ML19158A272

From kanterella
Jump to navigation Jump to search

Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM Flood-Wind Multipurpose Canister Storage System, Amendment No. 4
ML19158A272
Person / Time
Site: 07201032
Issue date: 12/20/2019
From: Dan Doyle
Spent Fuel Licensing Branch
To: Jason Cai
NRC/NMSS/DREFS/ERMB
Chen Y
Shared Package
ML19158A271 List:
References
CAC 001208, EPID L-2017-LLA-0030
Download: ML19158A272 (3)


Text

December 20, 2019 MEMORANDUM TO: June Cai, Chief Materials Rulemaking and Project Management Branch Division of Rulemaking, Environmental, and Financial Support Office of Nuclear Material Safety and Safeguards FROM:

Daniel I. Doyle, Acting Chief

/RA/

Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards

SUBJECT:

USER NEED FOR RULEMAKING FOR THE HOLTEC HI-STORM FLOOD/WIND MULTIPURPOSE CANISTER STORAGE SYSTEM, AMENDMENT NO. 4 The purpose of this communication is to request support for rulemaking activities in the Division of Fuel Management (DFM) for the following Title 10 of the Code of Federal Regulations (10 CFR) Part 72 licensing action:

1.

Changes to 10 CFR 72.214 rule text (changes appear in bold):

Certificate Number: 1032.

Initial Certificate Effective Date: June 13, 2011, superseded by Amendment Number 0, Revision 1, on April 25, 2016.

Amendment Number 4 Effective Date: [insert 75 days from date of Federal Register publication].

SARs Submitted by: Holtec International.

SAR

Title:

Final Safety Analysis Report for the HI-STORM FW System.

Docket Number: 72-1032.

Certificate Expiration Date: June 12, 2031.

Model Numbers: HI-STORM FW MPC-32ML, MPC-37, and MPC-89.

2.

By letter dated March 11, 2016, and as supplemented on September 16, 2016, January 31, 2017, April 27, 2018, July 27, 2018, April 12, 2019, June 11, 2019, and July 5, 2019, Holtec International submitted an amendment request to the U.S. Nuclear Regulatory Commission for the HI-STORM Flood/Wind Multipurpose Canister Storage System Certificate of Compliance (CoC) No. 1032. The proposed changes include the following:

CONTACT:

Yen-Ju Chen, NMSS/DFM (301) 415-1018

1) Add MPC-32ML for storage in HI-STORM FW system and allow fuel assembly class 16x16D as content for MPC-32ML.
2) Add fuel assembly class 16x16E as content for MPC-37.
3) Separate the design pressure for the short-term operation from the off normal condition to provide clarity in final safety analysis report (FSAR) Table 2.2.1.
4) Add a caution note in FSAR Section 9.2.1 that states fuel cladding is not exposed to air during loading operations.
5) Update the definition of undamaged fuel assembly in FSAR Glossary to be aligned with the definition in Appendix A and FSAR Table 2.1.3 (Note 14).
6) Replace Charpy test program with fracture toughness test program from the revised Metamic-HT Sourcebook (Holtec, 2017b) in FSAR Sections 1.2.1.4.1 and 3.4.
7) Add a caution note in FSAR Section 9.2.3 that states low-enriched fuel must be shown to be without known or suspected grossly breached rods.
3.

The proposed CoC, CoC Appendix ATechnical Specifications, CoC Appendix B Approved Contents and Design Features, and preliminary safety evaluation report (SER) have been placed in ADAMS (see references below) and are available for your use in the rulemaking package. DFM will designate these documents as Official Agency Records after the Executive Director for Operations has approved the package (ADAMS Package No. ML19158A271).

The Office of the General Counsel has reviewed this memorandum with its referenced documents and has no legal objection to its contents.

DOCKET No.: 72-1032 CAC No.: 001028 EPID: L-2017-LLA-0030 ADAMS

References:

1. Proposed CoC 1032 Amendment No. 4 (ML19158A273)
2. Proposed CoC 1032 Amendment No. 4 Appendix A (ML19158A274)
3. Proposed CoC 1032 Amendment No. 4 Appendix B (ML19158A275)
4. Preliminary CoC 1032 Amendment No. 4 SER (ML19158A276)

Package: ML19158A271, Memo: ML19158A272

  • concur by email OFFICE DFM DFM OGC DFM NAME YChen WWheatley*

LClark*