MONTHYEARML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18134A1102018-05-15015 May 2018 Letter to J. Bondre Acceptance Review of Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 1 to NUHOMS Eos System (Docket No. 72-1042, CAC No. 001028, EPID: L-2018-LLA-0043) - Request for Supplemental Informa Project stage: Acceptance Review ML18134A1112018-05-15015 May 2018 Enclosure 1: Rsi (Non-Proprietary) (Letter to J. Bondre Acceptance Review of Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 1 to NUHOMS Eos System (Docket No. 72-1042, CAC No. 001028, EPID: L-2018-LLA-0043 Project stage: Acceptance Review ML18179A1042018-06-15015 June 2018 Attachment 1 - Summary of Proposed Changes - LAR 1032-5 Project stage: Request ML18213A0372018-08-0101 August 2018 Letter to P. Narayanan Acceptance Review (Continued) of Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 1 to NUHOMS Eos System (Docket No. 72-1042, CAC No. 001028, EPID: L-2018-LLA-0043) - Request for Suppl Project stage: Acceptance Review ML18213A0382018-08-0101 August 2018 Enclosursi (Letter to P. Narayanan Acceptance Review (Continued) of Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 1 to NUHOMS Eos System (Docket No. 72-1042, CAC No. 001028, EPID: L-2018-LLA-0043) Project stage: Acceptance Review ML18268A1392018-09-20020 September 2018 Modification to Requested Changes on HI-STORM FW Amendment 5 Request Project stage: Request ML18355A8642018-12-21021 December 2018 Enclosure 1 - RAI (Non-Proprietary) (Letter to P. Narayanan Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 1, to NUHOMS Eos System (Docket No. 72-1042, CAC No. 001028, EPID: L-2018-LLA-0043) - Request for Project stage: RAI ML18355A8632018-12-21021 December 2018 Letter to P. Narayanan Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 1, to NUHOMS Eos System (Docket No. 72-1042, CAC No. 001028, EPID: L-2018-LLA-0043) - Request for Additional Information Project stage: RAI ML19046A0642019-02-13013 February 2019 Letter to J. Tomlinson Acceptance Review of Request for Amendment No. 5 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Cask System (W/Enclosure) Project stage: Acceptance Review ML19092A1722019-03-20020 March 2019 Attachment 1 - HI-STORM 100 Amendment 15 Summary of Proposed Changes Project stage: Request ML19178A1232019-06-28028 June 2019 Letter to P. Narayanan Acceptance Review of Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 2 NUHOMS Eos System (Dkt: 72-1042, CAC: 001028, EPID: L-2019-LLA-0078) Request for Supplemental Information Project stage: Acceptance Review ML19178A1242019-06-28028 June 2019 Enclosure 1: Rsi (non-proprietary) (Letter to P. Narayanan Acceptance Review of Tn Americas LLC Application for Certificate of Compliance No. 1042, Amendment No. 2 NUHOMS Eos System (Dkt: 72-1042, CAC: 001028, EPID: L-2019-LLA-0078)) Project stage: Acceptance Review ML19182A0602019-07-0909 July 2019 Letter to J. Tomlinson Acceptance Review of Request for Amendment No. 15 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System - Request for Supplemental Information (W/Enclosure) Project stage: Acceptance Review ML19247B7182019-09-0303 September 2019 Letter to J. Tomlinson Amendment No. 5 to Certificate of Compliance No. 1023 for the HI-STORM Flood/Wind Multipurpose Canister Storage System - Request for Additional Information (W/Enclosure 1) Project stage: RAI ML19277H0352019-09-16016 September 2019 HI-STORM 100 Amendment 15 - Responses to Requests for Supplemental Information Project stage: Request ML19277G8022019-09-16016 September 2019 Attachment 1: HI-STORM 100 Amendment 15 - Request for Supplemental Information Responses Project stage: Request ML19294A1362019-10-18018 October 2019 Acceptance Letter for HI-STORM 100 Amendment No. 15 Project stage: Acceptance Review ML19158A2722019-12-20020 December 2019 Memorandum to J. Cai User Need for Rulemaking for the Holtec HI-STORM Flood-Wind Multipurpose Canister Storage System, Amendment No. 4 Project stage: Other ML19158A2752019-12-20020 December 2019 Enclosure 3: Proposed CoC 1032 Amendment No. 4 Appendix B (Memorandum to J. Cai User Need for Rule Making for the Holtec HI-STORM Flood-Wind Multipurpose Canister Storage System, Amendment No. 4) Project stage: Other ML19158A2762019-12-20020 December 2019 Enclosure 4: Preliminary CoC 1032 Amendment No. 4 SER (Memorandum to J. Cai User Need for Rule Making for the Holtec HI-STORM Flood-Wind Multipurpose Canister Storage System, Amendment No. 4) Project stage: Other ML19158A2732019-12-20020 December 2019 Enclosure 1: Proposed CoC 1032 Amendment No. 4 (Memorandum to J. Cai User Need for Rule Making for the Holtec HI-STORM Flood-Wind Multipurpose Canister Storage System, Amendment No. 4) Project stage: Other ML19158A2742019-12-20020 December 2019 Enclosure 2: Proposed CoC 1032 Amendment No. 4 Appendix a (Memorandum to J. Cai User Need for Rule Making for the Holtec HI-STORM Flood-Wind Multipurpose Canister Storage System, Amendment No. 4) Project stage: Other ML20065L3442020-03-0606 March 2020 Amendment No. 15 to Certificate of Compliance No. 1014 for the Hi-Storm 100 Multipurpose Canister Storage System - Request for Additional Information Project stage: RAI ML20128J2922020-04-27027 April 2020, 28 April 2020 International, Submittal of Responses to Nrc,S 1st Round RAIs for HI-STORM 100 Amendment Number 15 Project stage: Request ML20128J2932020-04-28028 April 2020 International, Submittal of Responses to Nrc,S 1st Round RAIs for HI-STORM 100 Amendment Number 15 Project stage: Request ML20136A4752020-05-15015 May 2020 Holtec International Submittal of Responses to Nrc'S RAIs 3-1 and 3-6 for HI-STORM 100 Amendment Number 15 Project stage: Request ML20164A2942020-06-12012 June 2020 International Submittal of Supplemental Information to RAI 8-1 Response for HI-STORM 100 Amendment Number 15 Project stage: Request ML20205L5022020-08-0404 August 2020 Amendment No. 15 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System - Second Request for Additional Information Project stage: RAI ML20238B9872020-08-24024 August 2020 Approval of Holtec International Request for Withholding Information from Public Disclosure - Certificate of Compliance No. 1014, HI-STORM 100 Multipurpose Canister Storage System, Amendment No. 15 Project stage: Withholding Request Acceptance ML20245E4632020-09-0101 September 2020 International - Submittal of Supplemental Information on HI-STORM 100 Amendment 15 Project stage: Request ML20269A4252020-09-25025 September 2020 International - Submittal of Supplemental Information on HI-STORM 100 Amendment 15 Project stage: Request ML20318A3212020-11-13013 November 2020 Submittal of Clarification RAI Responses on HI-STAR 100 License Renewal Project stage: Request ML20329A3232020-11-24024 November 2020 International, Clarification RAI Responses on HI-STAR 100 License Renewal Updated Project stage: Other ML20295A4222021-01-27027 January 2021 Preliminary CoC 1014 Amendment No. 15 Safety Evaluation Report Project stage: Approval ML20295A4202021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 Appendix A-100U Project stage: Other ML20295A4152021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 for Holtec Intl Project stage: Other ML20295A4182021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 Appendix C Project stage: Other ML20295A4162021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 Appendix a Project stage: Other ML20295A4192021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 Appendix D Project stage: Other ML20295A4212021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 Appendix B-100U Project stage: Other ML20295A4132021-01-27027 January 2021 User Need for Rulemaking for the Holtec HI-STORM 100 Cask System, Amendment No. 15 Project stage: Other ML20295A4172021-01-27027 January 2021 Proposed CoC 1014 Amendment No. 15 Appendix B Project stage: Other ML21068A3612021-03-0909 March 2021 International, Submittal of HI-STORM 100 Multipurpose Canister Storage System Amendment 16 Request Project stage: Request ML21118A8692021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15, Appendix A-100U Technical Specifications for the Hi-Storm 100 Cask System (Model N. 100U Addition) Project stage: Other ML21118A8672021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15, Appendix C, Technical Specifications for the Hi-Storm 100S Version E Cask Project stage: Other ML21118A8642021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15 Project stage: Other ML21118A8712021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15. Final Safety Evaluation Report Project stage: Approval ML21118A8682021-05-13013 May 2021 Certificate of Compliance 1014 - Amendment No. 15, Appendix D, Approved Contents and Design Features for the Hi-Storm 100S Version E Cask and Hi-Trac Ms Project stage: Other 2019-09-03
[Table View] |
Text
Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5014896 Page 1 of 2 April 28, 2020 Yen-Ju Chen Sr. Project Manager - Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 72-1014, Certificate of Compliance (CoC) No. 1014
Subject:
Submittal of Responses to NRCs 1st Round RAIs for HI-STORM 100 Amendment Number 15 Reference(s): [1] Amendment No. 15 to Certificate of Compliance No. 1014 for the HI-STORM 100 Multipurpose Canister Storage System - Request for Additional Information (Letter from Yen-Ju Chen (NRC) to Joyce Tomlinson (Holtec) dated March 6, 2020)
Dear Ms. Chen:
By letter dated March 6, 2020 [1], NRC staff requested additional information (RAIs) needed to complete their detailed technical review of HI-STORM 100 Amendment 15 to the Certificate of Compliance No. 1014.
Attachments 1 and 2 to this letter contains the responses to all of the RAIs except RAI 3-1, 3-6 and 4-9, in proprietary and non-proprietary versions. Attachment 3 contains the proposed changes to the CoC not related to the RAIs, as previously discussed. Attachments 4, 5 and 13 contain changes to the CoC Appendix C, Appendix D and Appendix A, respectively. Attachments 6 and 7 contain the proposed FSAR changed pages in proprietary and non-proprietary versions. Both the CoC and the FSAR utilize track changes and yellow highlighting to identify the changes specific to these RAI responses, to differentiate them from track changes used for the original submittal and RSI response. Attachments 8 through 11 contain proprietary technical information required to support the responses. Attachment 12 contains an affidavit prepared in accordance with 10 CFR 2.390 requesting that the proprietary attachments be withheld from public disclosure.
If you have any questions, please contact me at 856-797-0900 ext. 3765.
Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5014896 Page 2 of 2 Sincerely, Joyce Tomlinson Adjunct Licensing Manager, Holtec International cc:
(via email)
Andrea Kock (USNRC)
John McKirgan (USNRC)
Attachments:
- Responses to Requests for Additional Information (RAIs) for HI-STORM 100 LAR 1014-14 (proprietary) : Responses to Requests for Additional Information (RAIs) for HI-STORM 100 LAR 1014-14 (non-proprietary) : HI-STORM 100 CoC No. 1014 Revision 15 (non-proprietary) : HI-STORM 100 CoC Appendix C Proposed Changed pages (non-proprietary) : HI-STORM 100 CoC Appendix D Proposed Changed pages (non-proprietary) : HI-STORM 100 FSAR Proposed Changed pages (Proposed Rev. 17.B)
(proprietary) : HI-STORM 100 FSAR Proposed Changed pages (Proposed Rev. 17.B) (non-proprietary) : HI-2043317R40, HI-STORM Thermal-Hydraulic Analyses Supporting Upto 36.9 KW High Heat Load Amendment (proprietary) : HI-2104790R3, Nuclear Group computer Code Benchmark Calculations (proprietary) 0: HI-2012771R29, HI-STAR 100 and HI-STORM 100 Additional Criticality Calculations (proprietary) 1: HI-2033039R6, Critical Experiment Benchmark (proprietary) 2: Affidavit Pursuant to 10 CFR 2.390 to Withhold Information from Public Disclosure 3: HI-STORM 100 CoC Appendix A Proposed Changed pages (non-proprietary)