ML19338F471

From kanterella
Jump to navigation Jump to search
LER 80-032/01P-0:on 801014,during Core Spray Sparger Visual Insps,Semicircular Linear Indication Was Observed on End Face of Junction Box on C Core Spray Sparger.Cause Not Determined.Investigations Are in Progress
ML19338F471
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 10/14/1980
From: Murphy W
VERMONT YANKEE NUCLEAR POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19338F466 List:
References
LER-80-032-01P, LER-80-32-1P, NUDOCS 8010200404
Download: ML19338F471 (1)


Text

( Y

\

.. LICENSEE EVENT REPORT LER 80-32/1P CCNTROL BLOCK: l l

l l l l l lh 6

(PLEASE P7. INT 03 TYPE ALL REQUIREO INFORM ATIONI

.1011l 7 8 9 l V I LICENSEE T l V CODE l Y ! S14l 1 l@l 010 l- 10 16 l010 l 0 l 0 l- l0-10 LICENSE NUMBER 26 l@l4 26

-l1 l1 l1 l1 l@lb7 CAT LICENSE TYPE JG l

68 l@

CON'T 10111 $$

Ret l L j@l 0 l 5 l 010 l 0 l 2 l 711 l@l 110 l114 l 8 74lo l@l1 75 l0 l11418 lo80l@

> 8 60 - 61 DOCKET NUMBER - 66 ,69 EVENT OATE REPORT DATE EVENT OESCRIPTION ANO PROBABLE CONSEQUENCES h lo l2l l During perfort::ance of Core Spray Sparger Visual Inspections in accordance with NRC l l o ,3 ; jIE Bulletin 80-13, a semi-circular linear indication was observed on the end face of l

[o l4 ; l the junction box on the "C" Core Spray Sparger. l-10 i s t 1 -

I  !

} 1016 I l l

$ 10171 l l-4

, l 0 l8 l l  !'

80 "

7 s9 E CODE S 8C E COVPONENT CODE SUB ODE SU E l"OTil l S i rl@ lx i@ g@ I Pl 1l PI El xl xi@ I Bj@ g @

10 12 13 16 20 7 8 9 11 19 SEOUENTIAL OCCURRENCE REPORT REVISION LER/RO EVENT YE AR ' EPcRT NO. CODE TYPE No.

@ ,Rg l21 8l 0l

_ 22

[ _j 23 l 0l 3l 2l 24 26 l/l 27 l 01 -1 l M M lP l 30 l-l 31

@32 K f7 AC O O PL NT MET HOURS S8 IT FOR 8. SU Li MANUF C RER i

[X_,j@1l@

33 34 l35Z l@ lZ 36 l@ l0l0l0l0l 37 40 lN 44 l@ W@

42 l43Nl@ lR l3 l8 l047-l@

44 CAUSE OESCRIPTION ANO CORRECTIVE ACT'ONS h 1

. lil0lIThe cause of this event is' presently unknown. Investigations concerning the nature l l1 Ii i l of the observed indication are in progress, and additional information detailing the i

,1 ,7i l cause and corrective actions taken will be provided in the follow-up report. I 4

li t al l I l i 14 I I I 80 7 s 9

$A US  % POWER oTHER STATUS DIS / Y DISCOVERY DESCRIPTION i- 'I1 15l-(,H_,,j @ l 0l 0l 0l @ l NA l lCl@l_VisualinspectionperIEBul.80-13 l 7 sg, ig 12 n 44 as 46 so RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE NA NA l l1 l 869 l l Z l @D oF RELEASE lZ l@l44 7

10 11 l l 45 to PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION NA l

. 11171 l 0 l 0 l 0 l@l Z l@l PE RSONNE L INJU IES NUMBER DESCRIPTION y l0l0l0l@l NA 80 l

7 8 9 11 12

' T YP E DESCR PT ON 1 9 NA l 8'9

@l10 SD 7 .

NRC USE ONLY 8010200 &[6 jNA lllllllllllll}

ISSUE l @DE CRIPTION 2 o [ N_j l 7 8 9 10 68 69 80 ;

~ ~

NAME OF PREPARER

  • E PHONE:

__ _. - _ _ _. ~ - . . _ .