ML20028C959

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept DR-84 Re Linear Indication in Root Area of Fillet Weld for Lug on One Safety Relief Valve Quencher.Review Ongoing.Interim or Final Status Rept Will Be Submitted by 830204
ML20028C959
Person / Time
Site: River Bend Entergy icon.png
Issue date: 01/05/1983
From: Booker J
GULF STATES UTILITIES CO.
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, DR-84, RBG-14-079, RBG-14-79, NUDOCS 8301140346
Download: ML20028C959 (1)


Text

[-

. m l :.

- GULF - STATES UTILITIES ' COMPANY P O S T O F FIC E B O X 2 9 51 : . O E A U M o N T, T E X A S 7 7 7 0 4 A R E A C O D E 7.13 838-6631

%,g@_M_B\V/ X3 jj- I i

January 5,1983 A 101983- { RBG-1L,079

[\_ id File N.is. G9.5, G9.25.1.1 Mr. John T. Collins, Regional Administrator-U.- S. Nuclear Regulatory Commission Region IV, Office of Inspection:and Enforcement 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011

Dear Mr. Collins:

River Bend Station Unit 1 Docket No. 50-458 Interim Report /DR-84 On December 6, 1982, Gulf States Utilities Company (GSU) notified the Nuclear Regulatory Commission's Region IV.

Office of a condition potentially reportable under 10CFR50.55(c) concerning linear indication.found in the root area of a fillet weld for a lug on one SRV quencher.(DR-84).

GSU has not completed its review at this time. An interim or final status report will be submitted by February 4, 1983.

Sine rely, .

hJ.E.Booer i Manager-Engineering, Nuclear Fuels & Licensing River Bend Nuclear Group JE J /kt cc: Director of Inspection & Enforcement U. S. Nuclear Regulatory Commission h" Washington, D. C. 20555 R. L. Brown (SRI)'

'~

8301140346 830105 PDR ADOCK 05000450 S PDR