Text

_

l ADMINISTRATIVE CONTROLS i

PROCEDURES AND PROGRAMS (Continued) 9)

Limitations on the annual and quarterly doses to a MEMBER OF i

THE PUBLIC from Iodine-131, Iodine-133, tritium, and all radio-nuclides in particulate form with half-lives greater than 8 days in gaseous effluents' released from each unit to areas beyond the SITE BOUNDARY conforming to Appendix I to 10 CFR 50, and a

i 10)

Limitations on the annual dose or dose commitment to any MEMBER 0F THE PUBLIC due to releases of radioactivity and to radiation from uranium fuel cycle sources conforming to 40 CFR 190.

1 i

f.

Not used.

l g.

Containment Leakaae Rate Testina Proaram A program shall be established to implement the leakage rate testing 3

of the containment as required by 10CFR50.54(o) and 10CFR50, Appendix J, Option B, as modified by approved exemptions. This program shall be in accordance with the guidelines contained in

?

Regulatory Guide 1.163, " Performance-Based Containment Leak-Test Program, dated September 1995".

The peak calculated containment internal pressure for the design j

basis loss of coolant accident, P, is 48.3 psig.

The maximum allowable containment leakage rate, L, at P,, shall be 0.10% of containment air weight per day.

j Leakage rate' acceptance criteria are:

1.

Containment leakage rate acceptance criterion is s 1.0 L l

Duringthefirstunitstartupfollowingtestinginaccor8ance with this program, the leakage rate acceptance criteria are s 0.60 L, for the Type B and Type C tests and s 0.75 L, for Type A tests; l

2.

Air lock testing acceptance criteria are:

}

a)

Overall air lock leakage rate is s 0.05 L, when tested at 2 P,.

b)

For each door, leakage rate is s 0.01 L, when pressurized l

to 2 P,.

The provisions of Specification 4.0.2 do not apply to the test frequencies specified in the Containment Leakage Rate Testing Program, with the exception of the containment ventilation isolation valves, which is specified in Specifications 4.6.1.7.2 and 4.6.1.7.3.

The provisions of Specification 4.0.3 are applicable to the l

Containment Leakage Rate Testing Program.

1 COMANCHE PEAK - UNITS 1 AND 2 6-7 Unit 1 - Amendment No. It,t2,50,51 Unit 2 - Amendment No. 28,36,37 9606270271 960625 PDR ADOCK 05000445 p