OIR15 SNUBBER TESTING SCOPE March 9,1998 ATTACHMENT 1 QUAD CITIES STATION UNIT 1 REFUEL OUTAGE Q1R15 l

TECHNICAL SPECIFICATION 314.8.F SNUBBER FUNCTIONAL TESTING SCOPE l

QUAD CITIES UNIT 1 TECH SPEC (SAFETY RELATED) SNUBBER POPULATION IS 118 SNUBBERS l

A. FUNCTIONAL TESTING SCOPE l

1.

TECHNICAL SPECIFICATION 10% SAMPLE:

a.

Testing will be performed with the following procedures:

e QCAP 0410-05 e QCTS 0750-05 b.

Breakdown of the sample is:

6 snubbers in the Drywell e

4 snubbers in the Reactor Building e

e 2 snubbers in the MSIV Room c.

System breakdown of the 10% sample:

Tech Spec Snubbers:

TECH SYSTEM NWR8 SERIAL SNUBBER ISI NUMBER LOCATION DRAWBIG SPEC TYPE.

NURSER Ale SIZE 1-1*

1400 960046385-01 3205 PSA-10 1403-W-103 DRYWELL 3RD LEVEL M-983D-254 A&B 1 18' 0202 96004291541 1066 PSA-35 0200 M 110 DRYWELL 1ST LEVEL M-990D-273 1-33 0300 900042911-01 2678 PSA-1 NON40DE DRYWELL 1ST LEVEL M-1053-EM-SHT.1,2,3 1-39 1600 960042909-01 8713 PSA-1/2 NON CODE REACTOR BLDG M433-SHT. 35 BASEMENT 1 46*

0202 960042793-01 25170 PSA-3 0200 M-174 ORYWELL iST LEVEL M-990D-4 1-55 3000 960042908-01 6858 PSA-35 NON CODE nit,IV ROOM M-9880-7 1-56 3000 960042841-01 6865 PSA-35 NON-CODE MSiv ROOM M-988D4 1

1-59 3000 960042840 41 61293/99 LISEGA-4 NON-CODE DRYWELL 1ST LEVEL M-328A SHT.10 1

144*

3000 960042837-01 61278/94 LISEGA-5 30018-M-101.2 DRYWELL 2ND LEVEL M-328B SHT. 7 l

141 1000 900042835-01 778 PSA 100 NON-CODE REACTOR BLDG M-1602-03 BASEMENT 1 110*

1000 960042807-01 12726 PSA-10 10128-M-203.1 REACTOR BLDG TOP OF M-1611 15 TORUS 1 128' 0300 960042790-01 24663 PSA-3 0328-M-201 REACTOR BLDG iST M-98501022 FLOOR -

2.

FAILURE TRENDING SAMPLE, SERVICE LIFE MONITORING AND TESTING RESULTS FROM Q1R14 AND Q1P01:

a.

Breakdown of the sample is:

8 snubbers in the Drywell e

9804290118 980424 PAGE 1 OF 2 PDR ADOCK 05000254 P

PDR

Olk15 SNUBBER TESTING SCOPE c.

System breakdown:

TECH SYSTEM NWR8 SERIAL SNUBBER ISI NUMBER LOCATION DRAWING SPEC TYPE NUMBER AND SIZE 1-044*

0200 980023967 01 7399 PSA-10 0200-M-172 DRYWELL iST LEVEL M-990D-2 SHT.1 1-045*

0200 980023966-01 16917 PSA-10 0200-M-175 DRYWELL iST LEVEL M-990D-3 1-061 3000 9600463874 1 61293/98 LISEGA 4 NON-CODE DRYWELL 1ST LEVEL M-328A SHT.13 1-067*

2300 980024516-01 16919 PSA-10 2305-M-101.1 DRYWELL 1ST LEVEL M-328B SHT. 37 1-122*

1000 980024210-01 30694 PSA-3 1025-M-101 A&B DRYWELL 1ST LEVEL M-9940-22 SHT.1.2,3 1-123*

1000 980023968-01 9481 PSA-3 1025-M-101 A&B DRYWELL 1ST LEVEL M-994D-22 SHT.1,2,3 1-124*

1000 960042789-01 7333 PSA-3 1025-M-102 A&B DRYWELL 1ST LEVEL M-994D-23 SHT.1,2,3 1-125*

1000 980024211-01 11709 PSA-3 1025-M-102 A&B DRYWELL iST LEVEL M-9940-23 SHT.1.2.3

[

0 (;@: Y ? ~$

n MichaelNmpeo Snubber Coordinator x2165 Pager# 354 Engineering Programs Group w!/l E24MiiLDate: 3 Nf Wary /j6nverS'e Snu%r Coordinator Back-up x2179 Pager# 639

)

Engineering Programs Group l

PAGE 2 0F 2