ML20034E287

From kanterella
Jump to navigation Jump to search
Salvage 8-10 - Health Physics Sample Records
ML20034E287
Person / Time
Site: San Onofre  Southern California Edison icon.png
Issue date: 05/16/2016
From:
Southern California Edison Co
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20034D837 List: ... further results
References
Download: ML20034E287 (11)


Text


* Health Physics Sample Records Sample ID:

142481 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 10, CAMP MESA# 8

~_f!!m_prt_]

Resp Org: P4000 - PROJECT MANAGEMEr

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

I Origin __

Mat. SizeNolume:

1397 GRAMS

==

Description:==

CAMP MESA# 8 I CollectiC>l!J Sample Tech: DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA

_RLSSS _I Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes

_L,_o~c1~j-~n J Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 06/05/14 09:41 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/03/14 15:50 Sample SizeNolume: 1397 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

P' Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Other:

Material Loe:

06/19/2014 06:51 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

H_ealth Physics Sample R~cor_d_s ______ _____ _

Sample ID:

142481 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 10, CAMP MESA# 8

[Analysis j Geometry ---~-

MCA ID Quant.

Units Method FP/AP A_1L_marinelli_sand_

30363 1397GR

.000 Isotope Mode_ Activity Activity Uncert.

LLD/MDA

%Abund.


~

0 K-40 NT 0.000013871.76E-6 0

TL-208 NT 3.681E-7 9.26E-8 0

PB-212 NT 7.591E-7 1.113E-7 0

Bl-214 NT 7.217E-7 1.376E-7 0

PB-214 NT 9.641E-7 2.429E-7 0

RA-224 NT 1.912E-6 8.38E-7 0

RA-226 NT 2.655E-6 1.175E-6 0

AC-228 NT 1.129E-6 2.99E-7 0

U-235 NT 1.643E-7 7.27E-8 0

BE-7 AP 1.1386E-6 0

MN-54 AP 9.8547E-8 0

MN-56 AP 1.4405E-7 0

C0-57 AP 8.216E-8 0

C0-58 AP 1.5683E-7 0

C0-60 AP 5.2945E-8 0

SB-124 AP 7.4625E-8 0

SB-125 FP 3.5808E-7 0

CS-134 FP 1.0828E-7 0

CS-137 FP 1.0056E-7

!. Analysis Review j Re-Analize:

No Hp Eng Rvw Reqd:

Yes Comments:

06/19/2014 06:51 r r r r r Iv Iv Iv Iv Iv Iv Iv w Iv Iv 61.526%

1.633%

3.367%

3.201%

4.277%

8.481%

11.777%

5.008%

0.729%

0.000%

0.000%

0.000%

0.000%

0.000%

0.000%

0.000%

0.000%

0.000%

0.000%

Lie Rad Mat Present:

No Rad Mat Present:

Yes Atom. No.

40 208 212 214 214 224 226 228 235 7

54 56 57 58 60 124 125 134 137 Lab Analysis By PARK, MICHAEL C Comments Reviewed: COOPER, TERRY L HP Notified Name:

Date 06/05/14 15:43 Rasterized: r Mod ID Mod Date Mod Id Mod Date Date: 06/10/14 14:54 Page 2 of 3

Health Physics Samp_le_R_e_c_o_rd_s _____ _

Sample ID:

142481 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140603BD 10, CAMP MESA# 8 Review/Approve l HP Review Reviewed: COOPER, TERRY L Date: 06/10/1414:55 Comments: U-235 is likely mis-lD'd off the Ra-226 peak Disposition Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/19/2014 06:51 Result: Sample contains only natural isotopes Final Approval Date: 06/10/1414:55 Rasterized: r Page 3 of 3

SONGS HEALTH PHYSICS REPORT 5-JUN-2014 15:39

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140603BD 10, CAMP MESA# 8

  • ID 30363 Acquisition date: 5-JUN-2014 15:36:24. *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry 5-JUN-2014 15:36:00.

5-JUN-2014 15:36:00.

Counting System 1.39700E+03 GR IHPS Sample Number:

A lL marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142481 HP NATURAL

>>>>> A #41-TP11679B PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.41 0 00:03:00.46 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 5-JUN-2014 08:09:

2.12659E-01 4.99528E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

77.07 40 34 0.99 153.86 151 7 30.2 3.92E-01 BI-214 PB-212 PB-214 1

186.04 19 21

1. 69 372. 01 369 7 44.3 3.43E+OO U-235 RA-226 1

238.51 64 9

0.87 477.04 474 6 14.7 1.55E+OO PB-212 1

241. 38 14 12

1. 30 482.78 481 6 43.8 1.32E+OO RA-224 PB-214 1

295.32 30 6

1. 51 590.77 587 10 25.2 9.36E-01 PB-214 1

338.15 18 4

1. 86 676.51 673 7 27.2 4.37E-01 AC-228 1

351.93 41 7

1. 38 704.10 699 9 19.6 1. 61E+OO PB-214 1

462.75 17 8

2.64 925. 96 922 10 36.2 9.82E-01 AC-228 1

583.08 22 3

2.07 1166. 84 1160 11 25.1 2.17E-01 TL-208 1

609.27 31 2

1. 4 9 1219.27 1215 8 19.1 1. 55E-01 BI-214 1

910.88 22 4

1. 55 1823.06 1818 9 26.5 4.17E-01 AC-228 1

1460.62 73 3

1. 72 2923.58 2917 12 12.7 9.03E-01 K-40

Summary of Nuclide Activity Sample ID : 30363 Acquisition date Page :

2 5-JUN-2014 15:36:24 Total number of lines in spectrum 12 Number of unidentified lines 0

Number of lines tentatively identified by NID 12 100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 l.28E+09Y

1. 00 l.387E-05 l.387E-05 0.176E-05 12.72 A

TL-208 3.05M

1. 52 2.430E-07 3.681E-07 0.926E-07 25.15 A

PB-212 10.64H

1. 00 7.576E-07 7.591E-07 l.113E-07 14.66 A

BI-214 19.90M

1. 07 6.754E-07 7.217E-07 l.376E-07 19.06 A

PB-214 26.SOM

1. 05 9.178E-07 9.641E-07 2.429E-07 25.19 A

RA-224 3.66D

1. 00
1. 912E-06 l.912E-06 0.838E-06 43.82 A

RA-226 1600.00Y

1. 00 2.655E-06 2.655E-06 l.175E-06 44.26 A

AC-228 6.13H

1. 00 l.125E-06 l.129E-06 0.299E-06 26.49 A

U-235 7.04E+08Y

1. 00 l.643E-07
1. 643E-07 0.727E-07 44.26 A

Total Activity 2.232E-05 2.254E-05 Grand Total Activity :

2.232E-05 2.254E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30363 None Flags: "T" Tentatively associated Page :

3 Acquisition date 5-JUN-2014 15:36:24

Interference Report Sample ID : 30363 No interference correction performed Acquisition date Page :

4 5-JUN-2014 15:36:24

Nuclide Line Activity Report Page :

5 Sample ID : 30363 Acquisition date 5-JUN-2014 15:36:24 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 73 10.67*

5.314E-01 1.387E-05 l.387E-05 12.72 TL-208 72.80 2.14 l.594E+OO Line Not Found ------

74.97 3.60 l.692E+OO Line Not Found ------

84.79

1. 27 2.058E+OO Line Not Found ------

252.45 0.80 2.021E+OO Line Not Found ------

277.28 6.80 1.920E+OO Line Not Found ------

510.61 ------

21. 60 l.265E+OO Line Not Found ------

583.02 22 86.00*

l.128E+OO 2.430E-07 3.681E-07 25.15 763.06

1. 64 8.744E-01 Line Not Found ------

860.30 ------

12.00 7.770E-Ol Line Not Found ------

PB-212 74.81 10.50 l.685E+OO Line Not Found ------

77.11 40 17.70 l.781E+OO

1. 344E-06 1.347E-06 30.20 87.19 ------

6.27 2.l29E+OO Line Not Found ------

90.13

1. 86 2.206E+OO Line Not Found ------

115.12 0.59 2.535E+OO Line Not Found ------

238.58 64 43.60*

2.083E+OO 7.576E-07 7.591E-07 14.66 300.03 ------

3.34 l.834E+OO ------

Line Not Found ------

BI-214 76.86 40 0.58 l.781E+OO 4.l03E-05 4.383E-05 30.20 79.29 0.97 l.869E+OO Line Not Found ------

609.31 31 46.10*

1. 084E+OO 6.754E-07 7.217E-07 19.06 665.44
1. 56 9.985E-Ol Line Not Found ------

768.35 4.88 8.685E-01 Line Not Found ------

806.16 ------

1. 23 8.283E-Ol Line Not Found ------

934.04 3.16 7.177E-01 Line Not Found ------

1120.27 15.00 6.114E-01 ------

Line Not Found ------

1155.18 ------

1. 69 5.973E-Ol Line Not Found ------

1238.11 ------

5.92 5.697E-01 Line Not Found ------

1280.95 ------

1. 47 5.585E-Ol Line Not Found ------

1377.66 4.02 5.401E-Ol Line Not Found ------

1385. 30 0.78 5.391E-Ol Line Not Found ------

1401.48

1. 39 5.370E-Ol Line Not Found ------

1407.97 2.48 5.362E-Ol Line Not Found ------

1509.22 2.19 5.292E-01 Line Not Found ------

1583.22

0. 72
5. 296E-Ol Line Not Found ------

1661.26 1.15 5.351E-Ol Line Not Found ------

1729.58 3.05 5.442E-01 Line Not Found ------

1764.49 ------

15.90 5.503E-Ol Line Not Found ------

1847.41 ------

2.12 5.694E-Ol Line Not Found ------

PB-214 53.17 1.10 5.543E-Ol Line Not Found ------

74.81 6.52 l.685E+OO Line Not Found ------

77.11 40

11. 00 l.781E+OO 2.l63E-06 2.272E-06 30.20 87.19 ------

3.88 2.129E+OO Line Not Found ------

90.13 1.15 2.206E+OO Line Not Found ------

241. 92 14 7.46 2.070E+OO 9.993E-07 l.050E-06 43.82 258.94 ------

0.55

1. 994E+OO Line Not Found ------

295.09 30 19.20*

l.851E+OO 9.l78E-07

9. 641E-07 25.19 351.87 41 37.10 l.662E+OO 7.l82E-07 7.545E-07 19.55 785.83
1. 09 8.495E-01 Line Not Found ------

839.00 0.59

7. 964E-Ol Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30363 Acquisition date 5-JUN-2014 15:36:24 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error RA-224 83.79 ------

0.20 2.027E+OO Line Not Found ------

240.76 14 3.90*

2.070E+OO 1.912E-06

1. 912E-06 43.82 RA-226
81. 07 0.18
1. 934E+OO Line Not Found ------

186.11 19 3.28*

2.339E+OO 2.655E-06 2.655E-06 44.26 AC-228

89. 96 3.40 2.201E+OO Line Not Found ------

93.35 ------

5.60 2.279E+OO Line Not Found ------

99.55

1. 30 2.389E+OO Line Not Found ------

105.36 ------

2.00 2.463E+OO Line Not Found ------

108.99 ------

0.67

2. 4 96E+OO Line Not Found ------

129.03 ------

2.90 2.562E+OO Line Not Found ------

153.89 ------

0.84

2. 4 96E+OO Line Not Found ------

209.39 ------

4.10 2.221E+OO Line Not Found ------

216.24 0.80 2.187E+OO ------

Line Not Found ------

270.26 ------

3.80 l.948E+OO Line Not Found ------

328.07 ------

3.50

1. 738E+OO Line Not Found ------

338.42 18 12.40 1.705E+OO 9.350E-07 9.384E-07 27.19 340.94 0.52 1.696E+OO Line Not Found ------

409.62 2.20 l.499E+OO Line Not Found ------

463.10 17 4.60 l.368E+OO 2.895E-06 2.905E-06 36.16 562.65 ------

1. 01 1.164E+OO Line Not Found ------

581.52 ------

3.00 1.131E+OO Line Not Found ------

72 6. 63 0.87 9.173E-Ol ------

Line Not Found ------

755.28

1. 32 8.833E-01 ------

Line Not Found ------

772.28

1. 09
8. 641E-01 Line Not Found ------

782.12 0.59 8.534E-01 ------

Line Not-Found ------

794.79 4.60 8.400E-01 Line Not Found ------

830.59 ------

0.63 8.043E-01 ------

Line Not Found ------

835.60

1. 71
7. 996E-01 Line Not Found ------

840.44 0.94 7.951E-01 ------

Line Not Found ------

904.29 ------

0.89 7.403E-01 ------

Line Not Found ------

911.16 22 29.00*

7.351E-01 1.125E-06 l.129E-06

26. 4 9 964. 64 5.80
6. 962E-01 Line Not Found ------

968.97 17.40 6.933E-01 Line Not Found ------

1246.60 ------

0.57 5.673E-01 Line Not Found ------

1459.19 ------

1. 06 5.315E-01 Line Not Found ------

1496.00 ------

1. 05 5.296E-01 ------

Line Not Found ------

1501.44 0.58 5.294E-01 ------

Line Not Found ------

1580.30 ------

0.71 5.295E-01 ------

Line Not Found ------

1588.23 ------

3.60 5.298E-01 ------

Line Not Found ------

1630.47

1. 95 5.324E-01 Line Not Found 1638.10 ------

0.54 5.330E-01 Line Not Found ------

U-235

89. 96 3.36 2.201E+OO Line Not Found 93.35 ------

5.50

2. 27 9E+OO Line Not Found ------

105.36 ------

1. 98 2.463E+OO Line Not Found ------

109.18 ------

1. 50 2.498E+OO Line Not Found ------

143.79 ------

10.50 2.533E+OO Line Not Found ------

163.38 ------

4.70 2.453E+OO Line Not Found ------

185.74 19 53.00*

2.339E+OO 1.643E-07

1. 643E-07 44.26 194. 96 0.59 2.294E+OO Line Not Found ------

I Nuclide Line Activity Report (continued)

Sample ID : 30363 Acquisition date Page :

7 5-JUN-2014 15:36:24 Nuclide Type: natural Nuclide Flag: "*"

Energy 202.13 205.33 Keyline Area

%Abn

1. 00 4.70

%Eff 2.257E+OO 2.241E+OO Uncorrected Decay Corr uCi/GR uCi/GR Line Not Found Line Not Found 1-Sigma

%Error

Minimum Detectable Activity Report Page :

8 Sample ID 30363 Acquisition date 5*-JUN-2014 15:36:24 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

7.

477.61 1.1386E-06 MN-54

1.

834.83 9.8547E-08 MN-56

3.

846.81 1.4405E-07 C0-57

9.

122.06 8.2160E-08 C0-58

4.

810.79

1. 5683E-07 C0-60
0.

1332. 50 5.2945E-08 SB-124

1.

602.73 7.4625E-08 SB-125

6.

427.88 3.5808E-07 CS-134

3.

604. 71 1.0828E-07 CS-137

1.

661.66 1.0056E-07