ML20034E306

From kanterella
Jump to navigation Jump to search
Ref Sec 2 - Health Physics Sample Records
ML20034E306
Person / Time
Site: San Onofre  
Issue date: 04/16/2016
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034E306 (10)


Text

Health Physics Sample Records Sample ID:

142516 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140523BD02 BACKGROUND SECURITY# 2 lcommon1 Resp Org: P4000 - PROJECT MANAGEMEt

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments: COUNT TO MDA Origin I Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Date: 06/10/1413:15 Unknown Mat:

NO Mat. SizeNolume:

1764 GRAMS Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00

==

Description:==

BACKGROUND SECURITY# 2 Collection Sample Tech:

DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA I RLSSS I Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes I Location Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Other: COUNT TO MDA Material Loe:

06/19/201411:51 Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

!li" Elev: 100 Room:

Date: 00/00/00 00:00 Sample Date: 05/23/1411 :20 Sample SizeNolume: 1764 GRAMS Depth: 3" (in.)

Equip ID:

Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Sample ID:

142516 Type: RLSSS Type Detail: SAND

==

Description:==

140523BD02 BACKGROUNq SECURITY# 2 Analysis Geometry A_ 1 L_marinelli_sand_

MCA ID Quant.

Units Method 1011 1764GR lsoto~ Mod~ Activitl._

Activity Uncert.

LLD/MDA 0

K-40 NT 0

TL-208 NT 0

PB-212 NT 0

Bl-214 NT 0

PB-214 NT 0

RA-226 NT 0

AC-228 NT 0

U-235 NT 0

BE-7 AP 0

MN-54 AP 0

MN-56 AP 0

C0-57 AP 0

C0-58 AP 0

C0-60 AP 0

SB-124 AP 0

SB-125 FP 0

CS-134 FP 0

CS-137 FP I Analysis Review I 0.000014311.69E-6 3.184E-7 1.245E-7 6.544E-7 1.171E-7 3.869E-7 1.238E-7 5.384E-7 2.302E-7 2.717E-6 1.142E-6 5.727E-7 1.808E-7 1.682E-7 7.4E-8 1.0196E-6 1.3763E-7 1.5907E-7 1.0102E-7 1.2632E-7 4.8612E-8 8.3534E-8 2.963E-7 8.3958E-8 1.0464E-7 r

r r r Iv Iv Iv Iv Iv Iv iv*

Iv Iv Iv Health Physics Sample Records Status: APPROVED FP/AP Lab Analysis By

.000 DYNES, WILLIAM J

%Abund.

Atom. No.

Comments 72.765%

40 1.619%

208 3.328%

212 1.967%

214 2.738%

214 13.816%

226 2.912%

228 0.855%

235 0.000%

7 0.000%

54 0.000%

56 0.000%

57 0.000%

58 0.000%

60 0.000%

124 0.000%

125 0.000%

134 0.000%

137 Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L HP Notified Name:

Hp Eng Rvw Reqd:

Yes Rad Mat Present:

Yes Comments: COUNT TO MDA 06/19/201411:51 Rasterized: r Date Mod ID Mod Date 06/10/14 13:43 Mod Id Mod Date Date: 06/11/14 08:17 Page 2 of 3

Health Physics Sample Records Sample ID:

142516 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140523BD02 BACKGROUND SECURITY#2 I Review/A.pprovel HP Review Reviewed: COOPER, TERRY L Date: 06/11/14 08:18 Comments: U-235 is likely a mis-ID off the Ra-226 energy peak Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/19/201411:51 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/11/14 08:18 Rasterized: r Page 3 of 3

SONGS HEALTH PHYSICS REPORT 10-JUN-2014 13:31

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140523BD02 BACKGROUND SECURITY# 2

  • ID
  • Start Time:
  • Stop Time:
  • Quantity 1011 10-JUN-2014 13:28:00 10-JUN-2014 13:28:00
1. 76400E+03 GR Acquisition date: 10-JUN-2014 13:28:47 *
  • Geometry A 11 marinelli sand 1 Operator: BILL Counting System IHPS Sample Number:

Analysis Library DYNES UlGSP 142516 HP NATURAL

>>>>> A -1922924

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.26 0 00:03:00.33 0.0%

l.OOOOOE+OO 8.00000 PARAMETERS<<<<<

Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 10-JUN-2014 00:04

-l.04456E-01 4.99840E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1

186.08 23 21

1. 48 372.47 367 9 41. 9 1. 80E+OO U-235 RA-226 1

238.63 65 17

1. 33 477.61 472 10 17.4 3.95E-01 PB-212 1

295.17 20 14

1. 89 590.70 586 11 42.6 4.97E-01 PB-214 1

352.25 41 9

1. 66 704.90 700 9 20.1 l.46E+OO PB-214 1

583.04 19 7

0.79 1166.54 1158 14 38.7 7.88E+OO TL-208 1

609.30 19 5

1. 73 1219.07 1214 10 31. 7 3.77E-01 BI-214 1

911. 45 13 0

1. 26 1823.40 1817 10 29.6 6.16E-Ol AC-228 1

1460.84 81 0

2.18 2922.05 2916 12 11. 2 5.08E-01 K-40

Unidentified Energy Lines Sample ID : 1011 None Flags: "T" Tentatively associated Acquisition date Page :

3 10-JUN-2014 13:28:47

Interference Report Sample ID : 1011 No interference correction performed Acquisition date Page :

4 10-JUN-2014 13:28:47

Nuclide Line Activity Report Page :

5 Sample ID : 1011 Acquisition date 10-JUN-2014 13:28:47 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 81 10.67*

4.482E-01

1. 431E-05
1. 431E-05
11. 80 TL-208
72. 80 2.14 l.155E+OO Line Not Found ------

74.97 3.60 1.239E+OO ------

Line Not Found ------

84.79 ------

1. 27
1. 578E+OO ------

Line Not Found ------

252.45 ------

0.80

1. 887E+OO Line Not Found ------

277.28 6.80

1. 783E+OO Line Not Found ------

510.61 ------

21. 60 1.121E+OO Line Not Found ------

583.02 19 86.00*

9.954E-01

1. 929E-07 3.184E-07 39.12 763.06 ------
1. 64 7.714E-01 ------

Line Not Found ------

860.30 ------

12.00 6.870E-01 ------

Line Not Found ------

PB-212 74.81 ------

10.50 1.233E+OO Line Not Found ------

77.11 ------

17.70 1.319E+OO Line Not Found ------

87.19 ------

6.27 l.650E+OO Line Not Found ------

90.13

1. 86
1. 730E+OO Line Not Found ------

115.12 ------

0.59 2.162E+OO Line Not Found ------

238.58 65 43.60*

1. 948E+OO 6.527E-07 6.544E-07 17.90 300.03 ------

3.34 l.694E+OO Line Not Found ------

BI-214 76.86 ------

0.58 l.310E+OO Line Not Found ------

79.29 ------

0.97 1.397E+OO Line Not Found ------

609.31 19 46.10*

9.557E-Ol 3.574E-07 3.869E-07

31. 99 665.44
1. 56 8.797E-01 ------

Line Not Found ------

768.35 ------

4.88 7.663E-01 ------

Line Not Found ------

806.16 ------

1. 23 7.315E-01 ------

Line Not Found ------

934.04 ------

3.16 6.352E-Ol ------

Line Not Found ------

1120. 27 15.00 5.391E-01 ------

Line Not Found ------

1155.18 ------

1. 69 5.255E-01 ------

Line Not Found ------

1238.11 ------

5.92 4.976E-01 Line Not Found ------

1280.95 ------

1. 47 4.855E-01 ------

Line Not Found ------

1377. 66 4.02 4.629E-01 ------

Line Not Found ------

1385.30 ------

0.78 4.614E-Ol ------

Line Not Found ------

1401.48 ------

1. 39 4.583E-01 ------

Line Not Found ------

1407.97 ------

2.48 4.571E-01 ------

Line Not Found ------

1509.22 ------

2.19 4.415E-Ol ------

Line Not Found ------

1583.22

0. 72 4.336E-01 Line Not Found ------

1661. 26 1.15 4.280E-01 Line Not Found ------

1729.58 ------

3.05 4.255E-01 ------

Line Not Found 1764.49 ------

15.90 4.249E-01 ------

Line Not Found ------

1847.41 ------

2.12 4.256E-01 ------

Line Not Found ------

PB-214 53.17 1.10 3.707E-01 ------

Line Not Found ------

74.81 6.52 1.233E+OO Line Not Found ------

77.11 ------

11. 00 1.319E+OO Line Not Found ------

87.19 ------

3.88 l.650E+OO Line Not Found ------

90.13 ------

1.15

1. 730E+OO Line Not Found ------

241. 92 ------

7.46 1.933E+OO Line Not Found ------

258.94 0.55 l.859E+OO Line Not Found ------

295.09 20 19.20*

1. 713E+OO 5.075E-07 5.384E-07 42.75 351. 87 41 37.10 1.514E+OO 6.179E-07 6.555E-07 20.57 785.83
1. 09 7.498E-01 ------

Line Not Found ------

839.00 0.59 7.038E-01 Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 1011 Acquisition date 10-JUN-2014 13:28:47 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error RA-226

81. 07 0.18 1.459E+OO Line Not Found ------

186.11 23 3.28*

2.179E+OO 2.717E-06 2.717E-06 42.04 AC-228

89. 96 ------

3.40

1. 726E+OO Line Not Found ------

93.35 ------

5.60

1. 811E+OO ------

Line Not Found ------

99.55 ------

1. 30
1. 943E+OO ------

Line Not Found ------

105.36 ------

2.00 2.042E+OO Line Not Found ------

108.99 ------

0.67 2.093E+OO Line Not Found ------

129.03 ------

2.90 2.254E+OO Line Not Found ------

153.89 ------

0.84 2.276E+OO Line Not Found ------

209.39 ------

4.10 2.079E+OO ------

Line Not Found ------

216.24 0.80 2.048E+OO Line Not Found ------

270.26 ------

3.80 l.812E+OO Line Not Found ------

328.07 ------

3.50 1.593E+OO Line Not Found ------

338.42 ------

12.40 1.558E+OO Line Not Found ------

340.94 ------

0.52 1.550E+OO Line Not Found ------

409.62 2.20 1.348E+OO Line Not Found ------

463.10 4.60 1.219E+OO Line Not Found ------

562.65 ------

1. 01 1.028E+OO Line Not Found ------

581. 52 3.00 9.978E-01 ------

Line Not Found ------

72 6. 63 0.87 8.087E-01 ------

Line Not Found ------

755.28

1. 32 7.791E-01 Line Not Found ------

772. 28

1. 09 7.625E-01 Line Not Found ------

782.12 0.59 7.532E-01 ------

Line Not Found ------

794.79 ------

4. 60 7.416E-01 ------

Line Not Found ------

830.59 ------

0.63 7.107E-01 ------

Line Not Found ------

835.60

1. 71 7.065E-01 ------

Line Not Found ------

840.44 0.94 7.026E-01 ------

Line Not Found ------

904.29 ------

0.89 6.549E-01 ------

Line Not Found ------

911.16 13 29.00*

6.501E-Ol 5.702E-07 5.727E-07

31. 57 964. 64 5.80 6.162E-01 Line Not Found ------

968.97 17.40 6.137E-01 Line Not Found ------

1246.60 ------

0.57 4.951E-01 ------

Line Not Found ------

1459.19 ------

1. 06 4.485E-01 ------

Line Not Found ------

1496.00 ------

1. 05 4.432E-01 ------

Line Not Found ------

1501. 44 0.58 4.425E-01 ------

Line Not Found ------

1580.30 ------

0. 71 4.338E-01 Line Not Found ------

1588.23 3.60 4.331E-01 Line Not Found ------

1630.47

1. 95 4.299E-Ol ------

Line Not Found ------

1638.10 ------

0.54 4.294E-01 ------

Line Not Found ------

U-235

89. 96 ------

3.36 1.726E+OO ------

Line Not Found ------

93.35 ------

5.50

1. 811E+OO Line Not Found ------

105.36 ------

1. 98 2.042E+OO Line Not Found ------

109.18 ------

1. 50
2. 096E+OO Line Not Found ------

143.79 ------

10.50 2.283E+OO Line Not Found ------

163.38 4.70 2.256E+OO Line Not Found ------

185.74 23 53.00*

2.179E+OO 1.682E-07 l.682E-07 44.01 194.96 ------

0.59 2.142E+OO ------

Line Not Found ------

202.13

1. 00
2. lllE+OO Line Not Found ------

205.33 4.70 2.097E+OO Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

7 Sample ID : 1011 Acquisition date 10-JUN-2014 13:28:47 Flag: "*"

Keyline

Minimum Detectable Activity Report Page :

8 Sample ID : 1011 Acquisition date 10-JUN-2014 13:28:47 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

7.

477.61 1.0196E-06 MN-54

4.

834.83 1.3763E-07 MN-56

5.

846.81 l.5907E-07 C0-57

18.

122.06 l.0102E-07 C0-58

3.

810.79

1. 2632E-07 C0-60
0.

1332.50 4.8612E-08 SB-124

2.

602.73 8.3534E-08 SB-125

5.

427.88 2.9630E-07 CS-134

2.

604.71 8.3958E-08 CS-137

2.

661. 66 l.0464E-07