ML20034E024
Text
Sample ID:
142494 Type: RLSSS Type Detail: SAND
==
Description:==
140605BD05 SOUTH LAY DOWN# 10 Common Resp Org: P4000 - PROJECT MANAGEMEt
Contact:
COOPER, TERRY L Reference ID:
Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:
I OrLginJ Health Physics Sample Records Status: APPROVED Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Unknown Mat:
NO Date: 06/06/14 07:42 Mat. SizeNolume:
1965 GRAMS Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00
==
Description:==
SOUTH LAY DOWN# 10 Collection Sample Tech:
DYNES, WILLIAM J Tritium Req:
No Instructions:
COUNT TO MDA Comments:
COUNT TO MDA lBJc.§55 Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
No I Locj_!L~!!J Unit: NON-UNIT RE Stored By:,
Sample Loe:
Area: MS Other: COUNT TO MDA Material Loe:
06/19/2014 10:04 Sample Date: 06/05/14 09:30 Sample SizeNolume: 1965 GRAMS Evaluated:
No State Permit:
No Effluent Permit:
No Cleared For Release:
Yes Form 212 Ready:
Elev: 100 Room:
Depth:
(in.)
Equip ID:
Date: 00/00/00 00:00 Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of 3
Health Physics Sample Record_s ______________________ ~
Sample ID:
142494 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140605BD05 SOUTH LAY DOWN# 10 IAnalysisl Geometry A_ 1 L_marinelli_sand_
MCA ID Quant.
Units 30391 1965GR Method
_Isotope _Mode_ Activity Activity Uncert.
LLD/MDA 0
K-40 NT 0
TL-208 NT 0
PB-212 NT 0
81-214 NT 0
PB-214 NT 0
RA-226 NT 0
U-235 NT 0
BE-7 AP 0
MN-56 AP 0
C0-57 AP 0
C0-58 AP 0
C0-60 AP 0
SB-124 AP 0
SB-125 FP 0
CS-134 FP 0
CS-137 FP I Analysis Review J 0.00001202 1.29E-6 2.945E-7 6.29E-8 4.91E-7 1.023E-7 4.116E-7 1.004E-7 5.792E-7 1.024E-7 2.513E-6 5.71E-7 1.555E-7 3.53E-8 6.4191E-7 1.3763E-7 7.2531E-8 6.9045E-8 8.6299E-8 1.1988E-7 9.9677E-8 1.9237E-7 9.4504E-8 1.0511E-7 r r r r r
iv W-W' iv iv
~
~
~
Iv
~
FP/AP
.000
%Abund.
73.021%
1.788%
2.980%
2.498%
3.516%
15.254%
0.944%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
Re-Analize:
No Lie Rad Mat Present:
No Hp Eng Rvw Reqd:
Yes Rad Mat Present:
Yes Comments:
06/19/2014 10:04 Atom. No.
40 208 212 214 214 226 235 7
54 56 57 58 60 124 125 134 137 Lab Analysis By NEESE, DAVID J Comments Reviewed: COOPER, TERRY L HP Notified Name:
Rasterized:
Date Mod ID Mod Date 06/06/14 20:58 Mod Id Mod Date Date: 06/11/14 06:44 Page 2 of 3
Health Physics Sample Records Sample ID:
142494 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140605BD05 SOUTH LAY DOWN# 10 r Review/Approve I HP Review Reviewed: COOPER, TERRY L Date: 06/11/14 06:47 Comments: U-235 is a likely mis-ID off the Ra-226 energy peak; the 338 keV peak is Ac-228 Disposition: OTHER Remarks:
~~~~~~*-------------------*---
Approved: COOPER, TERRY L Comments:
06/19/2014 10:04 Disposition Result: Sample contains only natural isotopes Final Ap_p_roval Date: 06/11/14 06:48 Rasterized:
Page 3 of 3
SONGS HEALTH PHYSICS REPORT 6-JUN-2014 20:54
- Title
>>>>> SAMPLE PARAMETERS<<<<<
140605BD05 SOUTH LAY DOWN# 10
- ID 30391 Acquisition date: 6-JUN-2014 20:51:44. *
- Start Time:
- Stop Time:
- Quantity
- Geometry 6-JUN-2014 20:51:00.
6-JUN-2014 20:51:00.
Counting System 1.96500E+03 GR IHPS Sample Number:
A lL marinelli_sand_l Analysis Library Operator: DAVID NEEBE U2GSP 142494 HP NATURAL
>>>>> A #41-TP11679B PARAMETERS<<<<<
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.45 0 00:03:00.50 0.0%
1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 6-JUN-2014 20:05:
2.54391E-01 4.99481E-01 1.00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1
77.32 33 38
- 1. 35 154.30 151 8 37.3 2.29E+OO BI-214 PB-212 PB-214 1
185.55 25 4
238.44 58 28
- 1. 08 476.86 473 9 20.8 2.38E+OO PB-212 1
338.15 17 0
- 1. 46 676.49 671 10 27.7 7.84E-01 1
352.03 44 4
1.17 704.27 699 9 17.7 6.52E-01 PB-214 1
583.53 23 0
- 1. 85 1167. 75 1163 10 21. 4 4.82E-01 TL-208 1
609.53 25 2
- 1. 28 1219.80 1215 9 24.4 1. 87E+OO BI-214 1
1461.00 89 0
- 1. 99 2924.37 2919 11 10.7 8.78E-01 K-40
Summary of Nuclide Activity Sample ID : 30391 Total number of lines in spectrum Number of unidentified lines Page :
2 Acquisition date 6-JUN-2014 20:51:44 Number of lines tentatively identified by NID 8
0 8
100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error Flags K-40 1.28E+09Y
- 1. 00 1.203E-05 1.203E-05 0.129E-05 10.72 A
TL-208 3.05M
- 1. 63 l.804E-07 2.945E-07 0.629E-07
- 21. 35 A
PB-212 10.64H
- 1. 00 4.898E-07
- 4. 910E-07 l.023E-07 20.83 A
BI-214 19.90M
- 1. 08 3.808E-07 4.116E-07 l.004E-07 24.39 A
PB-214
- 26. SOM
- 1. 06 5.466E-07 5.792E-07 1.024E-07 17.68 KA RA-226 1600.00Y
- 1. 00 2.513E-06 2.513E-06
- 0. 571E-06 22.73 A
U-235 7.04E+08Y
- 1. 00 1.555E-07 1.555E-07 0.353E-07 22.73 A
Total Activity 1.630E-05
- 1. 64 7E-05 Grand Total Activity :
1.630E-05 1.647E-05 Flags: "K" Keyline not found "M"
Manually accepted "E"
Manually edited "A"
Nuclide specific abn. limit
Unidentified Energy Lines Sample ID : 30391 Page :
3 Acquisition date : 6-JUN-2014 20:51:44 It 1
Energy 330.15 Area Bkgnd FWHM Channel Left Pw Cts/Sec %Err
%Eff Flags 17 0
1.46 676.49 671 10 9.39E-02 27.7 1.70E+OO T
Flags: "T" = Tentatively associated
Interference Report Sample ID : 30391 No interference correction performed Acquisition date Page :
4 6-JUN-2014 20:51:44
Nuclide Line Activity Report Page :
5 Sample ID : 30391 Acquisition date 6-JUN-2014 20:51:44 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 89 10.67*
5.314E-01
- 1. 203E-05
- 1. 203E-05
- 10. 72 TL-208
- 72. 80 2.14 l.594E+OO ------
Line Not Found ------
74.97 3.60 1.692E+OO Line Not Found ------
84.79 ------
- 1. 27 2.058E+OO Line Not Found ------
252.45 ------
0.80 2.021E+OO Line Not Found ------
277.28 6.80 l.920E+OO Line Not Found ------
510.61 ------
- 21. 60 1.265E+OO ------
Line Not Found ------
583.02 23 86.00*
1.127E+OO l.804E-07 2.945E-07
- 21. 35 763.06 ------
- 1. 64 8.744E-01 ------
Line Not Found ------
860.30 12.00 7.770E-Ol ------
Line Not Found ------
PB-212 74.81 ------
10.50 l.685E+OO Line Not Found ------
77.11 33 17.70
- 1. 7 91E+OO 8.046E-07 8.065E-07 37.32 87.19 ------
6.27 2.129E+OO ------
Line Not Found ------
90.13
- 1. 86 2.206E+OO Line Not Found ------
115. 12 0.59 2.535E+OO Line Not Found ------
238.58 58 43.60*
2.083E+OO 4.898E-07 4.910E-07 20.83 300.03 ------
3.34 1.834E+OO ------
Line Not Found ------
BI-214
- 76. 86 33 0.58 1.791E+OO 2.455E-05 2.654E-05 37.32 79.29 ------
0.97 l.869E+OO Line Not Found ------
609.31 25 46.10*
l.084E+OO 3.808E-07 4.116E-07 24.39 665.44 ------
- 1. 56 9.985E-01 ------
Line Not Found ------
768.35 ------
4.88 8.685E-01 ------
Line Not Found ------
806.16 ------
- 1. 23 8.283E-01 ------
Line Not Found ------
934.04 3.16 7.177E-01 ------
Line Not Found ------
1120.27 15.00 6.114E-01 Line Not Found ------
1155.18 ------
- 1. 69 5.973E-01 ------
Line Not Found ------
1238.11 ------
5.92 5.697E-01 ------
Line Not Found ------
1280.95 ------
- 1. 4 7 5.585E-01 ------
Line Not Found ------
1377. 66 4.02 5.401E-01 ------
Line Not Found ------
1385.30 0.78
- 5. 391E-01 ------
Line Not Found ------
1401.48
- 1. 39 5.370E-01 ------
Line Not Found ------
1407.97 2.48 5.362E-01 ------
Line Not Found ------
1509.22 2.19 5.292E-01 ------
Line Not Found ------
1583.22
- 0. 72 5.296E-01 Line Not Found ------
1661. 26 1.15 5.351E-01 ------
Line Not Found ------
1729.58 3.05 5.442E-01 ------
Line Not Found ------
1764.49 ------
15.90 5.503E-01 ------
Line Not Found ------
1847.41 ------
2.12 5.694E-01 ------
Line Not Found ------
PB-214 53.17 ------
1.10 5.543E-01 ------
Line Not Found ------
74.81 ------
6.52 l.685E+OO Line Not Found ------
77.11 33
- 11. 00 l.791E+OO 1.295E-06 l.372E-06 37.32 87.19 ------
3.88 2.129E+OO Line Not Found ------
90.13 1.15 2.206E+OO Line Not Found ------
241. 92 7.46 2.067E+OO Line Not Found ------
258.94 0.55 l.994E+OO Line Not Found ------
295.09 19.20*
l.852E+OO Line Not Found ------
351. 87 44 37.10 l.662E+OO 5.466E-07 5.792E-07 17.68 785.83
- 1. 09 8.495E-01 Line Not Found ------
839.00 0.59 7.964E-01 ------
Line Not Found ------
Nuclide Line Activity Report (continued)
Page :
6 Sample ID : 30391 Acquisition date 6-JUN-2014 20:51:44 Nuclide Type: natural Nuclide RA-226 U-235 Flag: "*"
Energy
- 81. 07 186.11
- 89. 96 93.35 105.36 109.18 143.79 163.38 185.74 194.96 202.13 205.33 Keyline Area 25 25
%Abn
%Eff 0.18 l.934E+OO 3.28*
2.342E+OO 3.36 2.201E+OO 5.50 2.279E+OO
- 1. 98 2.463E+OO
- 1. 50 2.498E+OO 10.50 2.533E+OO 4.70 2.453E+OO 53.00*
2.342E+OO 0.59 2.294E+OO
- 1. 00 2.257E+OO 4.70 2.241E+OO Uncorrected Decay Corr 1-Sigma uCi/GR uCi/GR
%Error Line Not Found ------
- 2. 513E-06 2.513E-06 22.73 Line Not Found ------
Line Not Found ------
Line Not Found ------
Line Not Found ------
Line Not Found Line Not Found ------
1.555E-07 1.555E-07 22.73 Line Not Found ------
Line Not Found ------
Line Not Found ------
Minimum Detectable Activity Report Sample ID 30391 Nuclide BE-7 MN-54 MN-56 C0-57 C0-58 C0-60 SB-124 SB-125 CS-134 CS-137 Bckgnd Sum
- 4.
- 6.
- 1.
- 14.
- 2.
- 2.
- 6.
- 3.
- 5.
- 4.
Energy (keV) 477.61 834.83 846.81 122.06 810.79 1173.24 602.73 427.88 604. 71 661. 66 Acquisition date MDA (uCi/GR) 6.4191E-07 1.3763E-07 7.2531E-08 6.9045E-08 8.6299E-08 1.1988E-07
- 9. 9677E-08 l.9237E-07 9.4504E-08
- 1. OSllE-07 Page :
7 6-JUN-2014 20:51:44