryland, this 26th day of September,19f 5.
FOR THE NUCLEAR REGULATORY COMMISSION p'O t ,/ Gus C. Lainas, Assistant Director for Operating Reactors Division of Licensing :
Office of Nuclear Reactor Regulation l