l '

1.0 DEF!HIT!ONS OEFINEO TERMS l.l The OEFINEO T[RMS of this section appear in capitalized type and are applicable throughout these Technical Sptcificat1ons.

ACT!ON l.Z ACTtON shall be that part of a specification which prescribes remedial measures required under designate<1 i:Dnditions.

AXIAL FLUX DIFFERENCE l.J A.'CIAL Fl.UX DIFFERENCE shall be the difference in normalized flux signals bet.,,..en the t09 and bottom halves of a two section ~core neutron detector.

CHANNEL CALISRATION

~~((\ ~ A CHANNEL CALISRATION shall be the adjust1111nt, H necessary, of tne A cnannel ~tput suc:h that it responds with the necessary range and ac:c:urac:y to lMO'lllfl values of the par11111t1r whid'I the channel lllOtl1tors. The CHANNEL CALIBRATION shall enc:Qlllpass the tnt1re channel 1nc:lud1ng the sensor and alarm and/or trip func:t1ons, and shall inc:lude the CHANNEL FUNCTIONAL TEST. The CHANNEL CALIBRATION 1111y be perfonned by any series of sequential, overlapping or total channel steps such that the tnt1rt channel is calibrated.

CHANNEL CHECX l.S A CHANNEL CHECX shall be th* qualitative assessintnt of channel behavior during operation by ooservation. This det1na1nat1on shall inc:lude, where possible, c:01119ar1son of th* d'lanne1 indication and/or status w1th other indications and/or status ci.rived frOll independent instrument channels measuring the same parainettr.

  • CHANNEL F\JHCTIONAL T!ST 1.6 A CHANNEL FUNCTIONAL TEST shall be the injection of a simulated signal into the channel as close to the prilftiry sensor as prac:t1c:able to verify OPERAS[L!TY fnc:lud1ng alarm and/or trip functions.

S.\L::! UN!i 1 1-1 Amendment No. 59 9606110285 960531 PDR ADOCK 05000272 p PDR

ACTION 19 - With the num.t:er of OPERABLE Char.r.e~s one less than the Total Number of Channels, STARTUP and/or POWER OPERATION may proceed provided the follcwir.g cc ~-cions are satisfied:

a. 7he ir.cperable channel is placed i~ the tr:.;;ed conditlon withln 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
b. The Minimum Channels OPERABLE requirements is met; however, the inoperable channel may be bypassed for up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> for surveillance testing of ocher channels per Specification 4.3.2.1.1.

ACTION 20 - With the number of OPERABLE channels cne less than the Total Number of Channels, restore the inoperable =hannel to OPERABLE status within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> er, be in at ~east HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in at least HOT SH~7~CWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />; however, one channe~ ~ay be bypassed for up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> for surveillance testing per Specification 4.3.2.l.l provided the other channel is OPERA3LE.

ACTION 21 - With the number cf OPERABLE channels one less than the Minimum Number cf Channels, operation may proceed provided thatf ie.i-ce_ I

~ /he Lncperable channel is restored to OPERABLE within 72 hours~

e. :f e:l='te affe::aei: Hair. :"ccet*.. at.:r ?drPtp .:.,3 e!e~ccceel: ea Se S'ti'C /
  • ef seF .. i:ee for ffiOre than 12 F.out s, -*.e Lllopet able c:.anz.el
i.li ji..u~~ered se as :o e.1aCle . . :.e :3-a . . '- Ci!r_:iic at c?1e

.'\1cu1il iaEy Fe:clnat.ei: ? ...... u!"'s a~c ...... Le l_.ss of cite ocher !"'lal.h Feeei*wate_ ?:111'1~.

ACTION 22 - NOT USED ACTION 23 - With the number of OPERABLE channels one less than the Total Number of Channels, restore the incperab~e channel to OPER.ll.8LE status *..1:.thin 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or te in HOT STANDBY W'ithin the 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and Ln at ~east H07 sr.~7:owN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

.; - - '- r:..e:--.-:::!::-.e:--.t. .......

~

Il\BLI ~ Al (CONTINUED)

ACCIDENT HQNITQRINO INSTRUHEHTl\TIOH REQUIRED HINIHUH IUrBUKIHT NO. OP CUANNILS NO. OP' CHl\NNELS ~CTIOH I

ll. PORV Block Valve Po*ltlon Indicator 2/valve** 1 1. 2

14. Pre**uriser Safety Val** Po*ition 2/valve** 1 1, 2 Indicator
15. Containment Pr***ur* - *arrow Rang* 2 1 1. 2
16. Containment Pr***ure - Wide Rang* 2 1 1, 2
17. Contain11ent Water Level - 2 1 w

w I

Wide Range

18. Core Sxit Th*rmK>Coupl** "4/cor* quadrant 2/core quadrant 1, 2

~

UI UI

19. !Reactor V****l Level ln*trumentatlon 2 1 By*t- (llVLIB)

~

(**) Total nUllber of channel* 1* con*idered to be two (2) with on* (1) of the channel* being any one (1) of th* followiRCJ alternate . .an* of deterainiRCJ PORV, PORV Block, or Saf*ty Valve po*itions Tailpipe T. . ?9ratur** for the yalve*, Pre**urls*r Relief Tank T. .peratur* Pr***urlEer Relief Tank Level OPERABLE.

c***) Action a r . . . ln* in eff*ct until *tartup from the 10th refueling outage at which time, PSE'G will in*tall the upgraded RVLIS. Upon expiration, Action* 1 and 2 will apply.

If

J I err.; J J-11 fconeipued)

IA!U: NOIAI!ON ACTION 6 Yith th* number of OPERA!I.E channels less than the Kinizzrwa Number of channels shown in Table 3.3-ll, restor* th* inoperable channel(s) to OPERABLE

  • e&tu.t within 7 days, or be in HOT SHUTDOYN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

ACTION 7 ~ith the number of OPERABLE channels one less than the Required Number of Channels shown in Table 3.3-ll, operation may proceed until the next CHANNEL CALIBRATION (which shall b* perform*d upon the next entry into MODE 5, COIJ) SHUTDOYN).

With the number of OPERABLE channels one less than f

the Required or Minimum number of channels shown in Tabl* 3.3*11, eith*r restore th* incp*rable channel(s) to OPERABLE status within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or:

l. Operation may proceed provid*d the Required Channels shown in Table 3.3*11 for the Reactor Coolant System Subcooling Margin Monitor and th* Core Exit Thermocouple* are OPERAILE.

With th* number of OPERABLE ch&nneb for the Reactor Coolant System Subcooling Margin Monitor and the Core Exit Thermocouple* shewn in Table 3.3-ll l*** than th* Required Number of Channels, follov the a**ociated action state11enc, and

2. R.Htore th* sysce11 to OPDABLE lt&tua at the next scheduled CHANN!L CALIBRATION (which
  • hall be performed upon th* next entry into MODE 5, COLD SHUTOOW).

SAL.EM

  • UNIT l 3/4 3*56a Amendment So. 117

f '

d. Salrce of waste arrl processin;J erployed (e.g., dewatered spent resin, a::mpact.ed dry waste, evaporator bott:.ans),
e. 'fype of container (e.g. , LSA, Type A, Type B, large ()Jantity) , arrl
f. solidification agent or absoi:bent (e.g., cement, urea fonnal.dehyde).

'Ihe Radioactive Effluent Rel.ease Reports shall incl00e a list of descriptioos of unplanned releases fran the site to UNRESllUCI'ID Am'AS of radioactive materials in qaseoos an:l liquid effluents made durin; the rep:irtin; pe.ricxi.

'Ihe Radioactive Effluent Release Reports shall incl00e acy ~ made durin;J the rep:>rt.irg pe.ricxi to the :m:x:ESS o:NlR)L ~ (:Ea>) an:l to the OFFSI'If:

IX:sE CAI.ClJIATICN MANUAL (OlXM), as wll as a listin; of new lcx::atialS for dose calculations anj/or environmental mnitorin; identified by the lan:l use census pursuant to Specification 3 .12. 2.

RADIAL mKrNG FAcroR LIMIT REFORI' 6.9.l.9 'Ihe F~ limits for P.ated 'lllenna.l Power (~) for all core planes cont:a.inin;J bank "D" control rods an:l all ~ core planes, an:l the plot of predict.ed heat flux hot dlannel factor times relative pa...ier (~*PRE!.) vs.

Axial Core Height With the limit envelope shall be provided to the NRC D"nlll"Pnt centrol Cesk with c:x:pies to the Reqiaal Administrator an:l the Resident Inspector. 'Ihe Report shall be provided to the Q:mniAAia1 l.lpCl'1 issuance.

In additiai, in the event that the limit shculd dlarge, requinn;r a new sut:mittal or sut:mittal of an amemed ~ Fact:cr Limit Report, it will be sut:mitted upc:ll issuarx:e.

6.9.2 Special Iep:n:ts shall be sut:mitted to the U.S. NUclear Regulatocy Q:mniSsiai, Doonnent Control Cesk, washin;ton, o.c. 20555, with a Ct:J1i1i to the Administrator, USNRC Reqiai I within the time pericxi specified for each IEpJrt.

6. 9. 3 ViolatialS of the requirements of the fire protectioo pio;z:am descrfrej.

in the 0¢ated Final Safety Anal}rsis Fef<ttt ~ch '#Olld have adversely affected the ability to achieve an:l maintain safe shutdcwn in the event of a fire shall be sut:mitted to the U. s. Nuclear Regulatory Crnmi ss ioo, rn:;, nnent caitrol Cesk, washin;ton, oc 20555, with a co;rt to the Reqiaal Administrator of the Regiaial Office of the NRC via the Licensee Event Report System within 30 days.

6-24 ~No.lw_

1.0 DEFINITIONS OE:: I NED iERMS 1.1 The DEFINED TC:RMS of this section appear in capitalized type and are appl~cable throughout these Technical Specifications.

ACTION l.2 ACTION shall be that part of a specification which prescribes. remedial measures required under designated conditions.

AXIAL FLUX DIFFERENCE 1.3 AXIAL FLUX DIFFERENCE shall be the difference in normalized flux signals between the top and bottom halves of a two section excore neutron detector.

CHANNEL CALIBRATION l.4't A CHANNEL CALIBRATION shall be the adjustment, as necessary, of the channel output such that it responds with the necessary range and accuracy to (nown values of the parameter which the channel monitors. The CHANNEL CALIBRATION shall encompass the entire channel including the sensor and ala~

and/or trip functions, and shall include the CHANNEL FUNCTIONAL TEST. The CHANNEL CALIBRATION may be performed by any series of sequential, overlapping or otal channel steps such that the entire channel is calibrated.

CHANNEL CHECK 1.5 A CHANNEL CHECK shall be the qualitative assessment of channel behavior during operation by observation. This determination shall include, where possible, comparison of the channel indication and/or status with other

~ndications and/or status derived from in~ependent instrument channels measuring the same parameter.

CHANNEL rUNCTIONAL TEST 1.6 A CHAN~EL FUNCTIONAL TEST shall be the injection of a simulated signal into the channel as close to the primary sensor as practicable to verify OPC::RABILITY including alarm and/or trip_ functions.

Amencrcen:

11 ,**

AC':'ION 19 - With the number of O?E?..ASLZ Channels cr.e le** than the :otal

~utru:er of Chanr.ala, S7ART~? and/er ?OWER O?!?..ATION ~Ay proceed prov~:ed t~e follow~ng ~=nd*:~ona are aatl*fied:

a. The Lr.operable chanr.el L* placed in the t:~p~d ccnditicn
  • .;i.thi.n 6 hcura.
  • i.  :'he M:ini:n~:n Chanr:els O?!:?..ASLZ req-..iL:e:ner.-::1 i.1 :Tiet; howeve:, tr.a ~r.cper3ol* channel may be bypaa*ed !er up to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> fer surveillance testing of other channel* per Specification 4.3.2.l.l.

ACTION 20 - With th* number of OP!RASLE Channel* one leaa than the Total Number of Channels, restore th* inoper&.ble channel to o~r.Lbl*

statu* within 6 hour* or, be in at leaat HOT STANDBY within th*

next 6 hour* and Ln at leaat HOT SHUTOOWN within th* followi.nq 6 hcur9; however, one channel may be bypaaaed !or up to 4 hour*

for gurvei:lance testLnq per Speci.!icati.on 4.3.2.l.l provided t~e other char.nel in O?ERASLZ.

ACT::ON 21 - ~ith the number of OPERAS~! channels one Lesg than the M:ini:num

~u~ber of Channe~g, cperati.on :nay proceed provi.ded tha:;e:tMe:.

~ ~rable channel i.s restored to OPE?..ASLE within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

~. If t~e *ffe~;ed Mai.A ree~wateF p~~p i* ex~eeted te ~* e~t

if ael'"JoO
a f;ir; ~;ir;a ;l:laA 7~ l=le~E*1 tl'l:e io.:cpera~l* cham.wl.

'* jY~per;ad ao 11 *o *~ab'a *"a i~a"; CiEs~i; gf tl=I*

1,1o1xi.J.i.;u"'l i'aedwater ? 11 mp* 11 pon 'oa* of t"* ot~ar ~a~n 1 i"aed"ater :f'"::ll?

ACTION 22 - ~/OT ':SEO AC':'::ON 23 - ~i..:h the number of O?E?..ABLE Chanr.els one ~es* than the !otai

~~~~er of Channels, :eg~ore :he l~cperable =hanr.el to O?ER>.SLZ stat~s within 48 hcurg or be i..n at least HOT 5711..'lDaY *.;i.thi.n 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and Ln HOT SHU7:0WN w~thl~ t~a follcwi~g 6 hcura.

3, ~ J-:3

TABLE l,l-11 (Contjnuedi ACCJPENT HONJTORING INSTRIJHENTATION REQUIRED HINIHUH u~nRUHENT NO. OF NO. OF CUl\NNILS CHANNELS

~TION 13 .. PORV Block Valve Po*ition Indicator 2/valve** l l ' 2

14. Preeeurizer Safety Valve Poeition Indicator 2/valve** 1 l ' 2
15. Containment Pre**ure - Narrow Range 2 1 l ' 2
16. Contail\llent Pree*ure - Wide Range 2 l 1, 2
17. Containment Water Level - Wide Range l

1, 2

18. Core Exit Thermocouple*

4/core quadrant 2/core quadrant l' 2

19. Reactor Veeeel Level ln*tru. . ntation 0

2 w Syeteaa (RVLIS)

I VI

/\

i/1 2

c** I Total nuaber of channel* i* con*idered to be two (2) with one (It of the channela being any one (lJ of the following alternate . . an* of deterainlng PORV, PORV Block, or Safety Valve pouition: Tailpipe T. . t>erature* for the valve*, Pr***uri&er Relief Tank Temperature Preaaurizer Relief Tank Level OPERABLE.

(**o) Action I r . . . in* in effect until etartup fro. the 6th refueling outage at which time, PSE'G will in*tall the upgraded RVLIS. Upon expiration, Action* l and 2 will apply.

z:

0

ACTICN 6

  • TABLS 3 J-11 tson;inued)

IABU: NOTATION

~ith the number of OPERABLE channdl£ less than the Minimum Number c-f c~anri~ls shown in Ta.bls 3. 3

  • l!., resi:ore t!":e inor:e*.:a.bl.e channel(s) to OPERABLE status within 7 c:Uys, or be in HOT SHL'1'DO~"'N within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

ACTION 7 ~ith the number of OPERABLE channels one less than the Required

~umber of Channels shown in Table 3.3-11, operation may proceed ur.til the next CHANNEL CALIBRATION (which shall be performed upon the next entry inco MODE 5, COLD SHUTOOIJN).

ACTION 8 ~ith the number of OPERABLE channels one less than the Required or Minimum number of channels shown in Table 3.3-11, either restore the inoperable channel(s) to OPERABLE status within 48 ho~rs or:

1. Ope.racion may proceed provided the Required Channels shown i:-.

Table 3.3-ll for the Reactor Coolant System Subcooling Margin Monitor and the Core Exit Thermocouples are OPERABLE. ~ith :he number of OPE.RABLE channels for th* React.or Cnolant System Subcooling Margin Monitor and the Core Exit Thermocouples shown in Table 3.3-11 less than the Required Number of Channels, follow the associated Action Statement, and

2. Restore the system co OPERABLE sc&cus at the next scheduled CHANNEL CALIBRATION (which shall be performed upon the next entry into MOOE S, COLD SHUTDOWN).

SAU.'i

  • UNIT 2 3/4 3-Slc Amendment No. 95

I l

d. So.lrce of waste an:i processin; ~loyed (e.g., dewatered spent resin, c:x::q:acted dry waste, evaporator OOtt.cms) , .
e. Type Of container (e.g. , I.SA, Type A, 'IYPe B, Large Quantity) , an::l
f. Solidification agent or absol':bent (e.g., cement, urea fomaldehyde).

'Ihe P.adioa.ctive Effluent Release Reports shall in:l.u::Je a list of descriptiais of unplanned releases fran the site to UNRES'm!CTm AREAS of radioactive materials in gaseaJS an:l liquid effluents made durin; the reportin; ~iod.

'Ihe P.adioa.ctive Effluent Release Reports shall in:l.l.D! any chan;es made durin3' the reportin; pericd to the ~ 'FSS a::Nm:>L ~ (PCP) an::i to the OFFSITE I:XlSE CAI.aJIATICll MANUAL (OLX:M), as well as a li.stin; of new locatiais for dose calcul.atic:ns anj/or environmental m:nitorin; identified by the larxi use census p.n:suant to Specificatiai 3.12.2.

RADIAL PE'AKlR? FAC!C2 LIMIT REBE' 6.9.1.9 'Ihe Fr/ limits for Rated 'lllemal Power (~) for all c::cre planes ccntainin:; bank "D" o:nt.rol rcx:1s an:l all unrocX3ed. core planes, and the plot of predicted heat flux hot channel factor times relative paiwer (~*PREI) vs.

Axial Core Height with the limit envelope shall be provided to the NRC D:x:nrrent O:introl Desk with cq>ies to the Regiaial Administrator an::i the Resident Inspector. '!be ~ shall be provided to the Q=mnj ssiai uµ::n issuarx:e.

In adiitian, in the event that the limit shc:W.d dlan;1e, recpirin; a new sul:mittal or sutmittal of an amen;1ed Peakin; Factor Limit Rep:lrt, it will be sul:mitted upcn issuan::e.

Sm:IAL~

6. 9. 2 sPecial iepoz:ts shall be sul:Jnitted to the u. s. Nllclear Regulatory Caini Bai.al, Document O:utrol Desk, Wclsh:in;tan, D. c. 20555, with a ccpy to the hhinist:ratcr, OSNPJ: Regiat I within the time pericd specified for each lq:orl:.
6. 9. 3 Violatiais of the requireDe1'lts of the fire prctectiai pio;z am described in the U'pjated Final Safety Analysis Rep:lrt which ~d have adversely affected the ability to adlieve an:i maintain safe srait.dclwn in the event of a fire shall be sutmitted to the U. s. Nuclear Regulatory O"mni ssiai, D.:x:nmmt Cc::rrt:rcl r:esk, wash.i.rqtal, oc 20555, with a c:x::py to the Regicnal ~tor of the Regiooal Office of the NRC via the Licensee Event ~t Systan within 30 days.

6-24 Ame rlment No. 11 7