Responds to IE Bulletin 80-09, Hydramotor Actuator Deficiencies. Licensee Does Not Utilize Actuator Models in safety-related Applications
ML19326D724
Person / Time
Site: Clinton  Constellation icon.png
Issue date: 06/13/1980
From: Wuller G
ILLINOIS POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
IEB-80-09, IEB-80-9, NUDOCS 8007030215
Download: ML19326D724 (1)


Text

<

Tlb U-0146 ILLINOIS POWER COMPANY (*~,7. .] . L08-80(06-13)-0 v ~.

l" I 500 SOUTH 27TH STREET, DECATUR ILUNOIS 62525 June 13, 1980 U.S. Nuclear Regulatory Commission Director of Reactor Construction Inspection .

Office of Inspection & Enforcement Washington, D.C. 20555

Dear Sir:

Reference:

IE Bulletin No. 80-09, "Hydramotor Actuator Deficiencies," April 17, 1980 Clinton Power Station Units 1 & 2 Docket has. 50-461 and 50-462 Construction Permits No. CPPR-137 & -138 This is in reply to the letter of April 17 from Mr. J. G. Keppler, Director-NRC Region III, whereby the referenced IE Bulletin was forwarded for action. IE Bulletin No. 80-09 rec uired a determina-tion of applications of ITT General Controls Moc els All-90 and NH-90 Series Hydramotor Actuators in safety-related service.

Please be advised that the Clinton Power Station has none of the aforementioned actuators in safety-related applications.

Sincerely,

. M G. E. Wuller Supervisor-Licensing Generation Engineering Dept.

GEW:d1 cc: J. G. Keppler, Director-Region III, NRC ^ =

H. H. Livermore, NRC Clinton Resident Inspector l

l l

l l