ADMINISTRATIVE CONTROLS 6.1 RESPONSIBILITY G.1.1 The Vice President of Nuclear Operations
- shall be responsible for overall operation of the units and shall delegate in writing the succession to this responsibility during his absence.
The Vice President of Nuclear Operations *, or his designee, in accordance with approved administrative procedures, shall approve prior to implementation, each proposed test or experiment and proposed changes and modifications to unit systems or equipment that affect nuclear safety.
6.1.2 The Shift Manager shall be responsible for the control room command function. A management directive to this effect, signed by the Group Vice President, Nuclear Production shall be issued annually to all station personnel. During any absence of the Shift Manager from the control room while the unit is in MODE 1, 2, 3 or 4, an individual with an active Senior Reactor Operator (SRO) license shall be designated to assume the control room command function. During any absence of the Shift Manager from the control room while the unit is in MODE 5 or 6, an individual with an active SR0 license or Reactor Operator license shall be designated to assume the control room command function.
6.2 ORGANIZATION 6.2.1 ONSITE AND OFFSITE ORGANIZATION An onsite and an offsite organization shall be established for unit operation and corporate management, respectively. The onsite and offsite organization shall include the positions for activities affecting the safety of the nuclear power plant.
a.
Lines of authority, responsibility and communication shall be estab-lished and defined from the highest management levels through inter-mediate levels to and including all o)erating organization positions. Those relationships shall 3e documented and updated, as appropriate, in the form of organizational charts, functional descriptions of departmental responsibilities and relationships, and job descriptions for key personnel positions, or in the equivalent forms of documentation. These requirements shall be documented in l
the FSAR.
b.
The Vice President of Nuclear Operations
- shall be responsible for l
overall site safe operation and shall have control over those onsite activities necessary for safe operation and maintenance of the
- plant, c.
The Group Vice President, Nuclear Production shall have corporate l
responsibility for overall plant nuclear safety and shall take any measures needed to ensure acceptable performance of the staff in operating, maintaining, and providing technical support to the plant to ensure nuclear safety.
- Duties may be performed by the Plant Manager if that organizational position is assigned.
COMANCHE PEAK - UNITS 1 AND 2 6-1 Unit 1 - Amendment No. Gd4,50 Unit 2 - Amendment No. 36 9606270268 960625 PDR ADOCK 05000445
')
p PDR
9 9
ADMINISTRATIVE CONTROLS ONSITE AND OFFSITE ORGANIZATION (Continued) d.
The individuals who train the operating staff and those who carry out the radiation protection and quality assurance functions may report to the appropriate manager onsite; however, they shall have sufficient organizational freedom to ensure their independence from operating pressures.
6.2.2 UNIT STAFF The unit organization shall include the following:
4 a.
An Auxiliary Operator shall be assigned to each reactor containing fuel and an additional Auxiliary Operator shall be assigned if either unit is operating; b.
At least one licensed Operator for each unit shall be in the control room when fuel is in either reactor.
In' addition, while either unit is in MODE 1, 2, 3, or 4, at least one licensed Senior Operator l
shall be in the control room; A Radiation Protection Technician
- and a Chemistry Technician
- c.
shall be on site when fuel is in the reactor; d.
A site Fire Brigade of at least five members
- shall be maintained on l j
site at all times.
The Fire Brigade shall not include the Shift Manager and the two other members of the minimum shift crew l
necessary for safe shutdown of the unit and any personnel required l
for other essential functions during a fire emergency; e.
Administrative procedures shall be developed and implemented to l
limit the working hours of unit staff who perform safety-related functions (e.g., licensed Senior Operators, licensed Operators, Radiation Protection Technicians, auxiliary operators, and key maintenance personnel).
The amount of overtime worked by unit staff members performing safety-related functions shall be limited in accordance with the NRC Policy Statement on working hours (Generic Letter Nc. 82-12);
l 1
f.
The Shift Operations Manger shall hold a Senior Reactor Operator license; and 1
i i
4 i
i i
- The Radiation Protection and the Chemistry Technicians and Fire Brigade composition may be less than the minimum requirements for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, in order to accommodate unexpected absence, provided immediate 1
l action is taken to fill the required positions.
I COMANCHE PEAK.- UNITS 1 AND 2 6-2 Unit 1 - Amendment No. 44,50 Unit 2 - Amendment No. 36 4