UNITED STATES g
NUCLEAR REGULATORY COMMISSION WASHINGTON, o.C. Sh.M
\\*****
TEXAS UTILITIES ELECTRIC COMPANY COMANCHE PEAK STEAM ELECTRIC STATION. UNIT 1 DOCKET N0. 50-445 AMENDMENT TO FACILITY OPERATING LIffjGE Amendment No. 45 License No. NPF-87 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Texas Utilities Electric Company (TU Electric, the licensee) dated January 5, 1996 (TXX-96007),
complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in lo CFR Chapter I; B.
The facility will operate in conformity with the application, as amended, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance:
(1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this license amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment amended to read as(follows:and Paragraph 2.C. 2) of Facility Operating Lice 28"188s M888 6 P
TABLE 3.3-5 REMOTE SHUTDOWN MONITORING INSTRUMENTATION TOTAL NO.
MINIMUM READ 0UT OF CHANNELS INSTRUMENT LOCATION CHANNELS OPERABLE 1.
Neutron Flux Monitors HSP 2
1 2.
Wide Range RCS Temp. - T.
HS.P 1/ Loop 1/ Loop 3.
Wide Range RCS Temp. - T.
HSP I/ Loop 1/ Loop
- l 4.
Pressurizer Pressure
. HSP 1
1 4
5.
Pressurizer Level HSP 2
1 6.
Steam Generator Pressure HSP I/SG 1/SG 7.
Steam Generator Level HSP 1/SG 1/SG 8.
Auxiliary Feedwater Flow HSP 2/SG 1/SG Rate to Steam Generator 9.
Condensate Storage Tank Level HSP 2
1
- 10. Charging Pump to CVCS HSP 1
1 Charging and RCP Seals -
Flow Indication HSP = Hot Shutdown Panel SG - Steam Generator
- The requirements for Minimum Channels OPERABLE for Wide Range RCS Temp.-T remote shutdown indication for Unit 2 are revised to 1/ Loop for three (3) of then four (4) RCS Loops. This revision is to remain in effect until CPSES Unit 2 enters MODE 4 at the beginning of the second refueling outage for Unit 2.
COMANCHE PEAK - UNITS 1 AND 2 3/4 3-43 Unit 1 - Amendment No. 45 Unit 2 - Amendment No.
31
- 8e UNITED STATES p
y NUCLEAR RECULATORY COMMISSION WASHINGTON, D.C. soseH001 s
TEXAS UTILITIES ELECTRIC COMPANY COMANCHE PEAK STEAM ELECTRIC STATION. UNIT 2 DOCKET NO. 50-446 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 31 License No. NPF-89 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Texas Utilities Electric Company (TU Electric, the licensee) dated January 5,1996 (TXX-96007),
complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; 8.
The facility will operate in conformity with the application, as amended, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance:
(1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this license amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 2.C.(2) of Facility Operating License No. NPF-89 is hereby amended to read as follows:
ATTACHMENT TO LICENSE AMENDMENT NOS.45 AND M FACILITY OPERATING LICENSE NOS. NPF-87 AND NPF-89 DOCKET NOS. 50-445 AND 50-446 Replace the following page of the Appendix A Technical Specifications with the attached page. The revised page is identified by Amendment number and contain marginal lines. indicating the areas of change. The corresponding page is I
also provided to maintain document completeness.
I REMOVE INSERT 3/4 3-43 3/4 3-43 l
l l
b
ATTACHMENT TO LICENSE AMENDMENT N05.45 AND 31 FACILITY OPERATING LICENSE NOS. NPF-87 AND NPF-89 DOCKET NOS. 50-445 AND 50-446 Replace the following page of the Appendix A Technical Specifications with the attached page. The revised page is identified by Amendment number and contain i
marginal lines indicating the areas of change. The corresponding page is i
also provided to maintain document completeness.
REMOVE INSERT 3/4 3-43 3/4 3-43 I
I I
I
~-
\\
UNITED STATES g
NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 3000H001 l
TEXAS UTILITIES ELECTRIC COMPANY COMANCHE PEAK STEAM ELECTRIC STATION. UNIT 2 DOCKET N0. 50-446 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 31 License No. NPF-89 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Texas Utilities Electric Company (TU Electric, the licensee) dated January 5,1996 (TXX-96007),
complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; 8.
The facility will operate in conformity with the application, as amended, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance:
(i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; j
D.
The issuance of this license amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment ar4 Paragraph 2.C.(2) of Facility Operating License No. NPF-89 is hereby amended to read as follows:
TABLE 3.3-5 REMOTE SHUTDOWN MONITORING INSTRUMENTATION TOTAL N0.
MINIMUM READOUT OF CHANNELS INSTRUMENT LOCATION CHANNELS OPERABLE 1.
Neutron Flux Monitors HSP 2
1 2.
Wide Range RCS Temp. - T, HS.P I/ Loop 1/ Loop 3.
Wide Range RCS Temp. - T.
HSP 1/ Loop 1/ Loop
- l 4.
Pressurizer Pressure HSP 1
1 5.
Pressurizer Level HSP 2
1 6.
Steam Generator Pressure HSP 1/SG 1/SG 7.
Steau Generator Level HSP 1/SG 1/SG i
i B.
Auxiliary Feedwater Flow HSP 2/SG 1/SG Rate to Steam Generator 9.
Condensate Storage Tank Level HSP 2
1
- 10. Charging Pump to CVCS HSP 1
1 Charging and RCP Seals -
Flow Indication j
l HSP = Hot Shutdown Panel SG = Steam Generator
- The requirements for Minimum Channels OPERABLE for Wide Range RCS Temp.-T remote shutdown indication for Unit 2 are revised to 1/ Loop for three (3) of the n
four (4) RCS Loops. This revision is to remain in effect until CPSES Unit 2 enters MODE 4 at the beginning of the second refueling outage for Unit 2.
COMANCHE PEAK - UNITS 1 AND 2 3/4 3-43 Unit 1 - Amendment No. 45 Unit 2 - Amendment No.
31
Moo p
%o UNITED STATES g
NUCLEAR REGULATORY COMMISSION e
WASHINGTON, D.C. 300eMeet TEXAS UTILITIES ELECTRIC COMPANY COMANCHE PEAK STEAM ELECTRIC STATION. UNIT 1 DOCKET N0. 50-445 AMENDHENT TO FACILITY OPERATING LICENSE Amendment No. 45 License No. NPF-87 3.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Texas Utilities Electric Company (TV Electric, the licensee) dated January 5,1996 (TXX-96007),
complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, as amended, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance:
(1 that the activities authorized by this amendment can be conducted)without endangering the he i
and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this license amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this ifcense amendment and Paragraph 2.C.(2) of Facility Operating License No. NPF-87 is hereby amended to read as follows:
- - -