Amends 55 & 41 to Licenses NPF-87 & NPF-89,respectively, Revising Core Safety Limit Curves & Overtemperature N-16 Reactor Trip Setpoints Based on Analyses of Core Configuration for Unit 2 Cycle 4
ML20212G773
Person / Time
Site: Comanche Peak  
Issue date: 10/30/1997
From: Polich T
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20212G776 List:
References
NUDOCS 9711070091
Download: ML20212G773 (7)


Text

a cen g

l'.

UNITED STATES 3

j NUCLEAR REGULATORY COMMISSION 2

WASHINGTON. D.C. soseH001 i

\\...../

TEXAS UTILITIES ELECTRIC COMPANY COMANCHE PEAK STEAM ELECTRIC STATION. UNIT 1 DOCKET NO. 50-445 AMENDMENT TO FACILITY OPERATING LICENSE i

Amendment No. 55 License No. NPF-87 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Texas Utilities Electric Company (TV Electric, the licensee) dated May 16, 1997 (TXX-97119), complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, as amended, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance:

(1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this license amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all appl':able requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 2.C.(2) of Facility Operating License No. NPF-87 is hereby amended to read as follows:

9711070091 971030

'~

PDR ADOCK 05000445 P

PDR m

4 2.

Technicel Specifications and Environmental Protectica Plan i

The Technical Specifications contained in Appendix A, as revised through Amendment No. 55, and the Environmental Protection Plan contained in Appendix B, both of which are attached hereto, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

The license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION M

Timothy J. Polich, Project Manager Project Directorate IV-1 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Dats of Issuance:

October 30, 1997 s'em e.----

-w.--

_womew w wa ee..._.

w=*==e---we-==-+-=

gutt UNITED STATES g

4

}

NUCLEAR REGULATORY COMMISSION 4

WASHINGTON, D.C. 30MH001 l

'49.....,o TEXAS UTILITIES ELECTRIC COMPANY COMANCHE PEAK STEAM ELECTRIC STATION. UNIT 2 DOCKET NO. 50-446 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 41 License No. NPF-89 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Texas Utilities Electric Company (TV Electric, the licensee) dated May 16, 1997 (TXX-97119), complies with the standards and requirements of the Atomic Energy Act of 1954, as amesided (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, as amended, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance:

(i) that the activities authorized

~by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this license amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 2.C.(2) of Facility Operating License No. NPF-89 is hereby amended to read as follows:

.- d (2) Technical Soecifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No. 41, and the Environmental Protection Plan contained in Appendix B, are hereby incerporated into this license.

TU Electric shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Timothy J. Po ich, Project Manager Project Directorate IV-1 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: October 30, 1997

)

67i 666 x

Unacc eptabie Opera tion 65t x

w 2385 g sig 2

\\

64_-

6 O

5 5 _

N 185 asig S i t' w N N

5r st 60t.

w Acceptab le Operation 59C-58; 0

20 40 60 80 100 120 Percent of Rated Thermal Power FIGURE 2.1-lb UNIT 2 REACTOR CORE SAFETY LIMITS COMANCHE PEAK - UNITS 1 AND 2 2-3 Unit 1 - Amendment No. 14,40, 55 Unit 2 - Amendment No. 36 41 7

SaTETY LfMfTS AND llMITING $A{ETY SYSTEM '5ETTINns t*

L2 11MlUfE SAFETY SYSTEM SETTINGS REACTOR TRIP SYSTEM 1M$TRtfMENTAT10N SETPOIKTS 2.2.1 The Reactor Trip system Instrumentation and Interlock Setpoints shall be set consistent with the Trip setpoint values shown in Table 2.2-1.

APPLICABitTTY: As shown for each channel in Table 3.3-1.

AQ1Qlf:

a.

With a Reactor Trip System Instrumentation or Interlock Setpoint 1ess conservative than the value shown in the Trip setpoint column but more conservative than the value shown in the Allowable Value column of Table 2.2-1, adjust the setpoint consistent with the Trip 5etpoint value.

b.

With the Reactor Trip System Instrumentation or Interlock Setpoint less conservative than the value shown in the Allowable Values column of Table 2.2-1, declare the et.annel inoperable and apply the applicable ACTION statement requirement of Specification 3.3.1 until l the channel is restored to OPERABLE status with its setpoint adjusted consistent with the Trip setpoint value.

i l

-a COMANCHE PEAK - UNITS 1 AND 2

$4 Unit 1 - Amendment No. 41 Unit 2 - Amendment No.27 egg e

9 e

4ewea en + ww y

meyem

-h

  • N.=

_ecumme g

,, a m.

-.e-a.

esa

________m_____

l t

i

}

TABLE 2.2-1 (Continued)

L TABLE NOTATIONS (Continued)

NOTE 1:

(Continued)

ForUnitk (1) for q, - q, between -65% and +7.5%, f,(A q) - 0, where q, and q, are percent RATED THERMAL POWER l in the top and bottom halves of the core respectively, and q, + q, is total THERMAL POWER in percent of RATED THERMAL POWER, for each percent that the magnitude of q - q exceeds -65%, the N-16 Trip Setpoint shall be (ii) automaticallyreducedby0.0%*ofitsvaluea,tRATEDTHERMALPOWER,and l

for each percent that the magnitude of q - q exceeds +7.5%, the N-16 Trip Setpoint shall be l

l l

(iii) automaticallyreducedby2.00%ofitsvaluea,tRATEDTHERMALPOWER.

l ll

  • No setpoint reduction is required for the span of the AI indication.

l l

l NOTE 2:

The channel's maximum Trip Setpoint shall not exceed its computed Trip Setpoint by more than l

3.64% of span for Unit 1 or 1.66% of span for Unit 2.

l l

i el

.I (ly q

l COMANCHE PEAK - UNIT 1 AND 2 2-11 Unit 1 - Amendment No. 11,21.11.49,52,55

}

Unit 2 - Amendment No. 7,21,35,33,41 1

1s