GULF STATES UTILITIES COMPA' }((jy(W,(}\Ylh.m POST OFFICE a o x 2 9 51

  • OEAUMoNT, TEXAS 7? j AREA CooE 713 838-0631 nW L' -

.g(g August 30 , 1982 RBG- 13,2 a File Nos . G') . 5, G') . 25.1.1 Mr. John T. Collins, Regional Administrator U. S. Nuclear Regulatory Commission Region IV, Office of Inspection and Enforcement 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011

Dear Mr. Collins:

River Bend Station Unit 1 Docket No. 50-458 Interim Report /DR-63 On June 29, 1982, Gulf States Utilities Company (GSU) notified the Nuc1 car Regulatory Commission's Region IV Office of a condition potentially reportable under 10CFR50.55(e) concerning Velan Engineering LTD supplied

' valve studs material not recognized for use under ASME Section III (DR-63).

GSU's investigation is not completed at this time. An interim or final status report will be submitted by October 14, 1982.

Sincerely,

, J. E. Booker l

Manager-Engineering & Licensing -

[ River Bend Nuclear Group JEB/ /kt cc: Director of Inspection & Enforcement U. S. Nuclear Regulatory Commission L'ashington , D, C. 20555 l

R. L. Brown (RRI)

I v 4

/