Health Physics Sample Recorc;!s Sample ID:

142487 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 16, CAMP MESA 19 lcommoril Resp Org: P4000 - PROJECT MANAGEMEt

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

[_ Orlgin_l Mat. SizeNolume:

-1530 GRAMS

==

Description:==

CAMP MESA# 19 I Collectfonj

-~-

~

Sample Tech:

DYNES, WILLIAM J Tritium Req:

Yes Instructions:

COUNT TO MDA Comments:

COUNT TO MDA LR!,,§~l?J Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes

[Lof~tio_11_

Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 06/05/1411:32 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/03/1412:46 Sample SizeNolume: 1530 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

fv'"

Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Other:

Material Loe:

06/19/2014 07:34 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Health Physics Sample Records Sample ID:

142487 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

1406038D 16, CAMP MESA 19

~n_aJy~ls_j

~eo'!l.etry MCAID Quant.

Units Method

--*-------**----* --*-**--- -*-----~ ----

FP/AP Lab Analysis By B_1L_marinelli_sand -

30376 1530GR

.000 PARK, MICHAEL C

__ Isotope Mode _ Activity Activity Uncert.

LLD/MDA

%Abund.

Atom. No.

Comments 0

K-40 NT 0.00001424 1. 77E-6 r

73.444%

40 0

TL-208 NT 2.981E-7 1.062E-7 r

1.537%

208 0

PB-212 NT 7.451E-7 1.552E-7 3.843%

212 0

81-214 NT 8.047E-7 1.574E-7 4.150%

214 0

PB-214 NT 6.229E-7 1.438E-7 3.213%

214 0

RA-226 NT 2.522E-6 9.95E-7 r

13.007%

226 0

U-235 NT 1.561 E-7 6.16E-8 r

0.805%

235 0

BE-7 AP 1.0646E-6 Iv 0.000%

7 0

MN-54 AP 1.5434E-7 rv 0.000%

54 0

MN-56 AP 1.2948E-7 Iv 0.000%

56 0

C0-57 AP 9.4251E-8 Iv 0.000%

57 0

C0-58 AP 1.4665E-7 Iv 0.000%

58 0

C0-60 AP 1.4992E-7 iv 0.000%

60 0

SB-124 AP 8.2486E-8 Iv 0.000%

124 0

SB-125 FP 2.8742E-7 Iv 0.000%

125 0

CS-134 FP 1.1721 E-7 Iv 0.000%

134 0

CS-137 FP 1.4178E-7 Iv 0.000%

137 I Analysis -Review 1

_____________ _J Re-Analize:

No Lie Rad Mat Present:

No Reviewed: COOPER, TERRY L HP Notified Name:

Hp Eng Rvw Reqd:

Yes Comments:

06/19/2014 07:34 Rad Mat Present:

Yes Rasterized: r Date Mod ID Mod Date 06/05/14 16:28 Mod Id Mod Date Date: 06/10/1415:55 Page 2 of 3

Sample ID:

142487 Type: RLSSS Type Detail: SAND

==

Description:==

140603BD 16, CAMP MESA 19 L Review/ApproveJ Reviewed: COOPER, TERRY L Comments: U-235 is likely mis-lD'd off the Ra-226 peak Disposition: OTHER Remarks:

Health Physics Sample Record_~--

Status: APPROVED HP Review Date: 06/10/14 15:56 Disposition Result: Sample contains only natural isotopes FinalApproval _______________________ _

Approved: COOPER, TERRY L Date: 06/10/1415:56 Comments:

06/19/2014 07:34 Rasterized: r Page 3 of 3

SONGS HEALTH PHYSICS REPORT 5-JUN-2014 16:25

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140603BD 16, CAMP MESA 19

  • ID 30376 Acquisition date: 5-JUN-2014 16:22:08. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 5-JUN-2014 16:22:00.

5-JUN-2014 16:22:00.

Counting System l.53000E+03 GR IHPS Sample Number:

B lL marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142487 HP NATURAL

>>>>> B #42-TP11663A PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.46 0 00:03:00.50 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 5-JUN-2014 08:35:

-4. 96372E-01 5.00067E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left PW %Err Fit Nuclides 1

185.89 17 12

1. 58 372.73 369 7 39.4 3.03E+OO U-235 RA-226 1

238.65 60 23

1. 53 478.23 472 11 20.8 2.43E+OO PB-212 1

241.78 21 7

2.02 484.49 482 7 29.5 2.15E+OO PB-214 1

351.95 32 6

2.09 704.79 698 11 23.1 1.12E+OO PB-214 1

583.64 17 7

1. 56 1168.13 1163 9 35.6 2.95E-01 TL-208 1

609.53 32 3

2.09 1219.89 1215 10 19.6 3.62E-01 BI-214 1

1460.63 65 0

2.26 2921.94 2916 12 12.4 3.36E-01 K-40

Sununary of Nuclide Activity Sample ID : 30376 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :

2 5-JUN-2014 16:22:08 Number of lines tentatively identified by NID 7

0 7

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 1.28E+09Y

1. 00 l.424E-05
1. 424E-05 0.177E-05 12.43 A

TL-208 3.05M

1. 43 2.091E-07 2.981E-07 1.062E-07 35.63 A

PB-212 10.64H

1. 00 7.438E-07 7.451E-07 l.552E-07 20.83 A

BI-214 19.90M

1. 06 7.602E-07 8.047E-07 1.574E-07 19.56 A

PB-214

26. SOM
1. 04 5.971E-07 6.229E-07 l.438E-07 23.09 KA RA-226 1600.00Y
1. 00 2.522E-06 2.522E-06 0.995E-06 39.45 A

U-235 7.04E+08Y

1. 00
1. 561E-07 1.561E-07 0.616E-07
39. 45 A

Total Activity 1.923E-05 l.939E-05 Grand Total Activity :

1.923E-05 1.939E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30376 None Flags: "T" Tentatively associated Page :

3 Acquisition date 5-JUN-2014 16:22:08

Interference Report Sample ID : 30376 No interference correction performed Acquisition date Page :

4 5-JUN-2014 16:22:08

Nuclide Line Activity Report Page :

5 Sample ID : 30376 Acquisition date 5-JUN-2014 16:22:08 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 65 10.67*

4.212E-01 l.424E-05

1. 424E-05 12.43 TL-208 72.80 2.14 1.070E+OO Line Not Found ------

74.97 3.60 1.156E+OO Line Not Found ------

84.79 ------

1. 27 1.506E+OO Line Not Found ------

252.45 ------

0.80 l.745E+OO Line Not Found ------

277.28 6.80

1. 645E+OO Line Not Found ------

510.61 ------

21. 60
1. 035E+OO Line Not Found ------

583.02 17 86.00*

9.190E-01 2.091E-07 2.981E-07 35.63 763.06 ------

1. 64 7.126E-01 ------

Line Not Found ------

860.30 12.00 6.341E-01 ------

Line Not Found ------

PB-212 74.81 ------

10.50 1.150E+OO Line Not Found ------

77.11 17.70 1.239E+OO Line Not Found ------

87.19 ------

6.27 1.579E+OO Line Not Found ------

90.13 ------

1. 86 l.662E+OO Line Not Found ------

115. 12 0.59 2.085E+OO Line Not Found ------

238.58 60 43.60*

1. 804E+OO 7.438E-07
7. 451E-07 20.83 300.03 3.34 l.562E+OO Line Not Found ------

BI-214 76.86 ------

0.58

1. 229E+OO Line Not Found ------

79.29 ------

0.97 l.320E+OO Line Not Found ------

609.31 32 46.10*

8.830E-01 7.602E-07 8.047E-07 19.56 665.44

1. 56 8.131E-01 ------

Line Not Found ------

7 68. 35 4.88 7.078E-01 ------

Line Not Found ------

806.16 ------

1. 23 6.754E-01 ------

Line Not Found ------

934.04 3.16 5.861E..:.01 Line Not Found ------

11?.0. 27 15.00 4.982E-01 Line Not Found ------

1155.18

1. 69 4.860E-01 Line Not Found ------

1238.11 ------

5.92 4.615E-01 ------

Line Not Found ------

1280.95 ------

1. 47
4. 510E*-01 Line Not Found ------

1377. 66 4.02 4.323E-01 ------

Line Not Found ------

1385.30 ------

0.78

4. 311E-01 ------

Line Not Found ------

1401.48 ------

1. 39 4.287E-01 ------

Line Not Found ------

1407.97 2.48 4.277E-01 ------

Line Not Found ------

1509.22 ------

2.19 4.165E-01 Line Not Found ------

1583.22 ------

0. 72 4.120E-01 ------

Line Not Found ------

1661. 26 ------

1.15 4.103E-Ol Line Not Found ------

1729.58 ------

3.05 4.114E-01 ------

Line Not Found ------

1764.49 ------

15.90 4.128E-01 ------

Line Not Found ------

1847.41 ------

2.12 4.187E-01 ------

Line Not Found ------

PB-214 53.17 1.10 2.929E-01 ------

Line Not Found ------

74.81 6.52 1.150E+OO Line Not Found ------

77.11

11. 00 1.239E+OO Line Not Found ------

87.19 ------

3.88 1.579E+OO Line Not Found ------

90.13 1.15 l.662E+OO Line Not Found ------

241. 92 21 7.46 1.791E+OO l.558E-06 l.625E-06 29.47 258.94 0.55

1. 718E+OO Line Not Found ------

295.09 19.20*

l.579E+OO Line Not Found ------

351. 87 32 37.10 l.395E+OO 5.971E-07 6.229E-07 23.09 785.83

1. 09 6.925E-01 ------

Line Not Found ------

839.00 0.59 6.497E-01 ------

Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30376 Acquisition date 5-JUN-2014 16:22:08 Nuclide Type: natural Nuclide RA-226 U-235 Flag: "*"

Energy

81. 07 186.11
89. 96 93.35 105.36 109.18 143.79 163.38 185.74 194. 96 202.13 205.33 Keyline Area 17 17

%Abn

%Eff 0.18 1.383E+OO 3.28*

2.044E+OO 3.36 1.657E+OO 5.50 1.743E+OO

1. 98 l.973E+OO
1. 50 2.024E+OO 10.50 2.177E+OO 4.70 2.133E+OO 53.00*

2.044E+OO 0.59 2.003E+OO

1. 00
1. 970E+OO 4.70 l.956E+OO Uncorrected Decay Corr 1-Sigma uCi/GR uCi/GR

%Error Line Not Found ------

2.522E-06 2.522E-06 39.45 Line Not Found ------

Line Not Found ------

Line Not Found ------

Line Not Found ------

Line Not Found ------

Line Not Found ------

l.561E-07 1.561E-07 39.45 Line Not Found ------

Line Not Found ------

Line Not Found ------

Minimum Detectable Activity Report Page :

7 Sample ID 30376 Acquisition date 5-JUN-2014 16:22:08 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

4.

477.61 l.0646E-06 MN-54

3.

834.83 l.5434E-07 MN-56

1.

846.81 l.2948E-07 C0-57

10.

122.06 9.4251E-08 C0-58

2.

810.79 l.4665E-07 C0-60

1.

1332.50 1.4992E-07 SB-124

1.

602.73 8.2486E-08 SB-125

3.

427.88 2.8742E-07 CS-134

3.

604.71 1.1721E-07 CS-137

3.

661.66 1.4178E-07