RBG-44423, Monthly Operating Rept for Feb 1998 for River Bend Station Unit 1

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Feb 1998 for River Bend Station Unit 1
ML20216E000
Person / Time
Site: River Bend Entergy icon.png
Issue date: 02/28/1998
From: King R, Williamson D
ENTERGY OPERATIONS, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
RBF1-98-0069, RBF1-98-69, RBG-44423, NUDOCS 9803170387
Download: ML20216E000 (4)


Text

1 e

~Entergy

~

Ent:rgy Oper:_ti:ns, Inc.

River Bend Stabon 6485 U. $ Hig*iway 61 PO. Box 220 u=:r -

Fax 604 635 5068 Rick J. King Dvector Nur.ie.ar Oafety & Regulato y Aff airs March 11,1998 U.S. Nuclear Regulatory Commission Document Control Desk, OPI-17 Washington, DC 20555

Subject:

River Bend Station - Unit 1 Docket No. 50-458 Monthly Operating Report File No. G9.5, G4.25 RBG-44423 RBF1-98-0069 Ladies and Gentlemen:

In accordance with River Bend Station (RBS) Technical Specification 5.6.4, enclosed is the February,1998 Monthly Operating Report for RBS.

Sincerely,

,. s c *

,y ,

RJK/DLM/ dim enclosure

/ ,

9003170387 900228 PDR ADOCK 05000458 R PDR llllllllll{lllfhlh

~

L ~1 l .

l- ..

l I:, - '.. .

- Monthly Operating Report March 11,1998 RBG-44423 RBF1-98-0069 -

Page 2 of 2

, cc: U. S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington,TX 76011 i

NRC Senior Resident insptor P.O. Box 1050 St.Francisville,LA 70775 INPO Records Center

-700 Galleria Parkway.

Atlanta, GA 30339 3064 Mr. Jim Callowaf Public Utility Commission of Texas 1701 N. Congress Ave.

Austin, TX 78711-3326 Dottie Sherman American Nuclear Insurers 29 South Main Street West Hartford, CN 06107 l

I

DOCKET NO. 50/458 RIVER BEND STATION UNIT 1 DATE March 9,1998 COMPLETED HY !)anny H. Williamson TITLE Technical Specialist IV TELEP110NE 504-381-4279 PAGE 1 OF 2 MONTH February 1998 OPERATING STATUS

1. REPORTING PERIOD: February 1998
2. MAXIMUM DEPENDABLE CAPACITY (MWe-Net): 936
3. DESIGN ELECTRICAL RATING (MWe-Net): 936 MONTH YEAR TO CUMULATIVE i DATE
4. NUMHER OF HOURS REACTOR WAS CRITICAL 672.0 1416.4 81696 4
5. IlOURS GENERATOR ON LINE 672.0 1416.0 78381.6 l 6. UNIT RESERVE SilUTDOWN 110URS 0 0 0 .

i l

l 7. NET ELECTRICAL ENERGY GENERATED (MWH) 639,117 1,346,353 68,236,169 l

l l

l

i

..- l

~ . .. ,

PAGE 2 OF 2 1 l

l UNIT SHUTDOWNS 1

SHUTDOWN CAUSE/

NUMBER DATE TYPE DURATION MET HOD REASON CORRECTIVE ACTIONS I (none) .

I LECD D: {

i TYPE: F. Forced SillfTDOWN MFTilOD: I Manual REASON: A - Equipment failure (explain)

S Scheduled 2 - Manual trip / scram B Maintenance or Test 3- Automatic trip / scram C- Refueling l 4 Continuation D - Regulatory restriction l 5 Other(espieln) E Operator training / License es :n i F Administrative G Operationalerror(esplain)  !

11 Other(explain) l NOTES:

1. No challenges to reactor safety-relief valves occurred in February.

% %J A l Danny H. Williamson l

l l

l