Health Physics Sample Recor_d_s ______________________ ~

Sample ID:

142491 Type: RLSSS Type Detail: SAND

==

Description:==

140605BD02 SOUTH LAY DOWN# 3

!Common Resp Org: P4000 - PROJECT MANAGEMEr

Contact:

COOPER, TERRY L Reference ID:

Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:

I Origin Mat. SizeNolume:

1918 GRAMS

==

Description:==

SOUTH LAY DOWN# 3

[Colle~~

Sample Tech:

DYNES, WILLIAM J Tritium Req:

No Instructions:

COUNT TO MDA Comments:

COUNT TO MDA RLSSS I Exempt:

No Chem Notification:

No Offsite Analysis:

No Container Surveyed:

No Container Evaluated:

Yes ILocationJ Status: APPROVED Cross Ref Sample ID:

Survey No:

Accounting Subcode:

Unknown Mat:

NO Date: 06/06/14 07:22 Docmnt/MO/Act #:

Proposed Ship Date: 00/00/00 00:00 Sample Date: 06/05/1413:20 Sample SizeNolume: 1918 GRAMS Evaluated:

No State Permit:

No Effluent Permit:

No Cleared For Release:

Yes Form 212 Ready:

~

Unit: NON-UNIT RE Stored By:,

Sample Loe:

Area: MS Elev: 100 Room:

Depth:

(in.)

Equip ID:

Date: 00/00/00 00:00 Other: COUNT TO MDA Material Loe:

06/19/2014 09:53 Rasterized: r Priority: N Hazardous Mat:

NO Count Time:

900 (secs.)

Page 1 of 3

H_e_a_lt_h_P_h~y~s_ic_s_S_a_m~p_le_R_e_c_o_rds ______________________ ~

Sample ID:

142491 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140605BD02 SOUTH LAY DOWN# 3

~nalysi~J Geometry MCAID Quant.

Units Method FP/AP C_ 1 L_marinelli_sand -

30383 1918GR

.000 Isotope Mode Activity Activity Uncert.

LLD/MDA

%Abund.

0 K-40 NT 0.0000138!:: 1.37E-6 r

74.332%

0 TL-208 NT 1.898E-7 6.91E-8 r

1.016%

0 PB-212 NT 5.796E-7 9.27E-8

  • r 3.102%

0 Bl-214 NT 4.617E-7 8.9E-8 2.471%

0 PB-214 NT 5.666E-7 1.719E-7 3.032%

0 RA-226 NT 2.824E-6 1.024E-6 r

15.113%

0 U-235 NT 1.748E-7 6.34E-8 r

0.935%

0 BE-7 AP 4.5886E-7 Iv 0.000%

0 MN-54 AP 1.4529E-7 jv 0.000%

0 MN-56 AP 9.4588E-8 jv 0.000%

0 C0-57 AP 7.4995E-8 jv 0.000%

0 C0-58 AP 1.0045E-7 jv 0.000%

0 C0-60 AP 1.1751E-7

~

0.000%

0 SB-124 AP 6.138E-8 IV 0.000%

0 SB-125 FP 2.1472E-7 w

0.000%

0 CS-134 FP 9.5631E-8 jv 0.000%

0 CS-137 FP 8.9946E-8 Iii" 0.000%

Analysis Review j Re-Analize:

No Lie Rad Mat Present:

No Hp Eng Rvw Reqd:

Yes Comments:

06/19/2014 09:53 Rad Mat Present:

Yes Atom. No.

40 208 212 214 214 226 235 7

54 56 57 58 60 124 125 134 137 Lab Analysis By LYLE, OWEN M Comments Reviewed: COOPER, TERRY L HP Notified Name:

Rasterized: r Date Mod ID Mod Date 06/06/14 14:03 Mod Id Mod Date Date: 06/11/14 06:26 Page 2 of 3

Health Physics Sample Records Sample ID:

142491 Type: RLSSS Type Detail: SAND Status: APPROVED

==

Description:==

140605BD02 SOUTH LAY DOWN# 3 r Review/Approve I H::c:.::_P-=E=ng Review Reviewed: COOPER, TERRY L Date: 06/11/14 06:38 Comments: U-235 is likely a mis-ID off the Ra-226 energy peak; the 338 keV peak is Ac-228 Disposition: OTHER Remarks:

Approved: COOPER, TERRY L Comments:

06/19/2014 09:53 Disposition Result: Sample contains only natural isotopes Final Apprnval Date: 06/11/14 06:38 Rasterized: r Page 3 of 3

SONGS HEALTH PHYSICS REPORT 6-JUN-2014 13:58

  • Title

>>>>> SAMPLE PARAMETERS<<<<<

140605BD02 SOUTH LAY DOWN# 3

  • ID
  • Start Time:
  • Stop Time:
  • Quantity 30383 6-JUN-2014 13:55:00.

6-JUN-2014 13:55:00.

l.91800E+03 GR Acquisition date: 6-JUN-2014 13:55:49. *

  • Geometry C lL marinelli sand 1 Operator: OWEN Counting System IHPS Sample Number:

Analysis Library LYLE U2GSP 142491 HP NATURAL

>>>>> C #41-TP11750A PARAMETERS<<<<<

  • Elapsed Live Time
  • Elapsed Real Time
  • Deadtime
  • Activity Mult Factor:
  • Half Life Ratio 0 00:03:00.42 0 00:03:00.46 0.0%

1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:

Sensitivity 5-JUN-2014 19:42:

-1.03481E-01 4.99812E-01

1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1

186.10 27 20

1. 43 372.54 368 9 36.3 1. 28E+OO U-235 RA-226 1

238.63 66 18 1.15 477.62 472 9 16.0 1. 99E+OO PB-212 1

241. 80 24 10

1. 33 483.97 482 5 28.5 1. 84E+OO PB-214 1

295.11 24 8

1. 92 590.61 585 11 30.3 3.34E-01 PB-214 1

338.28 29 11 2.13 676.97 671 11 28.7 4.26E-01 1

352.00 38 6

1. 23 704.43 700 8 19.5 6.69E-01 PB-214 1

583.28 15 6

2.18 1167. 08 1163 8 36.4 7. llE-01 TL-208 1

60 9. 4 9 28 0

1. 94 1219.50 1215 8 19.3 l.50E+OO BI-214 1

1460.84 106 0

2.12 2922.19 2914 14 9.8 9.19E-01 K-40

Summary of Nuclide Activity Sample ID : 30383 Total number of lines in spectrum Number of unidentified lines Acquisition date Page :

2 6-JUN-2014 13:55:49 Number of lines tentatively identified by NID 9

0 9

100.00%

Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error

%Error Flags K-40 1.28E+09Y

1. 00 l.389E-05 1.389E-05 0.137E-05 9.85 A

TL-208 3.05M

1. 66 1.141E-07 1.898E-07 0.691E-07 36.39 A

PB-212 10.64H

1. 00 5.781E-07 5.796E-07 0.927E-07 15.99 A

BI-214 19.90M

1. 08 4.259E-07 4.617E-07 0.890E-07 19.27 A

PB-214

26. SOM
1. 06 5.336E-07 5.666E-07
1. 719E-07 30.33 A

RA-226 1600.00Y

1. 00 2.824E-06 2.824E-06 l.024E-06
36. 26 A

U-235 7.04E+08Y

1. 00 1.748E-07 1.748E-07 0.634E-07 36.26 A

Total Activity 1.854E-05 1.869E-05 Grand Total Activity :

l.854E-05 1.869E-05 Flags: "K" Keyline not found "M"

Manually accepted "E"

Manually edited "A"

Nuclide specific abn. limit

Unidentified Energy Lines Sample ID : 30383 Page :

3 Acquisition date : 6-JUN-2014 13:55:49 It 1

Energy 338.28 Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err

%Eff Flags 29 11 2.13 676.97 671 11 l.59E-Ol 28.7 1.73E+OO T

Flags: "T" = Tentatively associated

Interference Report Sample ID : 30383 No interference correction performed Acquisition date Page :

4 6-JUN-2014 13:55:49

Nuclide Line Activity Report Page :

5 Sample ID : 30383 Acquisition date 6-JON-2014 13:55:49 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area

%Abn

%Eff uCi/GR uCi/GR

%Error K-40 1460.83 106 10.67*

5.560E-01 1.389E-05 l.389E-05 9.85 TL-208

72. 80 2.14
1. 486E+OO Line Not Found ------

74.97 3.60 l.577E+OO Line Not Found ------

84.79 ------

1. 27 1.917E+OO Line Not Found ------

252.45 ------

0.80 2.004E+OO Line Not Found ------

277.28 6.80 1.917E+OO Line Not Found ------

510.61 ------

21. 60 1.298E+OO Line Not Found ------

583.02 15 86.00*

1.157E+OO l.141E-07 1.898E-07 36.39 763.06 ------

1. 64 8.934E-01 ------

Line Not Found ------

860.30 12.00 7.922E-01 ------

Line Not Found ------

PB-212 74.81 10.50 1.570E+OO Line Not Found ------

77.11 ------

17.70 l.661E+OO Line Not Found ------

87.19 ------

6.27 1.983E+OO Line Not Found ------

90.13 ------

1. 86 2.055E+OO Line Not Found ------

115. 12 0.59 2.376E+OO Line Not Found ------

238.58 66 43.60*

2.055E+OO 5.781E-07 5.796E-07 15.99 300.03 ------

3.34 1.843E+OO Line Not Found ------

BI-214 76.86 ------

0.58 1.651E+OO Line Not Found ------

79.29 ------

0.97

1. 741E+OO Line Not Found ------

609.31 28 46.10*

1.112E+OO 4.259E-07 4.617E-07 19.27 665.44

1. 56
1. 023E+OO Line Not Found ------

768.35 ------

4.88 8.873E-01 ------

Line Not Found ------

806.16 ------

1. 23 8.454E-01 ------

Line Not Found ------

934.04 3.16 7.310E-01 ------

Line Not Found ------

1120.27 ------

15.00 6.242E-01 ------

Line Not Found ------

1155.18 ------

1. 69 6.105E-01 ------

Line Not Found ------

1238.11 ------

5.92 5.846E-01 ------

Line Not Found ------

1280.95 ------

1. 47 5.747E-01 ------

Line Not Found ------

1377. 66 4.02 5.602E-01 ------

Line Not Found ------

1385.30 ------

0.78 5.595E-01 ------

Line Not Found ------

1401.48 ------

1. 39 5.583E-01 ------

Line Not Found ------

1407.97 2.48 5.578E-Ol ------

Line Not Found ------

1509.22 ------

2.19 5.568E-01 Line Not Found ------

1583.22 ------

0.72 5.628E-01 Line Not Found 1661.26 ------

1.15 5.753E-01 Line Not Found


M-1729.58 ------

3.05 5.918E-01 Line Not Found ------

1764.49 ------

15.90 6.023E-01 Line Not Found ------

1847.41 ------

2.12 6.331E-01 ------

Line Not Found ------

PB-214 53.17 ------

1.10 5.203E-01 Line Not Found ------

74.81 ------

6.52 l.570E+OO Line Not Found ------

77.11 ------

11. 00 l.661E+OO Line Not Found ------

87.19 ------

3.88 l.983E+OO Line Not Found ------

90.13 ------

1.15 2.055E+OO Line Not Found ------

241. 92 24 7.46 2.043E+OO l.248E-06 1.325E-06 28.46 258.94 0.55 l.981E+OO Line Not Found ------

295.09 24 19.20*

l.858E+OO 5.336E-07 5.666E-07 30.33 351.87 38 37.10 1.686E+OO 4.758E-07 5.052E-07 19.47 785.83

1. 09 8.674E-01 ------

Line Not Found ------

839.00 0.59 8.122E-01 ------

Line Not Found ------

Nuclide Line Activity Report (continued)

Page :

6 Sample ID : 30383 Acquisition date 6-JUN-2014 13:55:49 Nuclide Type: natural Nuclide RA-226 U-235 Flag: "*"

Energy

81. 07 186.11
89. 96 93.35 105.36 109.18 143.79 163.38 185.74 194. 96 202.13 205.33 Keyline Area 27 27

%Abn

%Eff 0.18 1.802E+OO 3.28*

2.261E+OO 3.36 2.051E+OO 5.50 2.124E+OO

1. 98 2.301E+OO
1. 50 2.336E+OO 10.50 2.402E+OO 4.70 2.347E+OO 53.00*

2.261E+OO 0.59 2.226E+OO

1. 00 2.197E+OO 4.70 2.184E+OO Uncorrected Decay Corr 1-Sigma uCi/GR uCi/GR

%Error Line Not Found ------

2.824E-06 2.824E-06 36.26 Line Not Found ------

Line Not Found ------

Line Not Found ------

Line Not Found ------

Line Not Found ------

Line Not Found ------

1.748E-07 l.748E-07 36.26 Line Not Found ------

Line Not Found ------

Line Not Found ------

Minimum Detectable Activity Report Page :

7 Sample ID 30383 Acquisition date 6-JUN-2014 13:55:49 Bckgnd Energy MDA Nuclide Sum (keV)

(uCi/GR)

BE-7

1.

477.61 4.5886E-07 MN-54

7.

834.83 1.4529E-07 MN-56

2.

846.81 9.4588E-08 C0-57

13.

122.06 7.4995E-08 C0-58

3.

810.79 l.0045E-07 C0-60

2.

1332.50 l.1751E-07 SB-124

2.

602.73 6.1380E-08 SB-125

4.

427.88 2.1472E-07 CS-134

5.

604. 71 9.5631E-08 CS-137

3.

661.66 8.9946E-08