Text

._

COM-02-039-4

/N Revision 0

-(

)

May 1983 64.305.2103 QUAD CITIES NUCLEAR POWER STATION UNITS 1 AND 2 PLANT UNIQUE ANALYSIS REPORT VOLUME 4 INTERNAL STRUCTURES ANALYSIS Prepared for:

Commonwealth Edison Company

N Prepared by:

s-NUTECH Engineers, Inc.

San Jose, California Approved by:

AVV k

D. O. Talbott I.

D.

McInnes, P. E.

Project Leader Engineering Manager h

R.

H.

Adams, P.E.

Engineering Director Issued by:

LLC

/N, A. K. Moonka, P.E.

R.

H.

Buchholz (b)

Project Manager Project Director

).

8307180158 830627 n

E8 PDR ADOCK 05000237 P

PDR

REVISION CONTROL SHEET

,O Quad Cities Nuclear Power Station, REPORT NUMBER: COM-02-039-4 V)LE l

Units 1 and 2 Revision 0 Plant Unique Analysis Report Volume 4 i

I.

D. McInnes/ Engineering Manager IM INITIALS D.

C. Talbott/ Consultant I

((

INITIALS M.

D.

Pratt/ Engineering Analyst 7[ITIALS R. Fernandez/ Consultant II h

INITIALS C.

T.

Shyy/ Senior Engineer DIE INITIALS

'N

(

/

'O INITIAL 5 INITIALS I.PAGE(S)

C-

~

PRE-ACCURACY CRITERIA gg REV A

I

^

A ED CHECK CHECK PARED CHECK CHECK PAGE (S )

g ID 4-1i{

A7 N/A 4-3.1 0

0 l

4-1.1-g7 IM 4-1.5 l

l

15 M

F l

4-2.16 f8([

W 4-2.17

((

6G j

'I#

Ib 4-2.18 M

I

-d-2.19 0 AT M

lh 0

-2.9n QEP-001.4-00 4-ii l

nutggh

ABSTRACT 4

The primary containments for the Quad Cities Nuclear Power j

Station Units 1 and 2 were designed, erected, pressure-tested, and N-stamped in accordance with the ASME Boiler and Pressure Vessel Code,Section III, 1965 Edition with addenda up to and including Summer 1965 for the Commonwealth Edison Company (CECO) by the Chicago Bridge and Iron Company.

Since

then, new requirements have been established.

These requirements affect the design and operation of the primary containment system and are defined in the Nuclear Regulatory Commission's (NRC) Safety Evaluation

Report, NUREG-0661.

This report provides an assessment of containment design loads postulated to occur during a

loss-of-coolant accident or a safety relief valve discharge event.

In addition, it provides an assessment of the effects that the postulated events have on containment systems 4

operation.

This plant unique analysis report (PUAR) documents the efforts h

undertaken to address and resolve each of the applicable NUREG-0661 requirements.

It demonstrates that the design of the primary containment system is adequate and that original design safety margins have been restored, in accordance with NUREG-0661 acceptance criteria.

The Quad Cities Units 1 and 2 PUAR is composed of the following seven volumes:

o Volume 1 - GENERAL CRITERIA AND LOADS METHODOLOGY o

Volume 2 - SUPPRESSION CHAMBER ANALYSIS o

Volume 3 - VENT SYSTEM ANALYSIS o

Volume 4 - INTERNAL STRUCTURES ANALYSIS o

Volume 5 - SAFETY RELIEF VALVE DISCHARGE LINE PIPING ANALYSIS p) i COM-02-039-4 Revision 0 4-iii nutggb

~ --_

I o

Volume 6 - TORUS ATTACHED PIPING AND SUPPRESSION h

CHAMBER PENETRATION ANALYSES (OUAD L

CITIES UNIT 1) o Volume 7 - TORUS ATTACHED PIPING AND SUPPRESSION CHAMBER PENETRATION ANALYSES (QUAD

-CITIES UNIT 2)

This volubte documents the evaluation of the suppression chamber internal structures.

Volumes 1 through 4 and 6 and 7 have been prepared by NUTECH Engineers, Incorporated (NUTECH), acting as an agent to the Commonwealth Edison Company.

Volume 5 has been prepared by Sargent and Lundy, who performed the safety relief valve discharge line (SRVDL) piping analysis.

Volume 5

describes the methodology and procedures used in the SRVDL piping analysis.

4 i

4 l

1 4

I i

i f

l COM-02-039-4 l

Revision 0 4-iv M

TABLE OF CONTENTS Page ABSTRACT 4-lii LIST OF ACRONYMS 4-vi LIST OF TABLES 4-vii LIST OF FIGURES 4-vili 4-

1.0 INTRODUCTION

4-1.1 4-1.1 Scope of Analysis 4-1.2 4-1.2 Summary and Conclusions 4-1.4

'4-2.0 INTERNAL STRUCTURES ANALYSIS 4-2.1 4-2.1 Component Description 4-2.2 4-2.1.1 Catwalk 4-2.3 4-2.1.2 Electrical Conduits 4-2.8 1

4-2.2 Loads and Load Combinations 4-2.9 4-2.2.1 Loads 4-2.10 4-2.2.2 Load Combinations 4-2.13 4-2.3 Acceptance Criteria 4-2.15 4-2.4 Methods of Analysis 4-2.16 4-2.5 Analysis Results 4-2,17 P

4-2.5.1 Closure 4-2.20 4-3.0 LIST OF REFERENCES 4-3.1 l

-~

,j COM-02-039-4 Revision 0 4-v L

nutggb

h LIST OP' ACRONYMS ASME American Society of Mechanical Engineers CO Condensation oscillation DBA Design Basis Accident ECCS Emergency Core Cooling System l

IBA Intermediate Break Accident IR Inside Radius LDR Load Definition Report LOCA Loss-of-Coolant Accident NRC Nuclear Regulatory Commission NVB Non-Vent Bay OBE Operating Basis Earthquake i

PUAAG Plant Unique Analysis Applications Guide PUAR Plant Unique Analysis Report PULD Plant Unique Load Definition SRV Safety Relief Valve SSE Safe Shutdown Earthquake O

VB Vent Line Bay 4

COM-02-039-4

'(

Revision 0 4-vi

.-. - = -..-. -

1 F

r 5

i j

LIST OF TABLES r

4 Number Title Page i

t 4-2.2-1 Internal Structures Component Loading 4-2.12 i

Identification 4-2.2-2 Internal Structures Controlling Load 4-2.14 Combinations i

4-2.5-1 Catwalk Stresses for Controlling Load 4-2.18 Combinations 4-2.5-2 Maximum Suppression Chamber Shell 4-2.19 Stresses at Catwalk Reinforcement Beam l

Locations i

(

l r

i l

i t

i l

i l

i

(

l l

l-COM-02-039 '

Revision 0 4-vil

LIST OF FIGURES i

. Number Title Page 4-2.1-1 Plan View of Suppression Chamber Internal 4-2.5 Catwalk 4-2.1-2 Suppression Chamber Internal Catwalk-Typical Support at Miter Joint 4-2.6 I

4-2.1-3 Suppression Chamber Internal Catwalk-Typical Support Between Miter Joints 4-2.7 i

d j

E a

1 l

P i

i 4

4 4-i COM-02-039-4

_ Revision 0 4-viii

4-

1.0 INTRODUCTION

In conjunction with volume 1

of the Plant Unique Analysis Report (PUAR),

this volume documents the efforts undertaken to address the requirements defined in NUREG-0661 (Reference 1) which affect the Ouad Cities Units 1 and 2 internal structures.

The internal structures PUAR is organized as follows:

o INTRODUCTION Scope of Analysis Summary and Conclusions o

INTERNAL STRUCTURES ANALYSIS (Catwalk and Electrical Conduits)

Component Description Loads and Load Combinations Acceptance Criteria Methods of Analysis Analysis Results The INTRODUCTION section contains a general overview 1 discussion of the internal structures evaluation.

The INTERNAL STRUCTURES ANALYSIS section discusses the specific components, loads,- criteria,

methods, and

~

L results associated with the evaluation.

'\\--

COM-02-039-4 l

Revision 0 4-1.1

4-1.1 Scope of Analysis O

The criteria presented in Volume 1 are used as the basis for all of the Quad Cities Units 1 and 2 internal structures evaluations described in this volume.

The internal structures evaluated are the catwalk and electrical conduits.

These structures are not required for the safe operation of the primary containment system during accident conditions.

These internal structures are evaluated for the effects of loss-of-coolant accident (LOCA) and safety relief valve (SRV) discharge-related loads, as defined by the Nuclear Regulatory Commission's (NRC) Safety Evbluation Report, NUREG-0661, and the " Mark I Containment Program Load Definition Report" (LDR) (Reference 2).

The LOCA and SRV discharge loads used in this evalua-tion are formulated using the procedures discussed in Volume 1 of this report.

The evaluation includes a structural analysis of the internal structures to ensure that these structures do not fail and result in damage to safety-related components.

l l

COM-02-039-4 Revision 0 4-1.2 nutggh

i The results of the structural evaluation for each load are used to evaluate load combinations for the internal structures in accordance with the " Mark I Containment Program Plant Unique Analysis Application Guide" (PUAAG)

(Reference 3).

The evaluation results are conservatively compared with the -acceptance limits specified by the applicable sections of the American Society of Mechanical Engineers (ASME) Code (Reference 4) to ensure that safety-related components are not adversely affected.

i Other internal structures evaluated were the vent line

drain, thermowells, and the emergency core cooling system (ECCS) suction strainers.

They are described in Sections 2 -2.1, 3 -2.1, 6-2.1, and 7-2.1, respectively, i

4 l

COM-02-039-4 Revision 0 4-1.3

4-1.2 Summary and Conclusions O

The evaluation documented in this volume is performed for the Quad Cities Units 1 and 2 internal structures identified in Section 1-1.1 and described in Section 1-2.1.

These structures are the catwalk and electrical conduits.

The LOCA and SRV discharge-related events defined in NUREG-0661 result in hydrodynamic loadings on the internal structures.

The major loadings which affect the catwalk and ele 6trical conduits above the suppression pool include pool swell impact and drag

loads, froth impingement
loads, and pool fallback loads.

The major loadings which affect submerged portions of the catwalk include submerged structure loadings.

Conservative values for these loadings are developed using the methodology discussed in Section 1-4.0.

Other loads such as dead weight and seismic loads have a lesser effect on the internal structures, l

but are also considered in the evaluation.

l l

l l

l l

l l

l l

l COM-02-039-4 Revision 0 4-1.4 nute_cb

.. -.. ~ -.

=

fv The analysis results for these loadings are used to b

V formulate the controlling event combinations which affect the internal structures, as discussed in Section 1-3.2.

The results are compared to acceptance limits i

which ensure that the internal ' structures do not fail and result in damage to safety-related components. The l

evaluation results show that the stresses for all of I

the internal structures are within acceptable limits.

The NUREG-0661 requirements are therefore considered to be met.

i i

i i

4 1

i I

4 1

1 i

i

.COM-02-039-4 Revision 0 4-1.5

. -. _.. ~ _....... _,. -. _ _..

INTERNAL STRUCTURES ANALYSIS O

4-2.0 An evaluation of each of the NUREG-0661 requirements which affect the design adequacy of the Quad Cities Units 1 and 2 internal stru'ctures is presented in the following sections.

The criteria used in the evaluation are contained in Volume 1 of this report.

The internal structures components which are examined are described in Section 4-2.1.

The loads and load combinations which are evaluated are described and i

presented in Section 4-2.2.

The acceptance limits to I

which the analysis results are compared are discussed and presented - in Section 4-2.3.

The analysis method-ology used to evaluate the effects of these loads and load combinations is discussed in Section 4-2.4.

The analysis results and the corresponding design margins are presented in Section 4-2.5.

~

j l

I i

O

-COM-02-039-4 l

v Revision 0 4-2.1

l l

l l

l 4-2.1 Component Description O

The internal structures which are evaluated include the catwalk and electrical conduits, which are described in Sections 4-2.1.1 and 4-2.1.2, respectively.

I i

l

[

i O

l l

COM-02-039-4 l

Revision 0 4-2.2 nutggb

fG 4-2.1.1 Catwalk

).

The catwalk is a platform-type structure approximately three feet

wide, which extends around the full The 'atwalk circumference of the suppression chamber.

c is located in the upper outside quadrant of each suppression chamber mitered cylinder.

The catwalk frame consists of two C9 x 13.4 stringers, which extend from ring girder to ring girder.

The catwalk frame is supported at two intermediate locations between ring girders in the non-vent line bays (NVB) and at one intermediate location in the vent O

line bays (VB) (Figure 4-2.1-1).

The supports at the g,

ring girders consist of a W12 x 136 horizontal support beam attached to a 6" XXS vertical pipe column (Figure 4-2.1-2).

The intermediate supports consist of a

W16 x 36 horizontal support beam attached to a 4",

Schedule

120, vertical pipe strut.

The pipe strut connects to a reinforcement beam which distributes the pipe strut forces to the suppre'ssion chamber shell (Figure 4-2.1-3).

l The catwalk platform consists of grating that spans the l

stringers.

The grating is attached to the stringers by

ON -

COM-02-039-4 Revision'O 4-2.3

intermittent welds.

Additional hold-down support is provided by L3 x 2 x 3/8 hold-down angles that are bolted to the stringers.

The catwalk stringers are braced against lateral loads by:

L3 x 3x 1/4 angles placed between stringer pairs, the same size angles placed between the stringers and the ring girder, and the horizontal support members at the ring girders (Figure 4-2.1-1).

O l

1 l

l l

COM-02-039-4 Revision 0 4-2.4 nutggb

O INTERMEDIATE j

/

SUPPCRT C9 x 13.4 s

i STRINGER SUPPRESSION

/

'(

T LINE ER

'=====

l l

\\

e#

[qMITERJCINT A

%s== \\1

^#

bh5 QN 5 EIIO OIEEEI k- _ _I.__

N 5

8

( NON-VENT INTE3MEDIATgd l

I.INE SAY SUPPCRTS 3'-11 1 /2" O-(TYP)

W.

i

... S. m.,

CF CONTAINMENT GRATINGd

\\

-f

\\

.' $ '~

l

\\

l t

1.

SEE FIGURE 4-2.1-2 FOR SECTION A-A.

2.

SEE FIGURE 4-2.1-3 FOR SECTION B-B.

Figure 4-2.1-1 PLAN VIEW OF SUPPRESSION CHAMBER l

INTERNAL CATWALK COM-02-039-4 Revision 0 4-2.5 nutggb

C CATWALK q SUPPRESSION j

CHAMBER I

3 X 2 X 3/8 gggg7g GRATING HOLD DCWN ANGLES o

i C9 x 13.4 STRINGERS 3/4" THICK PLATE l

{

y W12 x 136 c,

i l

-t O

RING GIRDER 6" DIA PIPE 1" THICK PLATE SUPPRESSION CHAMBER SHELL 13'-2 1/2" IR 1

15'-0" 1R SECTION A-A (FROM FIGURE 4-2.1-1)

Figure 4-2.1-2 SUPPRESSION CHAMBER INTERNAL CATWALK -

TYPICAL SUPPORT AT MITER JOINT COM-02-039-4 l

Revision 0 4-2.6 nutggh

l O't q SUPPRESSION CHAMBER g

S4'-6" TO q CT CONTAINMENT SUPPRESSION CHAMBER SHELL 15'-0" REINFORCEMENT IR BEAM

( CATWALK 8'-4 7/16" VENT LINE BAY t l

=':

8'-6"

~

NON-VENT LINE BAY, i

HANDRAIL i

4" DIA C9 X 13.4 PIPE l

J STRINGER g

a' l

'l W16 X 36 s

j, 4

-Q l

10'-10" SECTION B-B (FROM FIGURE 4-2.1-1)

Figure 4-2.1-3 SUPPRESSION CHAMBER INTERNAL CATWALK -

TYPICAL SUPPORT BETWEEN MITER JOINTS

'COM-02-039-4 Revision 0 4-2.7

4-2.1.2 Electrical Conduits e

The vacuum breaker conduits provide power and circuitry for solenoids and instrumentation located on the drywell/wetwell vacuum breakers.

The instrumentation is used to monitor the valve open and closed positions during start-up testing.

The wiring for the vacuum breaker electrical system is routed inside 2"

and 3"

diameter rigid steel conduit from two suppression chamber penetration locations to each vacuum breaker.

The conduits are attached to horizontal members attached to the bottom of the catwalk stringers and to short, vertical membere that are welded to the web of the catwalk stringers.

Junction boxes at the connection and termination points of the conduit are also supported on

short, vertical members that are welded to the web of the stringers.

COM-02-039-4 Revision 0 4-2.8 nutggb 1

---_-__-_-____--______________u

4 1 -

(

4-2.2 Loads and Load Combinations j

The loads for which the Ouad Cities Units 1 and 2 internal structures are evaluated are defined in NUREG-0661 on a generic basis for all Mark I plants.

The methodology used to develop plant unique loads for r

each applicable load defined in NUREG-0661 is discussed in Section 1-4.0.

The results of applying the i

methodology to develop specific values for each of the y

j controlling loads are discussed and presented in i

Section 4-2.2.1.

1 1

i The controlling load combinations which affect the i

internal structures are formulated by usincj the event combinations and event sequencing defined in NUREG-0661 and discussed in Sections 1-3.2 and 1-4.3.

The controlling load combinations are discussed and 1

. presented in Section 4-2.2.2.

i i

i i

(

i l

lCOM-02-039-4 Revision 0-4-2.9

,an,,v----

,n,

+m,

.n,-,,,n

.-.-ev,e-,cea,-,.

,,,,,-m--

,,,--,ver--nm-

4-2.2.1 Loads O

The loads acting on the internal structures are categorized as follows:

1.

Dead Weight Loads a.

Dead Weight of Steel 2.

Seismic Loads a.

Operating Basis Earthquake (OBE) b.

Safe Shutdown Earthquake (SSE) 3.

Pool Swell Loads a.

Pool Swell Impact and Drag b.

Froth Impingement and Fallback c.

Pool Fallback d.

LOCA Bubole-Induced Drag on Submerged Structures 4.

Condensation Oscillation (CO) Loads a.

Design Basis Accident (DBA)

CO Drag on Submerged Structures b.

Intermediate Break Accident (IBA) CO Drag on Submerged Structures 5.

Chugging Loads a.

Pre-Chug Drag on Submerged Structures b.

Post-Chug Drag on Submerged Structures COM-02-039-4 Revision 0 4-2.10 nutggb

6.

Safety Relief Valve Discharge Loads i

a.

SRV Discharge Bubble-Induced Drag on Submerged Structures j

7.

Containment Interaction Loads a.

Suppression Chamber Motions Table 4-2.2-1 shows the specific loads that affect the catwalk an6 conduit.

The methodology used to develop values for each of these. loadings is discussed in Section 1-4.0.

The resulting magnitudes and characteristics of each loading are similar to those described in Volumes 2 and 3 of this report.

i i

t I

i 4

4 4

l l

l

(

COM-02-039-4 l, t Revision.0 4-2.I1 I

M e--*-Ju-N em-

=

49-9m e

e e

p a-ge*1 e

w-g-mw-w w

-F

-t--*

grsqT ww-'Te

'- v &y m er--ap r-w'-*gw**-

    • mim eta,-mmwe--1 9-ywweMe--

q p

wFrr+a

-e-$

-y,W---777$

Table 4-2.2-1 INTERNAL STRUCTURES COMPONENT LOADING IDENTIFICATION VOLUME 4 LOAD DESIGNATION PUAR VOLUME ELECTRICAL SECTION CATWALK CONDUITS REFERENCE CATEG'ORY N MBER DEAD WEIGHT la X

X 1-3.1 2a X

X l-3.1 SEISMIC 2b X

X l-3.1 3a X

X l-4.1.4.2 3b X

l-4.1.4.3 POOL SWELL LOADS 3c X

X l-4.1.4.4 3d X (1) 1-4.1.6 4a X(1) 1-4.1.7.3 CONDENSATION OSCILLATION 4b X (1) 1-4.1.7.3 Sa X(1) 1-4.1.8.3 CHUGGING Sb X (1) 1-4.1.8.3 6a X W 1-4.2.4 DISCH RGE CONTAINMENT 7a X

VOLUME 2 INTERACTION (1)

APPLIES TO SUPPORT COLUMN AT THE RING GIRDER ONLY.

O COM-02-039-4 Revision 0 4-2.12 nutggh

A 4-2.2.2 Load Combinations The loadings which affect each of the internal struc-tures are presented in Section 4-2.2.1.

The general NUREG-0661 criteria for grouping these loads into event combinations are discussed in Section 1-3.2.

Since the electrical conduits and a majority of the internal catwalk components are located above or below the suppression pool, the event combinations which produce controlling stresses are those which contain pool swell and SRV discharge loads.

The submerged portions of the catwalk supports are s

subjected to LOCA air

clearing, condensation oscillation,
chugging, and SRV discharge submerged structure loads identified in Section 1-4.0.

The catwalk is evaluated for two controlling combinations.

These are the IBA 15 and the DBA 25 combinations as described in the PUAAG (Table 4-2.2-2).

The electrical conduits and junction boxes are evaluated for the controlling DBA 25 combination, since the pool swell j

load is the dominant load on these components.

l l

COM-02-039-4 g

Revision 0 4-2.13

~

f Table 4-2.2-2 INTERNAL STRUCTURES CONTROLLING LOAD COMBINATIONS f

LOAD COMBINATION LOAD DESIGNATION ( }

15(2) 25(2)

DEAD WEIGHT 1

1 OPERATING BASIS EARTHQUAKE SEISMIC SAFE SHUTDOWN EARTHQUAKE 2b 2b POOL SWELL 3a-3d CONDENSATION OSCILLATION (3) 4b CHUGGING (3)

Sa-Sb SRV DISCHARGE (3) 6 6

CONTAINMENT INTERACTION 7

7 TORUS SERVICE LEVEL AT WHICH STRESSES ARE EVALUATED CATWALK AND ELECTRICAL E( )

E(

CONDUITS (1)

SEE PUAR SECTION 4-2.2.1.

(2)

SEE NUREG-0661.

(3)

SUBMERGED STRUCTURE LOADINGS ONLY AFFECT SUBMERGED PORTIONS OF CATWALK COLUMN SUPPORTS.

(4)

THE CONTROLLING LOAD COMBINATION FOR THE TORUS SHELL AT CATWALK ATTACHMENT LOCATIONS IS THE DBA 18 COMBINATION AS DESCRIBED IN REFERENCE 3.

(5)

THE CATWALK IS CONSERVATIVELY ANALYZED TO SERVICE LEVEL D LIMITS.

COM-02-039-4 Revision 0 4-2.14 nutggh

O 4-2.3 Acceptance Criteria U) 8 Table 4-2.2-2 shows the service level assignments for the internal structures and the suppression chamber shell at attachment points to internal structures.

The table shows that the catwalk and electrical conduits are designated as Service Level E components, and as such, are not required to meet ASME Code acceptance limits.

In order to employ a consistent set of design criteria which ensures that failure will not occur, the catwalk is conservatively evaluated for the Service Level D acceptance limits contained in the ASME Code.

The suppression chamber shell near attachment points to internal structures is evaluated in accordance with the requirements for Class MC components contained in the ASME Code.

The corresponding allowable stresses of the catwalk components for the controlling combination are i

presented in Section 4-2.5.

The electrical conduits are evaluated to ensure that they will not impeir the function of safety-related components.

t

)

v COM-02-039-4 Revision 0 4-2.15 1

i 4-2.4 Methods of Analysis O

The loadings for which the internal structures are evaluated are identified in section 4-2.2.1.

The analysis of the catwalk is performed using manual calculations.

An equivalent static analysis is per-formed for all catwalk loadings except for containment interaction and pool swell loads, for which transient analysis is performed.

The transient analysis of the catwalk is performed using a beam finite element model which includes the stringers, hangers, and associated catwalk components.

The reaction loads from the catwalk pipe strut to the suppression chamber are obtained from the bounding load combination for the attachment point.

The results from a unit load case on a

finite element model composed of plate elements, which represents a

90' section of the suppression chamber shell and the reinforcement beam, are factored by the reaction loads from the catwalk.

The resulting stresses in the suppression chamber shell are combined I

with the stresses obtained from the suppression chamber analysis to evaluate local stresses in the suppression chamber shell.

Volume 2 of this PUAR describes the suppression chamber analysis and the general state of stress in the suppression chamber shell.

O COM-02-039-4 Revision 0 4-2.16 nutgsb

+

a 4-2.5 Analysis Results The

geometry, loads, load combinations, acceptance criteria, and analysis methods used in the evaluation of the internal structures are presented in the preceding sections.

Table 4-2.5-1 shows the resulting maximum stresses for the catwalk for the controlling load combination.

This table shows that the calculated stresses for these components are less than the corresponding allowable stresses.

Table 4-2.5-2 shows I

the state of stress in the suppression chamber shell at the catwalk reinforcement beam locations.

i The results of the electrical conduit supports and junction boxes confirm that the conduits will not impair the functions of safety-related components.

l

!C

!\\

COM-02-039-4 Revision 0 4-2.17

Table 4-2.5-1 CATWALK STRESSES FOR CONTROLLING LOAD COMBINATIONS l

LOAD COMBINATION STRESSES (ksi)

MATERIAL BEAM DBA 25 ITEM MATERIAL PROPERTIES STRESS OALCULATED(

E Bu CALCULATED (1) 3 3g STRESS ALLOWABLE (SERVICE IEVEL D)

SHEAR 2.56 12.84(2)

ASTM 8 = 36.0(2)

STRINGER y

A-36 3. $g,o BENDING 37.97 43.20(2) 32*1 SHEAR 0.76 25.68 SUPPORT S =

BEAM AT ASTM y

0.04 58.0 MITER A-36 S =

u BENDING 1.87 42.38 JOINT 8 P T COMPRESSIVE 1.25 30.00 ASME 3,

3g,y CO g 0.07 A*

AT MITER S =

60.0 GRADE 6 u

BENDING 1.22 41,18 JOINT SHEAR 7.27 25.68 32.1 INTERMEDIATE ASTM S

=

SUPPORT BEAM A-36 S

58.0

=

u BENDING 19.09 38.65 COMPRESSIVE 9.89 27.52 ASTM S =

26.7 INTERMEDIATE 0.63 A"333 PIPE STRUT S =

$5.0 GRADE 6 u

BENDING 8.86 35,24 II III 36.0 COMPRESSIVE 14.91 28.00 S

=

ANGLE ASTM y

0.86 BRACING A-36 S =

58.0 II U

BENDING 13.31 43.20 (1) VALUES SHOWN ARE OBTAINED FROM BEAM INTERACTION EQUATION.

(2) VALUES CONSIDERE., ARE FOR ACTUAL TEMPERATURE.

(3) TIME PHASING OF THE RESPONSE IS NOT CONSIDERED. THE PEAK-TO-PEAK VALUES ARE CONSERVATIVELY USED.

i l

l l

l COM-02-039-4 Revision 0 4-2.18 nutgg])

Table 4-2.5-2 k'

MAXIMUM SUPPRESSION CHAMBER SHELL STRESSES AT CATWALK REINFORCEMENT BEAM LOCATIONS STRESS CALCULATED CALCULATED TYPE STRESS (ksi)

ALLOWABLE PRIMARY 11.94 0.41 MEMBRANE LOCAL PRIMARY 28.46 0.98 MEMBPANE PRIMARY +

SECONDARY 52.32 0.75 STRESS RANGE I

Q' COM-02-039-4 Revision 0 4-2.19 nutagh

i 1

4-2.5.1 Closure The values of the loads used to evaluate the internal structures are conservative estimates of the loads postulated to occur during an actual LOCA or SRV discharge event.

The event combinations for which the internal structures are evaluated envelop the actual events expected to occur during a LOCA or SRV discharge event.

The acceptance limits to which the evaluation results are compared are more restrictive than those required by NUREG-0661.

Use of these acceptance limits ensures that the internal structures will not fail and cause damage to safety-related components.

The analysis results presented show that stresses in the internal structure components are within these conservative acceptance limits.

The NUREG-0661 criteria are therefore considered to be met, l

l COM-02-039-4 Revision 0 4-2.20 nutggh

4-3.0 LIST OF REFERENCES 1.

" Mark I

Containment Long-Term Program,"

Safety Evaluation Report, U SN RC, NUREG-0661, July 1980; Supplement 1, August 1982.

2.

" Mark I

Containment Program Load Definition Report,"

General Electric

Company, NEDO-21888, Revision 2, November 1981.

3.

" Mark I Containment Program Structural Acceptance Criteria Plant Unique Analysis Application Guide,"

Task Number 3.1.3, Mark I owners Group, General Electric Company, NEDO-2 4 583, Revision 1,

October 1979.

4.

ASME Boiler and Pressure Vessel Code,Section III, Division 1,

1977 Edition with Addenda up to and including Summer 1977.

O

\\

COM-02-039-4 Revision 0 4-3.1 s

l l

nutg_qh t

e QUAD CITIES STATION UNITS 1 & 2 i

MARK I PLANT UNIQUE l

l ANALYSIS REPORT i

i O

VOLUME 5 O

l MM NWEALTH E IS N

MPANY O

SARGENT&LUNDY

. _ _., _ _.