Sample ID:
142444 Type: RLSSS Type Detail: SAND
==
Description:==
140528BD 14 STAR 14-20 Dirt Sample Common Resp Org: P4000 - PROJECT MANAGEMEr
Contact:
COOPER, TERRY L Reference ID:
Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:
I Origin Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Unknown Mat:
NO Date: 05/30/14 08:14 Mat. SizeNolume:
1875 GRAMS Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00
==
Description:==
STAR 14 SOIL SAMPLE I Collection I Sample Tech: DYNES, WILLIAM J Tritium Req:
No Instructions:
Comments:
COUNT TO MDA I R1..sss 1 Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
Yes I Location Unit: NON-UNIT RE Stored By:,
Sample Loe:
Other:
Material Loe:
06/18/2014 11 :53 Area: MS Sample Date: 05/29/14 07:32 Sample SizeNolume: 1875 GRAMS Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
~
Elev: 100 Room:
Depth: 3" (in.)
Equip ID:
Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of 3
Health Physics Sample Records Sample ID:
142444 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140528BD 14 STAR 14-20 Dirt Sample
!Analysis I Geometry MCAID Quant.
Units Method FP/AP Lab Analysis By C_ 1 L_marinelli_sand_
30284 1875GR
.000 HENDERSON, JOE C Isotope Mode Activity Activity Uncert.
LLD/MDA
%Abund.
Atom. No.
Comments 0
K-40 NT 0.000014811.41E-6 6.806%
40 0
TL-208 NT 5.339E-7 8.42E-8 r
0.245%
208 0
PB-212 NT 9.109E-7 1.208E-7 r
0.419%
212 0
Bl-214 NT 7.262E-7 1.293E-7 r
0.334%
214 0
PB-214 NT 6.701E-7 2.376E-7 r
0.308%
214 0
RN-222 NT 0.0001961 0.0000521 r
90.120%
222 0
RA-226 NT 2.897E-6 1.209E-6 r
1.331%
226 0
AC-228 NT 7.712E-7 2.023E-7 r
0.354%
228 0
U-235 NT 1.793E-7 7.48E-8 r
0.082%
235 0
BE-7 AP 7.3754E-7 Iv 0.000%
7 0
54 0
MN-56 AP 1.0017E-7 Iv 0.000%
56 0
C0-57 AP 1.0125E-7 Iv' 0.000%
57 0
C0-58 AP 1.1466E-7 Iv 0.000%
58 0
C0-60 AP 1.2286E-7 Iv 0.000%
60 0
SB-124 AP 9.3833E-8 Iv 0.000%
124 0
SB-125 FP 2.1966E-7 Iv 0.000%
125 0
CS-134 FP 8.0324E-8 Iv 0.000%
134 0
137 I.A.na1ysis Review I Re-Analize:
No Lie Rad Mat Present:
No Reviewed: COOPER, TERRY L HP Notified Name:
Hp Eng Rvw Reqd:
Yes Comments:
06/18/201411:53 Rad Mat Present:
Yes Rasterized: r Date Mod ID Mod Date 05/30/1413:28 Mod Id Mod Date Date: 06/10/1410:03 Page 2 of 3
Health Physics Sample Records Sample ID:
142444 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140528BD 14 STAR 14-20 Dirt Sample I Review/ApproveJ HP Review Reviewed: COOPER, TERRY L Date: 06/10/14 10:04 Comments: U-235 likely mis-lD'd from Ac-228 and Ra-226 energy peaks Disposition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/18/201411:53 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/10/14 10:04 Rasterized: r Page 3 of 3
SONGS HEALTH PHYSICS REPORT 30-MAY-2014 13:16
- Title
>>>>> SAMPLE PARAMETERS<<<<<
140528BD 14 STAR 14-20 DIRT SAMrLE
- ID
- Start Time:
- Stop Time:
- Quantity 30284 30-MAY-2014 13:13:00 30-MAY-2014 13:13:00 l.87500E+03 GR Acquisition date: 30-MAY-2014 13:13:36 *
- Geometry C 11 marinelli sand 1 Operator: JOE Counting System IHPS Sample Number:
Analysis Library HENDERSON U2GSP 142444 HP NATURAL
>>>>> C #41-TP11750A PARAMETERS<<<<<
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.41 0 00:03:00.48 0.0%
1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 29-MAY-2014 21:45
-l.13380E-01 4.99622E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 5
74.34 70 24
- 1. 43 149.02 144 19 18.5 2.69E+OO PB-212 PB-214 TL-208 5
77.33 62 21
- 1. 43 155.01 144 19 21. 0 BI-214 PB-212 PB-214 1
93.18 46 42
- 1. 78 186.73 182 9 28.6 3.97E+OO AC-228 U-235 1
185.85 27 34
238.51 102 24 1.15 477.58 474 7 13. 3 5.67E+OO PB-212 1
295.28 28 16
- 1. 31 591.19 586 11 35.5 8.75E-01 PB-214 1
338.19 25 5
- 1. 50 677.08 670 11 27.7 8.97E-01 AC-228 1
351. 80 63 13
- 1. 53 704.31 700 9 16.3 5.47E-01 PB-214 1
510.54 22 5
2.50 1021.97 1018 9 26. 6 8.36E-01 RN-222 TL-208 1
582.98 42 0
- 1. 97 1166.93 1162 10 15.8 8.79E-01 TL-208 1
609.27 43 5
- 1. 91 1219.53 1214 10 17.8 5.09E-01 BI-214 1
910. 96 21 4
2.08 1823.18 1819 8 26.2 4.05E-01 AC-228 1
1460.72 110 0
2.04 2923.02 2918 10 9.5 4.57E-01 K-40
Summary of Nuclide Activity Sample ID : 30284 Total number of lines in spectrum Number of unidentified lines Acquisition date 13 0
Page :
2 30-MAY-2014 13:13:36 Number of lines tentatively identified by NID 13 Nuclide Type : natural 100.00%
Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error Flags K-40 1.28E+09Y
- 1. 00 1.481E-05
- 1. 481E-05 0.141E-05 9.50 A
TL-208 3.05M
- 1. 58 3.375E-07 5.339E-07 0.842E-07 15.77 A
PB-212 10.64H
- 1. 00 9.088E-07 9.109E-07 1.208E-07 13.27 A
BI-214 19.90M
- 1. 08 6.752E-07 7.262E-07 1.293E-07 17.81 A
PB-214 26.80M
- 1. 06 6.348E-07 6.701E-07 2.376E-07 35.45 A
RN-222 3.83D
- 1. 00
- 1. 960E-04 l.961E-04 0.521E-04 26.59 A
RA-226 1600.00Y
- 1. 00 2.897E-06 2.897E-06 1.209E-06
- 41. 73 A
AC-228 6.13H
- 1. 00 7.682E-07 7.712E-07 2.023E-07 26.23 A
U-235 7.04E+08Y
- 1. 00
- 1. 7 93E-07 1.793E-07 0.748E-07
- 41. 73 A
Total Activity 2.172E-04 2.176E-04 Grand Total Activity :
2.172E-04 2.176E-04 Flags: "K" Keyline not found "M"
Manually accepted "E"
Manually edited "A"
Nuclide specific abn. limit
Unidentified Energy Lines Sample ID : 30284 None Flags: "T" Tentatively associated Page :
3 Acquisition date 30-MAY-2014 13:13:36
Interference Report Sample ID : 30284 No interference correction performed Acquisition date Page :
4 30-MAY-2014 13:13:36
Nuclide Line Activity Report Page :
5 Sample ID : 30284 Acquisition date 30-MAY-2014 13:13:36 Nuclide Type: natural Uncorrected Decay Corr l-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 110 10.67*
5.560E-Ol l.481E-05
- l. 48lE-05 9.50 TL-208 72.80 2.14 l.486E+OO Line Not Found ------
74.97 70 3.60 l.551E+OO l.006E-05 l.592E-05 18.47 84.79 ------
- l. 27 l.917E+OO Line Not Found ------
252.45 ------
0.80 2.004E+OO Line Not Found ------
277.28 6.80
- l. 9l 7E+OO Line Not Found ------
510.61 22
- 21. 60
- l. 298E+OO 6.353E-07 l.005E-06 26.59 583.02 42 86.00*
- l. l58E+OO 3.375E-07 5.339E-07 15.77 763.06 ------
- l. 64 8.934E-Ol ------
Line Not Found ------
860.30 ------
12.00 7.922E-Ol ------
Line Not Found ------
PB-212 74.81 70 10.50
- l. 551E+OO 3.450E-06 3.458E-06 18.47 77.11 62 17.70 1.669E+OO l.684E-06
- l. 688E-06
- 21. 04 87.19 ------
6.27 1.983E+OO Line Not Found ------
90.13 ------
- l. 86 2.055E+OO Line Not Found ------
115.12 ------
0.59 2.376E+OO Line Not Found ------
238.58 102 43.60*
2.055E+OO 9.088E-07 9.l09E-07 13.27 300.03 ------
3.34 l.843E+OO ------
Line Not Found ------
BI-214 76.86 62 0.58 l.669E+OO 5.l39E-05 5.527E-05
- 21. 04 79.29 ------
0.97 l.741E+OO Line Not Found ------
609.31 43 46.10*
- l. 112E+OO 6.752E-07 7.262E-07 17.81 665.44
- l. 56 1.023E+OO Line Not Found ------
768.35 ------
4.88 8.873E-Ol Line Not Found ------
806.16 ------
- l. 23 8.454E-Ol Line Not Found ------
934.04 ------
3.16 7.3l0E-Ol ------
Line Not Found ------
1120. 27 15.00 6.242E-01 ------
Line Not Found 1155. 18
- l. 69 6.105E-Ol ------
Line Not Found ------
1238.11 ------
5.92 5.846E-Ol ------
Line Not Found ------
1280.95 ------
- l. 4 7 5.747E-01 ------
Line Not Found ------
1377. 66 ------
4.02 5.602E-01 ------
Line Not Found ------
1385.30 ------
0.78 5.595E-Ol ------
Line Not Found ------
1401.48 ------
- l. 39 5.583E-Ol ------
Line Not Found ------
1407.97 ------
2.48 5.578E-Ol Line Not Found ------
1509.22 ------
2.19 5.568E-Ol ------
Line Not Found ------
1583.22
- 0. 72 5.628E-Ol Line Not Found ------
1661. 26 l.15 5.753E-Ol ------
Line Not Found ------
1729.58 ------
3.05 5.918E-Ol Line Not Found ------
1764.49 ------
15.90 6.023E-01 Line Not Found ------
1847.41 ------
2.12 6.331E-Ol ------
Line Not Found ------
PB-214 53.17 l.10 5.203E-Ol ------
Line Not Found ------
74.81 70 6.52 l.551E+OO 5.556E-06 5.865E-06 18.47 77.11 62
- 11. 00 l.669E+OO 2.709E-06 2.860E-06
- 21. 04 87.19 ------
3.88
- 1. 983E+OO Line Not Found ------
90.13 l.15 2.055E+OO Line Not Found ------
241. 92 7.46 2.043E+OO Line Not Found ------
258.94 0.55 l.981E+OO Line Not Found ------
295.09 28 19.20*
1.858E+OO 6.348E-07 6.701E-07 35.45 351. 87 63 37.10 l.686E+OO 8.029E-07 8.477E-07 16.33 785.83 ------
- 1. 09 8.674E-Ol Line Not Found ------
839.00 ------
0.59 8.122E-Ol Line Not Found ------
Nuclide Line Activity Report ( continued)
Page :
6 Sample ID : 30284 Acquisition date 30-MAY-2014 13:13:36 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error RN-222 510.00 22 0.07*
1.298E+OO
- 81. 07 0.18 l.802E+OO Line Not Found ------
186.11 27 3.28*
2.262E+OO
- 2. 897E--06 2.897E-06
- 41. 73 AC-228 89.96 ------
3.40 2.051E+OO Line Not Found ------
93.35 46 5.60 2.120E+OO 3.106E-06 3.118E-06 28.60 99.55 ------
- 1. 30 2.229E+OO Line Not Found ------
105.36 ------
2.00 2.301E+OO Line Not Found ------
108.99 ------
0.67 2.335E+OO Line Not Found ------
12 9. 03 ------
2.90 2.414E+OO Line Not Found ------
153.89 ------
0.84 2.377E+OO Line Not Found 209.39 4.10 2.168E+OO ------
Line Not Found ------
216.24 0.80 2.141E+OO Line Not Found ------
270.26 ------
3.80 1.941E+OO Line Not Found ------
328.07 ------
3.50
- 1. 756E+OO Line Not Found ------
338.42 25 12.40 1.726E+OO 9.431E-07 9.469E-07 27.75 340.94 0.52
- 1. 718E+OO Line Not Found ------
409.62 2.20 1.531E+OO Line Not Found ------
463.10 ------
- 4. 60 1.401E+OO Line Not Found ------
562.65 ------
- 1. 01 1.195E+OO Line Not Found ------
581.52 ------
3.00 1.160E+OO ------
Line Not Found ------
726.63 ------
0.87 9.382E-01 ------
Line Not Found ------
755.28
- 1. 32 9.027E-01 ------
Line Not Found ------
772. 28 ------
- 1. 09 8.827E-Ol ------
Line Not Found ------
782.12 0.59 8.716E-01 ------
Line Not Found ------
794.79 ------
4.60 8.576E-01 Line Not Found 830.59 ------
0.63 8.205E-01 ------
Line Not Found ------
835.60
- 1. 71 8.155E-01 ------
Line Not Found ------
840.44 ------
0.94 8.108E-01 ------
Line Not Found ------
904.29 ------
0.89 7.542E-01 ------
Line Not Found ------
911.16 21 29.00*
7.488E-01 7.682E-07 7, 712E-07 26.23 964. 64 5.80 7.091E-01 Line Not Found ------
968.97 17.40 7.061E-01 Line Not Found ------
1246.60 ------
0.57 5.825E-01 ------
Line Not Found ------
1459.19 ------
- 1. 06 5.560E-01 ------
Line Not Found ------
1496.00 ------
- 1. 05 5.563E-01 ------
Line Not Found ------
1501. 44 0.58 5.565E-01 ------
Line Not Found ------
1580.30 ------
0.71 5.624E-01 ------
Line Not Found ------
1588.23 ------
3.60 5.634E-01 ------
Line Not Found ------
1630.47 ------
- 1. 95
- 5. 696E-01 Line Not Found ------
1638.10 ------
0.54 5.709E-01 ------
Line Not Found ------
- 89. 96 ------
3.36 2.051E+OO Line Not Found ------
93.35 46 5.50 2.120E+OO 3.162E-06 3.162E-06 28.60 105.36 ------
- 1. 98 2.301E+OO Line Not Found ------
109.18 ------
- 1. 50 2.336E+OO Line Not Found ------
143.79 10.50 2.402E+OO Line Not Found ------
163.38 ------
4.70 2.347E+OO Line Not Found ------
185.74 27 53.00*
2.262E+OO
- 1. 7 93E-07
- 1. 793E-07 41.73 194.96 ------
0.59 2.226E+OO Line Not Found ------
202.13 ------
- 1. 00 2.197E+OO Line Not Found ------
Nuclide Line Activity Report (continued)
Sample ID : 30284 Acquisition date Page :
7 30-MAY-2014 13:13:36 Nuclide Type: natural Nuclide Flag: "*"
Energy 205.33 Keyline Area
%Abn 4.70
%Eff 2.184E+OO Uncorrected Decay Corr uCi/GR uCi/GR Line Not Found 1-Sigma
%Error
Minimum Detectable Activity Report Page :
8 Sample ID 30284 Acquisition date 30-MAY-2014 13:13:36 Bckgnd Energy MDA Nuclide Sum (keV)
(uCi/GR)
BE-7
- 5.
477.61 7.3754E-07 MN-54
- 1.
834.83 7.3495E-08 MN-56
- 2.
846.81 1.0017E-07 C0-57
- 25.
122.06 1.0125E-07 C0-58
- 4.
810.79 1.1466E-07 C0-60
- 2.
1173.24
- 1. 2286E-07 SB-124
- 5.
602.73 9.3833E-08 SB-125
- 4.
427.88 2.1966E-07 CS-134
- 1.
795.87 8.0324E-08 CS-137
- 7.
661.66 l.3414E-07