ML17284A621

From kanterella
Jump to navigation Jump to search
Informs That Licensee Plans to Continue to Participate in Joint Owners' Group MOV Periodic Verification Program as Member of Bwrog,In Response to GL 96-05
ML17284A621
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 05/20/1998
From: Bemis P
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
GL-96-05, GL-96-5, GO2-98-088, GO2-98-88, NUDOCS 9805290066
Download: ML17284A621 (3)


Text

CATEGORY 1 REGULATO INFORMATION DISTRIBUTION ~ STEM (RIDS)

ACCESSION NBR:9805290066 DOC.DATE: 98/05/20 NOTARIZED: NO DOCKET FACIL:50-397 WPPSS Nuclear Project, Unit 2, Washington Public Powe 05000397 AUTH. NAME, , AUTHOR AFFILIATION BEMIS,P.R. Washington Public Power Supply System RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Informs that licensee plans to continue to participate in Joint Owners'roup MOV periodic verification program as C member of BWROG,in response to GL 96-05.

A DISTRIBUTION CODE: A073D COPIES RECEIVED:LTR i ENCL M SIZE:

TITLE: GL-96-05 Periodic Verif. of Design Basis Capability of Safety-Related~

NOTES: E REC1PIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD4-2 PD POSLUSNY,C INTERNAL: AC AEOD/SOD/RAB TLE CENTER, 1 NRR/DE/EMEB

~REANSEN, A RES/DET/EIB/B RES/DST RES/DST/PRAB EXTERNAL: NOAC NRC PDR D

U E

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED: LTTR 12 ENCL

WASHINGTON PUBLIC POWER SUPPLY SYSTEM P.O. Box 968 ~ Richland, Washington 99352-0968 May 20, 1998 G02-98-088 Docket No. 50-397 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:

Subject:

WNP-2 OPERATING LICENSE NPF-21 RESPONSE TO SAFETY EVALUATION-JOINTOWNERS'ROUP PROGRAM ON PERIODIC VERIFICATIONOF MOTOR-OPERATED VALVES (IN RESPONSE TO GENERIC LETTER 96-05)

References:

1) Safety Evaluation on Joint Owners'roup Program on Periodic Verification of Motor-Operated Valves Described in Topical Report NEDC-32719, Revision 2, dated October 30, 1997
2) Generic Letter 96-05, "Periodic Verification of Design Basis Capability of Safety-Related Motor-Operated Valves," dated September 18, 1996 On October 30, 1997, the Nuclear Regulatory Commission issued the reference 1) Safety Evaluation (SE), which within the conditions and limitations described in the SE, stated that the Staff considers the Joint Owners'roup (JOG) Program on Motor-Operated Valve Periodic Verification an acceptable industry-wide response to Generic Letter (GL) 96-05.

The JOG had agreed that after the issuance of the SE, requests would be made for participating utilities to notify the NRC of their plans to implemerit the JOG Program on Periodic Verification of Motor-Operated Valves, (i.e., NEDC-32719, Revision 2) and that any deviations from the JOG program would be justified.

By this letter, the Supply System is providing the requested response. The Supply System plans to continue to participate in the JOG Motor-Operated Valve Periodic Verification Program as a member of the Boiling Water Reactor Owners'roup and plans to implement the program elements described in Topical Report NEDC-32719, Revision 2.

II I

9805250066 98052011 PDR ADOCK 0500Q397 P PDRJ

~

>age Two RESPONSE TO SAFETY EVALUATION-JOINTOWNERS'ROUP PROGRAM ON PERIODIC VERIFICATIONOF MOTOR-OPERATED VALVES (IN RESPONSE TO GENERIC LETTER 96-05)

If you have questions or require further information please contact me or Doug Coleman at (509) 377-4563.

esp lly P.. Bemis (Mail Drop PE23)

Vice President, Nuclear Operations CC: EW Merschoff - NRC RIV KE Perkins, Jr. - NRC WCFO C Poslunsy, Jr. - NRR NRC Sr. Resident Inspector - 927N DL Williams - BPA/399 PD Robinson - Winston & Strawn