Coro Operating Limits Report May,1996 ISSUANCE OF CHANGES

SUMMARY

Affected Affected Section Pages Summary of Changes Date All All Original issue (Cycle 11).

06/89 All All Original issue (Cycle 12).

10/90 All All Original issue (Cycle 13).

11/92 2

iv,2 Converted Figures 2-1 through 2-8 to actual 01/93 i

2 2-8 tables from References 4 and 5.

All All Original issue (Cycle 14),

3/94 2,4,5 2,4,5 Added Section 2.3 on SLO, Revised Section 4.2 requiring OLMCPR penalty during coastdown operation, Added Section 5.0 on Analytical Methods.

All All Original Issue (Cycle 15), Latest Date Revised 5/96 added to aach COLR page, Added Special Instructions and boxed in TSUP References for TSUP Implementation, Added Control Rod Withdrawal Block Equation for Single Loop Operation.

l i

DOOK050054 Oued Cities Unit 1 Cycle 15 DR P

PDR

_=.

Cora Operating Limits Rsport May,1996 TABLE OF CONTENTS l

t S PE C I A L I N STR U CTI O N S.........................................................................

REFERENCES................................................................................................iv L I ST O F TA B L E S........................................................................................

l L I S T O F FI G U R E S......................................................................................

l 1.0 CONTROL ROD WITHDRAWAL BLOCK INSTRUMENTATION................1 1.1. TECHNICAL SPECIFICATION

REFERENCE:

....................................1 i

i

1. 2. D E S C R I PTI O N :............................................................................1 2.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)......... 2 l

2.1 TECHNICAL SPECIFlCATION

REFERENCE:

.................................... 2 2.2 D E S C R I PTI O N :........................................................................... 2 3.0 LINEAR HEAT GENERATION RATE (LHGR).......................................... 3 3.1 TECHNICAL SPECIFICATlON

REFERENCE:

................................... 3 l

3. 2 D E S C R I PTI O N :........................................................................... 3 4.0 MINIMUM CRITICAL POWER RATIO (MCPR)........................................ 4 4.1 TECHNICAL SPECIFICATION

REFERENCE:

.................................... 4 4.2 D E S C R I PTI O N :........................................................................... 4 5.0 A N ALYTl C A L M ETH O D S :..................................................................... 5 l

l l

l 4

I

..ll i

d Quad Cities Unit 1 Cycle 15

/

t

/

[

Ccra Operating Limits RIport May,1996 SPECIAL INSTRUCTIONS 1.

This Core Operating Limits Report (COLR) contains the applicable reactor core limits and operational information mandated by Technical Specification 6.6.A.4, (TSUP Section 6.9.A.6). When the COLR is referenced by applicable Technical Specifications or procedures for Technical Specification compliance, a controlled copy of this report shall be used as the official source of the applicable limit or requirement.

2.

Implementation of the Technical Specification Upgrade Program (TSUP): The referenced Techincal Specifications in this Report contain a notation as shown below, when indicating the applicable TSUP section(s). This reference is to be used when the COLR is used after the activation of TSUP, for the duration of the current operating cycle.

Example of Technical Specification reference:

TECHNICAL SPECIFICATION

REFERENCE:

Technical Specification 3.5.1 l

TSUP TECHNICAL SPECIFICATION: 3.11.A l

i I

l a

l iii l

l Quad Cities Unit 1 Cycle 15 i

Ccra Opercting Limits Rsport MIy,1996 REFERENCES 1.

Commonwealth Edison Company and MidAmerican Energy Company Docket No.

50 254, Quad Cities Station, Unit 1 Facility Operating License, License No. DPR-29, 2.

Letter from D. M. Crutchfield to All Power Reactor Licenses and Applicants, Generic Letter 88-16: Concerning the Removal of Cycle-Specific Parameter Limits from Technical Specifications.

3.

Supplemental Reload Licensing Report for Quad Cities Nuclear Power Station, Unit 1 Reload 14 Cycle 15,24A5182, Revision 0, Class I, December,1995.

4.

Quad Cities Nuclear Power Station, Units 1 and 2, SAFER /GESTR - LOCA Loss-of-Coolant Accident Analysis, NEDC-31345P, Revision 2, Class Ill, July 1989 (as amended).

5.

Extended Operating Domain and Equipment Out-Of-Service (EOD/EOOS) for Quad Cities Nuclear Power Station Units 1 and 2, NEDC-31449, Revision 1, Class 11, April 1992.

6.

GE document GENE-637-037-1193, Class ll, " Analysis of End of Full Power Capability Coastdown with Load Following for Quad Cities 1 and 2, dated November,1993.

7.

NFS letter NFS:BSA:95-054 R. W. Tsai to R. E. Kingston, " Changes to 01C15 OPL-3 Proposed inputs", dated July 31,1995.

8.

NFS letter NFS:BSS:96-023, " Turbine Bypass Valve Profile Change for 01C15 and I

the Effect on the EOD/EOOS Generic Analysis", dated February 9,1996.

9.

NFS Calenote NFSCN:96-006 "O1C15 Kf curve verification", dated February 19.

1996.

l l

l iv Quad Cities Unit 1 Cycle 15

Cera Operating Limits Rrport May,1996 i

LIST OF TABLES I

l I

Table Title Page 1

l 2-1 Maximum Average Planar Linear Heat Generation 2-1 Rate (MAPLHGR) vs. Average Planar Exposure for l

G E 8 B-P8 D OB301 -9 GZ-80 M-4WR-145-T.

1 2-2 Maximum Average Planar Linear Heat Generation 2-2 Rate (MAPLHGR) vs. Average Planar Exposure for l

G E 98-P8 DWB 258-4 G4.0/3 G 3.0-80 M-145-T.

2-3 Maximum Average Planar Linear Heat Generation 2-3 Rate (MAPLHGR) vs. Average Planar Exposure for GE98-P8DWB258-9GZ-80M-145-T.

2-4 Maximum Average Planar Linear Heat Generatiort 2-4 l

Rate (MAPLHGR) vs. Average Planar Expos:ure for GE9B-P8DWB305-7GZ-80M-145-T.

2-5 Maximum Average Planar Linear Heat Generation 25 Rate (MAPLHGR) vs. Average Planar Exposure for

-~

GE10-P8HXB311-8GZ-100Ms-145-T 2-F Maximum Average Planar Linear Heat Generation 2-6 Rate (MAPLHGR) vs. Average Planar Exposure for GE10-P8HXB312-7GZ-100M-145-T l

2-7 Maximum Average Planar Linear Heat Generation 2-7 Rate (MAPLHGR) vs. Average Planar Exposure for l

GE10-P8HXB332-8G5.0-100T-145-T l

2-8 Maximum Average Planar Linear Heat Generation 2-8 Rate (MAPLHGR) vs. Average Planar Exposure for l

G E 10-P8 H X B333-4 G 5.0/6 G4.0- 100T-145-T i

v Quad Cities Unit 1 Cycle 15

Cero Operating Limits Report May,1996 LIST OF FIGURES Figure Title Page 4-1 Kf Factor vs. % Core Flow.

4-1 l

I i

l l

l l

\\

l vi i

i i

I Quad Cities Unit 1 Cycle 15

_.. ~

Core Operating Limits Raport May,1996 1.0 CONTROL ROD WITHDRAWAL BLOCK INSTRUMENTATION (3.2/4.2) 1.1.

TECHNICAL SPECIFICATION

REFERENCE:

Technical Specification Table 3.2-3 and 3.6.H.3.d TSUP TECHNICAL SPECIFICATION:

Table 3.2.E-1 (COLR 1.21,3.6.A.1.c [COLR 1.31

1.2. DESCRIPTION

i The Rod Withdrawal Block Monitor Upscale Instrumentation Trip Setpoint for I

two recirculation loop operation is determined from the following relationship:

l 1 (0.65)Wd + 43% "

1.3. DESCRIPTION

The Rod Withdrawal Block Monitor Upscale Instrument Trip Setpoint for Single Recirculation Loop Operation (SLO) is determined from the following relationship.

I s (0.65)Wd + 39% *

  • l
  • Clamped, wit' an allowable value not to exceed the allowable value for recirculation loop orive flow (Wd) of 100%.

Wd is the percent of drive flow required to produce a rated core flow of 98 million Ib/hr. Trip level setting is in percent of rated power (2511 MWth).

(

Page 1 I

Quad Cities Unit 1 Cycle 15

1. -

. ~ - - _.. - -

i Cera Operating Limits Rrp:rt May,1996 j

l 2.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) (3.5/4.5) j 2.1 TECHNICAL SPECIFICATION

REFERENCE:

Technical Specification 3.5.1 j

TSUP TECHNICAL SPECIFICATION: 3.11.Al

]

2.2 DESCRIPTION

The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) 4 versus Average Planar Exposure for.GE88-P8DOB301-9GZ-80M-4WR-1 145-T is determined from Table 2-1.

i The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR)

I versus Average Planar Exposure for GE9B-P8DWB258-4G4.0/3G3.0-80M-145-T is determined from Table 2-2.

The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR)

I versus Average Planar Exposure for GE9B-P8DWB258-9GZ-80M-145-T is determined from Table 2-3.

The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) versus Average Planar Exposure for GE98-P8DWB305-7GZ-80M-145-T is determined from Table 2-4.

{

The Maximum Average Fianar Linear Heat Generation Rates (MAPLHGR) l versus Average Planar Exposure for GE10-P8HXB311-8GZ-100M-145-T is determined from Table 2-5.

The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) versus Average Planar Exposure for GE10-P8HXB312-7GZ-100M-145-T is determined from Table 2-6.

The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) versus Average Planar Exposure for GE10-P8HXB332-8G5.0-100T-145-T is determined from Table 2-7.

The Maximum Average Planar Linear Heat Generation Rates (MAPLHGR) i versus Average Planar Exposure for GE10-P8HXB333-4G5.0/6G4.0-100T-145-T is determined from Table 2-8.

l 2.3 SINGLE LOOP OPERATION MULTIPLIER j

The tabulated values are multiplied by 0.85 whenever Quad Cities snters Single Loop Operation.

1 k

Page 2 Quad Cities Unit 1 Cycle 15

Ccra Operating Limits Rsport May,1996 TABLE 2-1 MAPLHGR vs. AVERAGE PLANAR EXPOSURE I

FOR BUNDLE TYPE GE8B-P8DOB301-9GZ-80M 4WR-145-T i

LATTICE 565 : P8 DOLO 71-NOG 80M-T LATTICE 854 : P8 DOL 320-6G2.0-80M-T LATTICE 855': P8 DOL 320-3G3.0/6G2.0-80M-T LATTICE 856 : P8 DOLO 71-9GE-80M-T AVERAGE MAPLHGR LIMITS (KW/FT)

PLANAR EXPOSURE 565 854 855 856 I

(GWd/ST) 0.0 11.57 12.18 11.41 11.57 0.2 11.50 12.23 11.49 11.50 1.0 11.30 12.34 11.63 11.30 2.0 11.28 12.60 11.94 11.28 3.0 11.33 12.89 12.34 11.33 i

4.0 11.40 13.01 12.61 11.40 5.0 11.48 13.14 12.82 11.48 6.0 11.55 13.24 13.02 11.55 7.0 11.61 13.31 13.18 11.61 8.0 11.66 13.34 13.28 11.66 9.0 11.69 13.35 13.34 11.69 10.0 11.72 13.35 13.37 11.72 12.5 11.44 13.33 13.31 11.44 15.0 11.07 12.95 12.94 11.07 20.0 10.29 12.23 12.21 10.29 l

25.0 9.50 11.50 11.48 9.50 35.0 7.93 10.13 10.11 7.93 45.0 8.52 8.'48 50.0 6.27 6.21 Page 2-1 l

t 1

Quad Cities Unit 1 Cycle 15

Cora Opercting Limits RIptrt May,1996 i

TABLE 2-2 l

MAPLHGR vs. AVERAGE PLANAR EXPOSURE FOR BUNDLE TYPE GE98-P8DW8258 4G4.0/3G3.0-80M-145-T LATTICE 731 : P8DWLO71-NOG-80M-T LATTICE 1002 : P8DWL278-4G4.0/3G3.0-80M-T LATTICE 1003 : P8DWL290-4G4.0/3G3.0-80M-T l

LATTICE 1004 : P8DWLO71-7GE-80M-T l-AVERAGE MAPLHGR LIMITS (KW/FT)

PLANAR EXPOSURE 731 1002 1003 1004 l

(GWd/ST) 0.0 11.64 12.02 11.23 11.64 0.2 11.57 12.09 11.30 11.57 l

1.0 11.33 12.25 11.47 11.38 l

2.0 11.36 12.46 11.69 11.36 3.0 11.41 12.66 11.98 11.41 4.0 11.49 12.86 12.20 11.49 5.0 11.56 13.07 12.40 11.56 6.0 11.63 13.20 12.54 11.63 7.0 11.69 13.30 12.69 11.69 8.0 11.74 13.40 12.84 11.74 9.0 11.78 13.46 12.97 11.78 l

10.0 11.81 13.50 13.06 11.81 12.5 11.54 13.44 13.04 11.54 15.0 11.16 13.07 12.79 11.16 20.0 10.37 12.34 12.29 10.37 25.0 9.58 11.66 11.75 9.58 35.0 8.01 10.34 10.24 8.01 43.7 4.71 4.71 45.0 8.33 8.15 50.9 5.10 52.4 4.90 Page 2-2 1

l Quad Cities Unit 1 Cycle 15

Core Operating Limits Report May,1996 t

TABLE 2 3 MAPLHGR vs. AVERAGE PLANAR EXPOSURE FOR BUNDLE TYPE GE98 P8DWB258 9GZ-80M 145-T l

LATTICE 731 : P8DWLO71-NOG-80M-T LATTICE 1005 : P8DWL277-7G3.0-80M-T l

LATTICE 1006 : P8DWL288-7G3.0-80M-T l

LATTICE 1007 : P8DWL288-2G4.0/7G3.0-80M-T l

LATTICE 1008 : P8DWLO71-9GE-80M-T l-AVERAGE MAPLHGR LIMITS (KW/FT)

PLANAR EXPOSURE 731 1005 1006 1007 1008 l

(GWd/ST) l 0.0 11.64 12.07 11.27 10.75 11.64 O.2 11.57 12.14 11.35 10.85 11.57 1.0 11.38 12.33 11.55 11.04 11.38 2.0 11.36 12.56 11.80 11.33 11.36 3.0 11.41 12.79 12.10 11.70 11.41 4.0 11.49 13.03 12.31 11.99 11.49 5.0 11.56 13.23 12.53 12.25 11.56 6.0 11.63 13.33 12.71 12.47 11.63 7.0 11.69 13.41 12.84 12.67 11.69 8.0 11.74 13.45 12.94 12.86 11.74 9.0 11.78 13.47 13.00 12.99 11.78 10.0 11.81 13.47 13.05 13.08 11.81 12.5 11.54 13.41 13.02 13.03 11.54 l

l 15.0 11.16 13.04 12.77 12.78 11.16 i

20.0 10.37 12.32 12.27 12.28 10.37 l

25.0 9.58 11.64 11.73 11.73 9.58 l

35.0 8.01 10.32 10.23 10.20 8.01 43.7 4.71 4.71 45.0 8.33 8.15 8.12 50.7 5.12 50.9 5.09 52.4 4.89 Page 2-3 s

Quad Cities Unit 1 Cycle 15

Core Operating Limits Rsport i

May,1996 TABLE 2 4 i

MAPLHGR vs. AVERAGE PLANAR EXPOSURE j

FOR BUNDLE TYPE GE98-P8DWB305-7GZ-80M-145-T i

LATTICE 731 : P8DWLO71-NOG 80M-T LATTICE 1516 : P8DWL339-3G4.0/4G3.0-80M-T i

LATTICE 1517 : P8DWL339-7G3.0-80M-T LATTICE 1518 : P8DWL324-7G3.0-80M-T j

LATTICE 1061 : P8DWLO71-7GE1-80M-T l

AVERAGE MAPLHGR LIMITS (KW/FT)

PLANAR EXPOSURE 731 1516 1517 1518 1061 3*

(GWD/ST) 0.0 11.64 12.00 12.00 11.97 11.64 O.2 11.57 12.10 12.11 12.04 11.57 4

1.0 11.38 12.26 12.27 12.11-11.38 2.0 11.36 12.42 12.44 12.31 11.36 3.0 11.41 12.59 12.60 12.59 11.41 i

4.0 11.49 12.74 12.75 12.91 11.49 4

I 5.0 11.56 12.88 12.89 13.09 11.56 i

6.0 11.63 13.01 13.01 13.23 11.63 I

7.0 11.69 13.10 13.06 13.36 11.69

)

8.0 11.74 13.13 13.09 13.48 11.74 9.0 11.78 13.15 13.12 13.54 11.78 10.0 11.81 13.16 13.15 13.56-11.81 li 12.5 11.54 13.07 13.08 13.52 11.54 15.0 11.16 12.72 12.73 13.12 11.16

[

20.0 10.37 12.04 12.05 12.35 10.37 j

25.0 9.58 11.39 11.40 11.60 9.58 35.0 8.01' 10.15 10.15 10.19 8.01 j

43.7 4.71 4.71 j

45.0 8.69 8.69 8.68 50.7 5.90 50.7 5.89 51.2 5.78 i

Page 2-4 Quad Cities Unit 1 Cycle 15

i.

Core Operating Limits Rrport j.*

May,1996 j

TABLE 2-5 j

MAPLHGR vs. AVERAGE PLANAR EXPOSURE FOR BUNDLE TYPE GE10-P8HXB311-8GZ-100M-145-T 4

4 LATTICE 1807 : P8HXLO71-8GE-100M-T LATTICE 1806 : P8HXL335-8G3.0-100M-T j

LATTICE 1805 : P8HXL353-2G4.0/6G3.0-100M-T LATTICE 1804 : P8HXL335-4G4.0/4G3.0-100M-T LATTICE 1054 : P8HXLO71-NOG-100M-T 1

AVERAGE MAPLHGR LIMITS (KW/FT)

PLANAR EXPOSURE 1054 1806 1805 1804 1807 (GWD/ST) j O.0 11.85 12.06 11.10 12.02 11.85 0.2 11.78 12.12 11.14 12.08 11.78 1

1.0 11.59 12.28 11.27 12.22 11.59 i

2.0 11.57 12.48 11.51 12.40 11.57 3.0 11.61 12.68 11.81 12.57 11.61 4.0 11.68 12.89 12.14 12.76 11.68 5.0 11.75 13.11 12.50 12.94 11.75 6.0 11.81 13.29 12.88 13.12 11.81 7.0 11.86 13.41 13.19 13.28 11.86 8.0 11.91 13.47 13.28 13.40 11.91 9.0 11.94 13.48 13.34 13.46 11.94 10.0 11.97 13.46 13.39 13.49 11.97 12.5 11.75 13.34 13.44 13.33 11.75 15.0 11.38 12.96 13.09 12.95 11.38 20.0 10.59 12.22 12.40 12.22 10.59 25.0 9.81 11.51 11.73 11.50 9.81 35.0 8.26 10.13 10.39 10.13 8.26 44.9 4.93 4.93 45.0 8.55 9.00 8.55 50.4 5.85 50.5 5.85 51.5 5.86 Page 2-5 Quad Cities Unit 1 Cycle 15

.. ~ -

Cero Operating Limits Rsport May,1996 TABLE 2-6 MAPLHGR vs. AVERAGE PLANAR EXPOSURE FOR BUNDLE TYPE GE10-P8HXB312-7GZ-100M-145-T i

l LATTICE 1811 : P8HXLO71-7GE-100M-T l

LATTICE 1810 : P8HXL336-7G3.0-100M-T l

LATTICE 1809 : P8HXL355-1G4.0/6G3.0-100M-T LATTICE 1808 : P8HXL336-3G4.0/4G3.0-100M-T LATTICE 1054 : P8HXLO71-NOG-100M-T l

AVERAGE MAPLHGR LIMITS (KW/FT)

PLANAR

]

l EXPOSURE 1054 1810 1809 1808 1811 (GWD/ST) 1 0.0 11.85 12.04 11.27 12.01 11.85 0.2 11.78 12.11 11.31 12.08 11.78 1.0 11.59 12.27 11.42 12.23 11.59 l

2.0 11.57 12.49 11.65 12.43 11.57 3.0 11.61 12.72 11.93 12.65 11.61 4.0 11.68 12.96 12.24 12.88 11.68 5.0 11.75 13.15 12.58 13.09 11.75 6.0 11.81 13.30 12.94 13.22 11.81 7.0 11.86 13.41 13.15 13.32 11.86 8.0 11.91 13.46 13.32 13.40 11.91 9.0 11.94 13.47 13.43 13.45 11.94 10.0 11.97 13.45 13.50 13.47 11.97 12.5 11.75 13.35 13.45 13.35 11.75 15.0 11.38 12.97 13.10 12.97 11.38 20.0 10.59 12.24 12.41 12.23 10.59 25.0 9.81 11.52 11.74 11.51 9.81 35.0 e.26 10.15 10.41 10.14 8.26 44.9 4.93 4.93 45.0 8.60 9.01 8.61 50.5 5.85 50.6 5.85 51.6 5.86 Page 2-6 Quad Cities Unit 1 Cycle 15

Core Operating Limits Rrport May,1996 TABLE 2-7 MAPLHOR vs. AVERAGE PLANAR EXPOSURE FOR BUNDLE TYPE GE10-P8HX8332 8G5.0-100T-145 T LATTICE 1054 : P8Ht.071-NOG-100T-T LATTICE 2080 : P8HXL358-8G5.0-100T-T LATTICE 2081 : P8HXL377 8G5.0-100T-T LATTICE 2082 : P8HXLO71-8GE-100T-T l

l

~

AVERAGE MAPLHGR LIMITS (KW/FT) l PLANAR EXPOSURE 1054 2080 2081 2082 (GWD/ST) 0.0 11.85 11.98 11.55 11.85 0.2 11.78 12.05 11.58 11.78 1.0 11.59 12.18 11.65 11.59 2.0 11.57 12.33 11.80 11.57 1

3.0 11.61

'12.48 11.97 11.61 l

4.0 11.68 12.57 12.11 11.68 5.0 11.75 12.67 12.25 11.75 6.0 11.81 12.77 12.38 11.81 l

7.0 11.86 12.88 12.47 11.86 8.0 11.91 12.85 12.57 11.91 9.0 11.94 12.83 12.67 11.94 10.0 11.97 12.84 12.77 11.97 12.5 11.75 13.05 12.92 11.75 15.0 11.38 12.89 12.77 11.38 20.0 10.59 12.17 12.24 10.59 25.0 9.81 11.46 11.50 9.81 35.0 8.26 10.09 10.08 8.26 4.93 44.9 4.93 8.82 8.51 45.0 5.80 50.5 5.78 51.4 1

l Page 2-7 t

Quad Cities Unit 1 Cycle 15

1 4

Cora Opersting Limits R: port May,1996 TABLE 2-8 MAPLHGR vs. AVERAGE PLANAR EXPOSURE FOR BUNDLE TYPE GE10-P8HXB333-405.0/6G4.0-100T-145-T LATTICE 1054 : P8HXLO71-NOG-100T-T LATTICE 2077 : P8HXL358-4G5.0/6G4.0-100T-T LATTICE 2078 : P8HXL377-4G5.0/6G4.0-100T-T LATTICE 2079 : P8HXLO71-10GE-100T-T AVERAGE MAPLHGR LIMITS (KW/FT)

PLANAR EXPOSURE 1054 2077 2078 2079 (GWD/ST) 0.0 11.85 11.81 11.22 11.85 0.2 11.78 11.86 11.26 11.78 1.0 11.59 11.95 11.36 11.59 2.0 11.57 12.11 11.52 11.57 3.0 11.61 12.25 11.69 11.61 4.0 11.68 12.40 11.88 11.68 5.0 11.75 12.56 12.08 11.75 6.0 11.81 12.72 12.29 11.81 7.0 11.86 12.85 12.46 11.86 8.0 11.91 12.89 12.61 11.91 9.0 11.94 12.94 12.76 11.94 10.0 11.97 13.00 12.90 11.97 12.5 11.75 13.14 13.02 11.75 15.0 11.38 12.90 12.79 11.38 20.0 10.59 12.17 12.24 10.59 25.0 9.81 11.46 11.50 9.81 35.0 8.26 10.08 10.08 8.26 44.9 4.93 4.93 45.0 8.81 8.47 50.4 5.81 51.4

'5.77 i

i l

i

]

Page 2-8 4

i Quad Cities Unit 1 Cycle 15

Core Operating Limits Rnport May,1996 3.0 LINEAR HEAT GENERATION RATE (LHGR) (3.5/4.5)

I 3.1 TECHNICAL SPECIFICATION

REFERENCE:

l Technical Specification 3.5.J l

TSUP TECHNICAL SPECIFICATION: 3.11.Dl 1

l

3.2 DESCRIPTION

A.

The LHGR limit is 14.4 Kw/ft for all fuel types in the 01C15 core:

i 1.

GE88-P8DOB301-9GZ-80M-4WR-145-T

}

2.

G E 9 B-P8 DWB 258-4G 4.0/3 G 3.0-80M-145-T 3.

GE9B-P8DWB258 9GZ-80M-145-T i

4.

GE98-P8DWB305-7GZ-80M-145-T 5.

GE10-P8HXB311-8GZ-100M-145-T l

6.

GE10 P8HXB312-7GZ-100M-145-T 7.

GE10 P8HXB332-8G5.0-100T-145-T l

8.

G E 10-P8 HX B 333-4 G 5.0/6 G4.0 100T-145-T

.;~.

3

~

i j

l 1

i 4

i Page 3 Quad Cities Unit 1 Cycle 15

Ccre Operating Limits Rsport May,1996 4.0 MINIMUM CRITICAL POWER RATIO IMCPR) (3.5/4.5) 4.1 TECHNICAL SPECIFICATION

REFERENCE:

Technical Specifications 3.5.K,3.6.H.3,3.3.L TSUP TECHNICAL SPECIFICATION: 3.11.C,3.3.E l

4.2 DESCRIPTION

)

i During steady-state operation at rated core flow, the Operating Limit MCPR (OLMCPR) shall be greater than or equal to:

1.32 for tave s 0.68 seconds (0.556)tave +0.942 for 0.681 tave 10.86 seconds where tave = mean 20% scram insertion time for all surveillance data from Technical Specification 4.3.C which has been generated in the current cycle.

For core flows other than rated, these nominal values of OLMCPR shall be increased by a factor of Kf where Kf is as shown in Figure 4-1.

The (tau-ave dependent) OLMCPR limit stated above is valid for all planned Operational modes, including increased Core Flow (ICF) and Final Feedwater Temperature Reduction (FFTR). The value corresponds to the cycle specific determination of the bounding event. For Unit 1 Cycle 15 this event is the Feedwater Controller Failure (FWCF), with the above Operational modes incorporated This value was determined to be 1.32 for the minimum tau-ave of

.68 seconds. This limit matches the cycle independent limit from the Quad Cities Equipment Out-Of-Service / Extended Operating Domain analysis.

- 01C15 has been approved for operating up to 15% (Reference 6) above equilibrium coastdown power level with multiple control rods inserted. At End of Full Power Capability (EFPC) a generic MCPR operating limit MCPR penalty of 0.06 must be added to the operating limit MCPR in order to exceed equilibrium coastdown power.

Page 4 Quad Cities Unit 1 Cycle 15

Core Operating Limits Reptrt l

Mzy,1996 5.0 ANALYTICAL METHODS j

The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC in the latest approved revision or supplement of the topical reports describing the methodclogy. For Quad Cities Unit i

1, the topical reports are:

(1)

NEDE-24011-P-A " General Electric Standard Application for Reactor Fuel,"

(latest approved revision).

I (2)

Commonwealth Edison Topical Report NFSR-OO85, " Benchmark of BWR Nuclear Design Methods," (latest approved revision).

(3)

Commonwealth Edison Topical Report NFSR-0085, Supplement 1, Quad l

Cities Gamma Scan Comparisons," (latest approved revision).

}

(4)

Commonwealth Edison Topical Report NFSR-OO85, Supplement 2, Design Methods - Neutronics Licensing Analyses," (latest approved revision).

t l

l i

1 t

l i

Page 5 Quad Cities Unit 1 Cycle 15

l

~

FIGURE 4-1 l

Kf FACTOR 1.5 l

- s l

's 's k......

x

\\

' ' ~ ~.

Automatic Flow Control 32 1.2


N

- - - - - _~

i s__

N N

N 1.1

--- _ ~ ~ -

N Manual Flow Control N

's-N s._

1

- - --(-

-- -07%---Ma- --x Flo-- -)--

N w

0.9 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100105

% Core Flow Quad Cities Unit 1 Cycle 15 May,1996 Core Operating Limits Report Page 4-1

- -