ML18066A656

From kanterella
Jump to navigation Jump to search

Discusses Closeout of GL 97-04, Assurance of Sufficient Net Positive Suction Head for ECC & Containment Heat Removal Pumps. Understands That Util Will Address Concerns Raised by Insp Team at Future Date
ML18066A656
Person / Time
Site: Palisades 
Issue date: 09/28/1999
From: Robert Schaaf
NRC (Affiliation Not Assigned)
To: Haskell N
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
References
GL-97-04, TAC-MA0021, NUDOCS 9910040053
Download: ML18066A656 (5)


Text

{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION Mr. Nathan L. Haskell Director, Licensing Palisades Plant *., 27780 Blue Star Memorial Highway Covert, Ml 49043 WASHINGTON, D.C. 2055$-0001 September 28, 1999

SUBJECT:

PALISADES PLANT-CLOSEOUT OF GENERIC LEITER 97-04, "ASSURANCE OF SUFFICIENT NET POSITIVE SUCTION HEAD FOR EMERGENCY CORE COOLING AND CONTAINMENT HEAT REMOVAL PUMPS" (TAC NO. MA0021) I

Dear Mr. Haskell:

On October 7, 1997, the U.S. Nuclear Regulatory Commission issued Generic Letter (GL) 97-04, "Assurance of Sufficient Net Positive Suction Head for Emergency Core Cooling, and Containment Heat Removal Pumps," to all holders of operating licenses or construction permits. Consumers Energy Company provided its response to GL 97-04 on January 5, 1998. We issued a request additional information (RAI) about the response on July 2, 1998. -You responded to our RAI on August 3, 1998. During the weeks of July 6 and July 20, 1998, an.Engineering and Technical Support Inspection Team identified two concerns with the GL 97-04 response, as documented in Inspection Report 50-255/98012. Specifically, the team was concerned that containment spray pump P-54A and high-pressure safety injection pump P-66A had inadequate net positive ~ suction head (NPSH) available for a short period during pump suction switchover at the / initiation of the accident.recirculation phase. The team also concluded that there was . insufficient information in the GL 97-04 response to substantiate the conclusion that pump operation in this manner was acceptable. The team's second concern involved apparent discrepancies in the supporting analysis. ) To address the first concern, you stated in your August 3, 1998, letter that additional discussions were -held with the pump manufacturers. Based on these discussions, the manufacturers forwarded additional documentation to you confirming that the pumps would continue to operate and deliver flow for several minutes until the required NPSH is met through proceduralized operator actions. ( 9910040053 990928

  • f.. *'PDR * * :;ADOCK 05000255
1.

' -p * * :

  • PDR 1;,~1 I

l i I I I

N. '( The staff has reviewed the submittals for the Palisades Plant. Based on this review, we believe that you have provided the information requested by GL 97-04. We understand that you will address the concerns raised by the inspection team at a future date. Based on the information provided, we consider GL 97-04 closed for the Palisades Plant. Docket No. 50-255 cc: See next page Sincerely, ~1.91-{ Robert G. Schaaf, Project Manager, Section 1

  • Project Directorate Ill Division of Licensing Project Management Office of Nuclear Reactor Regulation

Mr. Nathan L. Haskell _*,Consumers Energy Company cc: Mr. Thomas J. Palmisano Site Vice President Palisades Plant 27780 Blue Star Memorial Highway \\ Covert, Michigan 49043 Mr. Robert A. Fenech, Sr Vice Pres Nuclear, Fossil, and Hydro Operations Consumers Energy Company 212 West Michigan Avenue Jackson, Michigan 49201 Arunas T. Udrys, Esquire Consumers Energy Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region Ill U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, Illinois 60532-4351 Jerry Sarno, Supervisor Covert Township. P. 0. Box 35 Covert, Michigan 49043 Office of the Governor P. 0. Box 30013 Lansing, Michigan 48909 U.S. Nuclear Regulatory Commission Resident Inspector's Office Palisades Plant 27782 Blue Star Memorial Highway Covert, Michigan 49043 J / Palisades Plant Drinking Water and Radiological Protection Division Michigan Department of Environmental Quality 3423 N. Martin Luther King Jr Blvd P. 0. Box 30630 CPH Mailroom . Lansing, Michigan 48909-8130 Michigan Department of Attorney General Special Litigation Division 630 Law Building P.O. Box 30212 Lansing, Michigan 48909 August 1998

N. September 28, 1999 The staff has reviewed the submittals for the Palisades Plant. Based on this review, we believe that you have provided the information requested by GL 97-04. We understand that you will address the concerns raised by the inspection team at a future date. Based on the information provided, we consider GL 97-04 closed for the Palisades Plant Docket No. 50-255 cc: See next page DISIRIBUJ"ION

  • r

~

  • -...__!?._9ctet E1le/

PUBLIC ACRS K. Kavanagh .. ~ Sincerely, Original signed by: Robert G. Schaaf, Project Manager, Section 1 Project Directorate Ill Division of Licensing Project Management Office of Nuclear Rea.ctor Regulation I I.* 'J ~ ** * .-: *r. ~

    • -~

~\\- - ':* ') , r"* ,*/, , ~. I* DOCUMENT NAME: G:\\PDlll-1\\Palisades\\ltra0021.wpd

  • No major changes To receive a co of th ls* document, Indicate In the box: *c* = Co without attachmenUenclosure "E" = Co with attachmenUenclosure "N" = No copy OFFICE PM:PD31 SC:SPLB E

NAME GHubbard* DATE 8/20/99 OFFICIAL RECORD COPY

N. September 28, 1999 The staff has* reviewed the submittals for the Palisades Plant. Based on this review, we believe that you have provided the information requested by GL 97-04. We understand that you will address the concerns raised by the inspection team at a future date. Based on the information provided, we consider GL 97-04 closed for the Palisades Plant. Docket No. 50-255 cc: See next page DISTRIBUTION Docket File PUBLIC ACRS K. Kavanagh PDlll-1 r/f OGC A. Vegel, Riii Sincerely, Original signed by: Robert G. Schaaf, Project Manager, Section 1 Project Directorate Ill Division of Licensing Project Management Office of Nuclear Reactor Regulation DOCUMENT NAME: G:\\PDlll-1\\Palisades\\ltra0021.wpd

  • No major changes To receive a co of this document, Indicate In the box: *c* = Co with attachmenVenclosure "N" = No copy OFFICE. PM:PD31 SC:SPLB SC:PD31,:,..,

E NAME GHubbard* CCrai 1 \\1. '***- DATE 8/20/99 r I

  • i'...:* /99 OFFICIAL RECORD COPY}}