Text
e e
VIRGINIA ELECTRIC AND PowER COMPANY RICHMOND, VIRGINIA 23261 October 11, 1991 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 NORTH ANNA POWER STATION UNITS 1 AND 2 EMERGENCY RESPONSE DATA SYSTEM DATA BASE UPDATES Serial No.
NL&P/CGL Docket Nos.
License Nos.90-681 E RO 50-280 50-281 50-338 50-339 DPR-32 DPR-37 NPF-4 NPF-7 An October 25, 1990 N RC letter requested detailed hardware, communications, data point, and administrative information to assist the N_RC's contractor in designing Emergency Response Data System (EROS) interfaces. In.letters dated April 11, 1991 and June 6, 1991 (Serial Nos.90-681 B and 90-681 C, respectively), Virginia Electric and Power Company provided the requested information for Surry and North Anna Power Stations.
We successfully completed preliminary testing of the EROS data links and software for both Surry and North Anna earlier this month. The preliminary testing was performed with NUS in Idaho using a computer system that emulates the behavior of the NRC EROS computer in Bethesda. As a result of the preliminary testing, one data base point per unit for Surry required minor changes. These changes are detailed in the Data Point Library (DPL) Change Reports included in Attachment 1.
Previous transmittals have provided OPL Change Reports for both Surry and North Anna.
In order to ensure that the NRC, NUS, and Virginia Electric and Power Company are referencing the same set of OPLs, updated OPL forms for North Anna Units 1 and 2 and Surry Units 1 and 2 are included in Attachments 2, 3, 4, and 5, respectively. It should be noted that the way the OPLs are sorted has been changed such that they are now printed in alphabetical order by the field titled "NRC EROS PARAMETER." This change should improve the NRC's ability to reference the printed version of the OPLs.
e The updated data base files, documented in Attachments 2 through 5, are also provided in the dBase IV format on Attachment 6. The dBase IV files contained on are as follows:
File Name NA1_ERDS.DBF NA1_ERDS.DBT NA2_ERDS. DBF NA2_ERDS.DBT SU1_ERDS.DBF SU1_ERDS.DBT SU2 ERDS.DBF SU2 ERDS.DBT Description North Anna Unit 1 DPL dBase file.
North Anna Unit 1 dBase memo file for DPL unique system description field.
North Anna Unit 2 DPL dBase file.
North Anna Unit 2 dBase memo file for DPL unique system description field.
Surry Unit 1 DPL dBase file.
Surry Unit 1 dBase memo file for DPL unique system description field.
Surry Unit 2 DPL dBase file.
Surry Unit 2 dBase memo file for DPL unique system description field.
If you have questions regarding this information, please contact us.
Very truly yours, IJLc;~
W. L. Stewart Senior Vice President - Nuclear Attachments
- 1.
DPL Change Reports for Surry Units 1 and 2
- 2.
Updated DPL Forms for North Anna Unit 1
- 3.
Updated DPL Forms for North Anna Unit 2
- 4.
Updated DPL Forms for Surry Unit 1
- 5.
Updated DPL Forms for Surry Unit 2
- 6.
Updated DPL Data Base Files in dBase IV Format
cc:
U. S. Nuclear Regulatory Commission - Attachments 1 - 5 Region II 101 Marietta Street, N. W.
Suite 2900 Atlanta, Georgia 30323 Mr. M. W. Branch - Attachments 1 - 5 NRC Senior Resident Inspector Surry Power Station Mr. M. S. Lesser - Attachments 1 - 5 NRC Senior Resident Inspector North Anna Power Station NUS Corporation / El Division - Attachments 1 - 6 P. 0. Box 50736 Idaho Falls, Idaho 83405 Attention: Mr. Tony LaRosa
EMERGENCY RESPONSE DATA SYSTEM DATA BASE UPDATES REC'D W/LTR OTO 10/lli91.... 9110180052
-NOTICE-THE ATTACHED FILES ARE OFFICIAL RECORDS OF THE INFORMATION &
REPORTS MANAGEMENT BRANCH.
THEY HAVE BEEN CHARGED TO YOU.
FOR A LIMITED TIME PERIOD AND MUST BE RETURNED TO THE RE-CORDS & ARCHIVES SERVICES SEC-TION P1-22WHITE FLINT. PLEASE DO.
NOT SEND DOCUMENTS CHARGED OUT THROUGH THE MAIL. REMOVAL OF ANY PAGE(S) FROM DOCUMENT FOR REPRODUCTION MUST BE RE-FERRED TQ*FILE PERSONNEL.
-NOTICE-
ATTACHMENT 1 SURRY DPL CHANGE REPORTS
,1 Page No.
1 STATION: Surry UNIT: 1 PRINTED 09/05/91 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT M3MM001A AT 10: 42 ON 09/05/91.
CHANGES WERE AS FOLLOWS:*
DATE:
NRC ERDS PARAMETER:
GENERIC/COND DESC:
WAS: 05/20/91 IS: 09/05/91 WAS: STAB CLASS IS: WIND SPEED WAS: AIR STABILITY AT REACTOR SITE IS: W 0IND SPEED AT REACTOR SITE
- .a,-... -
Page No.
1 STATION: Surry UNIT: 2 PRINTED 09/05/91 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT M3MM001A AT 10:42 ON 09/05/91.
CHANGES WERE AS FOLLOWS:
DATE:
NRC EROS PARAMETER:
GENERIC/COND DESC:
WAS: 05/20/91 IS: 09/05/91 WAS: STAB CLASS IS: WIND SPEED WAS: AIR STABILITY AT REACTOR SITE IS: WIND SPEED AT REACTOR SITE
ATTACHMENT 4 SURRY UNIT 1 DPL'S
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
07/01/91 SU1 N/A AX FD FL 1/A F1 FW001A STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE SG A AFW FLOW (RD)
STM GEN A AUX FEEDWATER FLOW A
GPM 0 - 394 11 H20 0.0 350.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT AUX FEED PMP DISCH UPSTRM OF STM GEN A VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses auxiliary feedwater flow to steam generator A.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\J PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE 07/01/91 SU1 N/A AX FD FL 2/B F1FW002A SG B AFW FLO\\J (WT)
STM GEN B AUX FEED\\JATER FLO\\J A
GPM 0 - 394 11 H20 0.0 350.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT AUX FEED PMP DISCH UPSTRM OF STM GEN B VARIABLE NI DETECTOR PO\\JER SUPPLY CUT-OFF PO\\JER LEVEL:
N/A NI DETECTOR PO\\JER SUPPLY TURN-ON PO\\JER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses auxiliary feedwater flow to steam generator B.
PR l NTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
07/01/91 SU1 N/A AX FD FL 3/C F1FW003A STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
STM GEN C AUX FEEDUATER FLOW A
GPM 0 - 394 11 H20 MINIMUM INSTR RANGE:
0.0 MAXIMUM INSTR RANGE:
350.0 ZERO POINT
REFERENCE:
N/A REFERENCE POINT NOTES:
N/A PROC OR SENS:
S NUMBER OF SENSORS:
N/A HOU PROCESSED:
N/A - THIS IS A DIRECT SENSOR INPUT SENSOR LOCATIONS:
AUX FEED PMP DISCH UPSTRM OF STM GEN C ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR POUER SUPPLY CUT-OFF POUER LEVEL:
N/A NI DETECTOR POUER SUPPLY TURN-ON POUER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses auxiliary feedwater flow to steam generator C.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A BWST LEVEL L1CS001C RWST LEVEL STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE BORATED WATER STORAGE TANK LEVEL A
PCT 1 % = 3997 GALLONS 0.0 100.0 TNKBOT 13500 GALLONS REMAIN AT ZERO POINT p
4 MINUMUM
- SEE SYSTEM DESCRIPTION RWST VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
DRY Indicates the level in the R~ST.
The lowest valid signal is used.
If none of the 4 signals is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
05/20/91 SU1 N/A CL TEMP 1/A T1RC004A STATION: Surry UNIT: 1 P\\.IR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
LOOP A \\.IR T COLD (RD)<>
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\.I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STM GEN A OUTLET TEMPERATURE A
DEGF N/A 0.0 700.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT LOOP A COLD LEG VARIABLE NI DETECTOR PO\\.IER SUPPLY CUT-OFF PO\\.IER LEVEL:
N/A NI DETECTOR PO\\.IER SUPPLY TURN-ON PO\\.IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses loop A cold leg temperature
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOIJ PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A CL TEMP 2/B T1RC008A STATION: Surry UNIT: 1 Pl.JR DATA POINT LIBRARY REFERENCE FILE LOOP BI.JR T COLD (IJT) <>
STM GEN B OUTLET TEMPERATURE A
DEGF N/A 0.0 700.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT LOOP B COLD LEG VARIABLE NI DETECTOR POIJER SUPPLY CUT-OFF POIJER LEVEL:
N/A NI DETECTOR POIJER SUPPLY TURN-ON POIJER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses loop B cold leg temperature.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT OESC:
GENERIC/CONO DESC:
ANALOG/DIGITAL:
ENGR U~ITS/OIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO'.I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A CL TEMP 3/C T1RC012A STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE LOOP C WR T COLD (BL) <>
STM GEN C OUTLET TEMPERATURE A
DEGF N/A 0.0 700.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT LOOP C COLD LEG VARIABLE NI DETECTOR PO'.IER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR PO'.IER SUPPLY TURN-ON PO'.IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM OESC:
Senses loop C cold leg t~rature.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A CNTMNT RAD R1RM207C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CNTMT AIR GASEOUS (160)
RADIATION LEVEL IN CONTAINMENT A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG, 45 1 10" LEVEL WEST END VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Continuously monitors the radiation level of air taken from the reactor containment *..
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A CNTMNT RAD R1RM208C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CNTMT AIR PART (159)
RADIATION LEVEL IN CONTAINMENT A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG, 45' 10 11 LEVEL WEST END VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Continuously monitors the radiation level of particles in the air taken out of the reactor containment
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A CNTMNT RAD R1RM209C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CNTMT AREA (163)
RADIATION LEVEL IN CONTAINMENT A
MR/HR N/A 1.0E-1 1.0E?
N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CONTAINMENT, INSIDE CRANE WALL VARIABLE NI DETECTOR PO\\.IER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level within the reactor containment.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A CNTMNT RAD R1RM210C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CNTMT PER HATCH (161)
RADIATION LEVEL IN CONTAINMENT A
MR/HR N/A 1.OE-1 1.OE7 N/A N/A p
EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG, OUTSIDE PERSONNEL HATCH VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level in the Personnel Hatch area.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\.I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A CNTMNT RAD R1RM213C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT HR AREA (127)
RADIATION LEVEL IN CONTAINMENT A
R/HR N/A 3.162E-1 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CONTAINMENT, INSIDE CRANE WALL 47' LEVEL VARIABLE NI DETECTOR POlolER SUPPLY CUT-OFF POlolER LEVEL:
N/A NI DETECTOR POlolER SUPPLY TURN-ON POlolER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the reactor containment -
HIGH RANGE.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A CNTMNT RAD R1RM214C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT HR AREA (128)
RADIATION LEVEL IN CONTAINMENT A
R/HR N/A 1.0 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CONTAINMENT, INSIDE CRANE WALL 47' LEVEL VARIABLE NI DETECTOR POWER SUPPLY CUT*OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the reactor containment HIGH RANGE.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOIJ PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A COND A/E RAD R1RM217C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CONDENSER AE (111)
COND AIR EJECTOR RADIOACTIVITY A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG MEZZANINE OVERHEAD BY AE VARIABLE NI DETECTOR PO\\JER SUPPLY CUT-OFF PO\\JER LEVEL:
N/A NI DETECTOR PO\\JER SUPPLY TURN-ON PO\\JER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Continuously monitors the gaseous effluent from the condenser air ejectors.
On high radiation any radioactive air is diverted into the reactor containment
- PRINTED 09/05/91
~--------
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOIJ PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POIJER SUPPLY CUT-OFF POIJER LEVEL:
05/20/91 SU1 N/A CORE FLO\\./
F1RC004C STATION: Surry UNIT: 1 P\\.IR DATA POINT LIBRARY REFERENCE F.ILE AVERAGE RCS LOOP FLO\\./
TOTAL REACTOR FLO\\./
A PCT 0 - 460" H20 0.0 120.0 N/A N/A p
9 AVERAGE - SEE SYSTEM DESCRIPTION STM GEN DISCHARGE UPSTRM OF RCP VARIABLE N/A NI DETECTOR POIJER SUPPLY TURN-ON POIJER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the flow of coolant from the steam generator to the reactor coolant~-
The average of the 3 loop calculated average flows is used for this point.
The 3 loop average values are calculated by taking the average of the valid flow signals for each loop.
If all loop flow signals are valid, 3 flow readings will be used for each loop.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/0 I GIT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO',I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A CTMNT PRESS P1LM001C STATION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE CONTAINMENT PRESSURE CONTAINMENT PRESSURE A
PSIA N/A 0.0 180.0 N/A N/A p
4 AVERAGE* SEE SYSTEM DESCRIPTION CABLE PENETRATION AREA IN AUX BLDG VARIABLE NI DETECTOR PO',IER SUPPLY CUT-OFF PQ',IER LEVEL:
N/A NI DETECTOR PQ',IER SUPPLY TURN-ON PQ',IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE CCJ4PENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Senses reactor contairvnent pressure.
The valid intermediate range signals (4 signals if all are valid) are averaged.
If no intermediate range signals are valid, the average of the wide range signals is used (2 signals if all are valid).
If no signals are valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/0 I GIT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A CTMNT SMP NR L1DA002C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT NR SUMP LEVEL CONTAINMENT SUMP NR LEVEL A
INCH 1 IN= 2369 GALLONS 4.5 26.5 TNKBOT 280 GALLONS REMAIN AT ZERO POINT p
2 MAXIMUM* SEE SYSTEM DESCRIPTION CONTAINMENT SUMP VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE HOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Senses reactor containments~ level and provides a high level alarm.
The largest valid narrow range signal is used for this point.
If all signals are valid, 2 signals are considered.
If both signals are invalid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR PCNER SUPPLY CUT-OFF PCNER LEVEL:
05/20/91 SU1 N/A CTMNT SMP WR L1DA001C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT WR SUMP LEVEL CONTAINMENT SUMP WR LEVEL A
FT 1 FT= 58343 GALLONS 0.43 9.0 TNKBOT N/A p
2 AVERAGE* SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A NI DETECTOR PCNER SUPPLY TURN-ON PCNER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE Cc>>IPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A The valid wide range signals are averaged (2 signals if all are valid).
If neither signal is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLAN~ SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL~
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU1 N/A CTMNT TEMP T1LM001C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFER~NCE FILE CONTAINMENT TEMPERATURE CONTAINMENT TEMPERATURE A
DEGF N/A 50.0 300.0 N/A N/A p
2 AVERAGE* SEE SYSTEM DESCRIPTION REACTOR CONTAINMENT VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Senses reactor contairment tenl)erature.
The valid signals are averaged (2 signals if all are valid).
If neither signal is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF GAS RAD R1RM203C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE AFPT EXHAUST (129)
RADIOACTIVITY OF RELEASED GASES A
MR/HR N/A
- 1. OE-2 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SAFEGUARDS AREA, OUTSIDE WALL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of the unit 1 turbine-driven auxiliary feed ~
exhaust ("Terry" turbine)
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF GAS RAD R3RM203C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE PROCESS VENT GAS (102)
RADIOACTIVITY OF RELEASED GASES A
CPM N/A 10.0 1.OE6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG 45' 10" LEVEL WEST END VARIABLE NI DETECTOR PO\\IER SUPPLY CUT*OFF PO\\IER LEVEL:
N/A NI DETECTOR PO\\IER SUPPLY TURN*ON PO\\IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE Cc>>4PENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of air taken from the process vent
- PRINTED 09/05/91
--- ------ -- --- ~
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
05/20/91 su, N/A EFF GAS RAD R3RM204C STATION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
PV HIGH RANGE (130-2)
RADIOACTIVITY OF RELEASED GASES A
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
UCI/CC N/A 1.OE-3 1.OE5 N/A N/A p,
EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level in the process vent - HIGH RANGE
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOii PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF GAS RAD R3RM205C STATION: Surry UN IT: 1 PIIR DATA POINT LIBRARY REFERENCE FILE PV HIGH RANGE (130-2)
RADIOACTIVITY OF RELEASED GASES A
UCI/S N/A 1.0E4 1.0E12 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the process vent - HIGH RANGE
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOl,I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF GAS RAD R3RM206C STAT ION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE PV NORMAL (130-1)
RADIOACTIVITY OF RELEASED GASES A
UCI/CC N/A 1.0E-8 1.0 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE NI DETECTOR PCll,IER SUPPLY CUT-OFF P()l,IER LEVEL:
N/A NI DETECTOR PCll,IER SUPPLY TURN-ON P()l,IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the process vent - NORMAL RANGE.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOIJ PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF GAS RAD R3RM207C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE PV NORMAL (130-1)
RADIOACTIVITY OF RELEASED GASES A
UCI/S N/A i.O 1.0E8 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE NI DETECTOR POIJER SUPPLY CUT-OFF POIJER LEVEL:
N/A NI DETECTOR POIJER SUPPLY TURN-ON POIJER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the process vent - NORMAL RANGE
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
05/20/91 SU1 N/A EFF GAS RAD R3RM208C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
PV PARTICULATE (101)
RADIOACTIVITY OF RELEASED GASES A
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG 45 1 10 11 LEVEL WEST END VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level of particles in the air taken out of the process vent.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\.I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF GAS RAD R3RM219C STATION: Surry UNIT: 1 P\\.IR DATA POINT LIBRARY REFERENCE FILE VENT VENT GASEOUS (110)
RADIOACTIVITY OF RELEASED GASES A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG 45 1 10 11 LEVEL EAST END VARIABLE NI DETECTOR PO\\.IER SUPPLY CUT-OFF PO'wER LEVEL:
N/A NI DETECTOR PO'wER SUPPLY TURN-ON PO\\.IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of air taken from ventilation vent stack #2.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT OESC:
GENERIC/CONO OESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\J PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR PO'.IER SUPPLY CUT-OFF PO'.IER LEVEL:
05/20/91 SU1 N/A EFF GAS RAD R3RM220C ST A Tl ON: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE VV PARTICULATE (109)
RADIOACTIVITY OF RELEASED GASES A
CPM N/A 10.0 1.OE6 N/A N/A p,
EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLOG 45 1 10 11 LEVEL EAST ENO VARIABLE N/A NI DETECTOR PO'.IER SUPPLY TURN-ON PO'.IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM OESC:
N/A Monitors the radiation level of particles in the air taken from ventilation vent stack #2
- PRINTED 09/05/91
DATE:
REACTOR UN IT :
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF GAS RAD R3RM221C STAT ION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE VV 1 GAS RAD MON (104)
RADIOACTIVITY OF RELEASED GASES A
CPM N/A 10.0 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT UNIT 2 SWITCHGEAR ROOM (NORTH WALL)
VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON PO~ER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LE1/0::L REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of air taken from the ventilation vent
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOI.I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF GAS RAD R3RM223C STATION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE VV HIGH RANGE (131-2)
RADIOACTIVITY OF RELEASED GASES A
UCI/CC N/A 1.0E-3 1.0E5 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE NI DETECTOR PCJ\\,IER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR PQ\\,IER SUPPLY TURN-ON PQ\\,IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of ventilation vent stack #2 -
HIGH RANGE
- PRINTED 09/05/91
---------=-=====-=-:...__,=--------=--- -
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOIJ PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POIJER SUPPLY CUT-OFF POIJER LEVEL:
05/20/91 SU1 N/A EFF GAS RAD R3RM224C STATION: Surry UNIT: 1 PIJR DATA POINT LIBRARY REFERENCE FlLE VV HIGH RANGE (131-2)
RADIOACTIVITY OF RELEASED GASES A
UCI/S N/A 1.0E4 1.0E12 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE N/A NI DETECTOR PO'JER SUPPLY TURN-ON POIJER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of ventilation vent stack #2 -
HIGH RANGE
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF GAS RAD R3RM225C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE VV NORMAL RANGE (131-1)
RADIOACTIVITY OF RELEASED GASES A
UCI/CC N/A 1.OE-8 1.0 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of ventilation vent stack #2 -
NORMAL RANGE.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOI.I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF GAS RAD R3RM226C STATION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE VV NORMAL RANGE (131-1)
RADIOACTIVITY OF RELEASED GASES A
UCI/S N/A 1.0 1.0E8 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE NI DETECTOR POI.IER SUPPLY CUT-OFF PO\\IER LEVEL:
N/A NI DETECTOR POI.IER SUPPLY TURN-ON POI.IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of ventilation vent stack #2 -
NORMAL RANGE
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF LIQ RAD R1RM218C STATION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE C~ DISCHARGE TUNNEL (120)
RADIOACTIVITY OF RELEASED LIQ A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT DISCHARGE CANAL, OUTLET OF DISCH TUNNEL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the circulating water discharge tunnel
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU1 N/A EFF LIQ RAD R3RM209C STATION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE L~ DISPOSAL (108)
RADIOACTIVITY OF RELEASED LIQ A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG 13' LVL ACROSS FROM CHRG PMPS VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level in the liquid waste system.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT IO:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF LIQ RAD R3RM218C STATION: Surry UN IT: 1 PWR DATA POINT LIBRARY REFERENCE FILE SW FROM CC HX A RM (107A)
RADIOACTIVITY OF RELEASED LIQ A
CPM N/A 10.0 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG BASEMENT CC HEAT EXCHANGERS VARIABLE NI DETECTOR PO\\JER SUPPLY CUT-OFF PO\\JER LEVEL:
N/A NI DETECTOR PO\\JER SUPPLY TURN-ON PO\\JER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the service water effluent of c~nent cooling heat exchanger A
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:*
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF LIQ RAD R3RM227C STATION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE S~ FROM CC HX BRM (1078)
RADIOACTIVITY OF RELEASED LIQ A
CPM N/A 10.0 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG BASEMENT CC HEAT EXCHANGERS VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the service water effluent of component cooling heat exchanger B
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A EFF LIQ RAD R3RM228C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE SW FROM CC HX C RM (107C)
RADIOACTIVITY OF RELEASED LIQ A
CPM N/A 10.0 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG BASEMENT CC HEAT EXCHANGERS VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the service water effluent of c~nent cooling heat exchanger C.
(
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A H2 CONC A1GW001C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FJLE CNTMT H2 CONCENTRATION CONTAINMENT HYDROGEN CONC A
PCT N/A 0.0 10.0 N/A N/A p
2 AVERAGE - SEE SYSTEM DESCRIPTION AUX BLDG 13' LVL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Takes a sample of contairment atmosphere and measures the hydrogen concentration in the saq:,le.
The valid signals are averaged (2 signals if all are valid).
If none of the signals is valid, this point is marked invalid.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
05/20/91 SU1 N/A HL TEMP 1/A T1RC005A STATION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
GENERIC/COND DESC:
LOOP A ~R HOT LEG TEMP (RD)<>
STM GEN A INLET TEMPERATURE ANALOG/DIGITAL:
A ENGR UNITS/DIG STATES:
DEGF ENGR UNITS CONVERSION:
N/A MINIMUM INSTR RANGE:
0.0 MAXIMUM INSTR RANGE:
700.0 ZERO POINT
REFERENCE:
N/A REFERENCE POINT NOTES:
N/A PROC OR SENS:
s NUMBER OF SENSORS:
N/A HOW PROCESSED:
IS A DIRECT SENSOR INPUT N/A
- THIS SENSOR LOCATIONS:
LOOP A HOT LEG ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses loop A hot leg temperature.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR ~NITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES~
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A HL TEMP 2/B T1RC009A STATION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE LOOP B ~R HOT LEG TEMP (~T) <>
STM GEN B INLET TEMPERATURE A
DEGF N/A 0.0 700.0 N/A N/A s
N/A N/A
- THIS IS A DIRECT SENSOR INPUT LOOP B HOT LEG VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses loop B hot leg temperature.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU1 N/A HL TEMP 3/C T1RC013A STATION: Surry UNIT: 1 PIJR DATA POINT LIBRARY REFERENCE FILE LOOP C WR HOT LEG TEMP (BL)<>
STM GEN C INLET TEMPERATURE A
DEGF N/A 0.0 700.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT LOOP C HOT LEG VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses loop C hot leg temperature.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A HP SI FLOW F1RC005C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE TOT COLD LEG HHS! FLOW HIGH PRESSURE SI FLOW A
GPM N/A 0.0 1800.0 N/A N/A p
3 SUM - SEE SYSTEM DESCRIPTION CHRGING PMP DISCH UPSTRM OF COLD LEG VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Provides flow indication on the SI headers from the HHS!
pumps to the cold leg of each loop.
The 3 loop high head SI flows are totaled for this value.
If any one of the loop SI values is invalid, this point will be marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
07/01/91 SU1 N/A HP SI FLOW F1SI008A STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE HHS! HOT LEGS TOTAL FLOW (YW)
HIGH PRESSURE SI FLOW A
GPM N/A 0.0 1000.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT CHRG PMPS A,B,C DISCH UPSTRM OF HOT LEGS VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Senses total discharge of charging punps A, B, & C to RCS hot legs
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
CA.TA FEEDER:
~RC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
07/01/91 SU1 N/A HP SI FLOW F1SI009A STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE HHS! COLD LEGS TOTAL FLOW (RD)
HIGH PRESSURE SI FLOW A
GPM N/A 0.0 1000.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT CHRG PMPS A,B,C DISCH UPSTRM OF CLO LEGS VARIABLE NI DETECTOR PO\\JER SUPPLY CUT-OFF PO\\JER LEVEL:
N/A NI DETECTOR PO\\JER SUPPLY TURN-ON PO\\JER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Senses total discharge of charging punps A, B, & c to RCS cold legs
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
07/15/91 SU1 N/A LP SI FLOW F1SI002A STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE LHSI PMP A DISCH HOR FLOW (NL)
GPM 0 - 628" H20 0.0 5000.0 N/A N/A s
N/A N/A - THIS 15 A DIRECT SENSOR INPUT LHSI PMP A DISCH VARIABLE N/A NI DETECTOR PO'.IER SUPPLY TURN-ON PO'.IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses discharge of LHSI pump A.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOU PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
07/15/91 SU1 N/A LP SI FLOW F1SI003A STATION: Surry UNIT: 1 PUR DATA POINT LIBRARY REFERENCE FILE LHSI PMP B DISCH HDR FLOW (NL)
LOU PRESSURE SI FLOU A
GPM 0 - 628 11 H20 0.0 5000.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT LHSI PMP B DISCH VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POUER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses discharge of LHSI punp B.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A MAIN SL 1/A R1RM204C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE A MS HIGH RANGE (124)
STM GEN A STEAM LINE RAD LEVEL A
MR/HR N/A 1.OE-2 1.OE?
N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SAFEGUARDS AREA, 47 1 LEVEL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level in main steam line A.
PRINTED 09/05/91
DATE:
,)EACTOR UN IT:
i'ATA FEEDER:
IIRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A MAIN SL 2/B R1RM205C STATION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE B MS HIGH RANGE (125)
STM GEN B STEAM LINE RAD LEVEL A
MR/HR N/A 1.0E-2 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SAFEGUARDS AREA, 47' LEVEL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level in main steam line B.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A MAIN SL 3/C R1RM206C STATION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE CMS HIGH RANGE (126)
STM GEN C STEAM LINE RAD LEVEL A
MR/HR N/A 1.0E-2 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SAFEGUARDS AREA, 47' LEVEL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level in main steam line c.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF PO\\JER LEVEL:
STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU1 N/A MN FD FL 1/A F1FW005C SG A MAIN FEEDWATER FLOW STM GEN A MAIN FEEDWATER FLOW A
MLB/HR 0 - 286.2 11 H20 0.0 4.4 N/A N/A p
2 AVERAGE - SEE SYSTEM DESCRIPTION FEEDWTR HTR DISCH UPSTRM OF STM GEN A VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR OP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Senses flow in main feedwater line to steam generator A.
The average of the valid feed flow signals is used for this point.
If all signals are valid, 2 signals will be used.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU1 N/A MN FD FL 2/B F1FW006C SG B MAIN FEEDWATER FLOW STM GEN B MAIN FEEDWATER FLOW A
MLB/HR 0 - 286.2 11 H20 0.0 4.4 N/A N/A p
2 AVERAGE* SEE SYSTEM DESCRIPTION FEEDWTR HTR DISCH UPSTRM OF STM GEN B VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Senses flow in main feedwater line to steam generator B.
The average of the valid feed flow signals is used for this point.
If all signals are valid, 2 signals will be used.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 1 PYR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU1 N/A MN FD FL 3/C F1FY007C SG C MAIN FEEDYATER FLOY STM GEN C MAIN FEEDWATER FLOY A
MLB/HR 0 - 286.2 11 H20 0.0 4.4 N/A N/A p
2 AVERAGE - SEE SYSTEM DESCRIPTION FEEDWTR HTR DISCH UPSTRM OF STM GEN C VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses flow in main feedwater line to steam generator c.
The average of the valid feed flow signals is used for this point.
If all signals are valid, 2 signals will be used.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOii PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU1 N/A NI INTER RNG M1NM003C STATION: Surry UN IT: 1 P~R DATA POINT LIBRARY REFERENCE FILE INTERMEDIATE RANGE POIIER NUCLEAR INSTRUMENTS, INT RANGE A
AMPS Approximately 3e 120 % Power
- 1. OE-11 1.0E-3 N/A N/A p
2 MAXIMUM - SEE SYSTEM DESCRIPTION ADJACENT TO OUTSIDE OF REACTOR VESSEL VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A The highest valid intermediate range signal is used for this point.
2 intermediate range signals are available for use.
If neither of the intermediate range signals is valid, this point is marked invalid.
The intermediate range inputs are logrithmic in nature.
Therefore, the highest valid intermediate range signal is exponentiated to yield the value for this point
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A NI POWER RNG M1NM005C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE POWER RANGE AVERAGE POWER NUCLEAR INSTRUMENTS, POWER RANGE A
PCT N/A 0.0 120.0 N/A N/A p
4 AVERAGE - SEE SYSTEM DESCRIPTION ADJACENT TO OUTSIDE OF REACTOR VESSEL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF PO\\IER LEVEL:
N/A NI DETECTOR PO\\IER SUPPLY TURN-ON PO\\IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
The valid power range signals are averaged for this point.
4 power range signals are available for use.
If none of the power range signals is valid, this point is marked invalid
- PRINTED 09/05/91
_ ___:========_:____:::_------======---=c~-*
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOIJ PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POIJER SUPPLY CUT-OFF POIJER LEVEL:
NI DETECTOR PQl,IER SUPPLY TURN-ON POIJER LEVEL:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU1 N/A NI SOURC RNG M1NM001C SOURCE LEVEL POWER NUCLEAR INSTRUMENTS, SOURCE RNG A
CPS Approximately 1e*9
- 1e-3 % Power 1.0EO 1.0E6 N/A N/A p
2 MAXIMIM
- SEE SYSTEM DESCRIPTION ADJACENT TO OUTSIDE OF REACTOR VESSEL VARIABLE 1e*10 AMPS IR
<1e-10 AMPS IR N/A LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
NI cut_off requires the listed reading on either of the intermediate range instrunents and NI cut_on requires the listed reading on both of the intermediate range instruments (IR is on the intermediate range power scale). The highest valid source range signal is used for this point. 2 source range signals are available for use.
If neither of the source range signals is valid, this point is marked invalid.
The source range inputs are logrithmic in nature.
Therefore, the highest valid source range signal is exponentiated to yield the value for this point
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
D~TA FEEDER:
N~C ERDS PARAMETER:
PJINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 1 PYR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU1 N/A PRZR LEVEL L1RC002C PRESSURIZER LEVEL PRIMARY SYSTEM PRESSURIZER LEVEL A
PCT 1 % = 3.60 11 HZO 0.0 100.0 TNKBOT N/A p
3 AVERAGE - SEE SYSTEM DESCRIPTION PRESSURIZER-HP LOCATED 30-0' ABOVE LP VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A N/A YET Senses pressurizer level and provides alarm and control function inputs when the plant is operating normally.
The valid signals are averaged (3 signals if all are valid).
If none of the signals are valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU1 N/A RCS CHG/MU F1CH003A CHARGING LOOP FLOW (BL)
PRIM SYS CHARGING OR MAKEUP FLOW A
GPM 0 - 393.2 11 H20 0.0 150.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT CHARGING LINE UPSTRM OF REGEN HX VARIABLE NI DETECTOR POI.IER SUPPLY CUT-OFF POI.IER LEVEL:
N/A NI DETECTOR POI.IER SUPPLY TURN-ON POI.IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Flow transmitter FT-1122 transmits a signal to a controller located in the control cabinets, and to a flow indicator in the main control room.
The controller operates the charging water flow control valve (FCV-1122) to maintain a preset charging flow in conjunction with a signal from the pressurizer level instr1.111entation.
The two signals maintain pressurizer level within the proscribed band and limit the minimun and maxirrR.111 charging flow rates
- PRINTED 09/05/91
DATE:
05/20/91 REACTOR UNIT:
SU1 DATA FEEDER:
N/A NRC EROS PARAMETER:
RCS LTDN RAD POINT ID:
F1CH004A STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
LOW PRESSURE LETDOWN FLOW (WT)
GENERIC/COND DESC:
RAD LEVEL OF RCS LETDOWN LINE ANALOG/DIGITAL:
A ENGR UNITS/DIG STATES:
GPM ENGR UNITS CONVERSION:
0 - 400 11 H20 MINIMUM INSTR RANGE:
0.0 MAXIMUM INSTR RANGE:
150.0 ZERO POINT
REFERENCE:
N/A REFERENCE POINT NOTES:
N/A PROC OR SENS:
S NUMBER OF SENSORS:
N/A HOW PROCESSED:
N/A - THIS IS A DIRECT SENSOR INPUT SENSOR LOCATIONS:
LETDOWN LINE DWNSTRM OF NON-REGEN HX ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Provides indication of letdown stream flow rate in the Control Room
- PRINTED 09/05/91
~~---
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
05/20/91 SU1 N/A RCS L TON RAD R1RM201C STATION: Surry UNIT: 1 PYR DATA POINT LIBRARY REFERENCE FILE RCS LETDOYN LR (119)
RAD LEVEL OF RCS LETDOYN LINE A
CPM N/A 10.0 1.0E6 N/A N/A p
HOY PROCESSED:
EXPONENTIATED VALUE OF LOGARITHMIC INPUT SENSOR LOCATIONS:
AUX BLDG, 27' LVL OUTSIDE YALL*SAMPLE RM ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR PO\\.IER SUPPLY CUT-OFF PO\\.IER LEVEL:
N/A NI DETECTOR PO\\.IER SUPPLY TURN-ON PO\\.IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the RCS letdown line - LOY RANGE
- PRINTED 09/05/91
~-----------
DATE:
REACTOR UNIT:
L*ATA FEEDER:
IRC EROS PARAMETER:
F'OINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOii PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A RCS L TON RAD R1RM202C STATION: Surry UNIT: 1 PIIR DATA POINT LIBRARY REFERENCE FILE RCS LETDOIIN HR (118)
RAD LEVEL OF RCS LETDOIIN LINE A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG, 27' LVL OUTSIDE IIALL-SAMPLE RM VARIABLE NI DETECTOR POIIER SUPPLY CUT-OFF POIIER LEVEL:
N/A NI DETECTOR POIIER SUPPLY TURN-ON POIIER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the RCS letdown line - HIGH RANGE
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOIJ PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A RCS PRESSURE P1RC001C STATION: Surry UNIT: 1 PIJR DATA POINT LIBRARY REFERENCE FILE RCS AVERAGE PRESSURE REACTOR COOLANT SYSTEM PRESSURE A
PSIG N/A 0.0 3000.0 N/A N/A p
3 AVERAGE - SEE SYSTEM DESCRIPTION SEE SYSTEM DESCRIPTION VARIABLE NI DETECTOR PO\\IER SUPPLY CUT-OFF PO\\IER LEVEL:
N/A NI DETECTOR PQ',IER SUPPLY TURN-ON PO\\IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A PT-1455, PT-1456, and PT-1457 all measure pressurizer pressure (narrow range) and are used for pressurizer pressure protection.
The valid narrow range signals are averaged (3 signals if all are valid).
If none of the narrow range signals valid, the average of the valid wide range signals is used (2 signals if all are valid).
If none of the narrow or wide range signals is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU1 N/A REAC VES LEV L1RC001C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE REAC VSL FULL RANGE LEVEL REACTOR VESSEL WATER LEVEL A
PCT N/A 0.0 120.0 TNKBOT N/A p
5 AVERAGE - SEE SYSTEM DESCRIPTION HEAD VENT (TOP) & BOTTOM OF VESSEL VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
IIET The 2 reactor full range level signals are used in conjunction with the reactor coolant J)l.l1'> motor currents to calculate this value.
The full range readings are invalid if any RCP is running; therefore, this process value will be set invalid if any RCP motor current is greater than 5% of it's full load value.
If none of the RCP's are running, the average of the valid full range level signals is used to calculate this point.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A REAC VES LEV L1RC003C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE RVLIS DYNAMIC HEAD LEVEL REACTOR VESSEL WATER LEVEL A
PCT N/A 0.0 120.0 TNKBOT N/A p
5 AVERAGE - SEE SYSTEM DESCRIPTION HEAD VENT (TOP) & BOTTOM OF VESSEL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE Cc>>IPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
WET UNIQUE SYSTEM DESC:
The 2 reactor dynamic head level signals are used in conjunction with the reactor coolant~ motor currents to calculate this value.
The dynamic head readings are invalid if no RCP's are running; therefore, this process value will be set invalid if no RCP motor current is greater than 5% of it's full load value.
If none of the RCP's are running, the average of the valid dynamic head level signals is used to calculate this point
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:*
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A SG BD RAD 1A R1RM215C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE SG BLOW DOWN (112)
STM GEN A SLOWDOWN RAD LEVEL A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG BASEMENT BY EMERG SWG ROOM VARIABLE NI DETECTOR POWER SUPPLY CUT*OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN*ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of the blowdown of steam generator. Although this parameter is identified as the steam generator A blow down radiation monitor, this monitor can actually be aligned to any one of the three steam generators.
PRINTED 09/05/91
DATE:
~EACTOR UNIT:
)ATA FEEDER:
NRC EROS PARAMETER:
COINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR PO\\JER SUPPLY CUT-OFF PO\\JER LEVEL:
NI DETECTOR PO\\JER SUPPLY TURN-ON POIJER LEVEL:
05/20/91 SU1 N/A SG DB RAD 1A R1RM216C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE SG BLOW DOWN (113)
STM GEN A SLOWDOWN RAD LEVEL A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG BASEMENT BY EMERG SWG ROOM VARIABLE N/A N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of the blowdown of steam generator. Although this parameter is identified as the steam generator A blow down radiation monitor, this monitor can actually be aligned to any one of the three steam generators
- PRINTED 09/05/91
=-- -
DATE:
REACTOR UN IT :
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU1 N/A SG LEVEL 1/A L1FW001C STEAM GENERATOR A LEVEL STEAM GENERATOR A WATER LEVEL A
PCT 1 % = 1.44" H20 0.0 100.0 UTUBES N/A p
3 AVERAGE* SEE SYSTEM DESCRIPTION STM GEN-BOTTOM AT 684 11 & TOP AT 828 11 VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
WET Senses the water level in steam generator 1A.
The valid narrow range signals are averaged (3 signals if all are valid).
If none of the signals is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\.I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A SG LEVEL 1/A L1F\\.1004A STATION: Surry UNIT: 1 P\\.IR DATA POINT LIBRARY REFERENCE FILE SG A WR LEVEL (\\.IT) <>
STEAM GENERATOR A WATER LEVEL A
PCT 0 - 564 11 H20 0.0 100.0 TNKBOT N/A s
N/A N/A
- THIS IS A DIRECT SENSOR INPUT STEAM GENERATOR 1A VARIABLE NI DETECTOR PO\\.IER SUPPLY CUT-OFF PO\\.IER LEVEL:
N/A NI DETECTOR PO\\.IER SUPPLY TURN-ON PO\\.IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
WET UNIQUE SYSTEM DESC:
Senses the water level in steam generator 1A.
PRINTED 09/05/91
--**-------~--~-- **--***- - -*- ~----- --
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND OESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU1 N/A SG LEVEL 2/B L1FW002C STEAM GENERATOR B LEVEL STEAM GENERATOR B WATER LEVEL A
PCT 1 % = 1. 44 11 H20 0.0 100.0 UTUBES N/A p
3 AVERAGE - SEE SYSTEM DESCRIPTION STM GEN-BOTTOM AT 684 11 & TOP AT 828 11 VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
WET Senses the water level in steam generator 1B.
The valid narrow range signals are averaged (3 signals if all are valid).
If none of the signals is valid, this point is marked invalid.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOii PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A SG LEVEL 2/B L1FII008A STATION: Surry UNIT: 1 PIIR DATA POINT LIBRARY REFERENCE FILE SG B IIR LEVEL (BL)<>
STEAM GENERATOR B IIATER LEVEL A
PCT 0 - 564 11 H20 0.0 100.0 TNKBOT N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT STEAM GENERATOR 1B VARIABLE NI DETECTOR PO\\.IER SUPPLY CUT-OFF PO\\.IER LEVEL:
N/A NI DETECTOR PO\\.IER SUPPLY TURN-ON PO\\.IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
IIET UNIQUE SYSTEM DESC:
Senses the water level in steam generator 1B.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU1 N/A SG LEVEL 3/C L1FW003C STEAM GENERATOR C LEVEL STEAM GENERATOR C WATER LEVEL A
PCT 1 % = 1.44 11 H20 0.0 100.0 UTUBES N/A p
3 AVERAGE - SEE SYSTEM DESCRIPTION STM GEN-BOTTOM AT 684" & TOP AT 828 11 VARIABLE NI DETECTOR PO\\JER SUPPLY CUT-OFF PO\\JER LEVEL:
N/A NI DETECTOR PO\\JER SUPPLY TURN-ON PO\\JER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
WET UNIQUE SYSTEM DESC:
Senses the water level in steam generator 1C-The valid narrow range signals are averaged (3 signals if all are valid).
If none of the signals is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A SG LEVEL 3/C L 1FW012A STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE SG C WR LEVEL (YW) <>
STEAM GENERATOR C WATER LEVEL A
PCT 0 - 564 11 H20 0.0 100.0 TNKBOT N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT STEAM GENERATOR 1C VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR PO\\.IER SUPPLY TURN-ON PO\\.IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
WET UNIQUE SYSTEM DESC:
Senses the water level in steam generator 1C.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A SG PRESS 1/A P1MS001C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE SG A PRESSURE STEAM GENERATOR A PRESSURE A
PSIG N/A 0.0 1400.0 N/A N/A p
3 AVERAGE SEE SYSTEM DESCRIPTION OUTPUT OF STM GEN A VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A N/A Provides pressure of the steam which is on route from steam generator 1A to the main steam manifold.
The valid wide range signals are averaged (3 signals if all are valid).
If none of the signals is valid, this point is marked invalid.
PRINTED D9/D5/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A SG PRESS 2/B P1MS002C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE SG B PRESSURE STEAM GENERATOR B PRESSURE A
PSIG N/A 0.0 1400.0 N/A N/A p
3 AVERAGE - SEE SYSTEM DESCRIPTION OUTPUT OF STM GEN B VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR PO\\.IER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Provides pressure of the steam which is on route from steam generator 1B to the main steam manifold.
The valid wide range signals are averaged (3 signals if all are valid).
If none of the signals is valid, this point is marked invalid.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 su, N/A SG PRESS 3/C P1MS003C STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE SG C PRESSURE STEAM GENERATOR C PRESSURE A
PSIG N/A 0.0 1400.0 N/A N/A p
3 AVERAGE - SEE SYSTEM DESCRIPTION OUTPUT OF STM GEN C VARIABLE NI DETECTOR PO\\JER SUPPLY CUT-OFF PO\\JER LEVEL:
N/A NI DETECTOR PO\\JER SUPPLY TURN-ON PO\\JER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Provides pressure of the steam which is on route from steam generator 1C to the main steam manifold.
The valid wide range signals are averaged (3 signals if all are valid).
If none of the signals is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A STAB CLASS M3MM006A STATION: Surry UN IT: 1 PWR DATA POINT LIBRARY REFERENCE FILE.
SIGMA THETA (RCDR-6) (NL)
AIR STABILITY AT REACTOR SITE A
DEG N/A 0.0 45.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT PRIMARY TOWER TRAILER VARIABLE NI DETECTOR PO\\.IER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR PO\\.IER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A The output sigma theta signal is the standard deviation around the average direction
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A STAB CLASS M3MM008A STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE DELTA T (RCDR-9) (NL)
AIR STABILITY AT REACTOR SITE A
DEGC N/A
-5.0 15.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT 2 RTDs AT 35' & 150 1 ON PRIMARY TOWER VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Delta Tis lower t~rature minus upper temperature.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO'ol PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR PO'.IER SUPPLY 05/20/91 SU1 N/A STAB CLASS T3MM001A STATION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE AMB TEMPERATURE (RCDR-7) (NL)
AIR STABILITY AT REACTOR SITE A
DEGC N/A
-25.0 45.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT RTD AT 35 1 ON PRIMARY TO~ER VARIABLE CUT-OFF PO'.IER LEVEL:
N/A NI DETECTOR PO'.IER SUPPLY TURN-ON PO'.IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Measures air temperature at 35 1 elevation on the primary tower
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\.l PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A SUB MARGIN T1RC020C STAT ION: Surry UNIT: 1 P~R DATA POINT LIBRARY REFERENCE FILE CORE EXIT TSAT MARGIN SATURATION TEMP - HIGHEST CET A
DEGF N/A
-35.000 200.0 N/A N/A p
2 AVERAGE - SEE SYSTEM DESCRIPTION TSAT - CONTAINMENT CET - REACTOR CORE VARIABLE NI DETECTOR PO\\.lER SUPPLY CUT-OFF PO\\.lER LEVEL:
N/A NI DETECTOR PO\\.lER SUPPLY TURN-ON PO\\.lER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A The valid saturation margin inputs from the RVLIS system are averaged (2 signals if all are valid).
If none of the signals are valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOIJ PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POIJER SUPPLY CUT-OFF POIJER LEVEL:
05/20/91 SU1 N/A TEMP CORE EX T1RC001C STATION: Surry UNIT: 1 PIJR DATA POINT LIBRARY REFERENCE FILE PEAK CORE EXIT TEMP HIGHEST TEMPERATURE AT CORE EXIT A
DEGF N/A 0.0 2400.0 N/A N/A p
50 MAXIMUM - SEE SYSTEM DESCRIPTION EXIT OF SELECTED FUEL ASSEMBLIES IN-CORE VARIABLE N/A NI DETECTOR POIJER SUPPLY TURN-ON POIJER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the reactor coolant exit t~rature. The highest valid incore thermocouple is used.
If none of the thermocouples is valid, this point is marked invalid.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SUl N/A WIND DIR M3MM004A STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE WIND DIR LOWER (RCDR-4) (NL)
WIND DIR AT THE REACTOR SITE A
DEG N/A 0.0 360.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT 35 1 ON PRIMARY TOWER&30 1 ON BACKUP TOWER VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses wind direction at 35 feet.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\.I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU1 N/A WIND DIR M3MM005A STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE WIND DIR UPPER (RCDR-5) (NL)
WIND DIR AT THE REACTOR SITE A
DEG N/A 0.0 360.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT 150' ON PRIMARY TOWER VARIABLE NI DETECTOR PO\\.IER SUPPLY CUT-OFF PO\\.IER LEVEL:
N/A NI DETECTOR PO\\.IER SUPPLY TURN-ON PO\\.IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses wind direction at 150 feet.
PRINTED 09/05/91
DATE:
05/20/91 REACTOR UNIT:
SU1 DATA FEEDER:
N/A NRC EROS PARAMETER:
WIND SPEED POINT ID:
M3MM002A STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
WIND SPEED UPPER (RCDR-2) (NL)
GENERIC/COND DESC:
WIND SPEED AT THE REACTOR SITE ANALOG/DIGITAL:
A ENGR UNITS/DIG STATES:
MPH ENGR UNITS CONVERSION:
N/A MINIMUM INSTR RANGE:
0.0 MAXIMUM INSTR RANGE:
100.0 ZERO POINT
REFERENCE:
N/A REFERENCE POINT NOTES:
N/A PROC OR SENS:
S NUMBER OF SENSORS:
N/A HOW PROCESSED:
N/A - THIS IS A DIRECT SENSOR INPUT SENSOR LOCATIONS:
150° ON PRIMARY TOWER ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE Cc>>IPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Measures wind speed at 150 feet.
PRINTED 09/05/91
DATE:
REACTOR UN IT :
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
09/05/91 SU1 N/A IIIND SPEED M3MM001A STATION: Surry UNIT: 1 PIIR DATA POINT LIBRARY REFERENCE F.ILE IIIND SPEED LOIIER (RCDR-1) (NL)
IIIND SPEED AT REACTOR SITE A
MPH N/A 0.0 100.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT 35 1 ON PRIMARY TOIIER&30 1 ON BACKUP TOIIER VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Measures wind speed at 35 feet.
PRINTED 09/05/91
=:.::::_.::=============-=-=-~=--=---~------------------
1------
ATTACHMENT 5 SURRY UNIT 2 DPL'S
- --- *==cc-==---=~------------------------------~
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 2 PUR DATA POINT LIBRARY REFERENCE FILE 07 /01/91 SU2 N/A AX FD FL 1/A F2FU001A SG A AFU FLOU (RD)
STM GEN A AUX FEEDUATER FLOU A
GPM 0 - 39411 H20 0.0 350.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT AUX FEED PMP DISCH UPSTRM OF STM GEN A VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses auxiliary feedwater flow to steam generator A
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DiTA FEEDER:
NPC EROS PARAMETER:
POINT ID:
07/01/91 SU2 N/A AX FD FL 2/B F2FIJ002A STATION: Surry UNIT: 2 PIJR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT OESC:
SG B AFIJ FLOIJ (IJT)
GENERIC/CONO DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
STM GEN B AUX FEEOIJATER FLOIJ A
GPM 0 - 394 11 H20 MINIMUM INSTR RANGE:
0.0 MAXIMUM INSTR RANGE:
350.0 ZERO POINT
REFERENCE:
N/A REFERENCE POINT NOTES:
N/A PROC OR SENS:
S NUMBER OF SENSORS:
N/A HOIJ PROCESSED:
N/A - THIS IS A DIRECT SENSOR INPUT SENSOR LOCATIONS:
AUX FEED PMP DISCH UPSTRM OF STM GEN B ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR PO\\IER SUPPLY CUT-OFF PO\\IER LEVEL:
N/A NI DETECTOR PO\\IER SUPPLY TURN-ON PO\\IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE Cc>>IPENSATION FOR OP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses auxiliary feedwater flow to steam generator B.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 07/01/91 SU2 N/A AX FD FL 3/C F2FW003A SG C AFW FLOW (BL)
STM GEN C AUX FEEDWATER FLOW A
GPM 0 - 394 11 H20 0.0 350.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT AUX FEED PMP DISCH UPSTRM OF STM GEN C VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses auxiliary feedwater flow to steam generator C.
PRINTED 09/05/91
STATION: Surry PRINTED UNIT: 2 09/05/91 PWR DATA POINT LIBRARY REFERENCE FILE DATE:
05/20/91 REACTOR UNIT:
SU2 DATA FEEDER:
N/A NRC ERDS PARAMETER:
BWST LEVEL POINT ID:
L2CS001C PLANT SPEC POINT DESC:
RWST LEVEL GENERIC/COND DESC:
BORATED WATER STORAGE TANK LEVEL ANALOG/DIGITAL:
A ENGR UNITS/DIG STATES:
PCT ENGR UNITS CONVERSION:
1 % = 3997 GALLONS MINIMUM INSTR RANGE:
0.0 MAXIMUM INSTR RANGE:
100.0 ZERO POINT
REFERENCE:
TNKBOT REFERENCE POINT NOTES:
13500 GALLONS REMAIN AT ZERO POINT PROC OR SENS:
p NUMBER OF SENSORS:
4 HOW PROCESSED:
MINUMUM - SEE SYSTEM DESCRIPTION SENSOR LOCATIONS:
RWST ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
DRY UNIQUE SYSTEM DESC:
Indicates the level in the RWST.
The lowest valid signal is used.
If none of the 4 signals is valid, this point is marlced invalid
- DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A CL TEMP 1/A T2RC004A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE LOOP A WR T COLD (RD)<>
STM GEN A OUTLET TEMPERATURE A
OEGF N/A 0.0 700.0 N/A N/A s
N/A N/A
- THIS IS A DIRECT SENSOR INPUT LOOP A COLD LEG VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR PO'.IER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses loop A cold leg t~rature.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DAH FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR PO\\IER SUPPLY CUT-OFF PO\\IER LEVEL:
05/20/91 suz N/A CL TEMP 2/B T2RC008A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE LOOP B WR T COLD (WT)<>
STM GEN B OUTLET TEMPERATURE A
DEGF N/A 0.0 700.0 N/A N/A s
N/A N/A
- THIS IS A DIRECT SENSOR INPUT LOOP B COLD LEG VARIABLE N/A NI DETECTOR PO\\IER SUPPLY TURN-ON PO\\IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses loop B cold leg t~rature.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
05/20/91 SU2 N/A CL TEMP 3/C T2RC012A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/0 I GIT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STM GEN C OUTLET TEMPERATURE A
DEGF N/A 0.0 700.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT LOOP C COLO LEG VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR OP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM OESC:
Senses loop C cold leg t~rature
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU2 N/A CNTMNT RAD R2RM207C STATION: Surry UNIT: 2 PIIR DATA POINT LIBRARY REFERENCE FILE CNTMT AIR GASEOUS (260)
RADIATION LEVEL IN CONTAINMENT A
CPM N/A.
10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG, 45 1 1011 LEVEL IIEST END VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Continuously monitors the radiation level of air taken from the reactor contairment
- PRINTED 09/05/91
DATE:
REACTOR UN IT :
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU2 N/A CNTMNT RAD R2RM208C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CNTMT AIR PART (259)
RADIATION LEVEL IN CONTAINMENT A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG, 45' 10 11 LEVEL WEST END VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Continuously monitors the radiation level of particles in the air taken out of the reactor contairvnent
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DA"iA FEEDER:
NRC: EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A CNTMNT RAD R2RM209C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CNTMT AREA (263)
RADIATION LEVEL IN CONTAINMENT A
MR/HR N/A
- 1. OE-1 1.OE7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CONTAINMENT, INSIDE CRANE WALL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level within the reactor containment.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A CNTMNT RAD R2RM210C STATION: Surry UNIT: 2 P~R DATA POINT LIBRARY REFERENCE FILE CNTMT PER HATCH (261)
RADIATION LEVEL IN CONTAINMENT A
MR/HR N/A 1. OE-1 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG, OUTSIDE PERSONNEL HATCH VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level in the Personnel Hatch area.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU2 N/A CNTMNT RAD R2RM213C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT HR AREA (227)
RADIATION LEVEL IN CONTAINMENT A
R/HR N/A
- 3. 162E-1 1.0E7 N/A N/A p,
EXPONENTIATED VALUE OF LOGARITHMIC INPUT CONTAINMENT, INSIDE CRANE WALL 47 1 LEVEL VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the reactor contairvnent -
HIGH RANGE
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU2 N/A CNTMNT RAD R2RM214C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT HR AREA (228)
RADIATION LEVEL IN CONTAINMENT A
R/HR N/A 1.0 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CONTAINMENT, INSIDE CRANE WALL 47' LEVEL VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MCDE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the reactor containment -
HIGH RANGE
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
OA':"A FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HCN PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE COND A/E RAD R2RM217C CONDENSER AE (211)
COND AIR EJECTOR RADIOACTIVITY A
CPM N/A 10.0 1.OE6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG MEZZANINE OVERHEAD BY AE VARIABLE NI DETECTOR PCNER SUPPLY CUT-OFF PCNER LEVEL:
N/A NI DETECTOR PCNER SUPPLY TURN-ON PCNER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL _REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Continuously monitors the gaseous effluent from the condenser air ejectors.
On high radiation any radioactive air is diverted into the reactor contair,nent
- PRINTED 09/05/91
!-------~*------------------------------ -
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
05/20/91 SU2 N/A CORE FLOIJ F2RC004C STATION: Surry UNIT: 2 PIJR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
GENERIC/COND DESC:
AVERAGE RCS LOOP FLOIJ TOTAL REACTOR FLOIJ ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
A PCT 0 - 460 11 H20 0.0 120.0 N/A N/A p
9 AVERAGE - SEE SYSTEM DESCRIPTION STM GEN DISCHARGE UPSTRM OF RCP VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the flow of coolant from the steam generator to the reactor coolant~-
The average of the 3 loop calculated average flows is used for this point.
The 3 loop average values are calculated by taking the average of the valid flow signals for each loop.
If all loop flow signals are valid, 3 flow readings will be used for each loop
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\.I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR PO\\.IER SUPPLY CUT-OFF PO\\.IER LEVEL:
05/20/91 suz N/A CTMNT PRESS P2LM001C STATION: Surry UNIT: 2 P\\.IR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT PRESSURE CONTAINMENT PRESSURE A
PSIA N/A 0.0 180.0 N/A N/A p
4 AVERAGE - SEE SYSTEM DESCRIPTION CABLE PENETRATION AREA IN AUX BLDG VARIABLE N/A NI DETECTOR PO\\.IER SUPPLY TURN-ON PO\\.IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses reactor contairvnent pressure.
The valid intermediate range signals (4 signals if all are valid) are averaged.
If no intermediate range signals are valid, the average of the wide range signals is used (2 signals if all are valid).
If no signals are valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\J PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR PO\\olER SUPPLY CUT-OFF PO\\olER LEVEL:
05/20/91 SU2 N/A CTMNT SMP NR L2DA002C STATION: Surry UNIT: 2 P\\JR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT NR SUMP LEVEL CONTAINMENT SUMP NR LEVEL A
INCH 1 IN= 2369 GALLONS 4.5 26.5 TNKBOT 280 GALLONS REMAIN AT ZERO POINT p
2 MAXIMUM - SEE SYSTEM DESCRIPTION CONTAINMENT SUMP VARIABLE N/A NI DETECTOR PO\\olER SUPPLY TURN-ON PO\\olER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Senses reactor containments~ level and provides a high level alarm.
The largest valid narrow range signal is used for this point.
If all signals are val id, 2 signals are considered.
If both signals are invalid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DA'"A FEEDER:
NR1: EROS PARAMETER:
PO!NT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A CTMNT SMP YR L2DA001C STATION: Surry UNIT: 2 PYR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT YR SUMP LEVEL CONTAINMENT SUMP YR LEVEL A
FT 1 FT= 58343 GALLONS 0.43 9.0 TNKBOT N/A p
2 AVERAGE
- SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
The valid wide range signals are averaged (2 signals if all are valid).
If neither signal is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
05/20/91 SU2 N/A CTMNT TEMP T2LM001C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
CONTAINMENT TEMPERATURE CONTAINMENT TEMPERATURE A
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
DEGF N/A 50.0 300.0 N/A N/A.
p 2
AVERAGE - SEE SYSTEM DESCRIPTION REACTOR CONTAINMENT VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE CCJ4PENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses reactor contairvnent temperature.
The valid signals are averaged (2 signals if all are valid). If neither signal is valid, this point is marked invalid.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENER!C/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPO!NTS:
05/20/91 SU2 N/A EFF GAS RAD R2RM203C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE TD AFW PUMP EXHAUST (229)
RADIOACTIVITY OF RELEASED GASES A
MR/HR N/A 1.0E-2 1.0E?
N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SAFEGUARDS AREA, OUTSIDE WALL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR PO\\.IER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of the unit 2 turbine-driven auxiliary feed pump exhaust ("Terry" turbine)
- PRINTED 09/05/91
STATION: Surry PRINTED UNIT: 2 09/05/91 PIIR DATA POINT LIBRARY REFERENCE FILE DATE:
05/20/91 REACTOR UNIT:
SU2 DATA FEEDER:
N/A NRC EROS PARAMETER:
EFF GAS RAD POINT ID:
R3RM203C PLANT SPEC POINT DESC:
PROCESS VENT GAS (102)
GENERIC/COND DESC:
RADIOACTIVITY OF RELEASED GASES ANALOG/0 I GIT AL:
A ENGR UNITS/DIG STATES:
CPM ENGR UNITS CONVERSION:
N/A MINIMUM INSTR RANGE:
10.0 MAXIMUM INSTR RANGE:
1.0E6 ZERO POINT
REFERENCE:
N/A REFERENCE POINT NOTES:
N/A PROC OR SENS:
p NUMBER OF SENSORS:
1 HOii PROCESSED:
EXPONENT! ATED VALUE OF LOGARITHMIC INPUT SENSOR LOCATIONS:
AUX BLDG 45 1 10" LEVEL IIEST END ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR POIIER SUPPLY CUT-OFF POIIER LEVEL:
N/A NI DETECTOR POIIER SUPPLY TURN-ON POIIER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level of air taken from the process vent
- DATE:
REACTOR UN IT:
Di,TA FEEDER:
Nf.C ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU2 N/A EFF GAS RAD R3RM204C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PV HIGH RANGE (130-2)
RADIOACTIVITY OF RELEASED GASES A
UCI/CC N/A 1.0E-3 1.0ES N/A NIA p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the process vent - HIGH RANGE
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU2 N/A EFF GAS RAD R3RM205C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PV HIGH RANGE (130-2)
RADIOACTIVITY OF RELEASED GASES A
UCI/S N/A 1.0E4 1.0E12 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the process vent - HIGH RANGE
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\J PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A EFF GAS RAD R3RM206C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PV NORMAL (130-1)
RADIOACTIVITY OF RELEASED GASES A
UCI/CC N/A 1.0E-8 1.0 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF PO\\JER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the process vent - NORMAL RANGE
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU2 N/A EFF GAS RAD R3RM207C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PV NORMAL (130-1)
RADIOACTIVITY OF RELEASED GASES A
UCI/S N/A 1.0 1.0EB N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the process vent - NORMAL RANGE
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NR: EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A EFF GAS RAD R3RM208C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PV PARTICULATE (101)
RADIOACTIVITY OF RELEASED GASES A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG 45' 1011 LEVEL WEST END VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of particles in the air taken out of the process vent
- PRINTED 09/05/91
*--- - -------~***-**--*-------- --*---- -
STATION: Surry PRINTED UNIT: 2 09/05/91 P~R DATA POINT LIBRARY REFERENCE FILE DATE:
05/20/91 REACTOR UNIT:
SU2 DATA FEEDER:
N/A NRC ERDS PARAMETER:
EFF GAS RAD POINT ID:
R3RM219C PLANT SPEC POINT DESC:
VENT VENT GASEOUS C 110)
GENERIC/COND DESC:
RAD IOACTI VI TY OF RELEASED GASES ANALOG/DIG IT AL:
A ENGR UNITS/DIG STATES:
CPM ENGR UNITS CONVERSION:
N/A MINIMUM INSTR RANGE:
10.0 MAXIMUM INSTR RANGE:
1.0E6 ZERO POINT
REFERENCE:
N/A REFERENCE POINT NOTES:
N/A PROC OR SENS:
p NUMBER OF SENSORS:
1 HOW PROCESSED:
EXPONENTIATED VALUE OF LOGARITHMIC INPUT SENSOR LOCATIONS:
AUX BLDG 45' 1011 LEVEL EAST END ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR PO\\JER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR PO\\IER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE Cc>>4PENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level of air taken from ventilation vent stack #2
- DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A EFF GAS RAD R3RM220C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE VV PARTICULATE (109)
RADIOACTIVITY OF RELEASED GASES A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG 45' 10" LEVEL EAST END VARIABLE NI DETECTOR POWER SUPPLY CUT*OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN*ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of particles in the air taken from ventilation vent stack #2.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU2 N/A EFF GAS RAD R3RM221C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE VV 1 GAS RAD MON (104)
RADIOACTIVITY OF RELEASED GASES A
CPM N/A 10.0 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT UNIT 2 SWITCHGEAR ROOM (NORTH WALL)
VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of air taken from the
- ventilation vent
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A EFF GAS RAD R3RM223C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE VV HIGH RANGE (131-2)
RADIOACTIVITY OF RELEASED GASES A
UCI/CC N/A 1.0E-3 1.0E5 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEi. REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of ventilation vent stack #2 -
HIGH RANGE
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:.
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A EFF GAS RAD R3RM224C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE VV HIGH RANGE (131-2)
RADIOACTIVITY OF RELEASED GASES A
UCI/S N/A 1.0E4 1.0E12 N/A N/A p,
EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of ventilation vent stack #2 -
HIGH RANGE
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A EFF GAS RAD R3RM225C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE VV NORMAL RANGE (131-1)
RADIOACTIVITY OF RELEASED GASES A
UCI/CC N/A 1.0E-8 1.0 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of ventilation vent stack #2 -
NORMAL RANGE.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU2 N/A EFF GAS RAD R3RM226C STATION: Surry UNIT: 2 P~R DATA POINT LIBRARY REFERENCE FILE VV NORMAL RANGE (131-1)
RADIOACTIVITY OF RELEASED GASES A
UCI/S N/A
- 1. 0 1.DEB N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT CABLE SPREADING ROOM VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of ventilation vent stack #2 -
NORMAL RANGE
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A EFF GAS RAD R2RM203C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE TD AFW PUMP EXHAUST (229)
RADIOACTIVITY OF RELEASED GASES A
MR/HR N/A 1.0E-2 1.0E7 N/A N/A p,
EXPONENTIATED VALUE OF LOGARITHMIC INPUT SAFEGUARDS AREA, OUTSIDE WALL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of the unit 2 turbine-driven auxiliary feed~ exhaust ("Terry" turbine)
- PRINTED 09/05/91
==
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOIJ PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR PO\\JER SUPPLY CUT-OFF PO\\JER LEVEL:
05/20/91 SU2 N/A EFF LIQ RAD R3RM209C STATION: Surry UNIT: 2 PIJR DATA POINT LIBRARY REFERENCE FILE LIJ DISPOSAL (108)
RADIOACTIVITY OF RELEASED LIQ A
CPM N/A 10.0 1.OE6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG 13' LVL ACROSS FROM CHRG PMPS VARIABLE N/A NI DETECTOR PO\\JER SUPPLY TURN-ON PO\\JER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the liquid waste system.
. PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A EFF LIQ RAD R3RM218C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FI~E SW FROM CC HX A RM (107A)
RADIOACTIVITY OF RELEASED LIQ A
N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG BASEMENT CC HEAT EXCHANGERS VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the service water effluent of component cooling heat exchanger-A
- PRINTED 09/05/91
- --~-------.--- --- -----*---*-- -------*---- ------ -----------
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A EFF LIQ RAD R3RM227C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE SW FROM CC HX BRM (107B)
RADIOACTIVITY OF RELEASED LIQ A
CPM N/A 10.0 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG BASEMENT CC HEAT EXCHANGERS VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the service water effluent of c~nent cooling heat exchanger B
- PRINTED 09/05/91
*---*--------==="~--~==~-
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A EFF LIQ RAD R3RM228C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE SW FROM CC HX C RM (107C)
RADIOACTIVITY OF RELEASED LIQ A
CPM N/A 10.0 1.OE7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG BASEMENT CC HEAT EXCHANGERS VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the service water effluent of c~nent cooling heat exchanger C
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A EFF LIQ RAD R2RM218C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CW DISCHARGE TUNNEL (220)
RADIOACTIVITY OF RELEASED LIQ A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG MEZZANINE OVERHEAD BY AE VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Continuously monitors the gaseous effluent from the condenser air ejectors.
On high radiation any radioactive air is diverted into the reactor contairvnent
- PRINTED 09/05/91
r:=============- -----=====----~- -- ------------------------
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A H2 CONC A2GW001C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CNTMT H2 CONCENTRATION CONTAINMENT HYDROGEN CONC A
PCT N/A 0.0 10.0 N/A N/A p
2 AVERAGE - SEE SYSTEM DESCRIPTION AUX BLDG 13' LVL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Takes a sa~le of containnent atmosphere and measures the hydrogen concentration in the sa~le. The valid signals are averaged (2 signals if all are valid). If none of the signals is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A HL TEMP 1/A T2RC005A STATION: Surry UNIT: 2 PYR DATA POINT LIBRARY REFERENCE FILE LOOP A YR HOT LEG TEMP (RD)<>
STM GEN A INLET TEMPERATURE A
DEGF N/A 0.0 700.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT LOOP A HOT LEG VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses loop A hot leg temperature.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:-
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU2 N/A HL TEMP 2/B T2RC009A.
STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE LOOP B WR HOT LEG TEMP (WT)<>
STM GEN B INLET TEMPERATURE A
DEGF N/A 0.0 700.0 N/A N/A s
N/A N/A
- THIS IS A DIRECT SENSOR INPUT LOOP B HOT LEG VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses loop B hot leg t~rature.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\.I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A HL TEMP 3/C T2RC013A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE LOOP C WR HOT LEG TEMP (BL)<>
STM GEN C INLET TEMPERATURE A
DEGF N/A o.o 700.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT LOOP C HOT LEG VARIABLE NI DETECTOR PO\\.IER SUPPLY CUT-OFF PO\\.IER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON PO\\.IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses loop C hot leg terr.,erature.
PRINTED 09/05/91
1-------------- ----*--------------* *---
DATE:
REACTOR UN IT :
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 suz N/A HP SI FLOW F2RC005C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE TOT COLD LEG HHS! FLOW HIGH PRESSURE SI FLOW A
GPM N/A 0.0 1800.0 N/A N/A p
3 SUM - SEE SYSTEM DESCRIPTION CHRGING PMP DISCH UPSTRM OF COLD LEG VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Provides flow indication on the SI headers from the HHS!
pumps to the cold leg of each loop.
The 3 loop high head SI flows are totaled for this value.
If any one of the loop SI values is invalid, this point will be marked invalid
- PRINTED 09/05/91
DATE:
07/01/91 REACTOR UNIT:
SU2 DATA FEEDER:
N/A NRC ERDS PARAMETER:
F2SI008A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
HHS! HOT LEGS TOTAL FLOW (YW)
GENERIC/COND DESC:
HIGH PRESSURE SI FLOW ANALOG/DIGITAL:
A ENGR UNITS/DIG STATES:
GPM ENGR UNITS CONVERSION:
N/A MINIMUM INSTR RANGE:
0.0 MAXIMUM INSTR RANGE:
1000.00 ZERO POINT
REFERENCE:
N/A REFERENCE POINT NOTES:
N/A PROC OR SENS:
S NUMBER OF SENSORS:
N/A HOW PROCESSED:
N/A - THIS IS A DIRECT SENSOR INPUT SENSOR LOCATIONS:
CHRG PMPS A,B,C DISCH UPSTRM OF HOT LEGS ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Senses total discharge of charging punps A, B, & C to RCS hot legs
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
')ATA FEEDER:
~RC EROS PARAMETER:
POINT ID:
07/01/91 SU2 N/A HP SI FLOW F2SI009A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
GENERIC/COND DESC:
HHS! COLD LEGS TOTAL FLOW (RD)
HIGH PRESSURE SI FLOW ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
A GPM N/A 0.0 1000.00 N/A
.N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT CHRG PMPS A,B,C DISCH UPSTRM OF CLO LEGS VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses total discharge of charging~ A, B, & C to RCS cold legs
- PRINTED 09/05/91
DATE:
07/15/91 REACTOR UNIT:
SU2 DATA FEEDER:
N/A NRC ERDS PARAMETER:
F2SI002A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
LHSI PMP A DISCH HDR FLOW (NL)
GENERIC/COND DESC:
LOW PRESSURE SI FLOW ANALOG/DIGITAL:
A ENGR UNITS/DIG STATES:
GPM ENGR UNITS CONVERSION:
0 - 628" HZO MINIMUM INSTR RANGE:
0.0 MAXIMUM INSTR RANGE:
5000.0 ZERO POINT
REFERENCE:
N/A REFERENCE POINT NOTES:
N/A PROC OR SENS:
S NUMBER OF SENSORS:
N/A HOW PROCESSED:
N/A - THIS IS A DIRECT SENSOR INPUT SENSOR LOCATIONS:
LHSI PMP A DISCH ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses discharge of LHSI ?U1') A.
PRINTED 09/05/91
**----------------------::-=---~----~~~~~=
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
07/15/91 SU2 N/A LP SI FLOW F2SI003A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE LHSI PMP B DISCH HDR FLOW (NL)
GPM 0 - 628" H20 0.0 5000.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT LHSI PMP B DISCH VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE CCJ4PENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses discharge of LHSI ~
B.
PRINTED 09/05/91
1--- ------------------------------- - ------
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A MAIN SL 1/A R2RM204C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE A MS HIGH RANGE (224)
STM GEN A STEAM LINE RAD LEVEL A
MR/HR N/A 1.0E-2 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SAFEGUARDS AREA, 47' LEVEL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level in main steam line A.
PRINTED 09/05/91
DATE:
REACTOR UN IT :
DHA FEEDER:
N~C EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A MAIN SL 2/B R2RM205C STATION: Surry UNIT: 2 P~R DATA POINT LIBRARY REFERENCE FILE B HS HIGH RANGE (225)
STH GEN B STEAM LINE RAD LEVEL A
MR/HR N/A 1.0E-2 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SAFEGUARDS AREA, 47' LEVEL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation Level in main steam line B.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COMO DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY 05/20/91 SU2 N/A MAIN SL 3/C R2RM206C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CMS HIGH RANGE (226)
STM GEN C STEAM LINE RAD LEVEL A
MR/HR N/A 1.0E-2 1.0E7 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT SAFEGUARDS AREA, 47' LEVEL VARIABLE CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level in main steam line C.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU2 N/A MN FD FL 1/A F2F\\.1005C SG A MAIN FEED\\.IATER FLOW STM GEN A MAIN FEED\\.IATER FLOW A
MLB/HR 0 - 286.2" H20 0.0 4.4 N/A N/A p
2 AVERAGE - SEE SYSTEM DESCRIPTION FEEDWTR HTR DISCH UPSTRM OF STM GEN A VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses flow in main feedwater Line to steam generator A.
The average of the valid feed flow signals is used for this point.
If all signals are valid, 2 signals will be used
- PRINTED 09/05/91
F DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU2 N/A MN FD FL 2/B F2FW006C SG B MAIN FEEDWATER FLOW STM GEN B MAIN FEEDWATER FLOW A
MLB/HR 0 - 286.2" H20 0.0 4.4 N/A N/A p
2 AVERAGE - SEE SYSTEM DESCRIPTION FEEDWTR HTR DISCH UPSTRM OF STM GEN B VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Senses flow in main feedwater line to steam generator B.
The average of the valid feed flow signals is used for this point.
If all signals are valid, 2 signals will be used.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NR: ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU2 N/A MN FD FL 3/C F2FW007C SG C MAIN FEEDWATER FLOW STM GEN C MAIN FEEDWATER FLOW A
MLB/HR 0 - 286.2 11 H20 0.0 4.4 N/A N/A p
2 AVERAGE - SEE SYSTEM DESCRIPTION FEEDWTR HTR DISCH UPSTRM OF STM GEN C VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Senses flow in main feedwater line to steam generator C.
The average of the valid feed flow signals is used for this point.
If all signals are valid, 2 signals will be used
- PRINTED 09/05/91
DATE:
REACTOR UN IT :
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/CONO DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A NI INTER RNG M2NM003C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE INTERMEDIATE RANGE POWER NUCLEAR INSTRUMENTS, INT RANGE A
AMPS Approximately 3e*6 - 120 % Power 1.0E-11
- 1. OE-3 N/A N/A p
2 MAXIMUM* SEE SYSTEM DESCRIPTION ADJACENT TO OUTSIDE OF REACTOR VESSEL VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR OP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A The highest valid intermediate range signal is used for this point. 2 intermediate range signals are available for use.
If neither of the intermediate range signals is valid, this point is marked invalid. The intermediate range inputs are logrithmic in nature.
Therefore, the highest valid intermediate range signal is exponentiated to yield the value for this point
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A NI POWER RNG M2NM005C STATION: Surry UN IT: 2 PWR DATA POINT LIBRARY REFERENCE FILE POWER RANGE AVERAGE.POWER NUCLEAR INSTRUMENTS, POWER RANGE A
PCT N/A 0.0 120.0 N/A N/A p
4 AVERAGE - SEE SYSTEM DESCRIPTION ADJACENT TO OUTSIDE OF REACTOR VESSEL VARIABLE NI DETECTOR PO',IER SUPPLY CUT-OFF PO',IER LEVEL:
N/A NI DETECTOR PO\\IER SUPPLY TURN-ON PO',IER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A The valid power range signals are averaged for this point.
4 power range signals are available for use.
If none of the power range signals is valid, this point is marked invalid
- PRINTED 09/05/91
STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE DATE:
05/20/91 REACTOR UNIT:
SU2 DATA FEEDER:
N/A NRC EROS PARAMETER:
NI SOURC RNG POINT ID:
M2NM001C PLANT SPEC POINT DESC:
SOURCE LEVEL POWER GENERIC/COND DESC:
NUCLEAR INSTRUMENTS, SOURCE RNG ANALOG/DIGITAL:
A ENGR UNITS/DIG STATES:
CPS ENGR UNITS CONVERSION:
Approximately 1e 1e-3 % Power MINIMUM INSTR RANGE:
1.0EO MAXIMUM INSTR RANGE:
1.0E6 ZERO POINT
REFERENCE:
N/A REFERENCE POINT NOTES:
N/A PROC OR SENS:
P NUMBER OF SENSORS:
2 HOW PROCESSED:
MAXIMUM - SEE SYSTEM DESCRIPTION SENSOR LOCATIONS:
ADJACENT TO OUTSIDE OF REACTOR VESSEL ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
1e-10 AMPS IR NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
<1e-10 AMPS IR INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A NI cut_off requires the listed reading on either of the intermediate range instrunents and NI cut_on requires the listed reading on both of the intermediate range instrunents CIR is on the intermediate range power scale).
The highest valid source range signal is used for this point. 2 source range signals are available for use.
If neither of the source range signals is valid, this point is marked invalid.
The source range inputs are logrithmic in nature.
Therefore, the highest valid source range signal is exponentiated to yield the value for this point
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
Di,TA FEEDER:
N~C ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU2 N/A PRZR LEVEL L2RC002C PRESSURIZER LEVEL PRIMARY SYSTEM PRESSURIZER LEVEL A
PCT 1 % = 3.60 11 H20 0.0 100.0 TNKBOT N/A p
3 AVERAGE - SEE SYSTEM DESCRIPTION PRESSURIZER-HP LOCATED 32.0' ABOVE LP ALARM/TRIP SETPOINTS:
VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
WET UNIQUE SYSTEM DESC:
Senses pressurizer level and provides alarm and control function inputs when the plant is operating normally.
The valid signals are averaged (3 signals if all are valid).
If none of the signals are valid, this point is marked invalid.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/0 I GIT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A RCS CHG/MU F2CH003A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHARGING LOOP FLOW (BL)
PRIM SYS CHARGING OR MAKEUP FLOW A
GPM 0 - 393.2 11 H20 0.0 150.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT CHARGING LINE UPSTRM OF REGEN HX VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Flow transmitter FT-2122 transmits a signal to a controller located in the control cabinets, and to a flow indicator in the main control room.
The controller operates the charging water flow control valve (FCV-2122) to maintain a preset charging flow in conjunction with a signal from the pressurizer level instrunentation.
The two signals maintain pressurizer level within the proscribed band and limit the minimum and maxillll.lll charging flow rates
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU2 N/A RCS LTDN RAD F2CH004A LOW PRESSURE LETDOWN FLOW (WT)
RAD LEVEL OF RCS LETDOWN LINE A
GPM 0 - 400 11 H20 0.0 150.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT LETDOWN LINE DWNSTRM OF NON-REGEN HX VARIABLE NI DETECTOR PO\\JER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Provides indication of letdown stream flow rate in the Control Room
- PRINTED 09/05/91
DATE:
REACTOR UN IT :
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A RCS LTDN RAD R2RM201C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE RCS LETDOWN HR (218)
RAD LEVEL OF RCS LETDOWN LINE A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG, 27' LVL OUTSIDE WALL-SAMPLE RM VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level in the RCS letdown line - HIGH RANGE
- PRINTED 09/05/91
DATE:
REACTOR UN IT :
DATA FEEDER:
NR: EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\J PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A RCS L TDN RAD R2RM202C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE RCS LETDOWN LR (219)
RAD LEVEL OF RCS LETDOWN LINE A
CPM N/A 10.0 1.0E6 N/A N/A p
EXPONENTIATED VALUE OF LOGARITHMIC INPUT AUX BLDG, 27' LVL OUTSIDE WALL-SAMPLE RM VARIABLE NI DETECTOR PO\\JER SUPPLY CUT-OFF PO\\JER LEVEL:
N/A NI DETECTOR PO\\JER SUPPLY TURN-ON PO\\JER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Monitors the radiation level in the RCS letdown line - LOW RANGE.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A RCS PRESSURE P2RC001C STATION: Surry UNIT: 2 P~R DATA POINT LIBRARY REFERENCE FILE RCS AVERAGE PRESSURE REACTOR COOLANT SYSTEM PRESSURE A
PSIG N/A 0.0 3000.0 N/A N/A p
3 AVERAGE* SEE SYSTEM DESCRIPTION SEE SYSTEM DESCRIPTION VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A PT-2455, PT-2456, and PT-2457 all measure pressurizer pressure (narrow range) and are used for pressurizer pressure protection. The valid narrow range signals are averaged (3 signals if all are valid).
If none of the narrow range signals valid, the average of the valid wide range signals is used (2 signals if all are valid). If none of the narrow or wide range signals is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\.I PROCESSED:.
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POYER SUPPLY CUT-OFF PO\\.IER LEVEL:
NI DETECTOR PO\\.IER SUPPLY TURN-ON PO\\.IER LEVEL:
05/20/91 SU2 NIA REAC VES LEV L2RC001C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE REAC VSL FULL RANGE LEVEL REACTOR VESSEL WATER LEVEL A
PCT NIA 0.0 120.0 TNKBOT NIA p
5 AVERAGE SEE SYSTEM DESCRIPTION HEAD VENT (TOP) & BOTTOM OF VESSEL VARIABLE N/A N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
WET UNIQUE SYSTEM DESC:
The 2 reactor full range level signals are used in conjunction with the reactor coolant pump motor currents to calculate this value.
The full range readings are invalid if any RCP is running; therefore, this process value will be set invalid if any RCP motor current is greater than 5% of it's full load value.
If none of the RCP's are running, the average of the valid full range level signals is used to calculate this point
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOIJ PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POIJER SUPPLY CUT-OFF POIJER LEVEL:
05/20/91 SU2 N/A REAC VES LEV L2RC003C STATION: Surry UNIT: 2 PIJR DATA POINT LIBRARY REFERENCE FILE RVLIS DYNAMIC HEAD LEVEL REACTOR VESSEL IJATER LEVEL A
PCT N/A 0.0 120.0 TNKBOT N/A p
5 AVERAGE - SEE SYSTEM DESCRIPTION HEAD VENT (TOP) & BOTTOM OF VESSEL VARIABLE N/A NI DETECTOR POIJER SUPPLY TURN-ON POIJER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
IJET UNIQUE SYSTEM DESC:
The 2 reactor dynamic head level signals are used in conjunction with the reactor coolant~ motor currents to calculate this value.
The dynamic head readings are invalid if no RCP's are running; therefore, this process value will be set invalid if no RCP motor current is greater than 5% of it's full load value.
If none of the RCP's are running, the average of the valid dynamic head level signals is used to calculate this point
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NliC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A SG BD RAD 1A R2RM215C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE SG BLOW DOWN (212)
STM GEN A SLOWDOWN RAD LEVEL A
CPM N/A 10.0 1.OE6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG BASEMENT BY EMERG SWG ROOM VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of the blowdown of steam generator. Although this parameter is identified as the steam generator A blow down radiation monitor, this monitor can actually be aligned to any one of the three steam generators.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A SG BO RAD 1A R2RM216C ST A Tl ON: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE SG BLOW DOWN (213)
STM GEN A SLOWDOWN RAD LEVEL A
CPM N/A 10.0 1.0E6 N/A N/A p
1 EXPONENTIATED VALUE OF LOGARITHMIC INPUT TURBINE BLDG BASEMENT BY EMERG SWG ROOM VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the radiation level of the blowdown of steam generator. Although this parameter is identified as the steam generator A blow down radiation monitor, this monitor can actually be aligned to any one of the three steam generators.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU2 N/A SG LEVEL 1/A L2FW001C STEAM GENERATOR A LEVEL STEAM GENERATOR A WATER LEVEL A
PCT 1 % = 1.44" H20 0.0 100.0 UTUBES N/A p
3 AVERAGE - SEE SYSTEM DESCRIPTION STM GEN-BOTTOM AT 684 11 & TOP AT 828 11 VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
WET Senses the water level in steam generator 2A.
The valid narrow range signals are averaged (3 signals if all are valid).
If none of the signals is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UN IT :
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU2 N/A SG LEVEL 1/A L2F'w004A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE SG A WR LEVEL (WT)<>
STEAM GENERATOR A WATER LEVEL A
PCT 0 - 564 11 H20 0.0 100.0 TNKBOT N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT STEAM GENERATOR 2A VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
WET Senses the water level in steam generator 2A-PRINTED 09/05/91
---- - ---* ----- - ---**-*- ---. -- -----=---,-,=~~~~
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 SU2 N/A SG LEVEL 2/B L2FW002C STEAM GENERATOR B LEVEL STEAM GENERATOR B WATER LEVEL A
PCT 1 % = 1.44 11 H20 0.0 100.0 UTUBES N/A p
3 AVERAGE - SEE SYSTEM DESCRIPTION STM GEN-BOTTOM AT 684 11 & TOP AT 82811 VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
WET UNIQUE SYSTEM DESC:
Senses the water level in steam generator 2B.
The valid narrow range signals are averaged (3 signals if all are valid).
If none of the signals is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
05/20/91 SU2 N/A SG LEVEL 2/8 L2FW008A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STEAM GENERATOR 8 WATER LEVEL A
PCT 0 - 564 11 HZO 0.0 100.0 TNKBOT N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT STEAM GENERATOR 28 VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
WET UNIQUE SYSTEM DESC:
Senses the water level in steam generator 28.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENER!C/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
STATION: Surry UN IT: 2 PWR DATA POINT LIBRARY REFERENCE FILE 05/20/91 suz N/A SG LEVEL 3/C L2FW003C STEAM GENERATOR C LEVEL STEAM GENERATOR C WATER LEVEL A
PCT 1 % = 1. 44" H20 0.0 100.0 UTUBES N/A p
3 AVERAGE - SEE SYSTEM DESCRIPTION STM GEN-BOTTOM AT 684 11 & TOP AT 82811 VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE.COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
WET Senses the water level in steam generator 2C.
The valid narrow range signals are averaged (3 signals if all are valid).
If none of the signals is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A SG LEVEL 3/C L2FW012A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE SG C WR LEVEL (YW) <>
STEAM GENERATOR C WATER LEVEL A
PCT 0 - 564" H20 0.0 100.0 TNKBOT N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT STEAM GENERATOR 2C VARIABLE NI DETECTOR PO\\IER SUPPLY CUT-OFF PO\\IER LEVEL:
N/A NI DETECTOR PO\\IER SUPPLY TURN-ON PO\\IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
WET UNIQUE SYSTEM DESC:
Senses the water level in steam generator 2C.
PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
. NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A SG PRESS 1/A P2MS001C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE SG A PRESSURE STEAM GENERATOR A PRESSURE A
PSIG N/A 0.0 1400.0 N/A N/A p
3 AVERAGE* SEE SYSTEM DESCRIPTION OUTPUT OF STM GEN A VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Provides pressure of the steam which is on route from steam generator 2A to the main steam manifold.
The valid wide range signals are averaged (3 signals if all are valid).
If none of the signals is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A SG PRESS 2/B P2MS002C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE SG B PRESSURE STEAM GENERATOR B PRESSURE A
PSIG N/A 0.0 1400.0 N/A N/A p
3 AVERAGE - SEE SYSTEM DESCRIPTION OUTPUT OF STM GEN B VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A
- Provides pressure of the steam which is on route from steam generator 28 to the main steam manifold.
The valid wide range signals are averaged (3 signals if all are valid).
If none of the signals is valid, this point is marked invalid.
PRINTED 09/05/91
DATE:
REACTOR UN IT :
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A SG PRESS 3/C P2MS003C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE SG C PRESSURE STEAM GENERATOR C PRESSURE A
PSIG N/A 0.0 1400.0 N/A N/A p
3 AVERAGE - SEE SYSTEM DESCRIPTION OUTPUT OF STM GEN C VARIABLE NI DETECTOR PO\\JER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR PO\\JER SUPPLY TURN-ON PO\\JER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Provides pressure of the steam which is on route from steam generator 2C to the main steam manifold.
The valid wide range signals are averaged (3 signals if all are valid).
If none of the signals is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
05/20/91 SU2 N/A STAB CLASS M3MM006A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PLANT SPEC POINT DESC:
SIGMA THETA (RCDR-6) (NL)
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\.I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
AIR STABILITY AT REACTOR SITE A
DEG N/A 0.0 45.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT PRIMARY TOWER TRAILER VARIABLE NI DETECTOR PO\\JER SUPPLY CUT-OFF PO\\.IER LEVEL:
N/A NI DETECTOR PO\\.IER SUPPLY TURN-ON PO\\JER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
The output sigma theta signal is the standard deviation around the average direction
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A STAB CLASS M3MM008A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE DELTA T (RCDR-9) (NL)
AIR STABILITY AT REACTOR SITE A
DEGC N/A
-5.0 15.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT 2 RTDs AT 35 1 & 150 1 ON PRIMARY TOWER VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR PO\\IER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Delta Tis lower t~rature minus upper t~rature.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
05/20/91 SU2 N/A STAB CLASS T3MM001A STATION: Surry UNIT: 2 P~R DATA POINT LIBRARY REFERENCE FILE AMB TEMPERATURE (RCDR-7) (NL)
AIR STABILITY AT REACTOR SITE A
DEGC N/A
-25.0 45.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT RTD AT 35 1 ON PRIMARY TOWER VARIABLE N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Measures air temperature at 35' elevation on the primary tower
- PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HO\\I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SLIZ N/A SUB MARGIN T2RC020C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FI.LE CORE EXIT TSAT MARGIN SATURATION TEMP - HIGHEST CET A
DEGF N/A
-35.000 200.0 N/A N/A p
2 AVERAGE - SEE SYSTEM DESCRIPTION TSAT - CONTAINMENT CET - REACTOR CORE VARIABLE NI DETECTOR PO\\IER SUPPLY CUT-OFF PO\\IER LEVEL:
N/A NI DETECTOR PO\\IER SUPPLY TURN-ON PO\\.IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A The valid saturation margin inputs from the RVLIS system are averaged (2 signals if all are valid).
If none of the signals are valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A TEMP CORE EX T2RC001C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE PEAK CORE EXIT TEMP HIGHEST TEMPERATURE AT CORE EXIT A
DEGF N/A 0.0 2400.0 N/A N/A p
50 MAXIMUM* SEE SYSTEM DESCRIPTION EXIT OF SELECTED FUEL ASSEMBLIES IN-CORE VARIABLE NI DETECTOR POlrlER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
N/A Monitors the reactor coolant exit temperature.
The highest valid incore thermocouple is used.
If none of the thermocouples is valid, this point is marked invalid
- PRINTED 09/05/91
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A WIND DIR M3MM004A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE WIND DIR LOWER (RCDR-4) (NL)
WIND DIR AT THE REACTOR SITE A
DEG N/A 0.0 360.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT 35 1 ON PRIMARY TOYER&30 1 ON BACKUP TOWER VARIABLE NI DETECTOR POYER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses wind direction at 35 feet.
PRINTED 09/05/91
---~--
~
DATE:
REACTOR UN IT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIG IT AL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A WIND DIR M3MM005A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE WIND DIR UPPER (RCDR-5) (NL)
WIND DIR AT THE REACTOR SITE A
DEG N/A 0.0 360.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT 150 1 ON PRIMARY TOWER VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Senses wind direction at 150 feet.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOl,I PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
05/20/91 SU2 N/A WIND SPEED M3MM002A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE WIND SPEED UPPER (RCDR-2) (NL)
WIND SPEED AT THE REACTOR SITE A
MPH N/A 0.0 100.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT 150 1 ON PRIMARY TOWER VARIABLE NI DETECTOR POl,IER SUPPLY CUT-OFF POl,IER LEVEL:
N/A NI DETECTOR POl,IER SUPPLY TURN-ON POl,IER LEVEL:
N/A INSTRUMENT FAILURE MODE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Measures wind speed at 150 feet.
PRINTED 09/05/91
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
09/05/91 SU2 N/A WIND SPEED M3MH001A STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE WIND SPEED LOWER (RCDR-1) (NL)
WIND SPEED AT REACTOR SITE A
MPH N/A 0.0 100.0 N/A N/A s
N/A N/A - THIS IS A DIRECT SENSOR INPUT 35 1 ON PRIMARY TOWER&30 1 ON BACKUP TOWER VARIABLE NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
N/A INSTRUMENT FAILURE HOOE:
N/A TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
N/A UNIQUE SYSTEM DESC:
Measures wind speed at 35 feet.