Plant Unique Analysis Rept,Vol 6,Unit 1 Torus Attached Piping & Suppression Chamber Penetration Analysis
ML20072N925
Person / Time
Site: Dresden, Quad Cities, 05000000
Issue date: 05/31/1983
From: James Gavula, Pandey P, Wallach G
NUTECH ENGINEERS, INC.
To:
Shared Package
ML17194B616 List:
References
COM-02-039-6, COM-02-039-6-R00, COM-2-39-6, COM-2-39-6-R, NUDOCS 8307180179
Download: ML20072N925 (176)


Text

{{#Wiki_filter:(3 COM-02-039-6 D) Revision 0 May 1983 27.0200.1200 QUAD CITIES NUCLEAR POWER STATION UNIT 1 PLANT UNIQUE ANALYSIS REPORT VOLUME 6 TORUS ATTACHED PIPING AND SUPPRESSION CHAMBER PENETRATION ANALYSES Prepared for: Commonwealth Edison Company Prepared by: NUTECH Engineers, Inc. San Jose, California Approved by: g7-A., k M P. Pandey N. A.

McClean, P.E.

Pro'ect Leader Engineering Manager M G. Wallach T. W. Soo Hoo, P.E. Project Leader Engineering Manager ~ t w., sd kw f/. A.~ Gavula, P.E. J. D. Muffett, P. E '. ' Pr)ojgLtEngineer /rA Engineering Manager 1 )X t H. L. Gustin, P.E. Dr. L. C. Hsu Project Engineer Engineering Manager i Issued by: lid [o) T/ J. Victorine, P.E. R., H. Buchholz 's / Project Manager Project Director [kh0C O P

REVISION CONTROL SHEET O TITLE: Quad Cities Nuclear Power Station REPORT NUMBER: COM-02-039-6 Unit 1, Plant Unique Analysis Revision 0 Report, Volume 6 T. J. Victorine/ Project Manager INITIALS A. G. Brnilovich/ Project Manager ( INITIALS b A. K. Moonka/Proiect Manager INITIALS INITIALS INITIALS '~ INITIALS INITIALS EFFEC-EFFEC-PRE-ACCURACY CRITERIA TIVE REV ~ TIE REV PARED CHECK CHECK PARED CHECK CHECK P AGE (S) PAGE(S) 6-Lx 0 W (llKM through 6-xix 6-1.1 %h bd U T c o QEP-00*.4-00 ) 6-ii nutggh

REVISION CONTROL SHEET O TITLE : Quad Cities Nuclear Power Station REPORT NUMBER: COM-02-039-6 Unit 1, Plant Unique Analysis Report Revision 0 Volume 6 P. Pandey/ Consultant I INITIALS N. Jafarey/ Consultant I N1 INITIALS S. R. Farahani, P.E./ Associate Engineer s R.F INITIALS N. A. McClean, P.E./ Engineering Manager INITIALS INITIALS %/ INITIALS INITIALS PRE-ACCURACY CRITERIA b[..h~ PRE-ACCURACY CRITERIA b5f.h ~ ggy R.. Pkdi.s) PARED CHECK CHECK {j{ gg) PARED CHECK CHECK 6-2.1 0 6-2.14 0 YY.2Y ORY Ak h f_[9 SQF ff

2. '7hs.

S* 6-2.5 NJ /ag 6-2.29 6-2.6 71 M. through 6-2.7 gT pp 6-2.31 MT M 6-2.8 M 'J AF 6-2.32 6-2.9 ~h.'7hn. through y 7, gjg, 6-2.34 6-2.10 71, Wir. 6-2.35 6-2.11 i y I through through g 6-2.13 Y SRF Nr g; 6-2.40 Y 0 0 QEP-001.4-00 6-iii nutggb

REVISION CONTROL SHEET (Continued) TITLE: Quad Cities Nuclear Power Station, REPORT NUMBER: COM-02-039-6 Unit 1, Plant Unique Analysis Revision 0 Report, Volume 6 i PRE-ACCURACY CRITERIA PRE-ACCURACY CRITERIA E REV E REV PARED CHECK CHECK PARED CHECK CHECK PAGE (S) PAGE(S) 6-2.41 0 S R.F gp ~)), A, 6-2.42 ~21 3 S, 6-2.43 HT 88 6-2.44 ff ?). 712c_, 6-2.45 ff "?? ?n s - 6-2.46 NT PF 6-2.47 NJ fr 6-2.48 through 8 2 M-6-2.51 6-2.52 NT /2p 6-2.53 l through

  1. g 6-2.77 2 WIG.

6-2.78 N7

  1. 8 6-2.79 ff

?)a7Ms. O 6-2.80 Y

  1. f
71. > rs, 6-2.81 Y

SRF H7 g l QEP-001.4-00 6-iv nutggb

REVISION CONTROL SHEET (m TITLE: Quad Cities Nuclear Power Station REPORT NUMBER: COM-02-039-6 Unit 1, Plant Unique Analysis Revision: 0 Report, Volume 6 J. A. Gavula, P. E. /Encrineer MNITIALS J. E. Neurauter,P.E./ Engineer \\ ( fl IQ4ITIALS INITIALS INITIALS INITIALS INITIALS INITIALS f EFFEC- ~ PRE-ACCURACY CRITERIA PRE-ACCURACY CRITERIA ^ ^ (S) (S) l' l-3.13 0 9 9 3 6-3.1 0 6-3.2 l-3.14 6-3.3 1-3.15 6-3.4 1-3.16 pg en tai 1:!:l; p Sn !ps 6-3.7 C U 1-3.19 v 6-3.8 1-3.20 e 6-3.9 l-3.21 0 6-3.10 6-3.11 Y 6-3.12 0 s s a (N CI?-001.4-CC 6-v nutggb

j REVISION CONTROL SHEET O TITLE: Quad Cities Nuclear Power Station REPORT NUMBER: COM-02-039-6 Unit 1, Plant Unique Analysis Revision 0 Report, Volume 6 T. W. Soo Hoo/ Principal Engineer 7/g)$ INITIALS G. S. Wallach/ Consultant I INITIALS E. V. Harlow/ Consultant I INITIALS INITIALS INITIALS CRITERI A l EFFEC-EFFEC-PRE-ACCURACY CRITERIA. TIVE PRE-ACCURACY TIVE REV PARED CHECK CHECK PAGE(S) PARED CHECK CHECK PAGE (S) fh,/ [f/f W 6-4.1 0 6-4.2 6-4.3 6-4.4 6-4.5 6-4.6 6-4.7 6-4.8 y N I f 3 f/)y![ 'TtN 6-4.9 0 o 'N QEP-001.4-00 6-vi nutggh

REVISION CONTROL SHEET O TITLE : Quad Cities Nuclear Power Station REPORT NUMBER: COM-02-039-6 Unit 1, Plant Unique Analysis Revision 0 Report, Volume 6 P. Pandey/ Consultant I INITIALS N. Jafarey/ Consultant I N 3~ INITIALS S. R. Farahani, P.E./ Associate Engineer S6 I INITIALS N. A. McClean, P.E./ Engineering Manager INITIALS INITIALS s INITIALS INITIALS EFFEC-EFFEC-PRE-ACCURACY CRITERIA TIVE REV PRE-ACCURACY CRITERIA TIVE REV PARED CHECK CHECK PAGE(S) PARED CHECK CHECK PAGE(S) 6-5.1 0 through SRF 88 d #-- 6-5.8 u i C% ( CEP-001.4-00 6-vii nutggh

REVISION CONTROL SHEET Quad Cities Nuclear Power Station COM-02-039-6 TITLE : Unit 1, Plant Unique Analysis REPORT NUMBER: Revision 0 Report, Volume 6 H. L. Gustin / Engineer INITIALS L. C. Hsu/ Supervising Engineer kN INITIALS Y. S. Wu/ Consultant I INITIALS A. Y. Kuo/ Consultant I INITIALS T. S. Hsu/ Associate Engineer TSM l INITIALS L. K. Chang / Specialist ,/' f c-INITIALS [~N D. G. Lee / Consultant I pg { INITIALS A. K. Rao/ Consultant II AK k INITIALS E E PRE-ACCURACY CRITERIA PRE-ACCURACY CRITERIA E REV E EV A ECK PARED CHECK CHECK PAGE(S) PAGE(S) 6-6.1 0 J/A Y5W M 6-6.19 0 NM AAE h through through 6-6.22 6-6.3 y y 6-6.23 p(gy (., Zrlc 6-6.4 through through 6-6.8 2}c 6-6.26 Qv 6-6.9 73# through 6-6.13 74 6-6.14 g tnrough 6-6.18 I M \\,nk i o p ,_ m. _ x V 6-viii nutp_qb

REVISION CONTROL SHEET Um TITLE: Quad Cities Nuclear Power Station REPORT NUMBER: COM-02-039-6 Unit 1, Plant Unique Analysis Revision 0 Report, Volume 6 P. Pandey/ Consultant I INITIALS N. Jafarey/ Consultant I NI INITIALS bR P S. R. Farahani,P.E./ Associate Engineer INITIALS N. A. McClean, P.E./Encineering Manager INITIALS T INITIALS J EFFEC-EFFEC-ACC M CY CRIE RIA PRE-ACCURACY CRITERIA TIVE REV TIVE REV PARED CHECK CHECK PACE (S) PARED CHECK CHECK PAGE(S) 6-7.1 0 5 R.F l'W

3. ~his.

6-7.2 } SRF PIO ?). 7HS. O QEP-001.4-;; l 6-1x nutggb

ABSTRACT The primary containments for the Quad Cities Nuclear Power Station Units 1 and 2 were designed, erected, pressure-tested, and N-stamped in accordance with the ASME Boiler and Pressure vessel Code, Section III, 1965 Edition with addenda up to and including Winter 1965 for the Commonwealth Edison Company (CECO) by the Chicago Bridge and Iron Company. Since

then, new requirements have been established.

These requirements affect the design and operation of the primary containment system and are defined in the Nuclear Regulatory Commission's (NRC) Safety Evaluation

Report, NUREG-0661.

This report provides an assessment of containment design loads postulated to occur during a loss-of-coolant accident or a safety relief valve discharge event. In addition, it provides an assessment of the effects that the postulated events have on containment systems operation. This plant unique analysis report (PUAR) documents the efforts undertaken to address and resolve each of the applicable s NUREG-0661 requirements. It demonstrates that the design of the ~primary containment system is adequate and that original design safety margins have been restored, in accordance with NUREG-0661 acceptance criteria. The Quad Cities 1 and 2 PUAR is composed of the following seven volumes: Volume 1 - GENERAL CRITERIA AND LOADS METHODCLOGY o o Volume 2 - SUPPRESSION CHAMBER ANALYSIS o Volume 3 - VENT SYSTEM ANALYSIS o Volume 4 - INTERNAL STRUCTURES ANALYSIS o Volume 5 - SAFETY RELIEF VALVE DISCHARGE LINE PIPING ANALYSIS Volume 6 - TORUS ATTACHED PIPING AND SUPPRESSION o CHAMBER PENETRATION ANALYSES (QUAD j CITIES UNIT 1) A t i V COM-02-039-6 Revision 0 6-x

. ~ _. ~ _ - _ o Volume 7 - TORUS ATTACHED PIPING AND SUPPRESSION ( CHAMBER PENETRATION ANALYSES (QUAD CITIES UNIT 2) This volume documents the evaluation of the torus attached piping and suppression chamber penetrations. Volume 1 through 4 and 6 and 7 have been prepared by NUTECH Engineers, Incorporated i (NUTECH), acting as an agent to the Commonwealth Edison Company. Volume 5 has been prepared by Sargent and Lundy (also acting as an agent to the Commonwealth Edison Company), who performed the safety relief valve discharge lines (SRVDL) piping analysis. Volume 5 describes the methods of analysis and procedures used in the SRVDL piping analysis. i i t O a I - N COM-0 2-03 9-6 Revision 0 6-xi

a ,,y- . m erg l x (No'<TH) q s N( % z i Figure 6-2.1-1 TAP SYSTEM ISOMETRIC AND SUPPORT LOCATIONS - RCIC TURBINE EXHAUST LINE (X-212) i NM COM-02-039-6 Revision 0 6-2.5 nutggb

6-2.1.1 Torus External Piping The torus external piping initiates at the ECCS suction header or at the penetration nozzles which cre connected to the torus shell through insert plates, and terminates at anchor supports or equipment within the reactor auxiliary building. From the torus, the lines typically extend up to the building slab at an elevation of 595'-0". However, some lines extend up to slabs at elevations of 623'-0" and 647'-6". The external piping is supported by hangers, rigid restraints, guides, and snubbers attached to building slabs or walls, or to main structural steel in the building. Figures 6-2.1-2 and 6-2.1-3 illustrate typical pipe supports outside the

torus, other components on these lines are valves and standard pipe fittings.

Valve types are gate valves, swing check valves, and nozzle type relief valves. Smaller lines branching off the large bore TAP are l discussed in Section 6-3.0. Piping supports are described in Section 6-4.0. Equipment such as valves, pumps, and turbines are described in Section 6-5.0. The suppression chamber penetrations are described in Section 6-6.0. O COM-02-039-6 g{ Revision 0 6-2.6

O I l MAIN STEEL N rr s e s // s INTERMEDIATE STEEL FRAMING q TAP LINE i t 2__ ,"_C .+ ~ ~ PIPE STRUT CLAMP I Figure 6-2.1-2 TYPICAL TAP SYSTEM SUPPORT OUTSIDE TORUS ATTACHED TO MAIN STEEL n COM-02-039-6 Revision 0 6-2.7 nutpsb

f 0 h %?@ ANCHOR BOLT (TYP) N >--+ 's 's INTERMEDIATE ls STEEL FRAMING $N >-I+ \\'s >-+ xx - - - - - _,4 _'_________1_. >--+ 3 SNUBBER ..J 9EEP !d $E-( 1 ) 0 0 -1 TAP LINE + e-m -w PIPE CLAMP Figure 6-2.1-3 TYPICAL TAP SYSTEM SUPPORT OUTSIDE TORUS ATTACHED TO CONCRETE WALL OR SLAB COM-02-039-6 Revision 0 6-2.8 nutgch

. = = - - T 6-2.1.2 Torus Internal Piping v Piping internal to the torus may be categorized into three basic configurations: a) Short penetration nozzles projecting inside the torus. Typical examples of this type of con-figuration are the vacuum

relief, pressure suppression and the emergency core cooling system.

The ECCS nozzles have a strainer connected to I their inner nozzle flange. Figure 6-2.1-4 shows a l typical penetration and

strainer, which is reinforced for Mark I loads.

l b) A short segment of piping inside the torus. In j some cases, these short segments are supported by plate strut assemblies attached to the torus shell or to the ring girders (Figure 6-2.1-5). c) A long length of pipe running through more than a single torus bay and-supported at the ring girders (Figure 6-2.1-6). l Supports for the torus internal piping are discussed in Section 6-4.0 l COM-02-039-6 Revision 0 6-2.9 ,.-_..m ,.c.r ......~ym ,-.,.v.. -e.-..-y.,,--wr-...--- .-y--y ww. rw-- -w v- - v---*

l i Loads and load combinations which are applied to the large bore TAP described above are presented in the following sections. l l O P i l l l l COM-02-039-6 Revision 0 6-2.10 nutE_h.

Om SM SUCTION-STRAINER N 4 N

  1. { ECCS SUCTION
  • s HEADER

/ l l I s \\ / s \\~~.. ' / l / \\ ( NOZZLE l Figure 6-2.1-4 TYPICAL SUCTION STRAINER PENETRATION COM-02-039-6 Revision 0 6-2.11 nutggb

O { AND RING GIRDER RHR DISCHARGE LINE w / H a PIPE STRUT l g g ASSEMBLY PLATE STRUT d ASSEMBLY i i I e /l RING GIRDER d REINFORCEMENT BEAM 1 l_ 4" (REF) { MITER SUPPRESSION JOINT CHAMBER SHELL Figure 6-2.1-5 TYPICAL TAP SYSTEM SUPPORT INSIDE TORUS, COM-02-039-6 Revision 0 6-2.12 nutp_qh

O ( TORUS' RING GIRDER \\ ^ ll 8 7/16* \\ REINFORCEMENT T ~ i~ PLATE (REF) HEADER E ~ l l SPRAY 1 1 U-STRAP 4" DIA O4 N PIPE 12'-6" (REr> / g M N / U Figure 6-2.1-6 TYPICAL TAP SYSTEM SUPPORT INSIDE TORUS ATTACHED TO RING GIRDER %d COM-02-039-6 Revision 0 6-2.13 I

6-2.2 Loads and Load Combinations The loads for which the Quad Cities Unit 1 TAP is designed are defined in NUREG-0661 on a generic basis for all Mark I plants. The methodology used to develop plant unique TAP loads for each load defined in NUREG-0661 is discussed in Volume 1. The results of applying the methodology to develop specific values for each of the controlling loads which act on the piping are discussed and presented in Section 6-2.2.1. Using the event combinations and event sequencing defined in NUREG-0661 and discussed in Volume 1, the governing load combinations which affect the torus attached piping are formulated. The load combinations are discussed and presented in Section 6-2.2.2. i O COM-02-039-6 Revision 0 6-2.14 nut Lh

i l 6-2.2.1 Loads The loads acting on the TAP are categorized as follows: 1. Dead Weight Loads 2. Seismic Loads i 3. Pressure and Temperature Loads 4. Operating Loads 5. Static Torus Displacement Loads 6. Safety Relief Valve Discharge Loads 7. Vent Clearing Loads 8. Pool Swell Loads 9. Condensation Oscillation Loads 10. Chugging Loads 11. Torus Motion Loads Loads in Categories 1 through 4 are considered in the piping design as documented in the SAR (Reference 4). The SAR loads considered in the piping evaluations are those normal loads which are combined directly with Mark I loadings (LOCA and SRV discharge) as well as SAR loads considered for evaluation of system design and test conditions. Loads-in Category 5 are displacements resulting from torus internal pressure or water dead . weight during both normal and accident conditions. Loads in Category 6 result from SRV discharge events. 1O COM-02-039-6 Revision 0 6-2.15 l

I Loads in Categories 7 through 10 result from postulated LOCA events. Loads in Category 11 consist of torus inertial and displacement responses due to hydrodynamic loads acting on the torus. Not all of the loads defined in NUREG-0661 and the SAR need be examined, since some are enveloped by others or have a negligible effect on the torus attached piping. Only those loads which cause the maximum piping response and lead to controlling stresses are examined and discussed. The loads are referred to as governing loads in the following sections. The magnitudes and characteristics of the governing loads in each category, obtained using the methodology discussed in Volume 1, are identified and presented in the following paragraphs. The corresponding section of Volume 1 where the loads are discussed is provided in Table 6-2.2-1. The loading information presented in this section is the same as that presented in volume 1, with additional specific information relevant to the evaluation of the TAP systems. 1. Dead Weight (DW) Loads These loads are defined as the uniformly dis-tributed weight of the pipe and insulation, and COM-02-039-6 Revision 0 6-2.16 nut

the concentrated weight of piping

supports, hardware attached to
piping, valves, and flanges.

Also included is f;he weight of the contents of the torus attached piping. 2. Seismic Loads a. OBE Inertia (OBEg) Loads: These loads are defined as the horizontal and vertical accel-erations acting on the TAP during an operat-1 ing basis earthquake (OBE). The loading is taken from the design basis for the piping as documented in the safety analysis report. Horizontal building response spectra at two different elevations which represent piping attachment points are utilized for the N-S and E-W direction OBE inputs. 7 b. OBE Displacement (OBED) Loads: These loads are defined as the maximum horizontal and vertical relative seismic displacements at 4 i the piping attachment points during an operating basis earthquake. The loading is taken from the design basis for the piping, as documented in the safety analysis report. O COM-02-039-6 Revision 0 6-2.17

Table 6-2.2-2 provides the OBE relative displacements in the N-S, E-W, and vertical directions. c. SSE Inertia (SSEy) Loads: These loads are defined as the horizontal and vertical accelerations acting on the piping during a safe shutdown earthquake (SSE). The loading is taken from the design basis for the piping, as documented in the safety analysis report. The response spectra curves for the inputs N-S, E-W, and vertical directions SSE7 are twice the corresponding OBEr inputs. d. SSE Displacement (SSED) Loads: These loads are defined as the maximum horizontal and vertical relative seismic displacements at the piping attachment points during a safe shutdown earthquake. The SSE are twice the D corresponding OBE Table 6-2.2-2 provides D. the SSE relative displacements in the N-S, E-W, and vertical directions. O COM-02-039-6 Revision 0 6-2.18 outp_qh

(O 3. Pressure and Temperature Loads a. Pressure (P, P) Loads: These loads are o defined as the maximum operating internal pressure (P ) and design condition pressure o (P), in the torus attached piping. Table 6-2.2-3 lists values of P and P used in the o analysis. b. Temperature (TE, TEy) Loads: These loads are defined as the thermal expansion (TE) of the piping associated with temperature changes occurring during normal operating conditions, and the thermal expansion (TEy) of the piping associated with temperature changes occurring during accident conditions. Table 6-2.2-3 lists pipe temperatures for TE and TEy used in the analysis. Effects of thermal anchor movements at the torus penetrations, torus

supports, and external anchors (e.g.,

pumps, turbines, and drywell penetrations) are also included in the analysis. The piping thermal anchor movement loadings are categorized and designated as follows: w/ COM-02-039-6 Revision 0 6-2.19

Piping thermal anchor movement 1. THAM during normal operating conditions (NOC), and 2. THAM 1-Piping thermal anchor movement during accident conditions. 4. Operating (OL) Loads These loads are defined as line operating thrust loads due to discharge of piping contents inside the torus. The loads are applicable to the HPCI turbine exhaust, the RCIC turbine exhaust, and the RHR test lines. 5. Static Torus Displacement Loads These loads are defined as the torus displacement loads due to dead weight of the torus, weight of water in the

torus, and normal operating and accident condition pressures.

a. TD These are the torus displacements due to normal operating pressure, dead weight of the torus, and the weight of water in the torus. COM-02-039-6 Revision 0 6-2.20 nutgg])

x These are the torus displacements b. TD1-due to torus internal pressure during SBA conditions, dead weight of the torus, and the weight of water in the torus. t These are the torus displacements c. TD2-due to torus internal pressure during IBA conditions, dead weight of the torus, and the weight of water in the torus. d. TD3-These are the torus displacements due to torus internal pressure during DBA conditions,. dead weight of the torus, and the weight of water in the torus. l 6. Safety Relief Valve Discharge (QAB) Loads These loads are defined as the transient pressures which act on the submerged portion of the TAP and supports in the torus during a SRV discharge. The SRV discharge loads consist of the following: I ' p O COM-02-039 Revision 0 6-2.21 l

a. Water Jet Impingement Loads: During the water clearing phase of a SRV discharge

event, the submerged TAP and supports are

/ subjected to transient drag pressure loads. The procedure used to develop the transient forces and spatial distribution of these loads is discussed in Volume 1. b. Air Bubble Drag Loads: During the air clearing phase of a SRV discharge

event, transient drag pressure loads are postulated to act on the submerged TAP and supports.

The procedure used to develop the transient forces and spatial distribution of these loads is discussed in Volume 1. Loads are developed for several possible patterns of air bubbles for both single and multiple T-quencher discharge cases. The results are evaluated to determine the controlling loads. 7. Vent Clearing (VCL And VCLO) Loads These loads are defined as the transient pressure i loads acting on the submerged portion of TAP and O COM-02-039-6 Revision 0 6-2.22 nutggb

supports during the water and air clearing phase of a DBA event. They are defined for two condi-tions: those with a differential pressure ( P) between the drywell and the wetwell (VCL) and those without the differential pressure (VCLO). a. LOCA Water Jet Impingement Loads: During the water clearing phase of a DBA event, the submerged portion of the TAP and supports are subjected to transient impact and drag pressure loads. The procedure used to develop these transient drag forces is discussed in Volume 1. 'J b. LOCA Air Bubble Drag Loads: During the air clearing phase of a DBA event, the submerged 4 portions of the TAP and supports 'are sub-jected to transient drag pressure loads. The j procedure used to develop these transient drag forces is discussed in Volume 1. 8. Pool Swell (PS and PSO) Loads These loads are defined as the transient pressure loads which act on the torus internal piping and supports. They are defined for two cases: those h\\- G COM-02-039-6 Revision 0 6-2.23 L nutggb g w-g 4 c-- ,f -m-sm -r-9yyw y e- - - - w upw ?? +

with a differential pressure between the drywell and wetwell (PS) and those without the differ-ential pressure (PSO). a. Impact and Drag Loads: During the initial portion of a DBA event, the TAP and supports within the torus are subjected to transient pressures. The procedure used to develop these pressure transients is discussed in Volume 1. b. Froth Impingement Loads: During the LOCA pool swell event, the TAP and supports within the torus are subjected to transient pres-sures. The procedure used to develop these pressure transients is discussed in Volume 1. c. Pool Fallback Loads: During the later phase of pool swell, the TAP and supports within the torus are subjected to transient pressures. The procedure used to develop these pressure transients is discussed in Volume 1. I COM-02-039-6 Revision 0 6-2.24 nutggh

9. Condensation oscillation (CO) Loads During the CO phase of a DBA event, the submerged portion of the TAP and supports within the torus are subjected to harmonic velocity and acceler'a-tion drag pressures. The procedure used to develop the harmonic drag loads is discussed in Volume 1. Included are acceleration drag loads due to torus fluid-structure interaction (FSI). 10. Chugging Loads a. Pre-Chug (PCHUG) Loads: These loads are / defined as single harmonic velocity and ( acceleration drag loads, including accelera-tion drag loads due to torus FSI effects, acting on the submerged portion of the TAP 4 and supports during the pre-chug phase of a

SBA, IBA, or D3A event.

The procedure used to develop the pre-chug loads on these com-ponents is discussed in Volume 1. b. Post-Chug (CHUG) Loads: Tnese-loads are defined as harmonic velocity and acceleration drag loads, including acceleration drag loads due to torus FSI

effects, acting on the COM-02-039-6 Revision 0-6-2.25 nutggb

submerged portion of TAP and supports during the post-chug phase of a SBA, IBA, or DBA event. The procedure used to develop the post-chug loads on these components is discussed in Volume 1. 11. Torus Motion Loads These loads are defined as the inertia and dis-placement effects at the TAP attachment points on the suppression chamber due to loads acting on the suppression chamber shell. a. SRV Torus Motion Loads: These are the inertia effects 1. QABy of torus motions due to SRV T-quencher discharge loads. 2. QAB9 These are the displacement effects of torus motions due l l to SRV T-quencher discharge I I loads. l l O COM-02-039-6 Revision 0 ' C-2.26 nutggh

b. Pool Swell Torus Motion Loads: and PSOy - These are the inertia 1. PSI effects of torus motions due to pool swell loads for operat-ing AP and zero AP, respectively. These are the displace-2. PSD and PSOD ment effects of torus motions due to pool swell loads for operat-ing AP and zero AP, respectively. c. Condensation Oscillation Torus Motion Loads: These - are the inertia effects 1. CO y of torus motions due to CO loads. These are the displacement 2. COD effects of torus motions due to CO loads. O COM-02-039-6.. Revision 0 6-2.27

d. Pre-Chug Torus Motion Loads: 1. PCHUGy-These are the inertia effects of torus motions due to pre-chug loads. These are the displacement 2. PCHUG D effects of torus motions due to pre-chug loads. e. Post-Chug Torus Motion Loads: 1. CHUGI These are the inertia effects of torus motions due to post-chug loads. 2. CHUG These are the displacement D effects of torus motions due to post-chug loads. I 1 COM-02-039-6 Revision 0 6-2.28 nutggh

I Table 6 -2. 2-1 TORUS ATTACHED PIPING LOADING IDENTIFICATION CROSS-REFERENCE LOAD DESIGNATION VOLUME LOAD LOAD REFERENCE NUMBER CATEGORY CASE NUMBER DEAD WEIGHT 1 1-3.1 SEISMIC 2 1-3.1 1 PRESSURE AND 3 1-3.1, 1-4.1.1 TEMPERATURE OPERATING 4 1-3.1 STATIC TORUS 5 1-3.1, 1-4.1.1 DISPLACEMENT ) SRV DISCHARGE 6 1-4.2.2, 1-4.2.4 VENT CLEARING 7 1-4.1.S, 1-4.1.6 POOL SWELL 8 1-4.1.4.2, 1-4.1.4.3, 1-4.1.4.4 CONDENSATION 9 l-4.1.7.3 OSCILLATION CHUGGING 10 1-4.1.8.3 TORUS MOTION 11 1-4.1, 1-4.2 l i COM-02-039-7 Revision 0 6-2.29 O

Table 6-2,2-2 MAXIMUM SEISMIC RELATIVE ANCHOR DISPLACEMENTS OBE DISPLACEMENT (in phase) RELATIVE'TO BASE LOCATION ELEVATION N-S E-W (inches) (inches) 552'-0" FIXED FIXED 571'-6" 0.02 0.02 595'-0" 0.02 0.02 623'-0" 0.05 0.05 REACTOR 647'-6" 0.07 0.07 BUILDING 666'-6" 0.07 0.10 j 690'-6" 0.07 0.10 711'-9" 0.14 0.89 736'-9" 0.41 0.98 615'-6" 0.02 0.02 TURBINE 626'-6" 0.05 0.05 BUILDING 639'-0" 0.05 0.07 i i I l COM-02-039-6 Revision 0 6-2.30 nutggh

f% /q ) D) V j i 4 v 4 gQ Table 6-2.2-3 < :r $o LARGE BORE PIPING SYSTEM DESIGN DATA E'? Do o NAxmDM MEWING A NORMAL DESIGN CONDITIONS OPERATING SYSTEM CONTENTS TEMPERATURE PRESSURE TEMPERATURE PRESSURE TEMPERATURE (o ) p (psig) (P ) (DF) (psig) (P) (OF) o PRESSURE SUPPRESSION 90 35 165 55 285 AIR i ECCS SUCTION HEADER 90 35 165 55 285 WATER VACUUM RELIEF 90 35 165 55 285 AIR RHR TEST LINE AND SPRAY HEADER DISCHARGE 90 180 280 415 400 WATER FROM PUMP 1A/lB AND IC/1D m b RCIC TURBINE EXHAUST 280 35 280 150 360 8^$g"ATED gg HPCI TURBINE EXHAUST 240 50 295 150 300 SA$AdED HPCI POT DRAIN 145 60 145 60 285 WATER RCIC POT DRAIN 160 35 160 150 200 WATER RHR PUMP 1A/lB AND 90 35 165 55 285 WATER IC/lD SUCTION CORE SPRAY 1A/lB 90 35 165 55 285 WATER PUMP SUCTION I HPCI PUMP SUCTION 90 35 165 55 285 WATER RCIC PUMP SUCTION 90 35 165 55 285 WATER i

6-2.2.2 Load Combinations The loads for which the TAP systems are evaluated are presented in Section 6-2.2.1. The NUREG-0661 criteria for grouping the loads into load combinations are discussed in Volume 1. Table 6-2.2-4 shows that the load combinations speci-fied in NUREG-0661 for each cvent can be expanded into many more load combinations than those shown.

However, not all load combinations for each event need be examined, sirce many have the same allowable stresses and are enveloped by others which contain the same or additional loads.

Many of the load combinations listed in Table 6-2.2-4 are actually pairs of load combinations with all of the same loads except for seismic loads. The first load combination in the pair contains OBE

loads, while the second contains SSE loads.

The governing load combinations for torus attached piping are presented in Table 6-2.2-5. Table 6-2.2-6 presents the basis for establishing the governing loading combinations. l COM-02-039-6 Revision 0 6-2.32 nutggh

Stress allowables corres,ponding to the following v Service Lovels are used for evaluation of the torus attached piping: A-Design conditions, B-NOC including SRV diccharge, C-NOC including SRV discharge, plus seismic loads or SBA conditions including SRV discharge, and D-SBA, IBA, and DBA conditions including SRV dis-charge plus seismic loads. Also included in the list of governing load combina-tions are four combinations which do not result from , [ the 27 event combinations listed in Table 6-2.2-4. These are: Load Combination A-1, which relates to the design pressure plus dead weight condition; Load Combinations A-2 and B-1, which include the combination of normal and seismic loads; and Load Combination T-1, which relates to the hydrostatic test condition. Evaluation of Load Combination T-1 is a requirement of j the ASME Code (Reference 6). Load Combinations A-1, A-2, and B-1 are consistent with the requireme'nts as specified in the SAR (Reference 4). The normal SAR loads included in the loading l combinations are assumed to occur simultaneously with / \\\\ COM-02-039-6 ' Revision.0 6-2.33 nutggh

the NUREG-0661 loads for the LOCA event sequences defined in the LDR (Reference 2). The appropriate ASME Code equations for the torus attached piping are also provided in the governing load combination table. Each of the listed governing load combinations for the torus attached piping as provided in Table 6-2.2-5 has been considered in the analysis methods described in Section 6-2.4. O i COM-02-039-6 Revision 0 6-2.34 nutggh

t El e =l:: j=l-l-l-ll l- =Ela la5 I - i .l: l-l-l-l-l 1 - l : El-Ias i' g

-l-l ~ l-l-l-l l

=El f ai l = i 2 - : -l-1 i-l-i-l 1 El-Ias l' El - aE l - ! is

-l l-l-l-l l - :

i

-ll-l-l-i-1 El -

as l ' -ll1t-ll El- =El-e a g .gl. og l. .l.l }.),l l. e . :.-i-ll-l-l-l =El- =E l - g t . : -l-l l-l-i-1 =El- =5 i ' m ejle of l e b d5 "l l-l-lm l ~ -l

  • Ele as l e Z

25

=l l- =

mElej og l af 4 EE s e =l=l=l-l- = g j' i -l l - i1-El Eu as Ias w g I El E as Ia5 a -l-l-g g ja l ajl a{ af l a3 aslml-e a. m se 7 !! se - l-El-E os l =E O hk l

  • Elaf of 1: a3

- l' -

7 g k 5 ef'iaf a6 1.of l m e a a a m. = = h ej ej af af e. m a a o m 4 -+ as og ag l- = es w 2 gg a c. is = 4 O. m a-g e O e e a al g m e.- a.- e-_ a-_ l =l -l aC O pg z e gi m2 a 93 = m; = i .i .E 5 as .E g e ..i .El as .i. u .i. .i 5 5 g i .,.-i s. ...i

3 s 1 : - :

2 :: l i l i i n i i i = o s i i g l* 1 i c l g E E E E 8 8 2 E E E E a $ g s I i!! II:; g COM-02-039-6 Revision 0 6-2.35 l nutggb I

gQ NOTES TO TABLE 6-2.2-4

if OO (1)

REFERENCE 1 STATES "WilERE A DRYWELL-TO-WETWELL PRESSURE DIFFERENTIAL IS NORMALLY o UTILIZED AS A LOAD MITIGATOR, AN ADDITIONAL EVAI.UATION SilALL HE PERFORMED WITilOUT UO SRV LOADINGS BUT ASSUMING THE LOSS OF Tile PRESSURE DIFFERENTI AL." SERVICE LEVEL C)

  • D LIMITS S!!ALL APPLY FOR ALL STRUCTURAL ELEMENTS OF TIIE PIPING SYSTEM FOR TIIIS EVALUATION.

Tile ANALYSIS NEED ONLY BE ACCOMPLISilED TO Tile EXTENT TilAT INTEGRITY OF TIIE FIRST PRESSURE BOUNDARY ISOLATION VALVE IS DEMONSTRATED." (2) REFERENCE 1 STATES " NORMAL LOADS (N) CONSIST OF DEAD LOADS (D). " (3) REFERENCE 1 STATES "AS AN ALTERNATIVE, TIIE 1.2 Sgg LIMIT IN EQUATION 9 OF NC-3652.2 MAY BE REPLACED BY 1.8 Sg, PROVIDED TIIAT ALL OTIIER LIMITS ARE SATISPIED. FATIGUE REQUIREMENTS ARE APPLICABLE TO ALL COLUMNS, WITil Tile EXCEPTION OF 16, 18, 19, 22, 24 AND 25." -(4) REFERENCE 1 STATES " FOOTNOTE 3 APPLIES EXCEPT TilAT INSTEAD OF USING 1.8 Sgg IN EQUATION 9 OF NC-3652.2, 2.4 SH IS USED." (5) REFERENCE 1 STATES " EQUATION 10 OF NC WILL DE SATISFIED, EXCEPT TilAT m FATIGUE REQUIREMENTS ARE NOT APPLICABLE TO COLUMNS 16, 16, 19, 22, 24 AND 25 SINCE i POOL SWELL LOADINGS OCCUR ONLY ONCE. IN ADDITION, IF Ol'ERABILITY OF AN ACTIVE F COMPONENT IS REQUIRED TO ENSURE CONTAINMENT INTEGRITY, OPERABILITY OF TilAT COMPONENT ~ w MUST BE DEMONSTRATED." m 1 e C e o e

7 p

\\ ) i G(. Table 6-2.2-5 .g g <x [*$ GOVERNING LOAD COMBINATIONS - TORUS ATTACilED PIPING !r ? "S oe NUREG-0661 ASME 1 LOAD (1*5*6) COMBINATION I4AD COMBINATIONS CODE NUMBER EQUATION e A-1 P.+ DW + OL 8 A-2 TE + TIIAM + TD + OBE 0 D 10 A-3 TE + TIIAM + TD + QADD + SSED or TD r TD3 + PCilUGD + QADD + SSED A-4 TEy + TIIAMy + TDy 2 or TD or TD3* UUD + QABD + SSED A-5 TEy + THAMy + TDy 2 II A-6 TEy + TIIAMy + TD3 + PSOD 0 II 7 A-7 TEy + T!!AMy + TD3 + PSD+0 D* D 10 I4I 10 A-B TEy + TIIAMy + TD3 + COD + OBED 4 B-1 P + DW + OBE + OL 9 g 7 D-2 P + DW + CAB + QAB7 + OL 9 g c-1 P + DW + QAB + QAB7 + SSE7 + OL 9 g i C-2 P +. DW + PCIIUG + PCIIUG + QAB + QAB7 + OL 9 7 C-3 P + DW + CIIUG + CIIUG + QAB + QAB7 + OL 9 g 7 II D-1 P + DW + PCilUG + PCIIUGy + QAB + QAB7 + SSE7 + OL 9 g D-2(8) P + DW + CllUG + CIIUG + QAB + QAB7 + SSE7 + OL 9 g 7 II i D-3 P + DW + PSO + PSO + VCM + OL 9 g 7 ) D-4 P + DW + PS + PSy + VCL + QAB + QAB7 + SSE7 + OL 9 g D-5 P + DW + CO + CO 5 OBE + OL 9 g 7 7 T-1 1.25P + DW 8 3 C

yQ NOTES TO TABLE 6 -2. 2-5 E? [o (1) SEE SECTION 6-2.2.1 FOR DEFINITION OF INDIVIDUAL LOADS. Oo (2) EQUATIONS ARE DEFINED IN SUBSECTION NC-3650 OF TIIE ASME CODE (REFERENCE 6). oy (3) AS AN ALTERNATE, MEET EQUATION 11 OF TIIE ASME CODE (REFERENCE 6). (4) FOR THE DBA CONDITION, SRV DISCIIARGE LOADS WEED NOT BE COMBINED WITH CO AND CIIUGGING LOADS. (5) SEE SECTION 6-2.2.3 FOR COMBINATION OF DYNAMIC LOADS. (6) ONLY GOVERNING LOAD COMBINATIONS FROM TABLE 6-2.2-4 ARE CONSIDERED llERE. (7) ONLY PIPING OUT TO THE FIRST ISOLATION VALVE NEEDS TO BE EVALUATED. (8) TIIE LARGER OF LOCA AND SSE COMBINED BY TIIE SRSS METIIOD OR LOCA AND OBE COMBINED BY THE ABSOLUTE SUM METIIOD IS USED. (9) liYDROSTATIC TEST CONDITION. DW FOR ALL LINES SHALL BE WITil LINES FULL 0 OF WATER AT 70 F. k b.

\\ Table 6-2.2-6 BASIS FOR GOVERNING LOAD COMBINATIONS - TORUS ATTACHED PIPING EVENT EVENT GOVERNING COMBINATION COMBINATION LCAD DISCUSSION GOVERNING NUMBER (1) COMBINATIONS (2) ggggg SECONDARY STRESS MOUNDED (3b) i B-2* BY EVENT COMBINATION NUMBER 3. SECONDARY STRESS BOUNDED BY 2 C-1 EVENT COMBINATION NUMBER 3. 3 C-1. A-3 N/A N/A IBA BOUNDED BY EVENT COMBINA-4,5 N/A TION NUMBER 15 AND S8A BOQUDZD (3b) BY E1FENT CCMBINATION NUMBER 11. 6,8,12 N/A (3b) NUMBER 14. BOUNDED BY EVENT COMBINATION 7,9, 13 N/A (3b) NUMBER 15. IBA BOUNDED BY EVENT COMBINA-10 N/A TION NUMBER 15 AND SBA SOUNDED (3b) BY EVENT COMBINATION NUMBER 11. C-2, C-3 FOR 58A ONLY. IBA BOUNDED BY \\ 11 I3DI A-4, A-5 EVENT COMBINATION NUMdER 15. 0-1. D-2 15 N/A N/A A-4, A-5 14 D-1* 0-2 SECONDARY STRESS SOUNDED BY (3,3 EVENT COMBINATION NUMBER 15 BOUNDED BY EVENT COMBINATION 16,18,22 N/A (3b) NUMBER 24. OMBINAUCN 19 N/A (3b) NUMBER 25. BO M ED BY EVENT COMBINATION 17,20,23 N/A (3b) NUMBER 26. BOUNDED BY EVENT COMBINATION 21 N/A (3b) NUMBER 27. SECONDARY STRESS SOUNDED BY 24 D-3, D-4 ( "' EVENT COMBINATION NUMBER 25. D-3, A-6 N/A N/A 25 0-4, A-7 FOR CO ONLY, DBA CHUGGING BOUNDED BY EVENT CCMBINATION 26 D-5, A-8 NUMBER 14. SECONDARY STRESS (3b) BOUNDED BY EVENT COMBINATION NUMBER 27. DBA CHUGGING BOUNDED BY 27 A-4* A-5 EVENT COMBINATION NUMBER 15. EVALUATE FOR SECONDARY I3DI STRESS ONLY. l_. LM COM-02-039-6 Revision 0 6-2.39 nutggb

Eo NOTES TO TABLE 6-2.2-6 $? to o o" (1) EVENT COMBINATION NilMt!ERS ItEFER TO Tile NUMBERS USED IN TABLE 6-2.2-4. "S oy (2) GOVERNING LOAD COMBINATIONS ARE LISTED IN TABLE 6-2,2-5. (3)- EVENT COMBINATION GOVERNING BASIS: a. Tile GOVERNING EVENT COMBINATION CONTAINS SSE LOADS WilICH BOUND OBE IDADS. b. TiiE GOVERNING EVENT COMBINATION CONTAINS MORE LOADS WHILE Tile ALLOWABLE LIMITS ARE Tile SAME. s 4 o e e

6-2.2.3 Combination of Dynamic Loads The methods used in the analyses for combining dynamic loads are based on NUREG-0484, " Methodology for Combining Dynamic Responses" (Reference 8). As described in NUREG-0484, when the time-phase relation-ship,between the responses caused by two or more sources of dynamic loading is undefined or random, the peak responses from the individual loads are combined by absolute sum (except for combined SSE and LOCA loads). The peak responses which result from SSE and LOCA loads are combined using the SRSS technique. As an alternate, when the absolute sum method of combining dynamic loads produces excessively conservative results, the dynamic loads are combined using the SRSS method, as permitted by Reference 9. w COM-02-039-6 Revision 0 6-2.41 nutggh

6-2.3 Acceptance Criteria The acceptance criteria defined in NUREG-0661 upon which the Quad Cities Unit 1 TAP analysis is based are discussed in Volume 1. In general, the acceptance criteria follow the rules contained in the ASME Code, Section III, Division 1 up to and including the 1977 Summer Addenda for Class 2 piping (Reference 6). The corresponding service level limits and allowable stresses are also consistent with the requirements of the ASME Code and NUREG-0661. The torus attached piping is analyzed in accordance with the requirements for Class 2 piping systems contained in Subsection NC of the Code. Table 6-2.3-1 lists the applicable ASME Code equations and stress limits for each of the governing piping load combinations. l l COM-02-039-6 Revision 0 6-2.42 nutp_qh

n Table 6-2.3-1 l APPLICABLE ASME CODE EQUATIONS AND ALLOWABLE STRESSES FOR TORUS ATTACHED PIPING ASME CODE SERVICE OEMEG LOAD STRESS STRESS Q A ION MM COMBINATION TYPE LIMIT (ksi) NUMBER (3) (4) NUMBER (1) PRIMARY 8 A 1.0 S 15.0/18.6 A-1, T-1 h PRIMARY 9 B 1.2 S .0/22.32 B-1, B-2 h PRIMARY 9 B 1.8 S 27.0/33.48 C-1 THROUGH C-3 h PRIMARY 9 B 2.4 S 36.0/44.64 D-1 THROUGH D-5 3 SECONDARY 10 B 1.0 S, 22.5/27.9 A-2 THROUGH A-8 PRIMARY AND 11 B S*a 37.5/46.5 (2) h b SECONDARY _\\ j (1) GOVERNING LOAD COMBINATION NUMBERS ARE LISTED IN TABLE 6-2.2-5. (2) SEE ASME CODE, SECTION III, SUBSECTION NC, PARAGRAPH NC-3652.3 (REFERENCE 6) FOR COMBINATION OF LOADS. (3) INCREASED ALLOWABLES AS DEFINED IN NUREG-0661 (REFERENCE 1) HAVE BEEN UTILIZED FOR PIPING SYSTEMS WHICH HAVE BEEN CLASSIFIED AS NON-ESSENTIAL. (4) CARBON STEEL / STAINLESS STEEL. N COM-02-039-6 Revision 0 6-2.43 nutggh

6-2.4 Methods of Analysis This section describes the methods of analysis used to evaluate the large bore piping systems attached to the torus both internally and externally, for the effects of the governing loads as describad in Section 6-2.2. As described in Section 6-2.1, selected small diameter torus internal piping systems have also been evaluated using the analytical methods described in this section. Table 6-2.4-1 summarizes the specific analytical techniques used in analyzing the piping systems for each loading. The mE.hodology used to develop the structural models of the TAP systems is presented in Section 6-2.4.1. The methodology used to obtain results for the governing load combinations and to evaluate the analysis results for comparison with the acceptance limits is discussed in Sections 6-2.4.2, 6-2.4.3, and 6-2.4.4. The approach used to address fatigue effects is presented in Section 6-2.4.5. A

standard, commercially available piping analysis computer code, PISTAR, is used in performing the piping system analyses.

The computer code is based on the well known SAP computer program, and has been verified COM-02-039-6 Revision 0 6-2.44 nutgch

.~ _ _ _.. [ l i using ASME benchmark problems. The PISTAR program l performs ~ static, modal extraction, response spectrum, [ and dynamic time-history analyses of piping systems. It also performs the ASME Code, Section III piping l l i evaluation. i j' t i i I i i i l l t I i b i l l' l l i t l' t t i i i i t COM-02-039-6 l Revision 0-6-2.45 nutggb = r-re.. .r -w,-..., .<.---.----....-.+=L,--.. . + o..-- --~,---.ww_

Table 6-2,4-1

SUMMARY

OF ANALYSIS METHODS FOR LARGE BORE TORUS ATTACHED PIPING U LOAD ANALYSIS METHOD N MB DN 1 STATIC OBE 2a RESPONSE SPECTRUM 7 OBE STATIC D SSE 2c ESPONSE SqECNM 7 SSE 2d STATIC D P, 3a (1) P 3a (1) f TE 3b STATIC TE 3b STATIC 1 THAM 3b STATIC l. THAM 3b STATIC y OL 4 STATIC TD Sa STATIC TD 5b STATIC y TD Sc STATIC 2 TD 5d STATIC 3 ( QAB 6a,b EQUIVALENT STATIC VCL, VCLO 7a,b EQUIVALENT STATIC PS; PSO Sa,b,c EQUIVALENT STATIC CO 9 DYNAMIC PCHUG 10a DYNAMIC CHUG 10b DYNAMIC l QAB lla COW MD D W M C/ N M 7 y QAB 118 STATIC D 2 PS PSO lib COWMD DWAMIC/NM 7, 7 y PSOD 2 CO, lle COUPLED DYNAMIC /MRSM( I y I4) CO lic STATIC 2 HUG lid COUPLED DYNAMIC /MRSM( ) 7 t PCHUC l1d STATIC (4) D 2 CHUG lle COWMD DWAMIC/MRSM 7 y I4) CHUG lle STATIC g 2 COM-02-039-6 Revision 0 6-2.46 nutggh

O O O gQ NOTES TO TABLE 6-2. 4-l &? %O (1) THE EFFECTS OF INTERNAL PRESSURE ARE EVALUATED UTILIZING THE TECHNIQUES g og DESCRIBED IN SUBPARAGRAPH NC-3650 OF Tile ASME CODE, SECTION III (REFERENCE 6). oU (2) THE COUPLED DYNAMIC ANALYSIS METHOD FOR TORUS MOTION LOADS AS DESCRIBED IN l SECTION 6-2.4.4 HAS BEEN UTILIZED FOR ALL PIPING SYSTEMS LISTED IN TABLE 6-1,1-1 8 EXCEPT LINES X-223A, X-223B, X-224A, X-224B, X-225, AND X-226. FOR THESE LINES, TIIE MULTIPLE RESPONSE SPECTRUM METiiOD (MRSM) IS USED. (3) A DETAILED DESCRIPTION OF Tile ANALYSIS METiiODS USED FOR THIS LOADING IS PRESENTED IN SECTION 6-2.4.3. j (4) DISPLACEMENT LOADS ARE APPLIED SEPARATELY WIIEN INERTIA LOADS ARE ANALYZED BY M RSM. FOR TIIE COUPLED DYNAMIC METIIOD, BOT!! Tile INERTIA AND DISPLACEMENT LOADS ARE INCLUDED IN TiiE ANALYSIS. l l 7 1 1 i e

6-2.4.1 Piping Analytical Modeling The structural models used in the analysis of the large bore TAP fall into the following two categories: piping models which represent systems with only torus external piping, and piping models which include both torus internal and torus external piping. Figure 5-2.4-1 shows a representative torus internal and external piping model. The piping systems are modeled as multi-degree of freedom (DOF), finite element systems -consisting of straight and curved beam elements using a lumped mass formulation. Sufficient detail is used to accurately represent the dynamic behavior of the piping systems for the applied loads. Flexibility and stress intensification factors based on the ASME Code, Section III, Class 2 piping requirements are also included in the model formulations. l Torus external piping supports included in the models consist of snubbers, struts, spring hangers, and their backup structures. Where

required, an element is included to model the offset connection between the supporting member and the centerline of the pipe.

COM-02-039-6 Revision 0 6-2.48 nutg,gh

Snubbers are modeled as active in seismic and other dynamic load cases, while struts and spring hangers are f active in all load cases. Spring hangers are modeled with appropriate preloads. The effects of the mass of supports and connecting hardware attached to the piping are included in the piping models when the effective support mass attached to the piping exceeds 5% of the mass of both adjacent pipe spans. Stiffness values at a piping support location are established considering the combined effects of the standard component hardware (e.g., snubber or strut) and its backup supporting structure. n a^ For piping models that have torus internal piping, the entire piping system including the internal supports connected to the torus, is included in the model. The hydrodynamic mass acting on submerged portions of the piping is also included in'the model, using the methods described in Volume 1. Boundary conditions for the piping models at the torus consist of the torus penetration and attachment points for the torus internal piping supports. The local i stiffness of the torus is included at these locations in the form of six DOF linear springs. These local 1 k COM-02-039-6. Revision 0 6-2.49 nutg_qh

stiffnesses are not included when performing the coupled torus motion analyses of the piping systems since they are inherently included in this methodology. Model boundary conditions at the torus external termination points consist of anchors at support or equipment (pump, turbine) locations. Large stiffness values are specified in the models at these locations. In some cases, piping models used to evaluate the effects of NUREG-0661 loads are truncated at locations where stress levels due to those loadings have attenuated to less than 10% of the appropriate ASME Code allowables. At these truncation points, the mass and stiffness of the excluded portions of the piping system are simulated. The mass and flexibility properties of in-line valves and their operators are included in the piping structural models. The valve and operator mass is lumped at their respective center of gravity. Branch lines are included in the piping models unless they meet uncoupling criteria based on the

elative moments of inertia of the branch line and main line.

These criteria ensure that omission of branch lines COM-02-039-6 Revision 0 6-2.50 nutmh

.. _ _ = - -.. i will not influence the behavior of the main line. The ~ - evaluation of the uncoupled branch lines has been s l considered in Section 6-3.0. f i 'i-i i - l-1 1 r i i i. i I i-1 f r t i l@ i j. e 6 1 l, I t i t L i i I t 9 COM-02-039-6' - Revision 0 '6-2.51 '* w vnW -- , ww r-re+ er ww ' w m e -, - mm.... m-aorm mw,-- eem w-

  • mem-*<-mmm-msew*---w--=

-m-<-wem-

t.asswo NCCE lQ [Nop Ay,ggggg) G NODE ATTACHED To Tom RUPTURE @ ANCHOR DE l-1527. a*-1.X ) SUFFORT otRECTioN > UNEID ,g 20s lY X [NoRTN) 19 5 190 >2ts iss h ,220 Z l(.5 I l-ISIS-S*.Lx /.'8 iso 0.f / / iss i2So i 2SI 5'* h ,2% X112 VMuum E!REAKER 5( 4 20 '0, J 8 o 25 r SL' 245 o . 4 #c1- '0 2so< ,g b-151+ -y-i.x 8"85' cap f Nf /~'b.# 27 5 M / oso 28. Figure 6-2.4-1 TAP SYSTEM STRUCTURAL MODEL (LINE X-212) coM-02-039-6 Revision 0 6-2.52 nutagh

C\\ 6-2.4.2 Methods of Analysis for SAR and Static Torus (L Displacement Loads 4 The following loads, which are described in Section 6-2.2, represent the SAR loads for which all TAP systems are analyzed. In

addition, analyses are performed for static torus displacement loads due to normal and accident conditions.

J 1. Dead Weight Loads l 2. Seismic Loads 3. Pressure and Temperature Loads 4. Operating Loads I l S. Static Torus Displacement Loads The methods used to analyze the piping systems for the above loads are described as follows: l.. Dead Weight (DW) Loads A static analysis is performed for the uniformly distributed and concentrated weight

loads, including insulation and pipe contents, applied to the TAP systems.

!O COM-02-039-6 Revision 0 6-2.53 -,-.-a

2. Seismic Loads a. OBE Inertia (OBEY) Loads: A dynamic analysis is performed independently for the N-S and E-W directions using the uniform response spectra method. A constant vertical seismic acceleration is included in both cases.

Response

spectra generated for 1/2% of critical damping are used in accordance with the safety analysis report. All modes up to 33 hertz are considered in calculating the peak response of the piping system. b. OBE Displacement (OBED) Loads: A static analysis is performed independently for the N-S and E-W direction only since the vertical displacements are negligible. The relative i anchor displacements at the torus penetration l and reactor auxiliary building slabs are i conservatively considered to be out of phase. c. SSE Inertia (SSEy) Loads: Consistent with the definition of the loading in Section 2.2.1, the OBEY results are doubled to obtain the SSE results. 1 O COM-02-039-6 Revision 0 6-2.54 nutp_qh

~ i d. SSE Displacement (SSED) Loads: Consistent with the definition of the loading in Section 2.2.1, OBE results are doubled to obtain D SSED results. The methodology used to combine modal responses and spatial components in the seismic analysis is in accordance with the SAR (Reference 4). The individual modal responses are combined by the SRSS method. The seismic analysis is performed independently for each of the two horizontal directions, N-S and E-W, and for the vertical direction. The N-S and the E-W responses are [ separately combined with the vertical response by the absolute sum method and the larger result is used. 3. Pressure and Temperature Loads a. Pressure Loads: The -effects of maximum operating pressure (Po) and design pressure (P) are evaluated utilizing the techniques described in Subsection NC-3650 of the ASME

Code, Section III (Reference 6).

Table 6-2.2-3 lists the values of P and P used in g the analysis. %s COM-02-039-6 Revision 0 6-2.55 nutagh

b. Temperature Loads: A static thermal expan-sion analysis is performed for the piping temperature cases TE and TE1, as described in Table 6-2.2-3. A static analysis is per-formed for anchor movement, as described in Section 6-2.2, at the torus supports and penetrations. 4. Operating (OL) Loads Line operating loads are applied statically using piping end segment thrust loads to the TAP systems, as described in Section 6-2.2.1. 5. Static Torus Displacement Loads The static displacements of the torus at the appropriate TAP penetration location due to torus movement induced by normal (TD) and accident (TD1, TD TD ) condition pressures and enclosed water 2, 3 weight are applied to each piping system as an applied displacement load case. O COM-02-039-6 Revision 0 6-2.56

6-2.4.3 Methods of Analysis for Hydrodynamic Loads Aj Portions of TAP systems internal to the torus are subjected to hydrodynamic impact and drag loads as a result of the SRV discharge and LOCA events discussed in Section 6-2.2.1. The methods used to analyze the piping fdr these loads are described as follows: 4 6. Safety Relief Valve Discharge (OAB) Loads a. Water Jet Impingement Loads: Water jet pres-sure loadings are evaluated by multiplying the pressures by the appropriate submerged piping projected areas to convert them into nodal piping forces. An equivalent static analysis is then performed by multiplying the forces by a value of 2.0, which is the maximum DLF for the rectangular pulse jet i pressure loading. The final analysis results l. are multiplied by a scale factor of 1.5. This value is used to account for the effects of multimode response. O) ( .COM-02-039-6 Revision 0 6-2.57 nutagh

b. Air Bubble Drag Loads: An equivalent static analysis of the piping systems is performed to evaluate the acceleration drag and standard drag forces imparted to the submerged portions of piping. The applied equivalent static loads represent the peak dynamic loads from the loading transient multiplied by the peak dynamic load factor (DLF) of the structure within the load frequency range (1 to 50 hertz). The final analysis results are multiplied by a scale factor of 1.5, as described in Load Case 6a. This value is used to account for the effects of multimode response. 7. Vent Clearing (VCL and VCLO) Loads a. LOCA Water Jet Impingement Loads: An equiva-lent static analysis method is used to apply the LOCA jet loads to submerged portions of the piping models. For a given jet loading time-history, the peak DLF of the structure within the load frequency range (1 to 50 hertz) is determined. The equivalent static load applied to each segment of piping is equal to the product of the peak jet load COM-02-039-6 Revision 0 6-2.58 nutggh

section force and the appropriate dynamic load factor. The final analysis results are multiplied by a scale factor of 1.5, as described in Load Case 6a. b. LOCA Air Bubble Drag Loads: An equivalent static analysis is performed to evaluate the acceleration drag and standard drag forces imparted to the submerged portions of the piping. For a given loading time-history, the peak DLF of the structure within the load frequency range (1 to 50 hertz) is deter-mined. A scale factor of 1.5 is applied to the analysis results, as described in Load Case 6a. I 8. Pool Swell (PS and PSO) Loads The method of equivalent static loads is used in analyzing the piping system for the effects of pool swell loads. Since pool swell loads are time-limited pulses with regular shapes, their DLF's are constants ~ and are well defined. The applied equivalent static piping section forces are equal to the peak section forces multiplied by their corresponding dynamic load factors. These .l 'V CoM-02-039-6 Revision 0 6-2.59 l nutgg;b

section forces are converted into nodal forces for application to the piping models. a. Impact and Drag Loads: Horizontal torus internal piping above the elevation of the downcomers is subjected to pool swell impact and drag loads. The impact and drag pressure transients are distributed uniformly over the affected piping surface. The load is applied in the upward direction most critical to the piping within the specified load directional range. The impact plus drag loading tran-sient consists of a sharp triangular impulse followed by a rectangular drag loading. The combined DLF value for this transient is 1.7. In some cases where the impact load component does not exist, a DLF of 2.0 is utilized to account for the drag load component. l b. Froth Impingement Loads: The pool swell froth loading time-history is a rectangular pulse which has a maximum DLF value of 2.0. Froth impingement loads are applied to piping located within the suppression chamber, as defined in Volume 1. O COM-02-039-6 Revision 0 6-2.60 nutE_h.

h [O c. Pool Fallback Loads: Following the pool swell transient, the pool water falls back to its original level, creating drag loads on piping inside the torus. The fallback loading is a triangular pulse and is applied statically to the piping using a DLF value of 1.25. The final pool swell loading analysis results for each of the above loads are multiplied by a scale factor of 1.5, as described in Load Case 6a. 9. Condensation Oscillation Loads O As discussed in Section 2.2.1, the CO drag force is composed of both velocity and acceleration drag 4 components. The drag forces are determined based on the summation of 50 harmonic loading functions. A detailed description of the harmonic loading functions as well as the procedures used in applying the loads are discussed in. Volume 1. Once the' amplitudes of the drag forces for a given f piping system have been determined, they are I l converted to the PISTAR coordinate system and applied as PISTAR nodal forces. 1 '.%s COM-02-039 ! Revision 0 6-2.61 nutgrJ) a

Given the harmonic nodal force time-histories for acceleration and standard drag as well as the results of a PISTAR mode-frequency analysis for each piping

system, a

steady-state response calculatica is carried out using the modal superposition method. The FSI effect is also considered in the analysis. The FSI effect is superimposed on results from the PISTAR mode frequency analysis. 10. Chugging Loads a. Pre-Chug (PCHUG) Loads: As described in Section 6-2.2.1, the pre-chug load definition is a single harmonic velocity and accelera-tion drag loading. The defined loading amplitude is

  • 2
psi, and the loading frequency is in the 6.9 to 9.5 hertz range.

The specific frequency chosen for performing the piping analysis is the frequency that is most critical for the particular piping system being evaluated. Details of the loading definition are described in Volume 1. The pre-chug loading is applied to the piping models as a nodal

force, and a

dynamic COM-02-039-6 Revision 0 6-2.62 nutgg.hb

J h i: 2 I response analysis is carried out to obtain maximum system response. Torus FSI effects are also included in the analysis. I b. Post-Chug (CHUG) Loads: The post-chug load-ing definition is similar to that for CO in that it is defined as a 50 harmonic forcing function. The piping analysis procedures for post-chug loads are therefore the same as for I the CO loads described above. 6 t I l I i COM-02-039-6 Revision 0 6-2.63 l nutggb

6-2.4.4 Methods of Analysis for Torus Motions 11. Torus Motion Loads Torus motion

loads, as discussed in Section 6-2.2.1, are considered for the analysis of all torus attached piping systems.

This section describes the methods of analysis for the following torus motion load cases: QABD) a. SRV Torus Motion (QABy, b. Pool Swell Torus Motion (PSy and PSOr, D PS l and PSOp) c. Condensation Oscillation Torus Motion (coy, COD) PCHUGD) d. Pre-Chug Torus Motion (PCHUGI, CHUG I e. Post-Chug Torus Motion (CHUGy, D The coupling analysis method and/or multiple i 1 response spectrum method (MRSM) are utilized to obtain piping response for the five torus motion j load cases. The methods of analysis for each l torus motion event are described in the following paragraphs. COM-02-039-6 Revision 0 6-2.64 nutagh

Coupling Analysis The conventional method for performing dynamic l analyses of structures and supported equipment such as piping systems' is to perform independent uncoupled dynamic analyses of the containment and of the supported piping. A detailed model of the structure is first developed. This model often accounts for the mass of the supported piping but not its dynamic characteristics. A dynamic analysis of the uncoupled containment. is performed, and the response time-history at the I attachment point of the supported piping is obtained. This response time-history or the corresponding spectra is then used to calculate the response of an-uncoupled dynamic model of the piping. This conventional method of analysis is termed an uncoupled analysis because the dynamic. i models of the containment and the piping are never directly coupled or combined. Conventional uncoupled analyses tend to-over-i estimate the response of the. supported piping. The. response at the piping. attachment point obtained from the uncoupled containment analysis will: include' the contribution of all' uncoupled l ( COM-02-039-6 Revision-0 6-2.65 1, m ---- ,-...n, ,,,,-m-,.n.a. ,.n --,.-,~,,.v..,.,,-,,-._...,.-,...+-,.-,,-,,,,--,--~...,_.l-.----n

containment modes excited by the input time-history. The spectra from this time-history will show amplified spectral peaks at each of the significant uncoupled containment modes. If the uncoupled piping model has natural modes near these spectral peaks, then the uncoupled contain-ment response will engender an amplified response of the piping system. However, when the uncoupled containment and piping natural modes are nearly the

same, the piping system will in reality inhibit the response of the containment at that frequency, and the torus response will be less than that obtained from an uncoupled analysis.

This effect is particularly significant for the SRV, pre-chug, and CO torus motion analyses, since the LDR requires " tuning" the loading frequencies to the critical piping response frequencies. This overestimation of piping response may be corrected by performing a coupled analysis, in which a single dynamic model including both the torus and piping is used. In this way, the coupling effects between the torus and piping are automatically included.

However, a

coupled analysis of this type is not practical for the majority of the tap systems. For these systems, a COM-02-039-6 i Revision 0 6-2.66 nutagh r

G computer program has been developed which is used [V ) to incorporate the coupling effects into the results of the uncoupled torus and piping analyses. The program has been formulated in the time domain. For loads such as pool swell, where the torus load definition is defined in the time

domain, the coupling program may be applied directly.

For LOCA-related loads such as CO and j

chugging, which are defined in the frequency 4
domain, the coupling program is not directly applicable, since it is formulated in the time domain.

The coupling program is also impractical for performing analyses for SRV loads due to the O wide range of forcing frequencies involved and to '\\ the number of separate load cases that must be considered in addressing the LDR " tuning" requirement. 4 Transfer Function Approach In order to facilitate application of the coupling methods for the CO,. chugging, and SRV loads, a transfer function approach, based on a white noise time-history analysis, is utilized in conjunction with the coupling program. This method provides j ( for determination of the critical coupled response 't sj. COM-02-039-6 Revision 0 6-2.67

frequencies of the piping systems, which are in turn used in selecting the appropriate frequencies of the applied loadings. The transfer functions relate piping system response to torus shell forcing functions, and are calculated in the time domain by applying to the mathematical model of the torus a white noise time-history with a spatial distribution equivalent to that specified for the particular hydrodynamic load under consideration. The resulting uncoupled torus shell motions are then used in conjunction with piping and torus modal characteristics to obtain the coupled piping responses in the time domain. These time domain piping responses, together with the white noise time-history that is employed for the torus forcing function, are then transformed into the frequency domain using standard fast-fourier transform methods. The transfer function of the piping system is then obtained by dividing the coupled white noise response by the white noise input in the frequency domain. The critical piping response frequencies are then obtained by examining the relative magnitudes of the transfer function peaks. COM-02-039-6 Revision 0 6-2.68 nutggh

d [( Knowing the critical piping response frequencies, appropriate frequencies from the range of CO, chugging, and SRV load frequencies can be selected to determine the forcing functions to be applied to the torus. The forcing function time-histories are then transformed into the frequency domain and multiplied by the transfer function to obtain piping system responses in the frequency domain which, in turn, are transformed back into the time domain to conclude the process. For CO and post-chug

loads, it is also necessary to sum the responses from each of the 50 harmonics that must O

be considered. The flow chart provided in Figure 6-2.4-2 shows the basic steps involved in performing the coupled / transfer function TAP analysis. The specific coupling analysis procedure used for each category of torus motions loads is described as follows: l t Os .COM-02-039-6 Revision 0 6-2.69 l nutaph

a. SRV Torus Motion 1. Using the mathematical model of the TAP systems described in Section 6-2.4.1, the uncoupled piping dynamic character-istics (mode shapes and frequencies) are determined using the PISTAR piping analysis program. All modes up to 60 hertz have been considered in the analysis. 2. Similarly, using the finite element model of a 1/32 segment of the suppression chamber as described in Volume 2, the torus dynamic characteristics (mode shapes and frequencies) are determined. The STARDYNE computer program is used for [ this analysis. t 3. The time-history response of the suppression chamber at the torus-pipe I intersection due to a band limited white noise time-history is determined. The STARDYNE computer program is used for this analysis. COM-02-039-6 Revision 0 6-2.70 nutgqh

4. Using information derived in Steps 1 (% through 3 above, the coupled response of the piping system for each mode due to the white noise input is determined using the coupling computer program. 5. Using the modal superposition technique, the modal responses of the piping system obtained from Step 4 are used in calcu-lating the response of the piping system due to the white noise input. The static response of the piping at high frequencies is accounted for by use of a pseudomode computer program. i 6. Transformation of the white noise response time-history from Step 5 and the input white noise time-history to the frequency domain is then performed using the fast-fourier transform method. 7. The transfer function for each component l I of the piping system is calculated by dividing the white noise response by the white noise input. in the frequency domain. ['N l COM-02-039-6 Revision 0 6-2.71 nuttgb

8. Critical piping frequencies within the prescribed SRV load frequency range are selected at the transfer function peaks. 9. The torus safety relief valve bubble loading is generated by " tuning" the SRV bubble pressure frequency to the piping critical frequencies obtained in Step 8 above. 10. The " tuned" torus shell load time-histories are transformed into the i l l frequency domain using the fast-fourier [ transform method. 11. Piping response in the frequeacy domain for each piping component is computed by multiplying the transfer function (determined in Step 7) times the torus t shell load in the frequency domain l obtained in Step 10. In this step, the response is scaled down based on results from the SRV alternate analysis method, described in Volume 1, which calibrates the results of the coupled fluid-torus analysis to in-plant SRV test data. O COM-02-039-6 Revision 0 6-2.72 nutggj)

d 12. Final piping time-history responses are derived from piping response in the frequency domain (Step 11) by using the inverse fast-fourier transform method. t f 13. The peak of the time-history response is selected for the piping stress evaluation. 1 b. Pool Swell Torus Motion 1 1. Uncoupled torus and TAP system mode shapes and frequencies, as described

above, are again utilized.

) i 2. The actual time-history response of the suppression chamber is determined at the torus-pipe intersection due to the pool swell pressure time-history load. 3. The coupled response of the' piping system for. each mode due to the pool swell load input is 4 i determined using the coupling computer i . program. l \\ .COM-02-039-6 -Revision 0 6-2.73 nutagh

4. Using the modal superposition technique, the modal response of the piping system is obtained and is used in calculating the final response time-history. 5. The peak of the time-history response is selected for the piping stress evaluation. c. Condensation Oscillation and Chugging Torus Motions 1. Transfer functions relating piping responses to CO, pre-chug, and post-chug torus internal pressures are obtained in a manner similar to Steps 1 through 7, described above for SRV torus motion. 2. Calculations are then performed to obtain piping responses in the frequency domain utilizing the fast-fourier technique and applying amplitudes of pressure versus frequency for the CO and post-chug load cases. The pressure amplitudes and frequencies utilized for CO and post-chug loads are defined in Volume 1. The pre-chug load is defined as a single harmonic with an O COM-02-039-6 Revision 0 6-2.74 nutgqh

amplitude of *2 psi in the frequency range of 6.9 to 9.5 hertz. The selection of the critical piping frequency in this range is based on the transfer function peak which occurs most frequently. 3. For CO and post-chug, the frequency domain harmonic response is conservatively deter-mined for each of the 50 defined harmonic forcing frequencies as the product of the pressure amplitude and the peak of the transfer function in each frequency band. 4. The final time domain response for the CO load case is taken as 1.15 times the direct sum of 50 harmonic responses which are randomly phased by introduction of a set of 50 random phase angles. Cumulative distribu-tion functions of analytical and test data form the basis for this random phasing. A 50% non-exceedance probability (NEP) with 90% confidence is achieved as a result of this method. 5. For the post-chug case, the final time domain response is obtained as the absolute sum of COM-02-039-6 Revision 0 6-2.75

the 50 harmonic responses. The phase angles are set to zero in this case. 6. The peak magnitude of the time domain response for CO, pre-chug, and post-chug load cases is selected for the piping stress evaluation. Multiple Response Spectrum Method (MRSM) Analysis An alternate method of analysis was utilized to analyze for torus motions on selected piping systems in lieu of the coupling method described above. The alternate method, termed the multiple response spectrum method, is performed using the PISTAR computer program. The MRSM method of analysis calculates the dynamic responses of the piping system due to a single support motion input. Thia method is used to analyze piping systems attached to the ECCS suction header. The ECCS suction header is analyzed using coupling analysis procedures outlined in this section. Then response spectra in the three orthogonal translational directions are generated at a I location where piping systems are attached to the ECCS header. The inertial component of the torus l O COM-02-039-6 Revision 0 6-2.76 nutggb

i !j' 1 i l input motion is analyzed using these response l spectrum curves. The displacement components of i the torus input motion are analyzed by applying static end displacement loads to the piping at the f attachment point. l i 4 i i I i l l i i 1. r I l I 4 h I i. i i i-i I l i t i i 1 ,COM-02-039-6 Revision 0 6-2.77 t -f a.

STARDYNE PISTAR TORUS PIPING MODEL MODEL o o MODAL PROPERTIES MODE WHITE NOISE RESPONSE PROPERTIES TIME-HISTORY COUPLING PROGRAM o COUPLED PITING RES.ONSE o TRANSFER RESPONSE TO FREQUENCY DOMAIN COMPUTE TRANSFER FUNCTION DETERMINE CRITICAL PIPING RESPONSE FREQUENCIES SELECT TORUS MOTION CRITICAL LOADING FREQUENCIES COMPUTE PIPING RESPONSES AT CRITICAL LOAD FREQUENCIES USING TRANSFER FUNCTIONS 7 PERFORM PIPING STRESS EVALUATION Figure 6-2.4-2 TAP SYSTEM COUPLED / TRANSFER FUNCTION ANALYSIS PROCEDURE COM-02-039-6 Revision 0 6-2.78 nutggh_ s

6-2.4.5 Fatigue Evaluation Section 4.3.3.2 of NUREG-0661 requires that a fatigue evaluation of the SRV and torus attached piping be performed for all loading conditions except pool swell. The Mark I Owners Group prepared and submitted a generic fatigue evaluation report (Reference 7) to the i NRC in late 1982. The report addressed fatigue on a generic basis using actual piping analysis results from f. essentially all Mark I plants. The resulting cumulative usage factors are below 0.5, demonstrating that further plant unique fatigue evaluations are not warranted. Therefore, the Quad Cities Unit 1 TAP is qualified based on this generic evaluation. LO COM-02-039-6 Revision 0 6-2.79 l nutagh

6-2.5 Analysis Results The analytical results for the large bore TAP evaluation are summarized in this section. The maximum piping stresses resulting from governing load combinations for highly stressed locations on each large bore TAP line and for small diameter torus internal lines, are presented in Table 6-2.5-1. The maximum stresses for each service level are listed along with the associated Code equations and allowable stress values. Fatigue evaluations for the TAP lines have been performed generically as' described in Section 6-2.4.5. The Quad Cities Unit 1 TAP is qualified for fatigue effects based on this generic evaluation. In summary, the results show that the design of the large bore TAP systems are adequate for the loads, load combinations, and acceptance criteria limits specified j in NUREG-0661 (Reference 1) and the PUAAG (Reference l 5). l COM-02-039-6 Revision 0 6-2.80 nutagh

O O gQ Table 6-2.5-1 < :s ' NALYSIS RESULTS FOR TORUS ATTACHED PIPING STRESS $o A P. N O I i Dow 0y SERVICE LEVEL A B C D SECONDARY ASME CODE EQUATION 8 9 9 9 10 22.50/37.50(2) ALIDNABLE STRESS (ksi) ggg ggg ggg ggg III/43.75 (1) (2) 17.50 21.00 31.50 42.00 26.25 SYSTEM DESCRIPTION MAXIMUM STRESS (ksi) PRESSURE SUPPRESSION 2.23 2.55 3.94 10.25 19.95 l ECCS SUCTION HEADER 7.18 17.53 29.64 39.68 8.59 VACUUN RELIEF 6.72 14.33 24.97 24.97 25.48(2) i MIR TEST LINE AND SPRAY HEADER 4.07 17.09 25.65 35.77 34.75(2) DISCHARCE FROM PUMP 1A/lB M MIR TEST LINE AND SPRAY HEADER 8.24 15.46 24.80 30.99 22*37 DISCHARGE PROM PUMP IC/ID m RCIC TURBINE EXHAUST 5.73 13.25 20.82 31.90 16.24 HPCI TURBINE EXHAUST 7.30 13.48 17.62 20.00 20.31 HPCI POT DRAIN 1.11 12.87 15.02 17.69 4.07 RCIC POT DRAIN 1.11 12.87 15.02-17.69 4.07 RHR 1 A/lB PUMP SUCTION 2.48 18.00 25.67 34.80 37.06(2) RHR IC/1D PUFP SUCTION 10.69 13.66 27.00 33.78 36.45(2) CORE SPRAY 1A/IB PUMP SUCTION 6.68 16.43 26.24 30.44 37,3g(2) HPCI PUMP SUCTION 2.06 9.20 21.19 21.32 20.47 RCIC PUMP SUCTION 1,81 12.81 26.60 34.51 18.66 ) (1) FOR ECCS SUCTION HEADER. (2) EQUATION 11 IS USED IN PLACE OF EQUATION 10.

f C-6-3.0 SMALL BORE PIPING An evaluation of each of the NUREG-0661 (Reference 1) requirements which affect the design adequacy of the Quad Cities Unit 1 small bore piping (SBP) is presented in the following sections. The general criteria used in this evaluation are contained in Volume 1 of this PUAR. 4 The components of the SBP which are examined are described in Section 6-3.1. The loads and load combinations for which the SBP are evaluated are described and presented in Section 6-3.2. The acceptance limits to which the analysis results are compared are discussed and presented in Section 6-3.3. The analysis methodologies used to evaluate the effects of the loads and load combinations on the SBP are discussed in Section 6-3.4. The analysis results and the corresponding design margins are presented in Section 6-3.5. 1 l \\~ COM-02-039-6 6-3.1 Revision 0 nutagh

6-3.1 Component Description The SBP lines for the Quad Cities Unit 1 plant unique analysis (PUA) falls into the following five categories. 1. Small bore piping lines which meet the 10% exclusion criteria 2. Cantilevered lines 3. Small bore piping with flex loops 4. Other torus external small bore lines 5. Torus internal small bore lines of the 97 small bore lines, 51 initiate from large bore piping lines that meet the 10% exclusion criteria; therefore, they are not evaluated. There are 15 lines cantilevered f rom the torus or large bore TAP which are evaluated. Table 6-3.1-1 provides typical SBP systems design data. Figure 6-3.1-1 shows two typical cantilever lines. l l Eighteen small bore lines are attached directly to the torus or large bore torus attached piping (TAP). Evaluation of these systems included a flex loop installed to reduce the effects of torus motion on the piping systems. Downstream of the flex loop is an anchor separating the remaining SBP from the effects of COM-02-039-6 6-3.2 Revision 0 ritit

E Mark I loads. Figure 6-3.1-2 shows a typical flex loop installation. l ) Thirteen other types of small bore lines range in size from 1/2" to 2" Schedule 60, and 2-1/2" to 4" Schedule 40 pipe supported by rigid struts, rods, guides, and spring supports. These lines are either attached to the torus or other large bore lines connected to the

torus, and serve a multitude of functions such as nitrogen purges, RIIR pump bypasses, and HPCI minimum i

flow returns. Figure 6-3.1-3 provides an example of i these lines. l l i i-l COM-02-039-6 -3.3 f Revision 0-I

Table 6-3.1-1 SMALL BORE PIPING - SYSTEM DESIGN DATA DESIGN DESIGN NORMAL NORMAL SYSTM PRESSURE TEMPERATURE PRESSURE TEMPERATURE TYPE (psi) (*F) (psi) (*F) CANTILEVERS 415 400 180 165 PIPING 415 400 180 165 FLEX LOOPS 170 300 155 280 0 COM-02-039-6 Revision 0 6-3.4 nutggh

O O C)< ><l-3 G" SY2 4" d I t i -- C __ 5' ; _ SPz" _ 4" h ANCWCR l l Figure 6-3.1-1 TYPICAL CANTILEVERED VENT OR DRAIN CoM-02-039-6 l Revision 0 6-3.5 nutggh

l I O t 4 Tonus P>- ETRATION a* } a O n l,9 i n '/ s '. o, ,A i @ ANCHOR l Figure 6-3.1-2 TYPICAL FLEX LOOP INSTALLATION COM-02-039-6 Revision 0 6-3.6 nutggb

O Sk2_ 5_ l'-3" 2'- 3 k + j ss N= l e,, 3+ D, \\9,, g SUPPORT SI-CIRECTIONAL TORUS PENETRATION b ~ s,y- \\' 8! \\_ ~ ~ " *A,, R % y _- 63-s, Figure 6-3.1-3 TYPICAL SMALL BORE PIPING LINE COM-02-039-6 Revision 0 6-3.7 nutggh

i 6-3.2 Loads and Load Combinations The loads for which the Quad Cities Unit 1 SBP is designed are defined in NUREG-0661 on a generic basis for all Mark I plants. The methodology used to develop plant unique loads for each load defined in NUREG-0661 is discussed in Volume 1. The results of applying the methodology to develop specific values for each of the controlling loads which act on the SBP are discussed and presented in Section 6-3.2.1. Using the event combinations and event sequencing defined in NUREG-0661 and discussed in Volume 1, the governing load combinations which affect the SBP are formulated. The load colabina tions are discussed and presented in Section 6-3.2.2. t COM-02-039-6 6-3.8 Revision 0 nutggb

[ 6-3.2.1 Loads The loads acting on the SBP are categorized as follows: 1. Dead Weight Loads 2. Seismic Loads 3. Pressure and Temperature Loads 4 i 4. Safety Relief Valve Discharge Loads 5. Pool Swell Loads 6. Condensation Oscillation Loads 4 i 7. Chugging Loads i Loads in Categories 1 and 3 are defined in Categories 1 and 3 in Section 6-2.2.1. Table 6-3.1-1 provides 1 further definition of Category 3 loads for typical SBP systems. Category 2 loads are defined in Section 6-3.4.1. Loads in Categories 4 through 7 are defined in Section 6-2.2.1. Small bore piping attached to the torus experiences LOCA-induced and SRV discharge-induced loadings ~ directly from the torus response to these loads. Small bore piping attached to large bore TAP lines experiences these loads indirectly, from the response of the large bore piping to the input response of the torus. 1 COM-02-039-6 6-3.9 Revision 0

Not all of the loads defined in NUREG-0661 need be evaluated, since some are enveloped by others or have a negligible effect on the piping. Only those loads which maximize the piping response and lead to controlling stresses are examined and discussed. These loads are referred to as governing loads in subsequent discussions. O COM-02-039-6 6-3.10 Revision 0 nutggh

i J 6-3.2.2 Load Combinations j l t i The loads for which the SBP are evaluated are presented i l in Section 6-3.2.1. The NUREG-0661 criteria for i grouping these loads into load combinations are discussed in Volume 1. i Load combinations specified for the SBP are the same as l those specified for the large bore TAP in Table i 6-2.2-5. Several of the load combinations presented in ] these tables do not result in controlling stresses in i I i the SBP, and are not evaluated. Load combinations ( i ) which contain hydrotest loadings are not evaluated l since these loadings have a negligible effect on the small bore piping. i i The governing load combinations for the SBP as j described above have been considered in the analytical i methods described in Section 6-3.4. t l l \\ ~COM-02-039-6 6-3.11 Revision 0 nutagh

6-3.3 Acceptance Criteria The acceptance criteria defined in NUREG-0661 on which the Quad Cities Unit 1 SBP analysis is based are discussed in Volume 1. The acceptance criteria follow the rules contained in the ASME Code, Section III, Division 1, 1977 Summer Addenda for Class 2 piping (Reference 6). The corresponding service level limits and allowable stresses are also consistent with the requirements of the PUAAG (Reference 5) and the ASME Code (Reference 6). j The SBP systems are evaluated in accordance with the requirements for piping systems contained in Subsection NC of the ASME Code. l l l Cott-02-039-6 6-3.12 Revision 0 nutggh

.L i I 6-3.4 Methods of Analysis l l i i l The gaverning load combinations for which the Quad i t Cities Unit 1 SBP is evaluated are presented in Section l l f 6-3.2.2. The methodology used to evaluate the SBP for the effects of these loads is discussed in Section 6-3.4.1. t i i h I h j l r l' s t 6 COM-02-039-6 6-3.13 Revision 0

6-3.4.1 Analysis for Major Loads The SBP systems are evaluated for the effects of the loads discussed in Section 6-3.2.1 using several different methods, depending on the type of system configuration. A description of methods used for each type of configuration follows, a. Cantilevered Drains and Vents: Section 6-3.1 pro-vides a description of the system, which is shown in Figure 6-3.1-1. A beam model of the system is used to calculate the natural frequency using standard beam formulations of the system. A dynamic load factor is calculated based upon the calculated system natural frequency and the predominant loading frequency. An equivalent static analysis is performed using loads and load combinations defined in Sections 6-3.2.1 and 6-3.2.2. l b. SBP .ir. r with Flex Loops: Flex loops, shown in l S i

1. r *

'-3.1-2, are designed for locations of 16rge input displacements. The loops have resonant frequencies outside the critical 1 frequency range of the input motion. An anchor isolates the - remainder af the piping system from COM-02-039-6 6-3.14 Revision 0 nutggh

'the Mark I loads. Since the flex loop orientation U is critical in determining stresses within the loop, a method for analyzing stress in the loop for a given location is necessary. To do this, 4 the coefficient method was developed. Stresses ae determined in the loop when a reference load is applied to each direction of the six DOF's at the penetration,.or loaded point. For the static

case, the reference load is defined as a unit displacement or unit rotation, depending on the nature of the loading.

For the dynamic loading, -the reference load is defined by the motion whose response spectrum envelops other response spectra obtained at other locations on the suppression chamber in terms of frequency content. c. Other Piping Systems: Section 6-3.1 provides a description of the systems shown in Figure 6-3.1-3. A beam model is generated and a frequency analysis is performed in which all modes of vibration in the range of 0 to 60 hertz are extracted. Selected lines underwent in situ testing to determine the dynamic characteristics of the SBP systems. The hammer impact method is .used for excitation during the dynamic test. l-Modal parameters, i.e., resonant frequencies and ' (O~/ COM-02-039-6 6-3.15 Revision 0 nutggh

modal

damping, are extracted using the ino l t i-degree of freedom curve fit algorithm.

A dynamic load factor is calculated based on the resulting first natural frequency. An equivalent static analysis is performed using a finite element model. The specific treatment of each load in each load category identified in Section 6-3.2.1 is discussed in the following paragraphs. 1. Dead Weight (DW) Loads A static analysis is performed for a unit vertical acceleration applied to the welght of steel and the weight of water contained inside the small bore piping. 2. Seismic Loads a. OBE Inertia (OBEY) Loads: A response spectra j analysis is performed in the horizontal directions and a 0.08g maximum acceleration applied vertically to the combined weight of steel and water in the analytical model. O COM-02-039-6 6-3.16 Revision 0

j b. OBE Displacement (OBED) Loads: A static . '%/ analysis is performed for the horizontal and vertical OBE displacements as defined in the safety analysis report. c. SSE Inertia (SSE ) Loads: A response spectra y i' analysis is performed for the horizontal directions and a 0.16g maximum vertical acceleration applied to the combined weight of steel and water in the analytical model, d. SSE Displacement (SSED) Loads: A static analysis is performed for the horizontal and vertical SSE displacments as defined in the safety analysis report. 3. Pressure and Temperature Loads a. Pressure ( P.3, P) Loads: The effects of these loads on the SBP are evaluated by using the ASME Code piping equations. l b. Temperature (TE, TE ) Loads: A static anal-1 ysis is performed for the TE and TEl tempera-ture cases, with the load applied uniformly to the small bore piping. The temperatures un/ iw .COM-02-039-6 6-3.17 Revision 0 nutagh i

applied to the SBP are equal to the maximum pipe temperature. An additional static analysis is performed for the effects of thermal anchor movements at the attachment of the SBP to the sup-pression chamber for normal operating and accident conditions. 4. Safety Relief Valve Discharge (QAB) Loads A multiple response spectra analysis is performed for the loads defined in Section 6-2.2.1. 5. Pool Swell (PS) Loads A multiple response spectra analysis is performed for the pool swell pressure transients defined in Section 6-2.2.1. 6. Condensation Oscillation Loads l A multiple response spectra analysis is performed for the loads defined in Section 6-2.2.1. l l COM-02-039-6 6-3.18 Revision 0 nutp_qh

7. Chugging Loads a. Pre-Chug (PCHUG) Loads: Post-chug loads bound pre-chug loads. Accordingly, the analysis results for post-chug are used in load combinations which include pre-chug loads. b. Post-Chug (CHUG) Loads: An equivalent static analysis is performed for the loads defined in Section 6-2.2.1. The methodology described in the preceding paragraphs results in conservative values for the SBP stresses for the controlling loads defined in NUREG-0661. Therefore, use of the analysis results obtained by applying this methodology leads to conservative estimates of design margins for the small bore piping. T 'COM-02-039-6 '6-3.19 2 Revision 0

6-3.5 Analysis Results 1 The component descriptions, loads and load combi-nations, acceptance criteria, and analysis methods used in the evaluation of the Quad Cities Unit 1 SBP are presented and discussed in the preceding sections. The results from the evaluation of the SBP are presented in the following paragraphs. Table 6-3.5-1 shows maximum stresses for a typical SBP evaluation resulting from ASME Code piping equations for the controlling load combinations. In summary, the results show that the SBP is adequate for the

loads, load combinations, and acceptance criteria specified in NUREG-0661 (Reference 1) and the PUAAG (Reference 5).

i I l COM-02-039-6 6-3.20 Revision 0 nutggh

h Table 6-3.5-1 GOVERNING SMALL BORE PIPING STRESSES FOR CONTROLLING LOAD COMBINATIONS LEVEL A LEVEL B LEVEL C LEVEL D ALLOWABLE STRESS (psi) SYSTEM E 37,500 18,000 27,000 36,000 MAXIMUM STRESS (psi) CANTILEVERS N/A 13,385 16,912 l 25,571 PIPING 32,035 17,300 24,500 35,200 FLEX LOOPS 20,000 17,885 22,150 32,527 N O v COM-02-039-6 Revision 0 6-3.21 nutggj)

6-4.0 PIPING SUPPORTS An evaluation of the NUREG-0661 (Reference 1) require-ments related to the design adequacy of the Quad Cities Unit 1 piping supports is presented in the following sections. The general criteria used in this evaluation are contained in Volume 1 of this PUAR. The piping supports are described in Section 6-4.1. Tne loads and load combinations for the piping supports are described in Section 6-4.2. The acceptance limits to compare analysis results and the analysis method-ologies to evaluate the effects of the loads and load combinations on the piping supports are discussed in G Section 6-4.3. The analysis results are presented in Section 6-4.4. O COM-02-039-6 6-4.1 Revision 0 nutE_h.

6-4.1 Component Description External TAP lines are supported by U-bolts, rod hangers, spring hangers, rigid struts, guides, anchors, and snubbers attached to building walls or slabs using structural steel frames and baseplates or directly to the main structural steel in the building. Figures 6-2.1-2 and 6-2.1-3 show typical TAP supports outside the suppression chamber. Torus internal piping is generally supported by rigid structural steel supports attached directly to the torus shell or ring girders, as shown in Figure 6-2.1-5. An example of a TAP support outside the suppression chamber consists of a pipe clamp attached to a rigid strut, which is welded to a steel baseplate anchored to the building structure with wedge-type anchor bolts. These components are designed and qualified by the manufacturers for specific load magnitudes. l For the addition of piping supports and the modification to existing piping supports, the standard l component pipe support hardware and respective manufacturers include: rigid

struts, clamps, and springs - Elcen Metal Products Co. and NPS Industries, COM-02-039-6 6-4.2 Revision 0 nutggh

. _ _ _ _ _. ~ _. L 'Inc.; -mechanical snubbers'and clamps - Bergen-Paterson Pipe Support Corp.;. anchor bolts ITT Phillips Drill

Division, Hilti, Inc.

and Drillco Devices Limited. ? Typically,- pipe clamps are fabricated from ASTM A36 steel plates which are ~ connected with A307 carbon steel bolts. Rigid struts are usually constructed of ASTM A106, Grade B pipe of various diameters and schedules. Base plates are cut from ASTM A36 carbon steel of various thicknesses. Anchor bolts are wedge-type or ]. - undercut type and of various diameters and lengths. f Integral attachments (lugs, trunnions, and pads) welded to the pipe pressure boundary are used where necessary to provide shear resistance between the ' pipe clamp and piping or to anchor the piping system. i Torus attached piping supports connected to the torus shell or ring ' girders ins'ide the suppression chamber are generally made from ASTM A516, Grade 70 carbon steel plate and ASTM A516 pipe, i' b f l. 'COM-02-039-6 6-4.3 l ' Revision 0 i

6-4.2 Loads and Load Combinations The loads for which the Quad cities Unit 1 TAP supports are designed are defined in NUREG-0661 on a generic basis for all Mark I plants. The methodology used to develop plant unique TAP loads for each load defined in NUREG-0661 is discussed in Volume 1. The loads acting on the piping supports outside the suppression chamber are transmitted via the response of the piping to loads defined in Sections 6-2,2.1 and 6-3.2.1. Piping supports inside the suppression chamber experience these same loads, with the addition of hydrodynamic impact and drag loads as defined in Section 6-2.2.1 for large bore torus attached piping. Using the event combinations and event sequencing defined in NUREG-0661 and discussed in Volume 1, the governing load combinations which affect the piping supports are formulated. Table 6-4.2-1 presents the governing load combinations. For external piping supports, loads resulting from dynamic events have been combined using the SRSS method in accordance with References 9 and 10. COM-02-039-6 6-4.4 Revision 0 nutggh

p ] ( J w g' @ Table 6-4.2-1 < 2: rs ta o LOAD COMBINATIONS - TORUS ATTACHED PIPING SUPPORTS g O I Dow O* LOAD COMBINATION IAAD CONDITIONS ( NUMBER S-1 DW + OL + OBE g S-2 DW + OL + QAB + QAB g I$3 S-3 DW S-4 W + OL + QAB + QABg + SSEg S-5 DW + OL + QAB + QABg + PCHUG + PCHUCg S-6 DW + OL + QAB + QABg + CHUC + CHUGg S-7(2) DW + OL + QAB + QABg + SSEg + PCHW + PCHWg S-8(2) DW + OL + QAB + QABg + SSEg + CH W + CH Wg S-9 DW + OL + OBEg + CO + cog s S-loI2I DW + OL + QAB + QABI + SSEI + PS + PSI + VCL A S-11 DW + OL + PSO + PSOg + VCIA S-12 DW + OL + OBEg+ TE + THAM + TD + OBED S-13 DW + OL + QAB + QABg+ TE + THAM + TD + QABD S-14(2) DW + OL + QAB + QABg + PCHUG + PCHUGg+ TEg + THAMg + TD3 III + QABD + PCHUGD S-15(2) DW + OL + QAB + QABg + CHUG + CHUGg+ TEg + THAMg + TD3 N + QABD+ HWD II N + QABD + SSED*'" D S-16 DW + OL + QAB + QABg + SSEg + PCHUG + PCHUCg + TEg + THAMg + TD3 S-17III TE1

  • T"A"1 + TD H) + QABD + SSED + CHUCD DW + OL + QAB + QABI
  • 8881
  • U"UG
  • C"UUI 3

I4I + OBED* O S-18 DW + OL + OBEg + CO + cog + TEg + THAMg + TD3 S-19(2) DW + OL + QAB + QABg + SSEg + PS + PSg + VCL + TEg + THAMg + TD3I43 + QABD

  • S8ID + PSD N + PSO S-20 DW + OL + PSO + PSOg + VCLO TEg + THAMg + TD3 D

S-21 DW + OL + QAB + QAB + SSE + TE + THAM + TD + QABD

  • 88ED y

g (1) SEE SECTION 7-2.2.1 FOR DEFINITION OF INDIVIDUAL LOADS. (2) USE THE IJLRGER OF I4CA AND SSE COMBINED BY THE SRSS METHOD OR LOCA AND OBE COMBINED ABSOLUTELY. j (3) THE HOST SEVERE COMBINATION OF STATIC I4 ADS MUST BE CONSIDERED. g (4) USE THE TD, TD, OR TD CASE WHICHEVER IS MOST SEVERE. g 2 3 (5) APPLICABLE TO NON-WATER LINES ONLY (HYDROFEST LOAD). (6) DYNAMIC LOAD COMBINED BY SRSS (REFERENCE 9) FOR SEIECTED SUPPORTS.

6-4.3 Methods of Analysis and Acceptance Criteria Pipe supports are evaluated using standard linear elastic structural analysis methods, hand calculations, or standard structural analysis computer programs. The resultant component forces and/or stresses are compared to their respective allowable values. Standard component allowables for Levels B, C, and D service limits are supplied by the manufacturer. Allowables for structural members, base plates, and welds are defined in the ASME Code, Section

III, Subsection NF, up to and including the 1977 Summer Addenda and in NUREG-0661.

The application of these allowables is as described in Table 6-4.3-1. Anchor bolt allowables are based on manufacturer's test data in accordance with IEB-79-02 requirements and the American Concrete Institute (ACI) Standard ACI-349-80 (References 11 and 13, respectively). Base plate flexibility and shear-tension interaction are l considered in the anchor bolt evaluation. Integral attachments are evaluated by adding the local stresses in the pipe from each support load combination to the corresponding pipe stress load combination COM-02-039-6 6-4.6 Revision 0 nutggh

listed -in Table 6-2.' 2-5. Allowable stresses are given in ' Table 6-2.3-1. Local stresses are generally calculated using methods described in Welding Research Council Bulletin. WRC-107 and in ASME Code Case N-318 -(References 12 and 14, respectively). .COM-02-039-6 6-4.7 Revision 0

Table 6-4.3-1 PIPE SUPPORT ALLOWABLES LOAD (3) SERVICE LIMITS SERVICE LIMITS COMBINATION STRUCTURAL COMPONENTS STANDARD COMPONENTS S-1 S-2 B B S-3 S-4 S-5 C C S-6 S-7 i S-8 S-9 D D S-10 S-ll S-12 S-13 l S-14 S-15 S-6 3 x B(1,2) D S-17 S-18 l S-19 ( S-20 S-21 (1) LIMITS APPLY TO THE RANGE OF STRESS. COMPRESSIVE STRESS NOT TO EXCEED 2/3 OF THE CRITICAL BUCKLING STRESS. (2) PEAK VALUE OF THE RANGE OF STRESS APPLIES TO ANCHOR BOLTS. (3) SEE TABLE 6-4.2-1 FOR DEFINITION OF THESE LOAD COMBINATIONS. COM-02-039-6 Revision 0 6-4.8 nutggh +

6-4.4 Analysis Results New pipe supports and modifications to existing pipe supports were designed and analyzed to satisfy the 1 acceptance criteria of Section 6-4.3. As a result, the design of the TAP supports for Quad Cities Unit 1 is adequate for the

loads, load combinations, and acceptance criteria limits specified in NUREG-0661 (Reference 1) and substantiates the piping analysis results.

I l 4 l I t i- \\ COM-02-039-6 6-4.9 Revision 0 ,._._..--_.__-....-.~..--..--.,.m .,. _ _ _,. _ _.. ~.... _.

p 6-5.0 EQUIPMENT AND VALVES An evaluation of each of the NUREG-0661 (Reference 1) i i requirements which affect the design adequacy of the i Quad Cities Unit 1 equipment and valves is presented in the following sections. The general criteria used in [. this evaluation are contained in Volume 1 of this PUAR. The components of the equipment and valves which are i examined are described in Section 6-5.1. The loads and i load combinations for which the equipment and valves are evaluated are described and presented in Section 6-5.2. The acceptance limits to which the analysis results are compared and the analysis methodologies used to evaluate the effects of the loads and load i combinations on the equipment and valves are discussed i in Section 6-5.3. The analysis results and the corresponding design margins are presented in Section 6-5.4. i t i n U-COM-02-039-6 6-5.1 Revision 0-nutgrJ)

6-5.1 Component De scription The torus attached piping (TAP) systems include equipment and valves. Three TAP systems required analysis up to connections to pumps and a turbine. All valves included in the piping analytical models as described in Section 6-2.4.1 are considered in this evaluation. The principal valve manufacturers are Crane (gate,

globe, and check valves) and Pratt (butterfly valves).

Valve operator types include Bettis air operators and Limitorque motor operators. O COM-02-039-6 6-5.2 Revision 0 nutggh

6-5.2 Loads and Load Combinations N The loads acting on the valves, valve operators, and equipment nozzles are caused by the response of the piping systems to the loads defined in Sections 6-2.2.1 and 6-3.2.1. These components of the TAP systems are 4 evaluated for.those loading conditions resulting from hydrodynamic responses of the torus due to LOCA and SRV discharge events, as generically defined in NUREG-0661. 1 Equipment nozzle connections are modeled as anchors, as i described in Section 6-2.4.1. Stresses at equipment nozzles and valve body / yoke junction are computed using the governing load combinations listed in Table 6-2.2-5. l l COM-02-039-6 6-5.3 Revision 0 nutg.gb

l 6-5.3 Methods of Analysis and Acceptance Criteria 6-5.3.1 Equipment The equipment described in Section 6-5.1 is qualified by meeting the requirements of one of the following criteria. The pipe stress due to loads defined in NUREG-0661 for load combinations described in Table 6-2.2-5 at the equipment nozzle meets: (1) The 10% rule of Section 6.2.b of the PUAAG (Reference 5), or (2) The pipe stress at the equipment nozzle obtained from the original design (Reference 4). O COM-02-039-6 6-5.4 l Revision 0 nutggh

i 6-5.3.2 valves Check valves and manual valves are modeled in the piping analysis as piping

elements, with increased stiffnesses and masses to represent the properties of the valve body.

Lumped mass models are included in the piping analysis to represent valves with actuators, with the valve mass lumped at the center of gravity. For these valves, the stiffness and mass of the valve i body and stem are considered, along with the eccentricity of the valve operator. Stresses are computed at the weakest sections of the yoke for each dynamic loading given in Table 6-2.2-5. COM-02-039-6 6-5.5 Revision 0 nutggh

6-5.3.3 Acceptance Criteria for Valves The stresses in the valve body and the actuator components will not exceed yield stress. The results of the analysis of valves in TAP systems are presented in Section 6-5.4.2. l O i COM-02-039-6 6-5.6 Revision 0 nutp_qh

6-5.4 Analysis Results '6-5.4.1 Equipment All equipment meets the acceptance criteria described in Section 6-5.3.1. .'COM-02-039-6 .6-5.7 Revision 0

4 6-5.4.2 Valves All active valves in TAP systems are evaluated for the loads and load combinations listed in Table 6-2.2-5. For Quad Cities Unit 1, all active valves meet the acceptance criteria described in Section 6-5.3.3 as the valve body and actuator component stresses are below yield stress. I O l COM-02-039-6 6-5.8 Revision 0 nutggh

D 6-6.0 SUPPRESSION CHAMBER PENETRATIONS An evaluation of the NUREG-0661 requirements which affect the design adequacy of the Quad cities Unit 1 torus attached piping (TAP) penetrations is presented in _the following sections. The general criteria used in this evaluation are contained in Volume 1 of this report. i The components which are analyzed are described in Section 6-6.1. The loads and load combinations for which the penetrations are evaluat'ed are described and presented in Section 6-6.2. The acceptance limits to which the analysis results are compared are discussed ( and presented in Section 6-6.3. The analysis method-ology used to evaluate the effects of the loads and load combinations on the penetrations, including consideration of fatigue

effects, is discussed in Section 6-6.4.

The analysis results are presented in i Section 6-6.5. COM-02-039-6 6-6.1 ) Revision 0 .J nutggh

6-6.1 Component Description The large bore piping suppression chamber penetrations evaluated in this section are numbered and located as shown in Figure 6-1.1-1. The principal components of the penetrations are the nozzles and the insert plates, as shown in Figure 6-6.1-1. The nozzle extends from the outer circumferential pipe weld through the insert plate to the inner circumferential pipe weld or flange. The insert plate provides local reinforcement of the suppression chamber shell near the penetration. Additional reinforcing is provided for many penetra-tiens, as shown in Table 6-6.1-1 and Figures 6-6.1-2 through 6-6.1-4. O Radial penetrations are aligned radially with the suppression chamber segment and are symmetrical about their centerline, as shown in Figure 6-6.1-3. Slightly non-radial penetrations are aligned parallel to the horizontal or vertical centerline of the suppression chamber segment and are slightly offset. Non-radial penetrations are aligned parallel to the suppression chamber vertical centerline, producing an oblique orientation with respect to the torus shell, as shown in Figure 6-6.1-4. COM-02-039-6 6-6.2 i Revision 0 I nutggh

O Typical penetration reinforcement modifications are shown in Figures 6-6.1-2 through 6-6.1-4. The modifications include pipe sections which are installed as sleeves to reinforce the penetration nozzles. Support arms extend radially from the pipe sleeves to pad plates attached to the suppression chamber shell. Each penetration modification is designed to allow the penetrations to sustain TAP reaction loads produced by suppression chamber motions due to normal loads and hydrodynamic loads while keeping component stress intensities below the allowable values specified in Reference 6. O i O COM-02-039-6 6-6.3 ~ Revision 0 nutggh

Table 6 -6.1-1 PENETRATION AND GEOMETRY REINFORCEMENT SCHEDULE EXTERNAL PENETRATION REINFORCEMENT PENETRATION DIAMETER REFERENCE FIGURE NUMBER (INCHES) SUPPORT ARMS X-203A 18 NO 6-6.1-1 X-204A, B, 20 YES 6-6.1-3 20 NO 6-6.1-1 X-205 X-210A, B 14 YES 6-6.1-4 X-211A, B 6.625 YES 6-6.1-4 X-212 8.625 YES 6-6.1-4 X-220 24 NO 6-6.1-1 X-221 2.375 NO 6-6.1-1 X-222 2.375 NO 6-6.1-1 O COM-02-039-6 Revision 0 6 -6. 4 l nutpsh o

O ( PIPE i CIRCUMFERENTIAL WELD (TYP) PENETRATION ' N NOZZLE SUPPRESSION INSERT PLATE O I CIRCUMFERENTIAL WELD (TYP) i Figure 6-6.1-1 TYPICAL UNREINFORCED PENETRATION COM-0 2-0 39 -6 Revision 0 6-6.5 nutgg.h

O 1 1/4 TnICx PAD FMTE (TYP) / A,a '"Ea5!i'* ca snEx.z. s e i t enzcx extranAr. s p PIPE SLEEVE (TYP) l I i) l-q rEnEraArron br> ( t 1/4 Turex surront Anx trYe> ,,,,,,y,, I L A,a N l ~ l Figure 6-6.1-2 EXTERNAL VIEW OF TYPICAL PENETRATION REINFORCEMENT COM-02-039-6 Revision 0 6-6.6 nutggh

g PENETRATION NOZZLE = SUPPORT ARM SLEEVE (TYP) g (TYP) PAD PLATE l l o. l l v. = .a L. _ _ _. s ~~ ~ Z 2 7_ZZZ O I SECTION A-A Figure 6-6.1-3 REINFORCEMENT DETAILS FOR TYPICAL RADIAL PENETRATIONS O COM-02-039-6 Revision 0 6-6.7 nutggh

O SUPPORT ARM q PENETRATION NOZZLE PAD PLATE SLEEVE = s _] r_ l vt i I ..J l 1

~st_

N s[ t s svs 4 4 i SECTION B-B Figure 6-6.1-4 REINFORCEMENT DETAILS FOR TYPICAL NON-RADIAL PENETRATIONS COM-02-039-6 6-6.8 Revision 0 nutg_qh

6-6.2 Loads and Load Combinations The loads for which the Quad Cities Unit 1 suppression chamber penetrations are evaluated are defined in MUREG-0661 on a generic basis for all Mark I plants. The methodology used to develop plant unique torus attached piping reaction loads for each penetration is discussed in Section 6-2.0. The results of applying the controlling reaction loads which act on the penetrations are discussed in Section 6-6.2.1. Using the event combinations and event sequencing defined in NUREG-0661 and discussed in Volume 1, the governing load combinations which affect the penetra-tions are formulated. The load combinations are discussed and presented in Section 6-6.2.2. i l l t I COM-02-039-6 6-6.9 Revision 0

6-6.2.1 Loads The loads acting on the suppression chamber penetrations are categorized as follows: 1. Dead weight Loads 2. Seismic Loads 3. Pressure and Temperature Loads 4. Operating Loads 5. Static Torus Displacement Loads 6. Safety Relief Valve Discharge Loads j 7. Vent Clearing Loads 8. Pool Swell Loads 9. Condensation Oscillation Loads 10. Chugging !.oads 11. Torus Motion Loads Loads in the above categories include those acting on torus attached piping discussed in Section 6-2.2.1 and those acting on the torus shell discussed in Volume 2. l Loads acting directly on torus attached piping systems result in reaction loads on the penetrations. Loads l acting directly on the torus shell result in suppres-sion chamber motions. The suppression chamber motions excite the attached piping systems and produce reaction loads on the penetrations. In addition, loads acting COM-02-039-6 6-6.10 Revision 0 nutgsb

] directly on the torus shell produce initial stresses in the shell and insert plate, which are included in the evaluation as discussed in Section 6-6.4. i The reaction loads used in the suppression chamber penetration evaluation for each load category are taken from the TAP system evaluation presented in Sections 6-2.4 and 6-2.5. The components of these reaction loads at the penetrations consist of the maximum forces and moments acting on the penetration nozzle both inside and outside the suppression chamber. The reaction loads include the coupling effects of the TAP system and the suppression chamber as discussed in Section 6-2.4. m (v\\ Maximum torus operating temperature and pressure values are used in the analysis cf the penetrations listed in Table 6-6.2-1. These values are taken from Reference 3 and envelop the maximum operating pressures and temperatures. COM-02-039-6 6-6.11 ' Revision 0 nutggb

6-6.2.2 Load Combinations The loads for which the suppression chamber penetra-tions are evaluated are presented in Section 6-6.2.1. The general NUREG-0661 criteria for grouping the loads into load combinations are discussed in Volume 1. Not all load combinations for each event need to be

examined, since many are enveloped by others which contain the same or additional loads.

Table 6-6.2-1 shows the governing load combinations used in evaluating the suppression chamber penetrations. O l l l l l COM-02-039-6 6-6.12 Revision 0 nutggb

Table 6-6.2-1 GOVERNING PENETRATION LOAD COMBINATIONS AND SERVICE LEVELS COMBINATION LOAD COMBINATIONS (l) ERV CE NUMBER lDW + TE1 + THAM 1 + TD(3) + OLl+ ( l QAB l + l CHUG l + l QABIl + lOBElI4) CHUG-14E + l CHUGIl) or 2 ( l QAB l + 8 CHUG l + B l QABI l + l OBE l(4) + l CHUGIl), WHICHEVER IS HIGHER lDW + TE1 + THAM 1 + TD(3) + OLl CHUG-14M + l QAB l + l QABIl + l OBE l54I+ l CHUG l B + l CHUG l I lDW + TE1 + THAM 1 + TD(3) + OLl CHUG-27M + l QAB l + l SSE l(5) + lQABIl+ C l CHUG l + l CHUG l I lDW + TE1 + THAM 1 + TD(3) + OLl PS-15M + l QAB l + l SSE l(5) +.l QABIl + l PSl C + l PS l I lDW + TE1 + THAM 1 + TD(3) + oLj PS-18M(2) B + l OBEl(4) + l PS l + l PSI l lDW + TE1 + THAM 1 + TD(3) + oLl CO-27M C + l SSE l(5) + l COl + l COIl (1) SEE SECTION 6-2.2.1 FOR DEFINITION OF SYMBOLS USED IN LOAD COMBINATION. (2) PRIMARY PLUS SECONDARY STRESS INTENSITY RANGE AND FATIGUE EVALUATION ARE NOT REQUIPED, SINCE CHUG-14E GOVERNS. (3) TD IS THE MAXIMUM OF TD, TD AND TD. y 2, 3 (4) OBE IS DEFINED AS OBE7 + OBED* (5) SSE IS DEFINED AS SSE7 + SSED* l' COM-02-039-6 Revision 0 6-6.13 nut.e_qh 'E. J

6-6.3 Acceptance Criteria The acceptance criteria defined in NUREG-0661 are the basis for the Quad Cities Unit 1 suppression chamber penetrations analysis. These criteria are discussed in volume 1. In general, the acceptance criteria follow the rules contained in the ASME Code, Section III, Division 1, 1977 Edition up to and including the 1977 Summer Addenda (Reference 6). The corresponding service level limits and allowable stresses are also consistent with the requirements of the ASME Code and NUREG-0661. The suppression chamber penetrations and reinforcing modifications are evaluated in accordance with the requirements for Class MC components contained in the ASME Code. The jurisdictional boundaries for the penetration MC components are defined at the inner and outer piping / nozzle circumferential welds nearest to the suppression chamber. l t O l COM-02-039-6 6-6.14 Revision 0 nutggh W

4 4 6-6.4 Methods of Analysis s The methodology ur-od to evaluate the penetrations for the loading conditions described in Section 6-6.2.1 is discussed in the following paragraphs. All of the large bore suppression chamber penetrations listed in Table 6-6.1-1 have been evaluated using finite element models. i 't Based on similarities in geometric configurations of selected. penetrations discussed in Section 6-6.1, six analytical models are used to represent a total of twelve penetrations. The mechanical and thermal loads t for each group of penetrations are enveloped and applied to the associated analytical model. The allowable stresses for the representative penetrations are determined at the maximum temperature, as discussed in Section 6-6.2. 4 The finite element models of the penetrations consist of the external and internal nozzles, the insert plate, a portion of the suppression chamber shell, and for the reinforced penetrations, the support arms, the pad . plates, and the nozzle sleeves. Thin plate finite l . elements ~are used to model each component explicitly. 1 I d COM-02-039-6 6-6.15 Revision 0 l'

l Figure 6-6.4-1 shows a typical penetration analytical model. The entire length of each nozzle is modeled between the inner and outer piping / nozzle circumferential welds nearest to the suppression chamber shell. The portion of the suppression chamber shell included in the models is chosen to minimize the impact of boundary effects on the region of stress evaluation. Translational restraints are imposed at the boundary l nodes on the so pression chamber shell section of the models. Where pad plates are attached to the suppression

chamber, shell element thicknesses are taken as the effective thickness of the suppression chamber shell and the pad plate.

The maximum absolute value of each force and moment component for each reaction load case is conservatively l applied to the analytical models in a manner which l l l maximizes penetration stresses. Local thermal effects at each penetration are also evaluated. The stresses in the suppression chamber shell and insert plate due to piping reactions are added to the stresses in the suppression chamber shell due to loads COM-02-039-6 6-6.16 Revision 0 nutgqh

r [ acting directly on the suppression chamber. These \\ stresses are taken from the suppression chamber analysis results discussed in Volume 2. The stress intensities of the dynamic loads are combined using direct summation in accordance with Reference 8. The maximum stress intensities for each penetration component are calculated and compared to stress i allowables. The small bore piping penetrations are evaluated in a manner similar to the above described procedure. For these penetrations, however, a computer code based on closed-form solutions for nozzle-type attachments ' to cylindrical vessels is used. The mechanical and thermal loads from the piping analysis are applied to the nozzles. The maximum stress intensities for each penetration component are then calculated and compared to the allowable stresses. Fatigue effects for the penetration with the highest stress levels and maximum loading cycles are evaluated. The number of stress cycles and load cycles for each loading case is established using the suppression chamber analysis results presented in Reference 10. i l The alternating stress intensity for each loading is a COM-02-039-6 6-6.17 L Revision 0

then calculated. Fatigue strength reduction factors of 2.0 for major component stresses and 4.0 for component weld strasses are conservatively used. The governing cumulative fatigue usage factor is determined by calculating fatigue usage for the controlling event combination. l i i O l COM-02-039-6 6-6.18 Revision 0 nutech

%) { l 8 C 5e d W c o ,4 9 d I a E \\ s a 5 ~ (D ~ s" s i .T w E m l A 4 8 iu zO E G C 8 v3 I l l l lO COM-02-039-6 Revision 0 6-6.19 nutagh

6-6.5 Analysis Results The geometry, loads and load combinations, acceptance criteria, and analysis methods used in the evaluation of the Quad Cities Unit 1 suppression chamber penetra-tions are presented and discussed in the previous sections. The results from the evaluation of the penetrations are presented in Tables 6-6.5-1 through 6-6.5-6. These tables show the maximum calculated stresses and the associated design margins for the major penetration components for the governing load combinations. The unreinforced SBP penetrations were also evaluated and found to be within the specified allowable limits. The cumulative fatigue usage factors for the controlling component and weld are within the acceptable fatigue usage factor of 1.0. i l COM-02-039-6 6-6.20 Revision 0 nutggh

Table 6-6.5-1 PENETRATION EVALUATION STRESS

SUMMARY

FOR PENETRATION X-203 LOAD CASE CHUG-14E CHUG-14M PS-15M STRESS INTENSITY COMPONENT MAXIMUM' LIMIT MAXIMUM LIMIT MAXIMUM LIMIT (ksi) (ksi) (ksi) (ksi) (ksi) (ksi) TORUS 48.60 69.50 21.00 28.95 23.80 53.80 INSERT PLATE 32.60 69.50 18.08 28.95 20.01 53.80 PAD N/A N/A N/A N/A N/A N/A STIFFENER N/A N/A N/A N/A N/A N/A NOZZLE 23.30 54.90 5.71 22,65 7.03 42.45 O COM-02-039-6 Revj-ion 0 6-6.21 nutech

Table 6-6.5-2 PENETRATION EVALUATION STRESS

SUMMARY

FOR PENETRATION X-204 LOAD CASE CHUG-14E CHUG-14M PS-15M ^ STRESS INTENSITY COMPONENT MAXIMUM LIMIT MAXIMUM LIMIT MAXIMUM LIMIT (ksi) (ksi) (ksi) (ksi) (ksi) (ksi) TORUS 43.90 69.50 16.90 28.95 21.70 53.80 INSERT PLATE 42.20 69.50 18.00 28.95 25.60 53.80 PAD 45.10 69.50 15.50 28.95 19.20 53.80 STIFFENER 24.90 69.50 17.70 28.95 30.90 53.80 NOZZLE 50.30 69.50 12.20 28.95 23.00 53.80 6 l 1 COM-02-039~6 Revision 0 6-6.22 nutggb

Table 6-6.5-3 PENETRATION EVALUATION STRESS

SUMMARY

FOR PENETRATION X-205 i LOAD CASE CHUG-14E l CHUG-14M PS-15M STRESS INTENSITY COMPONENT MAXIMUM LIMIT MAXIMUM LIMIT MAXIMUM LIMIT (ksi) (ksi) (ksi) (ksi) (ksi) (ksi) TORUS 33.67 69.50 16.36 28.95 27.90 53.80 INSERT PLATE 27.21 69.50 15.61 28.95 27.93 53.80 PAD N/A N/A N/A N/A N/A N/A l STIFFENER N/A N/A N/A N/A N/A N/A NOZZLE 17.79 54.90 4.81 22.65 6.69 42.45 s s i O COM-02-039-6 Revision 0 6-6.23 nutggb

Table 6-6.5-4 PENETRATION EVALUATION STRESS

SUMMARY

FOR PENETRATION X-210 LOAD CASE CHUG-14E CHUG-14M PS-ISM CONTAINMENT / STRESS INTENSITY COMPONENT MAXIMUM LIMIT MAXIMUM LIMIT MAXIMUM LIMIT (ksi) (ksi) (ksi) (ksi) (ksi) (ksi) TORUS 37.60 69.50 17.80 28.95 19.50 53.80 INSERT PLATE 36.76 69.50 25.56 28.95 28.58 53.80 PAD 41.25 69.50 14.39 28.95 15.94 53.80 STIFFENER 17.52 69.50 9.23 28.95 12.02 53.80 i NOZZLE 28.47 54.90 13.06 22.65 16.92 42.45 e l l l l l COM-02-039-6 Revision 0 6-6.24 nutggh

Table 6-6.5-5 PENETRATION EVALUATION STRESS

SUMMARY

FOR PENETRATION X-211 LOAD CASE CHUG-14E CHUG-14M PS-ISM 4 O" ^ COMPONENT STRESS INTENSITY I MAXIMUM LIMIT MAXIMUM LIMIT MAXIMUM LIMIT (ksi) (ksi) (ksi) (ksi) (ksi) (ksi) TORUS 26.40 69.50 13.20 28.95 14.50 53.80 INSERT PLATE 26.80 69.50 12.70 28.95 18.20 53.80 PAD 22.50 69.50 15.10 28.95 14.00 53.80 STIFFENER 8.30 69.50 6.10 28,95 9.00 53.80 NOZZLE 20.40 54.90 10.10 22.65 15.20 42.45 O t l ( t I I( COM-02-039-6 Revision 0 6-6.25 nutggb - _.. _ ~ _ _ _ _ _

Table 6-6.5-6 PENETRATION EVALUATION STRESS

SUMMARY

FOR PENETRATION X-220 LOAD CASE CHUG-14E CHUG-14M PS-ISM CONTAINMENT / STRESS INTENSITY COMPONENT MAXIMUM LIMIT MAXIMUM LIMIT MAXIMUM LIMIT (ksi) (ksi) (ksi) (ksi) (ksi) (ksi) TORUS 33.58 69.50 18.08 28.95 20.18 53.80 INSERT PLATE 19.58 69.50 17.08 28.95 18.08 53.80 PAD 17.30 69.50 2.50 28.95 4.20 53.80 STIFFENER 4.30 69.50 3.30 28.95 5.70 53.80 NOZZ LE 23.60 54.90 14.30 22.65 22.40 42.45 O COM-02-039-6 Revision 0 6-6.26 nutggh

_ _ = p 6-7.0 LIST OF REFERENCES i V 1. " Mark I Containment Long-Term Program," Safety Evaluation Report, USNRC, NUREG-0661, July 1980; Supplement 1, August 1982. 2. " Mark I Containment Program Load Definition Report," General Electric

Company, NEDO-21888, Revision 2,

November 1981;

Addenda, Sheet 1,

April 1982. 3. " Mark I Containment Program Plant Unique Load Definition," Quad Cities Station, Units 1 and 2, General Electric Company, NEDO-24567, Revision 2, April 1982. 4. " Safety Analysis Report," Quad Cities Station, Units 1 and 2, Commonwealth Edison

Company, Section 3.9, July 20, 1982.

5. " Mark I Containment Program Structural Acceptance Criteria Plant Unique Analysis Applications Guide," Task Number 3.1.3, Mark I Owners Group, General Electric Company, NEDO-24583-1, October 1979. ' [N} 6. ASME Boiler and Pressure Vessel Code, Section III, \\s j Division 1, 1977 Edition with Addenda up to and l including Summer 1977. 7. " Mark I Containment Program Augmented Class 2/3 Fatigue Evaluation Method and Results for Typical Torus Attached and SRV Piping Systems," MPR Associates, Inc., MPR-751, November 1982. 8. " Methodology for Combining Dynamic Responses," i USNRC, NUREG-0484, Revision 1, May 1980. 9. Letter from D. B. Vassallo (NRC) to H. C. Pfefferlen (GE), " Acceptability of SRSS Method for Combining Dynamic Responses in Mark I Piping Systems," dated March 10, 1983. 10. " Combining Modal Responses and Spatial Components in Seismic Response Analysis," USNRC, Regulatory Guide 1.92, Revision 1, February 1976. l l 11. " Pipe Support Base Plate Designs Using Concrete Expansion Anchor Bolts," NRC Office of Inspection and Enforcement, IEB-79-02, Revision 2, November 8, 1979. p COM-02-039-6 6-7.1 Revision 0

l 12.

Wichman, K.

R., Hopper, A. G., and Mershon, J. L., " Local Stresses in Spherical and Cylindrical Shells due to External Loadings," Wolding Research Council Bulletin 107, March 1979. 13. " Code Requirements for Nuclear Safety Related Concrete Structures," American Concrete Institute, ACI 349-80, 1980. 14. " Procedure for Evaluation of the De sig n of Rectangular Cross Section Attachments on Class 2 or 3 Piping," ASME Code Case N-318, Section III, Division 1, July 13, 1981. O COM-02-039-6 6-7.2 Revision 0 nutggh -}}