February 20, 1985 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION NOTICE TO COMMISSION, APPEAL BOARD LICENSING BOARD AND PARTIES In the Matter of

)

)

METROPOLITAN EDISON COMPANY

)

Docket No. 50-289 SP

)

(Restart)

(Three Mile Island Nuclear

)

Station, Unit No. 1)

)

Enclosed for the information of the Commission, Appeal Board, Licensing Board and parties are copies of INPO's latest Evaluation of Three Mile Island Nuclear Power Station - Unit One.

The report reflects INPO's evaluation at the end of October, 1984 and bears the date November, 1984; Licensee just received copies of the report from INPO.

~

The INPO determination (Report, at 2) is that:

Basedoon-this evaluation, the team found no reason that, when outage work in progress is completed, TMI-1 should not be ready to be operated safely.

Within the scope of this evaluation, the team deter-mined that THI-l is being maint.ained shut down in a safe manner by qualified personnel.

Included in INPO's evaluation is a section on licensed op-erator training and qualification.

See Report at 21-.

S03 B502220145 850220

=

PDR ADOCK 05000289 G

PDR u

4 INPO makes no findings or recommendations regarding licensed operator training, but particularly notes two areas of Good Practice.

Respectfully submitted,

/((. / /

/ //e/,[4,

Ernest L.

Elake, Jr.,

P.C.

SHAW, PITTMAN, POTTS & TROWBRIDGE 1800 M Street, N.W.

Washington, D.C.

20036 (202)822-1084 Counsel for Licensee Enclosure cc: Service List NOVEMBER 1984 EVALUATION RESTRICTED DISTRIBUTION THREEMILE ISLAND NUCLEAR P0WER STATION UNIT ONE GPU NUCLEAR CORPORATION

-- n _ -

n.,,n,=-,-

--,n:-----,rn a

e s

h y:

,'h' A

P '

.. -5 i

, _;. J

\\

r 4

g P

1 y'

~

4 4

" 'U,

.i r

..s e

v

. I

'Sh'd.e4asswwAm umL5m44he ^-

- AkNSU.h%A*4aakh MU.w+Ma%hi%UI med4M A Nu.w.SM A AkhSedbwJweih4aands.-

v r

. NOTICE: This information was prepared in connection with work sponsored by the Institute of Nuclear Power Operations (INPO). Neither INPO, INPO members, INPO participants, nor any person acting on the behalf of them (a) makes any warranty or representation, expressed or implied, with respect to the accuracy, compieteness, or usefulness of the information contained in this document, or that the use of any information,

. apparatus, method or process disclosed in this document may not infnnge on privately owned rights, or (b) assumes any liabilities with respect to the use of, or for damages resulting from the use of any information, apparatus, method, or process disclosed in this document.

4 r

RESTRICTED DISTRIBUTION EVALUATION of THREE MILE ISLAND NUCLEAR POWER STATION - UNIT ONE GPU Nuclear Corporation l

l l

I Copyright 1984 by Institute of Nuclear Power Operations. All rights reserved. Not for sale.

Reproduction of this report without the written consent of Ifr0 is expressly prohibited. IJnauthor-l

.Ized reproduction is a violation of applicable law.

The persons and organizations that are furnished copies of this report should not deliver or transfer this report to any third person, or make this report or its contents public, without the prior agressent of Ifr0 and the member of Ifr0 for whoe the report was written.

November 1984

/'

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page1

SUMMARY

The Institute of Nuclear Power Operations (INPO) conducted an evaluation of GPU Nuclear Corporation's Three Mile Island Nuclear Pcwer Station Unit One (TMI-1) during the weeks of October 22 and 29,1984. The station is located on Three Mile Island in the Susquehanna River about ten miles southeast of Harrisburg, Pennsylvania. The unit began commercial operation in September 1974 and has been shut down since February 1979.

PURPOSE AND SCOPE INPO conducted an evaluation of site activities to make an overall determination of plant safety, to evaluate management systems and controls, and to identify areas needing improvement. Information was assembled from discussions, interviews, observations, and reviews of documentation.

The INPO evaluation team examined station organization and administration, operations, maintenance, technical support, training and qualification, radiological protection, chemistry, and emergency preparedness. The team also observed the actual performance of j

selected evolutions and surveillance testing. As a basis for the evaluation, INPO used its i

April 1983 Performance Objectives and Criteria for Plant Evaluations; these were applied and evaluated in light of the experience of team members, INPO's observations, and good practicos within the industry.

l INPO's goal is to assist member utilities in achieving the highest standards of excellence in i

nuclear plant operation. The recommendations in each area are based on best practices, rather than minimum acceptable standards or requirements. Accordingly, areas where improvements are recommended are not necessarily indicative of unsatisfactory perfor-mance.

l l

IEsTRICTED DISTRIGUTION l

l Copyright 1984 by lastitute of Nuclear Power Operations. All rights reserved. Not for sale.

(

Reproduction of this report without the written consent of 1990 is empressly prohibited. Unau-thorized reproduction is a violation of applicatate law, f

The porsons and orgenizations that are furnished copies of thIs report shouId not de1Iver or lL transfer this report to any third person, or make this report or its contents putplic, without the

[

prior agreement of 1970 and the member of 10F0 for whom the report was written.

M

=

M 5

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 2 1

DETERMINATION

'iBS A

Based on this evaluation, the team found no reason that, when outage work in progress is completed, TMI-l should not be ready to be operated safely. Within the scope of this i

evaluation, the team determined that TMI-l is being maintained shutdown in a safe manner j

by qualified personnel.

1 di The following beneficial practices and accomplishments were noted:

-=

~~I s

Station personnel are well qualified. Their morale, positive attitude, and motivation continue to reflect commitment to improve performance.

g

_li!

There is a high level of technical expertise among the chemistry, radiological protec-L tion, and maintenance technicians and engineers.

J a

There is an overall improvement in chemistry and in the spare parts warehouse.

5 The Radiological Control Department has established high standards in the area of radiological protection.

Improvements were recommended in a number of areas. The following are considered to be among the most important:

There is a need for more supervisory involvement in the correction of identified Q

deficiencies.

5 The material condition of some balance-of-plant system components needs to be M

improved.

g M

Increased supervisory emphasis is needed on the industrial safety program.

E Findings and recommendations are listed under the PERFORMANCE OBJECTIVES to which J

they pertain. Particularly noteworthy conditions that contribute to meeting PERFOR-4 MANCE OBJECTIVES are identified as Good Practices. Other findings describe conditions M

that detrr.ct from meeting the PERFORMANCE OBJECTIVES. It would not be productive

-3 to. list as Good Practices those things that are commonly done properly in the industry since e

this wouid be of no benefit to CPU Nuclear Corporation or to INPO's other member utili-3 ties. As a result, most of the findings highlight conditions that need improvement, j

a E

The recomr.iendations following each finding are intended to assist the utility in ongoing efforts to improve, all aspects of its nuclear programs. In addressing these findings and

-=

recommendations, the utility should, in addition to correcting or improving specific condi-

-=

tions, pursue underlying causes and issues.

J m

As a part of each station evaluation, the evaluation team follows up on responses to findings

-1 in previous reports. Findings with response actions that are incomplete, but progressing on i

j ';

a reasonable schedule, are carried forward in APPENDIX I to the report. In areas where g

additional improvements are needed, or where response actions have not been timely, a related finding that stands on its own merit is written. Thus, this report stands alone, and 2

reference to previous evaluation 1 reports should not be necessary. For this report, there is i

one finding related to previous Endings and three findings carried forward in Appendix I.

4 A

Y

_9

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 3 The findings listed herein were presented to GPU Nuclear Corporation management at an exit meeting on November 14, 1984.

Findings, recommendations, and responses were reviewed with GPU Nuclear Corporation management on January 28,1985. Responses are considered satisfactory.

To follow the timely completion of the improvements included in the responses and the Appendix I items, INPO requests a written status by August 15, 1985. Additionally, a final update will be requested six weeks prior to the next evaluation.

The evaluation staff appreciates the cooperation received from all levels of GPU Nuc! ear Corporation.

9

'a h

m mm

- mm m um ummmmmum m RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 4 GPU NUCLEAR CORPORATION Response Summary GPU Nuclear appreciates the thorough and comprehensive evaluation of TMI-1. The evalua-tion team provided valuable insights and suggestions for potential improvements. We agree with the evaluation team's findings and recommended areas for improvement as provided in the evaluation report, and think our replies to these findings are responsive and will further enhance our continued efforts to achieve excellence in all phases of operation, mainte-nance, and control at TMI-1. We believe that the underlying reason for the most meaningful findings was the lack of aggressiveness by first-line plant supervisors in implementing and enforcing our established high standards in the areas of radiological controls, industrial safety, and material condition of plant systems and components. As discussed in the responses to the individual findings, considerable action has already been taken to improve in this area. Follow-up to ensure these actions achieve the desired results will be con-ducted, and managers and supervisors will be held personally accountable for their responsi-bilities in this regard.

We consider that the beneficial and good practices noted are further indications of our efforts since the last evaluation to continue to improve safety of operations and to meet our goal of excellence. We are pleased that the evaluation team found no reason that, when ytd]

J,j. M ;

outage work in progress is completed, TMI-l should not be ready to be operated safely and 5 y that TMI-l is being maintained shutdown in a safe manner by qualified personnel. Based on our current projections, outage work in progress should be completed in February 1985, and ff.f V A p. Z..7,p the unit will be ready to restart at that time, awaiting NRC's lifting of the shutdown orders

/

imposed in 1979.

N...

This is TMI-l's third INPO evaluation. All three have been conducted with the plant in the 1:Mi,

  • g.?' ;

cold shutdown condition. Although we have received considerable benefit and implemented worthwhile suggested improvements from these evaluations, we believe further INPO eval-

@. :.f.

uations of TMI-l's programs, performance, and operational capability will be more meaning-

. j W.

ful with the plant in an operating mode. The plant will soon be ready again to operate from e.g 4 a material and operator readiness standpoint and, dependent on the NRC's decision, we hope

& U;[

and expect it will be operating at the time of the next evaluation.

fr{ Q

.m. x may

.d I

f... g

('QT K h

5%),1 f.Q.

if;4.'

x }'.np..;.

M~

k 4. C.

f. 1 bf.e ' y,:' '

._~..c

.W q,1, e..

F...;;.fi; 411 @Q M d

-mm m--

m

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page5 ORGANIZATION AND ADMINISTRATION MANAGEMENT ASSESSMENT PERFORMANCE OBJECTIVE: Management should monitor and assess station activities to improve performance in all aspects of nuclear plant operation.

Good Practice (OA.3-1)

The off-shift management tour program provides an effective

~

means for increasing management presence in the plant.

Management personnel, ranging from foremen to vice president, regularly tour the plant outside normal working hours, some-

=

times in the company of shift personnel. This program contri-butes to good communications between management levels and provides an additional means for identifying areas for improve-ment.

l Finding (OA.3-2)

Departments other than radiological control do not sufficiently support the radiological protection program.

The following i.._- ( f.

deficiencies were noted:

g:. as a.

In the absence of radiological control technicians,

,( c.'.g workers do not always comply with radiological

~ Kj y protection procedures and requirements or use good

/ 3,n.

radiological protection work practices.

3 f %--

.... : : A b.

The Radiological Awareness Report, which is used to

'fy. ; J.y identify both radiological protection problems and 7 4. ":--

good ideas, is not being utilized by operations and J"@ i

'W' maintenance personnel. This does not provide the plant with the benefit of input from experienced Ig/?p..

personnel in improving the radiological protection

%.d program.

'.;..,.~

Mf,9 J c.

Non-radiological protection managers are not identi-

'%. U.

(@y^:

fying radiological protection issues on their back-U; shift manager tours.

Recommendatan Emphasize manager and supervisor accountability for the per-

.h 3 v

i formance of their workers in radiological protection and their Ol;'.:,

~ g..?,

responsibility to identify radiological protection issues. Utilize the back-shift manager tours to identify such issues and to monitor the effectiveness of this program. Expand the use of NQg.,

the Radiological Awareness Report, and encourage its use by all

' p#.f.,

departments.

hjh jr - -.,

,i i Y'-

bi EISH

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

H Page 6 4

Response

Appropriate managers were reinstructed by the Vice President /

Director, TMI-1, and the Operations and Maintenance Director at a special Rad Awareness meeting and at the Site Man,qers meeting en the requirement for and responsibility of all

?

supervisors to enforce good radiological control procedures and

+

practices in all aspects of plant operations and maintenance.

1 This subject will also be discussed with plant Operations /

Maintenance personnel during the Management Interface meetings scheduled to be conducted with each shift during the first six-week training cycle, commencing in January 1985.

Utilization and value of the Radiological Awareness Report i

(RAR) will also be emphasized at these Management Interface meetings, as well as at the Site Managers meeting.

The Manager, Radiological Controls will periodically advise the Vice President / Director and Operations and Maintenance Director on utilization and effectiveness of RARs by other than Radiological Control personnel. All managers involved in the Off Shift Tour Program have been formally instructed to observe for proper radiological control procedures during their tours, and if poor practices are noted, to take immediate on-the-spot corrective e

action. The Vice President / Director will monitor reports of Off Shift Tours to ensure radiological protection issues are being i

adequately assessed.

n 2

INDUSTRIAL SAFETY i

PERFORMANCE OBJECTIVE: Station industrial safety programs should achieve a high degree of personnel safety.

Finding (OA.5-1)

Additional management and supervisory support of the industrial safety program is needed to promote safety awareness and to reduce the number of station accidents and injuries. Areas needing attention include adherence to industrial safety requirements and safe work practices, supervisory enforcement of station policies, and correction of long-standing industrial safety deficiencies.

i Recommendation Increase management and supervisory support of the industrial safety program. Ensure improvement efforts address the defi-ciencies noted in the finding.

Response

The requirement for all supervisors to support and enforce the M

requirements of the Industrial Safety Program was emphasized to all managers at a special Rad Awareness meeting and at the Site Managers meeting. This subject will also be discussed with Operations / Maintenance personnel during the Management

.rw i.mvi m.

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 7 Interface meetings scheduled to be conducted with each shift during the first six-week training cycle, commencing in January 1985. All managers and all personnel participating in the Off Shift Tour Program have been instructed in writing to monitor industrial safety practices routinely and to take immediate on-the-spot corrective action when poor safety practices or viola-tions of safety rules are observed. Those responsible for correc-tion of safety deficiencies have been directed to review all outstanding items to ensure they have been assigned the neces-sary priority and are being engineered / worked as appropriate.

The Vice President / Director receives a monthly progress report on outstanding safety material deficiencies and will monitor this report for progress and initiate necessary actions when needed to improve timeliness in correcting these items. Additionally, on January 1,1985, a formal Safety Recognition Program was implemented with awards recognizing groups and individuals who achieve certain goals related to the reduction of injuries and illnesses.

QUALITY PROGRAMS PERFORMANCE OBJECTIVE: Quality programs should contribute to the effective per-formance of activities important to safety and reliability. Quality programs include quality assurance, quality control, and other programs that provide an independent assessment of plant activities or that function specifically to promote quality of workmanship.

Finding (OA.8-1)

Line management accountability for the quality of some proce-dures needs to be strengthened. Procedure reviews performed by the quality group often identify deficiencies that should have been corrected prior to quality group re. view.

Although this problem has been recognized, insufficient line management action has been taken to improve procedure quality.

Recommendation Emphasize line management accountability for the quality of procedures.

Consider training line supervisors in procedure review techniques used by the quality group.

Response

Management review in conjunction with QA/QC determined that the quality of most procedures as written, and before review by the quality group, was good with the exception of some mainte-nance procedures. A presentation on procedure preparation was conducted by the Plant Review Group Chairman for a majority of key maintenance supervisors and foremen. A repeat session will be held for those supervisors and foremen who were unable to attend.

The presentation covered the procedure owner concept, procedure use, purpose of procedure critique (on job

a RESTRICTED DISTRIBUTION 2

THREE MILE ISLAND (1984)

-5 Page 8 3

i completion), and the purpose of the biennial review, including the use of the required check-off sheet.

All maintenance procedure technical reviewers and procedure owners were made

-y aware that each procedure is to be sufficiently detailed so that a qualified individual can perform the required function without i

direct supervision in accordance with ANSI 18.7 For the next z

two months, senior maintenance management will review all procedure changes and new procedures to monitor that the desired level of improvement in procedure preparation / change /

review'is being achieved. Additionally, at the end of six months,

=

QA/QC will review the QA/QC comments made on maintenance j

procedures / changes submitted for review during that time interval to assess the quality of the initial submittal.

-il

=

FITNESS-FOR-DUTY a

PERFORMANCE OBJECTIVE: The station fitness-for-duty program should identify persons who are unift for their assigned duties or for access to vital areas of the plant as a result of drug or alcohol use, or other physical or psychological conditions, and remove them from such duty or access.

}a Finding (OA.9-1)

Measures to ensure personnel are fit for duty need to be strengthened. The following items were noted:

a.

Many supervisors have not been trained in how to recognize and handle the use of drugs and alcohol.

=

s b.

The company policy on off-duty drug and alcohol abuse refers only to instances involving criminal 3

charges and does not establish a policy against other j

off-duty drug and alcohol abuse.

}

c.

Health and safety information on drugs and alcohol needs to be provided to employees.

1 d.

The company message on drug and alcohol abuse does not address employees whose safety and job could be affected by co-workers unfit for duty.

e.

Closer liaison with local law enforcement agencies is needed in the drug detection effort.

Recommendation Strengthen measures used to ensure personnel are fit for duty, including addressing the items noted in the finding. The "EE!

3 J

Guide to Effective Drug and Alcohol Policy Development"could be of assistance in this effort.

i

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 9

Response

At this time GPU Nuclear is in the process of developing and implementing a program that is designed to cover both fitness for duty and continuous behavior observation. The supervisors' training program has been reviewed twice, and is presently being revised. It is planned for presentation to GPU Nuclear's senior staff in January 1985, with implementation in February 1985.

This training program for all supervisors will include observation of behavior, symptoms of alcohol or drug use, and guidelines on what action the supervisor should take when observations indicate action may be necessary.

The planned program also includes an employee booklet, now in a draft stage, that covers such questions as on-and off-duty drug and alcohol use, safety of other employees, educational information on drugs and alcohol, and a summary of the Employee Assistance Program. The employee booklet should be available to the employees in February 1985.

Liaison with law enforcement agencies will be strengthened in order to assist in monitoring and controlling inappropriate use of alcohol and drugs.

=

3 7

RESTRICTED DISTRIBUTION 7'

THREE MILE ISI. AND (1984)

Page 10 1

d OPERATIONS M

CONDUCT OF OPERATIONS

?

PERFORMANCE OBJECTIVE: Operational activities should be conducted in a manner that achieves safe and reliable plant operation.

i a

~

Good Practice (OP.2-1)

Limiting the plant paging system announcements that can be heard in the control room is effective in reducing overall control room noise level. Channel 3 of the page system has been desig-nated as the operations channel, and only pages made on channel 3 are heard in the control room. The shift foreman can monitor all plant pages with a speaker at his desk.

y PLANT STATUS CONTROLS

(

PERFORMANCE OBJECTIVE: Operational personnel should be cognizant of the status of 2

plant systems and equipment under their control, and should ensure that systems and equip-7 ment are controlled in a manner that supports safe and reliable operation.

5 A

Good Practice (OP.3-1)

The post-relief shift meeting enhances the overall turnover

]

process. The shif t supervisor, foreman, control room operators, and several auxiliary operators meet to exchange information that relates to plant status and shift plans.

j m

E l

'Ea 4

Finding (OP.3-2)

Improvement is needed in the administration of the blue tag 3

clearance program. Blue tags are sometimes used when com-

=

ponent operation is not an integral part of a work effort or 2

associated testing, contrary to the plant procedure. Compo-

.i nents are sometimes not tagged in positions that establish safe t

working conditions and repositioning is necessary prior to start-a ing work. When blue-tagged components are operated, docu-1 mentation of actual component position is not maintained, and a y

review to ensure that safe working conditions are established prior to starting work sometimes does not occur.

1 2

'IE 9

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 11 Recommendation Limit the use of blue tags to only those applications where component operation is an integral part of work or associated testing. Ensure components are tagged in the positions neces-sary to establish safe working conditions. Provide documenta-tion when blue-tagged components are repositicned.

Response

Procedural changes incorporating the recommendations of this finding are in progress and should be issued by March 1985.

Personnel who work with blue tags will be trained on the new procedures by June 1985.

OPERATIONS PROCEDURES AND DOCUMENTATION PERFORMANCE OBJECTIVE: Operational procedures and documents should provide appro-priate direction and should be effectively used to support safe operation of the plant.

Good Practice (OP.5-1)

An effective program has been established to improve graphics in operations and maintenance procedures. The program pro-vides consistent format and improved legibility and enhances procedure usability. Graphs, tables, drawings, and schematics are included in the program.

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 12 MAINTENANCE PLANT MATERIAL CONDITION PERFORMANCE OBJECTIVE: The material condition of the plant should be maintained to support safe and reliable plant operation.

Finding (MA.2-1)

Increased management and supervisory attention is needed to improve the preservation and material condition of plant systems and components. Inadequate implementation of preser-vation and material condition recommendations identified by the preventive maintenance group has resulted in degraded operat-ing capability of some equipment.

Recommendation Implement plant system preservation recommendations to include all items identified as important to plant operation by the preventive maintenance group.

Upgrade the back shif 6 supervisory inspection program to ensure plant systems and components are effectively preserved and material condition is maintained.

Response

Plant system preservation recommendations made by the pre-ventive maintenance group.will be implemented into the Opera-tions Surveillance Program by May 1985. Managers participat-ing in the Off Shif t Tour Program have been directed in writing to monitor plant material conditions during their tours. All on-site managers have also been instructed to tour the plant more frequently in order to observe and identify to responsible super-visors system and equipment deficiencies and potential material problems.

WORK CONTROL SYSTEM PERFORMANCE OBJECTIVE: The control of work should ensure that identified mainte-nance actions are properly completed in a safe, timely, and ef ficient manner.

77 4..

Finding (MA.3-1)

The work control system could be used more effectively to l,,L '

improve the material condition of the plant. Many plant deft-Og,.

Ag ',A ciencies are not documented in the work control system. In addition, a number of job tickets (work requests) have been

.,,1 cancelled without providing adequate feedback to the originator J %:

of the job ticket.

{n',

,.i', i '

(

I'

. [ -i,'

7 3d,*

  • I.,.,

,J,P I_

,/

p6

,f [ ;- Q'

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 13 Recommendation Ensure that material deficiencies are documented and corrected in a timely manner. Consider implementing a deficiency tagging system to aid in deficiency identification. INPO Good Practice MA-301, " Plant Material Deficiency Identification," could be of assistance in this effort. Provide reasons for cancellation of job tickets to the originators.

Response

An improved system for identifying, documenting, and correcting material deficiencies in a timely manner will be in place by July 1985.

INPO Good Practice MA-301, " Plant Material Deficiency Identification," will be used as a guide in developing this system. A change to maintenance procedure 1407-1 will be initiated by April 1985 to require that a copy of cancelled job tickets be returned to the originator.

MAINTENANCE FACILITIES AND EQUIPMENT PERFORMANCE OBJECTIVE:

Facilities and equipment should effectively support the performance of maintenance activities.

Finding (MA.8-1)

Improved controls are needed for in-plant storage of replace-ment parts and materials. Items identified for storage through-out the plant are not included in the warehouse inventory and control system. As a result, usage and inventory information for these parts and materials is not available, and appropriate environmental storage requirements are not being maintained.

Recommendation Reduce in-plant storage of parts and materials where possible.

Establish inventory and environmental controls for in-plant stored equipment.

Response

An inventory of in-plant replacement parts and materials has commenced in order to identify what parts and materials are now stored in the plant. After this inventory is complete, the decision will be made as to which replacement parts and material should remain in the plant under proper inventory control and which should be turned back into the warehouse.

This process should be completed by June 1985. The present plan is to return all parts that require special environmental control to the warehouse.

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 14 TECHNICAL SUPPORT OPERATING EXPERIENCE REVIEW PROGRAM PERFORMANCE OBJECTIVE: Industrywide and in-house operating experiences should be evaluated and appropriate actions undertaken to improve plant safety and reliability.

SOER STATUS The status of Significant Operating Experience Report (SOER) recommendations is as follows:

Number of Recommendations Action Taken 111 Satisfactory 17 Not applicable 32 (2 red tab)

Pending - awaiting decir, ion 10 (no red tab)

Pending - awaiting implementation 0

Needs further review 153 Previously evaluated as satisfactory or not applicable Cumulative Percent of Recommendations with Satisfactory Action Taken:

Plant Industry Average Color Category 96%

89 %

Red 80%

71 %

Other (Yellow and Green)

The following recommendations are pending - awaiting decision:

SOER Number Recommendation Number 81-8 1, 4 82-11 4

82-12 1

83-1 11,14 83-3 4,5,6 83-5 2

83-7 4,5,6 83-9 7, 8 84-1 1,2,3,4,5 84-2 1

84-3 1,2,3,4,5,6 84-4 1,2,3,4,5 iI__...

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984) i Page 15 The following recommendations are pending - awaiting implementation:

SOER Number Recommendation Number 81-5 4

82-8 1

82-11 3

82-13 1, 5, 11 82-15 3

83-9 3,9,10

[

An update on the status of each recommendation listed in the "pending - awaiting decision" or "pending - awaiting implementation" categories shown above is requested in the six-month follow-on response to this report. In addition, the status of each red-tab SOER recommendation received subsequent to this evaluation should be included in the six-month follow-on response. A tabular summary, similar to that above, is requested.

I w.

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

-1

-5E Page 16 NPRDS STATUS

.=

The status of participation in the Nuclear Plant Reliability Data System (NPRDS) is as k

follows:

C4

%=

Engineering Data Reporting Status

$1 3

a.

Date by which data submitted to reflect Complete h

revised NPRDS scope will be completed

_r b.

Number of engineering reports for basic 3450 g

scope submitted to INPO c.

Number of engineering reports ready to N/A 3

submit r

Failure Reporting g

a.

Reports are being submitted in accordance Yes 7

with correct version of scope manual P

r_(

b.

Majority of reports received by INPO within 3 No months of failure discovery J

c.

Degree of failure reporting (reportable High

-[

failures actually reported) ga d.

Quality of failure reports Acceptable j

NPRDS Usage

-g_

a.

Plant personnel trained on remote computer

  • 1 3

searches

-e

=2 b.

Number of searches conducted last three 38

.{

months (Average of most active users - 50)

_g c.

Effectiveness of NPRDS use in improving Minimal 3

plant reliability

=-m c(

  • Unit 2 person 4

m 7

M v

min M%

4

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 17 Good Practice (TS.3-1)

The weekly screening meeting held by the plant analysis section at GPU-Parsippany is an effective means of reviewing operating experience information. Both in-house and industry operating experience are reviewed and discussed by the manager and plant analysis engineers for significance, applicability, and need for further action. After agreement is reached by the plant analysis personnel as to disposition of the operating experience informa-tion, it is then entered on a computer tracking system.

Finding (TS.3-2)

Some in-house events or trends are not included in the operating experience review program. While major transients, scrams, and reportable occurrences receive rigorous investigation, other lesser events, such as mechanical and electrical component fail-ures, chemistry problems, and human error events, are not included in the in-house operating experience review program.

Recommendation Expand the scope of the in-house operating experience review program to include the review of failures and events that, while not major transients, scrams, or reportable occurrences, still have the possibility of degrading plant safety, reliability, or availability.

Response

GPU Nuclear considers that ample systems and review groups are in place to review all events that have the possibility of degrading plant safety, reliability, or availability. The key to implementation of a review program that provides adequate review of all events, not just major or reportable ones, is identification and reporting of these events to the applicable investigation / review groups.

The Manager, Plant Operations will ensure that use of the Incident Reporting System, as described in procedures AP-1029 and AP-1044, is expanded to cover all incidents that did or could affect plant safety, reliability, or availability. Procedure AP-1029 will be revised to include a list of in-house events such as those identified in INPO Good Practice TS-406, " Plant Program for In-riouse Operating Experience Review," as typical of the expanded scope of events that will be included in the TMI-l incident Reporting System.

He will also ensure these reports are distributed to appropriate on-site and off-site operating experience review groups for review and analysis. The Training Department will be provided copies, as determined appropriate, for inclusion in applicable training programs.

Effectiveness of the in-house operating experience review program will be assessed after start-up. The real effectiveness of this program is difficult to evaluate while the plant remains shut down.

s 7

RESTRICTED DISTRIBUTION 7

THREE MILE ISLAND (1984)

Page 18 e

PLANT MODIFICATIONS

'j nI PERFORMANCE OBJECTIVE: Plant modification programs should ensure proper review, control, implementation, and completion of plant design changes in a safe and timely man-j ner.

k Finding (TS.4-1)

Improvements are needed in the utilization of the Plant Temporary Jumper, Link, and Mechanical Modification (TJL &

2 MM) Program. The following problems were identified:

a.

Some temporary modifications have been in effect for extended periods of time.

b b.

Drawings are not revised for temporary modifica-tions that have been in effect for extended periods of time.

c.

Some temporary modifications are not documented

]

under the TJL & MM program.

d.

Items intended for permanent application have been installed under the TJL & MM program.

i Recommendation Upgrade the TJL & MM program to address the items in the finding. The proposed minor modification program should be implemented to preclude the installation of permanent modifi-

-i cations under the TJL & MM program.

Response

Plant Engineering and Operations will jointly review each

)

jumper, lifted lead, and temporary mechanical modification currently in effect to determine those that must be removed for restart and those that should be made documented modifications and be appropriately identified on updated drawings. Those in 2

the latter category will be identified as priority items to the i

appropriate engineering group so that they can be implemented as documented modifications and required documentation and drawing updates completed.

Also, those responsible for the weekly, monthly, and yearly reviews of the jumper, lifted lead, and temporary mechanical modification will be reminded to specifically check for continued applicability.

Additionally, all managers have been reminded that all modifi-cations must be properly documented and approved before installation, and that the TJL & MM program is not to be used as 3

a substitute for the approved and accepted design j

change / modification process.

A design group on site to handle minor modifications, under the 1

direction of the Technical Functions Division, has been approved and funded for 1985. It is expected that this group will be in 1

place and functioning by mid-1985. This group should signifi-i cantly reduce the difficulty and administrative requirements for approval and installation of minor modifications. If successful i

l RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 19 in this endeavor, site operating personnel will gain confidence that needed minor modifications can be engineered and installed in a timely manner and with minimum administrative require-ments.

Finding (TS.4-2)

Improvements are needed in the control of changes to the pro-cess computer scan, log, and alarm functions.

The control process for alarm setpoints is not clearly defined or under-

[

stood. Adequate documentation of alarm changes is not always accomplished.

Recommendation improve the process computer scan, log, and alarm controls by clearly defining requirements and responsibilities.

Controls should address the following items:

a.

, appropriate technical reviews and approvals b.

documentation of the reason for the alarm change c.

documentation of both the new and old alarm set-points d.

expiration dates for temporary changes to alarms e.

revision of applicable procedures

" 'I, ". (

f.

notification of the appropriate computer group for 3

}A., ;..l!,l permanent alarm listings update (l/.- [r t

Response

Procedure changes to address the control of changes to the

' # ! J, process computer scan, log, and alarm functions are in progress and should be issued by March 1985.

]; f3,9 x n. h -

J 9

RESTRICTED DISTRIBUTION 5

THREE MILE ISLAND (1984)

Page 20 C

TRAINING AND QUALIFICATION w

'E TRAINING ORGANIZATION AND ADMINISTRATION U

c PERFORMANCE OBJECTIVE: The training organization and administration should ensure i

effective implementation and control of training activities, j

ACCREDITATION STATUS The status of training program accreditation is as follows:

}

Utility Schedule for N

Program SelRivaluation Reports Status *

=

Operations Area ATV (10/84)

U Shif t Technical Advisor ATV (10/84)

Instrument and Control 6/86 Technician

(=

Electrical Maintenance 6/86 3

Personnel

=::

Mechanical Maintenance 6/86 d

Personnel

'9 Chemistry Technician 6/85 Radiological Protection ATV (10/84)

T Technician

.=

Manager and Technical,

1/86 Staff 3M

-g*-=

2

  • Status of accreditation is indicated as follows:

o Accrediting Board action - ACC (accredited) or DEF (deferred) and date (month / year)

-5 o ATV - indicating an Accreditation Team Visit and date (month / year)

=

o SER -indicating self-evaluation report received and date (month / year)

J o blank - Indicating a lesser progression j

i E

i 5

l RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 21 LICENSED OPERATOR TRAINING AND QUALIFICATION PERFORMANCE OBJECTIVE: The licensed operator training and qualification program should develop and improve the knowledge and skills necessary to perform assigned job functions.

Good Practice (TQ.3-1)

An effective method is utilized for reinforcing and applying basic theoretical engineering concepts.

A basic principles trainer is used in conjunction with detailed training exercise guides to support the demonstration, review, and discussion of basic concepts such as pump fundamentals, fluid flow funda-mentals, thermodynamic laws, vapor and gas laws, and other related engineering principles.

A good instructor-to-student ratio, coupled with detailed training support materials, contri-butes to the success of this approach.

Good Practice (TQ.3-2)

A comprehensive examination control process has been devel-oped and implemented for operator written examinations. This process specifically addresses the issues of examination security and control, examination administration, examination grading, and examination review. The net result is a formal approach to written examinations that helps minimize the possibility of examination compromise.

t

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 22 RADIOLOGICAL PROTECTION RADIOLOGICAL PROTECTION ORGANIZATION AND ADMINISTRATION PERFORMANCE OBJECTIVE:

Radiological protection organization and administration should ensure effective implementation and control of radiological protection activities.

Good Practice (RP.1-1) The effectiveness of the radiological protection program is routinely reported to senior management. This is accomplished through bi-weekly reports to the president of the utility, monthly reports to the board of directors, and monthly reports f

to the vice presidents responsible for operations and radiological protection. These reports describe the plant's performance in personnel exposure, personnel contaminations, numbers and sizes of contaminated areas, number of airborne areas, significant radiological incidents, and problem areas.

Good Practice (RP.1-2)

The Radiological Control Department has high standards in the area of radiological protection.

When Radiological Control technicians observe poor radiological work practices, they consistently provide on-the-spot guidance and corrections.

Radiological Control supervisors and managers routinely observe the performance of both technicians and workers, as well as identify deficiencies in material conditions and housekeeping.

Radiological Control management routinely informs technicians

' j7';

of changes in radiological protection requirements and the T.f resulting expectations in their performance.

1 f-f.,

.y.? :~C Finding (RP.1-3)

The Radiological Investigative Report program is not effectively used in identifying and addressing root causes of radiological incidents.

r Recommendation Establish criteria for an acceptable investigation and report.

Based upon these criteria, provide written guidance and training to supervisors who are likely to perform an investigation of a radiological incident.

e RESTRICTED DISTRIBUTION

~

THREE MILE ISLAND (1984) i Page 23 j

Response

During the first half of 1985, selected Radiological and y

Environmental Control Division and TMI-l managers will attend a summary course on basic system safety that includes root cause analysis of radiological incidents. Based on the results of

=

that training, procedure revision and/or supervisory training will

-i be pursued in order to improve incident investigation and g

reporting. This action is expected to be completed by June 1985.

2; 9

1 i

M EXTERNAL RADIATION EXPOSURE j

=

PERFORMANCE OBJECTIVE: External radiation exposure controls should minimize per-sonnel radiation exposure.

g Finding (RP.4-1)

The present use of alarming dosimeters does not ytsure that i

personnel are able to adequately control their ex7c ares. The following problems were identified:

a.

Alarm setpoints are not always established.

b.

Workers are not always aware of the alarm setpoint.

c.

Workers do not periodically read the alarming dosi-Q meter to monitor their exposure.

=

Recommendation Provide guidance to Radiological Control technicians in estab-g lishing alarm setpoints for routine and non-routine work.

Instruct workers on the use of alarming dosimeters, including the need to monitor their exposures and the need to know the E

alarm setpoint. Emphasize the purpose and use of the alarming dosimeter during the radiation worker initial and retraining programs.

Response

By Standing Order, every alarming dosimeter issued now has an j

alarm setpoint established. This requirement, as well as the j

requirement for the issuer to inform the user of the alarm 9

setpoint, will be formally proceduralized by March 1985. The purpose and use of the alarming dosimeter, including the neces-sity to periodically read the dosimeter, will be reemphasized in i

radiological worker training / retraining commencing in January 2

1985.

5;ll E

5 W

m 1

i

=9 RESTRICTED DISTRIBUTION P

THREE MILE ISLAND (1984) d Page 24 7

21f, CHEMISTRY CHEM 5TRY CONTROL e'

PERFORMANCE OBJECTIVE: Chemistry controls should ensure optimum chemistry condi-tions during ali phases of plant operation.

_{e Finding (CY.3-1)

Operation and performance monitoring of the makeup water g

plant need improvement. The following problems were noted:

J a.

Mixed bed effluent data are indicative of occasional k

low level contaminant leakage.

b.

The conductivity limit of 0.95 micromho/cm for mixed bed effluent is not consistent with best industry practices.

c.

Mixed bed effluent limits for chloride, sodium, and sulfate do not ensure minimum contaminant ingress i

to plant systems.

(

d.

Grab sample analyses for mixed bed effluent con-ductivity are not consistent with the in-line monitor.

_g e.

Chemical analyses of the effluent are only per-d formed at 80 percent completion of the demineralizer bed run cycle.

15 Recommendation Improve the operation and monitoring of the makeup water h

plant.

Reduce the mixed bed conductivity limit to 0.1

'E micromho/cm. Lower the allowable effluent limits for chloride, sulfate, and sodium consistent with Steam Generator Owners' Group feedwater recommendations. Utilize a flow-through cell

=

and portable meter in place of the grab sample. Periodically 5

analyze and trend effluent contaminant levels at the beginning

-.=

and end of the bed run cycle to estab!!sh baseline and perfor-mance information.

E

Response

Operational limits and grformance monitoring of the makeup water plant will be revLewed to address the problems noted in f

the finding. The upper conductivity limit for the makeup water system will be reduced to a level consistent with the water quality expected in the condenser hotwell. Conductivity of the makeup water system will be measured and recorded each shift using the in-line monitors. Effluent monitoring of the makeup 3

water system will be conducted daily. This review and resulting changes in chemistry controls will be implemented by February 1935.

e 92 u mm

k 2

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 25 Finding (CY.3-2)

Some chemistry limits in the computer data management system 5

are not consistent or appropriate for present plant lay up/ shut-down conditions. In addition, limits for the condensate storage

=

tank do not ensure minimum contaminant ingress to secondary c

and related auxiliary systems.

Recommendation Perform an evaluation of limits presently in effect. Provide

(

limits that are meaningful for daily detection of undesirable r esults.

m

~~

Response

The computer data management system's limits were consistently more conservative than the limits established in the water chemistry specifications. This resulted in mere out-of-4 specification indications as identified by the computer than actually existed.

The computer limits for some auxiliary 4

systems had been established based on requirements of an operating power plant condition. Actions had been underway at the time of the evaluation to update computer limits for the existing plant conditions.

This update will be continued to m

minimize differences between the computer limits and corrective action limits, regardless of plant conditions. In the a

case of the condensate storage tank, computer limits have been changed to help ensure that low level contamination of the contents of the tank are identified in a timely manner so that contaminant ingress to the secondary and related auxiliary systems can be minimized.

7 i

LABORATORY ACTIVITIES PERFORMANCE OBJECTIVE:

Laboratory and counting room activities should ensure accurate measuring and reporting of chemistry parameters.

Finding (CY.4-1)

Certain analysis techniques and practices do not ensure the most accurate results. Grab samples from the stator cooling system result in lower pH and higher conductivity values than would actually be expected. In addition, reported limits for sodium, chloride, and sulfate are not consistent with the actual detec-

=

tion limits for the respective laboratory instruments.

Recommendation Evaluate the present method for analyzing the stator cooling system and other high purity water samples. Consider recording in-line stator cooling conductivity meter values in lieu of grab sample results. Record the actual analytical results for sodium, chloride, and sulfate, consistent with the analytical detection limits, to allow low-level trending of these impurities.

Response

A review has been made of TMI-l water systems to evaluate the appropriateness of conductivity and pH analysis methods.

}

I RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)'

Page 26 With the exception of the stator cooling system and the makeup water systems, all the systems have chemical additives (there-fore are not high purity water systems) or are open to the atmosphere (condensate storage tank and demineralized water storage tanks). Grab sample analyses run for the stator cooling and the makeup water systems had been performed as a rough backup to on-line instrumentation. In the future, the indicators and recorders for these two systems will be reviewed by a chemistry technician once per shift, and appropriate data will be recorded in lieu of performing conductivity and pH grab sample measurements. Periodically, the pH and conductivity measuring devices will be checked by comparing results against flow cell samples taken in parallel with the flow that is monitored..This process will be initiated by the end of January 1985.=

Plant Chemistry will evaluate the existing detection limi:s for impurities and reduce the reported detection limits where appropriate.

This will result in recording analytical results consistent with the actual analytical detection limits, thus allowing low-level trending of subject impurities. This action will be completed by February 1985.

Finding (CY.4-2)

Apparent voltage fluctuations are causing variation in effi-ciencies for the gross beta-gamma counters and liquid scintilla-tion counter in the counting room.

Recommendation Investigate and correct the cause of this problem.

Response

Variations have been recognized in the efficiencies of the iden-tified radiochemistry counting equipment for the past nine months, and work has been ongoing during that period to identify the cause and correct the problem. These actions include use of a voltage controller, installation of an alarm to indicate AC power fluctuations, and monitoring of line voltage. Because of the quality control checks run with each batch of samples, the variations in efficiency have not led to the reporting of erroneous results.

Plant Engineering is currently conducting a review of the power supply for these instruments. Appropriate corrective actions will be taken when the cause of the problem is identified.

(

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 27 CHEMICAL AND LABORATORY SAFETY PERFORMANCE OBJECTIVE: Work practices associated with chemistry activities should ensure the safety of personnel.

Finding (CY.5-1)

The safety program for handling certain bulk chemicals in the plant needs improvement. Some problem areas noted are as -

follows:

a.

Hydrazine, sodium hydroxide, and sulfamic acid are handled using open transfer containers.

b.

An eyewash or safety shower is not present in the vicinity of the domestic water chlorination system.

c.

L c.

Spray protection is needed in the walkway near the water treatment acid and caustic transfer pumps and -

lines.

d.

Operation procedures do ' not adequately address chemical handling safety concerns.

Recommendation Eliminate the safety concerns noted above. Ensure that appil-cable personnel are aware of the requirements for handling hazardous chemicals.

Response

The following actions address this findings a.

The direct handling of hydrazine and sodium hydroxide in open containers has been eliminated.

Sulfamic acid is no longer used and will be removed from the plant in January 1985.

b.

An eyewash station will be installed in the vicinity of '

the domestic water chlorination system by February 1985.

c.

The need for spray protection in the walkway near the water treatment acid and caustic transfer pumps and lines has been reviewed, and it was determined that the system operating pressure and the moat design are such that protection is not practical or justifiable.

d.

Plant operating procedures dealing with chemical handling will be reviewed in regard to safety con-cerns and will be upgraded, as appropriate, by March 1985.

i RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 28 RADIOACTIVE EFFLUENTS PERFORMANCE OBJECTIVE: Radioactive effluent controls should minimize radioactivity released to the environment.

Good Practice (CY.6-1)

An effective quality control program is in place to help ensure accurate determination of radionuclides in batch releases. In addition, performance of the waste evaporator cleanup system is aggressively monitored in order to minimize effluents.

e

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

Page 29 EMERGENCY PREPAREDNESS EMERGENCY ASSESSMENT AND NOTIFICATION PERFORMANCE OBJECTIVE: Emergency maeument and notification procedures should enable the emergency response organization to correctly classify emergencies, assess the consequences, notify emergency response personnel, and recommend appropriate actions.

Finding (EP.5-1)

The equipment and methods used to obtain a post-accident sampling system (PASS) reactor coolant liquid sample do not minimize radiation exposures for personnel who must obtain the sample. Problems identified are as follows:

a.

Sample volume is greater than that needed for analysis of a single sample.

b.

The leaded glass shield placed on the sample sink is not large enough to adequately shield the person drawing the sample.

c.

The sample bottle must be closed by hand (screw-on lid) after the sample is drawn.

d.

Several valves are not properly labeled (CA-V317, CA-V26 A, B, C).

e.

The location of temperature gauge CA4 TI is in-correctly stated in the PASS sampling procedure (1004.15).

Recommendation Analyze equipment and methods used to obtain a PASS reactor coolant liquid sample.

Provide system improvements for problem areas noted above in order to minimize personnel exposure.

Response

An analysis of the equipment and methods used to obtain a PASS reactor coolant liquid sample will be conducted by June 1985.

This analysis will include a review of and corrective actions as appropriate for the specific problems noted in the finding and will specifically concentrate on areas of improvement to mini-mize personnel exposure.

l

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

APPENDIX I Page1 APPENDIX I Summary of Outstanding Response Action from Previous Evaluation (1983)

DOCUMENT CONTROL Finding (OA.6-1)

Vendor achnical manual content, distribution, and use are not rigorously controlled. Some manuals marked " Controlled Copy" were noted in the plant without evidence of proper control.

Some maintenance procedures refer to portions of technical manuals for detailed work instructions even though the refer-enced po.tions have not been reviewed for technical adequacy.

Recommendation Establish improved control of vendor technical manuals to ensure they are complete and current. Ensure that portions of manuals used to control work are technically adequate.

Response

A list of about 60 technical manuals, which were considered to be the most important for plant operation and maintenance, has t

been selected for priority review and updating, including vendor j.'Q participation as required. The revised manuals will be issued as

@f).]

"contralled documents" using the normal document control (i,9 system. This is a long-term project that may take two years to

.M. i.

complete.

Procedures are in place for the control of these

. fr '~;

manuals. All manuals that are currently in the plant will be L~ 'M stamped "for information only." As controlled copies from the 9f(

initial list of 60 manuals are received, additional manuals will be B. 4.-l selected for review and upgrading as part of this continuing

, f t..

program. When a manual has been issued as a controlled docu-

%.w

.p%

d ment, all "mformation only" copies of that manual will be purged from the plant.

i..t

... N. 5 Maintenance Procedure 1407-1, Corrective Maintenance, will be g';

revised by November 1983 to require that an engineering review Q }hg be conducted of the applicable portions of technical manuals Q

whenever technical manuals are used to control work.

m:9 Status To date, approximately 20 technical manuals have been issued as O

controlled documents. Manuals not yet in the control system

$ t.

have been marked "for information only." This effort to control b ;.1 manuals important to safe and reliable plant operation is con-

.z.g.

tinuing.

4p.z

?. y...

Maintenance Procedure 1407-1, " Corrective Maintenance," has

%R-been revised to require engineering review prior to use of any T.i; manual that is not yet controlled, when that manual is used to

%d obtain technical information such as torque values, dimensions,

$@.y tolerances, and types of lubricants.

7 Q.y AM When manuals are used directly in performing work, reviews appropriate for procedures are performed on applicable techni-cal manual information. In many instances, the ir. formation is included directly in the procedure.

RESTRICTED DISTRIBUTION 4

THREE MILE ISLAND (1984) u--

APPENDIX !

~

Page 2 In addition to the above actions, consolidated administrative guidance in this area is planned. A station administrative pro-cedure for the use and control of technical manuals is expected to be developed and implemented by March 1985.

NON-LICENSED OPERATOR TRAINING AND QUALIFICATION Finding (TQ.2-1)

A training program for middle-level managers in plant systems and technology is needed. Currently, such courses exist for individuals at the operator / technician level and at the senior management level. However, individuals in positions between these levels receive no such training.

Recommendation Provide plant systems and technology training to middle-level managers.

Existing programs for personnel at operator / technician levels and/or senior management levels could be utilized in this effort.

Response

TMI agrees that a formal training program for middle-level managers in plant systems and technology is needed. A specific course on pressurized water reactor (PWR) systems and tech-nology is under development and is scheduled to be available in July 1982. Attendance at this course, or portions thereof, will be determined on an individual basis taking into consideration the background, work assignments, and professional development objectives of the individual employee.

Status The TMI-l Managers Technical Training Program Course is in the final review stages after delay due to other higher priority efforts.

Course and lesson. objectives have been written.

Delivery of the f,irst session of the course is planned for February 1985.

TRAINING FACILITIES AND EQUIPMENT Finding (TQ.9-1)

Improvements are needed in the reference and study material available for use in systems training. Existing system descrip-tions are out of date. The plant is aware of this situation, and an Operations Plant Manual is being written to provide updated system descriptions.

RESTRICTED DISTRIBUTION THREE MILE ISLAND (1984)

APPENDIX I Page 3 Recommendation Complete the development of the Operations Plant Manual.

Implement a process to ensure that the newly developed material will be kept updated to reflect system modifications.

Response

The Operations Plant Manual is scheduled to be completed by January 1984. A specific individual has been assigned as coordi-nator for this manual, with an individual " owner" assigned to each section. It will be the owner's responsibility to review periodically and update his/her section of the manual in accord-ance with a specific schedule. Individuals using the manual can recommend changes, as appropriate, by simply contacting the owner of the section involved. Updates required due to modifi-cations to plant equipment / systems will be formally controlled through Administrative Procedure 1043, Control of Plant Modifications.

Status All sections of the Operations Plant Manual have been written in at least draft form. The manual is now about 93 percent com-plete and is planned to be completed by March 1985.


um

n

.g O

e e

e suessemi wie en sie ympie Wsees esse e siemenew. se veer Aieme,af%mt aFeme mfleeWWsieb% AsW'Wewie-M

.e espasseseeepsised seewruesomenesteesmusenemeneersee 9pOeseemershoossesey essee.

e escenesseteressed messessommemmessessempensasseneseereespegue eyes eegeustsseesensumessesese-s yeygeesesiegewgeWcase oper eassensgagst yesaganaseyeeseemum pieuesiesepseduee _ _ __ _. emp M 4erudyAsp#sete8WesteseyWsip.. __ _

Nepasisse oftesW ee ese W epousease wegey eseessee eem -

Assetesse GeenW tese tsusessiere Osamewey 800 Cenessee Asesess EPs to usessem speemese 37est N sensaem M

essese put taleW ftse 4WeeCaseW Peeere Repassene AeneyW eteappeessemay se seennes se asemeer er esesig M e me seesus puer assee Pueens aU $ &

INPg RESTRICTED DISTRIBUTION institute of w

Nuclear Power Operations 1100 Circle 75 Parkway Suite 1500 Atlanta, Georgia 30339 Telephone 404 953-3600 t

l h

{

l s

s

-.y e v,

?

D.'--

3 >N7N-Y. M,D7

  1. 'r"-=

i---

N'

[

5 NM

-A.

+ ^

n:

1%,

y./ -

., I-(

f

^

^

A~

m 1

3

-i

~

l-[*?

?

- +

~

g-

.g;

~ *

..u s

g

s. J 4...

/

,C

" %wws.a&4d.wS 54M;%WW ksaan -'

4 a.CoiaAemi:'

- +-

r

'W,-

9, UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION

'BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In'the Matter

)

)

METROPOLITAN EDISON COMPANY

)

Docket No. 50-289 SP

)

(Restart Remand on Management)

(Three Mile Island Nuclear

)

Station, Unit No. 1)

)

SERVICE LIST Nunzio J. Palladino, Chairman Administrative Judge U.S. Nuclear Regulatory Commission John H. Buck Washington, D.C.

20555 Atomic Safety & Licensing Appeal Board

. Thomas M. Roberts, Commissioner' HU.S. Nuclear Regulatory Commission-U.S. ~ Nuclear Regulatory Commission Washington, D.C..

20555

- Washington,'D.C.

20555 Administrative Judge James K. Asselstine, Commissioner Christine N. Kohl U.S.. Nuclear Regulatory; Commission Atomic Safety & Licensing Appeal Washington, D.C.

20555 Board U.S. Nuclear Regulatory Commission Frederick Bernthal, Commissioner Washington, D.C.-

20555~

' U.S. NuclearcRegulatory Commission Washington, D.C.

'20555

-Administrative Judge Ivan W.

Smith, Chairman iLando W.

Zeck, Jr., Commissioner Atomic Safety & Licensing Board U.S. Nuclear Regulatory Commission U.S. Nuclear Regulatory. Commission Washington, D.C.

20555 Washington, D.C.

20555

' Administrative Judge Administrative-Judge Gary J. Edles, Chairman Sheldon J. dolfe-Atomic Safety & Licensing Appeal Atomic' Safety & Licensing. Board Board

. U.S. Nuclear Regulatory Commission U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Washington, D.C.

20555 y-

-t a

' Administrative Judge Mr. Henry D. Hukill Gustave A. Linenberger, Jr.

Vice President Atomic Safety & Licensing Board GPU Nuclear Corporation U.S. Nuclear Regulatory Commission P.O. Box 480 Washington, D.C.

20555 Middletown, PA 17057 Docketing and Service Section (3)

Mr. and Mrs. Norman Aamodt Office of the Secretary R.D.

5 U.S. Nuclear Regulatory Commission Coatesville, PA 19320 Washington, D.C.

20555 Ms. Louise Bradford Atomic Safety & Licensing Board TMI ALERT Panel 1011 Green Street U.S. Nuclear Regulatory Commission Harrisburg, PA 17102 Washington, D.C.

20555 Joanne Doroshow, Esquire Atomic Safety & Licensing Appeal The Cnristic Institute Board Panel 1324 North Capitol Street U.S. Nuclear Regulatory Commission Washington, D.C.

20002 Washington, D.C.

20555 Lynne Bernabei, Esq.

G V*r ment Accountability Jack R.

Goldberg, Esq. (4) r Office of the Executive Legal 2.555 Connecticut Avenue Washington, D.C.

20009 U.S Nuc ear Regulatory Commission Washington, D.C.

20555 Ellyn R. Weiss, Esq.

Harmon, Weiss & Jordan

-Thomas Y. Au, Esq.

2001 S Street, N.W.,

Suite 430 Office of Chief Counsel Washington, D.C.

20009 Department of Environmental Resources Michael F. McBride, Esq.

i 505 Executive House

'LeBoeuf, Lamb, Leiby & MacRae P.O. Box 2357 1333 New Hampshire Avenue, N.W.

Harrisburg, PA 17120 Suite.1100 Washington, D.C.

.20036 Michael W.

Maupin, Esq.

William T. Russell Deputy Director, Division Hunton & Williams 707 East Main Street of Human Factors Safety Office Of NRR P.O. Box 1535 Mail Stop AR5200 Richmond,-VA 23212 U.S. NRC Washington, D.C. 20555 l-1 i

I l

t t

_