ML20125B530
ML20125B530 | |
Person / Time | |
---|---|
Site: | Quad Cities |
Issue date: | 12/03/1992 |
From: | COMMONWEALTH EDISON CO. |
To: | |
Shared Package | |
ML20125B528 | List: |
References | |
NUDOCS 9212100044 | |
Download: ML20125B530 (17) | |
Text
-
i I
. l 3
a i
i QUAD CITIES UNIT 1 CYCLE 13-
)
i CORE OPERATING LIMITS REPORT 9
i 9212100044 921203 PDR ADOCK 05000254 P PDR
4 Core Operating . Limits Report ISSUANCE OF CHANGES
SUMMARY
Affected Affected Sectica Pages Summary of Changes Date All All Original Issue (Cycle 11) 06/89 All All Original Issue (Cycle 12) 10/90 All All Original Issue (Cycle 13) 11/92 i
i Quad Cities Unit 1 Cycle 13
Core Opemting Limits Report 4
4
.I
, TABLE OF CONTFETS REFEREN C ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii LI ST OF FI G URES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i v 1.0 CONTROL ROD WITHDRAWAL BLOCK INSTRUMENTATION I
(3.2/4.2) ............. ..... .... ..................... .......... .......... .. ... ... 1 1.1. TECHNIC AL S PECIFICATION
REFERENCE:
. . . . . . . . . . . . . . . . . . . . . . . I
1.2. DESCRIPTION
...... ..... ............... .. ............... ........... 1 2.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)
(3.5/4.5)..............................................................................2 2.1 TECHNICAL SPECIFICATION
REFERENCE:
. . ........ . ...... .. .. . 2
2.2 DESCRIPTION
- . . ...... .............................. ............. ..... 2 1
3.0 LINEAR HEAT GENERATION RATE (LHGR) (3.5/4.5) ........ . .. ..... 3 3.1 TECHNICAL SPECIFICATION
REFERENCE:
.... .. ....... ..... 3
3.2 DESCRIPTION
- .... .... . ..... ... ....................... .... . .... . 3 4.0 MINIMUM CRITICAL POWER RATIO (MCPR) (3.5/4.5)..... ........ ... 4 4.1 TECHNIC AL S PECIFIC ATION
REFERENCE:
. . . . . . . . . . . . . . . . . . . . . . 4 i
4.2 DES C RIPTI ON : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 11 Quad Cities Unit 1 Cycle 13
Core Operating Limits Report REFERENCES
- 1. Commonwealth Edison Company and Iowa-Illinois Gas and Electric Company Docket No. 50-254, Quad Cities Station, Unit 1 Facility Operating License, License No. DPR-29
- 2. Letter from D. M. Crutchfield to All Power Reactor Licenses and Applicants, Generic Ixtter 88-16; Concerning the Removal of Cycle-Specific Parameter Limits from Technical Specifications.
- 3. Supplemental Reload Licensing Report for Quad Cities Nuclear Power Station, Unit 1 Reload 12 Cycle 13,23A7176, Revision 0, Class I, April 1992.
l 4
- 4. Quad Cities Nuclear Power Station, Units 1 and 2, SAFER /GESTR - LOCA Loss-of-Coolant Accident Analysis, NEDC-31345P, Revision 2, Class III, July 1989 (as amended).
- 5. General Electric Standard Application for Reactor fuel (GESTAR),
NEDE-24011-P-A-10, Class III, February 1991.
- 6. Extended Operating Domain and Equipment Out-Of-Service for Quad Cities Nuclear Power Station Units 1 and 2, NEDC-31449, Revision 1, Class II, July 1992.
- 7. General Electric Procedure Y1003V43, ' Thermal-Mechanical Limit Evaluation,'
Revision 4, Fehmary 1991.
i iii Quad Cities Unit 1 Cycle 13
Core Operating Limits Report i
- - LIST OF FIGURES Figure Title Page i
. Maximum Avemge Planar Linear Heat Genemtion l 2-1 Rate (MAPLHGR) vs. Average Planar Exposure for 2-1 i GE7B-P8DRB299-7G4.0-80M-145-T.
4
{ Maximum Average Planar Linear Heat Generation j 2-2 Rate (MAPLHGR) vs. Average Planar Expusure for 2-2
- GE7B-P8DRB282-7G3.0-80M-145-T.
- Maximum Average Planar Linear Heat Generation 2-3 Rate (MAPLHGR) vs. Average Planar Exposure for 2-3
! G E8B-P8 DQB300-7G4-80M-4WR- 145-T.
I
! Maximum Average Planar Linear Heat Generation
! 2-4 Rate (MAPLHGR) vs. Average Planar Exposure for - 2-4 GEf 3-P8DQB300-9G4-80M-4WR-145-T.
t Maximum Average Planar Linear Heat Generation i 2-5 Rate (MAPLHGR) vs. Average Planar Exposure for 2-5 G E8 B-P8 DWB301 -9 G Z- 80M-4WR- 145 -T.
l Maximum Average Planar Linear Heat Generation i 2-6 Rate (MAPLHGR) vs. Average Planar Exposure for 2-6
- G E9B-P8 DWB258-4G 4/3 G3-80M- 145-T.
{ Maximum Avenge Planar Linear Heat Generation
- 2-7 Rate (MAPLHGR) vs. Average Planar Exposure for 2-7 i GE9B-P8DWB258-9GZ-80M-145-T.
i Maximum Average Planar Linear Heat Generation 1
2-8 Rate (MAPLHGR) vs. Average Planar Exposure for 2-8 i- GE9B-P8DWB305-7GZ-80M-145-T.
4-1 Kf Factor vs. Core Flow %. 4-1 4
iv 0
i-4 Quad Cities Unit 1 Cycle 13 i
Core Operating Limits Report 1.0 CONTROL ROD WITIIDRAWAL 3 LOCK INSTRUMENTATION (3.2/4.2) l.1. TECHNICAL SPECIFICATION
REFERENCE:
Technical Specification Table 3.2-3 and 3.6.H
1.2. DESCRIPTION
The Rod Withdrawal Block Monitor Upscale Instnamentation Trip Setpoint for two recirculation loop opemtion is determined from the following relationship:
s (0.65)Wd + 43 % **
4
- Clamped, with an allowable value not to exceed the allowable vahte for recirculation loop drive flow (Wd) of 100%.
Wd is the percent of drive flow required to produce a rated core flow of 98 million Ib/hr. Trip level setting is in percent of rated power (2511 MWth).
f a
'f I
J Pagei Quad Cities Unit 1 Cycle 13
a Core Operating Limiis Report i
j .2.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)- (3.5/4.9 4
-2.1 TECHNICAL SPECIFICATION
REFERENCE:
i-Technical Specification 3.5.I i 2.2 DESCRIWION:
! The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR).
versus Average Planar Exposure for GE7B-P8DRB299-7G4.0-80M-145-T i is determined from Figure 2-1.
l l The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR)
{ versus Average Planar Exposure for GE7B-P8DRB282-7G3.0-80M-145-T
{ is determined from Figure 2-2.
I
! The Maximum Average Pl: tar Linear Heat Genemtion Rates (MAPLHGR)
' Versus Avemge Planar Exposure for GE8B-P8DQB300-7G4 80M-4WR-145-T
- i. is determined from Figure 2-3.
i
- The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) versus Average Planar Exposure for GE8B-P8DQB300-9G4-80M-4WR-145-T is determined from Figure 2-4.
1 The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) l Versus Avemge Planar Exposure for GE8B-P8DWB301-9GZ-80M-4WR-145-T is deteimined from Figure 2-5.
! The Maximum Average l'lanar Linear Heat Generation Rates (MAPLHGR) versus Average Planar Exposure for GE9B-P8DWB258-4G4/3G3-80M-145 T is determined from Figure 2-6.
The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) versus Average Planar Exposure for GE9B-P8DWB258-9GZ-80M-145-T is determined from Figure 2-7.
The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) versus Average Planar Exposure for GE9B-P8DWB305-7GZ-80M-145-T -
is determined from Figure 2-8.
i Page 2 1
Quad Cities Unit 1 Cycle 13 4
, . , _ . . _ , , . , . e-_ , , , . - , , ,,r,v., ,, y, _.,-..,,..,,..-+,m,-,. . c # -, e.r m , .w,w, ,,,
MAPLHGR vs. Average Planar Exposure -
~
i GE7B-P8DRB299-7G4.0-80M-145-T i
MAPLHGR (kW/ft) 14 i , :
1 ! l !
t i.
12 4
?
--./*y ii i
- N1 i
10 - - - - -- - -- N sj- -
j 7-i N.
- i !
I _ - - - . - . . .... -
4.- . . - , _.
t I
- i j' 6 0 10 20 30 40 i
Average Planar Exposure (GWd/ST)
! + Figure 2-1 i
Quad Cities 1 Cycle 13 l
Core Operating Umits lleport j Page 2-1 i i
- MAPLHGR vs. Average Planar Exposure -
~
.GE7B-P8DRB282-7G3.0-80M-145-T MAPLHGR (kW/ft) 14
- j
! i 12 T -----
T 4
... ' / w_;; N* ;
l i
I .
! 10 - - -- - - -
-l-
-f --- N - ~. b- -
g ___ . _ - _ . _ . _ . . _ . . _ _ _ . . . . _ _ _ . _ _ . . , . . _ _,L._._. . .._ _.._ _ . _
+._.._. ..._..._...__-i_.____.____.
l
! 6
- 0 10 20 30 40 ,
- Average Planar Exposure (GWd/ST)
-+-Figure 2-2 l
l Quad Cities Unit 1 Cycle 13 i Core Operating Limits Report Page 2-2
e MAPLHGR vs Average Planar Exposure -
~
! GE8B-P8DQB300-7G4-80M-4WR-145-T
, MAPLHGR (kW/ft) 14 : , , ;
i !
i 12 -- / -
4
.s x.%x\ :
l I
L 10 - - -
i
- \-- --
7 l -
) i ; j !
~
l !
! 8 - -~ ~ - - ' -
-L -- - -
i - - - - - --
A --
N*
i '; '!
- l. 6
! 0 10 20 30 40 i
Average Planar Exposure (GWd/ST)
+ Figure 2-3 i
i Quad Cities Unit 1 Cycle i3 Core Operating Umits Report i Page 2-3 l
MAPLHGR vs Average Planar Exposure -
GE8B-P8DQB300-9G4-80M-4WR-145-T
~
MAPLHGR (kW/ft) 14 , ,
+-.x ~
/./. N o,,N i
12 -
,/ -
l ;
l '\) !
10 --
1 lN -- -
i i
i j e -. . . : .- . . --
- _7 i ! i s.
y j !
I '
! 6 j- 0 10 20 30 40
- Average Planar Exposure (GWd/ST) i j + Figure 2-4 1
- f Quad Cities Unit 1 Cycle 13 Core Operating Limits Report Page 2-4
MAPLHGR vs. Average Planar Exposure GE8B-P8DWB301-9GZ-80M-4WR-145-T MAPLHGR (kW/ft) i i
, .* . . . -. .i. s .
t i ,
13 -- -
, .N 4 11 --
+ l- N I- - -
! I i .
- i ,
a i I i 9 - -
-t-N NN
- 7 -- -- -
r- - - - - - -
- r --
i -- - s N;
i I
! 5 O 10 20 30 40 50 l Avurage Planar Exposure (GWd/ST) l + Figure 2-5 l
i l'
! Quad Cities Unit 1 Cycle 13 l Core Operating Umits Report -
l Page 2-5
MAPLHGR vs. Average Planar Exposure -
GE9B-P8DWB258-4G4/3G3-80M-145-T l MAPLHGR (kW/ft) 14 ; ; , j
.~* x ;:
, i i 1, i
12 + qN.
i 10 -
,i
~.N x - - -- --
8 - --
N-!
! i
- 6 -
- - - + -- - - - - - - - - - - - -
- - m i- -
! i N j ,,
i 4 j o 10 20 30 40 50 Average Planar Exposure (GWd/ST)
- -Figure 2 !
j Quad Cities Unit 1 Cycle 13 j Core Operating Limits Report
, Page 2-6
MAPLHGR vs. Average Planar Exposure
~
GE9B-P8DWB258-9GZ-80M-145-T
., MAPLHGR (kW/ft) 14 : ; ; j
,:'*.."..-4-.s* ;
N *- i ,
12 +
N.,~ y, t -
' ~
10 - - -
8 --
1 4--- -
N C I
i
! \s l 6 -- ~ - - -
- - - -- - i - - - -
h +- - -
- ~.
l : i
- i
' I ' l
! 4 i 0 10 20 30 40 50 !
I j Average Planar Exposure (GWd/ST) l + Figure 2-7 i
i l Quad Cities Unit 1 Cycle 13 l~ Core Operating Limits Report i
Page 2-7 1
MAPLHGR vs. Average Planar Exposure GE9B-P8DWB305-7GZ-80M-145-T MAPLHGR (kW/ft)
! ! ! l I
13
- ,. y ... + *-*~*~* ~x *e -,
- xx . x . ,
l
, 11 -
i- !
l 7
l N *x
- t j
9 _ _ i -
- j. - ._ _
x
- I
! \x 7 - -- ~ - --
I ' '
- 5 i 0 10 20 30 40 50 l Average Planar Exposure (GWd/ST) i l + Figure 2-8 i
f
! Quad Cities Unit 1 Cycle 13 j, Core Operating Umits Report
- Page 2-8 i
- - _ . . - - . - . - . - . - - . ~ . . . - . . . _ . . - . _ . - . . . . - - - _ - - -
I
- Core Operating Limits Report 4
i i
V ;
j 3.0 LINEAR IIEAT GENERATION RATE (LILG_R) (3.5/411 i l 3.1 TECHNICAL SPECIFICATION
REFERENCE:
i I
! Technical Specitication 3.5.J j
i
3.2 DESCRIPTION
i f A. The LHGR limit is 13.4 Kw/ft for fuel types:
! 1. GE7B-BP8DRB299-7G4.0-80M-145-T i 2. GE7B-BP8DRB282-7G3.0-80M-145-T i
i i
! B. The LHGR liinit is 14.4 Kw/ft for fuel types:
- 1. GE8B-P8DQB300-7G4 80M-4WR-145-T i 2. GE8B-P8DQB300-9G4-80M-4WR 145-T 4 3. GE8B-P8DWB301-9GZ-80M-4WR-145-T l 4. GE9B-P8DWB258-4G4/3G3-80M 145-T l 5. GE9B-P8DWB258-9GZ-80M-145-T l 6. GE9B-P8DWB305-7GZ-80M-145-T l
i i
l I
i 3
1
?
i i
i l Page 3 j Quad Cities Unit 1 Cycle 13 r
v-,m. ., , .,.A--,,,,...___,,._...,_., _ _ . . - ~ , , , , ,... - - , ..-,.. _ , ..- ,,.
..m_..._,,,. ..-.--,.-,.J._.,-_,,~..
Core Operating Limits Report 4.0 511NINIUNI CRITICAL POWER RATIO (N1CPR) (3.5/4.5) 4.1 TECHNICAL SPECIFICATION
REFERENCE:
4 Technical Specifications 3.5.K and 3.6.H 4.2 DESCRII' HON:
A q During steady-state operation at rated core flow, the Operating Limit htCPR (OLhiCPR) shall be greater than or equal:
- 1.27 for t ave s 0.68 seconds 1.37 for t ave 2 0.86 seconds (0.556)ta ve +0.892 for 0.68 < tave < 0.86 seconds where ta ve = mean 20% scram insertion time for all suneillance data from Technical Specification 4.3.C which has been generated in the current cycle.
For core flows other than rated, these nominal values of OLhtCPR shall be increased by a factor of Kf where Kf is as shown in Figure 4-1.
A cycle independent OLhtCPR of 1.31 (Option B) was calculated (Reference 6) for operation with a Feedwater Heater Out-of-Service (FWHOOS). Therefore, the OLhfCPR, calculated using the above information, shall be incmased by 0.04 whenever operating with a FWHOOS. This event, which conservatively bounds the requirements detailed within the EOD/EOOS document (Reference 6), goes beyond all normal opemting conditions in the SRLR j (Tleference 3).
Page 4 Quad Cities Unit 1 Cycle 13
..r ..
-., ,