Jump to navigation Jump to search
Forwards Insp Rept 50-255/99-14 on 990831-0901.No Violations Noted.Insp Results Indicated with Crsd on-line (Non Outage) Planning & Scheduling Program Provided Effective Coordination & Established Appropriate Radiological Control
ML18066A653
Person / Time
Site: Palisades Entergy icon.png
Issue date: 09/23/1999
From: Shear G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Thomas J. Palmisano
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
Shared Package
ML18066A654 List:
References
50-255-99-14, NUDOCS 9910010371
Download: ML18066A653 (2)


See also: IR 05000255/1999014

Text

. .

September 23, 1999

Mr. Thomas J. Palmisano

Site Vice President and General Manager *

Palisades Nuclear Generating Plant

27780 Blue Star Memorial Highway

Covert, Ml 49043-9530

SUBJECT:

NRC RADIATION PROTECTION INSPECTION REPORT 50-255/99014(DRS)

Dear Mr. Palmisano:

On September*1, 1999, the NRC completed an inspection at your Palisades Nuciear

Generating Plant. The enclosed report presents the results of that inspection. No violations of

NRC requirements were identified.

.

.

The inspection examined activities conducted under your license related to radiation safety and

to compliance with the Commission's rules and regulations and with the conditions of your

license. Specifically, this inspection reviewed the Chemical and Radiological Services

Department's (CRSD) on-line planning and scheduling program and the CRSD involvement in

the planning and scheduling of the refueling outage scheduled to begin in October 1999: The

inspection also included a review of the planned Nuclear Performance Assessment Department

(NPAD) oversight of CRSD performance during the outage and a tour of the facility. To this

end, the inspection consisted of a selective examination of representative procedures and

records, observations and interviewswith plant personnel.

Our inspection results indicated that the CRSD's on-line (non outage) Planning and Scheduling

Program provided effective coordination and .established appropriate radiological control

provisions over on-line work activities. The CRSD also appeared to be effective in ensuring

that radiation protection issues and As-Low-As-Reasonably-Achievable (ALARA) controls were

integrated into the planning and scheduling of the 1999 refueling outage. In addition, the

Nuclear Performance Assessment Department's planned oversight of CRSD activities during

the 1999 refueling outage was well planned and of sufficient scope to assess the performance

of the radiation protection program.

In accordance with 10 CFR 2.790 of the NRC's "Rules and Practice," a copy of this letter and its

enclosure will be placed in the NRC Public Document Room .

9910010371 990923

PDR

ADOCK 05000255

0

PDR

1---

\\

.

T. Palmisano

-2-

We will gladly discuss any questions you have concerning this inspection.

Sincerely,*

Oriqinal Signed by Gary L. Shear

Gary L. Shear, Chief

Plant Support Branch

Docket No. 50-255

License No. DPR-20

Enclosure:

cc w/encl:

Inspection Report 50-255/99014(DRS)

R Fenech, Senior Vice President, Nuclear,

Fossil and Hydro Operations

N. Haskell, Director, Licensing

R. Whale, Michigan Public Service Commission

Michigan Department of Environmental Quality

Department of Attorney General (Ml) .

Emergency Management Division, Ml Department

of State Police

Distribution:

CAC (E-Mail)

RPC (E-Mail)

RGS (Project Mgr.) (E-Mail)

J. Caldwell, Riii w/encl *

B. Clayton, Riii w/encl

SRI Palisades w/encl

DRP w/encl

DRS w/encl

  • Riii PRR w/encl

PUBLIC IE-01 w/encl

Docket File w/encl *

GREENS

IEO (E-Mail)

DOCDESK (E-Mail)

DOCUMENT NAME: G:/DRS/PAL99014.DRS

OFFICE

.Riii

t

Riii

NAME

DNelson:*

GShear

DATE

09/- .1 /99

09/ t--/99

with attachmenVendosure ".N" = No co

OFFICIAL RECORD CO Y