MONTHYEARLIC-99-0098, Forwards Revs to Fort Calhoun Station EPIPs & Emergency Planning Forms Manual.Document Update Instructions & Summary of Changes Are Included on Confirmation of Transmittal Form Attached1999-10-15015 October 1999 Forwards Revs to Fort Calhoun Station EPIPs & Emergency Planning Forms Manual.Document Update Instructions & Summary of Changes Are Included on Confirmation of Transmittal Form Attached ML20217G9261999-10-15015 October 1999 Forwards Insp Rept 50-285/99-10 on 990913-17.One NCV Noted ML20217G2331999-10-14014 October 1999 Forwards Insp Rept 50-285/99-09 on 990913-17.No Violations Noted LIC-99-0091, Submits Suppl Response to GL 99-02, Laboratory Testing of Nuclear-Grade Activated Charcoal, in Response to NRC RAI During 990817 Meeting with Util1999-10-0808 October 1999 Submits Suppl Response to GL 99-02, Laboratory Testing of Nuclear-Grade Activated Charcoal, in Response to NRC RAI During 990817 Meeting with Util LIC-99-0097, Forwards Final RO & SRO License Applications,As Requested in ,Certifying That Training Completed for Six RO Candidates,Three Instant SRO Candidates & One Upgrade SRO Candidate.Without Encls1999-10-0707 October 1999 Forwards Final RO & SRO License Applications,As Requested in ,Certifying That Training Completed for Six RO Candidates,Three Instant SRO Candidates & One Upgrade SRO Candidate.Without Encls ML20217B5111999-10-0606 October 1999 Forwards Amend 193 to License DPR-40 & Safety Evaluation. Amend Revises TS Sections 2.10.4,3.1 & Table 3-3 to Increase Min Required RCS Flow Rate & Change Surveillance require- Ments for RCS Flow Rate ML20216H7231999-09-29029 September 1999 Informs That Util 980325 Response to GL 97-06, Degradation of SG Internals, Provides Reasonable Assurance That Condition of Util SG Internals in Compliance with Current Licensing Bases for Fort Calhoun Station,Unit 1 ML20212L9571999-09-27027 September 1999 Informs That Follow Up Insp for Drill/Exercise Performance Indicator Will Be Conducted During Wk of 991001 LIC-99-0089, Forwards Preliminary License Exam Applications for Six Ros, Three Instant SROs & One Upgrade SRO Candidate,Per Preparation for Ro/Sro Licensing Exams to Be Administered on 991025-29 at Fcs.Without Encl1999-09-24024 September 1999 Forwards Preliminary License Exam Applications for Six Ros, Three Instant SROs & One Upgrade SRO Candidate,Per Preparation for Ro/Sro Licensing Exams to Be Administered on 991025-29 at Fcs.Without Encl LIC-99-0092, Forwards Revised Epips,Including non-proprietary Rev 8 to EPIP-RR-66,rev 3 to EPIP-EOF-24,rev 14 to RERP-Section F,Rev 11 to RERP-Section I,Rev 12 to RERP-Appendix C & RERP & EPIP Indexes.Proprietary Rev 3 to EPIP-EOF-24,pages 1-3,encl1999-09-21021 September 1999 Forwards Revised Epips,Including non-proprietary Rev 8 to EPIP-RR-66,rev 3 to EPIP-EOF-24,rev 14 to RERP-Section F,Rev 11 to RERP-Section I,Rev 12 to RERP-Appendix C & RERP & EPIP Indexes.Proprietary Rev 3 to EPIP-EOF-24,pages 1-3,encl LIC-99-0087, Forwards Response to NRC Administrative Ltr 99-03, Preparation & Scheduling of Operator Licensing Exams1999-09-17017 September 1999 Forwards Response to NRC Administrative Ltr 99-03, Preparation & Scheduling of Operator Licensing Exams LIC-99-0088, Forwards Documentation Associated with SRO License Renewal Application for Cd Darrow.Applicant Has Satisfactorily Completed Applicable FCS Requalification Program.Without Encls1999-09-16016 September 1999 Forwards Documentation Associated with SRO License Renewal Application for Cd Darrow.Applicant Has Satisfactorily Completed Applicable FCS Requalification Program.Without Encls LIC-99-0080, Requests Approval of Attached Rev to QAP Contained in App a of Usar,Revising Commitment Re Qualifications of Personnel Performing Quality Control Insps of Activities Affecting Fire Protection1999-09-16016 September 1999 Requests Approval of Attached Rev to QAP Contained in App a of Usar,Revising Commitment Re Qualifications of Personnel Performing Quality Control Insps of Activities Affecting Fire Protection LIC-99-0085, Forwards Revs 18 & 19 to TDB-VI, COLR for FCS Unit 1,IAW TS 5.9.5.Rev 18 Resulted from Reevaluation of Cycle 18 Setpoints & Rev 19 Resulted from Changes in Cycle 19 Refueling Boron Concentrations & Addition of TS Parameters1999-09-0808 September 1999 Forwards Revs 18 & 19 to TDB-VI, COLR for FCS Unit 1,IAW TS 5.9.5.Rev 18 Resulted from Reevaluation of Cycle 18 Setpoints & Rev 19 Resulted from Changes in Cycle 19 Refueling Boron Concentrations & Addition of TS Parameters IR 05000285/19990081999-09-0707 September 1999 Forwards Insp Rept 50-285/99-08 on 990907-0811.No Violations Noted.Insp Consisted of Exam of Activities Conducted Under License as Relate to Safety & to Compliance with Commission Rules & Regulations & with Conditions of License ML20211P2581999-09-0303 September 1999 Forwards Insp Rept 50-285/99-06 on 990809-12.No Violations Noted.Insp Consisted of Exam of Activities Under License as Related to EP & to Compliance with Commission Rules & Regulations & with Conditions of License LIC-99-0083, Requests Participation in internet-based Y2K Early Warning Sys (Yews),As Noted in NRC Info Notice 99-25.Plant Point of Contact Will Be JW Chase1999-09-0202 September 1999 Requests Participation in internet-based Y2K Early Warning Sys (Yews),As Noted in NRC Info Notice 99-25.Plant Point of Contact Will Be JW Chase ML20211J9231999-09-0202 September 1999 Forwards SE Accepting Licensee 990301 Requests for Relief Re Third 10-year ISI Interval for Plant,Unit 1.Relief Proposed Alternatives to Requirements in ASME B&PV Section XI,1989 Edition,Paragraphs IWA-5242(a) & IWA-5250(a)(2) ML20211L3241999-09-0202 September 1999 Informs That Due to Administrative Error,Page 2-50 of TSs Contained Error on 2.10.2(2) of Amend 192 to License DPR-40 Issued on 990727.Corrected Page Encl LIC-99-0077, Forwards non-proprietary & Proprietary Revised EP Forms, Including FC-EPF Index,Pp 1 Dtd 990805,pp 2 Dtd 990812,rev 11 to FC-EPF-9,rev 12 to FC-EPF-10,rev 9 to FC-EPF-11,rev 2 to FC-EPF-12 & Rev 3 to FC-EPF-38.Proprietary EP Withheld1999-08-27027 August 1999 Forwards non-proprietary & Proprietary Revised EP Forms, Including FC-EPF Index,Pp 1 Dtd 990805,pp 2 Dtd 990812,rev 11 to FC-EPF-9,rev 12 to FC-EPF-10,rev 9 to FC-EPF-11,rev 2 to FC-EPF-12 & Rev 3 to FC-EPF-38.Proprietary EP Withheld ML20211F4491999-08-25025 August 1999 Forwards Ltr from Ja Miller,Dtd 990819,which Notified State of Iowa of Deficiency Identified During 990810,Fort Calhoun Station Biennial Exercise.One Deficiency Identified for Not Adequately Demonstrating Organizational Capability LIC-99-0076, Forwards fitness-for-duty Program Performance Data for Six Month Period from Jan-June 1999,IAW 10CFR26.71(d)1999-08-20020 August 1999 Forwards fitness-for-duty Program Performance Data for Six Month Period from Jan-June 1999,IAW 10CFR26.71(d) LIC-99-0078, Forwards Rev 16C to FCS Site Security Plan,Per Provisions of 10CFR50.54(p).Rev Has Been Determined Not to Degrade Effectiveness of Current Security Plans.List of Changes, Provided.Encl Withheld1999-08-20020 August 1999 Forwards Rev 16C to FCS Site Security Plan,Per Provisions of 10CFR50.54(p).Rev Has Been Determined Not to Degrade Effectiveness of Current Security Plans.List of Changes, Provided.Encl Withheld ML20210R1491999-08-13013 August 1999 Forwards Insp Rept 50-285/99-07 on 990719-23.No Violations Noted.Nrc Identified One Issue Which Was Evaluated Under Risk Significance Determination Process & Was Determined to Be of Low Risk Significance LIC-99-0075, Forwards Monthly Operating Rept for July 1999 for Fcs,Unit 1,per Plant TS 5.9.1.Revised Rept for June 1999,encl Due to Inadvertent Reporting of Gross Electrical Energy Data When Net Electrical Energy Data Was Required1999-08-13013 August 1999 Forwards Monthly Operating Rept for July 1999 for Fcs,Unit 1,per Plant TS 5.9.1.Revised Rept for June 1999,encl Due to Inadvertent Reporting of Gross Electrical Energy Data When Net Electrical Energy Data Was Required ML20211A9501999-08-12012 August 1999 Discusses 990720-21 Workshop Conducted in Region IV Ofc,Re Exchange of Info in Area of Use of Risk Insights in Regulatory Activities.List of Attendees,Summary of Topic & Issues,Agenda & Copies of Handouts Encl ML20211B7881999-08-10010 August 1999 Transmits Summary of Two Meetings with Risk-Informed TS Task Force in Rockville,Md on 990514 & 0714 ML20210N1991999-08-0909 August 1999 Informs That as Result of NRC Review of Licensee Responses to GL 92-01,rev 1,suppl 1 & Suppl 1 Rai,Staff Revised Info in Reactor Vessel Integrity Database & Releasing Database as Rvid Version 2 ML20210P8991999-08-0909 August 1999 Forwards FEMA Final Rept for 990630 Offsite Medical Drill. No Deficiencies or Areas Requiring Corrective Action Identified During Drill LIC-99-0072, Requests That Licensee 990526 Application for Amend & Related Documents,Be Withdrawn.Util Requests That NRC Review Attached Responses to Ensure That Upcoming Submittal Will Be Acceptable1999-08-0606 August 1999 Requests That Licensee 990526 Application for Amend & Related Documents,Be Withdrawn.Util Requests That NRC Review Attached Responses to Ensure That Upcoming Submittal Will Be Acceptable ML20210L1461999-08-0303 August 1999 Informs That NRC Plans to Administer Gfes of Written Operator Licensing Exam on 991006.Requests Submittal of Ltr Identifying Individuals Taking Exam,Personnel Allowed Access to Exams & Mailing Address for Exams LIC-99-0068, Documents OPPD Response to Requested Actions in GL 99-02, Laboratory Testing of Nuclear-Grade Activated Charcoal1999-08-0202 August 1999 Documents OPPD Response to Requested Actions in GL 99-02, Laboratory Testing of Nuclear-Grade Activated Charcoal LIC-99-0040, Forwards Rept of Changes,Tests & Experiments Performed Per 10CFR50.59 & Revs to USAR Other than Those Resulting from 10CFR50.59.Encl Info Covers Period of 981101-9903311999-07-28028 July 1999 Forwards Rept of Changes,Tests & Experiments Performed Per 10CFR50.59 & Revs to USAR Other than Those Resulting from 10CFR50.59.Encl Info Covers Period of 981101-990331 LIC-99-0070, Requests Reinstatement of SRO License Previously Held by K Grant-Leanna (License SOP-43569).Operator Is Current on All requalification-training Topics & Has Completed License Reactivation Program1999-07-28028 July 1999 Requests Reinstatement of SRO License Previously Held by K Grant-Leanna (License SOP-43569).Operator Is Current on All requalification-training Topics & Has Completed License Reactivation Program ML20210G1851999-07-27027 July 1999 Forwards Amend 192 to License DPR-40 & Safety Evaluation. Amend Consists of Changes to TS in Response to 990129 Application LIC-99-0057, Forwards 1999/2000 Statement of Cash Flow from Operations, as Guarantee of Payment of Deferred Premiums for Period of 990630 to 0006301999-07-26026 July 1999 Forwards 1999/2000 Statement of Cash Flow from Operations, as Guarantee of Payment of Deferred Premiums for Period of 990630 to 000630 ML20216D6951999-07-26026 July 1999 Informs That During 990614 Review of Fort Calhoun,Nrc Noted That Drill/Exercise Performance Indicator Has Entered White Band,Which Indicated Level of Licensee Performance That Warranted Increased Regulatory Response LIC-99-0071, Informs That Util Expects to Submit Four Licensing Actions in Each of Fys 2000 & 2001,in Response to Administrative Ltr 99-02, Operating Reactor Licensing Action Estimates1999-07-26026 July 1999 Informs That Util Expects to Submit Four Licensing Actions in Each of Fys 2000 & 2001,in Response to Administrative Ltr 99-02, Operating Reactor Licensing Action Estimates LIC-99-0069, Forwards non-proprietary & Proprietary Epips,Including FC- Epf Index Page & Page 2 ,rev 0 to FC- EPF-42,EPIP Index (Page 1 of 2) & EPIP-OSC-2, Cover & Pages 19 & 20.Proprietary Encls Withheld1999-07-23023 July 1999 Forwards non-proprietary & Proprietary Epips,Including FC- Epf Index Page & Page 2 ,rev 0 to FC- EPF-42,EPIP Index (Page 1 of 2) & EPIP-OSC-2, Cover & Pages 19 & 20.Proprietary Encls Withheld ML20210D9471999-07-22022 July 1999 Forwards Amend 191 to DPR-40 & Safety Evaluation.Amend Authorizes Rev to Licensing Basis as Described in Updated Safety Analysis Rept to Incorporate Mod for Overriding Containment Isolation ML20210C2041999-07-20020 July 1999 Discusses 990715 Mgt Meeting with Midamerican Energy Co Re risk-informed Baseline Insp Program Recently Implemented at Cooper & Fort Calhoun Stations ML20210C0201999-07-20020 July 1999 Informs That Due to Administrative Oversight,Revised TS Bases Provided in to Fort Calhoun Station Were Not Dated.Dated Pages to TS Encl ML20210B0761999-07-19019 July 1999 Forwards Insp Rept 50-285/99-05 on 990601-0710.No Violations Noted ML20209G5351999-07-15015 July 1999 Informs That Staff Incorporated Rev of TS Bases Provided by Licensee Ltr Dtd 980904,into Fort Calhoun Station Tss. Staff Finds Revs to Associated TS Bases to Be Acceptable. Revised Bases Pages Encl ML20209F5741999-07-12012 July 1999 Ack Receipt of Transmitting Exercise Scenario for Upcoming Biennial Offsite Exercise Scheduled 990810.Scenario Reviewed & Acceptable ML20209G5591999-07-0808 July 1999 Forwards Detailed Listing of Staff Concerns with C-E TR NPSD-683,rev 3 & RCS pressure-temperature Limits Rept LIC-99-0066, Forwards Fort Calhoun Performance Indicators Rept for May 19991999-07-0707 July 1999 Forwards Fort Calhoun Performance Indicators Rept for May 1999 LIC-99-0060, Forwards Proprietary & non-proprietary Revs to Fort Calhoun Station Emergency Plan Forms (Epf),Including FC-EPF,FC-EPF-1 & FC-EPF-17.Proprietary Info Withheld1999-07-0101 July 1999 Forwards Proprietary & non-proprietary Revs to Fort Calhoun Station Emergency Plan Forms (Epf),Including FC-EPF,FC-EPF-1 & FC-EPF-17.Proprietary Info Withheld ML20209D8771999-07-0101 July 1999 Summarizes 990630 Public Meeting Conducted in Fort Calhoun, Ne Re Results of Completed Culture Survey,Plant Status, Facility Activities Re New NRC Oversight Process & License Renewal.Licensee Handout & Attendance List Encl LIC-99-0063, Requests Termination of License Held by MR Anderson (License SOP 43812) for Fort Calhoun Station.Anderson Ended Employment Effective 9906241999-07-0101 July 1999 Requests Termination of License Held by MR Anderson (License SOP 43812) for Fort Calhoun Station.Anderson Ended Employment Effective 990624 1999-09-08
[Table view] Category:INCOMING CORRESPONDENCE
MONTHYEARLIC-99-0098, Forwards Revs to Fort Calhoun Station EPIPs & Emergency Planning Forms Manual.Document Update Instructions & Summary of Changes Are Included on Confirmation of Transmittal Form Attached1999-10-15015 October 1999 Forwards Revs to Fort Calhoun Station EPIPs & Emergency Planning Forms Manual.Document Update Instructions & Summary of Changes Are Included on Confirmation of Transmittal Form Attached LIC-99-0091, Submits Suppl Response to GL 99-02, Laboratory Testing of Nuclear-Grade Activated Charcoal, in Response to NRC RAI During 990817 Meeting with Util1999-10-0808 October 1999 Submits Suppl Response to GL 99-02, Laboratory Testing of Nuclear-Grade Activated Charcoal, in Response to NRC RAI During 990817 Meeting with Util LIC-99-0097, Forwards Final RO & SRO License Applications,As Requested in ,Certifying That Training Completed for Six RO Candidates,Three Instant SRO Candidates & One Upgrade SRO Candidate.Without Encls1999-10-0707 October 1999 Forwards Final RO & SRO License Applications,As Requested in ,Certifying That Training Completed for Six RO Candidates,Three Instant SRO Candidates & One Upgrade SRO Candidate.Without Encls LIC-99-0089, Forwards Preliminary License Exam Applications for Six Ros, Three Instant SROs & One Upgrade SRO Candidate,Per Preparation for Ro/Sro Licensing Exams to Be Administered on 991025-29 at Fcs.Without Encl1999-09-24024 September 1999 Forwards Preliminary License Exam Applications for Six Ros, Three Instant SROs & One Upgrade SRO Candidate,Per Preparation for Ro/Sro Licensing Exams to Be Administered on 991025-29 at Fcs.Without Encl LIC-99-0092, Forwards Revised Epips,Including non-proprietary Rev 8 to EPIP-RR-66,rev 3 to EPIP-EOF-24,rev 14 to RERP-Section F,Rev 11 to RERP-Section I,Rev 12 to RERP-Appendix C & RERP & EPIP Indexes.Proprietary Rev 3 to EPIP-EOF-24,pages 1-3,encl1999-09-21021 September 1999 Forwards Revised Epips,Including non-proprietary Rev 8 to EPIP-RR-66,rev 3 to EPIP-EOF-24,rev 14 to RERP-Section F,Rev 11 to RERP-Section I,Rev 12 to RERP-Appendix C & RERP & EPIP Indexes.Proprietary Rev 3 to EPIP-EOF-24,pages 1-3,encl LIC-99-0087, Forwards Response to NRC Administrative Ltr 99-03, Preparation & Scheduling of Operator Licensing Exams1999-09-17017 September 1999 Forwards Response to NRC Administrative Ltr 99-03, Preparation & Scheduling of Operator Licensing Exams LIC-99-0088, Forwards Documentation Associated with SRO License Renewal Application for Cd Darrow.Applicant Has Satisfactorily Completed Applicable FCS Requalification Program.Without Encls1999-09-16016 September 1999 Forwards Documentation Associated with SRO License Renewal Application for Cd Darrow.Applicant Has Satisfactorily Completed Applicable FCS Requalification Program.Without Encls LIC-99-0080, Requests Approval of Attached Rev to QAP Contained in App a of Usar,Revising Commitment Re Qualifications of Personnel Performing Quality Control Insps of Activities Affecting Fire Protection1999-09-16016 September 1999 Requests Approval of Attached Rev to QAP Contained in App a of Usar,Revising Commitment Re Qualifications of Personnel Performing Quality Control Insps of Activities Affecting Fire Protection LIC-99-0085, Forwards Revs 18 & 19 to TDB-VI, COLR for FCS Unit 1,IAW TS 5.9.5.Rev 18 Resulted from Reevaluation of Cycle 18 Setpoints & Rev 19 Resulted from Changes in Cycle 19 Refueling Boron Concentrations & Addition of TS Parameters1999-09-0808 September 1999 Forwards Revs 18 & 19 to TDB-VI, COLR for FCS Unit 1,IAW TS 5.9.5.Rev 18 Resulted from Reevaluation of Cycle 18 Setpoints & Rev 19 Resulted from Changes in Cycle 19 Refueling Boron Concentrations & Addition of TS Parameters LIC-99-0083, Requests Participation in internet-based Y2K Early Warning Sys (Yews),As Noted in NRC Info Notice 99-25.Plant Point of Contact Will Be JW Chase1999-09-0202 September 1999 Requests Participation in internet-based Y2K Early Warning Sys (Yews),As Noted in NRC Info Notice 99-25.Plant Point of Contact Will Be JW Chase LIC-99-0077, Forwards non-proprietary & Proprietary Revised EP Forms, Including FC-EPF Index,Pp 1 Dtd 990805,pp 2 Dtd 990812,rev 11 to FC-EPF-9,rev 12 to FC-EPF-10,rev 9 to FC-EPF-11,rev 2 to FC-EPF-12 & Rev 3 to FC-EPF-38.Proprietary EP Withheld1999-08-27027 August 1999 Forwards non-proprietary & Proprietary Revised EP Forms, Including FC-EPF Index,Pp 1 Dtd 990805,pp 2 Dtd 990812,rev 11 to FC-EPF-9,rev 12 to FC-EPF-10,rev 9 to FC-EPF-11,rev 2 to FC-EPF-12 & Rev 3 to FC-EPF-38.Proprietary EP Withheld LIC-99-0078, Forwards Rev 16C to FCS Site Security Plan,Per Provisions of 10CFR50.54(p).Rev Has Been Determined Not to Degrade Effectiveness of Current Security Plans.List of Changes, Provided.Encl Withheld1999-08-20020 August 1999 Forwards Rev 16C to FCS Site Security Plan,Per Provisions of 10CFR50.54(p).Rev Has Been Determined Not to Degrade Effectiveness of Current Security Plans.List of Changes, Provided.Encl Withheld LIC-99-0076, Forwards fitness-for-duty Program Performance Data for Six Month Period from Jan-June 1999,IAW 10CFR26.71(d)1999-08-20020 August 1999 Forwards fitness-for-duty Program Performance Data for Six Month Period from Jan-June 1999,IAW 10CFR26.71(d) LIC-99-0075, Forwards Monthly Operating Rept for July 1999 for Fcs,Unit 1,per Plant TS 5.9.1.Revised Rept for June 1999,encl Due to Inadvertent Reporting of Gross Electrical Energy Data When Net Electrical Energy Data Was Required1999-08-13013 August 1999 Forwards Monthly Operating Rept for July 1999 for Fcs,Unit 1,per Plant TS 5.9.1.Revised Rept for June 1999,encl Due to Inadvertent Reporting of Gross Electrical Energy Data When Net Electrical Energy Data Was Required LIC-99-0072, Requests That Licensee 990526 Application for Amend & Related Documents,Be Withdrawn.Util Requests That NRC Review Attached Responses to Ensure That Upcoming Submittal Will Be Acceptable1999-08-0606 August 1999 Requests That Licensee 990526 Application for Amend & Related Documents,Be Withdrawn.Util Requests That NRC Review Attached Responses to Ensure That Upcoming Submittal Will Be Acceptable LIC-99-0068, Documents OPPD Response to Requested Actions in GL 99-02, Laboratory Testing of Nuclear-Grade Activated Charcoal1999-08-0202 August 1999 Documents OPPD Response to Requested Actions in GL 99-02, Laboratory Testing of Nuclear-Grade Activated Charcoal LIC-99-0040, Forwards Rept of Changes,Tests & Experiments Performed Per 10CFR50.59 & Revs to USAR Other than Those Resulting from 10CFR50.59.Encl Info Covers Period of 981101-9903311999-07-28028 July 1999 Forwards Rept of Changes,Tests & Experiments Performed Per 10CFR50.59 & Revs to USAR Other than Those Resulting from 10CFR50.59.Encl Info Covers Period of 981101-990331 LIC-99-0070, Requests Reinstatement of SRO License Previously Held by K Grant-Leanna (License SOP-43569).Operator Is Current on All requalification-training Topics & Has Completed License Reactivation Program1999-07-28028 July 1999 Requests Reinstatement of SRO License Previously Held by K Grant-Leanna (License SOP-43569).Operator Is Current on All requalification-training Topics & Has Completed License Reactivation Program LIC-99-0071, Informs That Util Expects to Submit Four Licensing Actions in Each of Fys 2000 & 2001,in Response to Administrative Ltr 99-02, Operating Reactor Licensing Action Estimates1999-07-26026 July 1999 Informs That Util Expects to Submit Four Licensing Actions in Each of Fys 2000 & 2001,in Response to Administrative Ltr 99-02, Operating Reactor Licensing Action Estimates LIC-99-0057, Forwards 1999/2000 Statement of Cash Flow from Operations, as Guarantee of Payment of Deferred Premiums for Period of 990630 to 0006301999-07-26026 July 1999 Forwards 1999/2000 Statement of Cash Flow from Operations, as Guarantee of Payment of Deferred Premiums for Period of 990630 to 000630 LIC-99-0069, Forwards non-proprietary & Proprietary Epips,Including FC- Epf Index Page & Page 2 ,rev 0 to FC- EPF-42,EPIP Index (Page 1 of 2) & EPIP-OSC-2, Cover & Pages 19 & 20.Proprietary Encls Withheld1999-07-23023 July 1999 Forwards non-proprietary & Proprietary Epips,Including FC- Epf Index Page & Page 2 ,rev 0 to FC- EPF-42,EPIP Index (Page 1 of 2) & EPIP-OSC-2, Cover & Pages 19 & 20.Proprietary Encls Withheld LIC-99-0066, Forwards Fort Calhoun Performance Indicators Rept for May 19991999-07-0707 July 1999 Forwards Fort Calhoun Performance Indicators Rept for May 1999 LIC-99-0060, Forwards Proprietary & non-proprietary Revs to Fort Calhoun Station Emergency Plan Forms (Epf),Including FC-EPF,FC-EPF-1 & FC-EPF-17.Proprietary Info Withheld1999-07-0101 July 1999 Forwards Proprietary & non-proprietary Revs to Fort Calhoun Station Emergency Plan Forms (Epf),Including FC-EPF,FC-EPF-1 & FC-EPF-17.Proprietary Info Withheld LIC-99-0063, Requests Termination of License Held by MR Anderson (License SOP 43812) for Fort Calhoun Station.Anderson Ended Employment Effective 9906241999-07-0101 July 1999 Requests Termination of License Held by MR Anderson (License SOP 43812) for Fort Calhoun Station.Anderson Ended Employment Effective 990624 LIC-99-0061, Submits Response to GL 98-01, Y2K Readiness of Computer Sys at Nuclear Power Plants. Disclosure Encl1999-06-30030 June 1999 Submits Response to GL 98-01, Y2K Readiness of Computer Sys at Nuclear Power Plants. Disclosure Encl LIC-99-0056, Forwards Rev 2 to EA-FC-90-082, Potential Over- Pressurization of Containment Penetration Piping Following Main Steam Line Break in Containment, to Facilitate Review of Response to GL 96-061999-06-22022 June 1999 Forwards Rev 2 to EA-FC-90-082, Potential Over- Pressurization of Containment Penetration Piping Following Main Steam Line Break in Containment, to Facilitate Review of Response to GL 96-06 LIC-99-0059, Provides Formal Notification to NRC of Plans Re Renewal of Operating License DPR-40 for Unit 1.Util Will Continue to Inform NRC of Decisions Relative to License Renewal in Order to Facilitate NRC Resource Planning1999-06-22022 June 1999 Provides Formal Notification to NRC of Plans Re Renewal of Operating License DPR-40 for Unit 1.Util Will Continue to Inform NRC of Decisions Relative to License Renewal in Order to Facilitate NRC Resource Planning LIC-99-0054, Forwards Manual Containing Description of Fort Calhoun Station 1999 Emergency Preparedness Exercise, to Be Conducted on 9908101999-06-0808 June 1999 Forwards Manual Containing Description of Fort Calhoun Station 1999 Emergency Preparedness Exercise, to Be Conducted on 990810 LIC-99-0052, Forwards Fort Calhoun Station Performance Indicators, for Apr 19991999-06-0202 June 1999 Forwards Fort Calhoun Station Performance Indicators, for Apr 1999 LIC-99-0045, Forwards Application for Amend to License DPR-40,proposing to Relocate pressure-temp Curves,Predicated NDTT Shift Curve & LTOP Limits & Values from FCS TS to OPPD Controlled Document.Rev 3 to TR CE NPSD-683 & Supporting TSs Encl1999-05-26026 May 1999 Forwards Application for Amend to License DPR-40,proposing to Relocate pressure-temp Curves,Predicated NDTT Shift Curve & LTOP Limits & Values from FCS TS to OPPD Controlled Document.Rev 3 to TR CE NPSD-683 & Supporting TSs Encl LIC-99-0046, Forwards Scope & Objectives for Plant 1999 EP Exercise to Be Conducted 990810.Info Provided Ninety Days Prior to Exercise IAW Established Stds.Complete Scenario Package Will Be Submitted to NRC & FEMA Sixty Days Prior to Exercise1999-05-12012 May 1999 Forwards Scope & Objectives for Plant 1999 EP Exercise to Be Conducted 990810.Info Provided Ninety Days Prior to Exercise IAW Established Stds.Complete Scenario Package Will Be Submitted to NRC & FEMA Sixty Days Prior to Exercise LIC-99-0028, Provides NRC with Status of Corrective Actions Re Plant Fire Protection Program,As Result of NRC Insp Rept 50-285/97-06. Mod to MOV Is in Design Phase & Currently Scheduled for Installation During 1999 Refueling Outage1999-04-30030 April 1999 Provides NRC with Status of Corrective Actions Re Plant Fire Protection Program,As Result of NRC Insp Rept 50-285/97-06. Mod to MOV Is in Design Phase & Currently Scheduled for Installation During 1999 Refueling Outage LIC-99-0036, Submits Annual Rept of 1998 Loca/Eccs Models Per 10CFR50.46. Small & Large Break LOCA PCT Values Continue to Remain Less than 10CFR50.46(b)(1) Acceptance Criterion of 2200 F1999-04-28028 April 1999 Submits Annual Rept of 1998 Loca/Eccs Models Per 10CFR50.46. Small & Large Break LOCA PCT Values Continue to Remain Less than 10CFR50.46(b)(1) Acceptance Criterion of 2200 F LIC-99-0043, Forwards Fort Calhoun Performance Indicators Rept for Mar 19991999-04-28028 April 1999 Forwards Fort Calhoun Performance Indicators Rept for Mar 1999 LIC-99-0041, Informs That Util Has Implemented Necessary Actions Associated with Open TACs M92926,M99885,M98619 & M98933 Issues.Items Considered Ready to Close,Subject to Agreement by Nrc/Nrr Project Manager1999-04-27027 April 1999 Informs That Util Has Implemented Necessary Actions Associated with Open TACs M92926,M99885,M98619 & M98933 Issues.Items Considered Ready to Close,Subject to Agreement by Nrc/Nrr Project Manager LIC-99-0037, Responds to NRC 990126 RAI Re GL 97-01, Degradation of CRDM Nozzle & Other Vessel Closure Head Penetrations. Response Confirms with NRC & NEI Recommendations to Utilize Generic Industry Response to Issue1999-04-26026 April 1999 Responds to NRC 990126 RAI Re GL 97-01, Degradation of CRDM Nozzle & Other Vessel Closure Head Penetrations. Response Confirms with NRC & NEI Recommendations to Utilize Generic Industry Response to Issue LIC-99-0039, Forwards Diskette Containing 1998 Annual Rept of Individual Monitoring for Fcs,Per 10CFR20.2206.Diskette Follows File Structure of Reg Guide 8.7,App a1999-04-20020 April 1999 Forwards Diskette Containing 1998 Annual Rept of Individual Monitoring for Fcs,Per 10CFR20.2206.Diskette Follows File Structure of Reg Guide 8.7,App a LIC-99-0038, Forwards 1998 Radiological Environ Operating Rept & Annual Rept for TS Section 5.9.4.A for 980101-981231, for Fcs,Unit 1.Rept Is Presented in Format Outlined in Reg Guide 1.21,rev 1.Results of Quarterly Dose Calculations,Encl1999-04-20020 April 1999 Forwards 1998 Radiological Environ Operating Rept & Annual Rept for TS Section 5.9.4.A for 980101-981231, for Fcs,Unit 1.Rept Is Presented in Format Outlined in Reg Guide 1.21,rev 1.Results of Quarterly Dose Calculations,Encl LIC-99-0033, Forwards Addl Info to Support NRC Review of Response to GL 97-04, Assurance of Sufficient Net Positive Suction Head for ECC & Containment Heat Removal Pumps1999-04-15015 April 1999 Forwards Addl Info to Support NRC Review of Response to GL 97-04, Assurance of Sufficient Net Positive Suction Head for ECC & Containment Heat Removal Pumps LIC-99-0035, Forwards Proprietary Rev 2b to FCS Emergency Plan Form FC-EPF-17 & non-proprietary Revised FC-EPF Forms Index,Rev 5a to FC-EPF-1 & Rev 4 to FC-EPF-15.Proprietary Info Withheld from Public Disclosure1999-04-0808 April 1999 Forwards Proprietary Rev 2b to FCS Emergency Plan Form FC-EPF-17 & non-proprietary Revised FC-EPF Forms Index,Rev 5a to FC-EPF-1 & Rev 4 to FC-EPF-15.Proprietary Info Withheld from Public Disclosure LIC-99-0031, Forwards Application for Amend to License DPR-40,increasing Min Required RCS Flow Rate & Changing SRs for RCS Flow Rate1999-03-31031 March 1999 Forwards Application for Amend to License DPR-40,increasing Min Required RCS Flow Rate & Changing SRs for RCS Flow Rate LIC-99-0032, Forwards Fort Calhoun Station Performance Indicators, for Feb 19991999-03-31031 March 1999 Forwards Fort Calhoun Station Performance Indicators, for Feb 1999 LIC-99-0029, Forwards Response to 990226 RAI for GL 97-05, SG Tube Insp Techniques1999-03-30030 March 1999 Forwards Response to 990226 RAI for GL 97-05, SG Tube Insp Techniques LIC-99-0027, Forwards Rev 16B to FCS Site Security Plan,Rev 2 to FCS Safeguards Contingency Plan & Rev 6 to FCS Training & Qualification Plan.Encls Withheld1999-03-16016 March 1999 Forwards Rev 16B to FCS Site Security Plan,Rev 2 to FCS Safeguards Contingency Plan & Rev 6 to FCS Training & Qualification Plan.Encls Withheld LIC-99-0022, Agrees with NRC Request That Proposed Wording of USAR Section 9.2.5 Included in Be Revised to Indicate That Use of Letdown Sys Following Transient.Revs of Appropriate Pages to ,Encl1999-03-12012 March 1999 Agrees with NRC Request That Proposed Wording of USAR Section 9.2.5 Included in Be Revised to Indicate That Use of Letdown Sys Following Transient.Revs of Appropriate Pages to ,Encl LIC-99-0024, Informs That OPPD Withdraws Applications Submitted by 950626 &1999-03-12012 March 1999 Informs That OPPD Withdraws Applications Submitted by 950626 & LIC-99-0016, Requests Relief from Certain Requirements of Paragraphs IWA- 5242(a) & IWA-5250(a)(2) of ASME Section Xi,For Remainder of Third 10-year Insp Interval on Basis of Attached Proposed Alternatives1999-03-0101 March 1999 Requests Relief from Certain Requirements of Paragraphs IWA- 5242(a) & IWA-5250(a)(2) of ASME Section Xi,For Remainder of Third 10-year Insp Interval on Basis of Attached Proposed Alternatives LIC-99-0023, Forwards FCS Performance Indicators for Jan 19991999-03-0101 March 1999 Forwards FCS Performance Indicators for Jan 1999 LIC-99-0020, Forwards non-proprietary EPIP Index,Page 1 of 2,rev 31 to EPIP-OSC-1, Emergency Classification, FC-EPF Forms Index, Page 1 of 2, Rev 8 to FC-EPF-14 & Rev 15 to RERP-Appendix a, Rerp. Proprietary Version of Rev 15 to RERP, Included1999-02-24024 February 1999 Forwards non-proprietary EPIP Index,Page 1 of 2,rev 31 to EPIP-OSC-1, Emergency Classification, FC-EPF Forms Index, Page 1 of 2, Rev 8 to FC-EPF-14 & Rev 15 to RERP-Appendix a, Rerp. Proprietary Version of Rev 15 to RERP, Included LIC-99-0011, Forwards 1999 Biennial Decommissioning Funding Status Rept for Fort Calhoun Station,Unit 11999-02-0505 February 1999 Forwards 1999 Biennial Decommissioning Funding Status Rept for Fort Calhoun Station,Unit 1 1999-09-08
[Table view] Category:UTILITY TO NRC
MONTHYEARLIC-90-0705, Forwards Suppl to 900906 Application for Amend to License DPR-40,making Administrative Changes to Tech Specs. Justification & NSHC Analysis for Changes Encl1990-09-17017 September 1990 Forwards Suppl to 900906 Application for Amend to License DPR-40,making Administrative Changes to Tech Specs. Justification & NSHC Analysis for Changes Encl LIC-90-0745, Responds to NRC Re Violations Noted in Insp Rept 50-285/90-32.Corrective Actions:Enhancements Made to Facility Mod Procedures & Engineering Instructions1990-09-17017 September 1990 Responds to NRC Re Violations Noted in Insp Rept 50-285/90-32.Corrective Actions:Enhancements Made to Facility Mod Procedures & Engineering Instructions LIC-90-0717, Forwards Operator Licensing Natl Exam Schedule for FY91 Through FY94,per Generic Ltr 90-071990-09-13013 September 1990 Forwards Operator Licensing Natl Exam Schedule for FY91 Through FY94,per Generic Ltr 90-07 LIC-90-0716, Forwards Ref Matl for Preparing Reactor Operator Licensing Exams Scheduled for 901113.W/o Encls1990-09-13013 September 1990 Forwards Ref Matl for Preparing Reactor Operator Licensing Exams Scheduled for 901113.W/o Encls LIC-90-0740, Forwards Rev 0 to EA-FC-90-062, Diesel Generator Upper Temp Operating Limits,Engineering Analysis. Both Generators Operable & Will Perform Safety Function Consistent W/ Specified Ambient Air Temp Limits1990-09-12012 September 1990 Forwards Rev 0 to EA-FC-90-062, Diesel Generator Upper Temp Operating Limits,Engineering Analysis. Both Generators Operable & Will Perform Safety Function Consistent W/ Specified Ambient Air Temp Limits LIC-90-0741, Submits Plan for Replacement of Remaining Two Control Element Assemblies Which Contain All B4C Pellets1990-09-0707 September 1990 Submits Plan for Replacement of Remaining Two Control Element Assemblies Which Contain All B4C Pellets LIC-90-0440, Forwards Application for Amend to License DPR-40,revising Tech Specs to Make Administrative Changes1990-09-0606 September 1990 Forwards Application for Amend to License DPR-40,revising Tech Specs to Make Administrative Changes LIC-90-0667, Responds to NRC Re Violations Noted in Insp Rept 50-285/90-30 Re Inadequate post-maint Testing Instructions. Corrective Actions:Maint Work Order Written & Performed to Tighten Actuator Diaphragm Bolts on 9005291990-09-0404 September 1990 Responds to NRC Re Violations Noted in Insp Rept 50-285/90-30 Re Inadequate post-maint Testing Instructions. Corrective Actions:Maint Work Order Written & Performed to Tighten Actuator Diaphragm Bolts on 900529 LIC-90-0712, Forwards fitness-for-duty Program Performance Data for Period of Jan-June 19901990-08-31031 August 1990 Forwards fitness-for-duty Program Performance Data for Period of Jan-June 1990 LIC-90-0683, Forwards Responses to Recommendations in SALP Rept 50-285/90-24.Util Currently Developing Corporate Level Procedure to Provide Guidance on Operability Determinations1990-08-27027 August 1990 Forwards Responses to Recommendations in SALP Rept 50-285/90-24.Util Currently Developing Corporate Level Procedure to Provide Guidance on Operability Determinations LIC-90-0627, Responds to Generic Ltr 89-19 Re USI A-47 on Safety Implications of Control Sys in Lwrs.Util Reconsidered Original Commitment Noted in & Does Not Plan to Implement Automatic Steam Generator Overfill Protection1990-08-22022 August 1990 Responds to Generic Ltr 89-19 Re USI A-47 on Safety Implications of Control Sys in Lwrs.Util Reconsidered Original Commitment Noted in & Does Not Plan to Implement Automatic Steam Generator Overfill Protection LIC-90-0670, Forwards Fort Calhoun Station Performance Indicators for Jul 19901990-08-22022 August 1990 Forwards Fort Calhoun Station Performance Indicators for Jul 1990 LIC-90-0662, Forwards Rev 1 to Monthly Operating Rept for June 1990 for Fort Calhoun Station Unit 1,for Proper Distribution1990-08-22022 August 1990 Forwards Rev 1 to Monthly Operating Rept for June 1990 for Fort Calhoun Station Unit 1,for Proper Distribution LIC-90-0673, Retransmits Original Response of Util Responding to Violations Noted in Insp Rept 50-285/90-25.W/o Encl1990-08-22022 August 1990 Retransmits Original Response of Util Responding to Violations Noted in Insp Rept 50-285/90-25.W/o Encl LIC-90-0636, Forwards Results of 1990 Refueling Outage Inservice Insp & Rept for Repairs or Replacement1990-08-13013 August 1990 Forwards Results of 1990 Refueling Outage Inservice Insp & Rept for Repairs or Replacement LIC-90-0591, Provides Info Re RCS Leak Detection Sys to Detect Leaks from Primary Piping Sys to Containment,Per Generic Ltr 84-04 & USI A-21990-08-13013 August 1990 Provides Info Re RCS Leak Detection Sys to Detect Leaks from Primary Piping Sys to Containment,Per Generic Ltr 84-04 & USI A-2 LIC-90-0631, Responds to Generic Ltr 89-15 Re NRC Solicitation of Utils to Voluntarily Participate Emergency Response Data Sys Program.Util Prepared to Work W/Nrc to Investigate Actions Necessary to Implement Program at Plant1990-08-0808 August 1990 Responds to Generic Ltr 89-15 Re NRC Solicitation of Utils to Voluntarily Participate Emergency Response Data Sys Program.Util Prepared to Work W/Nrc to Investigate Actions Necessary to Implement Program at Plant LIC-90-0485, Confirms Interim Resolution of Identified Problem Associated W/Use of Input Variable for PORV Opening Time in Calculation of Low Temp Overpressure Protection Sys Setpoints1990-08-0707 August 1990 Confirms Interim Resolution of Identified Problem Associated W/Use of Input Variable for PORV Opening Time in Calculation of Low Temp Overpressure Protection Sys Setpoints LIC-90-0645, Forwards Application for Amend to License DPR-40,making Typo & Administrative Corrections to Tech Specs1990-08-0202 August 1990 Forwards Application for Amend to License DPR-40,making Typo & Administrative Corrections to Tech Specs LIC-90-0647, Informs That Tl Patterson Assumed Position of Plant Manager, Effective 9008011990-08-0101 August 1990 Informs That Tl Patterson Assumed Position of Plant Manager, Effective 900801 LIC-90-0659, Advises of Plans to Achieve Operability of Third Auxiliary Feedwater Pump by 9008101990-07-31031 July 1990 Advises of Plans to Achieve Operability of Third Auxiliary Feedwater Pump by 900810 LIC-90-0449, Forwards Rev 1 to EA-FC-90-037, Control Room Habitability Evaluation for NUREG-0737,Item III.D.3.41990-07-20020 July 1990 Forwards Rev 1 to EA-FC-90-037, Control Room Habitability Evaluation for NUREG-0737,Item III.D.3.4 LIC-90-0588, Provides Notification of SPDS Implementation at Plant,Per1990-07-19019 July 1990 Provides Notification of SPDS Implementation at Plant,Per LIC-90-0585, Forwards Simulator Malfunction Cause & Effects1990-07-18018 July 1990 Forwards Simulator Malfunction Cause & Effects LIC-90-0581, Informs That Requirements of NRC Bulletin 90-001, Loss of Fill Oil in Transmitters Mfg by Rosemount Satisfied.None of 48 Transmitters in Use at Plant Exhibited Symptoms Indicative of Fill Oil Problems Since Installation in 19871990-07-18018 July 1990 Informs That Requirements of NRC Bulletin 90-001, Loss of Fill Oil in Transmitters Mfg by Rosemount Satisfied.None of 48 Transmitters in Use at Plant Exhibited Symptoms Indicative of Fill Oil Problems Since Installation in 1987 ML20055D9351990-07-0202 July 1990 Forwards Fort Calhoun Station Performance Indicators,May 1990 LIC-90-0564, Forwards Updated, Position Paper Re Seismic Capability of Welded Steel Piping. Documentation Demonstrates No Generic Thermal or Seismic Safety Issue Exists for Welded Steel Small Diameter Piping at Facility1990-06-29029 June 1990 Forwards Updated, Position Paper Re Seismic Capability of Welded Steel Piping. Documentation Demonstrates No Generic Thermal or Seismic Safety Issue Exists for Welded Steel Small Diameter Piping at Facility LIC-90-0522, Forwards Revised Response to Notice of Deviation from Insp Rept 50-285/90-02.Corrective Actions:Cable Trays 5-4A & 5-4B Reworked to Neatly Tie Down Cables & Remove Crossovers & Engineering Instruction GEI-9 on Electrical Sys Updated1990-06-29029 June 1990 Forwards Revised Response to Notice of Deviation from Insp Rept 50-285/90-02.Corrective Actions:Cable Trays 5-4A & 5-4B Reworked to Neatly Tie Down Cables & Remove Crossovers & Engineering Instruction GEI-9 on Electrical Sys Updated LIC-90-0566, Forwards 1990/1991 Statement of Cash Flow from Operations. Cash Flow Statement Deviates from Reg Guide 9.4 Due to Util Being Political Subdivision of State of Ne1990-06-29029 June 1990 Forwards 1990/1991 Statement of Cash Flow from Operations. Cash Flow Statement Deviates from Reg Guide 9.4 Due to Util Being Political Subdivision of State of Ne LIC-90-0488, Responds to Request for Info Re Status of Implementation of Generic Safety Issue Requirements1990-06-29029 June 1990 Responds to Request for Info Re Status of Implementation of Generic Safety Issue Requirements LIC-90-0446, Forwards Application for Amend to License DPR-40,to Restrict Containment Spray Use as Backup for Shutdown Cooling in Tech Specs1990-06-28028 June 1990 Forwards Application for Amend to License DPR-40,to Restrict Containment Spray Use as Backup for Shutdown Cooling in Tech Specs LIC-90-0429, Forwards Application to Amend License DPR-40,adding Hydrogen Purge Sys to Tech Spec.Discussion,Justification & NSHC Analysis for Amend,Provided1990-06-28028 June 1990 Forwards Application to Amend License DPR-40,adding Hydrogen Purge Sys to Tech Spec.Discussion,Justification & NSHC Analysis for Amend,Provided ML20044A1631990-06-22022 June 1990 Requests That NRC Continue Processing Exemption Request for Configuration of wide-range Nuclear Instrumentation Cables in Fire Area 34B (Upper Electrical Penetration Room). Emergency Boration Added to Achieve Safe Shutdown ML20043J0611990-06-22022 June 1990 Responds to NRC 900523 Ltr Re Violations Noted in Insp Rept 50-285/90-29.Corrective Actions:Five Chemistry Technicians Provided Refresher Training on 900427 on Existing EPIP-EOF-6 ML20044A4961990-06-18018 June 1990 Forwards Supplemental Application for Amend to License DPR-40,making Administrative Corrections to Tech Specs. Procedure SO-G-70, Chemical Control Also Encl ML20043G2981990-06-14014 June 1990 Provides Followup to Special Rept on Inoperable Fire Barriers.Eight Inoperable Dampers Replaced Under Mod MR-FC-87-036, Fire Damper Replacement. Remaining 38 Dampers Found to Be Acceptable After Damper Design Review ML20043E6451990-06-0808 June 1990 Provides Supplemental Response to Generic Ltr 88-17 & NRC Bulletin 80-12.Plant Pumps & Suction Header Piping Not Originally Constructed for Use as Backup to LPSI Sys for Shutdown Cooling ML20043G3281990-06-0101 June 1990 Advises That Personnel at Util Reviewed Reactor Operator Licensing Exam Administered on 900529.Comments on Exam Encl ML20043E0071990-06-0101 June 1990 Discusses Rev to Previous Commitments Made in Response to Requirements of 10CFR50,App R,Section Iii.G Re post-fire Repairs to Equipment Required for Cold Shutdown Following Fire in Fire Area 6 ML20043C1811990-05-29029 May 1990 Advises That Util Has Cleaned RW HXs AC-1A & AC-1D & Will Clean AC-1C by 900615 ML20043B4981990-05-24024 May 1990 Updates Schedule for Submitting Results of PORV Block Valve Prototype Testing.Establishment of Test Parameters & Development of Test Procedures Tentatively Scheduled for Submittal in Nov 1990.Final Rept Expected by 910630 ML20043B5061990-05-23023 May 1990 Advises That Testing to Verify Operability of Hydrogen Purge Sys Successfully Completed During 1990 Refueling Outage.Proposed Tech Spec Rev Will Be Submitted by 900701 ML20043B4731990-05-23023 May 1990 Forwards Fort Calhoun Station Performance Indicators, Monthly Rept for Apr 1990 ML20043A8021990-05-18018 May 1990 Advises That Walkdown of safety-related Portions of Plant to Verify Accuracy of Fire Barrier Penetration Drawings & Surveillance Tests Will Be Completed by 900831 ML20043A7821990-05-18018 May 1990 Advises That Licensee Plans to Replace Valves HCV-247 & HCV-2988 During 1991 Refueling Outage Pending Successful Redesign & Retesting of New Valves by Valcor ML20043B0391990-05-16016 May 1990 Informs of Current Status of Post Accident Sampling Sys. Program Meets Min Requirements & Fulfills Conditions of Tech Spec 5.15 ML20042G9861990-05-11011 May 1990 Forwards Rev 0 to Interim Operability Criteria (Ioc) Criteria for Performing Safety Analysis for Interim Operability of Piping, Resulting from Discussion at 900306 & 0418 Meetings ML20042G9571990-05-10010 May 1990 Forwards Suppl to Application for Amend to License DPR-40, Making Administrative Clarification to Chloride Sampling Requirements.Standing Order Procedure S.O.-M-10, Tool Accountability Also Encl ML20042H0021990-05-10010 May 1990 Fowards Fort Calhoun Station Performance Indicators,Mar 1990, Monthly Rept ML20042G9981990-05-10010 May 1990 Forwards Proprietary & Nonproprietary Rev 13 to EPIP-EOF-18, Offsite Radiological Surveys. 1990-09-07
[Table view] |
Text
~
y l l
, .. t l 1..
L;
- June 29, 1990 Omaha Public Power District LIC-90-0564 1623 Harney Omaha, Nebraska 68102 2247 402/536 4000 U. S. Nuclear Regulatory Commission Attnr Document Control Desk Mail Station P1-137 Washington, DC 20555 l
REFERENCES:
- 1. Docket 50-285
- 2. Letter from OPPD (K. J. Morris) to NRC (Document Control ,
Desk) dated December 2, 1988 (LIC-88 0506) l
SUBJECT:
Update of Plans Regarding Small Bore Pipe Support Spacing Reference 2 provided a description of Omaha Public Power Districts (OPPD)'
actions planned with respect to safety-related small bore piping. _These actions included 1) documenting as-built small-bore pipe support locations, and
- 2) review of as-built pipe support locations against the new nomograph / Alternate Seismic Criteria. OPPD is extending the completion date of these two items to December 31, 1994 and December 31, 1995, respectively.
OPPD's current position on piping and restraint qualification issues related to small diameter piping is presented in the attached documentation. This documentation demonstrates that no generic thermal or seismic safety issue ,
exists for welded steel small diameter piping at FCS, OPPD is developing.a generic program for resolving outstanding piping issues to present to the NRC.
This program will identify priorities, schedules and resources based on the ,
relative safety significance and benefit of resolving various issues. l 1
These new commitment dates are consistent witn the emerging generic piping program schedules and will allow the interim development and approval of criteria and procedures which would be appropriate for performing qualification reviews, if warranted, of small diameter piping systems.
If you should have any questions, please contact me.
Sincerely, l l
N. ..
L W. G. Gates Division Manager Nuclear Operations WGG/sel Ok kObh $bOhib$sr_;
P PDC c: LeBoeuf, Lamb, Leiby & MacRae A. Bournia, NRC Project Manager R. D. Martin, NRC Regional Administrator, Region IV P. H. Harrell, NRC Senior Resident Inspector 0[
10 1
- b h!b$ ^4* M r.(Py l ( { a%()(jf))p ( ) (j gy(g l
4 ,
OPPD POSITION PAPER REGARDING THE SEISMIC CAPABILITY OF WELDED STEEL PIPING R.E. Lewis, P.E.
May 3, 1990 I. PURPOSE <
To document the following:
i
- 1) That existing seismic design features (of CQE piping at Ft.
Calhoun) and data obtained from various walkdowns, provide a high level of confidence that the piping will perform adequately for-the design basis earthquake events.
- 2) That a significant level of conservatism exists in the design basis seismic qualification process for Ft. Calhoun.
- 3) That welded steel piping systems are inherently rugged seismically.
- 4) That various technical and documentation deficiencies, which have been identified in our piping seismic analyses over the '
years, are insignificant in comparison to the overall seismic capacity of the systems.
- 5) That no significant seismic safety concern exists, for welded steel piping systems, at Ft. Calhoun. ;
II. EXISTING' CONDITIONS The CQE piping at Ft. Calhoun was originally designed for seismic '
-loads, using methods less rigorous than current practice but which were deemed appropriate at the-time. Since then, "as-built" walkdowns, complete reanalysis and substantial modifications were p(using updated erformed to methods) "as-built reconcile and design discrepancies" found during resolution of NRC IEB 79-02 &
79-14. In addition, we have performed verification walkdowns for the District's Design Basis Reconstitution program, and continued'to evaluate.and resolve various seismic issues in combination with other work requiring reanalysis of piping. Therefore a significant margin of seismic capacity has been incorporated into the CQE piping systems as they exist today.-
However, miscellaneous documentation and technical' issues, with regard to demonstrating the seismic qualification of CQE piping at Ft.'Calhoun, have surfaced over the years. Some of the past piping design inputs, assumptions and modeling practices are undocumented and/or inconsistently applied. The basis for many of the " apparent assumptions" are unknown and not supported by historical industry practice.
by current The associated standards calculations and practices. and documentation Calculations are deficient which reconcile these-deficiencies, often indicate that various piping and/or -
restraint limits.
components are outside the Seismic class I design basis
g 9 g I
Calculations and criteria, prepared for.the District's Alternate Appendix F Criteria documents (Ref. 9 & 10), demonstrate that significant conservatisms exist in the Design Basis seismic inputs when compared to those derived with current practice methods and
. criteria. Many of the technical deficiencies noted above, are insignificant in comperison to these excess conservatisms.
e III. EXPECTED PERFORMANCE UITH EXISTING CONDITTONS >
The current and past seismic analysis practices, as they apply to nuclear piping design and qualification, are now known to significantly overpredict seismic failures (Ref. 7: p.136, p.158, p.164; Ref. 8: p.67, p.217, p.220, p.233). The over-conservatisms for piping seismic anslysis are three fold: 1) analysis methods 2) seismic input data and 3) code acceptance criteria.
Analysis methods have been refined over the years, but still '
typically calculate seismic responses based on the assumption of-linear elastic behaviour, use of response spectra methods, conservative Regulatory Guide 1.92 modal combinations (Ref. 7: p.158, p.167) and Regulatory Guide 1.61 damping values or lower in lieu of higher empirical values. pipe stresses calculated by the response spectra method can be 2 to 8 times that resulting from a more exact time history method (Ref. 15, p.6). Actual behaviour of seismically excited piping systems displays significant energy dissipation and is non-linear in nature Measured responses are(Ref. 7: p.134; Ref. 8: p.205, p.229, p.233).
usually much lower than calculated (Ref. 7:
p.168; Ref. 8: p.67, p.220, p.229).
In addition, the seismic input Floor Response Spectra (FRS) contain artificial conservatisms in the form of Regulatory Guide 1.122 peak broadening, smoothing and enveloping (Ref. 7: p.134, p.158). The seismic structural analysis process, which is used to derive the piping FRS, contains similar conservatisms to the piping analysis process and therefore compounds the conservatisms. Calculations, performed for the District's Alternate Appendix F Criteria (Ref. 10),
demonstrate that significant conservatisms exist in the Design Basis seismic inputs when methods and criteria. compared to those derived with current practice The piping code criteria, against which calculated seismic inertia stresses are compared, is known to be unrealistic and overly conservative (Ref. 7: p.164, p.168; Ref. 8: p.67, p.229, p.233).
Failures modes due to seismic loading have been shown, throuch testing and industry research programs (Ref. 13 & 14), to be caused ~
by fatigue and ratcheting instead of plastic collapse which is the basis for the piping code criteria. Numerous stress reversal cycles (f ar more than would result from actual earthquakes) are needed to induce failure. The codes, however, treat inertia as a primary stress and limit the stress amplitudes without regard to the limited number of cycles involved.
Therefore the cumulative conservatisms inherent in the seismic qualification process are significant and lead to over-prediction of seismic failures. However, relaxation of these excess conservatisms is not currently permited in our licensing basis.
The actual earthquake experiences of others, have proven tian and again that typical power piping systems are inherently rugged seismically. A significant amount of piping performance experience data has been collected from surveys of at least 29 different >
earthquakes around the world and from testing recently performed for/by recognized- industry organizations. This data demonstrates that the rare instances of seismically induced piping failures can be attributed to a limited number of root causes as follows (Ref. 1&
2):
Seismic Anchor Movement (SAM)- insufficient flexibility in piping restrained by_different structures or equipment that move rela-tive to each other, can result in breach of pressure boundary and/or restricted flow.
Spatial Interaction (SPI)- inadequate clearance between vulnerable components, like control valves, and other structures or equipment can cause loss of function and/or restricted flow.
Corrosion - excessive thining of the pipe wall, due to corrosion, can result in breach of pressure boundary and/or structural-fail-ures.
Non-Welded Joints - screwed fittings are vulnerable to breach of pressure boundary failure due to the stress concentrations and reduced cross section present at the thread roots and bolted flange joints might develope leaks.
s Welded steel piping systems, designed to standard industry piping codes (even when not designed seismically), exhibit adequate perfor--
mance in earthquakes (with recorded peak ground accelerations as high as 0.99) with few exceptions (Ref. 1). Piping restraint failures, on these same lines, are not uncommon and provide pressure boundary protection by acting as mechanical fuses to provide additional flexi-bility where needed to accomodate SAM movements (Ref. 2). It can be concluded from the above that good seismic design results from provid-ig the necessary flexibility to accomodate SAM, providing sufficient clearances to prevent Spl, providing allowance for errosion/ corrosion and avoiding the use of non-welded joints. performing rigorous dynam-ic analysis (which is known to significantly over predict the seismic behavior of piping) and applying arbitrary code stress limits (which are known to be unrealistic and over conservative for seismic loads; Ref. 3,
- p. 2-17) are not required to achieve adequate margin against l aeismic induced piping failures and may in fact result in designs which are less reliable than those for which no seismic design is employed (Ref. 2: R. Cloud, p. 81 & Sect. 5.1.3, p. 84).
l' l
1
.Recent testing through programs such as the "EPRI/NRC Piping and Fitting Dynamic Reliability. Program" (Ref. 13) have provided-the industry with considerable insight into the credible failure mechanisms relative to seismically' induced response. This data shows that (Ref. 1) :
" Sound and uncracked piping is " Fail-Proof" to any conceivable seismic inertia loads in LWR-type plants (more than 10 times current ASME SSE-allowable load levels are required to induce pipe failuro)."
"There is a natural mechanism to relieve high seismic elastic calculated pipe stresses, and the mechanism is plastic energy dissipation which behaves like increased damping."
"The piping failure mode under super seismic type loading is fatigue and ratcheting, and not static collapse as assumed by the current ASME Code rules." ;
"The ratchet / fatigue failuro condition has no sharply defined stress level at which pipe functionality is lost as in the case of a static collapse mode."
" Current ASME Code Allowable Stress Criteria with linear dynamic analysis is a very conservative and unrealistic measure of pipe failure caused by excessive seismic type loads. (The fatigue i criteria of the Code is OK) ." ;
"The research explains why it is not necessary to provide horizon- i tal support to piping subjected to seismic loading to protect the pipe from stress collapse. The main benefit from horizontal sup-port is to prevent excessive pipe displacement."
" Fatigue and ratcheting damage due to one or two large earth-quakes will generally cause insignificant damage to=any reason-ably designed piping system (with or without nuclear standards)."
In summary, seismic induced stresses in velded steel piping systems is not a credible safety concern provided that no SAM, SPI, errosion/
corrosion or non-welded j oint issues exist. In addition, it has been-recommended that explicit earthquake design requirements be eliminated, for piping subjected to a SSE-ZPGA.less than 0.2g, since no such observed piping (Ref.
low magnitude system failures have been noted for earthquakes of 2, Sect. 5.2.2, p.
85).
-e e 1
With respect to the Fort Calhoun CQE piping systems, the following is
-known:
1)~The equipment to which CQE piping is attached and the piping i itself, was designed to be seismically rigid, and eas anchored to i resist seismic loads. Therefore, relative movement between l equipment and piping located in the same building structures, at the same elevation, will be insignificant with respect to inducing SAM loads on piping. Furthermore, the Containment and Auxiliary building structures are founded on a common mat and designed to resist seismic loads. Relative SAM movements between and within these structures is known to be insignificant. Seismic movements between the Auxiliary and Turbine building structures is significant. The CQE Main Steam and Feedwater piping routed between these structures has been evaluated for the resultant SAM loads. No other'CQE piping is presently routed between these two-structures. Therefore, no generic SAM concerns exist for CQE piping at Ft. Calhoun.
- 2) The most vulnerable piping components, from the standpoint of SPI concerns, are valve actuators. The seismic design of CQE piping systems, at Ft. Calhoun, typically provided three way seismic restraints on the piping at the location of control 1 valves. In addition, out-of-plane restraints were provided for eccentric valve operator masses. Seismic displacement of the valves into other structures or equipment, is thereby prevented.
In general, the original seismic design of CQE piping provided sufficient restraint to acheive rigid- response with respect to.
the building structures. In addition, modifications were made for ;
IEB 79-02 & 79-14'which.provided additional restraints to limit
. pipe stresses and support loads to within. acceptable limits.
Therefore, interaction with other piping components and adjacent valves is unlikely. In addition, we have observed that other structures and/or equipment located near CQE equipment were designed and constructed to prevent SPI. Field inspections of CQE piping, perf ormed for the District 's IEB 79-14 program, evaluated clearances between piping components and surrounding structures-and equipment to_ ensure'that thermal expansion would not be j inhibited. Clearances were also observed'during walkdowns performed for the Design Basis Reconstitution project. Clearances '
were-found to be adequate. Further review of SPI, with respect to control valves, will be performed for resolution of NRC USI A-46.
For the CQE Main Steam and Feedwater piping, one instance of-
, potential SPI was noted between a MS Isolation Valve and an L adjacent FW seismic restraint structure. The potential SPI results from the significant displacements of the MS line l predicted to occur in the event that all lateral seismic L restraints would fail (this has been conservatively assumed for l l purposes of demonstrating operability under worst case l conditions). A modification was performed to eliminate that SPI L concern (Ref. 11 & 12). In general, no generic spi concerns exist l for CQE piping systems at Ft. Calhoun. A program is to be I
' implemented in the near future for USI A-46 which will provide additional documentation or corrective actions to support this conclusion.
l l
1 i
l
- 3) The use of corrosion resistant materials, chemical treatment and current monitoring and replacement programs for controling errosion/ corrosion are judged to eliminate these effects from being a concern with respect to seismic induced failures.
- 4) All known joints in CQE piping (excluding instrumentation lines) at Ft. Calhoun are either welded or flanged. The flanged joints were specified to use high strength bolts so that complete failure due to seismic loads is unlikely although some leakage may result. The welded joints recieved inspections as required by the appropriate codes to ensure quality and critical welds are periodically re-inspected thru the District's ongoing ISI program..Therefore, no generic concern with regard to non-welded or poorly welded joints exists at Ft. Calhoun.
- 5) The Fort Calhoun site SSE-ZPGA was determined to be 0.12g, from seismological studies, and conservatively established as 0.17g for design basis. Since these values are less than 0.2g, explicit design requirements for seismic loads would seem unwarranted.
IV. CONCLUSION We conclude that: 1) a significant margin of seismic capacity exists in "as-built" design features of CQE piping at Ft. Calhoun the design basis seismic qualification process significantly 2) that over-predicts seismic responses 3) that welded steel piping is inherently rugged seismically 4) that outstanding technical and documentation deficiencies, regarding the seismic qualification of CQE piping at Ft. Calhoun, are insignificant in comparison to the demonstrated superior seismic performance of welded steel piping in actual earthquakes 5) and that no generic seismic safety concern exists with regard to CQE piping at Ft. Calhoun.
1 l
. . ,4 REFERENCE LIST
- 1) Procedure for Seismic Evaluation and Design of Small Bore Piping (NCIG-14), Sept. 29, 1989, EPRI NP-6628, Project Q101-16,17
- 2) Report of the U.S. Nuclear Regulatory Commission Piping Review Committee, USNRC, NUREG-1061, Vol. 2 ADDENDUM
- 3) Report of the U.S. Nuclear Regulatory Commission Piping Review Committee, USNRC, NUREG-1061, Vol. 2
- 4) Regulatory Analysis for Resolution of Unresolved Safety Issue A-46, Seismic Qualification of Equipment in operating Plants, USNRC, NUREG-1211
- 5) Task Actions Plans for Unresolved Safety Issues Related to Nuclear Power Plants, USNRC, NUREG-0649, Rev. 1
- 6) Generic Implementation Procedure (GIP) for Seismic Verification of Nuclear Plant Equipment, SQUG, Dec. 1988, Rev. 1
- 7) "Recent Advances in Seismic Design of Piping and Components",
Proceedings of the 1985 Pressure Vessels and Piping Conference, PVP-Vol. 98-3
- 8) " Seismic Engineering- Recent Advances in Design, Analysis, Testing and Qualification Methods", The 1987 Pressure Vessels-and Piping Conference, PVP-Vol. 127
- 9) " Alternate Seismic Criteria & Methodologies for Fort Calhoun Station", Volumes I & II, July 1988.
' 10) " Generation of In-Structure Response Spectra for Fort Calhoun Unit-1", Vol. I, II & III, Jan. 1989 t
l
- 11) MR-FC-89-45, "Feedwater Supports in Room 81 & Turbine Building"
- 12) MR-FC-90-19, " Main Steam Supports in Room 81 & Turbine Building" L 13) EPRI Report No. RP1543-15, " Piping and Fitting Dynamic l
Reliability Program", Dec. 1989
- 14) EPRI Report No. NP-3746, " Dynamic Response of Pressurized Z-Bend u Piping Systems Tested Beyond Elastic Limits and with Support Failures", Dec. 1984
- 15) NUREG/CR-3718, UCID-19722, " Reliability Analysis of Stiff Versus Flexible Piping - Status Report", April 1984 l
-a-