l Quad Cities Unit 1 Cycle 14 Core Operating Limits Report t

9406090065 940531 PDR ADOCK 05000254 l

P PDR i

l

\\

Core Operating Limits Report ISSUANCE OF CHANGES

SUMMARY

Affected Affected Section Pages Summary of Changes Date All All Original issue (Cycle 11) 06/89 All All Original issue (Cycle 12) 10/90 All All Original issue (Cycle 13) 11/92 2

iv, 2 Converted Figures 2-1 through 2-8 to 01/93 2 2-8 actual tables from References 4 and 5 All All Original issue (Cycle 14),

3/94 2,4,5 2,4,5 Added Section 2.3 on SLO, Revised Section 4.2 requiring OLMCPR penalty during coastdown operation, Added Section 5.0 on Analytical Methods i

l Quad Cities Unit 1 Cycle 14

\\

Core Operating Limits Report i

TABLE OF CONTENTS REFERENCES..

..iii LIST OF TABL _.

.. iv l

LIST OF FIGURES........

..v i

1.0 CONTROL ROD WITHDRAWAL BLOCK INSTRUMENTATION..........

.1 1.1. TECHNICAL SPECIFICATION

REFERENCE:

.1

1.2. DESCRIPTION

.1 2.0 AVERAGE PLANAR LINEAR HEAT GENEPsATION RATE (APLHGR)..

.2 2.1 TECHNICAL SPECIFICATION

REFERENCE:

..2

2.2 DESCRIPTlON

.2 3.0 LIN EAR HEAT CENERAT ON RATE (LHC R)............................

.3 3.1 TECHNICAL SPECIFICATION

REFERENCE:

.............................. 3 3.2 D ES C R I PTI O N :................................................................. 3 I

4.0 MINIMUM CRITICAL POWER RATIO (MCPR).................................... 4 i

4.1 TECHNICAL 5PECIFICATION

REFERENCE:

............................... 4 4.2 DESCRIPT?ON:.............

...................................................4 r

5.0 AN ALYTIC AL M ETHODS:.....................

.........................................S t

P il Quad Cities Unit I Cycle 14

i i

Core Operating Limits Report REFERENCES r

1.

Commonwealth Edisc i Company and lowa-lllinois Gas and Electric Company i

Docket No. 50-254, Quad Cities Station, Unit 1 Facility Operating License, t

License No. DPR-29.

2.

Letter from D. M. Crutchfield to All Power Reactor Licenses and Applicants, Generic Letter 88-16; Concerning che Removal of Cycle-Specific Parameter Limits from Technical Specifications.

3.

Supplemental Reload Licensing Report for Quad Cities Nuclear Power Station, Unit 1 Reload 13 Cycle 14,23A7229, Revision 1, Class I, March 1994.

4.

Quad Cities Nuclear Power Station, Units I and 2, SAFER /GESTR - LOCA Loss-of-Coolant Accident Analysis, NEDC-31345P, Revision 2. Class lil, July 1989 (as amended).

5.

Extended Operating Domain and Equipment Out Of Service for Quad Cities Nuclear Power Station Units 1 and 2, NEDC-31449, Revirn 1, Class 11, April 1992.

6.

GE document GENE-637-03', 2 193, Class 11. " Analysis of End of Full Power Capability Coastdown with Load Following for Quad Cities I and 2, dated November,1993.

4 iii Quad Cities Unit 1 Cycle 14 1

Core Operating Limits Report LIST OF TABLES Table Title Page 2-1 Maximum Average Planar Linear Heat Generation 2-1 Rate (MAPLHGR) vs. Average Planar Exposure for GE8B P8DQB300-7G4.0-80M-4WR-145-T.

2-2 Maximum Average Planar Linear Heat Generation 2-2 Rate (MAPLHGR) vs. Average Planar Exposure for G E8 B-P8 DQB300-9G4.0- 80M-4WR-14 5-T.

2-3 Maximum Average Planar Linear Heat Generation 2-3 l

Rate (MAPLHGR) vs. Average Planar Exposure for G E88-P8 DQB 301 -9GZ-80M-4WR-14 5-T.

l i

2-4 Maximum Average Planar Linear Heat Generation 2-4

)

Rate (MAPLHGR) vs. Average Planar Exposure for G E98-P8 DWB2 58-4G4.0/3 G 3.0-80M-14 5-T.

i 2-5 Maximum Average Planar Linear Heat Generation 2-5 Rate (MAPLHCR) vs. Average Planar Exposure for i

GE98-P8DWB258-9GZ-80M 145-T.

2-6 Maximum Average Planar Linear Heat Generation 2-6 Rate (MAPLHCR) vs. Average Planar Exposure for GE9B P8DWB305-7GZ-80M-145-T.

2-7 Maximum Average Planar Linear Heat Generation 2-7 Rate (MAPLHCR) vs. Average Planar Exposure for GE10-P8HXB311-8GZ-100M 145-T 2-8 Maximum Average Planar Linear Heat Generation 2-8 Rate (MAPLHGR) vs. Average Planar Exposure for l

GE10 P8HXB312-7CZ 100M-145-T

\\

i f

i i

iv Quad Cities Unit 1 Cycle 14

Core Operating Limits Report LIST OF FIGURES i

Figure Title Page 4-1 Kf Factor vs. % Core Flow.

4-1 1

1 6

v Quad Cities Unit 1 Cycle 14

\\

Core Operating Limits Report 1.0 CONTROL ROD WITHDRAWAL BLOCK INSTRUMENTATION (3.2/4.2)

I 1.1.

TECHNICAL SPECIFICATION

REFERENCE:

Technical Snecification Table 3.2-3 and 3.6.H

1.2. DESCRIPTION

The Rod Withdrawal Block Monite.- Upscale Instrumentation Trip Setpoint for two recirculation loop operation is determined from the following relationship:

__ (0.65)Wd + 4 3% **

" Clamped, with an allowable value rmt to exceed the allowable value for recirculation loop drive flow (Wd) ui 100%.

Wd is the percent of drive flow required to produce a rated core flow of 98 million Ib/hr. Trip level setting is in percent of rated power (2511 MWth).

Page1 Quad Cities Unit 1 Cycle 14

1 f

Core Operating Limits Report 1

2.0 AVERAGE PLANAR LINEAR HEA F GENERATION RATE (APLHGR) (3.5/4.5) i 2.1 TECHNICAL SPECIFICATION

REFERENCE:

Technical Specification 3.5.1

2.2 DESCRIPTION

The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) versus Average Planar Exposure for GE8B P8DQB300-7G4.0-80M-4WR-145-T is determined from Table 2-1.

The Maximum Average Planar Linear Heat Generation Rates (MAPLHCR) versus Average Planar Exposure for GE88-P8DQB300-9G4.0-80M-4WR-145-T is determined from Table 2-2.

The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) versus Average Planar Exposure for GE88-P8DQB301-9GZ-80M-4WR-145-T is determined from Table 2-3.

The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) versus Average Planar Exposure for GE98 P8DWB258-4G4.0/3G3.0-80M-14 5-T is determined from Table 2-4.

The Maximum Average Planar Linear Heat Generation Rates (MAPLHCR) versus Average Planar Exposure for GE9B-P8DWB258-9GZ-80M-145-T is determined from Table 2 5.

The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) versus Average Planar Exposure for GE98-P8DWB305-7CZ-80M-145-T is determined from Table 2-6.

The Maximum Average Planar Linear Heat Cenaration Rates (MAPLHGR) versus Average Planar Exposure for GE10-P8HXB311-8GZ-100M-145-T is determined from Table 2-7.

The Maximum Average Planar Linear Heat Generation Rates (MAPLHCR) versus Average Planar Exposure for GE10-P8HXB312-7CZ-100M-145-T is determined from Table 2-8.

2.3 SINGLE LOOP OPERATION MULTIPLIER The tabulated values are multiplied by 0.85 whenever Quad Cities enters Single Loop Operation.

Page 2 Quad Cities Unit 1 Cycle 14

l Core Operating Limits Report TABLE 21 MAPLHGR vs. AVERAGE PLANAR EXPO 5JRE FOR BUNDLE TYPE GE8B-P8DQB300-7G4.0 80M-4WR-145-T LATTICE 565. P8DQLO71-NOG-80M 4WR-T LATTICE 584. P8DQL319-7G4.0-80M-4WR-T l

LATTICE 649 : P8DQLO71-7 gel-80M-4WR-T l

AVERAGE MAPLF.GR LIMITS (KW/FT)

PLANAR EXPOSURE 565 584 649 I

(GWd/S j')

0.2 11.34 11.58 11.34 2.0 11.26 11.78 11.26 4.0 11.40 12.34 11.40 6.0 11.55 12.87 11.55 8.0 11.66 13.14 11.66 10.0 11.72 13.37 11.72 l

I 12.5 11.48 13.33 11.48 15.0 11.15 13.00 11.15 20.0 10.46 12.36 10.46 39.8 6.14 6.14 46.3 7.12 I

Page 2-1 Q.uad Cities Unit 1 Cycle 14

Core Operating Limits Report TABLE 2-2 MAPLHGR vs. AVERAGE PLANAR EXPOSURE FOR BUNDLE TYPE GE88-P8DQB300 9G4.0-80M-4WR-145-T LATTICE 565. P8DQLO71-NOG 80M-4WR-T LATTICE 644 P8DQL320-9G4.0-80M-4WR-T LATTICE 686. P8DQLO71-9CE2-80M-4WR-T AVERAGE MAPLHGR LIMITS (KW/FT)

PLANAR EXPOSURE 565 644 686 (GWd/ST) 0.2 11.34 11.24 11.34 2.0 11.26 11.48 11.26 4.0 11.40 12.12 11.40 6.0 11.55 12.75 11.55 8.0 11.66 13.11 11.66 10.0 11.72 13.32 11.72 12.5 11.48 13.36 11.48 15.0 11.15 13.01 11.15 20.0 10.46 12.33 10.46 39.8 6.14 6.14 46.1 7.16 Page 2-2 Quad Cities Unit 1 Cycle 14

Core Operating Limits Report TABLE 2-3 J

MAPLHGR vs. AVERAGE PLANAR EXPOSURE FOR BUNDLE TYPE GE88-P8DQB301-9GZ-80M-4WR-145-T LATTICE 565 : P8DQLO71-NOC-80M-T LATTICE 854. P8DQL320-6G2.0-80M-T LATTICE 855 : P8DQL320-3G3.0/6G2.0-80M-T LATTICE 856 : P8DQLO71-9CE-80M-T AVERAGE MAPLHCR LIMITS (KW/FT)

PLANAR EXPOSURE 565 854 855 856 (CWd/ST) 0.0 11.57 12.18 11.41 11.57 0.2 11.50 12.23 11.49 11.50 1.0 11.30 12.34 11.63 11.30 2.0 11.28 12.60 11.94 11.28 3.0 11.33 12.89 12.34 11.33 4.0 11.40 13.01 12.61 11.40 5.0 11.48 13.14 12.82 -

11.48 6.0 11.55 13.24 13.02 11.55 7.0 11.61 13.31 13.18 11.61 8.0 11.66 13.34 13.28 11.66 9.0 11.69 13.35 13.34 11.69 10.0 11.72 13.35 13.37 11.72 12.5 11.44 13.33 13.31 11.44 ;

15.0 11.07 12.95 12.94 11.07 20.0 10.29 12.23 12.21 10.29 25.0 9.50 11.50 11.48 9.50 35.0 7.93 10.13 10.11 7.93 45.0 8.52 8.48 50.0 6.27 6.21 Page 2-3 Quad Cities Unit 1 Cycle 14

Core Operating Limits Report TABLE 2-4 MAPLHGR vs. AVERAGE PLANAR EXPO 5URE FOR BUNDLE TYPE GE98-P8DWB258 4G4.0/3G3.0 80M-145-T LATTICE 731 - P8DWLO71-NOC-80M-T LATTICE 1002 : P8DWL278-4G4.0/3G3.0-80M-T 1

LATTICE 1003 : P8DWL290-4G4.0/3G3.0 80M-T LATTICE 1004 P8DWLO71-7CE-80M-T AVERAGE MAPLHGR LIMITS (KW/FT)

PLANAR EXPO 5URE 731 1002 1003 1004 (GWd/ST) 0.0 11.64 12.02 11.23 11.64 0.2 11.57 12.09 11.30 11.57 1.0 11.38 12.25 11.47 11.38 2.0 11.36 12.46 11.69 11.36 3.0 11.41 12.66 11.98 11.41 4.0 11.49 12.86 12.20 11.49 5.0 11.56 13.07 12.40 11.56 6.0 11.63 13.20 12.54 11.63 7.0 11.69 13.30 12.69 11.69 8.0 11.74 13.40 12.84 11.74 9.0 11.78 13.46 12.97 11.78 10.0 11.81 13.50 13.06 11.81 12.5 11.54 13.44 13.04 11.54 15.0 11.16 13.07 12.79 11.16 20.0 10.37 12.34 12.29 10.37 25.0 9.58 11.66 11.75 9.58 35.0 8.01 10.34 10.24 8.01 43.7 4.71 4.71 45.0 8.33 8.15 50.9 5.10 52.4 4.90 Page 2-4 Quad Cities Unit 1 Cycle 14

Core Operating Limits Report TABLE 2-5 MAPLHGR vs. AVERAGE PLANAR EXPOSURE FOR BUNDLE TYPE GE98-P8DWB258-9GZ-80M-145-T LATTICE 731 P8DWLO 71 -NOG-80M-T LATTICE 1005 P8DWL277-7G3.0-80M-T LATTICE 1006 P8DWL288-7G3.0-80M-T LATTICE 1007 P8DWL288-2C4.0/7G3.0-80M-T LATTICE 1008 : P8DWLO71-9CE-80M-T AVERAGE MAPLHGR LIMITS (KW/FT)

PLANAR EXPOSURE 731 1005 1006 1007 1008 (GWd/ST) 0.0 11.64 12.07

!1.27 10.75 11.64 0.2 11.57 12.14 11.35 10.85 11.57 1.0 11.38 12.33 11.55 11.04 11.38 2.0 11.36 12.56 11.80 11.33 11.36 3.0 11.41 12.79 12.10 11.70 11.41 4.0 11.49 13.03 12.31 11.99 11.49 5.0 11.56 13.23 12.53 12.25 11.56 6.0 11.63 13.33 1 2.71 12.47 11.63 7.0 11.69 13.41 12.84 12.67 11.69 8.0 11.74 13.45 12.94 12.86 11.74 9.0 11.78 13.47 13.00 12.99 11.78 10.0 11.81 13.47 13.05 13.08 11.81 12.5 11.54 13.41 13.02 13.03 11.54 15.0 11.16 13.04 12.77 12.78 11.16 20.0 10.37 12.32 12.27 12.28 10.37 25.0 9.58 11.64 11.73 11.73 9.58 35.0 8.01 10.32 10.23 10.20 8.01 43.7 4.71 4.71 45.0 8.33 8.15 8.12 50.7 5.12 50.9 5.09 52.4 4.89 Page 2-5 Quad Cities Unit 1 Cycle 14

Core Operating Limits Report TABLE 2-6 MAPLHGR vs. AVERAGE PLANAR EXPOSURE FOR BUNDLE TYPE GE98-P8DWB305-7GZ-80M-145-T LATTICE 731 P8DWLO71-NOG-80M-T LATTICE 1516 P8DWL339-3G4.0/4G3.0-80M-T LATTICE 1517 : P8DWL339-7G3.0-80M-T LATTICE 1518 P8DWL324-7G3.0-80M-T LATTICE 1061 P8DWLO71-7CEl 80M-T AVERAGE MAPLHCR LIMITS (KW/FT)

PLANAR EXPO 5URE 731 1516 1517 1518 1061 (GWD/ST) 0.0 11.64 12.00 12.00 11.97 11.64 0.2 11.57 12.10 12.11 12.04 11.57 1.0 11.38 12.26 12.27 12.11 11.38 2.0 11.36 12.42 12.44 12.31 11.36 3.0 11.41 12.59 12.60 12.59 11.41 4.0 11.49 12.74 12.75 12.91 11.49 5.0 11.56 12.88 12.89 13.09 11.56 6.0 11.63 13.01 13.01 13.23 11.63 7.0 11.69 13.10 13.06 13.36 Ih69 8.0 11.74 13.13 13.09 13.48 11'.74 9.0 11.78 13.15 13.12 13.54 11.78 10.0 11.81 13.16 13.15 13.56 11.81 12.5 11.54 13.07 13.08 13.52 11.54 15.0 11.16 12.72 12.73 13.12 11.16 20.0 10.37 12.04 12.05 12.35 10.37 25.0 9.58 11.39 11.40 11.60 9.58 35.0 8.01 10.15 10.15 10.19 8.01 43.7 4.71 4.71 45.0 8.69 8.69 8.68 50.7 5.90 50.7 5.89 51.2 5.78 Page 2-6 Quad Cities Unit 1 Cycle 14

Core Operating Limits Report TABLE 2-7 MAPLHGR vs. AVERAGE PLANAR EXPOSURE FOR BUNDLE TYPE GE10-P8HXB311-8GZ-100M-145-T LATTICE 1807 P8HXLO71-8CE-100M-CECO LATTICE 1806 P8HXL335-3G3.0-100M-CECO LATTICE 1805 P8HXL353 2G4.0/6G3.0-100M CECO

. LATTICE 1804 : P8HXL335 4G4.0/4G3.0-100M-CECO

~ LATTICE 1054 P8HXLO714?oG-100M-CECO AVERAGE MAPLHGR LIMITS (KW/FT)

PLANAR EXPOSURE 1054 1806 1805 1804 1807 (GWD/ST) 0.0 11.85 12.06 11.10 12.02 11.85 0.2 11.78 12.12 11.14 12.08 11.78 1.0 11.59 12.28 11.27 12.22 11.59 2.0 11.57 12.48 11.51 12.40 11.57 3.0 11.61 12.68 11.81 12.57 11.61 4.0 11.68 12.89 12.14 12.76 11.68 5.0 11.75 13.11 12.50 12.94 11.75 6.0 11.81 13.29 12.88 13.12 11.81 7.0 11.86 13.41 13.19 13.28 11.86 8.0 11.91 13.47 13.28 13.40 11.91 9.0 11.94 13.48 13.34 13.46 11.94 10.0 11.97 13.46 13.39 13.49 11.97 12.5 11.75 13.34 13.44 13.33 11.75 15.0 11.38 12.96 13.09 12.95 11.38 20.0 10.59 12.22 12.40 12.22 10.59 25.0 9.81 11.51 11.73 11.50 9.81 35.0 8.26 10.13 10.39 10.13 8.26 44.9 4.93 4.93 45.0 8.55 9.00 8.55 50.4 5.85 50.5 5.85 51.5 5.86 Page 2-7 Quad Cities Unit 1 Cycle 14

Core Operating Limits Report TABLE 2-8 MAPLHGR vs. AVERAGE PLANAR EXPOSURE FOR BUNDLE TYPE GE10-P8HXB312-7GZ-100M-145-T LATTICE 1811. P8HXLO71-7GE-100M-CECO LATTICE 1810 P8HXL336-7G3.0-100M-CECO LATTICE 1809 : P8HXL354-1 G4.0/6G3.0-100M-CECO LATTICE 1808 P8HXL336-3G4.0/4G3.0-100M CECO LATTICE 1054 P8HXLO71-nog-100M CECO AVERAGE MAPLHCR LIMITS (KW/FT)

PLANAR EXPOSURE 1054 1810 1809 1808 1811 (GWD/ST) 0.0 11.85 12.04 11.27 12.01 11.85 0.2 11.78 12.11 11.31 12.08 11.78 1.0 11.59 12.27 11.42 12.23 11.59 2.0 11.57 12.49 11.65 12.43 11.57 3.0 11.61 12.72 11.93 12.65 11.61 4.0 11.68 12.96 12.24 12.88 11.68 5.0 11.75 13.15 12.58 13.09 11.75 6.0 11.81 13.30 12.94 13.22 11.81 7.0 11.86 13.41 13.15 13.32 11.86 8.0 11.91 13.46 13.32 13.40 11.91 9.0 11.94 13.47 13.43 13.45 11.94 10.0 11.97 13.45 13.50 13.47 11.97 12.5 11.75 13.35 13.45 13.35 11.75 15.0 11.38 12.97 13.10 12.97 11.38 20.0 10.59 12.24 12.41 12.23 10.59 25.0 9.81 11.52 11.74 11.51 9.81 35.0 8.26 10.15 10.41 10.14 8.26 44.9 4.93 4.93 45.0 8.60 9.01 8.61 50.5 5.85 50.6 5.85 51.6 5.86 l

Page 2-8 Quad Cities Unit 1 Cycle 14

1 Core Operating Limits Report 3.0 LINEAR HEAT GENERATION RATE (LHGR) (3.5/4.5) i t

3.1 TECHNICAL SPECIFICATION

REFERENCE:

Technical Specification 3.5J

3.2 DESCRIPTION

A.

The LHCR limit is 14.4 Kw/ft for all fuel types in the Q1C14 core:

1.

GE8B P8DQB300-7G4.0-80M-4WR-14 5-T 2.

GE88 P8DQB300-9G4.0 80M-4WR-145-T 3.

GE88-P8DQB301 9GZ-80M-4WR-14 5-T 4.

GE98-P8DW8258-4 G4.0/3 G3.0-80M-14 5-T 5.

GE98-P8DW8258-9GZ-80M-145-T 6.

GE98 P8DW8305-7CZ-80M-145-T 7.

GE10 P8HXB311-8GZ-100M-145-T 8.

GE10-P8HXB312-7CZ-100M-145-T Page 3 i

Quad Cities Unit 1 Cycle 14

~

o..

Core Operating Limits Report 4.0 MINIMUM CRITICAL POWER RATIO (MCPR) (3.5/4.5) 4.1 TECHNICAL SPECIFICATION

REFERENCE:

Technical Specifications 3.5.K and 3.6.H

4.2 DESCRIPTION

During steady-state operation at rated core flow, the Operating Limit MCPR (OLMCPR) shall be greater than or equal:

1.29 for tave s 0.68 seconds 1.39 for tave 2 0.86 seconds (0. 5 5 7)tave +0.911 for 0.68 < tave < 0.86 seconds where tave -mean 20% scram insertion time for all surveillance data from Technical Specification 4.3.C which has been generated in the current cycle.

For core flows other than rated, these nominal values of OLMCPR shall be increased by a factor of Kf where Kfis as shown in Figure 4-1.

A cycle independent OLMCPR of 1.32 (Option B) was calculated (Reference 5) for operation with a Feedwater Heater Out of-Service (FWHOOS). Therefore, the OLMCPR, calculated using the abovd information, shall be increased by 0.03 whenever operating with a FWHOOS. This event, which conservatively bounds the requirements detailed within the EOD/EOOS document (Reference 5), goes beyond all normal operating conditions in the SRLR (Reference 3).

Q1C14 has been approved for operating up to 15% (Reference 6) above equilibrium coastdown power level with multiple control rods inserted.

At End of Full Power Capability (EFPC) a generic MCPR operating limit MCPR penalty of 0.06 must be added to the operating limit MCPR in order to exceed equilibrium coastdown power.

Page 4 Quad Cities Unit 1 Cycle 14

e FIGURE 4-1 Kf FACTOR 1.5 1.4

%s

...ei N

' '~

Autom

=~= ::;'stic a

Flow Contro!

52 1.2

---s N

N

's_.

N s_

1.1

- - - - - _ -' ~ = =.. ~ _ _

N Manual Flow Control N

"'s_,

i N

~N

---(-~--- %- - - -Mex Flow)--- - -

- - - - - - -N s_

07 -

1 0.9 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100105

% Core Flow Quad Cities Unit 1 Cycle 14 Core Operating Limits Report Page 4-1

[

Core Operating Limits Report 5.0 Analytical Methods The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC in the latest approved revision or supplement of the topical reports describing the methodology. For Quad Cities Unit 1, the topical reports are:

(1)

NEDE-24011-P A " General Electric Standard Application for Reactor Fuel,"

(latest approved revision).

(2)

Commonwealth Edison Topical Report NFSR-0085," Benchmark of BWR Nuclear Design Methods,"(latest approved revision).

(3)

Commonwealth Edison Topical Report NFSR-0085, Supplement 1,0uad Cities Gamma Scan Comparisons,"(latest approved revision).

(4)

Cornmonwealth Edison Topical Report NFSR-0085, Supplement 2, Design Methods - Neutronic Licensing Analyses," (latest approved revision).

1 Page 5 Quad Cities Unit 1 Cycle 14