Forwards Response to IE Bulletin 79-03A, Longitudinal Weld Defects in ASME SA-312,Type 304 Stainless Steel Pipe. No Applications of Specified Pipe at Greater than 85% Max Allowable Stress at Facility
ML20002B717
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 08/04/1980
From: William Jones
OMAHA PUBLIC POWER DISTRICT
To: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
IEB-79-03A, IEB-79-3A, NUDOCS 8012220607
Download: ML20002B717 (2)


Text

, . .

CENTRAL FILES A PDR:HQ LPDR TIC M- NSIC ma Omaha Public Power District STATE 1623 MARNEY OMAMA. NESRASKA 68102 TELEPHONE S36-4000 AREA CODE 402 August 4, 1980 Mr. K. V. Seyfrit, Director U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region IV 611 Ryan Plaza Drive Suite 1000 Arlington, Texas 76011

Reference:

Docket No. 50-285

Dear Mr. Seyfrit:

The Omaha Public Power District received IE Bulletin 79-03A, dated April 4,1980, regarding longitudinal weld defects in stainless steel piping. Attached hereto is the result of the District's review for the Fort Calhoun Station in response to the bulletin.

Sincerely,

\

f; im,. l ' ',z .

I

  • W. C. Jones Division Manager Production Operations WCJ/KJM/BJH/PRT:jmm Attachment cc: U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Washington, D. C. 20555 LeBoeuf, Lamb. Leiby & MacRae 1333 New Hampshire Avenue, N. W.

Washington, D. C. 20036 l

l l

013E

~

  • ,.'. Attachment RESPONSE TO IE BULLETIN 79-03A FOR FORT CALHOUN STATION Recuest el Determine whether SA-312 or A-312, Type 300 Series fusion welded pipe is in use or planned for use in safety-related systems subject to design stresses greater than 85 percent of the Code allcwable stresses. For the purpose of this check the actual wall thickness of the piping products will be considered adequate if the code requirements for pressure design of the piping products are satisfied using 85 percent of the maximum allowable stress at the design temperature.

Resconse #1 Stress calculations were performed for all SA-312 and A-312 Type 300 Ser-ies piping used at the Fort Calhoun Station. Of these, none were found to be above 85% of the maximum allowable stress.

Reouest #2 For those piping components using greater than 85 percent of the allowable stresses, identify the application of the piping including the system, pipe location, pipe size, pipe configuration (elbow, tee),. design pressure /

temperature requirements and the manufacturer.

Resconse #2 At the Fort Calhoun Station there are no applications of SA-312 or A-312, Type 300 series pipe at greater than 85% of the maximum allowable stress.

Recuest #3 For those facilities under construction and where access permits, the ends of all safety-related SA-312 and A-312 fusion welds should be etched to .

determine if CLP exists. Identify the manufacturer and the degree of CLP as a percentage of the pipe wall thickness.

Resoonse 43 Not applicable.

The Fort Calhoun Station does not employ any of the piping in question.

Therefore,'no further action is required in response to this IE Bulletin.