Letter Sequence RAI |
---|
|
|
MONTHYEARML18066A1721998-06-0808 June 1998 Forwards Request for Addl Info Re Licensee Response to GL 92-01,rev 1,suppl 1.GL Requested Licensees Perform Review of Reactor Pressure Vessel Structural Integrity Assessments in Order to Identify,Collect & Rept Any New Data Project stage: RAI ML18066A2951998-09-0808 September 1998 Forwards Response to NRC 980608 RAI Re Rept CE NPSD-1039, Rev 2, Best Estimated Copper & Nickel Values in CE Fabricated Reactor Vessel Welds Project stage: Other ML18066A6441999-09-15015 September 1999 Informs That as Result of 980908 Response to RAI Re GL 92-01,Rev 1,Suppl,staff Revised Info in Rvid & Released Info as Rvid Version 2 Project stage: RAI 1998-09-08
[Table View] |
|
---|
Category:CORRESPONDENCE-LETTERS
MONTHYEARML18066A6871999-10-19019 October 1999 Forwards Response to NRC 990908 RAI Re Inservice Insp Program Relief Request 14.Ltr Contains No New Commitments & No Revs to Existing Commitments ML18066A6881999-10-19019 October 1999 Forwards Rev 5 to Palisades Nuclear Plant COLR, Per Requirements of TS 6.6.5.Ltr Contains No New Commitments & No Revs to Existing Commitments ML18066A6841999-10-13013 October 1999 Forwards Insp Rept 50-255/99-10 on 990812-0921.One Violation Noted Re Adherence to Radiological Protection Procedure Requirements.Violation Being Treated as Ncv,Consistent with App C of Enforcement Policy ML18066A6781999-10-0707 October 1999 Summarizes 991005 Meeting at Region III to Discuss Radiation Protection Program at Palisades.Topics Discussed Included Management Changes in Radiation Protection Program & Actions Taken to Correct Deficiencies Identified During 1998 Outage ML18066A6651999-10-0505 October 1999 Informs of Completion of Review of Palisades Plant 25-year Tendon Surveillance Rept & Associated post-surveillance Regression Analysis Submitted by Ltrs Dtd 971218,980223 & 980925.Forwards SE Supporting Performance of Surveillance ML18066A6721999-10-0404 October 1999 Forwards Operator Licensing Exam Rept 50-255/99-301(OL) for Initial Operator Licensing Exams at Palisades NPP Completed on 990614.Two RO Applicants & Two SRO Applicants Failed One or More Portions of Respective Exams & Were Denied Licenses ML18066A6741999-10-0202 October 1999 Forwards MOR for Sept 1999 for Palisades Nuclear Plant & Operating Data Rept Sheet for Month of Aug 1999.MOR for Aug 1999 Inadvertently Had Copy of Ref Data Sheet for Apr 1999 Data ML18066A6791999-10-0101 October 1999 Provides Response to RAI Re Draft Rept, Study of Air- Operated Valves in Us Nuclear Power Plants ML18066A6691999-09-30030 September 1999 Advises of Plans for Future Insp Activities at Facility for Opportunity to Prepare for Insps & to Provide Feedback on Any Planned Insps Which May Conflict with Plant Activities ML18066A6621999-09-30030 September 1999 Notifies NRC That Util Will Implement ITS at Plant on or Before Oct 31,2000 & Attachments 1 & 2 Contains Request for License Condition Which Relates First Performance of New or Revised Surveillance Requirements to Implementation of ITS ML18066A6601999-09-29029 September 1999 Forwards NRC Form 536,in Response to NRC Administrative Ltr 99-03, Preparation & Scheduling of Operator Licensing Examinations ML18066A6561999-09-28028 September 1999 Discusses Closeout of GL 97-04, Assurance of Sufficient Net Positive Suction Head for ECC & Containment Heat Removal Pumps. Understands That Util Will Address Concerns Raised by Insp Team at Future Date ML18066A6531999-09-23023 September 1999 Forwards Insp Rept 50-255/99-14 on 990831-0901.No Violations Noted.Insp Results Indicated with Crsd on-line (Non Outage) Planning & Scheduling Program Provided Effective Coordination & Established Appropriate Radiological Control ML18066A6471999-09-17017 September 1999 Forwards Final Clean Copies of ITS & Bases Pages Which Incorporate All Changes Proposed in Listed Ltrs.Clean Copies Also Incorporate Some Editorial Changes & Bases Clarifications as Result of Ongoing Reviews to LCOs ML18066A6441999-09-15015 September 1999 Informs That as Result of 980908 Response to RAI Re GL 92-01,Rev 1,Suppl,staff Revised Info in Rvid & Released Info as Rvid Version 2 ML18066A6431999-09-0808 September 1999 Informs That NRC Tentatively Scheduled Initial Licensing Exam for Operator License Applicants During Wk of 000522,in Response to Nl Haskell ML18066A6381999-09-0808 September 1999 Forwards Request for Addl Info Re ISI Program Relief Request 14 for Palisades Plant ML18066A6391999-09-0303 September 1999 Forwards Insp Rept 50-255/99-09 on 990522-0811.No Violations or Deviations Noted ML18066A6331999-09-0202 September 1999 Forwards Monthly Operating Rept for Aug 1999 & Revised Monthly Operating Rept for Apr 1999 for Palisades Nuclear Plant ML18066A6261999-08-26026 August 1999 Forwards Addl New Valve Relief Request as Alternative to Code Requirements That Will Provide Acceptable Level of Quality & Safety.Request Would Allow Use of App II, Check Valve Condition Monitoring Program, of ASME OM Code-1995 ML18066A6231999-08-26026 August 1999 Forwards SE Related to ISI Program Request for Relief ML18066A6091999-08-19019 August 1999 Provides Licensee with Individual Exam Results for Licensee Applicants Who Took June 1999 Initial License Exam.Without Encls ML20211D5661999-08-17017 August 1999 Forwards semi-annual Fitness for Duty Program Performance Rept for 990101-990630,IAW 10CFR26.71(d).Attachments 1 & 2 Summarize Test Results at Palisades Plant,Big Rock Point Plant & Corporate Ofc ML18066A6111999-08-13013 August 1999 Requests Exemption from Certain Requirements of 10CFR50,App R, Fire Protection Program for Nuclear Power Facilities Operating Prior to 790101. Request Concerns Oil Collection Sys Requirements for PCP Motors ML18066A6031999-08-0909 August 1999 Forwards SE Accepting Licensee Response to GL 96-05, Periodic Verification of Design-Basis Capability of Safety Related Movs, for Plant ML18066A5921999-07-30030 July 1999 Forwards Results of Review by Consumers Energy of Two NRC Draft Repts Entitled, Evaluation of Air-Operated Valves at Light-Water Reactors & Study of Air-Operated Valves in Us Nuclear Power Plants ML18066A5881999-07-30030 July 1999 Provides Rev to Instrument Channel Drift Measurement Submitted on 990611,in Response to NRC Comments on Util RAI Response for Sections 3.3,3.5 & 3.6 & Editorial Changes Revs Necessary for Consistency within ITS ML18066A5971999-07-30030 July 1999 Forwards Markup of Draft NRC SE Re Util Proposal to Convert to Its.Ltr Contains No New Commitments & No Revs to Existing Commitments ML20210G8351999-07-29029 July 1999 Final Response to FOIA Request for Documents.Records in App a Encl & Will Be Available in PDR ML18066A5801999-07-26026 July 1999 Discusses Evaluation of Relief Requests for ISI Re ASME Section Xi,Subsections IWE & Iwl.Staff Partially Denied Relief Request 1 on Basis That General Visual Exam in Lieu of VT-3 Exam.Relief Requests 4 & 6 Denied as Listed ML17191B4031999-07-23023 July 1999 Informs That NRC Plans to Administer GFE Section of Written Operator Licensing Exam on 991006.Ltr Should Be Submitted to Appropriate Regional Administrator at Listed Address to Register Personnel to Take GFE ML18066A5651999-07-19019 July 1999 Forwards Corrections to Previously Submitted TS Section 3.7, Plant Systems, Converting to Its,Per NUREG-1432.Licensee Realized That Certain Provisions of CTS Had Been Inappropriately Replaced with Provisions from STS ML18066A5481999-07-13013 July 1999 Forwards Draft SE Re Proposed Conversion to Its.Se Based on Review of Consumers Energy Co 980126 Application & as Supplemented by 980430,0914,1012,1109,990301,22,30,0407, 0503,0604,11 & 17 Ltrs ML18066A5381999-07-0808 July 1999 Forwards Insp Rept 50-255/99-08 on 990522-0630.No Violations Noted.Determined That Emergent Repairs to EDG Were Completed in Timely & Skillful Manner to Prevent Challenge to Plant Operation ML18066A5361999-07-0606 July 1999 Discusses 990629 Meeting with PRA Staff Re Initiatives in Risk Area & to Be Establish Dialog Between SRAs & PSAs Staff ML18066A5111999-06-29029 June 1999 Provides Voluntary Confirmation of Facility Readiness as Outlined in GL 98-01,Suppl 1, Y2K Readiness of Computer Sys at Npps. Disclosure & Response Encl ML20209B2081999-06-29029 June 1999 Discusses Closure of Response to RAI Re GL 92-01,Rev 1,Suppl 1, Reactor Vessel Structural Integrity. Rvid,Version 2 Issued as Result of Review of Responses.Info Should Be Reviewed & Comments Submitted by 990901 ML20210G8791999-06-23023 June 1999 FOIA Request for All Document Communications Between NRC & Region III Involving R Landsman,B Jorgensen & R Caniano & NRC Staff Under Their Supervision & All Communications in Their Possession to & from Consumers Power Re Plant ML18066A5061999-06-17017 June 1999 Forwards Responses to NRC Questions for ITS LCOs 3.6.3 & 3.6.6 of 990126 Submittal.One Editorial Change in Addition to Those Made in Response to NRC Comments & Conforming Changes Made to Associated Bases,Encl ML18066A4991999-06-11011 June 1999 Forwards Responses to NRC Comments Re ITS Section 3.3 & Associated Revs to ITS Sections 1.0,3.3,3.4 & 3.9 of 990126 ITS Conversion Submittal.One Technical Change & Several Editorial Changes Unrelated to NRC Comments,Also Provided ML18066A4921999-06-0909 June 1999 Discusses Response of 980226 Violation Re Insp Rept 50-255/97-18 Re Failure to Take Adequate Corrective Action. Ltr Contains New Commitments & No Rev ML18068A6011999-06-0808 June 1999 Forwards Description of Recent Changes Made to Palisades Site Emergency Plan,Excluding Minor & Editorial Changes Not Requiring Further Explanation ML18066A4851999-06-0404 June 1999 Forwards Insp Rept 50-255/99-04 on 990410-0521.No Violations Noted.Radiation Dose Received During Outage Was Significantly Less than Projected Because of Radiological Personnel Efforts to Create Heightened Awareness ML18066A4881999-06-0404 June 1999 Provides Responses to NRC Questions & Associated Editorial Revs for ITS LCOs 3.6.1,3.6.2,3.6.4,3.6.5 & 3.6.7 of 980126 Submittal.Responses to Comments on Remaining Section 3.6 LCOs Will Be Submitted Separately ML18066A4811999-06-0303 June 1999 Forwards Insp Rept 50-255/99-06 on 990506-12.Three Violations of NRC Requirements Occurred & Being Treated as non-cited Violations,Consistent with App C of Enforcement Policy ML18066A4731999-05-24024 May 1999 Informs That Region III Received Fema,Region V Ltr Transmitting FEMA Final Exercise Rept for 981201 Plume Exposure Pathway Exercise.No Deficiencies Identified, However,Seven Areas Requiring Corrective Actions Identified ML18066A4801999-05-24024 May 1999 Forwards Copy of Rev to NPDES Permit Number MI0001457 Renewal Application as Submitted to Mi Dept of Environ Quality on 990513 ML18066A4681999-05-19019 May 1999 Forwards Insp Rept 50-255/99-05 on 990503-06.Determined That Violation Occurred & Being Treated as Non-Cited Violation. Insp Focused on Whether Activities Associated with GL 96-05 Were Sufficient to Ensure Continued Capability of MOVs ML18066A4721999-05-18018 May 1999 Informs That During Period from 981101-990430,there Were No NPDES Permit Violations & No Repts of Oil,Salt or Polluting Matl Losses Were Made to Govt Agencies ML18066A4651999-05-17017 May 1999 Forwards ISI Program Relief Request 14 for NRC Approval in Accordance with 10CFR50.55(a)(3) as Requirement for Which Proposed Alternative Provide Acceptable Level of Quality & Safety.Rev 0 to SIR-99-032 Rept Also Encl 1999-09-08
[Table view] Category:OUTGOING CORRESPONDENCE
MONTHYEARML18066A6841999-10-13013 October 1999 Forwards Insp Rept 50-255/99-10 on 990812-0921.One Violation Noted Re Adherence to Radiological Protection Procedure Requirements.Violation Being Treated as Ncv,Consistent with App C of Enforcement Policy ML18066A6781999-10-0707 October 1999 Summarizes 991005 Meeting at Region III to Discuss Radiation Protection Program at Palisades.Topics Discussed Included Management Changes in Radiation Protection Program & Actions Taken to Correct Deficiencies Identified During 1998 Outage ML18066A6651999-10-0505 October 1999 Informs of Completion of Review of Palisades Plant 25-year Tendon Surveillance Rept & Associated post-surveillance Regression Analysis Submitted by Ltrs Dtd 971218,980223 & 980925.Forwards SE Supporting Performance of Surveillance ML18066A6721999-10-0404 October 1999 Forwards Operator Licensing Exam Rept 50-255/99-301(OL) for Initial Operator Licensing Exams at Palisades NPP Completed on 990614.Two RO Applicants & Two SRO Applicants Failed One or More Portions of Respective Exams & Were Denied Licenses ML18066A6691999-09-30030 September 1999 Advises of Plans for Future Insp Activities at Facility for Opportunity to Prepare for Insps & to Provide Feedback on Any Planned Insps Which May Conflict with Plant Activities ML18066A6561999-09-28028 September 1999 Discusses Closeout of GL 97-04, Assurance of Sufficient Net Positive Suction Head for ECC & Containment Heat Removal Pumps. Understands That Util Will Address Concerns Raised by Insp Team at Future Date ML18066A6531999-09-23023 September 1999 Forwards Insp Rept 50-255/99-14 on 990831-0901.No Violations Noted.Insp Results Indicated with Crsd on-line (Non Outage) Planning & Scheduling Program Provided Effective Coordination & Established Appropriate Radiological Control ML18066A6441999-09-15015 September 1999 Informs That as Result of 980908 Response to RAI Re GL 92-01,Rev 1,Suppl,staff Revised Info in Rvid & Released Info as Rvid Version 2 ML18066A6431999-09-0808 September 1999 Informs That NRC Tentatively Scheduled Initial Licensing Exam for Operator License Applicants During Wk of 000522,in Response to Nl Haskell ML18066A6381999-09-0808 September 1999 Forwards Request for Addl Info Re ISI Program Relief Request 14 for Palisades Plant ML18066A6391999-09-0303 September 1999 Forwards Insp Rept 50-255/99-09 on 990522-0811.No Violations or Deviations Noted ML18066A6231999-08-26026 August 1999 Forwards SE Related to ISI Program Request for Relief ML18066A6091999-08-19019 August 1999 Provides Licensee with Individual Exam Results for Licensee Applicants Who Took June 1999 Initial License Exam.Without Encls ML18066A6031999-08-0909 August 1999 Forwards SE Accepting Licensee Response to GL 96-05, Periodic Verification of Design-Basis Capability of Safety Related Movs, for Plant ML20210G8351999-07-29029 July 1999 Final Response to FOIA Request for Documents.Records in App a Encl & Will Be Available in PDR ML18066A5801999-07-26026 July 1999 Discusses Evaluation of Relief Requests for ISI Re ASME Section Xi,Subsections IWE & Iwl.Staff Partially Denied Relief Request 1 on Basis That General Visual Exam in Lieu of VT-3 Exam.Relief Requests 4 & 6 Denied as Listed ML17191B4031999-07-23023 July 1999 Informs That NRC Plans to Administer GFE Section of Written Operator Licensing Exam on 991006.Ltr Should Be Submitted to Appropriate Regional Administrator at Listed Address to Register Personnel to Take GFE ML18066A5481999-07-13013 July 1999 Forwards Draft SE Re Proposed Conversion to Its.Se Based on Review of Consumers Energy Co 980126 Application & as Supplemented by 980430,0914,1012,1109,990301,22,30,0407, 0503,0604,11 & 17 Ltrs ML18066A5381999-07-0808 July 1999 Forwards Insp Rept 50-255/99-08 on 990522-0630.No Violations Noted.Determined That Emergent Repairs to EDG Were Completed in Timely & Skillful Manner to Prevent Challenge to Plant Operation ML18066A5361999-07-0606 July 1999 Discusses 990629 Meeting with PRA Staff Re Initiatives in Risk Area & to Be Establish Dialog Between SRAs & PSAs Staff ML20209B2081999-06-29029 June 1999 Discusses Closure of Response to RAI Re GL 92-01,Rev 1,Suppl 1, Reactor Vessel Structural Integrity. Rvid,Version 2 Issued as Result of Review of Responses.Info Should Be Reviewed & Comments Submitted by 990901 ML18066A4851999-06-0404 June 1999 Forwards Insp Rept 50-255/99-04 on 990410-0521.No Violations Noted.Radiation Dose Received During Outage Was Significantly Less than Projected Because of Radiological Personnel Efforts to Create Heightened Awareness ML18066A4811999-06-0303 June 1999 Forwards Insp Rept 50-255/99-06 on 990506-12.Three Violations of NRC Requirements Occurred & Being Treated as non-cited Violations,Consistent with App C of Enforcement Policy ML18066A4731999-05-24024 May 1999 Informs That Region III Received Fema,Region V Ltr Transmitting FEMA Final Exercise Rept for 981201 Plume Exposure Pathway Exercise.No Deficiencies Identified, However,Seven Areas Requiring Corrective Actions Identified ML18066A4681999-05-19019 May 1999 Forwards Insp Rept 50-255/99-05 on 990503-06.Determined That Violation Occurred & Being Treated as Non-Cited Violation. Insp Focused on Whether Activities Associated with GL 96-05 Were Sufficient to Ensure Continued Capability of MOVs ML18068A5951999-05-13013 May 1999 Informs That NRC Ofc of NRR Reorganized,Effective 990328. Forwards Organization Chart ML18068A5771999-04-23023 April 1999 Forwards Insp Rept 50-255/99-03 on 990226-0409.No Violations Noted.However,Weaknesses in Cold Weather Preparations Identified by Inspectors ML18066A4591999-04-21021 April 1999 Informs That,Based on Determinations That Changes in Rev 15 Do Not Decrease Effectiveness of Plant EP & That Plan Continues to Meet Stds of 10CFR50.47(b) & Requirements of App E to Part 50,NRC Approval Not Required ML18066A4491999-04-0808 April 1999 Informs That Meeting to Discuss Results of Plant Performance Review Process Scheduled for 990428 ML18066A4511999-04-0707 April 1999 Discusses 990401 Telcon Re Palisades Improved TSs Review Schedule.Encl Table Provides Agreed Upon Milestone Dates for Completion of Review & Reflects Proposed Amend Request Date of 990830 ML18066A4461999-03-26026 March 1999 Advises of Planned Insp Effort Resulting from Palisades PPR Review,Which Was Completed on 990203.Overall Performance at Palisades Was Acceptable IR 05000255/19980221999-03-22022 March 1999 Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-255/98-22 Issued on 990210.Corrective Actions Will Be Examined During Future Insps ML18068A5431999-03-17017 March 1999 Forwards RAI Re Licensee 980126 Request to Convert Palisades Nuclear Plant Current TSs to Improved Tss.Response Requested by 990430 ML18068A5381999-03-0505 March 1999 Forwards Insp Rept 50-255/99-01 on 990112-0225.No Violations Noted ML18066A4071999-02-10010 February 1999 Forwards Insp Rept 50-255/98-22 on 981126-990112 & Nov. Violation Identified Re Failure to Submit Engineering Analysis Pertaining to Degraded Studs on Primary Coolant Pump ML18066A4111999-02-10010 February 1999 Ack Receipt of ,Which Transmitted Changes Identified as Rev 42 to Plant Security Plan Submitted Under Provisions of 10CFR50.54(p).No NRC Approval Required IAW 10CFR50.54 ML20203F2541999-02-10010 February 1999 Informs That Beginning 990216,DE Hills Will Be Chief of Operations Branch Which Includes Operator Licensing Function ML18066A4061999-02-10010 February 1999 Informs That Requested Response Was Provided by Licensee on 980707 & That According to Nudocs,Document Should Be Available in Pdr.Informs That Staff Issued Evaluation of Licensee Response to USI A-46 by Ltr ML18068A5221999-02-10010 February 1999 Confirms 990208 Telcon Between R Bailey & R Frigo Re Arrangements Made for Administration of Licensing Exams at Palisades Facility Weeks of 990607 & 0614.NRC Will Make Exam Validation Visit to Facility Week of 990524 ML18066A3991999-02-0505 February 1999 Forwards Insp Rept 50-255/99-02 on 990119-22 & Notice of Violation.Violation Involved Failure to Mark Two Security Procedures That Contained Protected Info (Safeguards Info) & to Properly Store Some Copies of One of Those Procedures ML17191B2221999-02-0202 February 1999 Informs That NRC Plans to Administer Gfes of Operator Licensng Exam on 990407.Authorized Facility Representative Must Submit Ltr to Appropriate Regional Administrator Identifying Individuals Taking Exam ML18066A3841999-01-29029 January 1999 Forwards Request for Addl Info Re TS Change Request to Convert to Improved TS for Plant.Mutually Agreeable Completion Date of 990331 Established ML18066A3851999-01-28028 January 1999 Forwards SE Accepting Licensee 981220 Request for Staff to Authorize Consumers Energy Proposed Alternative to Requirements of ASME Section XI Article IWA-5250 for Degraded P-50A Primary Coolant Pump Casing Bolts at Plant ML18066A3711999-01-12012 January 1999 Refers to Consumers Energy 981215 Response to 980731 RAI Re Proposed Fluence Calculation Methodology.Confirms Understanding That Based on Discussions at 981207 Meeting, Licensee Does Not Expect Further Review of Methodology ML18066A3601998-12-29029 December 1998 Forwards Emergency Preparedness Exercise Insp Rept 50-255/98-21 on 981130-1204.No Violations Noted.Objective of Insp to Determine Whether Palisades Emergency Plan Adequate ML18066A3571998-12-28028 December 1998 Forwards SE Authorizing Licensee 980313 Request to Use ASME OMa-1996,Subsection Istd, Preservice & Inservice Exam & Testing of Dynamic Restraints in Light Water Reactors, as Alternative to Requirements of ASME OMa-1988 Part 4 ML18066A3501998-12-15015 December 1998 Informs That as Part of PRA Implementation Plan, Commission Assigned Two SRAs to Each Regional Ofc.Sras Will Routinely Assess Licensee Event Repts,Plant Events,Insp Findings & EAs from Risk Perspective ML18066A3471998-12-14014 December 1998 Forwards Insp Rept 50-255/98-19 on 981008-1125.No Violations Noted.Noted That Weakness in Equipment Status Control Contributed to Incident That Inadvertently Drained Hydrazine Addition Tank to Turbine Building Sump ML18066A3431998-12-0404 December 1998 Forwards Request for Addl Info Re TSs Change Request to Convert to Improved TSs for Palisades Plant.Addl Info Needed in Sections 2.0,3.1 & 3.2.Response Requested 60 Days from Date Ltr Was Established ML18066A3461998-12-0202 December 1998 Advises of Planned Insp Effort for Next 6 Months at Plant. Info Provided to Minimize Resource Impact on Staff & to Allow for Scheduling Conflicts & Personnel Availability to Be Resolved in Advance of Inspector Arrival Onsite 1999-09-08
[Table view] |
Text
...
I) l UNITED STATES NUCLEAR REGULATORY COMMISSION
- Mr. Nathan L. Haskell Director, Licensing Palisades Plant 27780 Blue Star Memorial Highway Covert, Ml 49043 WASHINGTON, D.C. 20555--0001 September 15, 1999
SUBJECT:
PALISADES PLANT - RESPONSE TO THE REQUESTS FOR ADDITIONAL
-- ----INFORMAfiOl\\fREGARDING--GENERIC-tE'FfER 92-01-,-REVISIGN-1, r
i SUPPLEMENT 1, "REACTOR VESSEL STRUCTURAL INTEGRITY" (TAC NO.
MA0560)
Dear Mr. Haskell:
On May 19, 1995, the U.S. Nuclear Regulatory Commission (NRG) issued Generic Letter 92-01, Revision 1, Supplement 1 (GL 92-01, Rev. 1, Supp. 1 ), "Reactor Vessel Structural Integrity," to holders of nuclear operating licenses. The NRG issued the supplement to require addressees to:
(1) identify, collect and report any new data pertinent to the analysis of structural integrity of the reactor pressure vessels (RPVs) at their nuclear plants, and (2) assess the impact of that data on their RPV integrity analyses relative to the requirements
- of Sections 50.60 and 50.61 to Part 50 of Title 10 of the Code of Federal Regulations (10 CFR 50.60 and 10 CFR 50.61), and to the requirements of Appendices G and H to Part 50 of Title 1 O of the Code of Federal Regulations (Appendices G and H to 1 O CFR Part 50).
On August 17,
- 1995, you submitted your initial response to GL 92-01, Rev. 1, Supp. 1 and provided the requested information relative to the structural integrity assessments for the Palisades Plant. The NRG staff evaluated your response to GL 92-01, Rev. 1, Supp. 1, and provided its conclusion relative to your response on December 23, 1996. However, since the issuance of the staff's closure letter, the Combustion Engineering (CE) Owners Group and the
~()\\
J) *.
- Babcock and Wilcox (B&W) Owners Group have each submitted additional data regarding the alloying chemistries of beltline welds in CE-and B&W-fabricated vessels. The additional alloying data were submitted in Topical Reports CE NPSD-1039, Revision 2, CE NPSD-1119, Revision 1 (for CE-fabricated RPV welds), and BAW-2325, Revision 1 (for B&W-fabricated RPV welds). In addition, Chicago Bridge arid Iron (CB&I) boiling-water reactor (BWR) data were submitted in Topical Report BWRVIP-46. As a result of the efforts by CE and B&W, the staff determined that additional information was necessary relative to the structural integrity assessments for your plant. On June 8, 1998, the staff issued a request for additional information (RAI) in regard to the alloying chemistries of beltline welds, your assessment of surveillance data for your facility, pressure-temperature (P-T) limits, and pressurized thermal shock (PTS) assessments for the Palisades Plant. In general, with respect to the contents of the RAI, the staff requested that you reassess the alloying chemistries for the beltline welds and RPV surveillance welds relative to the chemistries provided in the applicable topical report, and provid.e the impact of any changes to the best-estimate chemistries for your beltline RPV welds 9909200227 990915 PDR ADOCK 05000255 p
PQR
.
, I
- J.)
I I
~}
. N. September 15, 1999 on the structural integrity asse.ssnients for your facility relative to the requirements of 1 O CFR 50.60, 1 o CFR 50.61, and Appendices G and H to 1 O CFR Part 50, as applicable to the licensing basis for your plant.
You provided your response to the staff's RAI for the Palisades Plant on September 8, 1998.
As a result of the staff's review of your responses to GL 92-01, Revision 1, GL 92-01, Rev. 1, Supp. 1, and the RAI, the staff has revised the information in the Reactor Vessel Integrity Database (RVID) and is releasing it a13 RVID Version 2.
The ~~~~d~~-;;diskettes areposteaon-the-World-Wide-W.eb_at_aJocation *which is linked to the NRC home page (http://www.nrc.gov/NRR/RVID/index.html ). W,e recommend-tllatyou---,----___:-~
review this information and provide any comments regarding the RVID data for your plant to the staff. No additional information is necessary with regard to the structural irit~grity assessments.
Future submittals on P-T limits, PTS, or upper shelf energy should reference the most current information.
This* closes the staff's efforts in reg~rp to.TAC No. MA0560. The staff appreciates your efforts in regard to this matter.
f __.. __.1' ' "'
~ *:
t'**_,,
O.rigiD.a1 -\\~~g~ed *by=*
1't_
J.. *::i *;;
1, I
. * :;. }; .,*:*
Robert,G. Schaa(Project Manager, Section 1
/.-
Sincerely, - ; : *
... **"... \\ '*.'.
.' *_ *, Project Direct9rate:lll'
'..:... *, * ~} *: :' ::_ -~, ~ *.-
- Divisio.n of'Licen~ing P,roje~t Managemel')t
~ \\ * : * *.*'
. Office 1:0f ~Liclear Reactor' Regulation Docket No*. 50-255 ~-.-'* --. *;'
-~ /': :- -~.. ~1.; ~* ~ _,, )i ~-'J."o' * **- ;
. * *' /:
cc: See next page r'... Distribut.iPO.. _ *--"*
- ,.. D9cketE11e.. (50:.255)
(/PUBLIC R. Schaaf ACRS A. \\/egel, Riii
~ *.,
~-
r'
' 't, i,'
_ 1 J 1.
l :~ ~ ' ¥:~,*' '*, '
' ;:1 '
I..
" 1 *
,,_~ ',:~\\-
1~
._ ~\\
~~~~;- <<-~>:.
..:*-.. ~.......
'..:,A*:,
- r PDlll-1 r/f R. Bouling OGC
- *. -*.;: j,
" ~
l,
~:
A.' Lee
'.;. -.,....... ~ '. '_,
DOCUMENT NAME: G:\\PDlll-1\\Palisades\\ltra0560.wpd r,::To=re=c=elv=e=a =co~===========::::=::;::=;:::::.=======~=:::::;::=;:::::::====:=::=::====::=::;;with attachmenVenclosure "N" =No copy OFFICE PM:PD31 NAME DATE OFFICIAL RECORD COPY
r
- N. September 15, 1999 on the structural integrity assessments for your facility relative to the requirements of 1 O CFR 50.60, 10 CFR 50.61, and Appendices G and H to 10 CFRPart 50, as applicable to the licensing basis for your plant.
You provided your response to the staff's RAI for the Palisades Plant on September 8, 1998.
As a result of the staff's review of your responses to GL 92-01, Revision 1, GL 92-01, Rev. 1, Supp. 1, and the RAI, the staff has revised the information in the Reactor Vessel Integrity
IJatabase-(F-lVID-)_and~J~asing it as RVID Version 2.
The new database diskettes are posted on the World Wide webatalocation-which-is-linkedJo __
the NRC home page (http://www.nrc.gov/NRR/RVID/index.html ). We recommend.that you review this information and provide any comments regarding the RVID data for your plant to the staff. No additional information is necessary with regard to the structural integrity assessments.
Future submittals on P-T limits, PTS, or upper shelf energy should reference the most current information.
This closes the staff's efforts in regard to TAC No. MA0560. The staff appreciates your efforts
. in regard to this matter.
Docket No. 50-255 cc: See next page.
Distribution Docket File (50-255)
PUBLIC R. Schaaf ACRS A. Vegel, Riii PDlll-1 r/f R. Bouling OGC A. Lee Sincerely, Original signed by:
Robert G. Schaaf, Project Manager, Section 1 Project Directorate Ill Division of Licensing Project Management Office of ~uclear Reactor Regulation DOCUMENT NAME: G:\\PDlll-1\\Palisades\\ltra0560.wpd ri=To=re=ce=lve==::::a c=o~of=th=ls=d=oc=um=e=nt=,
ln=d=lcat=iei==ln::th:;=e:::::bo=:x:::: *=c*===Co==:=::;:=::;==::=:==:::::::==::=::;~wlth *anachmenVanclosure "N" =No copy OFFICE PM:PD31 NAME
.DATE OFFICIAL RECORD COPY
'f
.. --- -**----------- ------------------***.. ------*- -*-----*-- -- ~- -*-*-----------******..
N. on the structural integrity assessments for your facility relative to the requirements of 1 O CFR 50.60, 10 CFR 50.61, and Appendices G and H to 10 CFR Part 50, as applicable to the licensing basis for your plant.
You provided your response to the staff's RAI for the Palisades Plant on September 8, 1998.
As a result of the staff's review of your responses to GL 92-01, Revision 1, GL 92-01, Rev. 1,
- -------S_uR~_1, and the RAI, the staff has revised the information in the Reactor Vessel Integrity Database(RVIDtand-is-releasing_ita~JWID Version 2.
The new database diskettes are posted on the World Wide Web at a location wnictfis-linked-to------
the NRC home page (http://www.nrc.gov/NRR/RVID/index.html ). We recommend that you review this information and provide any comments regarding the RVID data for your plant to the staff. No additional information is necessary with regard to the structural integrity assessments.
Future submittals on P-T limits, PTS, or upper shelf energy should reference the most current information.
This closes the staff's efforts in regard to TAC No. MA0560. The staff appreciates your efforts in regard to this matter.
Docket No. 50-255 cc: See next page Sincerely,
~1.4-/
Robert G. Schaaf, Project Manager, Section 1 Project Directorate Ill Division of Lice_nsjng Project Management Offic::e of Nuclear ~eactor Regulation
Mr. Nathan L. Haskell Consumers Energy Company cc:
Mr. Thomas J. Palmisano Site Vice President Palisades Plant 27780 Blue Star Memorial Highway Palisades Plant Drinking Water and Radiological Protection Division Michigan Department of
...:__Covert, Michigan 49043 Environmental Quality 3423 N. Martin Luther King Jr Blvd Mr. Robert A. Fenech, Sr Vice Pres
p~0:-Box-3063_0_G_l:>_!i_ty1ail~oom Nuclear, Fossil, and Hydro Operations Lansing, Michigan 48909-8f3o----------
Consumers Energy Company 212 West Michigan Avenue Jackson, Michigan 49201 Arunas-T. Udrys, Esquire Consumers Energy Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region Ill U.S. Nuclear Regulatory Commission 801 Warrenville Road
- Lisle, Illinois 60532-4351 Je~ry 'Sarno, Supervisor Covert.Towns~ip P. 0. Box 35 Covert, Michigan 49043 Office of the Governor P. 0. Box 30013 Lansing, Michigan 48909 U.S. Nuclear Regulatory Commission Resident Inspector's Office Palisades Plant
- 27782 Blue Star Memorial Highway Covert, Michigan 49043 Michigan Department of Attorney General Special Litigation Division 630 Law Building P.O. Box 30212 Lansing, Michigan 48909 August 1998