|
---|
Category:NPDES NONCOMPLIANCE NOTIFICATION
MONTHYEARML17241A4851999-10-0101 October 1999 NPDES Noncompliance Notification:On 990906 & 07,19 Dead Green Sea Turtles Recovered from Unit 1 Intake Well.Cause Not Presently Known.Capture Efforts Increased Behind 5 Inch Net Until Remaining Turtles Recovered ML17241A4391999-08-13013 August 1999 NPDES Noncompliance Notification:On 990717,dead Loggerhead Turtle Was Recovered from Plant Intake Canal.Caused by Lowered 5-inch Barrier Net.Net Was Cleaned of Accumulated Algae & Raised Into Position on 990719.With 990813 Ltr ML17229B0301999-03-0101 March 1999 NPDES Noncompliance Notification:On 990207,dead Green Turtle (Chelonia Mydas) Weighing 7.5 Lb Recovered from Plant Intake Canal.Caused by Shoaling of Sediments in Canal Where Capture Net Deployed.Methods of Capture Net Insp Modified ML17229A8711998-10-0101 October 1998 NPDES Noncompliance Notification:On 980903,08,14 & 18 Differential Pressure Across Intake Travelling Screens Occurred.Caused by Excessive Jellyfish Buildup.Secured 1A1 Cw Pump & Throttled Three of Four Cw Pumps ML17229A8111998-07-23023 July 1998 NPDES Noncompliance Notification:On 980717,discovered That 15 Juvenile Least Terns Died in Roof Drainage Sys at Plant Screens Placed Around Drains Earlier in Nesting Season to Protect Hatchlings from Entering Drain Gutters ML17229A5821998-01-0808 January 1998 NPDES Noncompliance Notification:On 971214,discovered Partially Entangled Mantee in Sea Turtle Capture Nets.Caused by Large Openings in Concrete Velocity Caps.Addl Insp of Caps Will Be Made ML17229A5001997-10-17017 October 1997 NPDES Noncompliance Notification:On 970912 Samples Were Taken for CBOD5 at Influent & Effluent of St Lucie Unit 1 Sewage Treatment Plant.Value Less than Permitted Minimum Due to Increased Number of Personnel.Resample Taken ML17229A3981997-07-0707 July 1997 NPDES Noncompliance Notification:On 970614 & 30,discovered One Dead Sea Turtle on Each Date.Caused by five-inch Barrier Net Loaded W/Algae.Removed Algae from Net & Hand Drudged Silt to Allow Net to Return to Original Position ML17229A0651996-10-10010 October 1996 Noncompliance Notification:On 960918,adult Female West Indian Manatee Observed in Intake Canal.Newly Installed Turtle Barrier Net Was Instrumental in Retaining Manatee in Safe Location & in Good Condition.Manatee Released ML17228B5761996-07-23023 July 1996 NPDES Noncompliance Notification:On 960603,effluent Ph of Unit 1 Sewage Treatment Plant Observed to Be 4.03 Std Units. Util Believes Increased Numbers of Personnel at Site During Refueling Outage Resulted in Extra Loading ML17228B4581996-04-0505 April 1996 Unusual or Important Environ Event Re Fish Kill in Plant Intake Canal on 960311.Caused by Extreme Seawater Turbidity Associated W/Storm Conditions,Clogging Gill Surfaces & Suffocating Fish.Well Chlorination Discontinued ML17228B3391995-11-24024 November 1995 NPDES Noncompliance Notification:On 951016,effluent Ph of Unit 1 Sewage Treatment Plant Observed to Be 5.54 Std Units,Below 6.0 Std Units Required by Wastewater Permit. Increased Ph Monitoring of Aeration Tanks Undertaken ML17228A9501994-12-0808 December 1994 NPDES Noncompliance Notification:On 941204,2 Millon Gallons of Untreated Parking Lot Runoff Entered Mangrove Impoundment 008E.Aluminum Sheet Pile Will Be Driven Several Inches in Front of Wall ML17228A9341994-11-18018 November 1994 NPDES Noncompliance Notification:On 941116,untreated Parking Lot Runoff Escaped to Mangrove Impoundment 008E.FP&L Engineering Examining Failure Mode for Event & Will Design Appropriate Mod.Temporary Repairs to Be Completed by 941130 ML17228A9091994-11-0404 November 1994 NPDES Noncompliance Notification:On 941030,1.5 Million Gallons of Untreated Parking Lot Runoff Entered Mangrove Impoundment 008E.Permanent Corrective Actions Under Review ML17228A3561993-11-0101 November 1993 NPDES Noncompliance Notification:On 930915,midnight Discharge Canal Sample Collected During Biocide Application Indicated Concentration of 0.53 Ppm.Communications Between Individuals Involved Increased ML17228A2081993-07-0606 July 1993 NPDES Noncompliance Notification:On 930503,sewage Treatment Plant Effluent Tested & Found to Have Ph Value of 3.6 Std Units.Util Believes That Acidic Solution Mistakenly Poured Down Plant Drain.Sodium Carbonate Added to Sys ML17227A8021993-04-14014 April 1993 NPDES Noncompliance Notification:Sea Turtle Captures in Intake Canal Increased Dramatically Beginning in Fall 1992. During First Quarter 1993,165 Turtles Removed from Canal. Mods to Ocean Intake Velocity Caps Completed in Feb 1992 ML17227A7601993-03-0505 March 1993 NPDES Noncompliance Notification:On 930114,neutralization Basin,Containing 220,000 Gallons of Water,Discharged to Intake Canal at Ph of 10.20 Std Units.Caused by Miscommunication.Procedure Developed to Address Discharge ML17227A6891993-01-14014 January 1993 NPDES Noncompliance Notification:On 921221,chemical Feed Tank Inadvertently Discharged Through Drain Left in Open Position,Resulting in Release of Approx 20 Gallons of Amerzine to West Storm Pond.Personnel Counseled ML17227A6051992-09-22022 September 1992 NPDES Noncompliance Notification:On 920826,time Allowed for Condenser Chlorination Exceeded.Caused by Human Error. Operating Procedure Re Hypochlorite Sys Operation Revised, Operations Light Order Issued & Chlorination Log Revised ML17227A5201992-07-17017 July 1992 NPDES Noncompliance Notification:On 920714,discovered Loss of Pump Suction on Hydrazine Chemical Feed Sys Tanks, Resulting in Discharge of 72 Lbs of Hydrazine to Storm Drain Sys.Caused by Open Drain Valve.Investigation Underway ML17227A4731992-06-24024 June 1992 NPDES Noncompliance Notification:On 920507,effluent Ph of Sewage Treatment Plant Noted Below 6.0 Std Units Required by NPDES Permit.Sodium Carbonate Added & Average Flow from Sewage Plant Diluted by Circulating Water Flow ML17309A6791992-06-0505 June 1992 NPDES Noncompliance Notification:On 920409,between 920501-07 Inadvertent Release of Hydrazine to Onsite East Stormwater Basin Detected.Caused by Need to Drain Sg.Operating Procedures Will Be Modified to Ensure Full Control ML17223B2671991-09-24024 September 1991 NPDES Noncompliance Notification:On 910831,West Indian Manatee Observed in Intake Canal.Fl Dept of Natural Resources Observed Animal to Be in No Immediate Danger. Animal Taken to Zoo in Tampa,Fl for Observation & Treatment ML17223B2431991-08-12012 August 1991 NPDES Noncompliance Notification:On 910715,at Least Two Terns Found in Site Evaporation/Percolation Ponds & Died. Util Evaluating Feasibility of Installing Oily/Water Separator on Turbine Lub Oil Sump ML17223A8831990-08-10010 August 1990 NPDES Noncompliance Notification:On 900616,main Condenser Chlorinated Twice for 220 Minutes Exceeding Permit Limit. Procedure Modified to Allow Only Chemistry Personnel to Alter or Move Signs Indicating Order of Chlorination ML17223A6721990-05-20020 May 1990 NPDES Noncompliance Notification:On 900317 & 18,chlorination Discontinued W/O Collecting Required Samples for Free Available Oxidants at Point of Discharge.Instructions for Weekend Collections Will Be Defined to Prevent Recurrence ML17223A5851990-03-13013 March 1990 NPDES Noncompliance Notification:On 900212,fishkill Observed in Intake Canal of Plant.Caused by Depletion of Dissolved O2.In Event of Closure of 16 Ft Diameter Ocean Intake Pipe, Sluice Gate Will Be Gradually Raised Assuring Adequate O2 ML17223A3591989-10-16016 October 1989 NPDES Noncompliance Notification:On 890803 & 04,plant Discharge Canal Temp Exceeded 113 F Limit.Unit 1 down- Powered to Clean Condenser Water Boxes ML17223A2301989-05-31031 May 1989 NPDES Noncompliance Notification:On 890517 & 25,iron Concentration from Radwaste Batch Discharge Exceeded Max Concentration Limit.Source of Iron in Effluent Stream Under Investigation ML20247F5211989-05-11011 May 1989 NPDES Noncompliance Notification:On 890309,effluent Ph of Unit 1 Sewage Treatment Plant Observed to Be 3.6 Std Units. Unknown Quantity of Effluent W/Ph Less than 6.0 Std Units Discharged.Sodium Carbonate Added to Correct Ph to 6.2 ML17222A6161988-11-14014 November 1988 NPDES Noncompliance Notification:On 881021,10,000 Gallons of Ph 10.4 Water Released Into Intake Canal.Caused by Pipe Break in Valve Pit.Plant Work Order Issued to Repair Pipe ML17219A3131987-01-15015 January 1987 NPDES Noncompliance Notification:Max Temp Rise Limitation Exceeded in Aug 1986.Caused by Failure of Circulating Water Pump & Condenser Fouling ML20083L6261984-04-0606 April 1984 NPDES Noncompliance Notification:On 840217,high Discharge Canal Water Levels Experienced While Using Multiport Diffuser Under Certain Plant Operating Conditions.Cause Not Stated.Multiport Diffuser Discharge Sys Inspected 1999-08-13
[Table view] Category:TEXT-ENVIRONMENTAL REPORTS
MONTHYEARML17241A4851999-10-0101 October 1999 NPDES Noncompliance Notification:On 990906 & 07,19 Dead Green Sea Turtles Recovered from Unit 1 Intake Well.Cause Not Presently Known.Capture Efforts Increased Behind 5 Inch Net Until Remaining Turtles Recovered ML17241A4391999-08-13013 August 1999 NPDES Noncompliance Notification:On 990717,dead Loggerhead Turtle Was Recovered from Plant Intake Canal.Caused by Lowered 5-inch Barrier Net.Net Was Cleaned of Accumulated Algae & Raised Into Position on 990719.With 990813 Ltr ML17229B0301999-03-0101 March 1999 NPDES Noncompliance Notification:On 990207,dead Green Turtle (Chelonia Mydas) Weighing 7.5 Lb Recovered from Plant Intake Canal.Caused by Shoaling of Sediments in Canal Where Capture Net Deployed.Methods of Capture Net Insp Modified ML17241A3621998-12-31031 December 1998 Revised Attachment C, Results from Interlaboratory Comparison Program 1998, of 1998 Annual Radiological Environmental Operating Rept. ML17229B1091998-12-31031 December 1998 1998 Annual Environ Operating Rept for St Lucie Unit 2. ML17229B0781998-12-31031 December 1998 1998 Annual Radiological Environ Operating Rept for St Lucie Plant Units 1 & 2. with 990331 Ltr. Pages 8 of 12 Through 12 of 12 in 2nd,3rd & 4th Quarters of Incoming Submittal Not Included ML17229B0351998-12-31031 December 1998 Combined Annual Radioactive Effluent Release Rept for Period Jan-Dec 1998. ML17229B0231998-12-31031 December 1998 1998 Std Format for Reporting Number of Personnel & Man-Rem for Work & Job Functions. ML17229A8711998-10-0101 October 1998 NPDES Noncompliance Notification:On 980903,08,14 & 18 Differential Pressure Across Intake Travelling Screens Occurred.Caused by Excessive Jellyfish Buildup.Secured 1A1 Cw Pump & Throttled Three of Four Cw Pumps ML17229A8111998-07-23023 July 1998 NPDES Noncompliance Notification:On 980717,discovered That 15 Juvenile Least Terns Died in Roof Drainage Sys at Plant Screens Placed Around Drains Earlier in Nesting Season to Protect Hatchlings from Entering Drain Gutters ML17229A5821998-01-0808 January 1998 NPDES Noncompliance Notification:On 971214,discovered Partially Entangled Mantee in Sea Turtle Capture Nets.Caused by Large Openings in Concrete Velocity Caps.Addl Insp of Caps Will Be Made ML17229A6941997-12-31031 December 1997 1997 Annual Environ Operation Rept, for St Lucie,Unit 2 ML17229A6371997-12-31031 December 1997 Combined Annual Radioactive Effluent Release Rept for Period 970101-1231. ML17229A5001997-10-17017 October 1997 NPDES Noncompliance Notification:On 970912 Samples Were Taken for CBOD5 at Influent & Effluent of St Lucie Unit 1 Sewage Treatment Plant.Value Less than Permitted Minimum Due to Increased Number of Personnel.Resample Taken ML17229A3981997-07-0707 July 1997 NPDES Noncompliance Notification:On 970614 & 30,discovered One Dead Sea Turtle on Each Date.Caused by five-inch Barrier Net Loaded W/Algae.Removed Algae from Net & Hand Drudged Silt to Allow Net to Return to Original Position ML17229A2451996-12-31031 December 1996 1996 Man-Rem Rept. W/970224 Ltr ML17229A2431996-12-31031 December 1996 Combined Annual Radioactive Effluent Release Rept for Period 960101-1231. ML17309A8851996-12-31031 December 1996 1996 Annual Radiological Environ Operating Rept. W/970411 Ltr ML17309A8841996-12-31031 December 1996 1996 Annual Environ Operating Rept. W/970417 Ltr ML17229A0651996-10-10010 October 1996 Noncompliance Notification:On 960918,adult Female West Indian Manatee Observed in Intake Canal.Newly Installed Turtle Barrier Net Was Instrumental in Retaining Manatee in Safe Location & in Good Condition.Manatee Released ML17228B5761996-07-23023 July 1996 NPDES Noncompliance Notification:On 960603,effluent Ph of Unit 1 Sewage Treatment Plant Observed to Be 4.03 Std Units. Util Believes Increased Numbers of Personnel at Site During Refueling Outage Resulted in Extra Loading ML17228B4581996-04-0505 April 1996 Unusual or Important Environ Event Re Fish Kill in Plant Intake Canal on 960311.Caused by Extreme Seawater Turbidity Associated W/Storm Conditions,Clogging Gill Surfaces & Suffocating Fish.Well Chlorination Discontinued ML17228B4681995-12-31031 December 1995 1995 Annual Radiological Environ Operating Rept St. Lucie Plant,Units 1 & 2. W/960412 Ltr ML17228B4231995-12-31031 December 1995 Corrected 1995 Annual Radioactive Effluent Release Rept. ML17228B4051995-12-31031 December 1995 1995 Annual Operating Rept, Including Primary Chemistry Info,Mangrove Photographic Survey Results & Man-Rem Rept.W/ 960222 Ltr ML17309A8241995-12-31031 December 1995 Annual Radiological Effluent Release Rept. W/960228 Ltr ML17309A8291995-12-31031 December 1995 1995 Annual Radiological Environ Operating Rept St Lucie Plant Units 1 & 2. W/960321 Ltr ML17309A8341995-12-31031 December 1995 Annual Environ Operating Rept. W/960423 Ltr ML17228B3321995-11-30030 November 1995 Assessment of Impacts of St Lucie Nuclear Generating Plant on Sea Turtle Species Found in Nearshore Waters of Florida. ML17228B3391995-11-24024 November 1995 NPDES Noncompliance Notification:On 951016,effluent Ph of Unit 1 Sewage Treatment Plant Observed to Be 5.54 Std Units,Below 6.0 Std Units Required by Wastewater Permit. Increased Ph Monitoring of Aeration Tanks Undertaken ML17228B1321994-12-31031 December 1994 Annual Environ Operating Rept 1994 - Vol I. ML17228B1331994-12-31031 December 1994 Annual Environ Operating Rept (FPL-94),Vol Ii. ML17309A7841994-12-31031 December 1994 1994 Annual Radiological Environ Operating Rept St Lucie Plant Units 1 & 2. W/950419 Ltr ML17228A9501994-12-0808 December 1994 NPDES Noncompliance Notification:On 941204,2 Millon Gallons of Untreated Parking Lot Runoff Entered Mangrove Impoundment 008E.Aluminum Sheet Pile Will Be Driven Several Inches in Front of Wall ML17228A9341994-11-18018 November 1994 NPDES Noncompliance Notification:On 941116,untreated Parking Lot Runoff Escaped to Mangrove Impoundment 008E.FP&L Engineering Examining Failure Mode for Event & Will Design Appropriate Mod.Temporary Repairs to Be Completed by 941130 ML17228A9091994-11-0404 November 1994 NPDES Noncompliance Notification:On 941030,1.5 Million Gallons of Untreated Parking Lot Runoff Entered Mangrove Impoundment 008E.Permanent Corrective Actions Under Review ML17228A4771993-12-31031 December 1993 Personnel Radiation Monitoring Rept CY93, 1993 man-rem Rept Required by Reg Guide 1.16,submitted in 1993 Annual Operating rept.W/940302 Ltr ML17309A7331993-12-31031 December 1993 Annual Environ Operating Rept 1993, Vols 1 & 2.W/940426 Ltr ML17309A7311993-12-31031 December 1993 1993 Annual Radiological Environ Operating Rept St Lucie, Units 1 & 2. W/940420 Ltr ML17309A7251993-12-31031 December 1993 Combined Semiannual Radioactive Effluent Release Rept for Period Jul-Dec 1993. W/940228 Ltr ML17228A6121993-12-31031 December 1993 Correction to 1993 Semi-Annual Radioactive Effluent Release Rept & Response to Brookhaven Natl Lab Request for Info ML17228A3561993-11-0101 November 1993 NPDES Noncompliance Notification:On 930915,midnight Discharge Canal Sample Collected During Biocide Application Indicated Concentration of 0.53 Ppm.Communications Between Individuals Involved Increased ML17228A2081993-07-0606 July 1993 NPDES Noncompliance Notification:On 930503,sewage Treatment Plant Effluent Tested & Found to Have Ph Value of 3.6 Std Units.Util Believes That Acidic Solution Mistakenly Poured Down Plant Drain.Sodium Carbonate Added to Sys ML17309A7081993-06-30030 June 1993 Combined Semiannual Radioactive Release Rept for Jan-June 1993 for St Lucie Plant,Units 1 & 2. W/930826 Ltr ML17227A8021993-04-14014 April 1993 NPDES Noncompliance Notification:Sea Turtle Captures in Intake Canal Increased Dramatically Beginning in Fall 1992. During First Quarter 1993,165 Turtles Removed from Canal. Mods to Ocean Intake Velocity Caps Completed in Feb 1992 ML17227A7601993-03-0505 March 1993 NPDES Noncompliance Notification:On 930114,neutralization Basin,Containing 220,000 Gallons of Water,Discharged to Intake Canal at Ph of 10.20 Std Units.Caused by Miscommunication.Procedure Developed to Address Discharge ML17227A6891993-01-14014 January 1993 NPDES Noncompliance Notification:On 921221,chemical Feed Tank Inadvertently Discharged Through Drain Left in Open Position,Resulting in Release of Approx 20 Gallons of Amerzine to West Storm Pond.Personnel Counseled ML17227A7061992-12-31031 December 1992 1992 Man-Rem Rept. ML17227A7051992-12-31031 December 1992 Statistical Whole Body Monitoring Rept for CY92. ML17309A6961992-12-31031 December 1992 Combined Semiannual Radioactive Effluent Release Rept for Jul-Dec 1992. W/930226 Ltr 1999-08-13
[Table view] |
Text
ACCEI ERAT DOCU1MXNT DIST UTION SYSTEM lg REGULA Z INFORMATION DISTRIBUTIO YSTEM (RIDS)
ACCESSION NBR:9307140239 DOC.DATE:.93/07/06 NOTARIZED: NO DOCKET FACIL:50 335 St. Lucie Plant, Unit 1, Florida Power & Light Co. 05000335 AUTH.NAME AUTHOR AFFILIATION SAGER,D.A. Florida Power & Light Co.
RECIP.NAME RECIPIENT AFFILIATION R Document Control Branch (Document Control Desk)
SUBJECT:
NPDES noncompliance notification:on 930503,sewage treatment plant effluent tested & found to have pH value of 3.6 std units. Util believes that acidic solution mistakenly poured D down plant drain. Sodium carbonate added to sys.
DISTRIBUTION CODE: IE23D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: Environmental Event Report (per Tech Specs)
NOTES RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-2 LA 3 3 PD2-2 PD D 1 1 NORRIS,J 1 1 D
INTERNAL: ACRS 5 5 NRR/DRSS/PEPB 1 1 NRR/Pb@S ILRB 1 1 OGC/HDS3 1 1 RE LE 01 1 1 RGN2 1 1 EXTERNAL: NRC PDR 1 1 NSIC 1 1 D
D D
NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTEI CONTACT THE DOCUMENT CONTROL DESK, ROOM P1-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED: LTTR 17 ENCL 17 il
< Jbl'
0 0 P.O. Box 28, Ft. Pierce, FL N954-0128 July 6, 1993 L-93-134 10 CFR 50.36b 10 CFR 50.4 EPP 3.2.1 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re: St. Lucie Unit 1 Docket Nos. 50-335 Deviation of the NPDES Permit On May 3, 1993, the effluent pH of the Unit 1 Sewage Treatment Plant was observed to be 3.60 standard units which is below the 6.0 standard units required by the National Pollutant Discharge Elimination System (NPDES) Permit. This deviation is being reported to the Environmental Protection Agency in the Monthly Discharge Monitoring Report. A copy of the event is attached and is being sent pursuant to Section 3.2.1 of the St. Lucie Unit 1 Environmental Protection Plan.
Should you have any questions on this information, please contact us. 4 Very truly yours, D. A.
Vice St L DAS:JJB:kw
'l ger r sident t
cc: Stewart D. Ebneter, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant Attachment DAS/PSL N919-93 4 BAAL <
9307240239 930706 PDR ADQCK 05000335 8 PDR an FPL Group company
~ /p i
4 I ~ gvv.
"i,gb 0
.~. ~ <J ~.g I
E
Florida Power L Light Company - St. Lucie Plant NPDES Permit No. FL0002208 Outfall Serial Number: 004-1 Monitoring Period: May 1 - May 31, 1993
¹ On Monday, May 3, 1993, at 8:30 AM, the St. Lucie Plant Unit 1 Sewage Treatment Plant (STP) effluent was tested and found to have a pH value of 3.6 Standard Units (SU) ~
FPL believes that an acidic solution was mistakenly poured down a plant drain causing the depressed pH value in the STP effluent. A sample, previously collected on Friday, April 30, 1993, at 8:30 AM was within the specified limit for pH. Therefore, the event appears to have occurred vier the weekend.
Upon discovering the STP effluent situation, corrective action was initiated immediately by adding sodium carbonate to the system. By 9:25 AM the effluent pH had returned within permit limits of 6.0 to 9.0 SU. During this event, flow in the intake/discharge canal, which receives the STP effluent, was 500,00 gallons per minute. Therefore, no adverse effect on the environment was observed or is expected.
Equipment has been purchased to continuously monitor the influent pH to the STP.
When installed, this type of excursion can be avoided by taking corrective action to neutralize the system before the pH of the effluent from the STP is outside the effluent limits. The source of this pH excursion has been investigated and will be addressed through the plant's chemical control program. Corrective action has included memos written to all departments who have been issued acids. These departments were reminded of the proper methods for disposal of acidic solutions.