Health Physics Sample Records Sample ID:

142522 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140528BD 03 STAR YARD# 3-20

[Common]

Resp Org: P4000 - PROJECT MANAGEMEr

Contact:

COOPER, TERRY L Reference ID: 142432 Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments: COUNT TO MDA I Or!Qin Mat. SizeNolume:

1816 GRAMS

==

Description:==

STAR YARD# 3 Collection Sample Tech:

DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA RLSSS)

Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes I Location Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 06/11/1410:33 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 05/23/1412:48 Sample SizeNolume: 1816 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

~

Unit: NON-UNIT RE Stored By:.

Sample Loe:

Area: MS Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Other: COUNT TO MDA Material Loe:

06/18/2014 12:45 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

Health Physics Sample Records Sample ID:

142522 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

1405288D 03 STAR YARD# 3-20

[Analysis [

Geometry MCAID Quant.

Units Method FP/AP A_1L_marinelli_sand -

1015 1000 gr

.000 Isotope Mode Activity Activity Uncert.

LLD/MDA

%Abund.

Atom. No.

0 BE-7 AP 1.393E-6 4.11E-7 r

7.760%

7 0

K-40 NT 0.0000109 1.22E-6 r

60.722%

40 0

TL-208 NT 4.929E-7 1.119E-7 r

2.746%

208 0

PB-212 NT 6.869E-7 1.014E-7 r

3.827%

212 0

81-214 NT 6.623E-7 1.248E-7 r

3.690%

214 0

PB-214 NT 4.85E-7 2.183E-7 r

2.702%

214 0

RA-226 NT 2.663E-6 8.27E-7 r

14.835%

226 0

AC-228 NT 5.029E-7 3.466E-7 r

2.802%

228 0

U-235 NT 1.648E-7 5.55E-8 r

0.918%

235 0

MN-54 AP 7.4934E-8 jv 0.000%

54 0

MN-56 AP 2.2478E-8 IV 0.000%

56 0

C0-57 AP 7.6585E-8 IV 0.000%

57 0

C0-58 AP 1.0182E-7 w

0.000%

58 0

C0-60 AP 1.1046E-7 jv 0.000%

60 0

SB-124 AP 7.1267E-8 jv 0.000%

124 0

SB-125 FP 1.8533E-7 jv 0.000%

125 0

CS-134 FP 1.1345E-7 jv 0.000%

134 0

CS-137 FP 1.7609E-7 IV 0.000%

137 Analysis Review Re-Analize:

No Lie Rad Mat Present:

No Hp Eng Rvw Reqd:

Yes Rad Mat Present:

Yes Comments: This is a replacement for ID# 142432 that had error in description (2-20 vs: 3-20) 06/18/2014 12:45 Lab Analysis By DYNES, WILLIAM J Comments Reviewed: COOPER, TERRY L HP Notified Name:

Rasterized: r Date Mod ID Mod Date 06/11 /14 14:03 Mod Id Mod Date Date: 06/17/14 13:53 Page 2 of 3

Health Physics Sample Records Sample ID:

142522 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140528BD 03 STAR YARD# 3-20 r Review/Approve I HP Eng Review Reviewed: COOPER, TERRY L Date: 06/17/1413:54 Comments: U-235 likely mis-lD'd off Ra-226 energy peak. Be-7 is a natural product coming from cosmic ray interaction.

Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/18/2014 12:45 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/17/14 13:54 Rasterized: r Page 3 of 3

SONGS HEALTH PHYSICS REPORT ll-JUN-2014 10:54

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140528BD 03 STAR YARD# 3-20

  • ID 1013 Acquisition date: ll-JUN-2014 10:51:47 *
  • Start Time:
  • Stop Time:
  • Quantity
  • Geometry ll-JUN-2014 10:51:00 ll-JUN-2014 10:51:00 l.81600E+03 GR A lL marinelli sand 1 Operator: BILL Counting System IHPS Sample Number:

Analysis Library DYNES UlGSP 142522 HP NATURAL

>>>>> A -1922924

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.29 0 00:03:00.36 0.0%

1.00000E+OO 8.00000 PARAMETERS<<<<<

Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity ll-JUN-2014 09:11

-l.07429E-01 4.99821E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

239.07 54 23

1. 59 478.50 472 15 24.7 2.91E+OO PB-212 1

295.04 17 13

1. 96 590.47 585 10 43.2 2.50E+OO PB-214 1

338.58 25 5

3.64 677.58 672 9 22.7 7.39E-01 1

352.00 34 6

2. 60 704.42 697 11 21.1 1.12E+OO PB-214 1

583.53 15 4

1. 68 1167.57 1163 8 34.0 1.93E-01 TL-208 1

609.39 21 2

1. 91 1219.29 1214 10 25.9 5.44E-01 BI-214 1

1460.69 57 0

2.11 2921.85 2916 11 13.1 4.46E-01 K-40

Summary of Nuclide Activity Sample ID : 1013 Total number of lines in spectrum Number of unidentified lines Page :

2 Acquisition date ll-JUN-2014 10:51:47 Number of lines tentatively identified by NID 7

0 7

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 1.28E+09Y

1. 00 9.827E-06 9.827E-06 l.338E-06 13.62 A

TL-208 3.05M

1. 65 1.421E-07 2.342E-07 0.807E-07 34.44 A

PB-212 10.64H

1. 00 5.245E-07 5.258E-07 1.318E-07 25.07 A

BI-214 19.90M

1. 08 3.845E-07 4.162E-07 1.093E-07
26. 25 A

PB-214

26. SOM
1. 06 4.355E-07 4.620E-07 2.00SE-07 43.41 A

Total Activity l.131E-05 1.14 7E-05 Grand Total Activity :

l.131E-05 1.147E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 1013 Page :

3 Acquisition date : ll-JUN-2014 10:51:47 It 1

Energy Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err

%Eff Flags 338.58 25 5

3.64 677.58 672 9 1.39E-01 22.7 1.56E+OO T

Flags: "T" = Tentatively associated

Interference Report Sample ID : 1013 No interference correction performed Page :

4 Acquisition date 11-JON-2014 10:51:47

Nuclide Line Activity Report Page :

5 Sample ID : 1013 Acquisition date ll-JUN-2014 10:51:47 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 57 10.67*

4.483E-01 9.827E-06 9.827E-06 13.62 TL-208 72.80 2.14 1.155E+OO ------

Line Not Found ------

74.97 3.60 1.239E+OO ------

Line Not Found ------

84.79


~-

1. 27 l.578E+OO Line Not Found ------

252.45 ------

0.80

1. 887E+OO Line Not Found ------

277.28 ------

6.80 1.783E+OO Line Not Found ------

510.61 ------

21. 60 1.121E+OO ------

Line Not Found ------

583.02 15 86.00*

9.946E-01 l.421E-07 2.342E-07 34.44 763.06 ------

1. 64 7.714E-Ol ------

Line Not Found ------

860.30 12.00 6.870E-01 ------

Line Not Found ------

PB-212 74.81 10.50 1.233E+OO ------

Line Not Found ------

77.11 ------

17.70 l.319E+OO Line Not Found ------

87.19 ------

6.27 1.650E+OO Line Not Found ------

90.13

1. 86 1.730E+OO Line Not Found ------

115. 12 0.59 2.162E+OO Line Not Found ------

238.58 54 43.60*

l.946E+OO 5.245E-07 5.258E-07 25.07 300.03 ------

3.34 1.694E+OO ------

Line Not Found ------

BI-214 76.86 ------

0.58 1.310E+OO ------

Line Not Found ------

79.29 0.97 l.397E+OO Line Not Found ------

609.31 21 46.10*

9.556E-01 3.845E-07 4.162E-07 26.25 665.44

1. 56 8.797E-01 ------

Line Not Found ------

768.35 ------

4.88 7.663E-01 ------

Line Not Found ------

806.16 ------

1. 23 7.315E-01 ------

Line Not Found ------

934.04 3.16 6.352E-01 Line Not Found ------

1120.27 15.00 5.391E-01 Line Not Found ------

1155. 18 ------

1. 69 5.255E-01 ------

Line Not Found ------

1238.11 ------

5.92 4.976E-01 ------

Line Not Found ------

1280.95 ------

1. 4 7 4.855E-Ol ------

Line Not Found ------

1377. 66 ------

4.02 4.629E-01 ------

Line Not Found ------

1385. 30 0.78 4.614E-01 ------

Line Not Found ------

1401. 48

1. 39 4.583E-01 ------

Line Not Found ------

1407.97 2.48 4.571E-01 Line Not Found ------

1509.22 ------

2.19 4.415E-01 Line Not Found ------

1583.22 ------

0.72 4.336E-01 Line Not Found ------

1661. 26 1.15 4.280E-01 Line Not Found ------

1729.58 ------

3.05 4.255E-01 Line Not Found ------

1764.49 ------

15.90 4.249E-01 ------

Line Not Found ------

1847.41 ------

2.12 4.256E-01 ------

Line Not Found ------

PB-214 53.17 1.10 3.707E-01 ------

Line Not Found ------

74.81 ------

6.52 1.233E+OO ------

Line Not Found ------

77.11

11. 00 1.319E+OO

'Line Not Found ------

87.19 ------

3.88 1.650E+OO Line Not Found ------

90.13 1.15 1.730E+OO Line Not Found ------

241. 92 7.46 1.933E+OO Line Not Found 258.94 0.55 l.859E+OO Line Not Found ------

295.09 17 19.20*

1.713E+OO 4.355E-07 4.620E-07 43.41 351. 87 34 37.10 l.514E+OO 5.067E-07 5.375E-07

21. 59 785.83
1. 09 7.498E-01 ------

Line Not Found ------

839.00 ------

0.59 7.038E-01 ------

Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 1013 Acquisition date ll-JUN-2014 10:51:47 Flag: "*"

Keyline

Minimum Detectable Activity Report Page :

7 Sample ID : 1013 Acquisition date 11-JUN-2014 10:51:47 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

2.

477.61 6.2063E-07 MN-54

3.

834.83

1. 2560E-07 MN-56
3.

846.81 l.3004E-07 C0-57

14.

122.06 8.6879E-08 C0-58

2.

810.79 l.0032E-07 C0-60

0.

1332. 50 4.7212E-08 SB-124

3.

602.73 9.0270E-08 SB-125

6.

427.88 2.9730E-07 CS-134

2.

604. 71 8.1541E-08 CS-137

1.

661. 66 6.8019E-08