Text

bec to DAC:ADM:

,, '. . CENTRAL FILES

. N. PDR:HQ

. --Egg y LPDR

'-_k'f NSIC Omaha Public Power District ' M'

. STATE 1823 HARNEY e O M AN A. NESRASMA 68102 s TELEPHONE 536 4000 AREA CODE 402 May 22, 1980 Mr. K. V. Seyfrit, Director U. S. Nuclear Regulatory Comission Office of Inspection and Enforcement Region IV 611 Ryan Plaza Drive Suite 1000 Arlington, Texas 76011

Reference:

Docket No. 50-285

Dear Mr. Seyfrit:

The Omaha Public Power District received IE Bulletin 80-09, dated April 17, 1980, regarding deficiencies with ITT Oeneral Controls, Models AH-90 and NH-90 Series Hydramotor Actuators.

The District has reviewed all appropriate documentation and the results indicate that none of the actuators in question are in-stalled at the Fort Calhoun Station Unit No. 1. Accordingly, the District considers all actions required by IE Bulletin 80-09 complete.

~

Sincerely, ie W. C. Jones Division Manager Production Operations WCJ/KJM/BJH/TLP:Jmm ec: U. S. Nuclear Regulatory Comission Office of Inspection and Enforcement

)