ML20329A323

From kanterella
Jump to navigation Jump to search

International, Clarification RAI Responses on HI-STAR 100 License Renewal Updated
ML20329A323
Person / Time
Site: 07201008
Issue date: 11/24/2020
From:
Holtec
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20329A321 List:
References
5014914
Download: ML20329A323 (99)


Text

Certificate of Compliance Renewal Application for the HI-STAR 100 Dry Storage System Certificate of Compliance No. 1008, Docket Number 72-1008

ATTACHMENT 1 TO HOLTEC LETTER 5014914 1 of 99

Table of Contents Chapter 1 - General Information Chapter 2 - Scoping Evaluation Chapter 3 - Aging Management Review Chapter 4 - Aging Management Tollgates Appendices A - HI-STAR 100 AMPs B - TLAAs C - Canister Inspections D - Aging Management FSAR Changes E - Aging Management CoC Changes

ATTACHMENT 1 TO HOLTEC LETTER 5014914 2 of 99

Revision Summary Revision 0 - Initial Issue Revision 1 - Incorporation of Users Group comments throughout document Proposed Revision 1.A - Incorporation of responses to NRC RSIs Proposed Revision 1.B - Supplemental information to NRC RSIs Proposed Revision 1.C - Responses to NRC RAIs Proposed Revision 1.D - Responses to NRC 2nd Round RAIs

ATTACHMENT 1 TO HOLTEC LETTER 5014914 3 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.DA 1-1 CHAPTER 1: GENERAL INFORMATION 1.0 Introduction The HI-STAR 100 System Certificate of Compliance (CoC) No. 72-1008 was first approved for storage of spent nuclear fuel by the NRC on October 4, 1999, under the provisions of 10CFR 72 for use by general licensees, and therefore expires October 4, 2019. In accordance with 10 CFR 72.240(a) and as the certificate holder of CoC 1008, Holtec International is applying for a renewal of CoC 1008 for an additional term of 40 years.

This renewal application includes the Safety Analysis Report (SAR) information required by 10 CFR 72.240(c). The content of this application is based on the guidance provided in NUREG-1927 [1.0.1].

Additional guidance on content and format of this application is also provided in NEI-14-03 [1.0.2].

In accordance with the guidance in NUREG-1927, this renewal application is based on the continuation of the existing licensing basis throughout the period of extended operation and is based on maintaining the intended safety function of the structures, systems, and components (SSCs) important to safety. The existing licensing basis for the HI-STAR 100 system, consists primarily of:

a. CoC 1008 including appendices for each approved amendment
b. Safety Evaluation Reports (SERs) issued for each approved amendment
c. The Final Safety Analysis Reports corresponding to each approved amendment
d. Any other Docketed Licensing Correspondence, as applicable Exemption Requests granted to individual sites should be considered part of that specific sites licensing basis.

This renewal application also includes appendices summarizing the aging management programs (AMPs),

time-limited aging analyses (TLAA), as well as the changes needed to the HI-STAR 100 FSAR and CoC to address the aging management of the system.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 4 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.DA 1-2 1.1 HI-STAR 100 System Description This section provides a brief description of the HI-STAR 100 storage system. Full details of the system are contained in the FSAR [1.1.1] referenced herein.

1.2.1 General System Description The HI-STAR 100 system is a canister based system for the storage of spent nuclear fuel comprised of two discrete components: the multi-purpose canister (MPC), and the storage/transport overpack. Other auxiliaries including lifting and handling systems, welding equipment, drying system, and transporter are required to deploy the HI-STAR 100 system for storage.

1.2.2 Principle Components of the HI-STAR 100 System 1.2.2.1 Multi-Purpose Canister (MPC)

The HI-STAR 100 MPCs are welded cylindrical structures with flat ends. Each MPC is an assembly consisting of a honeycombed fuel basket, a baseplate, canister shell, a lid, and a closure ring. The outer diameter and cylindrical height of each MPC is fixed. However, the number of spent nuclear fuel storage locations in each of the MPCs depends on the fuel assembly characteristics.

The MPC provides the confinement boundary for the stored fuel. The confinement boundary is a seal-welded enclosure constructed entirely of stainless steel.

The construction features of the PWR MPC-24, PWR MPC-32, and the BWR MPC-68 are similar.

However, the PWR MPC-24 canister, which is designed for highly enriched PWR fuel without credit for soluble boron, differs in construction from the MPC-32 or MPC-68 in one important aspect. The fuel storage cells are physically separated from one another by a flux trap between each storage cell for criticality control. All MPC baskets are formed from an array of plates welded to each other, such that a honey comb structure is created which resembles a multiflanged, closed-section beam in its structural characteristics. MPC-32 contains a non-flux trap (NFT) fuel basket for PWR fuel.

The MPC Fuel basket is positioned and supported within the MPC shell by basket shims located in the space between the inside of the MPC shell and the Fuel Basket. Between the periphery of the basket, the MPC shell, and the basket supports, heat conduction elements are optionally installed. The heat conduction elements are installed along the full length of the MPC basket, except at the drain pipe location, to create a nonstructural thermal connection which facilitates heat transfer from the basket to shell. In their operating condition, the heat conduction elements will conform to and contact the MPC shell and basket walls.

Lifting lugs attached to the inside surface of the MPC canister shell serve to permit lifting and placement of the empty MPC into the overpack. The lifting lugs also serve to axially locate the lid prior to welding.

These internal lifting lugs are not used to handle a loaded MPC. Since the MPC lid is installed prior to any handling of the loaded MPC, there is no access to the lifting lugs once the MPC is loaded.

The top end of the HI-STAR 100 MPC incorporates a redundant closure system. The MPC lid is a circular plate edge-welded to the MPC outer shell. This lid is equipped with vent and drain ports which are utilized to remove moisture and air from the MPC, and backfill the MPC with a specified pressure of inert gas ATTACHMENT 1 TO HOLTEC LETTER 5014914 5 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.DA 1-3 (helium). The vent and drain ports are covered and welded before the closure ring is installed. The closure ring is a circular ring edge-welded to the MPC shell and lid. The MPC lid provides sufficient rigidity to allow the entire MPC loaded with SNF to be lifted by threaded holes in the MPC lid.

For fuel assemblies that are shorter than the design basis length, upper and lower fuel spacers (as appropriate) maintain the axial position of the fuel assembly within the MPC basket.

The MPC is constructed entirely from stainless steel alloy materials (except for the neutron absorber and aluminum heat conduction elements). No carbon steel parts are permitted to be in contact with the pool water in the MPC. All structural components in an MPC shall be made of Alloy X, a full description of Alloy X is contained in the HI-STAR 100 FSAR [1.1.1].

1.2.2.2 HI-STAR 100 Overpack The HI-STAR 100 overpack is a heavy-walled steel cylindrical vessel. The overpack helium retention boundary is formed by an inner shell welded at the bottom to a cylindrical forging and, at the top, to a heavy main flange with a bolted closure plate. Two concentric grooves are machined into the closure plate for self-energizing seals. The closure plate is recessed into the top flange and the bolted joint is configured to provide maximum protection to the closure bolts and seals in the event of a drop accident. The closure plate has a vent port which is sealed by a threaded port plug with a seal. The bottom plate has a drain port which is sealed by a threaded port plug with a seal. The inner surfaces of the HI-STAR overpack form an internal cylindrical cavity for housing the MPC.

The outer surface of the overpack inner shell is buttressed with intermediate shells of gamma shielding which are installed in a manner to ensure a permanent state of contact between adjacent layers. Besides serving as an effective gamma shield, these layers provide additional strength to the overpack to resist potential punctures or penetrations from external missiles. Radial channels are vertically welded to the outside surface of the outermost intermediate shell at nominally equal intervals around the circumference.

These radial channels act as fins for improved heat conduction to the overpack outer enclosure shell surface and as cavities for retaining and protecting the neutron shielding. The enclosure shell is formed by welding enclosure shell panels between each of the channels to form additional cavities. Neutron shielding material is placed into each of the radial cavity segments formed by the radial channels, the outermost intermediate shell, and the enclosure shell panels. The exterior flats of the radial channels and the enclosure shell panels form the overpack outer enclosure shell. Atop the outer enclosure shell, rupture disks are positioned in a recessed area. The rupture disks relieve internal pressure which may develop as a result of the fire accident and subsequent off-gassing of the neutron shield material. Within each radial channel, a layer of silicone sponge is positioned, if required, to alleviate the thermal stresses from differential expansion.

The exposed steel surfaces of the overpack are coated with paint to prevent corrosion. The paint is described in detail in the HI-STAR 100 FSAR [1.1.1]. The inner cavity of the overpack is coated with a paint appropriate to its higher temperatures and the exterior of the overpack is coated with a paint appropriate for fuel pool operations and environmental exposure.

Lifting trunnions are attached to the overpack top flange forging for lifting and for roating the cask body between vertical and horizontal positions. The lifting trunnions are located 180o apart in the sides of the top flange. Pocket trunnions, if used, are welded to the lower side of the overpack to provide a pivoting ATTACHMENT 1 TO HOLTEC LETTER 5014914 6 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.DA 1-4 axis for rotation. The pocket trunnions are located slightly off-center to ensure the proper rotation direction of the overpack. The lifting trunnions do not protrude beyond the cylindrical envelope of the overpack enclosure shell. This feature reduces the potential for a direct impact on a trunnion in the event of an overpack side impact.

1.2.2.3 Other Structures, Systems, and Components Fuel Assemblies The HI-STAR 100 system is designed to store spent fuel assemblies as described in Chapter 2 of the HI-STAR 100 FSAR [1.1.1], and authorized in Appendix B of the CoC.

Fuel Transfer and Auxiliary Equipment Auxiliary equipment used for loading of MPCs and cask movement (e.g., drying system, cask transporter, welding equipment, etc.) are not included as part of the HI-STAR 100 CoC, and as such are not described in detail in the FSAR, nor are they within scope for aging management.

ISFSI Pad The pad is a reinforced concrete structure where the HI-STAR 100 casks are stored. Beginning with Amendment 2 of the HI-STAR 100 CoC, the ISFSI Pad is not a licensed component, of the HI-STAR 100 System. The CoC requirement is that the cask storage pad be verified by analysis to limit cask deceleration during both the design basis drop and non-mechanistic tipover event to 60 gs at the top of the MPC fuel basket. These analyses shall be performed using methodologies consistent with those described in the HI-STAR 100 FSAR. Previous amendments of the CoC required specific pad properties in the CoC to be met by the users to ensure that the cask deceleration was within limits.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 7 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.DA 1-5

1.3 Background

The HI-STAR 100 System was originally approved by the NRC on October 4, 1999. Subsequently amendments 1 and 2 were approved by the NRC, with a 3rd amendment currently under NRC review. These amendments were requested by Holtec International to address continuing needs of utilities to store different types of PWR or BWR fuel, with revised heat loads, enrichments, or other parameters. The HI-STAR 100 cask is also approved for transportation under 10 CFR Part 71, but that CoC is not part of this storage renewal application.

Table 1.3-1 lists each of the approved HI-STAR 100 storage amendments. The table provides a description of the scope of the amendment, its approval time, identification of the FSAR which provides the licensing basis, and a pointer to where the AMPs for different amendments are located in this application. Note, that because the FSAR is updated for each amendment, the latest FSAR contains the full licensing basis for all previous amendments.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 8 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.DBA 1-6 Table 1.3-1: HI-STAR 100 CoC Amendments Amendment Number Description of Changes Approval Date Original FSAR Basis Location of Aging Management Program (AMP) 0 Initial Issue 10/4/1999 HI-2012610, Rev 0 Appendix A 1

Revisions to limits for existing fuel array/classes Addition of PWR Burnable Poison Rod Assemblies (BPRAs) and Thimble Plug Devices (TPDs)

Addition of two new fuel assembly array/classes Addition of a new damaged fuel container (DFC)

Addition of thoria rods in canisters Addition of antimony-beryllium neutron sources 12/26/2000 HI-2012610, Rev 0 Appendix A 2

Modification to the specifications for the cask pad and foundation.

5/29/2001 HI-2012610, Rev 3 Appendix A 3

Addition of MPC-32 Addition of Metamic neutron absorber Revision of confinement boundary leak tight criterion Addition of soluble boron credit Pocket trunnions revised as optional Addition of Forced Helium Dehydration (FHD) option Allow horizontal storage of the HI-STAR 100 casks Align fuel cladding temperature limits with ISG-11 Rev 3 11/5/2019 HI-2012610, Rev 4 Appendix A ATTACHMENT 1 TO HOLTEC LETTER 5014914 9 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.D 1-7 1.3 References

[1.0.1]

NUREG-1927, Standard Review Plan for Renewal of Specific Licenses and Certificates of Compliance for Dry Storage of Spent Nuclear Fuel, Revision 1. US NRC, June 2016.

[1.0.2]

NEI 14-03, Format, Content and Implementation Guidance for Dry Cask Storage Operations-Based Aging Management, Revision 2, December 2016

[1.1.1]

HI-2012610, HI-STAR 100 FSAR, Revision 3, October 2013 ATTACHMENT 1 TO HOLTEC LETTER 5014914 10 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 2-1 CHAPTER 2: SCOPING EVALUATION 2.0 Introduction Chapter 2 describes the evaluation process and methodology used to identify the structures, systems, and components (SSCs) of the HI-STAR 100 System and the subcomponents thereof that are within the scope of the license renewal.

2.1 Scoping Evaluation Process and Methodology The scoping evaluation of the HI-STAR 100 System is performed based on the two-step process described in NUREG-1927 [1.0.1]. The first step in the process is a screening evaluation to determine which systems, structures, and component (SSC) are within the scope of the license renewal, and then the in scope components are reviewed to determine the need for aging management activities. Per NUREG-1927, Section 2.4.2, structures, systems, and components (SSC) are considered to be within the scope of the renewal if they satisfy either of the following criteria:

1) They are classified as Important-To-Safety (ITS), as they are relied on to do one of the following functions:
i. Maintain the conditions required by the regulation or CoC to store spent fuel safely; ii. Prevent damage to the spent fuel during handling and storage; or iii. Provide reasonable assurance that spent fuel can be received, handled, packaged, stored, and retrieved without undue risk to the health and safety of the public.

These SSCs ensure that important safety functions are met for (1) confinement, (2) radiation shielding, (3) sub-criticality control, (4) heat-removal capability, (5) structural integrity, and (6) retrievability

2) They are classified as Not-Important-To-Safety (NITS), but, according to the design bases, their failure could prevent fulfillment of a function that is ITS.

Any SSC that meets either Scoping Criterion 1 or 2 above is considered within the scope of license renewal (in-scope), and the function(s) it is required to perform during the extended term is identified. The results of the scoping evaluation are presented in Section 2.2.

As stated above, the HI-STAR 100 renewal is based on the continuation of the existing Current Licensing Basis (CLB) throughout the period of extended operation and maintenance of the intended safety functions of the SSC ITS. Accordingly, the sources of information reviewed in the scoping evaluation that describe the CLB and the intended safety functions of the SSC ITS are the HI-STAR 100 FSAR ([2.1.1]) and CoC ([2.1.2], [2.1.3], and

[2.1.5]).

2.2 Results of Scoping Evaluation As discussed in Section 1.2, the HI-STAR 100 system includes the following major components:

MPC ATTACHMENT 1 TO HOLTEC LETTER 5014914 11 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 2-2 HI-STAR 100 Overpack Fuel Assembly ISFSI Pad Fuel Transfer and Auxiliary Equipment The following sections include brief descriptions of the components, detailed descriptions can be found in Reference [2.1.1]. Table 2.1-1 summarizes the results of the scoping evaluation, listing the SSC that are identified as within scope and the criteria upon which they are determined to be within scope. There are no other components identified as part of the generically licensed HI-STAR 100 system.

2.2.1 Description of SSC 2.2.1.1 MPC The MPC (including fuel basket) is constructed primarily of stainless steel, with supplemented Metamic or BoralTM neutron absorbers (Metamic was added as an option in the submittal of Amendment 3, and is therefore included in this license renewal). The primary functions of the MPC (including fuel basket) are confinement, criticality control, heat transfer, and shielding. The MPC is classified as ITS-A.

2.2.1.2 HI-STAR 100 Overpack The HI-STAR 100 overpack provides helium retention for heat rejection and gamma and neutron shielding for the HI-STAR 100 system. The overpack consists primarily of a welded carbon steel cavity with a bolted carbon steel closure lid. Intermediate and enclosure carbon steel shells and Holtite-A comprise the majority of the overpack body. The primary functions of the overpack are structural integrity and shielding. The overpack is classified as ITS-A.

2.2.1.3 Fuel Assembly The HI-STAR 100 system is designed to store spent fuel assemblies as described in Chapter 2 of the HI-STAR 100 FSAR [2.1.1]. Parts of the fuel assembly have the functions of criticality control, radiation shielding, confinement, and structural integrity.

2.2.1.4 ISFSI Pad The ISFSI Pad is a facility within the perimeter fence, designed for the storage of loaded HI-STAR 100 overpacks.

Though not described in detail in the FSAR, basic requirements for the storage pad are defined to ensure there is no adverse impact to the overpacks or spent fuel contained within under the conditions analyzed in the FSAR.

2.2.1.5 Fuel Transfer and Auxiliary Equipment Auxiliary equipment used for loading of MPCs and cask movement (e.g., drying system, cask transporter, welding equipment, etc.) are not included as part of the HI-STAR 100 CoC, and as such are not described in detail in the FSAR, nor are they within scope for aging management.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 12 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 2-3 2.2.2 SSCs Within the Scope of CoC Renewal The SSCs determined to be within the scope of the license renewal are the MPC, Overpack, Fuel Assembly, and the ISFSI Pad as shown in Table 2.1-1. Note that the fuel assembly hardware and cladding which supports the retrievability of the spent fuel are considered in scope.

2.2.3 SSCs Not Within the Scope of CoC Renewal As shown in Table 2.1-1, the Fuel Transfer and Auxiliary Equipment do not meet the criteria for being within scope of the license renewal. Note that the fuel pellets within the assemblies are not relied on to meet retrievability or confinement functions and are therefore not considered in this renewal application.

Sites that have site specific equipment should utilize the same scoping criteria and document the components in their 72.212 report. Note that components that are considered replaceable may be out of scope for aging management.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 13 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 2-4 Table 2.1 Summary of Scoping Evaluation Results Structure, System, or Component (SSC)

Scoping Results In-Scope SSC Criterion 11 Criterion 22 MPC Yes N/A Yes HI-STAR 100 Overpack Yes N/A Yes Fuel Assembly3 Yes N/A Yes ISFSI Pad No4 Yes Yes Fuel Transfer and Auxiliary Equipment No No No Notes:

1 SSC is Important-to-Safety (ITS) 2 SSC is Not Important-to-Safety (NITS), but its failure could prevent an ITS function from being fulfilled 3

Fuel pellets not included 4

According to the CoC and FSAR, the ISFSI Pad is NITS, some individual sites may have chosen to upgrade the safety class, but this application is for renewal of the generic CoC and FSAR.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 14 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 2-5 Table 2.1 MPC Enclosure Vessel Subcomponents Subcomponent Safety Class Intended Function Note 1 Licensing Drawing Number Shell ITS Confinement PROPRIETARY INFORMATION WITHHELD Baseplate ITS Confinement Lid (one-piece design or top portion of two-piece design)

ITS Confinement Closure Ring ITS Confinement Vent/Drain Port Cover Plate ITS Confinement Vent/Drain Shield Block ITS Shielding Plugs for Drilled Holes NITS Shielding Bottom Portion of Two-Piece Lid (if applicable)

ITS Shielding Lift Lug ITS Structural Integrity Lift Lug Baseplate ITS Structural Integrity Upper Fuel Spacer Column ITS Structural Integrity Upper Fuel Spacer Bolt NITS Structural Integrity Upper Fuel Spacer End Plate ITS Structural Integrity Lower Fuel Spacer Column ITS Structural Integrity Lower Fuel Spacer End Plate ITS Structural Integrity Vent Shield Block Spacer ITS Structural Integrity Vent/Drain Tube ITS Operations Retrievability N/A Vent/Drain Port Cap ITS Operations Retrievability N/A Vent/Drain Cap Seal Washer NITS Operations Retrievability N/A Vent/Drain Cap Seal Washer Bolt NITS Retrievability N/AOperations Reducer NITS N/AOperations Drain Line NITS N/AOperations Drain Line Guide Tube NITS N/AOperations Support Plate (for Drain Line)

NITS N/AOperations ATTACHMENT 1 TO HOLTEC LETTER 5014914 15 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 2-6 Table 2.1 MPC Enclosure Vessel Subcomponents Subcomponent Safety Class Intended Function Note 1 Licensing Drawing Number Vent and Drain Tube, Optional ITS Retrievability PROPRIETARY INFORMATION WITHHELD Threaded Disc, Plug Adjustment ITS Retrievability Vent and Drain Plug ITS Retrievability Thread Shield Cap NITS Retrievability Retaining Ring NITS Retrievability Notes

1) N/A means the component does not have a function in the period of extended operation or is NITS, and its failure does not impact an ITS component. These components are not included in the aging management review tables in Chapter 3.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 16 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 2-7 Table 2.1 MPC Basket Subcomponents Subcomponent Safety Class Intended Function Note 1 Licensing Drawing Number Basket Cell Plate ITS Criticality Control PROPRIETARY INFORMATION WITHHELD Neutron Absorber ITS Criticality Control Sheathing ITS Structural Integrity Shim NITS Structural Integrity Basket Support (Angled Plate)

ITS Structural Integrity Basket Support (Flat Plate)

NITS Structural Integrity Heat Conduction Elements ITS N/A Damaged Fuel Container ITS NA Notes

1) N/A means the component does not have a function in the period of extended operation andor is NITS, and its failure does not impact an ITS component. These components are not included in the aging management review tables in Chapter 3.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 17 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 2-8 Table 2.1 HI-STAR 100 Overpack Subcomponents Subcomponent Safety Class Intended Function Note 1 Licensing Drawing Number Inner Shell ITS Helium Retention PROPRIETARY INFORMATION WITHHELD Bottom Plate ITS Helium Retention Top Flange ITS Helium Retention Closure Plate ITS Helium Retention Closure Plate Bolt ITS Helium Retention Port Plug ITS Helium Retention Port Plug Seal ITS Helium Retention Closure Plate Seal ITS Helium Retention Port Cover Seal ITS Helium Retention Intermediate Shell ITS Shielding Neutron Shield ITS Shielding Plugs for Drilled Holes NITS Shielding Removable Shear Ring ITS Shielding Radial Channel ITS Heat Transfer Lifting Trunnion ITS Structural Integrity Pocket Trunnion Plug Plate ITS Shielding Pocket Trunnion ITS Rotation Pivot and Shielding Relief Device ITS Structural Integrity Relief Device Plate ITS Structural Integrity Removable Shear Ring Bolt ITS Structural Integrity Thermal Expansion Foam NITS N/AStructural Integrity Closure Bolt Washer NITS Structural Integrity Enclosure Shell Panel ITS Structural Integrity Enclosure Shell Return ITS Structural Integrity Port Cover ITS Structural Integrity ATTACHMENT 1 TO HOLTEC LETTER 5014914 18 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 2-9 Table 2.1 HI-STAR 100 Overpack Subcomponents Subcomponent Safety Class Intended Function Note 1 Licensing Drawing Number Port Cover Bolt ITS Structural Integrity PROPRIETARY INFORMATION WITHHELD Trunnion End Cap ITS OperationsN/A Trunnion End Cap Bolt ITS OperationsN/A Lifting Trunnion Locking Pad ITS OperationsN/A Trunnion Locking Pad Bolt ITS OperationsN/A Nameplate NITS OperationsN/A Notes

1) N/A means the component does not have a function in the period of extended operation or is NITS, and its failure does not impact an ITS component. These components are not included in the aging management review tables in Chapter 3.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 19 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 2-10 Table 2.1 Fuel Assembly Subcomponents Subcomponent Safety Class Intended Function Note 1 Licensing Drawing Number Fuel Pellets ITS N/A N/A Fuel Cladding ITS Criticality Control, Radiation Shielding, Confinement Structural Integrity, Retreivability N/A Spacer Grid Assemblies ITS Criticality Control, Structural Integrity N/A Upper End Fitting ITS Structural Integrity N/A Lower End Fitting ITS Structural Integrity N/A Guide Tubes ITS Structural Integrity N/A Hold-Down Spring & Upper End Plugs ITS N/A N/A Control Components ITS N/A N/A Notes

1) N/A means the component does not have a function in the period of extended operation or is NITS, and its failure does not impact an ITS component. These components are not included in the aging management review tables in Chapter 3.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 20 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 2-11 Table 2.1 ISFSI Pad Subcomponents Subcomponent Safety Class Intended Function Licensing Drawing Number ISFSI Pad NITS Structural Integrity N/A ATTACHMENT 1 TO HOLTEC LETTER 5014914 21 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 2-12 2.3 References

[2.1.1]

HI-STAR 100 Final Safety Analysis Report, Holtec Report No.HI-2012610, Rev 3

[2.1.2]

HI-STAR 100 Certificate of Compliance 72-1008, Amendment 0

[2.1.3]

HI-STAR 100 Certificate of Compliance 72-1008, Amendment 1

[2.1.4]

HI-STAR 100 Certificate of Compliance 72-1008, Amendment 2 ATTACHMENT 1 TO HOLTEC LETTER 5014914 22 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-1 CHAPTER 3: AGING MANAGEMENT REVIEW 3.0 Introduction The HI-STAR 100 dry storage system, US NRC Certificate of Compliance (CoC) 1008, has a life that is broken down into three classifications. The first classification, the license life of the system, is the amount of time that the system has been licensed by the NRC for use in dry storage. The second classification, a design life of 50 years is the length of time for which the storage system has been engineered to perform all of its design functions. The final classification is the minimum service life of 100 years, which is contingent upon at least two license renewals beyond the original license life.

Because the HI-STAR 100 dry storage system is nearing the end of its initial 20 year license life and the US NRC requires an aging management program be put in place in order to complete the license renewal for the next 40 year license life, this chapter presents the Aging Management Review (AMR) for the HI-STAR 100 system. The purpose of the AMR is to assess the aging effects and mechanisms that could adversely affect the ability of the system, structures, or components (SSC), determined to be within the scope of the license renewal, to perform their intended functions during the period of extended storage. The aging management program must take into account the intended function of each SSC, its material, and the environment in which it was used to determine what activities are needed. The US NRC guidance for the aging management program is contained in NUREG-1927 [1.0.1].

ATTACHMENT 1 TO HOLTEC LETTER 5014914 23 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-2 3.1 Operating Experience Review 3.1.1 Engineering Changes HI-STAR 100 change documents (ECOs) were reviewed to determine if any changes impact the need for aging management activities for the HI-STAR 100 system. This review [3.1.1] demonstrated that no additional aging management activities are required based on these change documents. Additionally, no design changes were made (other than those in the Amendment 3 application, which are considered in this renewal) since the previous biennial submittal of the FSAR [3.1.2].

3.1.2 User Operating Experience Site operating experience (OE) was reviewed to determine if there is any impact to the aging management activities of the HI-STAR 100 system. Sites performed annual external inspections in accordance with the requirements of the HI-STAR 100 FSAR. These inspections showed minor external corrosion due to general outdoor exposure, which some sites have addressed by performing repainting on the system. The aging management program for the overpack includes checking the external of the overpack for corrosion, which aligns with what the sites have experienced.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 24 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-3 3.2 Aging Management Review Methodology As described in NUREG-1927 [1.0.1], the aging management review process is broken down into a number of steps.

The first step is determining the in-scope SSC subcomponents that require aging management review, followed by identification of the aging effects requiring management, and finally identification of the necessary management activities for each affected subcomponent. Aging management activities can either be Time Limited Aging Analyses (TLAAs) or Aging Management Programs (AMPs) depending on the component material, service environment, and existing licensing basis calculations.

3.2.1 Identification of In-Scope SSCs Requiring Aging Management Review As discussed in Chapter 2, all SSC subcomponents that perform or support any of the identified, intended functions in a passive manner are in-scope for license renewal and are therefore, in-scope for aging management review.

These subcomponents are presented in Table 3.3-1 through Table 3.3-5.

Any SSC subcomponents that do not perform or support an intended function or already have their condition monitored at some established frequency are excluded from further evaluation in the aging management review.

3.2.2 Identification of Materials and Environments A detailed description of the HI-STAR 100 system and the materials used in the SSCs are described in the HI-STAR 100 FSAR [2.1.1]. A breakdown of each SSC subcomponent in-scope for aging management, with its intended function, material, and service environment is contained in Table 3.3-1 through Table 3.3-5. Note that subcomponents which do not have a safety function or support a safety function are not required to undergo aging management. A summary of the main environments is shown below. The materials used in the system are the same as those described in the draft MAPS report [3.2.1].

3.2.2.1 Helium The helium environment refers to the inside of the MPC and overpack cavity space, which are backfilled with inert helium gas. Based on the vacuum drying process, the environment has negligible amounts of oxygen or moisture.

The inert environment is exposed to the range of temperatures calculated for the MPC and overpack as well as significant radiation impacts from the stored fuel.

3.2.2.2 Sheltered Environment The term sheltered environment refers to environments that may include ambient air, but are shielded from sunlight, rain, or wind exposure. One sheltered environment would be inside a building that may not have HVAC controlled settings. The ambient air contains moisture, salinity, or other contaminants typical for the site. The temperature of the sheltered environment is within the limits of the air temperature passing through the annular space. This environment is not present in the HI-STAR 100 system.

3.2.2.3 Embedded Environment The embedded environment applies to materials that in contact with another material. Items in this environment include the internal shells of the overpack and reinforcing bars embedded in the ISFSI pad. The embedded items are exposed to the temperatures of the components in which they are embedded.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 25 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-4 3.2.2.4 Air-Outdoor Environment The term air-outdoor environment is used for exterior surfaces that are exposed to direct sunlight, wind, rain, and other weather aspects. Items in an air-outdoor environment in the HI-STAR 100 include the outer surface of the overpack. The air-outdoor, environment has temperature ranges equivalent to the site ambient temperature ranges.

A description of the subcomponent material of construction and environmental information is given in the following sections and summarized in Tables 3-1 through 3-5.

3.2.3 Identification of Aging Effects Requiring Management After the materials and environments have been identified, the next step involves determining the aging effects requiring management. Aging effects requiring management during the renewed license period are those that could cause a loss of SSC intended function. If degradation of a subcomponent would be insufficient to cause a loss of function or the relevant conditions do not exist for the aging effect to occur and propagate, then no aging management is required. These aging effects were determined based on the combination of materials and environments and a review of known literature, industry operating experience, and maintenance and inspection records. Both potential aging effects that could theoretically occur, as well as aging effects that have actually occurred based upon industry operating experience were considered.

Aging effects occur due to aging mechanisms. In order to manage aging effects, the aging mechanism that could be at work based on material and environment, must be determined. Therefore, the AMR process identifies both aging effects and the aging mechanism causing that effect. The aging effects and mechanisms for each SSC are broken down by subcomponent in Table 3.3-1 through Table 3.3-5.

3.2.4 Determination of Aging Management Activity Required The final step in the AMR process is to determine the aging management activity or program to manage the effect of aging. As much as possible, existing ISFSI programs and activities were credited to manage aging effects that could cause a loss of intended function during the renewed license period.

As described in NUREG-1927 [Ref. 1.0.1], there are two options for managing aging effects on components; a time-limited aging analysis (TLAA) or an aging management program (AMP).

3.2.4.1 Time-Limited Aging Analysis (TLAA)

A Time-Limited Aging Analysis (TLAA) is a licensee or CoC holder calculation or analysis that meets all of the following attributes, as defined in 10CFR72.3:

Involves SSCs important to safety within the scope of license or CoC renewal, Considers the effects of aging, Involves time-limited assumptions defined by the current operating term Was determined to be relevant by the licensee or CoC holder in making a safety determination Involves conclusions or provides the basis for conclusions related to the capability of the SSCs to perform their intended safety functions, and Is contained or incorporated by reference in the design bases.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 26 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-5 3.2.4.2 Aging Management Program (AMP)

An Aging Management Program (AMP) is a program conducted by the licensee or Certificate of Compliance (CoC) user for the purposes of addressing the aging effects in accordance with NUREG-1927. The program may include prevention, mitigation, condition monitoring, and/or performance monitoring. These AMPs are to be started as the HI-STAR 100 systems reach the end of their initial license life and intended to support the HI-STAR 100 systems during their renewed license periods.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 27 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-6 3.3 Aging Management Review Results 3.3.1 Aging Management Review Results - MPC Table 3.3-1 and Table 3.3-2 summarize the results of the aging management review for the MPC subcomponents previously determined to be in the scope of the license renewal.

Additional description of the MPC subcomponents is provided in Section 3.3.1.1, while Sections 3.3.1.2 and 3.3.1.3 present the materials and environments for the specified subcomponents. The aging effects requiring management and the proposed activities required to manage these effects are discussed in Sections 3.3.1.4 and 3.3.1.5, respectively.

3.3.1.1 Description of MPC MPC Enclosure Vessel The MPC enclosure vessel is a welded cylindrical structure with flat ends that provides confinement of the spent nuclear fuel during storage operations. The confinement boundary, comprised of a baseplate, shell, lid, port covers, and a closure ring, is constructed entirely of stainless steel. The MPC lid is a circular plate edge-welded to the MPC shell. Access to the MPC cavity for the purposes of moisture/air removal and subsequent backfilling with a specified amount of inert gas (helium) is achieved via two penetrations (i.e., vent and drain ports) in the MPC lid.

Circular cover plates are seal welded over the vent and drain ports, completing the primary closure system. A circular closure ring is welded to the MPC shell and lid, providing a redundant closure system at the top end of the MPC.

Lifting lugs attached to the inside surface of the enclosure vessel serve to permit lifting and placement of the empty MPC into the overpack. The lifting lugs also serve to axially locate the lid prior to welding. These internal lifting lugs are not used to handle a loaded MPC. Since the MPC lid is installed prior to any handling of the loaded MPC, there is no access to the lifting lugs once the MPC is loaded. The MPC lid is sufficiently rigid to permit the entire MPC loaded with spent nuclear fuel to be lifted via threaded holes in the top of the lid.

MPC Fuel Basket Within each MPC enclosure vessel is a honeycombed fuel basket responsible for maintaining the spent nuclear fuel in a subcritical condition. Though the number of fuel storage cells will vary depending on the type of fuel to be stored, all fuel baskets are formed from an array of stainless steel plates welded to each other such that the final assembly resembles a multi-flanged, closed-section beam. The location of neutron absorber panels against the walls of the fuel storage cells is fixed via enveloping stainless steel sheathings welded to the basket panels. In addition, flux traps physically separate adjacent fuel storage cells in the MPC-24 fuel baskets.

The fuel basket is positioned and supported within the enclosure vessel by basket shims located in the space between the inside of the shell and the basket. Thin aluminum heat conduction elements are optionally installed between the fuel basket and the support structure and MPC shell to ensure conformal contact. Though all MPC models have identical overall dimensions (e.g., MPC cavity height and fuel basket height), the fuel assemblies stored within may be shorter than the design basis length. As such, upper and lower fuel spacers, as appropriate, are utilized to maintain the axial position of the fuel assembly within the MPC basket.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 28 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-7 3.3.1.2 MPC Materials With the exception of the neutron absorbers which are constructed of either BoralTM or Metamic, and somethe aluminum subcomponents contained in a helium environment, heat conduction elements (only utilized in some MPCs) all other MPC subcomponents in the scope of the license renewal are constructed of stainless steel.

Additional material details for the MPC subcomponents are provided in Table 3.3-1 and 3.3-2.

3.3.1.3 MPC Environments Because the MPC and the HI-STAR 100 overpack cavities are both sealed, dried, and backfilled with helium prior to entering storage, both the internal and external MPC subcomponents are maintained in a very low moisture, helium environment. The temperature ranges from the highest value at the maximum canister head load to the minimum ambient air temperature as the heat load reduces over time. MPC subcomponents are also exposed to significant gamma and neutron radiation.

3.3.1.4 Aging Effects Requiring Management (MPC)

Based on the aging management review of the MPC materials and the environments experienced during long-term storage, the aging effects requiring management are limited to the loss of material properties of the neutron absorber due to radiation.

3.3.1.5 Aging Management Activities (MPC)

Based on the aging management review of the MPC during long-term storage, it has been determined that a time-limited aging analysis (TLAA) for the effects of radiation on the material properties of the neutron absorber. This aging management activity is discussed in Section 3.4.

3.3.2 Aging Management Review Results - HI-STAR 100 Overpack Table 3.3-3 summarizes the results of the aging management review for the HI-STAR 100 overpack subcomponents previously determined to be in the scope of the license renewal.

Additional description of the Overpack subcomponents is provided in Section 3.3.2.1, while Sections 3.3.2.2 and 3.3.2.3 present the materials and environments for the specified subcomponents. The aging effects requiring management and the proposed activities required to manage these effects are discussed in Sections 3.3.2.4 and 3.3.2.5, respectively.

3.3.2.1 Description of Overpack The HI-STAR 100 overpack is a heavy-walled steel cylindrical vessel that provides the helium retention boundary during storage operations. The helium retention boundary is comprised of the overpack inner shell welded to a cylindrical forging at its bottom and a heavy flange with a bolted closure plate at its top. The closure plate is equipped with two concentric grooves for self-energizing seals. Access to the overpacks internal cavity for the purposes of moisture/air removal and subsequent backfilling with a specified amount of inert gas (helium) is achieved via a vent port in the closure plate and a drain port in the bottom forging. Both ports are sealed by threaded port plugs with seals.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 29 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-8 Intermediate shells installed against the outer surface of the inner shell (i.e., helium retention boundary) provide additional structural strength to resist puncture or penetration, as well as provide gamma shielding from the spent fuel contained within. Radial channels welded to the outermost intermediate shell create vertical cavities for retaining and protecting neutron shielding material, as well as acting as fins for improved heat conduction away from the intermediate shell. Additional neutron shielding material cavities are formed by welding enclosure shell panels between the radial channels. To relieve internal pressure that could develop in the neutron shielding cavities, rupture disks are installed atop the outer enclosure shell.

Lifting and rotating the loaded/unloaded overpack between the vertical and horizontal orientations is achieved via a pair of trunnions attached to the heavy top flange. The top pair of trunnions are located 180° apart, while the pocket trunnions, if used, are attached to the lower side of the overpack and located slightly off-center to ensure proper rotation of the overpack.

3.3.2.2 Overpack Materials The majority of the HI-STAR 100 overpack is constructed of carbon steel, with exposed surfaces coated to protect against corrosion. Other materials included in the construction are Holtite for the purposes of neutron shielding and non-ferrous alloys for lifting appurtenances and seals. Additional material details for the HI-STAR 100 overpack subcomponents are provided in Table 3.3-3.

3.3.2.3 Overpack Environments During fuel loading operations, the exterior surface of the overpack is exposed to borated water, while the annulus between the MPC and the inner cavity wall of the overpack is exposed to demineralized water. Prior to entering storage, the annulus water is purged and the overpack cavity is sealed, dried and backfilled with helium creating a very low moisture, helium environment for the inner surface of the overpack helium rentention boundary.

Intermediate overpack components such as the intermediate shells or the inner surfaces of the radial channels and enclosure shell panels are considered to be in embedded environments where potential chemical reactions between adjacent materials are the primary concerns. The outer surfaces of the overpack, including the enclosure shell, radial channels, bottom forging, top flange, and closure plate, are exposed to all weather-related effects, including insolation, wind, rain, snow, ice, and ambient air. Overpack subcomponents are also exposed to gamma and neutron radiation.

3.3.2.4 Aging Effects Requiring Management (Overpack)

Based on the aging management review of the HI-STAR 100 overpack materials and the environments experienced during long-term storage, the aging effects requiring management are loss of material due to corrosion.

3.3.2.5 Aging Management Activities (Overpack)

Based on the aging management review of the HI-STAR 100 overpack during long-term storage, it has been determined that an AMP the exterior surfaces of the overpack is required. This aging management activity is discussed in Section 3.5.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 30 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-9 3.3.3 Aging Management Review Results - Fuel Assembly Table 3.3-4 summarizes the results of the aging management review for the Fuel Assembly subcomponents previously determined to be in the scope of the license renewal.

Additional description of the fuel assembly subcomponents is provided in Section 3.3.3.1, while Sections 3.3.3.2 and 3.3.3.3 present the materials and environments for the specified subcomponents. The aging effects requiring management and the proposed activities required to manage these effects are discussed in Sections 3.3.3.4 and 3.3.3.5, respectively.

3.3.3.1 Description of Fuel Assembly Depending on the MPC model being used, the fuel contained within consists of either 24 PWR fuel assemblies, 32 PWR fuel assemblies, or 68 BWR fuel assemblies. For an MPC containing 24 PWR fuel assemblies, the maximum MPC heat load at the time of loading is 19 kW if the MPC is to be stored in the vertical orientation and 20 kW if the MPC is to be stored in the horizontal orientation. The maximum burnup of the fuel assemblies is 42,100 MWd/MTU with a minimum cooling time of 5 years. For an MPC containing 32 PWR fuel assemblies, the maximum MPC heat load at the time of loading is 18.5 kW if the MPC is to be stored in the vertical orientation and 20 kW if the MPC is to be stored in the horizontal orientation. The maximum burnup of the fuel assemblies is 44,500 MWd/MTU with a minimum cooling time of 8 years. For an MPC containing 68 BWR fuel assemblies, the maximum MPC heat load at the time of loading is 18.5 kW regardless of storage orientation. The maximum burnup of the fuel assemblies is 37,600 MWd/MTU with a minimum cooling time of 5 years. No high burnup fuel is allowed for storage in the HI-STAR 100 system.

The cladding of the fuel assembly provides the primary confinement barrier, while the physical structure of the fuel assembly maintains the axial distribution of the radiological source and its position within the gridwork of the fuel basket. The fuel pellets, hold-down springs and upper end plugs, and control components were excluded from further aging management review because they do not support or impact the intended function of the fuel assemblies during the extended storage period.

3.3.3.2 Fuel Assembly Materials The fuel assembly subcomponents included in the aging management review are made from zircaloy, stainless steel, and/or Inconel. Additional material details for the Fuel Assembly subcomponents are provided in Table 3.3-4.

3.3.3.3 Fuel Assembly Environments Because the MPC is sealed, dried, and backfilled with helium prior to entering storage, the fuel assemblies are maintained in a very low moisture, helium environment. The temperature ranges from the maximum value corresponding to the short term limit for a maximum canister head load to the minimum ambient air temperature as the heat load reduces over time.

3.3.3.4 Aging Effects Requiring Management (Fuel Assembly)

ATTACHMENT 1 TO HOLTEC LETTER 5014914 31 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-10 The fuel assemblies stored in the HI-STAR 100 system are not classified as high-burnup fuel and as such, cladding embrittlement due to irradiation damage or hydride formation is not a concern. A report prepared by Pacific Northwest National Laboratory (PNNL-14390 [3.3.1]), documenting research conducted by EPRI and the US Department of Energy, confirms that similar, non-high-burnup fuel assemblies stored in an inert environment, like the one present inside the MPC, do not exhibit detectable degradation of the cladding or more than negligible release of gaseous fission products during storage. Therefore, no aging effects requiring management are identified for the fuel assemblies.

3.3.3.5 Aging Management Activities (Fuel Assembly)

Because no aging effects requiring management are identified for the fuel assemblies, no aging management activities are required for the renewed license period.

3.3.4 Aging Management Review Results - ISFSI Pad Table 3.3-5 summarizes the results of the aging management review for the ISFSI Pad, previously determined to be in the scope of the license renewal.

Additional description of the ISFSI Pad is provided in Section 3.3.4.1, while Sections 3.3.4.2 and 3.3.4.3 present the materials and environments. The aging effects requiring management and the proposed activities required to manage these effects are discussed in Sections 3.3.4.4 and 3.3.4.5, respectively.

3.3.4.1 Description of ISFSI Pad The ISFSI Pad is a reinforced concrete slab founded on a soil-like subgrade where the loaded HI-STAR 100 overpack will be staged for storage. The ISFSI Pad is designed to limit cask deceleration values at the top of the fuel basket to less than or equal to 60 gs during all design basis drop and tip-over events. To ensure this limit is met, the key parameters that must be taken into consideration and balanced for satisfactory performance are the thickness of the concrete slab, the compressive strength of the concrete, and the equivalent Youngs Modulus of the subgrade. In addition to satisfying this g-load limit requirement, the ISFSI Pad must also possess sufficient flexural and shear stiffness to meet ACI 318.

3.3.4.2 ISFSI Pad Materials The ISFSI Pad is constructed of concrete with embedded ASTM reinforcing bar. Additional material detail for the ISFSI Pad is provided in Table 3.3-5.

3.3.4.3 ISFSI Pad Environments During construction of the ISFSI Pad, the reinforcing bars are passively embedded in the concrete before the concrete sets, thereby protecting the rebar from direct exposure to the ambient environment. The concrete itself is exposed to all weather-related effects, including insolation, wind, rain, snow, ice, and ambient air as discussed in the HI-STAR FSAR Section 2.2.1. The reinforced concrete of the ISFSI Pad is in contact with a soil-like subgrade as discussed in Section 3.3.4.1.

3.3.4.4 Aging Effects Requiring Management (ISFSI Pad)

ATTACHMENT 1 TO HOLTEC LETTER 5014914 32 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-11 This section describes the aging effects/mechanisms that could, if left unmanaged, cause degradation of the ISFSI pad and result in a loss of intended function(s) during the period of extended operation. The potential aging effects/mechanisms that were considered for the ISFSI pad were based on the NRCs draft MAPS report [3.2.1].

The AMR results for the ISFSI pad are listed in Table 3.3-5.

3.3.4.5 Aging Management Activities (ISFSI Pad)

The ISFSI Pad Aging Management Program manages the aging effects for the ISFSI pad.

A description of this aging management program is provided in Appendix C along with the demonstration that the identified aging effects will be effectively managed for the period of extended operation.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 33 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-12 3.4 Time-Limited Aging Analyses (TLAA)

Using the TLAA-identification criteria discussed in Section 3.2.4.1, the CoC, SER, Technical Specifications were reviewed and the following TLAAs were identified for further evaluation and disposition, and are described in Appendix B:

1. Neutron Absorber Depletion 1.2. Fuel Cladding Integrity ATTACHMENT 1 TO HOLTEC LETTER 5014914 34 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-13 3.5 Aging Management Programs (AMP)

Based on the results of the aging management reviews for systems, structures, and components (SSC) previously determined to be within the scope of the license renewal, presented above, the following AMPs are required:

1. Overpack AMP
2. ISFSI Pad AMP The full details of these AMPs are presented in Appendix A.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 35 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.DC 3-14 3.6 References

[3.1.1]

HI-2188307 ECO Review in Support of HI-STAR 100 Renewal Application, Holtec International, latest revision

[3.1.2]

Holtec Letter 5014828, HI-STAR 100 Final Safety Analysis Report Update per 10CFR72.248(c)(6), dated October 20, 2017

[3.2.1]

Draft NUREG-2214, Managing Aging Processes in Storage (MAPS) Report, US NRC, October2017

[3.3.1]

PNNL-14390, Dry Storage Demonstration for High-Burnup Spent Nuclear Fuel - Feasibility Study, August 2003 ATTACHMENT 1 TO HOLTEC LETTER 5014914 36 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-15 Table 3.3-1: Aging Management Review of MPC Enclosure Vessel Subcomponents Subcomponent Primary Function Material Environment1 Aging Effects Requiring Management Aging Mechanism Aging Management Activity Shell Confinement SA-240 TYPE 316/316L Helium None identified None identified None Required Baseplate Confinement SA-240 TYPE 316/316L Helium None identified None identified None Required Lid (one-piece design or top portion of two-piece design) Confinement Alloy X Helium None identified None identified None Required Closure Ring Confinement Alloy X Helium None identified None identified None Required Vent/Drain Port Cover Plate Confinement SA-240 TYPE 316/316L Helium None identified None identified None Required Vent/Drain Shield Block Shielding Alloy X Helium None identified None identified None Required Plugs for Drilled Holes Shielding Alloy X Helium None identified None identified None Required Bottom Portion of Two-Piece Lid (if applicable)

Shielding Alloy X Helium None identified None identified None Required Lift Lug Structural Integrity Alloy X Helium None identified None identified None Required Lift Lug Baseplate Structural Integrity Alloy X Helium None identified None identified None Required Upper Fuel Spacer Column Structural Integrity Alloy X Helium None identified None identified None Required Upper Fuel Spacer Bolt Structural Integrity A193-B8 Helium None identified None identified None Required Upper Fuel Spacer End Plate Structural Integrity Alloy X Helium None identified None identified None Required Lower Fuel Spacer Column Structural Integrity Stainless Steel Helium None identified None identified None Required ATTACHMENT 1 TO HOLTEC LETTER 5014914 37 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-16 Table 3.3-1: Aging Management Review of MPC Enclosure Vessel Subcomponents Subcomponent Primary Function Material Environment1 Aging Effects Requiring Management Aging Mechanism Aging Management Activity Lower Fuel Spacer End Plate Structural Integrity Alloy X Helium None identified None identified None Required Vent Shield Block Spacer Structural Integrity Alloy X Helium None identified None identified None Required Vent/Drain Tube Retrievability Stainless Steel Helium None identified None identified None Required Vent/Drain Port Cap Retrievability Stainless Steel Helium None identified None identified None Required Vent/Drain Cap Seal Washer Retrievability Aluminum Helium None identified None identified None Required Vent/Drain Cap Seal Washer Bolt Retrievability Aluminum Helium None identified None identified None Required Vent and Drain

Tube, Optional Retrievability Stainless Steel Helium None identified None identified None Required Threaded
Disc, Plug Adjustment Retrievability Stainless Steel Helium None identified None identified None Required Vent and Drain Plug Retrievability Aluminum Helium None identified None identified None Required Thread Shield Cap Retrievability Aluminum Helium None identified None identified None Required Retaining Ring Retrievability Stainless Steel Helium None identified None identified None Required Vent/Drain Tube Operations SA-479 TYPE 304 Helium None identified None identified None Required Vent/Drain Port Cap Operations Stainless Steel Helium None identified None identified None Required Vent/Drain Cap Seal Washer Operations Aluminum Helium None identified None identified None Required Vent/Drain Cap Seal Washer Bolt Operations Aluminum Helium None identified None identified None Required Reducer Operations Alloy X Helium None identified None identified None Required ATTACHMENT 1 TO HOLTEC LETTER 5014914 38 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-17 Table 3.3-1: Aging Management Review of MPC Enclosure Vessel Subcomponents Subcomponent Primary Function Material Environment1 Aging Effects Requiring Management Aging Mechanism Aging Management Activity Drain Line Operations Alloy X Helium None identified None identified None Required Drain Line Guide Tube Operations Stainless Steel Helium None identified None identified None Required Support Plate (for Drain Line)

Operations Alloy X Helium None identified None identified None Required Notes:

1) Unlike ventilated casks, the HI-STAR 100 is sealed and filled with helium, so both the inner and outer surfaces of the MPC are contained within an inert helium environment.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 39 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-18 Table 3.3-2: Aging Management Review of MPC Fuel Basket Subcomponents Subcomponent Primary Function Material Environment1 Aging Effects Requiring Management Aging Mechanism Aging Management Activity Basket Cell Plate Criticality Control Alloy X Helium None identified None identified None Required Neutron Absorber Criticality Control Metamic or BoralTM Helium Loss of material properties Radiation TLAA See Appendix B Sheathing Structural Integrity Alloy X Helium None identified None identified None Required Shim Structural Integrity SA-479 TYPE 316/316L Helium None identified None identified None Required Basket Support (Angled Plate)

Structural Integrity SA-240 TYPE 316/316L Helium None identified None identified None Required Basket Support (Flat Plate)

Structural Integrity SA-240 TYPE 316/316L Helium None identified None identified None Required Optional Aluminum Heat Conduction Elements Heat Transfer Aluminum; Alloy 1100 Helium None identified None identified None Required Notes:

1) Unlike ventilated casks, the HI-STAR 100 is sealed and filled with helium, so both the inner and outer surfaces of the MPC are contained within an inert helium environment.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 40 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-19 Table 3.3-3: Aging Management Review of HI-STAR 100 Overpack Subcomponents Subcomponent Primary Function Material Environment1,2 Aging Effects Requiring Management Aging Mechanism3 Aging Management Activity Inner Shell Helium Retention SA-203 Gr. E or SA-350 LF3 Helium None identified None identified None Required Bottom Plate Helium Retention SA-350 LF3 Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program Galvanic Corrosion Pitting and Crevice Corrosion Embedded (in concrete)

Embedded (in concrete)Loss of Material General Corrosion Pitting and Crevice Corrosion Microbiologically Induced Corrosion Top Flange Helium Retention SA-350 LF3 Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program Galvanic Corrosion Pitting and Crevice Corrosion Closure Plate Helium Retention SA-350 LF3 Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program Galvanic Corrosion Pitting and Crevice Corrosion Closure Plate Bolt Helium Retention SB-637 N07718 Air-Outdoor None identified None identified None required Port Plug Helium Retention SA-193 B8 Embedded None identified None identified None Required ATTACHMENT 1 TO HOLTEC LETTER 5014914 41 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-20 Table 3.3-3: Aging Management Review of HI-STAR 100 Overpack Subcomponents Subcomponent Primary Function Material Environment1,2 Aging Effects Requiring Management Aging Mechanism3 Aging Management Activity Port Plug Seal Helium Retention Alloy X750 Air-Outdoor None identified None identified None Required Closure Plate Seal Helium Retention Alloy X750 Air-Outdoor None identified None identified None Required Port Cover Seal Helium Retention Alloy X750 Air-Outdoor None identified None identified None Required Intermediate Shell Shielding SA-516 Gr. 70 Embedded None identified None identified None Required Neutron Shield Shielding Holtite-A Embedded (in steel)

Radiation Embrittlement Cracking Overpack Aging Management Program Shielding Effectiveness Test Thermal Aging Loss of fracture toughness and loss of ductility Overpack Aging Management Program Shielding Effectiveness Test Boron Depletion Loss of shielding Overpack Aging Management Program Shielding Effectiveness Test Plugs for Drilled Holes Shielding SA-193 B7 Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program Pitting and Crevice Corrosion Removable Shear Ring Shielding SA-203 Gr.

E Carbon Steel Air-OutdoorEmbedded Loss of MaterialNone identified General CorrosionNone identified Overpack Aging Management ATTACHMENT 1 TO HOLTEC LETTER 5014914 42 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-21 Table 3.3-3: Aging Management Review of HI-STAR 100 Overpack Subcomponents Subcomponent Primary Function Material Environment1,2 Aging Effects Requiring Management Aging Mechanism3 Aging Management Activity Pitting and Crevice Corrosion ProgramNone Required Radial Channel Heat Transfer SA-515 Gr. 70 Embedded / Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program (for non-embedded portions)

Pitting and Crevice Corrosion Lifting Trunnion Structural Integrity SB-637 N07718 Air-Outdoor None identified None identified None required Pocket Trunnion Plug Plate Shielding SA240-304 Air-Outdoor None identified None identified None required Pocket Trunnion Rotation Pivot and Shielding SA705-630, 17-4 pH OR SA564-630, 17-4 pH Air-Outdoor None identified None identified None required Relief Device Structural Integrity CommercialStainless teel Air-Outdoor Loss of Material General Corrosion Routine Maintenance Relief Device Plate Structural Integrity SA-516 Gr. 70 or A569 Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program Galvanic Corrosion Pitting and Crevice Corrosion Removable Shear Ring Bolt Structural Integrity SA-193 B7 Air-OutdoorEmbedded Loss of MaterialNone identified General CorrosionNone identified Overpack Aging Management ProgramNone Required Pitting and Crevice Corrosion Thermal Expansion Foam Structural Integrity Silicone Foam Embedded None identified None identified None Required ATTACHMENT 1 TO HOLTEC LETTER 5014914 43 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-22 Table 3.3-3: Aging Management Review of HI-STAR 100 Overpack Subcomponents Subcomponent Primary Function Material Environment1,2 Aging Effects Requiring Management Aging Mechanism3 Aging Management Activity Closure Bolt Washer Structural Integrity A564, 17-7 PH Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program Pitting and Crevice Corrosion Enclosure Shell Panel Structural Integrity SA-515 Gr. 70 Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program Pitting and Crevice Corrosion Enclosure Shell Return Structural Integrity SA-515 Gr. 70 Air-OutdoorEmbedded Loss of MaterialNone identified General CorrosionNone identified Overpack Aging Management ProgramNone Required Pitting and Crevice Corrosion Port Cover Structural Integrity SA-203 Gr. E or SA-350 LF3 Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program Galvanic Corrosion Pitting and Crevice Corrosion Port Cover Bolt Structural Integrity SA-193 B7 Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program Pitting and Crevice Corrosion Trunnion End Cap Operations SA-516 Gr. 70 or SA-515 Gr. 70 Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program Trunnion End Cap Bolt Operations SA-193 B7 Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program ATTACHMENT 1 TO HOLTEC LETTER 5014914 44 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-23 Table 3.3-3: Aging Management Review of HI-STAR 100 Overpack Subcomponents Subcomponent Primary Function Material Environment1,2 Aging Effects Requiring Management Aging Mechanism3 Aging Management Activity Lifting Trunnion Locking Pad Operations SA-516 Gr. 70 Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program Trunnion Locking Pad Bolt Operations SA-193 B7 Air-Outdoor Loss of Material General Corrosion Overpack Aging Management Program Nameplate Operations Stainless Steel Air-Outdoor None identified None identified None Required Notes:

1) Unlike ventilated casks, the HI-STAR 100 is sealed and filled with helium, so the inner surfaces of the overpack are contained within an inert helium environment.
2) The term embedded refers to the fact that the individual component is mechanically sealed and is not exposed to any environment.
3) The term general corrosion refers to loss of material due to corrosion, proceeding at approximately the same rate over a metal surface, also referred to as uniform corrosion.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 45 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-24 Table 3.3-4: Aging Management Review of Fuel Assembly Subcomponents Subcomponent Primary Function Material Environment Aging Effects Requiring Management Aging Mechanism Aging Management Activity Fuel Pellets N/A N/A N/A N/A N/A None Required Fuel Cladding Criticality

Control, Radiation Shielding, Confinement Structural Integrity Zircaloy Helium None identified None identified None Required Spacer Grid Assemblies Criticality
Control, Structural Integrity Zircaloy Helium None identified None identified None Required Upper End Fitting Structural Integrity Stainless Steel Inconel Helium None identified None identified None Required Lower End Fitting Structural Integrity Stainless Steel Inconel Helium None identified None identified None Required Guide Tubes Structural Integrity Zircaloy

/

Stainless Steel Helium None identified None identified None Required Hold-Down Spring Upper End Plugs N/A N/A N/A N/A N/A None Required Control Components N/A N/A N/A N/A N/A None Required ATTACHMENT 1 TO HOLTEC LETTER 5014914 46 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-25 Table 3.3-5: Aging Management Review of ISFSI Pad Subcomponent Primary Function Material Environment Aging Effects Requiring Management Aging Mechanism Aging Management Activity ISFSI Pad Structural Integrity Concrete (Reinforced)

Air-Outdoor Change in Material Properties Leaching of Ca(OH)2 (1,2,3)

ISFSI Pad Aging Management Program Aggressive chemical attack (1,2)

ISFSI Pad Aging Management Program Cracking Freeze-thaw ISFSI Pad Aging Management Program Aggressive chemical attack ISFSI Pad Aging Management Program Differential settlement ISFSI Pad Aging Management Program Reaction with Aggregates ISFSI Pad Aging Management Program Loss of material properties (spalling, scaling)

Aggressive chemical attack ISFSI Pad Aging Management Program Freeze and thaw ISFSI Pad Aging Management Program Salt scaling ISFSI Pad Aging Management Program ATTACHMENT 1 TO HOLTEC LETTER 5014914 47 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-26 Table 3.3-5: Aging Management Review of ISFSI Pad Subcomponent Primary Function Material Environment Aging Effects Requiring Management Aging Mechanism Aging Management Activity Embedded (in soil)

Loss of Material Freeze-thaw ISFSI Pad Aging Management Program Aggressive chemical attack ISFSI Pad Aging Management Program Salt scaling ISFSI Pad Aging Management Program Microbiological degradation ISFSI Pad Aging Management Program Corrosion of reinforced steel ISFSI Pad Aging Management Program Cracking Aggressive chemical attack ISFSI Pad Aging Management Program Differential settlement ISFSI Pad Aging Management Program Freeze and thaw ISFSI Pad Aging Management Program Reaction to aggregates ISFSI Pad Aging Management Program Corrosion of reinforced steel ISFSI Pad Aging Management Program ATTACHMENT 1 TO HOLTEC LETTER 5014914 48 of 99

HOLTEC INTERNATIONAL COPYRIGHT MATERIAL HI-2188306 Proposed Rev. 1.D 3-27 Table 3.3-5: Aging Management Review of ISFSI Pad Subcomponent Primary Function Material Environment Aging Effects Requiring Management Aging Mechanism Aging Management Activity Change in Material Properties Cracking Leaching of Ca(OH)2 (1,2,3)

ISFSI Pad Aging Management Program Aggressive chemical attack (1,2)

ISFSI Pad Aging Management Program Microbiological degradation (1,2,3)

ISFSI Pad Aging Management Program Corrosion of reinforced steel (1,4)

ISFSI Pad Aging Management Program Reaction with Aggregates (1)

ISFSI Pad Aging Management Program Note-The changes in material properties for every aging mechanism are indicated in the table above. Change in material properties includes -

(1) Loss of strength (2) Reduction of concrete pH (3) Increase in porosity and permeability.

(4) Loss of concrete steel bond ATTACHMENT 1 TO HOLTEC LETTER 5014914 49 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-3188306 Proposed Rev. 1.A 4-1

CHAPTER 4: AGING MANAGEMENT TOLLGATES 4.0 Introduction NEI 14-03 (Ref [1.0.2]) introduced the concept of tollgates to be included as part of an operations-based aging management program. The tollgate concept provides a structured way for licensees to pause and formally assess aggregated feedback at specific points in time during the period of extended storage.

Tollgates are established as requirements in the generic CoC renewed application, and implemented by ISFSI generic licensees to evaluate aging management feedback and perform a safety assessment that confirms the safe storage of spent nuclear fuel. The impact of the aggregate feedback will be assessed by the site as it pertains to components at the sites ISFSI and actions taken as necessary, such as:

Adjustment of aging-related degradation monitoring and inspection programs in AMPs described in Appendix A (e.g. scope, frequency)

Modification of TLAAs described in Appendix B Performance of mitigation activities Each tollgate assessment will address the following elements as applicable:

Summary of research findings, operating experience, monitoring data, and inspection results made available since last assessment Aggregate impact of findings, including any trends Consistency of data with the assumptions and inputs in the TLAAs Effectiveness of AMPs Corrective actions, including any changes to AMPs Summary and conclusions Sites will have access to the ISFSI Aging Management INPO Database to facilitate the aggregation and dissemination of aging-related information for the completion of these tollgate assessments. Generic tollgates are shown in Table 4-1. Note that the implementation of these tollgates does not infer that generic licensees will wait until one of these designated times to evaluate information. Sites will continue to follow existing processes for addressing emergent issues, including the use of the corrective action program on site. These tollgates are specific times where an aggregate of information will be evaluated as a whole.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 50 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-3188306 Proposed Rev. 1.A 4-2

Table 4-1: Tollgate Assessments for General Licensees Tollgate Year Assessment 1

Year of first canister loading +

25 years Evaluate information from the following sources (as available) and perform a written assessment of the aggregate impact of the information, including but not limited to trends, corrective actions required, and the effectiveness of the AMPs with which they are associated:

Results, if any, of research and development programs focused specifically on aging-related degradation mechanisms identified as potentially affecting the storage system and ISFSI site. One example of such research and development would be EPRI Chloride-Induced Stress Corrosion Cracking (CISCC) research.

Relevant results of other domestic and international research, which may include non-nuclear research Relevant domestic and international operating experience, which may include non-nuclear operating experience Relevant results of domestic and international ISFSI and dry storage system performance monitoring 2

Maximum interval of 5 years since last tollgate Evaluate additional information gained from the sources listed in Tollgate 1 along with any new relevant sources and perform a written assessment of the aggregate impact of the information. This evaluation should be informed by the results of Tollgate 1. The aging effects and mechanisms evaluated at this tollgate and the time at which it is conducted may be adjusted based on the results of the Tollgate 1 assessment.

3 Maximum interval of 5 years since last tollgate Same as Tollgate 2 as informed by the results of Tollgates 1 and 2 4

Maximum interval of 5 years since last tollgate Same as Tollgate 2 as informed by the results of Tollgates 1, 2, and 3 5

Maximum interval of 5 years since last tollgate Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, and 4 6

Maximum interval of 5 years since last tollgate Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, 4, and 5

7 Maximum interval of 5 years since last tollgate Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, 4, 5, and 6 8

Maximum interval of 5 years since last tollgate Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, 4, 5, 6, and 7 ATTACHMENT 1 TO HOLTEC LETTER 5014914 51 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.C A-1

APPENDIX A: HI-STAR 100 AMPs A.0 Introduction Section 3.5 identifies the following needed AMPs:

1. Overpack AMP
2. ISFSI Pad AMP This appendix contains the 10 elements of the AMPs, following the guidance of NUREG-1927 Revision
1.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 52 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.C A-2

Overpack Exterior AMP Element Description

1. Scope of Program The program covers the subcomponents of the HI-STAR 100 Overpack identified in Table 3.3-3 which require the HI-STAR 100 Overpack AMP, to operate into the extended storage period.
2. Preventative Actions This AMP uses condition monitoring to manage aging effects. The design of the system is intended to minimize aging effects on the system, but this AMP focuses on condition monitoring and detecting any evidence of degradation. No new preventative actions are included in this AMP.
3. Parameters Monitored /

Inspected The condition of the exterior of each in-service cask is inspected visually to ensure the intended functions of the cask exterior are not compromised. Visual inspections will look for:

Visual evidence of discontinuities, imperfections, and rust staining indicative of corrosion, SCC, and wear Visual evidence of loose or missing bolts, physical displacement, and other conditions indicative of loss of preload Visual evidence of coating degradation (e.g., blisters, cracking, flacking, delamination) indicative of corrosion of the base metal

4. Detection of Aging Effects Readily Accessible Surfaces Annual Examination A visual inspection of all normally accessible portions of the exterior surface of the overpack provides a means to detect degradation of these components due to a potential loss of material and confirm that the intended functions are not compromised. This visual inspection shall be performed on all HI-STAR 100 casks annually. This inspection was required for the initial license period, per FSAR Table 9.2.1, so it is recommended that users follow their existing inspection procedures for these annual inspections.

5 Year Code Inspection Once every 5 years, visual inspections are performed in accordance with ASME Code Section XI, Article IWA-2213, for VT-3 examinations, and cover all normally accessible surfaces on all casks. This visual inspection is conducted by a qualified individual.

Shielding Effectiveness A shielding effectiveness test shall be performed every five years on each overpack. Calibrated neutron and gamma dose meters shall be used to measure the actual neutron and gamma dose rates at the surface of the HI-STAR overpack. Measurements will be taken at three cross-sectional planes and at four points along each planes circumference. Additionally, four measurements shall be taken at the top of the overpack closure plate. The average results from each sectional plane shall be compared to the design basis limits for surface dose rates established in the HI-STAR 100 FSAR Chapter 5. This test was required for the initial license period, per FSAR Table 9.1.2 (although the ATTACHMENT 1 TO HOLTEC LETTER 5014914 53 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.C A-3

frequency may have been different), so it is recommended that users follow their existing test procedures.

Data Collection Data from the visual examinations and shielding effectiveness test shall be documented on a checklist or inspection form. The results of the inspection shall be documented, including descriptions of observed aging effects and supporting sketches, photographs, or video. Corrective actions resulting from each AMP inspection shall also be documented.

Timing Annual external examinations and shielding effectiveness tests are continued from the initial period of operation.

The first 5 year code inspection should be performed when the cask enters its period of extended operation. If the cask is already in its period of extended operation (due to timely renewal) or within 365 days of entering its period of extended operation when the renewed license is issued, the site has 365 days to complete the first 5 year code inspection from the issuance of the renewed license.

5. Monitoring and Trending The inspections and tests described for external subcomponents of the HI-STAR 100 are performed periodically in order to identify areas of degradation.

The visual inspection results will be evaluated by a qualified individual, and areas of degradation not meeting established criteria will be entered into the site Corrective Action Program (CAP) for resolution or more detailed evaluation.

The shielding test results shall be compared to the acceptance criteria (described below), and results not meeting these criteria will be entered into the site CAP for resolution or more detailed evaluation. The results from both the visual inspection and shielding tests will be compared against previous inspections in order to monitor and trend the progression of the aging effects over time.

6. Acceptance Criteria External Visual Inspection The acceptance criteria for the visual inspections are:

No detectable loss of material from the base metal, including uniform wall thinning, localized corrosion pits, and crevice corrosion No red-orange-colored corrosion products on the base metal or coatings No coating defects (e.g., blisters, cracking, flaking, delamination)

No indications of loose bolts or hardware, displaced parts No evidence of corrosion such as rust on the ISFSI pad concrete in the area adjacent to the overpack If evidence of corrosion, wear, or coating degradation is identified, then the severity of the degradation must be determined using approved site-specific procedures. These may include additional visual, surface, or volumetric non destructive examination methods to determine the loss of material.

Shielding Effectiveness Test ATTACHMENT 1 TO HOLTEC LETTER 5014914 54 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.C A-4

The dose rate measurements described above shall be compared to the design basis limits for surface dose rates from the HI-STAR 100 FSAR Chapter 5.

The test results are considered acceptable if the actual dose readings are lower or equal to the acceptance criteria in the Technical Specifications. If dose rates are higher than the Technical Specification limits, the required actions of the Technical Specifications shall be completed.

7. Corrective Actions The corrective actions performed based on any detected aging effects are in accordance with the sites Quality Assurance (QA) program. The QA Program ensures that corrective actions are completed within the sites Corrective Action Program (CAP).

As applicable, the CAP program will perform cause evaluations, address the extent of condition, determine any necessary actions to prevent recurrence, identify any changes to the existing AMP, and determine if the condition is reportable.

The CAP program corrective actions will also identify the actions needing to be taken for increased scope or frequency of inspections, as necessary, based on any detected aging effects. One potential corrective action, if significant exterior corrosion is found in the area, could be to perform additional inspections of inaccessible surfaces, such as the bottom of the cask.

8. Confirmation Process The confirmation process will be commensurate with the site QA Program.

The QA program ensures that inspections, evaluations, and corrective actions are completed in accordance with the site CAP.

9. Administrative Controls The site QA program and implementing procedures for this AMP will address instrument calibration and maintenance, inspector requirements, record retention requirements, and document control.

This AMP will be updated periodically, as necessary, based on the toll gate assessments described in Chapter 4 of this application. Inspection results will be documented and made available for NRC inspectors to view upon request.

10. Operating Experience Previous Operating Experience The sites have utilized the same HI-STAR 100 casks since they were initially loaded. Both the periodic visual inspections and periodic shielding effectiveness tests have not shown any aging related degradation of the system.

Future Operating Experience As the inspections are performed, sites will upload information into the INPO AMID database to be shared with other users.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 55 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.C A-5

ISFSI Pad AMP Element Description

1. Scope of Program The program covers the subcomponents of the ISFSI Pad identified in Table 3.3.5 which require the ISFSI Pad AMP, to operate into the extended storage period. The scope covers inspections of the above grade areas of the pad which are readily accessible and monitoring for the below grade portions exposed to foundation soil, backfill, or groundwater per the requirements described in ACI 349.3R-02/
2. Preventative Actions This AMP uses condition monitoring to manage aging effects. The design of the ISFSI Pad is intended to minimize aging effects on the system, but this AMP focuses on condition monitoring. No new preventative actions are included in this AMP.
3. Parameters Monitored /

Inspected The ISFSI Pad above -grade exposed surfaces are visually examined for cracking, loss of material (spalling, scaling), loss of bond, and increased porosity/permeability. The below-grade portions of the pad exposed to soil environments are monitored in accordance with ACI 349.3R-02.

Degradation could affect the ability of the concrete pad to provide support to the casks over the period of extended storage. The pad itself does not have any safety function, but may impact the storage of the casks.

4. Detection of Aging Effects The ISFSI Pad AMP is a visual inspection of all readily accessible surfaces in order to detect any aging effects. The visual survey in accordance with ACI-349.3R-02, should identify the source of any staining or corrosion-related activity and the degree of damage. This visual inspection identifies the current condition of the pad and can identify the extent and cause of any aging effect noted. This visual inspection is conducted every 5 years by a qualified individual. Visual inspections of below grade areas are performed on an opportunistic basis, only when excavations in the area occur.

Timing The first ISFSI pad inspection (of above-grade areas) should be performed when the first cask on the pad enters its period of extended operation. If the cask is already in its period of extended operation (due to timely renewal) or within 365 days of entering its period of extended operation when the renewed license is issued, the site has 365 days to complete the first 5 year code inspection from the issuance of the renewed license.

Technical evaluation of below grade materials based on activities described in ACI 349.3R-02, such as ground water chemistry or opportunistic visual inspections should be performed and documented at periodic intervals of 10 years.

5. Monitoring and Trending The inspection described for the ISFSI pad is performed periodically in order to identify areas of degradation. The results will be evaluated by a ATTACHMENT 1 TO HOLTEC LETTER 5014914 56 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.C A-6

qualified individual, and areas of degradation not meeting established criteria will be entered into the site CAP for resolution or more detailed evaluation. The results will be compared against previous inspections in order to monitor and trend the progression of the aging effects over time.

6. Acceptance Criteria American Concrete Institute Standard 349.3R-02 includes quantitative three-tier acceptance criteria for visual inspections of concrete surfaces, namely (1) acceptance without further evaluation, (2) acceptance after review, (3) acceptance requiring further evaluation. Acceptable signifies that a component is free of significant deficiencies or degradation that could lead to the loss of structural integrity. Acceptable after review signifies that a component contains deficiencies or degradation but will remain able to perform its design basis function until the next inspection or repair. Acceptance requiring further evaluation signifies that a component contains deficiencies or degradation that could prevent (or could prevent prior to the next inspection) the ability to perform their design basis function. Degradations or conditions meeting the ACI349.3R-02 Tier 2 and 3 criteria will be entered into the sites CAP for evaluation and resolution. Should the site determine there is a need to deviate from the ACI394.3R-02 acceptance criteria; a technical justification will be fully documented.
7. Corrective Actions The corrective actions performed based on any detected aging effects are in accordance with the sites Quality Assurance (QA) program. The QA Program ensures that corrective actions are completed within the sites Corrective Action Program (CAP).

As applicable, the CAP program will perform cause evaluations, address the extent of condition, determine any necessary actions to prevent recurrence, identify any changes to the existing AMP, and determine if the condition is reportable.

The CAP program corrective actions will also identify the actions needing to be taken for increased scope or frequency of inspections, as necessary, based on any detected aging effects.

8. Confirmation Process The confirmation process will be commensurate with the site QA Program. The QA program ensures that inspections, evaluations, and corrective actions are completed in accordance with the site CAP.
9. Administrative Controls The site QA program and implementing procedures for this AMP will address instrument calibration and maintenance, inspector requirements (commensurate with ACI 349.3R-02), record retention requirements, and document control.

This AMP will be updated periodically, as necessary, based on the toll gate assessments described in Chapter 4 of this application. Inspection ATTACHMENT 1 TO HOLTEC LETTER 5014914 57 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.C A-7

results will be documented and made available for NRC inspectors to view upon request.

10. Operating Experience Previous Operating Experience A survey of Holtec users indicates only very minor signs of degradation of the ISFSI pad, such as minor local spalling. Based on this prior experience, the AMP is sufficient to detect aging effects.

Future Operating Experience As the ISFSI Pad inspections are performed, sites will upload information into the INPO AMID database to be shared with other users.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 58 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.B B-1

APPENDIX B: HI-STAR 100 TLAAs B.0 Introduction This appendix contains a summary of the Time Limited Aging Analyses (TLAAs) performed in support of the HI-STAR 100 license renewal, which meet the definition in 10CFR72.3.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 59 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.B B-2

B.1 Identification of HI-STAR 100 TLAAs Using the TLAA-identification criteria discussed in Section 3.2.4.1 of this report, the CoC, SER, Technical Specifications were reviewed and the following TLAAs were identified for further evaluation and disposition:

1. Neutron Absorber Depletion 1.2. Fuel Cladding Integrity ATTACHMENT 1 TO HOLTEC LETTER 5014914 60 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.B B-3

B.2 Neutron Absorber Depletion Section 6.3.2 of the HI-STAR 100 FSAR describes the boron depletion of the fixed neutron absorber within the MPC. The original analysis demonstrated that the boron depletion of the neutron absorbing material is negligible over a 50 year duration. [PROPRIETARY INFORMATION WITHHELD PER 10CFR2.390]. The same analysis was re-performed in support of this license renewal request, as documented in Ref. [B.2.1].

The analysis concludes that the total depletion of B-10 in Boral over a 500 year period is negligible (less than 1 ppm of total B-10 atoms depleted). Therefore, the TLAA for neutron absorber depletion shows that the neutron absorber will perform its intended function well into the extended storage period and that no aging management program is needed to manage the neutron absorber aging.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 61 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.B B-4

B.3 Fuel Cladding Integrity The HI-STAR 100 System FSAR (Section 4.3) provides an analysis of the integrity of the fuel to be stored, which includes a time-based assumption, and could be considered a TLAA. However, subsequently, the NRC issued ISG-11, Revision 3 which provides temperature limits for fuel. If fuel is maintained under those limits, there is no concern with time-based degradation. High burnup fuel is not allowed for storage in the HI-STAR 100 and under all amendments the fuel cladding temperature was maintained below ISG-11 limits. Therefore, the analysis is not re-performed for the extended period of operation, since the ISG provides technical information which supports storage of fuel in the HI-STAR 100 System.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 62 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.B B-5

B.3 References

[B.2.1]

HI-951322R24, HI-STAR 100 Shielding Design and Analysis for Transport and Storage, Appendix 3 ATTACHMENT 1 TO HOLTEC LETTER 5014914 63 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.A C-1

APPENDIX C: SYSTEM INSPECTIONS C.0 Introduction There are two types of initial storage system inspections related to the HI-STAR 100 CoC renewal applications and initial AMP implementation, respectively. The first type, known as a pre-application inspection is intended to gather information to inform the development of the renewal application in general, and AMPs for specific SSCs in particular. The second, known as a baseline inspection, is essentially the first AMP inspection of the SSC, which is performed at a particular ISFSI at approximately the time when the storage system enters the period of extended storage.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 64 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.A C-2

C.1 Pre-application Inspections Although a pre-application inspection is not a regulatory requirement, the HI-STAR 100 System has undergone a number of pre-application inspections which have informed the AMPs included in this application.

C.1.1 Overpack External The HI-STAR 100 system FSAR already required an annual visual external examination, in Table 9.2.1.

This inspection is continued as one part of the overpack AMP. These previous inspections lessons learned have been incorporated into the acceptance criteria in the AMP in this application.

C.1.2 ISFSI Pad ISFSI Pads in use at existing sites have been examined over the course of their use. Lessons learned from these previous inspections have been incorporated into the acceptance criteria in the AMP in this application.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 65 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.A C-3

C.2 Baseline Inspections Baseline inspections are the first AMP inspections conducted at an ISFSI site at the approximate time the ISFSI enters the period of extended storage (i.e., 20 years after the first HI-STAR 100 system was placed in service). The baseline inspection for the ISFSI meets the criteria defined in the AMPs in Appendix A.

Note that sites that have entered the period of extended operation prior to issuance of the renewed license or are near the period of extended operation when the renewal is issued have a grace period from the issuance of the renewed license. Table C.2-1 describes the schedule for baseline and subsequent inspections. This schedule applies to both the Overpack External Code Inspection and the ISFSI Pad Inspection.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 66 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.A C-4

Table C.2-1 Aging Management Program Schedule Date of First Canister Loading Period of Extended Storage Date Baseline Inspection Date Subsequent Inspection Date Date x, 1999 Date x, 2019 By Date of Renewed License Approval +

365 Days 5 years after the baseline inspection +/- 1 year Date x, 2000 Date x, 2020 By Date of Renewed License Approval +

365 Days 5 years after the baseline inspection +/- 1 year Date x, 2001 Date x, 2021 By Date of Renewed License Approval +

365 Days 5 years after the baseline inspection +/- 1 year Date x, 2002 and later Date x, 2022 and later Inspection prior to Period of Extended Storage Date 5 years after the baseline inspection +/- 1 year ATTACHMENT 1 TO HOLTEC LETTER 5014914 67 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.D D-1

APPENDIX D: AGING MANAGEMENT FSAR CHANGES ATTACHMENT 1 TO HOLTEC LETTER 5014914 68 of 99

HI-STAR 100 FSAR Rev. 4 REPORT HI-2012610 1.2-16 Table 1.2.2 KEY PARAMETERS FOR HI-STAR 100 MULTI-PURPOSE CANISTERS PWR BWR Pre-disposal service life, years 560 560 Design temperature, oF (°C)

Max Min 752 oF (400°C)

-40 °F (-40 oC) 752 oF (400°C)

-40 °F (-40 oC)

Design internal pressure, psig (kpad)

Normal conditions Off-normal conditions Accident Conditions 100 (690) 100 (690) 200 (1379) 100 (690) 100 (690) 200 (1379)

Total heat load, max. (kW)

Vertical Orientation Horizontal Orientation MPC-24 19 kW 20 kW MPC-32 18.5 kW 20 kW 18.5 (MPC-68) 18.5 (MPC-68)

Maximum permissible peak fuel cladding temperature:

Normal Short Term & Accident See Chapter 4 See Chapter 4 MPC internal environment Helium fill at 70°F (21°C),

psig (kpad)

Vertical Orientation Horizontal Orientation

< 22.2 (153)

< 44.8 (309)

< 22.2 (153)

< 44.8 (309)

MPC external environment/overpack internal pressure Helium fill initial pressure, psig (kpad) at STP 10 (69) 10 (69)

Maximum permissible reactivity including all uncertainties and biases

<0.95

<0.95 Fixed Neutron Absorber 10B Areal Density (g/cm2)

Boral Metamic MPC-24 0.0267 0.0223 MPC-32 0.0372 0.0310 MPC-68 0.0372 0.0310 MPC-68F (Note 1) 0.01 NA End closure(s)

Welded Welded ATTACHMENT 1 TO HOLTEC LETTER 5014914 69 of 99 Proposed Rev. 4.C (for renewal)

HI-STAR FSAR Rev. 4 HI-2012610 2.4-1 2.4 DECOMMISSIONING CONSIDERATIONS Efficient decommissioning of the ISFSI is a paramount objective of the HI-STAR 100 System. The HI-STAR 100 System is ideally configured to facilitate rapid, safe, and economical decommissioning of the storage site.

The MPC which holds the SNF assemblies is engineered to be suitable as a waste package for permanent internment in a deep Mined Geological Disposal System (MGDS). The materials of construction permitted for the MPC are known to be highly resistant to severe environmental conditions. No carbon steel, paint, or coatings are used or permitted in the MPC in areas where they could be exposed to spent fuel pool water or the ambient environment. Therefore, the SNF assemblies stored in the MPC should not need to be removed. However, to ensure a practical, feasible method to defuel the HI-STAR 100 MPC, the top of the MPC is equipped with sufficient gamma shielding and markings locating the drain and vent locations to enable semiautomatic (or remotely actuated) boring of the MPC lid to provide access to the MPC vent and drain. The circumferential welds of the MPC lid and closure ring can be removed by semiautomatic or remotely actuated means, providing access to the SNF.

Likewise, the overpack consists of alloy materials rendering it suitable for permanent burial.

Alternatively, the MPC can be removed from the overpack, and the latter reused for storage or transportation of other MPCs.

In either case, the overpack would be expected to have only minimal interior or exterior radioactive surface contamination. Any neutron activation of the metal cask walls and neutron shielding is expected to be extremely small, and the assembly would qualify as Class A waste in a stable form based on definitions and requirements in 10CFR61.55. As such, the material would be suitable for burial in a near-surface disposal site as Low Specific Activity (LSA) material.

If the HI-STAR 100 MPC needs to be opened and separated from the SNF before the fuel is placed into the MGDS, the MPC interior metal surfaces will be decontaminated using existing mechanical or chemical methods. This will be facilitated by the MPC fuel basket and interior structures' smooth metal surfaces designed to minimize crud traps. After the surface contamination is removed, the MPC radioactivity will be diminished significantly, allowing near-surface burial or secondary applications at the licensee's facility.

It is also likely that both the overpack and MPC, or extensive portions of both, can be further decontaminated to allow recycle or reuse options. After decontamination, the only radiological hazard the HI-STAR 100 System may pose is slight activation of the HI-STAR 100 materials caused by irradiation over a 6050-year storage period. Table 2.4.1 provides the conservatively determined quantities of the major nuclides after 50 and 60 years of irradiation.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 70 of 99 Proposed Rev. 4.C (for renewal)

HI-STAR FSAR Rev. 4 HI-2012610 2.4-3 Table 2.4.1 HI-STAR 100 SYSTEM ACTIVATION HI-STAR 100 Component Nuclide Curies After 50-Year Storage Curies After 60-Year Storage MPC 54Mn 1.79E-3 2.15E-3 55Fe 2.88E-3 3.46E-3 59Ni 2.36E-3 2.83E-3 60Co 2.53E-3 3.04E-3 63Ni 8.04E-3 9.65E-3 Total 1.76E-2 2.11E-2 Overpack 54Mn 2.24E-3 2.69E-3 55Fe 11.11E-3 1.33E-2 59Ni N/A N/A 60Co N/A N/A 63Ni N/A N/A Total 1.34E-2 1.61E-2 Total HI-STAR 100 System 3.10E-2 3.72E-2 ATTACHMENT 1 TO HOLTEC LETTER 5014914 71 of 99 Proposed Rev. 4.C (for renewal)

HI-STAR FSAR Rev. 4 REPORT HI-2012610 3.4-57 Appendix 3.A provides a description of the dynamic finite element analyses undertaken to establish the decelerations resulting from the postulated event. A non-mechanistic tip-over is considered together with a side and end drop of a loaded HI-STAR 100 System. A dynamic finite element analysis of each event is performed using a commercial finite element code well suited for such dynamic analyses with interface impact and non-linear material behavior. This code and methodology have been fully benchmarked against Lawrence Livermore Laboratories test data and correlation [3.4.12].

It is shown in Appendix 3.A that the peak deceleration is less than 60g's for tip-over. Table 3.A.3 shows that the maximum deceleration level at the top of the cask is 66.0 g's, while the corresponding deceleration level at the top of the fuel basket is 59.8 g's. For the case of a vertical drop from a height of 21" (533 mm), the bounding longitudinal deceleration is 52.3 g's. Finally, for a side drop from a height of 72 (1,829 mm), the maximum deceleration is 49.7 gs.

Based on the above results, it is concluded that the design basis deceleration limit of 60g's (Table 3.1.2) provides a conservative input for Level D stress calculations to demonstrate retrievability of stored fuel.

3.4.10 Overpack Service Life The term of the 10CFR72, Subpart L C of C, granted by the NRC is 20 years. Nonetheless, the HI-STAR 100 Overpack is designed for 640 years of service life, while satisfying the conservative design requirements defined in Chapter 2, including the regulatory requirements of 10CFR72. In addition, the overpack is designed, fabricated, and inspected under the comprehensive Quality Assurance Program discussed in Chapter 13 and in accordance with the applicable requirements of the ASME Codes. The pressure boundary (helium retention boundary) of the overpack is engineered to meet ASME Section III, Subsection NB (Class 1) stress intensity limits. Even though compliance to a less rigorous standard (such as the AISC Manual for Steel Construction) would be acceptable, all structural members of the HI-STAR 100 overpack located outside of the pressure boundary meet ASME Section III, Subsection NF stress limits. The aforementioned design and manufacturing measures assure high design margins, high quality fabrication, and verification of compliance through rigorous inspection and testing, as describe in Chapter 9. Technical Specifications defined in Chapter 12 assure that the integrity of the cask and the contained MPC are maintained throughout the components' service life.

The principal design considerations which bear on the adequacy of the overpack for the design basis service life are addressed as follows:

Exposure to Environmental Effects All exposed surfaces of HI-STAR 100 are made from ferritic steels that are readily painted.

Therefore, the potential of environmental vagaries are ruled out for HI-STAR 100. Under normal storage conditions, the bulk temperature of the HI-STAR 100 overpack will, because of its large thermal inertia, change very gradually with time. Therefore, material degradation from rapid thermal ramping conditions is not credible for the HI-STAR 100 overpack. The configuration of the overpack assures resistance to freeze-thaw degradation. In addition, the overpack is ATTACHMENT 1 TO HOLTEC LETTER 5014914 72 of 99 Proposed Rev. 4.C (for renewal)

HI-STAR FSAR Rev. 4 REPORT HI-2012610 3.4-58 specifically designed for a full range of enveloping design basis natural phenomena which could occur over the 640-year service life of the overpack as defined in Section 2.2.3 and evaluated in Chapter 11.

Material Degradation The relatively low neutron flux to which the overpack is subjected cannot produce measurable degradation of the cask's material properties and impair its intended safety function. Exposed carbon steel components are coated to prevent corrosion. The controlled environment of the ISFSI storage pad mitigates damage due to direct exposure to corrosive chemicals that may be present in other industrial applications.

Maintenance and Inspection Provisions The requirements for periodic inspection and maintenance of the overpack throughout the 40-year service life are defined in Chapter 9. These requirements include provisions for routine inspection of the overpack exterior. ISFSIs located in areas subject to atmospheric conditions which may degrade the storage cask or canister should be evaluated by the licensee on a site-specific basis to determine the frequency for such inspections to assure long-term performance.

In addition, the HI-STAR 100 System is designed for easy retrieval of the MPC from the overpack should it become necessary to perform more detailed inspections and repairs on the overpack.

The above findings are consistent with those of the NRC's Waste Confidence Decision Review

[3.4.11], which concluded that dry storage systems designed, fabricated, inspected, and operate in accordance with such requirements are adequate for a 100-year service life while satisfying the requirements of 10CFR72.

3.4.11 MPC Service Life The term of the 10CFR72, Subpart L C of C, granted by the NRC is 20 years. Nonetheless, the HI-STAR 100 MPC is designed for 640 years of service, while satisfying the conservative design requirements defined in Chapter 2, including the regulatory requirements of 10CFR72.

Additional assurance of the integrity of the MPC and the contained SNF assemblies throughout the 40-year service life of the MPC is provided through the following:

Design, fabrication, and inspection in accordance with the applicable requirements of the ASME Code as described in Chapter 2 assures high design margins.

Fabrication and inspection performed in accordance with the comprehensive Quality Assurance program discussed in Chapter 13 assures competent compliance with the fabrication requirements.

Use of materials with known characteristics, verified through rigorous inspection and testing, as described in Chapter 9, assures component compliance with design requirements.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 73 of 99 Proposed Rev. 4.C (for renewal)

HI-STAR FSAR Rev. 4 REPORT HI-2012610 3.4-59 Use of welding procedures in full compliance with Sections III and IX of the ASME Code ensures high quality weld joints.

Technical Specifications, as defined in Chapter 12, have been developed and imposed on the MPC which assure that the integrity of the MPC and the contained SNF assemblies are maintained throughout the 640-year service life of the MPC.

The principal design considerations bearing on the adequacy of the MPC for the design basis service life are summarized below.

Corrosion All MPC materials are fabricated from corrosion-resistant austenitic stainless steel and passivated aluminum. The corrosion-resistant characteristics of such materials for dry SNF storage canister applications, as well as the protection offered by these materials against other material degradation effects, are well established in the nuclear industry. The MPC is vacuum dried to remove all oxidizing liquids and gases and backfilled with dry inert helium at the time of closure to maintain an atmosphere in the MPC that provides corrosion protection for the SNF cladding throughout the dry storage period. The preservation of this non-corrosive atmosphere is assured by the inherent sealworthiness of the MPC confinement boundary integrity (there are no gasketed joints in the MPC).

Structural Fatigue The passive non-cyclic nature of dry storage conditions does not subject the MPC to conditions that might lead to structural fatigue failure. Ambient temperature and insolation cycling during normal dry storage conditions and the resulting fluctuations in MPC thermal gradients and internal pressure is the only mechanism for fatigue. These low stress, high-cycle conditions cannot lead to a fatigue failure of the MPC which is made from stainless alloy stock (endurance limit well in excess of 20,000 psi (138 MPa)). All other off-normal or postulated accident conditions are infrequent or one-time occurrences which cannot produce fatigue failures. Finally, the MPC uses materials that are not susceptible to brittle fracture.

Maintenance of Helium Atmosphere The inert helium atmosphere in the MPC provides a non-oxidizing environment for the SNF cladding to assure its integrity during long-term storage. The preservation of the helium atmosphere in the MPC is assured by the robust design of the MPC confinement boundary described in Section 7.1. Maintaining an inert environment in the MPC mitigates conditions that might otherwise lead to SNF cladding failures. The required mass quantity of helium backfilled into the canister at the time of closure as defined in the Technical Specification contained in Chapter 12, and the associated leak tightness requirements for the canister defined in the Technical Specification contained in Chapter 12, are specifically set down to assure that an inert helium atmosphere is maintained in the canister throughout a 40-year service life.

Allowable Fuel Cladding Temperatures ATTACHMENT 1 TO HOLTEC LETTER 5014914 74 of 99 Proposed Rev. 4.C (for renewal)

HI-STAR FSAR Rev. 4 REPORT HI-2012610 3.4-60 The helium atmosphere in the MPC promotes heat removal and thus reduces SNF cladding temperatures during dry storage. In addition, the SNF decay heat will substantially attenuate over a 40-year dry storage period. Maintaining the fuel cladding temperatures below allowable levels during long-term dry storage mitigates the damage mechanism that might otherwise lead to SNF cladding failures. The allowable long-term SNF cladding temperatures used for thermal acceptance of the MPC design are conservatively determined, as discussed in Section 4.3.

Neutron Absorber Boron Depletion The effectiveness of the fixed borated neutron absorbing material used in the MPC fuel basket design requires that sufficient concentrations of boron be present to assure criticality safety during worst case design basis conditions over the 40-year service life of the MPC. Information on the characteristics of the borated neutron absorbing material used in the MPC fuel basket is provided in Section 1.2.1.3.1. The low neutron flux, which will continue to decay over time, to which this borated material is subjected, does not result in depletion of the material's available boron to prevent performing its intended safety function. In addition, the boron content of the material used in the criticality safety analysis is conservatively based on the minimum specified boron areal density (rather than the nominal), which is further reduced by 25% for analysis purposes, as described in Section 6.1. Analysis discussed in Section 6.3.2 demonstrates that the boron depletion in the neutron absorber material is negligible over a 650-year duration. Thus, sufficient levels of boron are present in the fuel basket neutron absorbing material to maintain criticality safety functions over the 40-year service life of the MPC.

The above findings are consistent with those of the NRC's Waste Confidence Decision Review, which concluded that dry storage systems designed, fabricated, inspected, and operated in the manner of the requirements set down in this document are adequate for a 100-year service life, while satisfying the requirements of 10CFR72.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 75 of 99 Proposed Rev. 4.C (for renewal)

Table 3.7.1 (continued)

COMPLIANCE OF HI-STAR 100 SYSTEM WITH 10CFR72.236(e), ET AL.

HI-STAR FSAR Rev. 4 REPORT HI-2012610 3.7-7 Item Compliance Location of Supporting Information in This Document

i.

Redundant sealing of confinement systems Two physically independent lids, each separately welded to the MPC shell (Enclosure Vessel shell) provide a redundant confinement system.

Section 1.5 Drawing Nos. 1392, 1395, and 1401; Figure 7.1.2 Section 7.1.

ii.

Adequate heat removal without active cooling systems.

Thermal analyses presented in Chapter 4 show that the HI-STAR 100 System will remove the decay heat generated from the stored spent fuel by strictly passive means and maintain the system temperature within prescribed limits.

Sections 4.4 and Sections 9.1 and 9.2 iii.

Storage of spent fuel for a

minimum of 20 years.

The service life of the overpack and MPC are engineered to be in excess of 20 years, with renewed license up to 60 years.

Subsections 3.4.10 and 3.4.11 iv.

Compatibility with wet or dry spent fuel loading and unloading facilities The system is designed to eliminate any significant material interactions in the wet (spent fuel pool) environment.

Subsection 3.4.1

v.

Ease of decontamination The external surface of the multi-purpose canister is protected from contamination during fuel loading through a custom designed sealing device.

Figures 8.1.13 and 8.1.14 vi.

Inspections of defects that might reduce confinement effectiveness.

Post-fabrication inspection of the shielding materials will be performed to ensure that no HI-STAR 100 Systems containing unacceptable voids are deployed at the ISFSI for long-term storage.

Section 9.1 and Chapter 12 vii.

Conspicuous and durable marking.

The stainless steel lid of each MPC will have model number and serial number engraved for ready identification.

Section 1.5 ATTACHMENT 1 TO HOLTEC LETTER 5014914 76 of 99 Proposed Rev. 4.C (for renewal)

HI-STAR FSAR Rev. 4 REPORT HI-2012610 6.1-1 6.1 DISCUSSION AND RESULTS In conformance with the principles established in NUREG-1536 [6.1.1], 10CFR72.124 [6.1.2],

and NUREG-0800 Section 9.1.2 [6.1.3], the results in this chapter demonstrate that the effective multiplication factor (keff) of the HI-STAR 100 System, including all biases and uncertainties evaluated with a 95% probability at the 95% confidence level, does not exceed 0.95 under all credible normal, off-normal, and accident conditions. Moreover, these results demonstrate that the HI-STAR 100 System is designed and maintained such that at least two unlikely, independent, and concurrent or sequential changes must occur to the conditions essential to criticality safety before a nuclear criticality accident is possible. These criteria provide a large subcritical margin, sufficient to assure the criticality safety of the HI-STAR 100 System when fully loaded with fuel of the highest permissible reactivity.

Criticality safety of the HI-STAR 100 System depends on the following principal design parameters:

1.

The inherent geometry of the fuel basket designs within the MPC (and the flux-trap water gaps in the MPC-24);

2.

The incorporation of permanent fixed neutron-absorbing panels in the fuel basket structure;

3.

An administrative limit on the maximum enrichment for PWR fuel and maximum planar-average enrichment for BWR fuel; and

4.

An administrative limit on the minimum soluble boron concentration in the water for loading/unloading fuel with higher enrichments in the MPC-24, and for loading/unloading fuel in the MPC-32.

The normal conditions for loading/unloading, handling, packaging, transfer, and storage of the HI-STAR 100 System conservatively include: full flooding with ordinary water corresponding to the highest reactivity, and the worst case (most conservative) combination of manufacturing and fabrication tolerances. The off-normal and accident conditions defined in Chapter 2 and considered in Chapter 11 have no adverse effect on the design parameters important to criticality safety, and thus, the off-normal and accident conditions are identical to those for normal conditions.

The HI-STAR 100 System is designed such that the fixed neutron absorber will remain effective for a storage period greater than 6020 years, and there are no credible means to lose it. Therefore, in accordance with 10CFR72.124(b), there is no need to provide a surveillance or monitoring program to verify the continued efficacy of the neutron absorber.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 77 of 99

HI-STAR FSAR Rev. 4 REPORT HI-2012610 6.3-3 thicknesses and the results are compared in Table 6.3.5. To bound various soluble boron levels, two comparisons were performed. The first comparison uses the bounding case for the MPC-32 (see Table 6.1.6), which is for assembly class 15x15F at 5 wt% 235U and a soluble boron level of 2600 ppm. To bound lower soluble boron levels, the second comparison uses the same assembly class (15x15F), 0 ppm soluble boron (i.e. pure water), and an arbitrary enrichment of 1.7 wt%

235U. In both comparisons, the results of the 0.075 inch (0.1905 cm) sheathing are slightly higher, i.e. more conservative, than the results for 0.035 inch (0.0889 cm) sheathing, although the differences are within the statistical uncertainties. Using a sheathing thickness of 0.075 inches (0.1905 cm) in the criticality models of the MPC-32 is therefore acceptable, and potentially more conservative, than using the actual value of 0.035 inches (0.0889 cm). This validates the choice of the dimensional assumptions for the MPC-32 shown in Table 6.3.3, which are used for all further MPC-32 criticality calculations, unless otherwise noted.

6.3.2 Cask Regional Densities Composition of the various components of the principal designs of the HI-STAR 100 Systems are listed in Table 6.3.4.

The HI-STAR 100 System is designed such that the fixed neutron absorber will remain effective for a storage period greater than 20 years, and there are no credible means to lose it. A detailed physical description, historical applications, unique characteristics, service experience, and manufacturing quality assurance of fixed neutron absorber are provided in Section 1.2.1.3.1.

The continued efficacy of the fixed neutron absorber is assured by acceptance testing, documented in Section 9.1.5.3, to validate the 10B (poison) concentration in the fixed neutron absorber. To demonstrate that the neutron flux from the irradiated fuel results in a negligible depletion of the poison material over the storage period, an MCNP4a calculation of the number of neutrons absorbed in the 10B was performed. The calculation conservatively assumed a constant neutron source for 650 years equal to the initial source for the design basis fuel, as determined in Section 5.2, and shows that the fraction of 10B atoms destroyed is only 2.63.2E-09 in 650 years. Thus, the reduction in 10B concentration in the fixed neutron absorber by neutron absorption is negligible. In addition, analysis in Appendix 3.M.1 demonstrates that the sheathing, which affixes the fixed neutron absorber panel, remains in place during all credible accident conditions, and thus, the fixed neutron absorber panel remains permanently fixed. Therefore, in accordance with NUREG-1536, there is no need to provide a surveillance or monitoring program to verify the continued efficacy of the neutron absorber, as required by 10CFR72.124(b).

6.3.3 Eccentric Positioning of Assemblies in Fuel Storage Cells Up to and including Revision 3 of this FSAR, all criticality calculations were performed with fuel assemblies centered in the fuel storage locations since the effect of credible eccentric fuel ATTACHMENT 1 TO HOLTEC LETTER 5014914 78 of 99

HI-STAR FSAR Rev. 4 REPORT HI-2012610 6.6-1 6.6 REGULATORY COMPLIANCE This chapter documents the criticality evaluation of the HI-STAR 100 System for the storage of spent nuclear fuel. This evaluation demonstrates that the HI-STAR 100 System is in full compliance with the criticality requirements of 10CFR72 and NUREG-1536.

Structures, systems, and components important to criticality safety are described in sufficient detail in this chapter to enable an evaluation of their effectiveness.

The HI-STAR 100 System is designed to be subcritical under all credible conditions. The criticality design is based on favorable geometry and fixed neutron poisons. An appraisal of the fixed neutron poisons has shown that they will remain effective for a storage period greater than 20 60 years, and there is no credible way to lose it, therefore there is no need to provide a positive means to verify their continued efficacy as required by 10CFR72.124(b).

The criticality evaluation has demonstrated that the cask will enable the storage of spent fuel for a minimum of 20 years with an adequate margin of safety. Further, the evaluation has demonstrated that the design basis accidents have no adverse effect on the design parameters important to criticality safety, and therefore, the HI-STAR 100 System is in full compliance with the double contingency requirements of 10CRF72.124. Therefore, it is concluded that the criticality design features for the HI-STAR 100 System are in compliance with 10 CFR Part 72 and that the applicable design and acceptance criteria have been satisfied. The criticality evaluation provides reasonable assurance that the HI-STAR 100 System will allow safe storage of spent fuel.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 79 of 99 Proposed Rev. 4.C (for renewal)

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.2-1 9.2 MAINTENANCE PROGRAM AND AGING MANAGEMENT PROGRAM An ongoing maintenance program shall be defined and incorporated into the HI-STAR 100 System Operations Manual which shall be prepared and issued prior to the delivery and first use of the system to each user. This document shall delineate the detailed inspections, testing, and parts replacement necessary to ensure continued structural, thermal and confinement performance; radiological safety, and proper handling of the system in accordance with 10CFR72 [9.0.1]

regulations, the conditions specified in the Certificate of Compliance, and the design requirements and criteria contained in this FSAR.

The HI-STAR 100 System is totally passive by design. There are no active components or monitoring systems required to assure the continued performance of its safety functions. As a result, only minimal maintenance will be required over the HI-STAR 100 System's lifetime, and this maintenance would primarily result from the weathering effects on the exterior coating system while in storage. Typical of such maintenance would be the reapplication of corrosion inhibiting materials on accessible external surfaces. Such maintenance requires methods and procedures no more demanding than those currently in use at licensed facilities.

Maintenance activities shall be performed under the licensees NRC-approved quality assurance program. Maintenance activities shall be administratively controlled and the results documented.

The maintenance program schedule for the HI-STAR 100 System is provided in Table 9.2.1.

9.2.1 Structural and Pressure Parts Prior to each fuel loading, a visual examination in accordance with written and approved procedures shall be performed on the lifting trunnions (area outside of the overpack) and pocket trunnion recesses, if used. The examination shall inspect for indications of overstress such as cracking, deformation, or wear marks. Repairs or replacement in accordance with written and approved procedures shall be required if unacceptable conditions are identified.

As described in FSAR Chapters 7 and 11, there are no credible normal, off-normal, or accident events which can cause the structural failure of the MPC or HI-STAR overpack. Therefore, periodic structural or pressure tests on the MPCs or HI-STAR overpack following the initial acceptance tests are not required as part of the storage maintenance program.

9.2.2 Leakage Tests There are no seals or gaskets that comprise the MPC confinement boundary since the MPC lid, port cover plates, and closure ring are welded closures. Metallic seals are used on the overpack helium retention boundary to ensure the retention of the helium in the overpack. These seals are not temperature sensitive within the design temperature range, are resistant to corrosion and radiation environments, and are helium leak tested after fuel loading. There are no credible normal, off-normal, or accident events which can cause the failure of the MPC confinement boundary or overpack helium retention boundary seals or welds. No leakage tests are required as part of the storage maintenance program.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 80 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.2-2 Prior to transport of the HI-STAR 100 System following completion of the storage period, a Containment Periodic Verification leakage test shall be performed in accordance with ANSI N14.5

[9.1.9] and the HI-STAR 100 Safety Analysis Report [9.1.4] to verify the continued integrity of the containment boundary metallic seals.

9.2.3 Subsystem Maintenance The HI-STAR 100 System does not include any subsystems which provide auxiliary cooling.

Normal maintenance and calibration testing will be required on the vacuum drying, helium backfill, and leakage testing systems. Rigging, remote welders, cranes, and lifting beams shall also be inspected prior to each loading campaign to ensure proper maintenance and continued performance is achieved. Auxiliary shielding provided during on-site transfer operations or installed with the HI-STAR 100 at the storage pad requires no maintenance.

9.2.4 Rupture disks The rupture disks shall be replaced as described in Table 9.2.1 with approved spares per written and approved procedures.

9.2.5 Shielding The gamma and neutron shielding materials in the overpack and MPC degrade negligibly over time or as a result of usage. To ensure continuing compliance of the HI-STAR 100 System to the design basis dose rate values, the Shielding Effectiveness Test shall be reperformed as described in Table 9.2.1 after placement into service. After the first 20 years of serviceWhen the site implements an aging management program, this inspection is replaced by the Overpack Aging Management Program.

Radiation monitoring of the ISFSI by the licensee in accordance with 10CFR72.104(c) provides ongoing evidence and confirmation of the shielding integrity and performance. If increased radiation doses are indicated by the facility monitoring program, additional surveys of overpacks shall be performed to determine the cause of the increased dose rates.

The neutron absorber panels installed in the MPC baskets are not expected to degrade under normal long-term dry storage conditions. The use of Boral in similar nuclear applications is discussed in Chapter 1, and the long-term performance in a dry, inert gas atmosphere is evaluated in Chapter 3. A similar discussion is provided for METAMIC neutron absorber material. Therefore, no periodic verification testing of neutron poison material is required on the HI-STAR 100 System.

9.2.6 Thermal There are no active cooling systems required for the long-term thermal performance of the HI-STAR 100 System. Therefore, no periodic thermal testing is required for the HI-STAR 100 System.

9.2.7 Aging Management Program ATTACHMENT 1 TO HOLTEC LETTER 5014914 81 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.2-3 An aging management assessment of the components of the HI-STAR 100 system was performed.

This review identified inspection and monitoring activities necessary to provide reasonable assurance that system components within the scope of license renewal continue to perform their intended functions consistent with the current licensing basis for the renewed operating period. This section describes these aging management programs.

9.2.7.1 Overpack Aging Management Program The Overpack Aging Management Program involves monitoring the exterior surface of each of the HI-STAR 100 overpacks for signs of degradation. A visual examination in accordance with the maintenance program described in Section 9.2.2 is performed annually. Additionally, a VT-3 inspection in accordance with ASME Code,Section XI, Article IWA-2213 is performed every 5 years.

Visual inspections will look for:

Visual evidence of discontinuities, imperfections, and rust staining indicative of corrosion, SCC, and wear Visual evidence of loose or missing bolts, physical displacement, and other conditions indicative of loss of preload Visual evidence of coating degradation (e.g., blisters, cracking, flacking, delamination) indicative of corrosion of the base metal Additionally, the Overpack Aging Management Program involves a shielding effectiveness test, following the same procedure as the test described in Table 9.2.12, performed every 5 years.

The full description of the Overpack Aging Management Program is contained in Table 9.2.2.

9.2.7.2 ISFSI Pad Aging Management Program The ISFSI Pad Aging Management Program involves monitoring the condition of the ISFSI pad. An annual inspection is performed in accordance with ACI-349. This visual inspection identifies the current condition of the pad and can identify the extent and cause of any aging effect noted. The acceptance criteria for this program are defined in ACI-349.3R-02.

The full description of the ISFSI Pad Aging Management Program is contained in Table 9.2.3.

9.2.7.3 Tollgates Tollgates are established as requirements in the renewed CoC, and implemented by ISFSI generic licensees to evaluate aging management feedback and perform a safety assessment that confirms the safe storage of spent nuclear fuel. The impact of the aggregate feedback will be assessed by the site as it pertains to components at the sites ISFSI and actions taken as necessary, such as:

Adjustment of aging-related degradation monitoring and inspection programs in AMPs Modification of TLAAs Performance of mitigation activities ATTACHMENT 1 TO HOLTEC LETTER 5014914 82 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.2-4 Each tollgate assessment will address the following elements as applicable:

Summary of research findings, operating experience, monitoring data, and inspection results made available since last assessment Aggregate impact of findings, including any trends Consistency of data with the assumptions and inputs in the TLAAs Effectiveness of AMPs Corrective actions, including any changes to AMPs Summary and conclusions A schedule for these tollgate assessments is shown in Table 9.2.4.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 83 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.2-5 Table 9.2.1 HI-STAR 100 SYSTEM MAINTENANCE PROGRAM SCHEDULE Task Frequency Overpack cavity visual inspection Prior to fuel loading Overpack bolt visual inspection Prior to installation during each use Overpack external surface (accessible) visual examination Annually HI-STAR 100 System Shield Effectiveness Test After loading and every 5 years Lifting trunnion and pocket trunnion recess visual inspection Prior to next handling operation after loaded HI-STAR 100 System is placed on ISFSI pad.

Closure plate seal replacement Following removal of closure plate bolting Port seal replacement Following opening of applicable port Port cover plate seal replacement Following removal of applicable cover plate Replace neutron shield vessel rupture disks Every 5 years ATTACHMENT 1 TO HOLTEC LETTER 5014914 84 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.2-6 Table 9.2.2 OVERPACK AGING MANAGEMENT PROGRAM Element Description

1. Scope of Program The program covers the subcomponents of the HI-STAR 100 Overpack identified in Table 3.3-3 of [9.2.1] which require the HI-STAR 100 Overpack AMP, to operate into the extended storage period.
2. Preventative Actions This AMP uses condition monitoring to manage aging effects. The design of the system is intended to minimize aging effects on the system, but this AMP focuses on condition monitoring and detecting any evidence of degradation. No new preventative actions are included in this AMP.
3. Parameters Monitored /

Inspected The condition of the exterior of each in-service cask is inspected visually to ensure the intended functions of the cask exterior are not compromised. Visual inspections will look for:

Visual evidence of discontinuities, imperfections, and rust staining indicative of corrosion, SCC, and wear Visual evidence of loose or missing bolts, physical displacement, and other conditions indicative of loss of preload Visual evidence of coating degradation (e.g., blisters, cracking, flacking, delamination) indicative of corrosion of the base metal

4. Detection of Aging Effects Readily Accessible Surfaces Annual Examination A visual inspection of all normally accessible portions of the exterior surface of the overpack provides a means to detect degradation of these components due to a potential loss of material and confirm that the intended functions are not compromised. This visual inspection shall be performed on all HI-STAR 100 casks annually. This inspection was required for the initial license period, per FSAR Table 9.2.1, so it is recommended that users follow their existing inspection procedures for these annual inspections.

5 Year Code Inspection Once every 5 years, visual inspections are performed in accordance with ASME Code Section XI, Article IWA-2213, for VT-3 examinations, and cover all normally accessible surfaces on all casks. This visual inspection is conducted by a qualified individual.

Shielding Effectiveness A shielding effectiveness test shall be performed every five years on each overpack. Calibrated neutron and gamma dose meters shall be used to measure the actual neutron and gamma dose rates at the surface of the HI-STAR overpack.

Measurements will be taken at three cross-sectional planes and at four points along each planes circumference. Additionally, four measurements shall be ATTACHMENT 1 TO HOLTEC LETTER 5014914 85 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.2-7 taken at the top of the overpack closure plate. The average results from each sectional plane shall be compared to the design basis limits for surface dose rates established in the HI-STAR 100 FSAR Chapter 5. This test was required for the initial license period, per FSAR Table 9.1.2 (although the frequency may have been different), so it is recommended that users follow their existing test procedures.

Data Collection Data from the visual examinations and shielding effectiveness test shall be documented on a checklist or inspection form. The results of the inspection shall be documented, including descriptions of observed aging effects and supporting sketches, photographs, or video. Corrective actions resulting from each AMP inspection shall also be documented.

Timing Annual external examinations and shielding effectiveness tests are continued from the initial period of operation.

The first 5 year code inspection should be performed when the cask enters its period of extended operation. If the cask is already in its period of extended operation (due to timely renewal) or within 365 days of entering its period of extended operation when the renewed license is issued, the site has 365 days to complete the first 5 year code inspection from the issuance of the renewed license.

5. Monitoring and Trending The inspections and tests described for external subcomponents of the HI-STAR 100 are performed periodically in order to identify areas of degradation. The visual inspection results will be evaluated by a qualified individual, and areas of degradation not meeting established criteria will be entered into the site Corrective Action Program (CAP) for resolution or more detailed evaluation. The shielding test results shall be compared to the acceptance criteria (described below), and results not meeting these criteria will be entered into the site CAP for resolution or more detailed evaluation. The results from both the visual inspection and shielding tests will be compared against previous inspections in order to monitor and trend the progression of the aging effects over time.
6. Acceptance Criteria External Visual Inspection The acceptance criteria for the visual inspections are:

No detectable loss of material from the base metal, including uniform wall thinning, localized corrosion pits, and crevice corrosion No red-orange-colored corrosion products on the base metal or coatings No coating defects (e.g., blisters, cracking, flaking, delamination)

No indications of loose bolts or hardware, displaced parts No evidence of corrosion such as rust on the ISFSI pad concrete in the area adjacent to the overpack If evidence of corrosion, wear, or coating degradation is identified, then the ATTACHMENT 1 TO HOLTEC LETTER 5014914 86 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.2-8 severity of the degradation must be determined using approved site-specific procedures. These may include additional visual, surface, or volumetric non destructive examination methods to determine the loss of material.

Shielding Effectiveness Test The dose rate measurements described above shall be compared to the design basis limits for surface dose rates from the HI-STAR 100 FSAR Chapter 5. The test results are considered acceptable if the actual dose readings are lower or equal to the acceptance criteria in the Technical Specifications. If dose rates are higher than the Technical Specification limits, the required actions of the Technical Specifications shall be completed.

7. Corrective Actions The corrective actions performed based on any detected aging effects are in accordance with the sites Quality Assurance (QA) program. The QA Program ensures that corrective actions are completed within the sites Corrective Action Program (CAP).

As applicable, the CAP program will perform cause evaluations, address the extent of condition, determine any necessary actions to prevent recurrence, identify any changes to the existing AMP, and determine if the condition is reportable.

The CAP program corrective actions will also identify the actions needing to be taken for increased scope or frequency of inspections, as necessary, based on any detected aging effects. One potential corrective action, if significant exterior corrosion is found in the area, could be to perform additional inspections of inaccessible surfaces, such as the bottom of the cask.

8. Confirmation Process The confirmation process will be commensurate with the site QA Program. The QA program ensures that inspections, evaluations, and corrective actions are completed in accordance with the site CAP.
9. Administrative Controls The site QA program and implementing procedures for this AMP will address instrument calibration and maintenance, inspector requirements, record retention requirements, and document control.

This AMP will be updated periodically, as necessary, based on the toll gate assessments described in Chapter 4 of this application. Inspection results will be documented and made available for NRC inspectors to view upon request.

10. Operating Experience Previous Operating Experience The sites have utilized the same HI-STAR 100 casks since they were initially loaded. Both the periodic visual inspections and periodic shielding effectiveness tests have not shown any aging related degradation of the system.

Future Operating Experience As the inspections are performed, sites will upload information into the INPO AMID database to be shared with other users.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 87 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.3-1 Table 9.2.3 ISFSI PAD AGING MANAGEMENT PROGRAM Element Description

1. Scope of Program The program covers the subcomponents of the ISFSI Pad identified in Table 3.3-.5 of [9.2.1] which require the ISFSI Pad AMP, to operate into the extended storage period. The scope covers inspections of the above grade areas of the pad which are readily accessible and monitoring for the below grade portions exposed to foundation soil, backfill, or groundwater per the requirements described in ACI 349.3R-02/
2. Preventative Actions This AMP uses condition monitoring to manage aging effects. The design of the ISFSI Pad is intended to minimize aging effects on the system, but this AMP focuses on condition monitoring. No new preventative actions are included in this AMP.
3. Parameters Monitored /

Inspected The ISFSI Pad above -grade exposed surfaces are visually examined for cracking, loss of material (spalling, scaling), loss of bond, and increased porosity/permeability. The below-grade portions of the pad exposed to soil environments are monitored in accordance with ACI 349.3R-02.

Degradation could affect the ability of the concrete pad to provide support to the casks over the period of extended storage. The pad itself does not have any safety function, but may impact the storage of the casks.

4. Detection of Aging Effects The ISFSI Pad AMP is a visual inspection of all readily accessible surfaces in order to detect any aging effects. The visual survey in accordance with ACI-349.3R-02, should identify the source of any staining or corrosion-related activity and the degree of damage. This visual inspection identifies the current condition of the pad and can identify the extent and cause of any aging effect noted. This visual inspection is conducted every 5 years by a qualified individual. Visual inspections of below grade areas are performed on an opportunistic basis, only when excavations in the area occur.

Timing The first ISFSI pad inspection (of above-grade areas) should be performed when the first cask on the pad enters its period of extended operation. If the cask is already in its period of extended operation (due to timely renewal) or within 365 days of entering its period of extended operation when the renewed license is issued, the site has 365 days to complete the first 5 year code inspection from the issuance of the renewed license.

Technical evaluation of below grade materials based on activities described in ACI 349.3R-02, such as ground water chemistry or opportunistic visual inspections should be performed and documented at periodic intervals of 10 years.

5. Monitoring and Trending The inspection described for the ISFSI pad is performed periodically in order to identify areas of degradation. The results will be evaluated by a qualified individual, and areas of degradation not meeting established ATTACHMENT 1 TO HOLTEC LETTER 5014914 88 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.3-2 criteria will be entered into the site CAP for resolution or more detailed evaluation. The results will be compared against previous inspections in order to monitor and trend the progression of the aging effects over time.

6. Acceptance Criteria American Concrete Institute Standard 349.3R-02 includes quantitative three-tier acceptance criteria for visual inspections of concrete surfaces, namely (1) acceptance without further evaluation, (2) acceptance after review, (3) acceptance requiring further evaluation. Acceptable signifies that a component is free of significant deficiencies or degradation that could lead to the loss of structural integrity. Acceptable after review signifies that a component contains deficiencies or degradation but will remain able to perform its design basis function until the next inspection or repair. Acceptance requiring further evaluation signifies that a component contains deficiencies or degradation that could prevent (or could prevent prior to the next inspection) the ability to perform their design basis function. Degradations or conditions meeting the ACI349.3R-02 Tier 2 and 3 criteria will be entered into the sites CAP for evaluation and resolution. Should the site determine there is a need to deviate from the ACI394.3R-02 acceptance criteria; a technical justification will be fully documented.
7. Corrective Actions The corrective actions performed based on any detected aging effects are in accordance with the sites Quality Assurance (QA) program. The QA Program ensures that corrective actions are completed within the sites Corrective Action Program (CAP).

As applicable, the CAP program will perform cause evaluations, address the extent of condition, determine any necessary actions to prevent recurrence, identify any changes to the existing AMP, and determine if the condition is reportable.

The CAP program corrective actions will also identify the actions needing to be taken for increased scope or frequency of inspections, as necessary, based on any detected aging effects.

8. Confirmation Process The confirmation process will be commensurate with the site QA Program.

The QA program ensures that inspections, evaluations, and corrective actions are completed in accordance with the site CAP.

9. Administrative Controls The site QA program and implementing procedures for this AMP will address instrument calibration and maintenance, inspector requirements (commensurate with ACI 349.3R-02), record retention requirements, and document control.

This AMP will be updated periodically, as necessary, based on the toll gate assessments described in Chapter 4 of this application. Inspection results will be documented and made available for NRC inspectors to view upon request.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 89 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.3-3

10. Operating Experience Previous Operating Experience A survey of Holtec users indicates only very minor signs of degradation of the ISFSI pad, such as minor local spalling. Based on this prior experience, the AMP is sufficient to detect aging effects.

Future Operating Experience As the ISFSI Pad inspections are performed, sites will upload information into the INPO AMID database to be shared with other users.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 90 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.3-4 Table 9.2.4 TOLLGATES Tollgate Year Assessment 1

Year of first canister loading +

25 years Evaluate information from the following sources (as available) and perform a written assessment of the aggregate impact of the information, including but not limited to trends, corrective actions required, and the effectiveness of the AMPs with which they are associated:

Results, if any, of research and development programs focused specifically on aging-related degradation mechanisms identified as potentially affecting the storage system and ISFSI site. One example of such research and development would be EPRI Chloride-Induced Stress Corrosion Cracking (CISCC) research.

Relevant results of other domestic and international research, which may include non-nuclear research Relevant domestic and international operating experience, which may include non-nuclear operating experience Relevant results of domestic and international ISFSI and dry storage system performance monitoring 2

Maximum interval of 5 years since last tollgate Evaluate additional information gained from the sources listed in Tollgate 1 along with any new relevant sources and perform a written assessment of the aggregate impact of the information. This evaluation should be informed by the results of Tollgate 1. The aging effects and mechanisms evaluated at this tollgate and the time at which it is conducted may be adjusted based on the results of the Tollgate 1 assessment.

3 Maximum interval of 5 years since last tollgate Same as Tollgate 2 as informed by the results of Tollgates 1 and 2 4

Maximum interval of 5 years since last tollgate Same as Tollgate 2 as informed by the results of Tollgates 1, 2, and 3 5

Maximum interval of 5 years since last tollgate Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, and 4 6

Maximum interval of 5 years since last tollgate Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, 4, and 5

7 Maximum interval of 5 years since last tollgate Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, 4, 5, and 6 8

Maximum interval of 5 years since last tollgate Same as Tollgate 2 as informed by the results of Tollgates 1, 2, 3, 4, 5, 6, and 7 ATTACHMENT 1 TO HOLTEC LETTER 5014914 91 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.4-1

9.4 REFERENCES

[9.0.1] U.S. Code of Federal Regulations, Title 10, "Energy", Part 72, "Licensing Requirements for the Independent Storage of Spent Nuclear Fuel and High-Level Radioactive Waste."

[9.0.2] NUREG-1536, "Standard Review Plan for Dry Cask Storage Systems",

January 1997.

[9.1.1] American Society of Mechanical Engineers, " Boiler and Pressure Vessel Code," Sections II, III, V, IX, and XI, 1995, including Addenda through 1997.

[9.1.2] U.S. Code of Federal Regulations, Title 10, "Energy", Part 71, "Packaging and Transportation of Radioactive Material.

[9.1.3] American Society for Nondestructive Testing, "Personnel Qualification and Certification in Nondestructive Testing," Recommended Practice No. SNT-TC-1A, December 1992.

[9.1.4] HI-STAR 100 Safety Analysis Report, Holtec Report No. HI-951251, current revision.

[9.1.5] American National Standards Institute, Institute for Nuclear Materials Management, "American National Standard for Radioactive Materials -

Special Lifting Devices for Shipping Containers Weighing 10,000 Pounds (4500 kilograms) or More", ANSI N14.6, September 1993.

[9.1.6] NUREG-0612, "Control of Heavy Loads at Nuclear Power Plants", U.S.

Nuclear Regulatory Commission, Washington, D.C., July 1980.

[9.1.7] U.S. Nuclear Regulatory Commission, "Fracture Toughness Criteria of Base Material for Ferritic Steel Shipping Cask Containment Vessels with a Maximum Wall Thickness of 4 Inches (0.1m)," Regulatory Guide 7.11, June 1991.

[9.1.8] U.S. Nuclear Regulatory Commission, "Fracture Toughness Criteria of Base Material for Ferritic Steel Shipping Cask Containment Vessels with a Wall Thickness Greater than 4 Inches (0.1m) But Not Exceeding 12 Inches (0.3m)," Regulatory Guide 7.12, June 1991.

[9.1.9] American National Standards Institute, Institute for Nuclear Materials Management, "American National Standard for Radioactive Materials Leakage Tests on Packages for Shipment", ANSI N14.5-1997.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 92 of 99

HI-STAR 100 FSAR Proposed Rev. 4 C (for renewal)

REPORT HI-2012610 9.4-2

[9.1.10] Holtec International Position Paper DS-213, Acceptable Flaw Size in MPC Lid-to-Shell Welds, Revision 2.

[9.2.1] Holtec International Report HI-2188306, HI-STAR 100 License Renewal Application, Latest Revision.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 93 of 99

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2188306 Proposed Rev. 1.A E-1

APPENDIX E: AGING MANAGEMENT CoC CHANGES Note that these CoC changes are shown on only Amendment 3 as an example. The same wording will need to be added to each renewed certificate amendment.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 94 of 99

NRC FORM 651 U.S. NUCLEAR REGULATORY COMMISSION (3-1999) 10 CFR 72 CERTIFICATE OF COMPLIANCE FOR SPENT FUEL STORAGE CASKS Page 1

of 34

The U.S. Nuclear Regulatory Commission is issuing this Certificate of Compliance pursuant to Title 10 of the Code of Federal Regulations, Part 72, "Licensing Requirements for Independent Storage of Spent Nuclear Fuel and High-Level Radioactive Waste" (10 CFR Part 72).

This certificate is issued in accordance with 10 CFR 72.238, certifying that the storage design and contents described below meet the applicable safety standards set forth in 10 CFR Part 72, Subpart L, and on the basis of the Final Safety Analysis Report (FSAR) of the cask design. This certificate is conditional upon fulfilling the requirements of 10 CFR Part 72, as applicable, and the conditions specified below.

Certificate No.

1008 Effective Date

10/04/99 Expiration Date

10/04/19 Docket No.

72-1008 Amendment No.

3 Amendment Effective Date

TBD Package Identification No.

USA/72-1008 Renewed Effective Date

TBD Renewed Expiration Date 10/4/59 Revision No.

0 Revision Effective Date NA Issued To: (Name/Address)

Holtec International Holtec Center One Holtec DriveBoulevard MarltonCamden, NJ 0801453 Safety Analysis Report Title

Holtec International Inc., Final Safety Analysis Report for the HI-STAR 100 Cask System Docket No. 72-1008 CONDITIONS

This certificate is conditioned upon fulfilling the requirements of 10 CFR Part 72, as applicable, the attached Appendix A (Technical Specifications) and Appendix B (Approved Contents and Design Features), and the conditions specified below:

1. CASK

The HI-STAR 100 Cask System is certified as described in the Final Safety Analysis Report (FSAR) and in NRCs Safety Evaluation Report (SER) accompanying the Certificate of Compliance. It is designed for both storage and transfer of irradiated nuclear fuel.

a.

Model No.: HI-STAR 100 (MPC-24, MPC-32, MPC-68, MPC-68F)

The HI-STAR 100 Cask System is comprised of the multi-purpose canister (MPC), which contains the fuel, and the overpack, which contains the MPC. The two digits after the MPC designate the number of reactor fuel assemblies for which the respective MPCs are designed. The MPC-24 is designed to contain up to 24 Pressurized Water Reactor (PWR) fuel assemblies. The MPC-32 is designed to contain up to 32 PWR fuel assemblies. The MPC-68 is designed to contain up to 68 Boiling Water Reactor (BWR) fuel assemblies. Any MPC-68 containing fuel assemblies with known or suspected defects, such as ruptured fuel rods, severed rods, loose fuel pellets, or which cannot be handled by normal means due to fuel cladding damage, is designated as MPC-68F.

The MPC-24, the MPC-32, and the MPC-68 (including the MPC-68F) are identical in external dimensions and will fit into the same overpack design.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 95 of 99

NRC FORM 651A (3-1999) 10 CFR 72

CERTIFICATE OF COMPLIANCE FOR SPENT FUEL STORAGE CASKS Supplemental Sheet U.S. NUCLEAR REGULATORY COMMISSION

Certificate No. 1008 Amendment No. 3

Page 2 of 43

1. b.

Description

The complete HI-STAR 100 Cask System for storage of spent nuclear fuel is comprised of two discrete components: the MPC and the storage/transport overpack. The HI-STAR 100 CASK System consists of interchangeable MPCs which constitute the confinement boundary for BWR or PWR spent nuclear fuel and an overpack which provides the helium retention boundary, gamma and neutron radiation shielding, and heat rejection capability. All MPCs have identical exterior dimensions which render them interchangeable. A single overpack design is provided which is capable of storing each type of MPC.

The HI-STAR 100 MPCs are welded cylindrical structures with flat ends. Each MPC is an assembly consisting of a honeycombed fuel basket, a baseplate, canister shell, a lid, and a closure ring. The outer diameter and cylindrical height of each MPC is fixed. However, the number of spent nuclear fuel storage locations in each of the MPCs depends on the fuel assembly characteristics. The MPC provides the confinement boundary for the stored fuel. The confinement boundary is a seal-welded enclosure constructed entirely of a stainless steel alloy.

The inner surfaces of the HI-STAR 100 overpack form an internal cylindrical cavity for housing the MPC. The outer surface of the overpack inner shell is buttressed with intermediate shells of gamma shielding.

The fuel transfer and auxiliary equipment necessary for Independent Spent Fuel Storage Installation operation are not included as part of the HI-STAR 100 Cask System reviewed for a Certificate of Compliance under 10 CFR Part 72, Subpart L. Such equipment may include, but is not limited to, special lifting devices, transfer trailers or equipment, and vacuum drying/helium leak test equipment.

2. OPERATING PROCEDURES

Written operating procedures shall be prepared for cask handling, loading, movement, surveillance, and maintenance. The users site-specific written operating procedures shall be consistent with the technical basis described in Chapter 8 of the SAR.

3. ACCEPTANCE TESTS AND MAINTENANCE PROGRAM

Written cask acceptance tests and maintenance program shall be prepared consistent with the technical basis described in Chapter 9 of the SAR.

4. QUALITY ASSURANCE

Activities in the areas of design, procurement, fabrication, assembly, inspection, testing, operation, maintenance, repair, modification of structures, systems and components, and decommissioning that are important to safety shall be conducted in accordance with a Commission-approved quality assurance program which satisfies the applicable requirements of 10 CFR Part 72, Subpart G, and which is established, maintained, and executed with regard to the cask system.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 96 of 99

NRC FORM 651A (3-1999) 10 CFR 72

CERTIFICATE OF COMPLIANCE FOR SPENT FUEL STORAGE CASKS Supplemental Sheet U.S. NUCLEAR REGULATORY COMMISSION

Certificate No. 1008 Amendment No. 3

Page 3 of 34

5. HEAVY LOADS REQUIREMENTS

Each lift of a HI-STAR 100 spent fuel cask must be made in accordance with the existing heavy loads requirements and procedures of the licensed facility in which the lift is made. A plant-specific safety review (in accordance with 10 CFR 50.59 or 10 CFR 72.48, if applicable) is required to show operational compliance with existing plant-specific heavy loads requirements.

6. APPROVED CONTENTS

Contents of the HI-STAR 100 Cask System must meet the fuel specifications given in Appendix B to this certificate.

7. APPROVED DESIGN FEATURES

Features or characteristics for the site or cask must be in accordance with Appendix B to this certificate.

8. CHANGES TO THE CERTIFICATE OF COMPLIANCE

The holder of this certificate who desires to make changes to the certificate, which includes Appendix A (Technical Specifications) and Appendix B (Approved Contents and Design Features), shall submit an application for amendment of the certificate.

9. AUTHORIZATION

The HI-STAR 100 Cask System, which is authorized by this certificate, is hereby approved for general use by holders of 10 CFR Part 50 licenses for nuclear reactors at reactor sites under the general license issued pursuant to 10 CFR 72.210, subject to the conditions specified by 10 CFR 72.212, and the attached Appendix A and Appendix B.

10. FSAR UPDATE FOR RENEWED COC The CoC holder shall submit an updated FSAR to the Commission, in accordance with 10 CFR 72.4, within 90 days of the effective date of the renewal. The updated FSAR shall reflect the changes and CoC holder commitments resulting from the review and approval of the renewal of the CoC. The CoC holder shall continue to update the FSAR pursuant to the requirements of 10 CFR 72.248.
11. 72.212 EVALUATIONS FOR RENEWED COC USE Any general licensee that initiates spent fuel dry storage operations with the HI-STAR 100 system after the effective date of the renewal of the CoC and any general licensee operating a HI-STAR 100 system as of the effective date of the renewal of the CoC, including those that put additional storage systems into service after that date, shall:
a. as part of the evaluations required by 10CFR72.212(b)(5), include the evaluations related to the terms, conditions, and specifications of this CoC amendment as modified (i.e., changed or added) as a result of the renewal of the CoC;
b. as part of the document review required by 10CFR72.212(b)(6), include a review of the FSAR changes resulting from the renewal of the CoC; and ATTACHMENT 1 TO HOLTEC LETTER 5014914 97 of 99

NRC FORM 651A U.S. NUCLEAR REGULATORY COMMISSION (3-1999) 10 CFR 72 CERTIFICATE OF COMPLIANCE FOR Certificate No. 1008 SPENT FUEL STORAGE CASKS Amendment No. 3 Supplemental Sheet Page 4

of 4

c. ensure that the evaluations required by 10CFR72.212(b)(7) and (8) capture the evaluations and review described in (a.) and (b.) of this CoC condition.
12. AMENDMENTS AND REVISIONS FOR RENEWED COC All future amendments and revisions to this CoC shall include evaluations of the impacts to aging management activities (i.e. time-limited aging analyses and aging management programs) to assure they remain adequate for any changes to SSCs within the scope of renewal.

FOR THE U. S. NUCLEAR REGULATORY COMMISSION Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards

Attachments:

1. Appendix A
2. Appendix B ATTACHMENT 1 TO HOLTEC LETTER 5014914 98 of 99

Certificate of Compliance No. 1008 Appendix A Renewed Amendment 3 3-2 Programs 3.0

3.0 ADMINISTRATIVE CONTROLS AND PROGRAMS

The following programs shall be established, implemented, and maintained.

3.1 Deleted

3.2 Deleted

3.3 Deleted

3.4.

Radioactive Effluent Control Program

This program implements the requirements of 10 CFR 72.44(d).

a.

The HI-STAR 100 Cask System does not create any radioactive materials or have any radioactive waste treatment systems. Therefore, specific operating procedures for the control of radioactive effluents are not required. Specification 2.1.1, Multi-Purpose Canister (MPC), provides assurance that there are no radioactive effluents from the SFSC.

b.

This program includes an environmental monitoring program. Each general license user may incorporate SFSC operations into their environmental monitoring program for 10 CFR Part 50 operations.

c.

An annual report shall be submitted pursuant to 10 CFR 72.44(d)(3).

3.5 Aging Management Program Procedures and Reporting Each general licensee shall have a program to establish, implement, and maintain written procedures for each AMP described in the FSAR. The program shall include provisions for changing AMP elements, as necessary, and within the limitations of the approved licensing bases to address new information on aging effects based on inspection findings and/or industry operating experience provided to the general licensee during the renewal period.

The general licensee shall establish and implement these written procedures within 365 days of the effective date of the renewal of the CoC or 365 days of the 20th anniversary of the loading of the first dry storage system at its site, whichever is later.

Each general licensee shall perform tollgate assessments as described in Chapter 9 of the FSAR.

ATTACHMENT 1 TO HOLTEC LETTER 5014914 99 of 99