MONTHYEARML20210L5231999-08-0505 August 1999 Summary of 990708-09 Meeting with Detroit Edison Co in Rockville,Md Re Issues Related to Fermi 2 Submittal for Conversion of Current TSs to Improved Standard Tss.List of Participants & RAI Tracking Numbers Encl ML20209E7641999-07-0707 July 1999 Summary of 990617 Meeting with Licensee Re Util Plans to Add Racks to & Replace Older Racks in Sfp.List of Attendees Encl ML20206A3111999-04-16016 April 1999 Summary of 990412-13 Meeting with Detroit Edison Co Re Issues Related to Fermi 2 Submittal for Conversion to Improved Std Ts.List of Meeting Participants,Revised Conversion Schedule & List of Beyond Scope Issues Encl ML20205Q7481999-04-14014 April 1999 Summary of 990319 Meeting W/Util & Excel,Inc in Rockville,Md Re Improved STS Conversion.Attendee List,Request for Addl Info & Viewgraphs Encl ML20202H9211999-01-26026 January 1999 Summary of 990111-12 Meetings with Util at NRC Headquarters to Discuss Issues Related to Fermi 2 Submittal for Conversion to Improved Sts.List of Questions for Sections 3.5 & 3.6 & Meeting Participants Encl ML20198J6911998-12-23023 December 1998 Summary of 981201-04 Meetings with Util in Rockville,Md Re Improved STS Conversion ML20196F6001998-11-20020 November 1998 Summary of 981109-10 Meeting with Util Re Issues Related to Fermi Unit 2 Submittal for Conversion to Improved Std Tss. Primary Focus Was to Discuss Proposed Questions for RAI for Sections 3.4,3.7 & 3.9 of Conversion.Meeting Attendees Encl ML20155A8741998-10-26026 October 1998 Summary of 980928,29,30,1007 & 08 Meetings with Detroit Edison Co to Discuss Plant Improved Std TSs Conversion. List of Participants Encl ML20153G4541998-09-21021 September 1998 Summary of 980908-09 Meeting W/Detroit Edison Co in Rockville,Md Re Fermi 2 Submittal for Conversion to Improved Standard Tss.List of Attendees Encl ML20238F2261998-08-27027 August 1998 Summary of 980805-06 Meeting with Detroit Edison Co in Rockville,Md Re Issues Related to Fermi 2 Submittal for Conversion to Improved Standard TS ML20237C5751998-08-20020 August 1998 Summary of 980728-29 Meeting W/De in Rockville,Md Re Issues Related to Fermi 2 Submittal for Conversion to Improved TS W/Primary Focus on Review of Section 3.6.List of Meeting Participants Encl ML20236S0791998-07-14014 July 1998 Summary of 980707 & 08 Meeting W/Util at NRC Headquarters Re Issues Related to Plant,Unit 2 Submittal for Conversion to Improved Std Tss.Primary Focus of Meeting Was Review of Section 3.4 of Std Ts.List of Meeting Participants Encl ML20197B6751998-03-0505 March 1998 Summary of 980220 Telcon Re Quality of Licensing Submittals for Plant Unit 2.Submittals for Discussion & Participants in Call Listed in Encl ML20203D9551998-02-12012 February 1998 Summary of 980130 Meeting W/Util Re General Status of Plant & Status of Selected Licensing Issues.List of Attendees Encl ML20199G6801997-11-19019 November 1997 Summary of 971104 Meeting W/Util Re Issues Related to Improved STS for Fermi 2.List of Meeting Attendees Encl ML20140H8481997-05-0505 May 1997 Summary of 970422 Meeting W/Licensee at NRC Headquarters Re Issues Related to EECW Sys at Plant ML20133A4881996-12-23023 December 1996 Summary of 961218 Meeting W/Util in NRC Headquarters Re State of Licensee Corrective Action Program,Performance of Operations & Sys Engineering Personnel & Activities Re Control of Plants Design Basis.List of Attendees Encl ML20135B4411996-11-21021 November 1996 Summary of 960927 Meeting W/Util Re Status of Plans to Decommission Fermi 1 Facility.Concern Areas & Resulting Discussions,Listed.Decommissioning Project Plan,Encl ML20059J1471994-01-10010 January 1994 Summary of Operating Reactors Events Briefing 94-01 Conducted on 940105 to Inform Senior Managers of Listed Ofcs of Selected Events That Occurred Since Last Briefing on 931222.Attendees Listed in Encl 1 ML20057G3571993-10-15015 October 1993 Summary of 930913 Meeting W/Util in Rockville,Md Re Concerns W/Thermal Binding & Pressure Locking of Gate Valves.List of Meeting Attendees & Handout Matls Encl ML20058M5891993-09-27027 September 1993 Summary of Operating Reactors Events Meeting 93-36 on 930922 ML20149D6051993-09-15015 September 1993 Summary of 930708 Region III Annual Training Managers Conference in Glen Ellyn,Il.Purpose of Meeting to Provide Forum for Discussion on Rev 7 of Operator Licensing Examiner Stds & to Discuss Operator Licensing Issues ML20057E6271993-09-13013 September 1993 Summary of Operating Reactors Events Meeting 93-34 on 930908 ML20056D7151993-05-21021 May 1993 Summary of 930428 Periodic Mgt Meeting in Rockville,Md to Discuss Recent Independent Verification Program at Facility. Attendees Listed in Encl ML20195B2211988-06-0808 June 1988 Summary of Operating Reactors Events Meeting 88-23 on 880607.List of Attendees,Events Discussed & Summary of Reactor Scrams Encl ML20151K7361988-04-15015 April 1988 Summary of Operating Reactors Events Meeting 88-15 on 880412.List of Attendees & Viewgraphs Encl ML20148H6621988-01-15015 January 1988 Summary of Operating Reactors Events Meeting 88-02 on 880112 Re Events Which Occurred Since Last Meeting on 880105.List of Attendees,Significant Elements of Events & Tabulation of long-term Followup Assignments to Be Completed Encl ML20236J7051987-07-29029 July 1987 Summary of 870707 Operating Reactors Events Meeting 87-21 W/ Nrr,Aeod,Res & Regional Ofcs Re Events Occurring Since 870630 Meeting.List of Attendees,Discussion of Events & Summary of Reactor Scrams Also Encl ML20214H5371987-05-20020 May 1987 Summary of 870429 Meeting W/Util to Discuss Environ Info Needed to Support Proposed License Extension.Util Agreed to Provide Environ Info by 870731.List of Attendees Encl ML20205M9901987-03-27027 March 1987 Summary of 870304 Meeting W/Util Re Plant SPDS Isolation Device Design.List of Attendees Encl ML20209J1381987-01-14014 January 1987 Summary of 861211 Meeting W/Util Re Failures of Main Steam Turbine Bypass Flow Line & Corrective Actions Taken by Licensee to Rectify Problems.Agenda,Slide Presentation & Attendance List Encl ML20210T5691987-01-14014 January 1987 Summary of 861211 Meeting W/Util Re Failures Experienced W/ Main Steam Turbine Bypass Flow Line & Corrective Actions to Resolve Problem.Meeting Agenda,Viewgraphs & List of Attendees Encl ML20207L7681987-01-0808 January 1987 Summary of 860908 Meeting W/Util at Facility Re Testing of Recently Installed Alternate Shutdown Panel.Attendee List Encl ML20212D8361986-12-19019 December 1986 Summary of 861210 Meeting W/Util in Bethesda,Md Re Plant Emergency Diesel Generator Unresolved Matters.Detailed Description of Diesel Engine Design,Bearing Problems & Corrective Actions Presented.Meeting Matls Encl ML20215C9961986-12-11011 December 1986 Summary of Operating Reactor Events Meeting 86-41 on 861124.List of Attendees,Events Discussed & Significant Event Elements & Summary of Events That Will Be Input to NRC Performance Indicator Program Encl IA-86-855, Summary of 860909 Meeting W/Utils Re Improving Lines of Communication Between NRC & Licensees,Including Sholly Process,Interpretation of 10CFR50.59,Tech Spec Improvement Program & Discretionary Enforcement.Related Info Encl1986-11-18018 November 1986 Summary of 860909 Meeting W/Utils Re Improving Lines of Communication Between NRC & Licensees,Including Sholly Process,Interpretation of 10CFR50.59,Tech Spec Improvement Program & Discretionary Enforcement.Related Info Encl ML20207L9571986-11-18018 November 1986 Summary of 860909 Meeting W/Utils Re Improving Lines of Communication Between NRC & Licensees,Including Sholly Process,Interpretation of 10CFR50.59,Tech Spec Improvement Program & Discretionary Enforcement.Related Info Encl ML20213F0641986-11-10010 November 1986 Summary of Operating Reactors Events Meeting 86-36 on 861020.List of Attendees,Events Discussed,Significant Events Data Sheet,Summary of Scrams W/Complications & Status of Previous & New Assignments Encl ML20215G0561986-10-0707 October 1986 Summary of 860911 Meeting W/Bwr Owners Group in Bethesda,Md Re Strawman Generic Requirements for Enhancing BWR Containment Performance in Severe Accident Conditions.Second Technical Exchange Meeting in mid-Nov 1986 Proposed ML20212N6801986-08-27027 August 1986 Summary of Operating Reactor Events Meeting 86-30 on 860825 to Discuss Events Which Occurred Since Last Meeting on 860818 ML20205G9551986-08-13013 August 1986 Summary of Operating Reactors Events Meeting 86-28 on 860811 Re Briefing of Ofc Director,Div Directors & Representatives on Events Discussed at 860804 Meeting.List of Attendees & Viewgraphs Encl ML20206L9081986-08-11011 August 1986 Summary of Operating Reactor Events Meeting 86-27 on 860804 W/Ofc Director,Div Directors & Representatives Re Briefing on Events Which Occurred Since Last Meeting on 860728.List of Attendees & Viewgraphs Encl ML20202G1711986-07-0808 July 1986 Summary of Operating Reactor Events Meeting 86-22 on 860630 W/Ofc Director,Div Directors & Representatives to Discuss Events Occurring Since 860623.List of Attendees & Viewgraphs Encl ML20205Q4811986-04-14014 April 1986 Summary of ACRS Reactor Operations Subcommittee 860212 Meeting in Washington,Dc Re Operation Events & 50-54(f) Improvement Program at Fermi ML20210J0261986-03-24024 March 1986 Summary of Operating Reactor Events Meeting 86-08 on 860317 to Discuss Events Occurring Since Last Meeting on 860310 ML20141N6911986-03-0707 March 1986 Trip Rept of 860227-28 Site Visit to Observe Fairbanks Morse Upper Crankshaft Main Bearings.Bearings from Engine 11 & 13 Looked Acceptable,But Showed Scratched Areas.Engine 12 & 14 Bearings Not Observed ML20141N6831986-03-0707 March 1986 Summary of Operating Reactors Events Meeting 86-05 on 860224.Lists of Attendees,Events & Significant Elements Discussed & Assignment of Followup Review Responsibility Encl ML20151N3021985-12-19019 December 1985 Summary of 851216 Operating Reactor Events Meeting 85-27. Attendance List,Viewgraphs of Events Discussed,Significant Event Elements,Assignment of Followup Review Responsibility & Status of Previous Assignments Encl ML20211L1181985-11-27027 November 1985 Partially Withheld Trip Rept Re Audit of Licensee Administration of Requalification Exams,Including Exam of Licensed Operator on Duty During 850701 incident.NRC- Administered Requalification Exam Scheduled During FY86 ML20138P0081985-10-21021 October 1985 Summary of Operating Reactors Events Meeting 85-19 on 851007 W/Ofc Directors,Div Directors & Representatives on Events Which Occurred Since Last Meeting on 851007 1999-08-05
[Table view] Category:MEETING SUMMARIES-INTERNAL (NON-TRANSCRIPT)
MONTHYEARML20210L5231999-08-0505 August 1999 Summary of 990708-09 Meeting with Detroit Edison Co in Rockville,Md Re Issues Related to Fermi 2 Submittal for Conversion of Current TSs to Improved Standard Tss.List of Participants & RAI Tracking Numbers Encl ML20209E7641999-07-0707 July 1999 Summary of 990617 Meeting with Licensee Re Util Plans to Add Racks to & Replace Older Racks in Sfp.List of Attendees Encl ML20206A3111999-04-16016 April 1999 Summary of 990412-13 Meeting with Detroit Edison Co Re Issues Related to Fermi 2 Submittal for Conversion to Improved Std Ts.List of Meeting Participants,Revised Conversion Schedule & List of Beyond Scope Issues Encl ML20205Q7481999-04-14014 April 1999 Summary of 990319 Meeting W/Util & Excel,Inc in Rockville,Md Re Improved STS Conversion.Attendee List,Request for Addl Info & Viewgraphs Encl ML20202H9211999-01-26026 January 1999 Summary of 990111-12 Meetings with Util at NRC Headquarters to Discuss Issues Related to Fermi 2 Submittal for Conversion to Improved Sts.List of Questions for Sections 3.5 & 3.6 & Meeting Participants Encl ML20198J6911998-12-23023 December 1998 Summary of 981201-04 Meetings with Util in Rockville,Md Re Improved STS Conversion ML20196F6001998-11-20020 November 1998 Summary of 981109-10 Meeting with Util Re Issues Related to Fermi Unit 2 Submittal for Conversion to Improved Std Tss. Primary Focus Was to Discuss Proposed Questions for RAI for Sections 3.4,3.7 & 3.9 of Conversion.Meeting Attendees Encl ML20155A8741998-10-26026 October 1998 Summary of 980928,29,30,1007 & 08 Meetings with Detroit Edison Co to Discuss Plant Improved Std TSs Conversion. List of Participants Encl ML20153G4541998-09-21021 September 1998 Summary of 980908-09 Meeting W/Detroit Edison Co in Rockville,Md Re Fermi 2 Submittal for Conversion to Improved Standard Tss.List of Attendees Encl ML20238F2261998-08-27027 August 1998 Summary of 980805-06 Meeting with Detroit Edison Co in Rockville,Md Re Issues Related to Fermi 2 Submittal for Conversion to Improved Standard TS ML20237C5751998-08-20020 August 1998 Summary of 980728-29 Meeting W/De in Rockville,Md Re Issues Related to Fermi 2 Submittal for Conversion to Improved TS W/Primary Focus on Review of Section 3.6.List of Meeting Participants Encl ML20236S0791998-07-14014 July 1998 Summary of 980707 & 08 Meeting W/Util at NRC Headquarters Re Issues Related to Plant,Unit 2 Submittal for Conversion to Improved Std Tss.Primary Focus of Meeting Was Review of Section 3.4 of Std Ts.List of Meeting Participants Encl ML20197B6751998-03-0505 March 1998 Summary of 980220 Telcon Re Quality of Licensing Submittals for Plant Unit 2.Submittals for Discussion & Participants in Call Listed in Encl ML20203D9551998-02-12012 February 1998 Summary of 980130 Meeting W/Util Re General Status of Plant & Status of Selected Licensing Issues.List of Attendees Encl ML20199G6801997-11-19019 November 1997 Summary of 971104 Meeting W/Util Re Issues Related to Improved STS for Fermi 2.List of Meeting Attendees Encl ML20140H8481997-05-0505 May 1997 Summary of 970422 Meeting W/Licensee at NRC Headquarters Re Issues Related to EECW Sys at Plant ML20133A4881996-12-23023 December 1996 Summary of 961218 Meeting W/Util in NRC Headquarters Re State of Licensee Corrective Action Program,Performance of Operations & Sys Engineering Personnel & Activities Re Control of Plants Design Basis.List of Attendees Encl ML20135B4411996-11-21021 November 1996 Summary of 960927 Meeting W/Util Re Status of Plans to Decommission Fermi 1 Facility.Concern Areas & Resulting Discussions,Listed.Decommissioning Project Plan,Encl ML20059J1471994-01-10010 January 1994 Summary of Operating Reactors Events Briefing 94-01 Conducted on 940105 to Inform Senior Managers of Listed Ofcs of Selected Events That Occurred Since Last Briefing on 931222.Attendees Listed in Encl 1 ML20057G3571993-10-15015 October 1993 Summary of 930913 Meeting W/Util in Rockville,Md Re Concerns W/Thermal Binding & Pressure Locking of Gate Valves.List of Meeting Attendees & Handout Matls Encl ML20058M5891993-09-27027 September 1993 Summary of Operating Reactors Events Meeting 93-36 on 930922 ML20149D6051993-09-15015 September 1993 Summary of 930708 Region III Annual Training Managers Conference in Glen Ellyn,Il.Purpose of Meeting to Provide Forum for Discussion on Rev 7 of Operator Licensing Examiner Stds & to Discuss Operator Licensing Issues ML20057E6271993-09-13013 September 1993 Summary of Operating Reactors Events Meeting 93-34 on 930908 ML20056D7151993-05-21021 May 1993 Summary of 930428 Periodic Mgt Meeting in Rockville,Md to Discuss Recent Independent Verification Program at Facility. Attendees Listed in Encl ML20195B2211988-06-0808 June 1988 Summary of Operating Reactors Events Meeting 88-23 on 880607.List of Attendees,Events Discussed & Summary of Reactor Scrams Encl ML20151K7361988-04-15015 April 1988 Summary of Operating Reactors Events Meeting 88-15 on 880412.List of Attendees & Viewgraphs Encl ML20148H6621988-01-15015 January 1988 Summary of Operating Reactors Events Meeting 88-02 on 880112 Re Events Which Occurred Since Last Meeting on 880105.List of Attendees,Significant Elements of Events & Tabulation of long-term Followup Assignments to Be Completed Encl ML20236J7051987-07-29029 July 1987 Summary of 870707 Operating Reactors Events Meeting 87-21 W/ Nrr,Aeod,Res & Regional Ofcs Re Events Occurring Since 870630 Meeting.List of Attendees,Discussion of Events & Summary of Reactor Scrams Also Encl ML20214H5371987-05-20020 May 1987 Summary of 870429 Meeting W/Util to Discuss Environ Info Needed to Support Proposed License Extension.Util Agreed to Provide Environ Info by 870731.List of Attendees Encl ML20205M9901987-03-27027 March 1987 Summary of 870304 Meeting W/Util Re Plant SPDS Isolation Device Design.List of Attendees Encl ML20210T5691987-01-14014 January 1987 Summary of 861211 Meeting W/Util Re Failures Experienced W/ Main Steam Turbine Bypass Flow Line & Corrective Actions to Resolve Problem.Meeting Agenda,Viewgraphs & List of Attendees Encl ML20209J1381987-01-14014 January 1987 Summary of 861211 Meeting W/Util Re Failures of Main Steam Turbine Bypass Flow Line & Corrective Actions Taken by Licensee to Rectify Problems.Agenda,Slide Presentation & Attendance List Encl ML20207L7681987-01-0808 January 1987 Summary of 860908 Meeting W/Util at Facility Re Testing of Recently Installed Alternate Shutdown Panel.Attendee List Encl ML20212D8361986-12-19019 December 1986 Summary of 861210 Meeting W/Util in Bethesda,Md Re Plant Emergency Diesel Generator Unresolved Matters.Detailed Description of Diesel Engine Design,Bearing Problems & Corrective Actions Presented.Meeting Matls Encl ML20215C9961986-12-11011 December 1986 Summary of Operating Reactor Events Meeting 86-41 on 861124.List of Attendees,Events Discussed & Significant Event Elements & Summary of Events That Will Be Input to NRC Performance Indicator Program Encl IA-86-855, Summary of 860909 Meeting W/Utils Re Improving Lines of Communication Between NRC & Licensees,Including Sholly Process,Interpretation of 10CFR50.59,Tech Spec Improvement Program & Discretionary Enforcement.Related Info Encl1986-11-18018 November 1986 Summary of 860909 Meeting W/Utils Re Improving Lines of Communication Between NRC & Licensees,Including Sholly Process,Interpretation of 10CFR50.59,Tech Spec Improvement Program & Discretionary Enforcement.Related Info Encl ML20207L9571986-11-18018 November 1986 Summary of 860909 Meeting W/Utils Re Improving Lines of Communication Between NRC & Licensees,Including Sholly Process,Interpretation of 10CFR50.59,Tech Spec Improvement Program & Discretionary Enforcement.Related Info Encl ML20213F0641986-11-10010 November 1986 Summary of Operating Reactors Events Meeting 86-36 on 861020.List of Attendees,Events Discussed,Significant Events Data Sheet,Summary of Scrams W/Complications & Status of Previous & New Assignments Encl ML20215G0561986-10-0707 October 1986 Summary of 860911 Meeting W/Bwr Owners Group in Bethesda,Md Re Strawman Generic Requirements for Enhancing BWR Containment Performance in Severe Accident Conditions.Second Technical Exchange Meeting in mid-Nov 1986 Proposed ML20212N6801986-08-27027 August 1986 Summary of Operating Reactor Events Meeting 86-30 on 860825 to Discuss Events Which Occurred Since Last Meeting on 860818 ML20205G9551986-08-13013 August 1986 Summary of Operating Reactors Events Meeting 86-28 on 860811 Re Briefing of Ofc Director,Div Directors & Representatives on Events Discussed at 860804 Meeting.List of Attendees & Viewgraphs Encl ML20206L9081986-08-11011 August 1986 Summary of Operating Reactor Events Meeting 86-27 on 860804 W/Ofc Director,Div Directors & Representatives Re Briefing on Events Which Occurred Since Last Meeting on 860728.List of Attendees & Viewgraphs Encl ML20202G1711986-07-0808 July 1986 Summary of Operating Reactor Events Meeting 86-22 on 860630 W/Ofc Director,Div Directors & Representatives to Discuss Events Occurring Since 860623.List of Attendees & Viewgraphs Encl ML20205Q4811986-04-14014 April 1986 Summary of ACRS Reactor Operations Subcommittee 860212 Meeting in Washington,Dc Re Operation Events & 50-54(f) Improvement Program at Fermi ML20210J0261986-03-24024 March 1986 Summary of Operating Reactor Events Meeting 86-08 on 860317 to Discuss Events Occurring Since Last Meeting on 860310 ML20141N6831986-03-0707 March 1986 Summary of Operating Reactors Events Meeting 86-05 on 860224.Lists of Attendees,Events & Significant Elements Discussed & Assignment of Followup Review Responsibility Encl ML20151N3021985-12-19019 December 1985 Summary of 851216 Operating Reactor Events Meeting 85-27. Attendance List,Viewgraphs of Events Discussed,Significant Event Elements,Assignment of Followup Review Responsibility & Status of Previous Assignments Encl ML20138P0081985-10-21021 October 1985 Summary of Operating Reactors Events Meeting 85-19 on 851007 W/Ofc Directors,Div Directors & Representatives on Events Which Occurred Since Last Meeting on 851007 ML20133F9941985-10-0707 October 1985 Summary of Operating Reactors Events Meeting 85-16 on 850916 Re Briefing of Director,Div Directors & Representatives on Events Occurring Since 850909 Meeting.List of Attendees & Viewgraphs Encl ML20133E4631985-10-0101 October 1985 Summary of Operating Reactors Events Meeting 85-17 on 850923.List of Attendees & Viewgraphs Encl 1999-08-05
[Table view] |
Text
. . - .- -_
e.
4We' 0b
, UNITEO STATES y* * ;, NUCLEAR REGULATORY COMMisslON g g WASHINGTON, D. C. 20555
'*, . . . . ./ JAN 2 91979 Q[
Docket No: 50-341 APPLICANT: Detroit Edison Company FACILITY: Enrico Fermi Atomic Power Plant, Unit 2
SUBJECT:
SUMMARY
OF JANUARY 16, 1979 VISIT TO FERMI 2 PLANT Members of the NRC staff in the Office of Nuclear Reactor Regulation visited the Fenni 2 Plant to observe and discuss safety features as a part of its review of the Detroit Edison Company's application for a license to operate Fermi 2. A list of participants is enc.iosed.
Most of the day was used to tour the plant. A scale model of the reactor, connected piping and components within the drywell, and a cut-away scale model of the drywell, torus and sacrifical shield was very useful in visualizing these components. Regions of the plant that were visited included the control room, the reactor building refueling floor, the torus - both inside and outside - the drywell underneath the reactor vessel, the turbine building operating floor, the natural draft cooling i towers and the residual heat removal (RHR) building, including the roof of the building from which the RHR cooling towers could be seen at close range.
Some aspects of the requests for infonnation transmitted previously from the Reactor Systems Branch and Containment Systems Branch were briefly discussed. In addition, draft requests from the Material Engineering Branch regarding exemptions from the Commission's regulations in Appendices G and H of 10 CFR Part 50 and 10 CFR 50.55 a(g) were briefly mentioned.
The MTEB requests will be transmitted by letter during the week of January 22, 1979. The applicant indicated that responses to outstanding requests on limiting torus water temperature and maximum pennissible emergency service water temperature will be transmitted by February 26, 1979. The applicant will confirm its response to the staff's question that indicated .
the diesel generator exhaust outlets will be protected from tornado -
induced missiles coming from any direction.
'O L. L. Kintner, Project Manager Light Water Reactors Branch No.1 Division of Project Management
Enclosure:
Attendance List cc: 7 9 0 214 0 0 oCo See next page h .
= - _ - _ . .-. . . - . . - - - - - .
R Dr. Wayne H. Jens 'JAN 2 91979
! Dr. Wayne H. Jens. Mr. Jeffrey A. Alson . ,
Assistant Vice President 772 Green Street, Building 4 ,
j Engineering & Construction Ypsilanti, M'chigan 48197 ,*
Detroit Edison Company 2000 Second Avenue Mr. David Hiller Detroit, Michigan 48226 University of Michigan Law School cc: Eugune B. Thomas , Jr. , Esq. Hutchins Hall LeBoeuf, Lamb, Leiby & MacRae Ann Arbor, Michigan 48109 1757 N. Street, N.W.
Washington, D. C. 20036 Mrs. Martha Drake .
230 Fairview !;
Peter A. Marquardt, Esq. Petoskey, Michioan 49770 i Co-Counsel 1 The Detroit Edison Company 2000 Second Avenue Detroit, Michigan 48226 .
Mr. William J. Fahrner Project Manager - Fermi 2
. The Detroit Edison Company N-2000 Second Avenue Detroit, Michigan 48226
- Larry E. Schuerman Licensing Engineer - Fermi 2 / s j Detroit Edison Company j 2000 Second Avenue ,
Detroit Michigan 48226 4 4
Charles Bechhoefer, Esq. , Chairman Atomic Safety & Licensing Board ,
Panel V. S. Nuclear Regulatory Commission Washington, D. C. 20555 i
Dr. David R. Schnik Department of Oceanography Texas A & M University College Station, Texas 77840 i Mr. Frederick J. Shen i Atomic Safety & Licensing Board Panel U. S. Nuclear Regulatory Commission Washington, D. C. 20555 f
i b
- . - - r _ . -
!' e ..
ENCLOSURE 4
' ATTENDANCE LIST ;
JANUARY 16, 1979 VISIT TO FERMI 2 PLANT 5
NRC
Chuck Graves Mel Batch I Larry Bell Larry E. Schuennan i Felix Litton E. Lusis Les Kintner Lawrence Wooden e '
T. Huang Daniel Lehnert 4
I f
I l I 4 t
.a l
l 1
4 t
I i
1 i i
^
l 1
1 4
1