ML20034D987
Text
Health Physics Sample Records Sample ID:
142464 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140529BD 01 STARYARD SURVEY PT 36 lcommon1 Resp Org: P4000 - PROJECT MANAGEMEr
Contact:
COOPER, TERRY L Reference ID:
Comments: COUNT TO MDA Reviewed: DYNES, WILLIAM J Comments:
Origin Cross Ref Sample ID:
Survey No:
Accounting Subcode:
Date: 06/04/14 07:57 Unknown Mat:
NO Mat. SizeNolume:
2286 GRAMS Docmnt/MO/Act #:
Proposed Ship Date: 00/00/00 00:00
==
Description:==
STARYARD SURVEY PT 21 Collection Sample Tech:
DYNES, WILLIAM J Tritium Req:
No Instructions:
COUNT TO MDA Comments:
COUNT TO MDA RLSSS Exempt:
No Chem Notification:
No Offsite Analysis:
No Container Surveyed:
No Container Evaluated:
Yes lLocation Unit: NON-UNIT RE Stored By:,
Sample Loe:
Other:
Material Loe:
06/18/2014 14:02 Area: MS Evaluated:
State Permit:
Effluent Permit:
Cleared For Release:
Form 212 Ready:
Elev: 100 Room:
Date: 00/00/00 00:00 Sample Date: 05/30/1411:55 Sample SizeNolume: 2286 GRAMS No No No Yes Ji1' Depth:
(in.)
Equip ID:
Rasterized: r Priority: N Hazardous Mat:
NO Count Time:
900 (secs.)
Page 1 of 3
Sample ID:
142464 Type: RLSSS Type Detail: SAND Health Physics Sample Records Status: APPROVED
==
Description:==
140529BD 01 STARYARD SURVEY PT 36 Analysis
~eometry MCAID Quant.
Units Method FP/AP C_1L_marinelli_sand -
30359 2286GR
.000 Isotope Mode _Activity Activity Uncert.
LLD/MDA
%Abund.
0 K-40 NT 8.774E-6 0
TL-208 NT 2.493E-7 0
PB-212 NT 3.95E-7 0
Bl-214 NT 4.87E-7 0
PB-214 NT 6.0E-7 0
RA-226 NT 2.375E-6 0
AC-228 NT 5.342E-7 0
U-235 NT 1.47E-7 0
BE-7 AP 1.2455E-7 0
MN-56 AP 1.0616E-7 0
C0-57 AP 7.1802E-8 0
C0-58 AP 6.9665E-8 0
C0-60 AP 1.0077E-7 0
SB-124 AP 6.4633E-8 0
SB-125 FP 1.8496E-7 0
CS-134 FP 5.9089E-8 0
[Analysis-Review I Re-Analize:
No Hp Eng Rvw Reqd:
Yes Comments:
06/18/2014 14:02 9.82E-7 r
64.698%
7.8E-8 r
1.838%
7.64E-8 r
2.913%
8.17E-8 r
3.591%
1.79E-7 r
4.424%
1.006E-6 r
17.513%
1.91 E-7 r
3.939%
6.23E-8 r
1.084%
V 0.000%
W' 0.000%
V 0.000%
V 0.000%
lv 0.000%
iv'"
0.000%
lv 0.000%
iV 0.000%
lv 0.000%
iv 0.000%
Lie Rad Mat Present:
No Rad Mat Present:
Yes Atom. No.
40 208 212 214 214 226 228 235 7
54 56 57 58 60 124 125 134 137 Lab Analysis By PARK, MICHAEL C Comments Reviewed: COOPER, TERRY L HP Notified Name:
Rasterized: r Date Mod ID Mod Date 06/05/1415:13 Mod Id Mod Date Date: 06/10/1413:33 Page 2 of 3
Health Physics Sample Records Sample ID:
142464 Type: RLSSS Type Detail: SAND Status: APPROVED
==
Description:==
140529BD 01 STARYARD SURVEY PT 36 I Rev~iew/Approvel HP Eng Review Reviewed: COOPER, TERRY L Date: 06/10/14 13:33 Comments: U-235 is likely mis-lD'd off the Ra-226 energy peak Disposition: OTHER Remarks:
Approved: COOPER, TERRY L Comments:
06/18/201414:02 Disposition Result: Sample contains only natural isotopes Final Approval Date: 06/10/1413:33 Rasterized: r Page 3 of 3
SONGS HEALTH PHYSICS REPORT 5-JUN-2014 15:03
- Title
>>>>> SAMPLE PARAMETERS<<<<<
140529BD 01 STARYARD SURVEY PT 36
- ID 30359 Acquisition date: 5-JUN-2014 15:00:18. *
- Start Time:
- Stop Time:
- Quantity
- Geometry 5-JUN-2014 15:00:00.
5-JUN-2014 15:00:00.
Counting System 2.28600E+03 GR IHPS Sample Number:
C lL marinelli_sand_l Analysis Library Operator: MICHAEL PARK U2GSP 142464 HP NATURAL
>>>>> C #41-TP11750A PARAMETERS<<<<<
- Elapsed Live Time
- Elapsed Real Time
- Deadtime
- Activity Mult Factor:
- Half Life Ratio 0 00:03:00.41 0 00:03:00.45 0.0%
1.00000E+OO 8.00000 Calibration Energy Offset Energy Slope Energy Tolerance:
Sensitivity 5-JUN-2014 08:14:
-1.39807E-01 4.99820E-01
- 1. 00000 5.00000 Post-NID Peak Search Report It Energy Area Bkgnd FWHM Channel Left Pw %Err Fit Nuclides 1
76.94 67 48 2.88 154.21 151 10 23.0 4.77E+OO BI-214 PB-212 PB-214 1
186.12 27 27 2.56 372. 65 367 11 42.4 1.42E+OO U-235 RA-226 1
238.66 54 17 1.12 477.75 474 7 19.3 3.44E+OO PB-212 1
295.31 31 15 1.17 591. 07 585 10 29.8 1.26E+OO PB-214 1
338.21 20 12 2.37 676.90 672 10 37.5 1. 71E+OO AC-228 1
351.88 43 9
- 1. 30 704.25 700 11 20.1 5.15E-01 PB-214 1
583.22 26 9
- 1. 50 1167.02 1161 12 31. 3 9.04E-01 TL-208 1
609.59 36 0
2.11 1219.77 1215 10 16.8 4.67E-01 BI-214 1
911. 27 18 7
2.18 1823.16 1818 10 35.7 8.75E-01 AC-228 1
1460.85 79 0
2.02 2922.22 2917 11 11. 2 2.28E-01 K-40
Page :
2 Summary of Nuclide Activity Sample ID : 30359 Acquisition date 5-JUN-2014 15:00:18 Total number of lines in spectrum 10 Number of unidentified lines 0
Number of lines tentatively identified by NID 10 100.00%
Nuclide Type : natural Uncorrected Decay Corr Decay Corr 1-Sigma Nuclide Hlife Decay uCi/GR uCi/GR 1-Sigma Error
%Error Flags K-40 l.28E+09Y
- 1. 00 8.774E-06 8.774E-06 0.982E-06 11.19 A
TL-208 3.05M
- 1. 48 l.684E-07 2.493E-07 0.780E-07
- 31. 28 A
PB-212 10.64H
- 1. 00 3.942E-07 3.950E-07 0.764E-07 19.34 A
BI-214 19.90M
- 1. 06 4.575E-07 4.870E-07 0.817E-07 16.78 A
PB-214 26.80M
- 1. 05 5.727E-07 6.000E-07 l.790E-07 29.84 A
RA-226 1600.00Y
- 1. 00 2.375E-06 2.375E-06 1.006E-06 42.36 A
AC-228 6.13H
- 1. 00 5.324E-07 5.342E-07 1.910E-07 35.75 A
U-235 7.04E+08Y
- 1. 00 1.470E-07 1.470E-07 0.623E-07 42.36 A
Total Activity 1.342E-05 1.356E-05 Grand Total Activity :
1.342E-05
- 1. 356E-05 Flags: "K" Keyline not found "M"
Manually accepted "E"
Manually edited "A"
Nuclide specific abn. limit
Unidentified Energy Lines Sample ID : 30359 None Flags: "T" Tentatively associated Page :
3 Acquisition date 5-JUN-2014 15:00:18
Interference Report Sample ID : 30359 No interference correction performed Acquisition date Page :
4 5-JUN-2014 15:00:18
Nuclide Line Activity Report Page :
5 Sample ID : 30359 Acquisition date 5-JUN-2014 15:00:18 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error K-40 1460.83 79 10.67*
5.560E-01 8.774E-06 8.774E-06 11.19 TL-208
- 72. 80 2.14 1.486E+OO Line Not Found ------
7 4. 97 3.60 1.577E+OO Line Not Found ------
84.79 ------
- 1. 27 1.917E+OO ------
Line Not Found ------
252.45 ------
0.80 2.004E+OO Line Not Found ------
277.28 ------
6.80 1.917E+OO Line Not Found ------
510.61 ------
- 21. 60 1.298E+OO Line Not Found ------
583.02 26 86.00*
1.157E+OO 1.684E-07 2.493E-07
- 31. 28 763.06 ------
- 1. 64 8.934E-01 Line Not Found ------
860.30 ------
12.00 7.922E-01 Line Not Found ------
PB-212 74.81 ------
10.50 l.570E+OO Line Not Found ------
77.11 67 17.70 1.654E+OO 1.499E-06 l.502E-06 23.02 87.19 ------
6.27
- 1. 983E+OO Line Not Found ------
90.13 ------
- 1. 86 2.055E+OO ------
Line Not Found ------
115. 12 0.59 2.376E+OO Line Not Found ------
238.58 54 43.60*
2.055E+OO 3.942E-07 3.950E-07 19.34 300.03 ------
3.34 l.843E+OO Line Not Found ------
BI-214 76.86 67 0.58 1.654E+OO 4.576E-05 4.872E-05 23.02 79.29 ------
0.97
- 1. 741E+OO Line Not Found ------
609.31 36 46.10*
- 1. lllE+OO 4.575E-07 4.870E-07 16.78 665.44
- 1. 56 1.023E+OO Line Not Found ------
768.35 ------
4.88 8.873E-01 Line Not Found ------
806.16 ------
- 1. 23 8.454E-01 ------
Line Not Found ------
934.04 3.16 7.310E-01 Line Not Found ------
1120. 27 15.00 6.242E-01 Line Not Found ------
1155. 18 ------
- 1. 69 6.105E-01 Line Not Found ------
1238.11 ------
5.92 5.846E-01 ------
Line Not Found ------
1280.95
- 1. 47 5.747E-01 ------
Line Not Found ------
1377.66 4.02 5.602E-Ol ------
Line Not Found ------
1385.30 ------
0.78 5.595E-01 ------
Line Not Found ------
1401.48 ------
- 1. 39 5.583E-01 ------
Line Not Found ------
1407.97 ------
2.48 5.578E-01 Line Not Found ------
1509.22 ------
2.19 5.568E-01 ------
Line Not Found ------
1583.22 ------
0.72 5.628E-Ol Line Not Found ------
1661.26 ------
1.15 5.753E-01 Line Not Found ------
1729.58 ------
3.05 5.918E-01 ------
Line Not Found ------
1764.49 ------
15.90 6.023E-01 Line Not Found ------
1847.41 ------
2.12 6.331E-01 Line Not Found ------
PB-214 53.17 1.10 5.203E-01 ------
Line Not Found ------
74.81 ------
6.52
- 1. 570E+OO ------
Line Not Found 77.11 67
- 11. 00 1.654E+OO 2.413E-06 2.528E-06 23.02 87.19 ------
3.88 1.983E+OO ------
Line Not Found ------
90.13 1.15 2.055E+OO Line Not Found ------
241. 92 7.46 2.043E+OO Line Not Found ------
258.94 0.55 1.981E+OO Line Not Found ------
295.09 31 19.20*
l.858E+OO 5.727E-07
- 6. OOOE-*07 29.84 351. 87 43 37.10 l.686E+OO 4.554E-07 4.771E-07 20.15 785.83 ------
- 1. 09 8.674E-01 ------
Line Not Found ------
839.00 0.59 8.122E-01 ------
Line Not Found
Nuclide Line Activity Report (continued)
Page :
6 Sample ID : 30359 Acquisition date 5-JUN-2014 15:00:18 Nuclide Type: natural Uncorrected Decay Corr 1-Sigma Nuclide Energy Area
%Abn
%Eff uCi/GR uCi/GR
%Error RA-226
- 81. 07 0.18 1.802E+OO Line Not Found ------
186.11 27 3.28*
2.261E+OO 2.375E-06 2.375E-06 42.36 AC-228
- 89. 96 3.40 2.051E+OO ------
Line Not Found ------
93.35 ------
5.60 2.124E+OO Line Not Found ------
99.55 ------
- 1. 30 2.229E+OO Line Not Found ------
105.36 ------
2.00 2.301E+OO Line Not Found ------
108.99 ------
0.67 2.335E+OO Line Not Found ------
12 9. 03 2.90 2.414E+OO Line Not Found ------
153.89 ------
0.84 2.377E+OO Line Not Found ------
209.39 ------
4.10 2.168E+OO Line Not Found ------
216.24 0.80 2.141E+OO Line Not Found ------
270.26 ------
3.80 1.941E+OO Line Not Found ------
328.07 3.50 1.756E+OO Line Not Found ------
338.42 20 12.40
- 1. 72 6E+OO 6.124E-07 6.145E-07 37.51 340.94 0.52
- 1. 718E+OO Line Not Found ------
409.62 2.20 1.531E+OO Line Not Found ------
463.10 4.60 1.401E+OO Line Not Found ------
562.65 ------
- 1. 01 1.195E+OO ------
Line Not Found ------
581. 52 3.00 l.160E+OO Line Not Found ------
726. 63 0.87 9.382E-Ol ------
Line Not Found ------
755.28
- 1. 32 9.027E-01 ------
Line Not Found ------
772. 28
- 1. 09 8.827E-01 ------
Line Not Found ------
782.12 0.59 8.716E-01 ------
Line Not Found ------
794.79 ------
4.60 8.576E-01 ------
Line Not Found ------
830.59 ------
0.63 8.205E-01 ------
Line Not Found ------
835.60
- 1. 71 8.155E-01 ------
Line Not Found ------
840.44 0.94 8.108E-01 ------
Line Not Found ------
904.29 ------
0.89 7.542E-01 ------
Line Not Found ------
911.16 18 29.00*
7.486E-01 5.324E-07 5.342E-07 35.75 964. 64 5.80 7.091E-01 ------
Line Not Found ------
968.97 17.40 7.061E-01 ------
Line Not Found ------
1246.60 ------
0.57 5.825E-01 ------
Line Not Found ------
1459.19 ------
- 1. 06 5.560E-01 Line Not Found ------
1496.00 ------
- 1. 05 5.563E-01 ------
Line Not Found ------
1501.44 0.58 5.565E-01 Line Not Found ------
1580.30
- 0. 71 5.624E-01 Line Not Found ------
1588.23 ------
3.60 5.634E-01 Line Not Found ------
1630.47
- 1. 95
- 5. 696E-01 Line Not Found ------
1638.10 ------
0.54 5.709E-01 Line Not Found ------
U-235 89.96 ------
3.36 2.051E+OO Line Not Found 93.35 ------
5.50 2.124E+OO Line Not Found ------
105.36 ------
- 1. 98 2.301E+OO Line Not Found ------
109.18
- 1. 50 2.336E+OO Line Not Found ------
143.79 ------
10.50 2.402E+OO Line Not Found ------
163.38 ------
4.70 2.347E+OO Line Not Found ------
185.74 27 53.00*
2.261E+OO l.470E-07 1.470E-07 42.36 194.96 ------
0.59 2.226E+OO Line Not Found ------
202.13 ------
- 1. 00 2.197E+OO Line Not Found ------
205.33 ------
4.70 2.184E+OO Line Not Found ------
Nuclide Line Activity Report (continued)
Page :
7 Sample ID : 30359 Acquisition date 5-JUN-2014 15:00:18 Flag: "*"
Keyline
Minimum Detectable Activity Report Page :
8 Sample ID 30359 Acquisition date 5-JUN-2014 15:00:18 Bckgnd Energy MDA Nuclide Sum (keV)
(uCi/GR)
BE-7
- 0.
477.61 1.2455E-07 MN-54
- 2.
834.83 7.8785E-08 MN-56
- o.
1810.80 l.0616E-07 C0-57
- 18.
122.06 7.1802E-08 C0-58
- 2.
810.79
- 6. 9665E-08 C0-60
- 2.
1173.24 1.0077E-07 SB-124
- 0.
1690.98 6.4633E-08 SB-125
- 4.
427.88 1.8496E-07 CS-134
- 2.
604.71 5.9089E-08 CS-137
- 5.
661. 66 9.4095E-08