U-600253, Forwards Relief Requests & Suppls to Preservice Insp Program Sent on 820223 & 850304 Per SER Confirmatory Issue 67. Justification for Deviating from Requirements of ASME Code Provided

From kanterella
(Redirected from ML20133E864)
Jump to navigation Jump to search
Forwards Relief Requests & Suppls to Preservice Insp Program Sent on 820223 & 850304 Per SER Confirmatory Issue 67. Justification for Deviating from Requirements of ASME Code Provided
ML20133E864
Person / Time
Site: Clinton Constellation icon.png
Issue date: 10/08/1985
From: Spangenberg F
ILLINOIS POWER CO.
To: Butler W
Office of Nuclear Reactor Regulation
References
U-600253, NUDOCS 8510100045
Download: ML20133E864 (14)


Text

, - -

e U-600253 L30- (10-08) 1A.120

/LLINDIS POWER COMPANY -

October 8, 1985 Docket No. 50-461 Director of Nuclear Reactor Regulation Attn: Mr. W. R. Butler, Chief Licensing Branch No. 2 Division of Licensing U. S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

Clinton Power Station Unit 1 Preservice Inspection Program Relief Requests License Condition No. 12 Confirmatory Issue No. 67 The Clinton Power Station (CPS) Safety Evaluation Report (SER)

Section 5.2.4 including Supplements #1 and #2, identified requiremen;;s to identify all requests for relief from impractical ASME Code requirements with supporting justification. This letter submits those relief requests and supplements the Preservice Inspection Program originally sent to you by our Letter U-0422 dated February 23, 1982, and as amended March 4, 1985.

The attached relief requests constitute conditions that were found during performance of Preservice Inspection which require requests for relief. These conditions are as follows: (1) eleven welds located below the surface of the suppression pool, (2) two welds located within wall penetrations, and (3) one weld located underneath component supports. The relief requests specifically identify the welds involved and provide justification for deviating f rom the specific requirements of the ASME Code. Please contact us should you have any questions on this matter.

Sincerely yours, s .

I F. A. S;. nge erg Manager - Licensing and Safety JLP/kaf Attachment ec: B. L. Siegel, NRC Clinton Licensing Project Manager NRC Resident Office Regional Administrator, Region III, USNRC [

Illinois Department of Nuclear Safety 0510100045 051000 PDR ADOCK 05000461 E PDR

,.s._._.______ .

PRESERVICE INSPECTION ,

~ NONDESTRUCTIVE EXAMINATION OF PIPING WELDS l- RELIEF REQUEST ,

i I. Weld (s) Identification:

A.; System: Residuni Heat Renval (RH) l B. Wald Number: 1RH-22-6-2 and 1RI-22-6-4 and associated longitudinal seam f

! C. Piping Line Numbers, .1mI3n l

D. ASME.Section III Code Class: 2 E. Line Size: 12 inches  ;

F. Materials: Staininss steel SA-358 Gr. 304 G. Piping. Nominal Wall Thickness: 0.625 inch R. Function: lhislinedirectsdisclurgefromRHIkeatexchangerinlet relief valve to the suppression pool. *1his line is the last section of piping prior to suppression pool discharge and is open ended.

II. Relief from: -

A. ASME Code Requirements: Er-2100 #nFsrRvTm msnmrinn s B. Reason for Relief 'this lino is an oom onded ninina and thane welds are located below the surface of the sonoression oool. Any leaknoa f'mn the wlds wuld not be detrimmtal to systm operation in maintaining the plant in a cold shutdown or mitigating the consequences of an accident.

C. Alternate Preservice Inspection: None -

f Sketch frce M05-1075 P&lD -

lief Valve f ( ( . Containment Wall ,

1 I Inlet .

? rn .

I k .RH Heat Exchanger A suppression " Line IRH30CA l Pool y 9

-a.- - - _ - ._ - _... .. - . - - - - -

t PRESERVICE INSPECTION NONDESTRUCTIVE EXAMINATION OF PIPING WELDS RELIEF REQUEST I.. Weld (s) Identification:

A.! System: Residual Heat Romnval (Rm B. Weld Number: 1RH-22-6-3 and associated longitudinal seam C. Piping Line Number: 1 RIG 0CA

_ D. ASME Section III Code Class: 2 E. Line Size: 12 inches Carbon Steel - SA 106 Gr. B F. Material: Dissimilar m,terial stainioss sennl - m 1sa cr. 104 CS - 0.500 inch G. Piping Nominal Wall Thickness: SS - 0.625 inch H. Function: This line directs discharge from RH heat exchancer inlet relief valve to the suppression pool. This line is the last section of i

pipirq prior to suppression pool discharge and is open ended.

II. Relief from: -

A. ASME Code Requirements: IWC-2100 PRESERVICE INSPECTION B. Reason for Relief: This line is an open ended piping and this weld is located below the surface of the suppression pool. Any leakage from this weld would not be detrimental to system operation in maintaining the plant in a cold shutdown condition.or mitigating the consequences of an accident.

, C. Alternate Preservice Inspection: Ennn Sketch from M05-1075 P51D Relief Valve

( ( Containment. wall Inlet

'r3 . .

Rllllcat Exchanger A suppression

. . Pool y Line IRIG0CA

-- w, y- . - - ,ee am s omee+ - ~ + .m.e+. ,,-mme-PRESERVICE INSPECTION NONDESTRUCTIVE EXAMINATION OF PIPING WELDS RELIEF REQUEST

1. Weld (s) Identification:

A.l System: Residual Heat Rcmoval 0 01)

B. Weld Number: 1RH-28-6 and issocinted longitudinal seam C.* Piping Line Number: 1RH30CB D. ASME Section III Code Class: 2 E. Line Size: 12 inches Carbon Steel - SA 106 Gr. B F. Material: Dissimilnr m,enrini - Stainless Steel - SA 358 Gr. 304 CS - 0.500 inch G. Piping Nominal Wall Thickness: ss --0.625 inch H. Function: This line directs discharge frcm RH heat exchanger inlet relief valve to the suppressica pool. This line is the last section of pipir(prior to suppression pool discharge and is open ended. See sketch below.

II. Relief from: ,

A. ASME Code Requirements: IWC-2100 PRESERVICE TNSPECPTON B. Reanon for Relief: 'Ihis line is an open ended pining nnd this weld is located below the surface of the suppression pool. Any leaknge from this weld would not be detrimental to systan operation in maintaining the plant in a cold shutdown condition or mitigating the consequences of an accident.

C. Alternate Preservice Inspection: None Sketch Fmn M05-1075 P&ID Relief Valve

( ( -Containment wall Inlet Ril IIcat Exchanger B Suppression

'. Pool y y Line 1RIl30CB

a g

PRESERVICE INSPECTION NONDESTRUCTIVE EXAMINATION OF PIPING WELDS RELIEF REQUEST I. Weld (s) Identification:

A .', S y s t e m : Residual Heat Rcmoval (RH)

B. Weld Number: 1RH-28-6-3 and 1RH-28-6-4 and associated longitudinal seam.

C. Piping Line Number: 11000CB

- D. ASME Section III Code Class: 2 E. Line Size: 12 inches F. Material: Stainless Steel SA-358 Gr.304 G. Piping Nominal Wall Thickness: 0.625 inch H. Function: This line directs discharge from RH heat exchanger inlet relief valve to the suppression pool. This line is the last section of piping prior to suppression pool discharge and is open ended. See sketch below. .

II. Relief from: -

A. ASME Code Requirements: IWC-2100 PRESERVICE INSPECTION B. Reason for Relief: This line is an open ended piping and these welds are located below the surface of the suppression pool. Any leakage from these welds muid not be detrimental to system operation in tinin-taining the plant in a cold shutdown or mitigating the consequences of an accidcut.

C. Alternate Preservice Inspection: None Sketch frcm M05-1075 P&ID Relief Valve Containment Wall x (

V Inlet.

n .

Ril llent Exchanger B Suppression i > ' Pool y Line 1 RIG 0CB

u ., . u. .a_ .a ;.un - -

1 d 1- - l -- -

t' -

PRESERVICE INSPECTION .

{L . N ii

r. NONDESTRUCTIVE EXAMINATION OF PIPING WELDS ,

[ -RELIEF REQUEST \s I.. Weld (s) Identification:

(

A.-System: Residual Hent Removal (RH)

B. Weld Number: 1RH-25-9-3 -

CE Piping _Line! Number:. 1RH02AB \

u DI ASME -Section III Code Class : 2 W X$

x El Line Size: 14 inches- ,'

, , ,q_ J F.1 Material:-' Carbon Steel SA-106 Gr.B L;- 9 sy G.'i. Piping Nominal Wall Thickness: 0.438 inch '

(

,p.,

.1 . <

.H. Function: his is a discharce line of RH pump -B

.j. h,

'4- 'a -

. j. t -

. .t

1

.y ,

l-s II.' Relief'from:

A. ASME Code Requirements: IWC-2100 Preservi'ce Inspection B. Reason for Relief: his weld is located inside the Auxil'iary '

Building wall penetration sleeve number 1AB0011 and is inaccessible to

?; perform any nondestructive examination. .

[ t

?

4:.

' (

- C. ' Alternate .Preservice Inspection:- None '

t. ) N
  • t 1 =

n j: . - g ;. -

II '. ,

,s e -

- .~.. .

_t_.- . . _ _ .

s- u . =:; - - -

=======--- -

= -

+. ,. 2 -

w e ,, .

e .

f& ng

(

l

[ [+

,.4

^ .

y r H>

PRESERVICE INSPECTION Oy
NONDESTRUCTIVE EXAMItATION OF PIPING WELDS
. j$'. g "~

p K" 'i gh,g %g .

RELIEFREQ(UEST. m.J I. Weld (s)2 Identification:

A.(System: NeactorCoreIsolationCooling-(RI)

. x, .

~

B. Weld. Numbed:- 1RI-4-6-2 n.!!.w. ., .

'^ .

!C. Eiping Line Number:

1RIO80 =

m.

r D.lASMEiSection III Code. Class: 2 E.~Line Size: 12 inches' .

i 3

,. , , F. Material: Carbon Steel SA-106 Gr. B w

e i ~%s..

v 4,

{ G..P,iping Nominal Wall' Thickness: 0.500 inch H.' Function: This line prouides an exhaust for RI turbine and diacharnes into the suppr'ession pool.

A II. Relief from:

A. ASME Code Requirements: IWC-2100 Preservice Inspection

+ -

Q c.

(g[1, [,B.ReasonforRelief: This line is an open ended piping and this weld pb -

is located below the-surface of the suppression pool. Any leakage from

. 1,.

this wid would not be detrinental to systen operation. Iater Edition Y of ASFE Fiction XI exonot this wcld from Inservice Insaection (ISI).

I~

Re ~1980 Edition Winter 81 Addenda Subsection IWC-1zzJ (b).

C. Alternate :Preservice Inspections- Nona u

m, le i l'

i I

g.

$I q t .7 ' .

fr 3

'~ ,9 n

, .L . . , . . . - , , , . - , . - - - - . . . , . . _ . . . . .-.,.,,,,-,._,,_n.,.a,..-_,, .,--.,----.,--..,,,n_,._,,.,,.._,,

. = _ - -~ ___ . _ ._ _ __ -

]

PRESERVICE INSPECTION NONDESTRUCTIVE EXAMINATION OF PIPING WELDS RELIEF REQUEST I. Weld (s) Identification:

A. System: Reactor Core Isolation Cooling (RI)

B. Weld Number: 1RI-4-7-2 C. Piping Line Number: 1RIO8C D. ASME Section III Code Class: 2 E. Line Size: 12 inches F. Material: Stainless Steel SA-358 Gr. 304 G. Piping Nominal Wall Thickness: 0.625 inch H. Function: his line provides an exhaust for RI turbine and dis-charges into the suppression pool.

II. Relief from:

A. ASME Code Requirements: IWC-2100 Preservice Inspection B. Reason for Relief: This line is an open ended piping and this weld is located below the surface of the svapression pool. Any leakage from this weld ux:1d not be detrimental to systcm operation. Iater Edition of AfBE Section XI exanne thia weld from Inservice Inspection (ISI) .

Re: 1980 Edition Winter 81 Addenda Subsection IWC-1220(b).

C. Alternate Preservice Inspection: None i:

e D

.~ -

_ . . _ . , u _. . _ -. - .-

p -

l-. _

c b -

lPRESERVICE' INSPECTION L

1 NONDESTRUCTIVE EXAMINATION OF PIPING WELDS

_ ' RELIEF REQUEST.

-I. - Weld (s); Identification:

A.iSystem: Suppression Pool Cleanup and Transfer (SF)

B. Weld Number: ISF-1-1-2 C. Piping Line Number:- ISF02A

- D. ASME Section III Code Class:

4 2

. . E.LineiSide:- 12 inches

}  : F. Material':T Stainless Steel SA 358 Gr. 304 C1. 1

' G. Piping Nominal ~ Wall ~ Thickness:

.. 0.375 inch e

H. Function:g7his line provides a suction from the' suppression pool-j _

for'the SF System.

'II. Relief from:

[ A. ASME Code Requirements: IWC-2100 Preservice Inspection.

B~. Reason for-Relief: This line is an open ended piping and this weld is located below the surface of the suppression pool. Any leakage from this weld would not be detrimental to systen operation. Later Edition of ASE Section XI exannt this ueld from Inservice Inspection (ISI)

Re: 1980 Edition Winter 81 Addenda Subsection IWC-1220 (b)

- C. Alternate Preservice Inspection:- None .

g.

.r-4 0

..F.:a = =

t.. .

i PRESERVICE INSPECTION v-NONDESTRUCTIVE EXAMINATION OF PIPING WELDS RELIEF REQUEST

-1. Weld (s) Identification:

A} System: Sucoression Pool and Transfer (SF)

B. Weld. Number: -TSF-3-4-4 C. Piping Line Number: ISF01G D. ASME Section III Code Class: 2 E. Line Size: 12 inches-Carbon Steel - SA 106 Gr. B F. Material: Dissimilar material - Stainless Steel - SA 312 Gr. TP304

-CS-0.375 inch G. Piping Nominal Wall Thickness: SS -0.375 inch.

H. Function: This line provides a discharge form the SF system into the suooression nool.

II. Relief from:

A. ASME Code Requirements: 11C-2100 Preservice Inspection

- B. Reason for Relief: . This line is an open ended piping and this L weld is located below the surface of the suppression pool. Any leak-i i- age from this weld would not be detrimental to system operation. Later i

f j Edition of ASME Section XI exmpt this weld from Inservice Inspection (ISI).

Re. 1980 Edition Winter 81 Addenda Subsection IWC-1220(b) j c.* Alternate Preservice Inspection: None <

}-

1 f

O ,

- - n_ _

.- a e _ __ . _ _. _

+

PRESERVICE INSPECTION NONDESTRUCTIVE EXAMINATION OF PIPING WELDS RELIEF REQUEST I. Weld (s) Identification:

A. System:- Suppression Pool Cleanup and Transfer (SF)

~

7 B. Weld Number: ISF-3-5-A01 C. Piping Line Number: ISF01G D. ASME Section III Code Class: 2 E. Line Size: 12 inches F. Material: Stainless Steel SA-312 Gr. TP 304 G. Piping Nominal Wall Thickness: 0.375

11. Function: This line provides a discharge from the SF Systen into the sunpressim nool.

6 II. Relief from:

A. ASME Code Requirements: IW,-2100 Preservice Inspection B. Reason for Relief: This line is an open ended piping and this weld

, in inenend boirw the surface of the suppression pool. Any leakage from this weld would not be detrimental to system operation. Later Edition of ASME Secrim XI prormt this weld from Inservice Inspection (ISI) .

RE: 1980 Edition Winter 81 Addenda Subparagraph IWC-1220 (bT.

C. Alternate Preservice Inspection: None 4

+

4 I

y7 m.

A.; System: Drywell Cooling J,

B. Ueld Number: 1VP-6-1-5 C. Piping Line Number: 1VP02BB D. ASME Section III Code Class: 2 E. Line Size: 10 inches F. Material: Carbon Steel SA-106 Gr. B G. Piping Nominal Wall Thickness: 0.365 inch H. Function: This line provides chilled water to the drvwell coolers.

II. Relief from:

A. ASME Code Requirements: IWC-2100 Preservice Inspection B. Reason for Relief: _'Ihis weld is located inside the containment

penetration sleeve number IW107. Later Edition of ASME Section XI ~
code excmpt this weld from Inservice Inspection (ISI). Re
1980 Edition Winter 81 Addenda Subsection IWC-1220(b)

, C. Alternate Preservice Inspection: None

7m. ,_ . _ _ _ . .

PRESERVICE INSPECTION NONDESTRUCTIVE EXAMINATION OF PIPING WELDS RELIEF REQUEST I. Weld (s) Identification:

A.; System: Reactor Core Isolation Cocling (RI)

B. Weld Number: 1RI-13-8AQ1 C. Piping Line Number: 1RIO3C D. ASME Section III Code Class: 1 E. Line Size: 4 inches F. Material: Carbon Steel SA-333 Cr. 6 i

G. Piping Nominal Wall Thickness: 0.438 inch H. Functions. This ifne provides the cooling water to the reactor pressure vessel.

II. Relief from:

A. ASME Code Requirements: IWC-2100 Preservice Inspection B. Reason for Relief: This weld is located underneath of a ccxuponent support and is inaccessible because support is welded and its design does 1

not allow for disassmbly. The rcmoval and reinstallation of this support wuld require grinding and rewelding instead of disassably as found with other supports.

C. Alternate Preservice Inspection: None f

4

7:

[,;.'._,t M Performed under Section III ASME SECTION III ASME SECTION.III WELD NUMBERS

1RH-28-6-2 RT RT 1RH-28-6-3 RT RT & UT Thickness only 1RH-28-6-4 RT RT & UT Thickness only 1RH-25-9-3 RT RT 1RI-4-6-2 RT RT & UT Thickness only 1RI-4-7-2 RT s RT ISF-1-1-2 RT RT t

ISF-3-4-4 RT RT ISF-3-5AQ1 RT RT IVP-6-1-5 RT RT 1RI-13-8AQ1 RT & MT/PT RT, PT & UT Thickness only

  • The weld numbers listed correspond to the weld numbers identified in the relief requests.

NDE - Non Destructive Examination RT - Radiographic Testing UT - ' Ultrasonic Testing PT - Dye penetrar.t Testing i