ML17229A243

From kanterella
Jump to navigation Jump to search
Combined Annual Radioactive Effluent Release Rept for Period 960101-1231
ML17229A243
Person / Time
Site: Saint Lucie  
Issue date: 12/31/1996
From:
FLORIDA POWER & LIGHT CO.
To:
Shared Package
ML17229A242 List:
References
NUDOCS 9703040371
Download: ML17229A243 (73)


Text

FLORIDAPOWER 8 LIGHTCOMPANY ST. LUCIE PLANT UNITS NO. 1 8 2 LICENSE NUMBERS DPR-67 & NPF-16 COMBINEDANNUALRADIOACTIVEEFFLUENT RELEASE REPORT FOR THE PERIOD JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 970304037i 970224 PDR ADOCK 05000335 R

PDR

TABLEOF CONTENTS DESCRIPTION PAGE EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION.

VISITOR DOSE RESULTS FOR CALENDARYEAR 1996 OFFSITE DOSE CALCULATIONMANUALREVISIONS SOLID WASTE AND IRRADIATEDFUEL SHIPMENTS PROCESS CONTROL PROGRAM REVISIONS LIQUIDEFFLUENTS:

Summation of all Releases Summation of all Releases Nuclide Summation by Quarter Nuclide Summation by Quarter Liquid Effluent Dose Liquid Effluent Dose GASEOUS EFFLUENT:

Unit ¹1 Unit¹ 2 Unit¹1.

Unit¹2 Unit ¹1.

Unit¹2 7

9 11 15 19 20 Summation of all Releases Summation of all Releases Nuclide Summation by Quarter Nuclide Summation by Quarter Gas Effluent Dose Gas Effluent Dose Unit ¹1 Unit¹ 2 Unit¹1.

Unit¹ 2 Unit¹1.

Unit¹ 2 21 23 25 29 33 34 SOLID WASTE DISPOSAL - TABLE 3.9 Shipment Summations............

SOLID WASTE DISPOSAL - TABLE3.10 Sewage Sludge Shipments...

Attachment - A UNPLANNEDGaseous Release of August 14, 1996.....

Attachment - B C-200 ODCM Revision 35 40 41 43

0

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORIVIATION

1. Regulatory Limits 1.1 For Liquid Waste Effluents A. The concentration of radioactive material released from the site shall be limited to ten times the concentrations specified in 10 CFR Part 20 Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases.

For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 micro-Curies/ml total activity.

B. The dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive material in liquid effluents released, from each reactor unit, to UNRESTRICTED AREAS shall be limited to:

During any calendar quarter to <= 1.5 mrems to the Total Body and to <= 5 mrems to any organ, and During any calendar year to

<= 3 mrems to the Total Body and to <= 10 mrems to any organ.

1.2 For Gaseous Waste Effluents:

A. The dose rate in UNRESTRICTED AREAS due to radioactive materials released in gaseous effluents from the site shall be limited to:

For Noble Gases: <= 500 mrems/yr to the total body and

<= 3000 mrems/yr to the skin, and For Iodine-131, Iodine-133, Tritium, and all radionuclides in particulate form with half-lives greater than 8 days:

<= 1500 mrems/yr to any organ.

  • B. The air dose due to noble gases released in gaseous effluents from each unit, to areas at and beyond the SITE BOUNDARYshall be limited to the following:

During any calendar quarter, to <= 5 mrads for gamma radiation, and

<= 10 mrads for beta radiation and, during any calendar year, to

<<= 10 mrads for gamma radiation and

<= 20 mrads for beta radiation.

  • C. The dose to a MEMBER OF THE PUBLIC from Iodine-1 31, Iodine-133, Tritium, and all radionuclides in particulate form, with half-lives > 8 Days in gaseous effluents released, from each unit to areas at and beyond the site boundary, shall be limited to the following:

During any calendar quarter to <= 7.5 mrem to any organ, and During any calendar year to

<= 15 mrem to any organ.

  • The calculated doses contained in an annual report shall not apply to any ODCM Control. The reported values are based on actual release conditions instead of historical conditions that the ODCM Control dose calculations are based on. The ODCM Control dose limits are therefore included in Item 1 of the report, for information only

0

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION(Continued)

2. Effluent Concentration Limits(ECL)

Water: Ten times the 10 CFR Part 20, Appendix B, Table 2, Column 2, except for entrained or dissolved noble gases as described in 1.1.A of this report.

Air:

Release concentrations are limited to dose rate limits described in 1.2.A. of this report.

3. Average Energy of fission and activation gases in gaseous effluents is not applicable.
4. Measurements and approximations of total radioactivity Where alpha, tritium, and listed nuclides are shown as zero Curies released, this should be interpreted as "no activity was detected on the samples using the ODCM Control analyses techniques to achieve required Lower Limitof Detection (LLD) sensitivity for radioactive effluents".

A summary of liquid effluent accounting methods is described in Table 3.1.

A summary of gaseous effluent accounting methods is described in Table 3.2.

4.1 Estimate of Errors Error To ic Release Point Mixin Sam lin Sam le Pre aration Sam le Analysis Release Volume LIQUID Av

. Max%

10 A

GASEOUS Max %

NA 10 15 Total Percent 30 10 35 The predictability of error for radioactive releases can only be applied to nuclides that are predominant in sample spectrums.

Nuclides that are near background relative to the predominant nuclides in a given sample could easily have errors greater than the above listed maximums.

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION(Continued)

4. Measurements and Approximations of Total Radioactivity (Cont.)

4.1 (Continued)

B. (Continued)

TABLE 3.1 RADIOACTIVELIQUIDEFFLUENT SAMPLING AND ANALYSIS Liquid Source Sampling Fre uenc T

e of Anal sis Method of Anal sis Each Batch Princi al Gamma Emitters

.h.a.

Monitor Tank Releases(1)

Monthly Com osite Quarterly Com osite Tritium Gross Al ha Sr-89, Sr-90, 8 Fe-55 L.S.

G.F.P.

C.S.

Continuous Releases Daily Grab Samples Principal Gamma Emitters 8 l-131 for 4/M Com osite Anal sis p.h.a.

Dissolved 8 Entrained Gases One Batch/ Month

.h.a.

Tritium Com osite Monthl L.S.

Al ha Com osite Monthl G.F.P.

Sr-89, Sr-90, f/ Fe-55 Com osite Quarterl C.S.

p.h.a.-

L.S.-

C.S.-

G.F.P.-

4/M-Boric Acid Evaporator Condensate is normally recovered to the Primary Water Storage Tank for recycling into the reactor coolant system and does not contribute to Liquid Waste Effluent Totals.

Gamma Spectrum Pulse Height Analysis using Germanium Detectors.

Allpeaks are identified and quantified.

Liquid Scintillation Counting Chemical Separation Gas Flow Proportional Counting Four per Month

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION(Continued)

4. Measurements and Approximations of Total Radioactivity (Continued) 4.1 (Continued)

B. (Continued)

TABLE3.2 RADIOACTIVEGASEOUS WASTE SAMPLINGANDANALYSIS Gaseous Source Waste Gas Decay Tank Releases Sampling Frequenc Each Batch T

e ofAnal sis Principal Gamma Emitters Method of Anal sis p.h.a.

Containment Purge Releases Each Purge Principal Gamma Emitters Tritium p.h.a L.S.

4/M Principal Gamma Emitters Tritium p.h.a.

L.S.

Plant Vent Monthly Com osite Particulate Gross AI ha G.F.P.

Quarterly Com osite Particulate Sr-89 8 Sr-90 C.S.

p.h.a.- Gamma Spectrum Pulse Height Analysis using Germanium Detectors.

Allpeaks are identified and quantified.

L.S.- Liquid Scintillation Counting C.S.- Chemical Separation G.F.P.- Gas Flow Proportional Counting 4/M - Four per Month

FLORIDAPOWER 8c LIGHTCOMPANY ST. LUCIEUNIT8 1 Ec 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION(Continued) 5.

Batch Releases A. Li uid Unit 1 Unit 2 Eng. Unit

1. Number of batch releases
2. Total time eriod for batch releases
3. Maximum time eriod for a batch release
4. Avera e time eriod for a batch release
5. Minimum time eriod for a batch release 41 21,338 8,50 520 225 40 20,859 850 521 225 minutes minutes minutes minutes
6. Average dilution stream flow during the eriod Allliquid releases are summarized in Tables II 841,868 841,868 B. Gaseous Unit 1 Unit 2 En

. Unit

1. Number of batch releases
2. Total time eriod for batch releases
3. Maximum time eriod fora batchrelease
4. Average time eriod for a batch release
5. Minimum time eriod fora batch release Allgaseous waste releases are summarized in Tables 6,892 1,552 627 101 75 5,974 minutes 647 minutes 80 minutes 15 minutes 6.

Unplanned Releases A. Li uid

1. Number of releases Unit 1 Unit 2 En

. Unit

2. Total activit of releases O.OOE+00 0.00E+00 Curies B. Gaseous
1. Number of releases Unit 1 Unit 2 En

. Unit

2. Total activit of releases 1.04E-02 O.OOE+00 Curies C. see attachments (ifapplicable) for:
1. A description of the event and equipment involved
2. Cause(s) for the unplanned release.
3. Actions taken to prevent a recurrence.
4. Consequences of the unplanned release.

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION(Continued) 7.

Assessment of radiation dose from radioactive effluents to MEMBES OF THE PUBLIC due to their activities inside the SITE BOUNDARYassumes the VISITOR onsite for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> per day for 312 days per year at a distance of 1.6 kilometers in the South East Sector.

The VISITOR received exposure from each of the two reactors on the Site.

VISITOR DOSE RESULTS FOR CALENDARYEAR 1996 were:

Gamma AirDose 4.49E-04 Beta AirDose 6.18E-04 GASEOUS PARTICULATE 8 IODINE EXPOSURE Bone Liver Thyroid Kidney Lung Gl-LLI Total Body DOSE mRem 9.69E-07 3.75E-04 4.27E-04 1.64E-04 3.82E-04 3.75E-04 5.20E-04 8.

Offsite Dose Calculation Manual(ODCM) Revision(s):

Revision 18 was implemented on September 23, 1996 The purpose of this change was to augment Surveillance 4.11.2.4.2 with an Administrative FUNCTIONALTEST. This insures that a Waste Gas Compressor is capable of charging a Gas Decay Tank from less than 30 psi up to at least 150 psi, and following hold-up decay time, that the same Gas Decay Tank can be discharged with an OPERABLE Waste Gas Holdup System Noble Gas ActivityMonitor.

The FUNCTIONALTEST also dictates that repairs shall be made until a Post Maintenance 4.11.2.4.2 FUNCTIONALTEST SURVEILLANCEis completed satisfactorily.

9.

Solid Waste and Irradiated Fuel Shipments:

No irradiated fuel shipments were made for the site Common Solid waste from St. Lucie Units 1 and 2 were shipped jointly.

A tabulated summation of these shipments is provided in this report as Table 3.9. Solid Waste Shipments as Sewage Sludge were made off-site. These Shipments are summarized in Table 3.10.

10. Process Control Program (PCP) Revisions:

During the reporting period there were no significant changes to the Process Control Program.

FLORIDAPOWER 8'c LIGHTCOMPANY ST. LUCIEUNIT¹ 1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.3-1 LIQUIDEFFLUENTS - SUMMATIONOF ALLRELEASES UNIT QTR¹1 QTR¹2 A. Fission and Activation Products

1. Total Release - (Not including Tritium, Gases, and Alpha)

Ci 7.42E-02 1.88E-01

2. Average Diluted Concentration During Period uCi/ml 1.47E-10 5.66E-10 B. Tritium
1. Total Release Ci 5.63E+01 1.55E+02
2. Average Diluted Concentration During Period uCi/ml 1.12E-07 4.67E-07 C. Dissolved and Entrained Gases
1. Total Release Ci 1.19E-01 1.48E-01
2. Average Diluted Concentration During Period uCi/ml 2.37E-10 4.45E-10 D. Gross Alpha Radioactivity
1. Total Release Ci 0.00E+00 0.00E+00 E. Volume ofWaste Released (Prior to Dilution)

Liters 3.11E+07 1.93E+07 F. Volume ofDilutionWater Used During Period Liters 5.04E+11 3.32E+11

FLORIDAPOWER 8c LIGHTCOMPANY ST. LUCIEUNIT¹ 1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.3-1 LIQUIDEFFLUENTS - SUMMATIONOF ALLRELEASES UNIT QTR¹3 QTR¹4 A. Fission and Activation Products

1. Total Release - (Not including Tritium, Gases, and Alpha)

Ci 2.28E-01 1.36E-02

2. Average Diluted Concentration During Period uCi/ml 5.34E-10 2.65E-11 B. Tritium
1. Total Release Ci 3.59E+01 1.55E+01
2. Average Diluted Concentration During Period uCi/ml 8.43E-08 3.03E-08 C. Dissolved and Entrained Gases
1. Total Release Ci 5.31E-03 8.24E-05
2. Average Diluted Concentration During Period uCi/ml 1.25E-11 1.61E-13 D. Gross Alpha Radioactivity
1. Total Release Ci 2.19E-05 0.00E+00 E. Volume ofWaste Released (Prior to Dilution)

Liters 3.16E+07 2.97E+07 F. Volume ofDilutionWater Used During Period Liters 4.26E+11 5.12E+11

FLORIDAPOWER 2 LIGHTCOMPANY ST. LUCIEUNIT¹ 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.3-2 LIQUIDEFFLUENTS - SUMMATIONOF ALLRELEASES UNIT QTR¹1 QTR¹2 A. "Fission and Activation Products

1. Total Release - (Not including Tritium, Gases, and Alpha)

Ci 4.09E-02 1.57E-01

2. Average Diluted Concentration During Period uCi/ml 8.12E-11 4.73E-10 B. Tritium
1. Total Release Ci 5.60E+01 1.55E+02
2. Average Diluted Concentration During Period uCi/ml 1.11E-07 4.67E-07 C. Dissolved and Entrained Gases
1. Total Release Ci 1.19E-01 1.48E-01
2. Average Diluted Concentration During Period uCi/ml 2.37E-10 4.45E-10 D. Gross Alpha Radioactivity
1. Total Release Ci 0.00E+00 0.00E+00 E. Volume ofWaste Released (Prior to Dilution)

Liters 1.03E+06 1.88E+06 F. Volume ofDilutionWater Used During Period Liters 5.04E+11 3.32E+11

FLORIDAPOWER 8'c LIGHTCOMPANY ST. LUCIEUNIT8 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.3-2 LIQUIDEFFLUENTS - SUMMATIONOF ALLRELEASES UNIT QTRP3 QT1Vf4 A. Fission and Activation Products

1. Total Release - (Not including Tritium, Gases, and Alpha)

Ci 2.19E-01 1.34E-02

2. Average Diluted Concentration During Period uCi/ml 5.14E-10 2.61E-11 B. Tritium
1. Total Release Ci 3.54E+01 1.50E+01
2. Average Diluted Concentration During Period uCi/ml 8.31E-08 2.93E-08 C. Dissolved and Entrained Gases
1. Total Release Ci 5.31E-03 8.24E-05
2. Average Diluted Concentration During Period uCi/ml 1.25E-11 1.61E-13 D. Gross Alpha Radioactivity
1. Total Release Ci 2.25E-05 0.00E+00 E. Volume ofWaste Released (Prior to Dilution)

Liters 1.02E+06 4.95E+05 F. Volume ofDilutionWater Used During Period Liters 4.26E+11 5.12E+11 10

FLORIDAPOWER 8c LIGHTCOMPANY ST. LUCIEUNIT¹ 1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.4-1 LIQUIDEFFLUENTS NUCLIDES RELEASED Continuous Mode UNIT QTR¹1 QTR¹2 Batch Mode QT1Vt1 QT1Vt2

¹24 Cr-51 Mn-54 Fe-55 Mn-56 Co-57 Co-58 Fe-59 Co-60 Zn-65 Ni-65 Br-82 Rb-88 Sr-89 Sr-90 Y-90 Sr-91 Sr-92 Y-92 Zr-95 Nb-95 Zr-97 Nb-97 Tc-99m Mo-99 Ru-103 Ag-110 Sn-113 Sb-122 Sb-124 Sb-125 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 3.23E-02 1.57E-03 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 8.76E-05 0.00E 00 0.00E 00 1.13E-04 1.32E-04 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 8.39E-03 0.00E 00 3.75E-04 0.00E 00 3.75E-04 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 4.18E-04 0.00E 00 0.00E 00 2.67E-04 0.00E 00 1.33E-05 1.14E-03 5.02E-04 8.35E-03 0.00E+00 2.20E-05 6.20E-03

, 5.55E-05 1.04E-02 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.16E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 4.50E-04 1.48E-03 0.00E 00 1.63E-05 0.00E 00 0.00E 00 0.00E 00 2.89E-03 4.17E-05 0.00E 00 1.01E-03 7.68E-03 2.58E-04 9.70E-03 8.78E-04 1.71E-02 0.00E 00 2.71E-05 3.34E-02 1.38E-03 1.34E-02 0.00E 00 0.00E 00 0.00E 00 0.00E 00 3.77E-06 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.40E-03 2.57E-03 0.00E 00 2.16E-05 0.'00E 00 0.00E 00 2.49E-05 2.30E-03 1.81E-04 8.39E-04 1.11E-02, 3.94E-02 11

FLORIDAPOWER &LIGHTCOMPANY ST. LUCIEUNIT8 1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.4-1 LIQUIDEFFLUENTS NUCLIDES RELEASED UNIT Continuous Mode QTIUt1 QTRP2 Batch Mode QTR81 QTIUI2 Te-129 Te-129m I-131 Te-132 I-132 I-133 I-134 Cs-134 I-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Ce-141 Ce-144 Pr-144 W-187 Np-239 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00'0 1.25E-04 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.72E-04 0.00E 00 0.00E 00 2.09E-04 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.17E-03 0.00E 00 0.00E 00 7.99E-03 0.00E 00 5.63E-03 0.00E 00 0.00E 00 4.59E-03, 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 5.46E-06 0.00E 00 0.00E 00 0.00E 00 0.00E 00

'.07E-04 0.00E 00 0.00E 00 3.59E-04 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 3.03E-03 3.01E-04 3.16E-05 9.95E-05 6.53E-05 1.91E-05 0.00E 00 9.64E-03 0.00E 00 0.00E 00 8.85E-03, 1.34E-04 0.00E 00 5.46E-04 0.00E 00 0.00E 00 4.31E-04 0.00E 00 0.00E 00 TOTALFOR PERIOD Ci 3.33E-02 3.07E-02 4.09E-02 1.57E-01 Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 6.00E-05 0.00E 00 0.00E 00 0.00E 00 1.55E-03 6.97E-04 1.17E-01 0.00E 00 1.87E-05 3.84E-05 0.00E 00 7.41E-03 0.00E 00 0.00E 00 1.15E-03 1.71E-03 1.37E-01 0.00E 00 4.09E-04 12

FLORIDAPOWER &LIGHTCOMPANY ST. LUCIEUNIT¹ 1 ANNUALREPORT JANUARY 1, 1996 THROUGHDECEMBER 31, 1996 TABLE3.4-1 LIQUIDEFFLUENTS NUCLIDES RELEASED Continuous Mode UNIT QTR¹3 QTR¹4 Batch Mode QTR¹3 QTR¹4

¹24 Cr-51 Mn-54 Fe-55 Mn-56 Co-57 Co-58 Fe-59 Co-60 Zn-65 Ni-65 Br-82 Rb-88 Sr-89 Sr-90 Y-90 Sr-91 Sr-92 Y-92 Zr-95 Nb-95 Zr-97 Nb-97 Tc-99m Mo-99 Ru-103 Ag-110 Sn-113 Sb-122 Sb-124 Sb-125 Ci Ci.

Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 2.26E-03 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 6.11E-04 8.86E-05 8.86E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.04E-04 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.86E-05 5.53E-02

,3.09E-03 2.37E-02 0.00E 00 1.37E-04 5.34E-02 3.02E-03 3.19E-02 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.13E-05 4.39E-06 4.39E-06 0.00E 00 0.00E 00 0.00E 00 1.42E-02 2.34E-02 0.00E 00 1.60E-04 0.00E 00 0.00E 00 1.23E-04 1.21E-04 1.46E-03 0.00E 00 1.88E-03 4.04E-03 1.51E-05 0.00E 00 1.48E-04 4.67E-03 0.00E 00 0.00E 00 9.06E-04 0.00E 00 1.05E-03 0.00E 00 0.00E 00 0.00E 00 0.00E 00 9.89E-07 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 3.69E-05 1.71E-04 0.00E 00 1.59E-04 0.00E 00 3.47E-04 0.00E 00 1.40E-04 0.00E 00 1.58E-04 1.99E-04 2.15E-03 13

1 q

k

FLORIDAPOWER &LIGHTCOMPANY ST. LUCIEUNIT¹ 1

ANNUALREPORT JANUARY 1, 1996 THROUGHDECEMBER 31, 1996 TABLE3.4-1 LIQUIDEFFLUENTS (continued)

NUCLIDES RELEASED Continuous Mode UNIT QTR¹3 QTR¹4 Batch Mode QTR¹3 QTR¹4 Te-129 Te-129m I-131 Te-132 I-132 I-133 I-134 Cs-134 I-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Ce-141 Ce-144 Pr-144 W-187 Np-239 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.85E-03 0.00E 00 0.00E 00 2.82E-03 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.04E-03 0.00E 00 0.00E 00 1.29E-03 0.00E 00 0.00E 00 4.15E-05 0.00E 00 5.98E-04 0.00E 00 0.00E 00 0.00E 00 1.02E-03 0.00E 00 1.73E-06 9.56E-06 4.05E-05 0.00E 00 0.00E 00 1.00E-03 0.00E 00 6.42E-05 1.07E-03 0.00E 00 0.00E 00 0.00E 00 1.13E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 TOTALFOR PERIOD Ci 8.72E-03 2.04E-04 2.19E-01 1.34E-02 Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 5.31E-03 0.00E 00 0.00E 00 0.00E 00 6.23E-06 0.00E 00 0.00E 00 4.47E-05 0.00E 00 0.00E 00 2.16E-05 0.00E 00 9.86E-06 14

0

't

FLORIDAPOWER 2 LIGHTCOMPANY ST. LUCIEUNIT8 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.4-2 LIQUIDEFFLUENTS NUCLIDES RELEASED Continuous Mode UNIT QTRP1 QTIUt2 Batch Mode QTIV1 QTRP2 Te-129 Te-129m I-131 Te-132 I-132 I-133 I-134 Cs-134 I-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Ce-141 Ce-144 Pr-144 W-187 Np-239 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 5.46E-06 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 3.07E-04 O.OOE 00 0.00E 00 3.59E-04 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 0.00E 00 3.03E-03 3.01E-04 3.16E-05 9.95E-05 6.53E-05 1.91E-05 O.OOE 00 9.64E-03 O.OOE 00 0.00E 00 8.85E-03 1.34E-04 O.OOE 00 5.46E-04 0.00E 00 O.OOE 00 4.31E-04 O.OOE 00 O.OOE 00 TOTALFOR PERIOD Ci O.OOE+00 O.OOE+00 4.09E-02 1.57E-01 Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 6.00E-05 0.00E 00 O.OOE 00 0.00E 00 1.55E-03 6.97E-04 1.17E-01 0.00E 00 1.87E-05 3.84E-05 0.00E 00 7.41E-03 O.OOE 00 0.00E 00 1.15E-03 1.71E-03 1.37E-01 0.00E 00 4.09E-04 16

FLORIDAPOWER 2 LIGHTCOMPANY ST. LUCIEUNIT8 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.4-2 LIQUIDEFFLUENTS NUCLIDES RELEASED

'ontinuous Mode UNIT QTIUI'3 QTEQ4 Batch Mode QTRP3 QTRP4 Na-24 Cr-51 Mn-54 Fe-55 Mn-56 Co-57 Co-58 Fe-59 Co-60 Zn-65 Ni-65 Br-82 Rb-88 Sr-89 Sr-90 Y-90 Sr-91 Sr-92 Y-92 Zr-95 Nb-95 Zr-97 Nb-97 Tc-99m Mo-99 RU-103 Ag-110 Sn-113 Sb-122 Sb-124 Sb-125 Ci Ci Ci Ci Ci Ci

'Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.86E-05 5.53E-02 3.09E-03 2.37E-02 0.00E 00 1.37E-04 5.34E-02 3.02E-03 3.19E-02 0.00E 00 0.00E 00 0.00E 00 0.00E 00

'1.13E-05 4.39E-06 4.39E-06 0.00E 00 0.00E 00 0.00E 00 1.42E-02 2.34E-02 0.00E 00 1;60E-04 0.00E 00 0.00E 00 1.23E-04 1.21E-04 1.46E-03 0.00E 00 1.88E-03 4.04E-03 1.51E-05 0.00E 00 1.48E-04 4.67E-03 0.00E 00 0.00E 00 9.06E-04 0.00E 00 1.05E-03 0.00E 00 0.00E 00 0.00E 00 0.00E 00 9.89E-07 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 3.69E-05 1.71E-04 0.00E 00 1.59E-04 0.00E 00 3.47E-04 0.00E 00 1.40E-04 0.00E 00 1.58E-04 1.99E-04 2.15E-03 17

FLOMDAPOWER &LIGHTCOMPANY ST. LUCIEUNIT¹ 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.4-2 LIQUIDEFFLUENTS NUCLIDES RELEASED Continuous Mode UNIT QTR¹3 QTR¹4 Batch Mode QTR¹3 QTR¹4 Te-129 Te-129m I-131 Te-132 I-132 I-133 I-134 Cs-134 I-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Ce-141 Ce-144 Pr-144 W-187 Np-239 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 0.00E 00 O.OOE 00 1.04E-03 0.00E 00 O.OOE 00 1.29E-03 O.OOE 00 O.OOE 00 4.15E-05 0.00E 00 5.98E-04 0.00E 00 O.OOE 00 O.OOE 00 1.02E-03 0.00E 00 1.73E-06 9.56E-06 4.05E-05 O.OOE 00 O.OOE 00 1.00E-03 0.00E 00 6.42E-05 1.07E-03 O.OOE 00 O.OOE 00 0.00E 00 1.13E-05 0.00E 00 O.OOE 00 0.00E 00 O.OOE 00 TOTALFOR PERIOD Ci O.OOE+00 O.OOE+00 2.19E-01 1.34E-02 Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 0.00E 00 5.31E-03 0.00E 00 0.00E 00 O.OOE 00 6.23E-06 0.00E 00 0.00E 00 4.47E-05 0.00E 00 0.00E 00 2.16E-05 0.00E 00 9.86E-06 18

T H

0'

FLORIDAPOWER 2 LIGHTCOMPANY ST. LUCIEUNIT8 1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE 3.5-1 LIQUID EFFLUENTS - DOSE SUMMATION AGE GROUP:

ADULT LOCATION:

ANYADULT FISH AND SHELLFISH ORGAN DOSE mrem Bone 5.53E-02 Liver 2.40E-01 Thyroid Kidney Lung Gl-LLI Total Body 2.14E-03 1.58E-03 2.76E-01 3.46E-01 6.67E-02 19

FLORIDAPOWER &LIGHTCOMPANY ST. LUCIEUNIT¹ 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.5-2 LIQUID EFFLUENTS - DOSE SUMMATION AGE GROUP:

ADULT LOCATION:

ANYADULT FISH AND SHELLFISH ORGAN DOSE mrem Bone 3.35E-02 Liver 1.46E-01 Thyroid Kidney Lung Gl-LLI Total Body 4.92E-04 1.18E-03 1.68E-01 3.10E-01 4.14E-02 20

FLORIDAPOWER 2 LIGHTCOMPANY ST. LUCIEUNIT¹ 1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.6-1 GASEOUS EFFLUENTS - SUMMATIONOF ALLRELEASES A. Fission and Activation Gases UNIT QTR¹1 QTR¹2

1. Total Release Ci 8.95E+00 9.98E+00
2. Average Release Rate For Period uCi/sec 1.14E+00 1.27E+00 B. Iodines
1. Total Iodine-131 Ci 9.91E-06 1.19E-04
2. Average Release Rate For Period uCi/sec 1.26E-06 1.51E-05 C. Particulates
1. Particulates (HalfLife> 8 days)

Ci 2.57E-05 9.95E-05

2. Average Release Rate For Period uCi/sec 3.27E-06 1.27E-05
3. Gross Alpha Radioactivity Ci 0.00E 00 0.00E 00 D. Tritium
1. Total Release Ci 6.16E+00 2.60E+01
2. Average Release Rate For Period uCi/sec 7.83E-01 3.31E+00 21

FLORIDAPOWER 2, LIGHTCOMPANY ST. LUCIEUNIT¹,1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.6-1 GASEOUS EFFLUENTS - SUMMATIONOF ALLRELEASES(Continued)

A. Fission and Activation Gases UNIT QTR¹3 QTR¹4

1. Total Release Ci 5.47E+00 1.31E+01 2: Average Release Rate For Period uCi/sec 6.95E-01 1.66E+00 B. Iodines
1. Total Iodine-131 Ci 0.00E 00 0.00E 00
2. Average Release Rate For Period uCi/sec 0.00E+00 0.00E+00 C. Particulates
1. Particulates (HalfLife> 8 days)

Ci 1.98E-05 1.59E-05

2. Average Release Rate For Period uCi/sec 2.52E-06 2.02E-06
3. Gross Alpha Radioactivity Ci 8.90E-08 0.00E 00 D. Tritium
1. Total Release Ci 3.88E+00 3.62E+01
2. Average Release Rate For Period uCi/sec 4.93E-01 4.61E+00 22

n'

FLORIDAPOWER k LIGHTCOMPANY ST. LUCIEUNIT0 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.6-2 GASEOUS EFFLUENTS - SUMMATIONOF ALLRELEASES A. Fission and Activation Gases UNIT QTRP1 QTRP2

1. Total Release Ci 2.09E-01 8.85E+00
2. Average Release Rate For Period uCi/sec 2.65E-02 1.13E+00 B. Iodines
1. Total Iodine-131 Ci 0.00E 00 5.99E-05
2. Average Release Rate For Period uCi/sec 0.00E+00 7.62E-06 C. Particulates
1. Particulates (HalfLife> 8 days)

Ci 1.21E-05 5.71E-05

2. Average Release Rate For Period uCi/sec 1.53E-06 7.26E-06
3. Gross Alpha Radioactivity Ci,1.11E-07 0.00E 00 D. Tritium
1. Total Release Ci 1.53E+00 1.14E+01
2. Average Release Rate For Period uCi/sec 1.95E-01 1.45E+00 23

FLORIDAPOWER &, LIGHTCOMPANY ST. LUCIEUNITP 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.6-2 GASEOUS EFFLUENTS - SUMMATIONOF ALLRELEASES(Con UNIT QTIQ3 QTIUt4 A. Fission and Activation Gases

1. Total Release Ci 2.60E+00 1.79E+00
2. Average Release Rate For Period uCi/sec 3.30E-01 2.28E-01 B. Iodines
1. Total Iodine-131 Ci 3.43E-05 4.21E-05
2. Average Release Rate For Period uCi/sec 4.36E-06 5.36E-06 C. Particulates
1. Particulates (HalfLife> 8 days)

Ci 1.72E-05 3.09E-05

2. Average Release Rate For Period uCi/sec 2.19E-06 3.94E-06
3. Gross Alpha Radioactivity Ci 4.89E-08 4.51E-08 D. Tritium
1. Total Release Ci 1.17E+00 3.75E+01
2. Average Release Rate For Period uCi/sec 1.49E-01 4.77E+00 24

FLORIDAPOWER 8 LIGHTCOMPANY ST. LUCIE UNIT¹1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE 3.7-1 GASEOUS EFFLUENTS - GROUND LEVELRELEASES(Continued)

Nuclides Released Unit Continuous Mode QTR¹1 QTR¹2 Batch Mode QTR¹1 QTR¹2

1. Fission Gases Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-127 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Total for Period
2. Iodines I-131 I-132 l-133 I-134 I-135 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 6.04E+00 0.00E 00 2.45E+00 0.00E 00 0.00E 00 8.50E+00 9.91E-06 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 9.91E-06 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 6.95E+00 0.00E 00 2.06E+00 0.00E 00 0.00E 00 9.01E+00 1.19E-04 3.35E-03 1.02E-04 0.00E 00 O.OOE 00 3.57E-03 2.41E-02 9.79E-03 0.00E 00 0.00E 00 1.00E-02 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.16E-02 2.60E-01 0.00E 00 1.36E-01 0.00E 00 0.00E 00 4.51E-01 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.11E-02 9.58E-01 0.00E 00 6.03E-03 0.00E 00 0.00E 00 9.75E-01
3. Particulates

(>

Cr-51 Mn-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Zr-95 Nb-95 8 Days)

Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 8.80E-06 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 6.25E-05 0.00E 00 0.00E 00 0.00E 00 25

FLORIDAPOWER 8 LIGHTCOMPANY ST. LUCIE UNIT¹1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE 3.7-1 GASEOUS EFFLUENTS - GROUND LEVELRELEASES(Continued)

Continuous Mode Nuclides Unit QTR¹1 QTR¹2 Released

3. Particulates ( > 8 Days) (continued)

Sr-89 Sr-90 Y-90 Ru-103 Ag-110 Sn-113 Sb-124 Sb-125 Te-129m Cs-134 Cs-136 Cs-137

, Ba-140 Ce-141 Ce-144 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 1.21E-05 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 4.86E-06 O.OOE+00 O.OOE+00 O.OOE+00 2.57E-05 1.96E-06 1.13E-06 1.13E-06 0.00E+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 3.19E-05 0.00E+00 0.00E+00 8.31E-07 0.00E+00 O.OOE+00 0.00E+00 9.95E-05

4. Particulates (< 8 Days)

Mn-56 Ni-65 Br-82 Rb-88 Rb-89 Sr-91 Sr-92 Y-92 Zr-97 Nb-97 Tc-99m Mo-99 Sb-122 Te-129 Te-132 Cs-138 La-140 Pr-144 W-187 Np-239 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E+00 26

FLORIDAPOWER 8 LIGHTCOMPANY ST. LUCIE UNIT¹1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.7-1 GASEOUS EFFLUENTS - GROUND LEVELRELEASES(Continued)

Nuclides Released Unit Continuous Mode QTR¹3 QTR¹4 Batch Mode QTR¹3 QTR¹4

1. Fission Gases Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-127 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 2.72E+00 0.00E 00 1.34E+00 0.00E 00 0.00E 00 4.06E+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 7.82E+00 0.00E 00 3.81E+00 0.00E 00 1.42E+00 0.00E 00 0.00E 00 1.31E+01 1.81E-01 2.24E-02 0.00E 00 5.18E-03 3.53E-02 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.90E-02 6.04E-01 0.00E 00 5.38E-01 0.00E 00 0.00E 00 1.41E+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E+00
2. Iodines I-131 I-132 1-133 I-134 I-135 Total for Period Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 2.02E-05 0.00E 00 O.OOE 00 2.02E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E+00
3. Particulates

( > 8 Days)

Cr-51 Mn-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Zr-95 Nb-95 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 8.85E-07 0.00E 00 0.00E 00 8.21E-06 0.00E 00 0.00E 00 0.00E 00 1.04E-05 0.00E 00 0.00E 00 1.34E-06 0.00E 00 0.00E 00 9.43E-07 0.00E 00 0.00E 00 0.00E 00 27

FLORIDA POWER & LIGHTCOMPANY ST. LUCIE UNIT¹1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE 3.7-1 GASEOUS EFFLUENTS - GROUND LEVELRELEASES(Continued)

Nuclides Released

3. Particulates (> 8 Unit Days) (continued)

Continuous Mode QTR¹3 QTR¹4 Sr-89 Sr-90 Y-90 Ru-103 Ag-110 Sn-113 Sb-124 Sb-125 Te-129m Cs-134 Cs-136 Cs-137 Ba-140 Ce-141 Ce-144 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 2.65E-06 1.43E-06 1.43E-06 0.00E 00 0.00E 00 0.00E 00 0.00E 00 3.41E-07 0.00E 00 0.00E 00 O.OOE 00 4.90E-06 0.00E 00 0.00E 00 0.00E 00 1.98E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 3.20E-06 O.OOE OO 0.00E 00 0.00E 00 1.59E-05

4. Particulates

( < 8 Days)

Mn-56 Ni-65 Br-82 Rb-88 Rb-89 Sr-91 Sr-92 Y-92 Zr-97 Nb-97 Tc-99m Mo-99 Sb-122 Te-129 Te-132 Cs-138 La-14O Pr-144 W-187 Np-239 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 4.79E-04 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 4.79E-04 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E+00 28

FLORIDAPOWER &, LIGHTCOMPANY ST. LUCIEUNIT¹ 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.7-2 GASEOUS EFFLUENTS - GROUND LEVELRELEASES Nuclides Released Unit Continuous Mode QTR¹1 QTR¹2 Batch Mode QTR¹1 QTR¹2

1. Fission Gases Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-127 Xe-131m Xe-133m Xe-1 33 Xe-135m Xe-1 35 Xe-137 Xe-138 Total for Period
2. lodines I-131 l-132 I-133 1-134 1-1 35 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 6.13E+00 0.00E 00 2.11E+00 0.00E 00 0.00E 00 8.24E+00 5.99E-05 0.00E 00 3.25E-05 0.00E 00 0.00E 00 9.24E-05 1.88E-01 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.82E-02 0.00E 00 2.02E-03 O.OOE 00 O.OOE 00 2.09E-01 1.90E-01 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.74E-03 4.14E-01 0.00E 00 2.78E-03 0.00E 00 0.00E 00 6.09E-01
3. Particulates () 8 Days)

Cr-51 Mn-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Zr-95 Nb-95 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.39E-06 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 5.01E-05 0.00E 00 0.00E 00 0.00E 00 29

FLORIDAPOWER &, LIGHTCOMPANY ST. LUCIEUNIT0 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.7-2 GASEOUS EFFLUENTS - GROUND LEVELRELEASES(Continued)

Continuous Mode Nuclides Unit QTR¹1 QTR¹2 Released

3. Particulates (> 8 Days) (continued)

Sr-89 Sr-90 Y-90 Ru-103 Ag-110 Sn-113 Sb-124 Sb-125 Te-129m Cs-134 Cs-136 Cs-137 Ba-140 Ce-141 Ce-144 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 5.34E-06 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 4.33E-06 0.00E 00 0.00E 00 0.00E 00 1.21E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 7.02E-06 0.00E 00 0.00E 00 0.00E 00 5.71E-05

4. Particulates

( < 8 Days)

Tot Mn-56 Ni-65 Br-82 Rb-88 Rb-89 Sr-91 Sr-92 Y-92 Zr-97 Nb-97 Tc-99m Mo-99 Sb-122 Te-129 Te-132 Cs-138 La-140 Pr-144 W-187 Np-239 al for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 3.09E-04 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 3.09E-04 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE+00 30

FLORIDAPOWER 2 LIGHTCOMPANY ST. LUCIEUNIT8 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE 3.7-2 GASEOUS EFFLUENTS - GROUND LEVELRELEASES(Continued)

Nuclides Released Unit Continuous Mode QTR¹3 QTR¹4 Batch Mode QTR¹3 QTR¹4

1. Fission Gases Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-127 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Total for Period
2. Iodines I-131 1-132 I-133 I-134 I-135 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 000EOO" 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.25E+00 0.00E 00 0.00E 00 2.25E+00 3.43E-05 0.00E 00 1.63E-04 0.00E 00 0.00E 00 1.97E-04 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 5.37E-01 0.00E 00 0.00E 00 5.37E-01 4.21E-05 0.00E 00 4.39E-04 0.00E 00 0.00E 00 4.81E-04 3.17E-01 0.00E 00 1.98E-02 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 7.86E-03 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 3.45E-01 1.16E+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.28E-04 9.12E-02 1.46E-03 0.00E 00 0.00E 00 6.42E-04 1.26E+00
3. Particulates

(> 8 Days)

Cr-51'n-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Zr-95 Nb-95 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci O.OOE 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 6.90E-06 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 3.99E-06 0.00E 00 0.00E 00 2.87E-06 0.00E 00 0.00E 00 0.00E 00 31

FLORIDAPOWER &LIGHTCOMPANY ST. LUCIEUNIT¹ 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE 3.7-2 GASEOUS EFFLUENTS - GROUND LEVELRELEASES(Continued)

Continuous Mode Nuclides Unit QTR¹3 QTR¹4 Released

3. Particulates ( > 8 Days) (continued)

Sr-89 Sr-90 Y-90 Ru-103 Ag-110 Sn-113 Sb-124 Sb-125 Te-129m Cs-134 Cs-136 Cs-137 Ba-140 Ce-141 Ce-144 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 6.37E-06 7.74E-07 7.74E-07 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 O.OOE 00 2.39E-06 0.00E 00 0.00E 00 0.00E 00 1.72E-05 0.00E 00 3.14E-06 3.14E-06 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.69E-05 0.00E 00 9.15E-07 0.00E 00 3.09E-05

4. Particulates (< 8 Days)

Mn-56 Ni-65 Br-82 Rb-88 Rb-89 Sr-91 Sr-92 Y-92 Zr-97 Nb-97 Tc-99m Mo-99 Sb-122 Te-129 Te-132 Cs-138 La-140 Pr-144 W-187 Np-239 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 1.71E-06 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.71E-06 32

t

FLORIDAPOWER &,LIGHTCOMPANY ST. LUCIEUNIT8 1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.8-1 GASEOUS EFFLUENTS - DOSE SUMMATION AGE GROUP:

INFANT Pathwa Ground Plane a Cow - Milk b

Inhalation a

Total Bone mrem 3.40E-05 7.96E-07 3.48E-05 Liver mrem 4.02E-04 4.84E-04 8.86E-04 Thyroid Kidney mrem mrem 2.67E-03 1.68E-04 5.25E-04 2.1 2E-04 3.20E-03 3.80E-04 Pathwa Ground Plane a Lung mrem GI-LLI mrem T. Body mrem 1.60E-04 Cow - Milk b

3.79E-04 3.78E-04 3.85E-04 Inhalation a

4.93E-04 4.84E-04 4.84E-04 Total 8.72E-04 8.62E-04 1.03E-03 (a) Sector:

SE (b) Sector:

SE Range:

Range:

1.50 miles 4.25 miles(default)

Noble Gases Gamma AirDose Beta AirDose mrad 4.92E-04 9.52E-04 Sector:

SE Range:

1.5 miles 33

II

FLORIDAPOWER 2, LIGHTCOMPANY ST. LUCIEUNIT0 2 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.8-2 GASEOUS EFFLUENTS - DOSE SUMMATION AGE GROUP:

INFANT Pathwa Bone Liver mrem mrem Thyroid Kidney mrem mrem Ground Plane a Cow - Milk b

5.62E-05 3.17E-04 Inhalation a

1.35E-06 3.46E-04 2.82E-03 1.22E-04 4.21E-04 1.51E-04 Total 5.75E-05 6.63E-04 3.24E-03 2.73E-04 Pathwa Ground Plane a Lung mrem GI-LLI mrem T. Body mrem 1.41E-04 Total 6.26E-04 Cow - Milk b

2.74E-04 Inhalation a

3.52E-04 2.70E-04 3.45E-04 6.16E-04 2.79E-04 3.46E-04 7.66E-04 (a) Sector:

SE (b) Sector:

SE Range:

Range:

1.50 miles 4.25 miles(default)

Noble Gases Gamma AirDose Beta AirDose mrad 5.36E-04 4.65E-04 Sector:

SE Range:

1.5 miles 34

k 0

FLORIDA POWER AND LIGHTCOMPANY ST. LUCIE PLANT ANNUALREPORT JANUARY1, 1996 THROUGH DECEMBER 31, 1996 UNITS 1 AND 2, TABLE3.9 A.

Solid Waste Shipped Off-Site for Burial or Disposal 1.

Type of Waste a.

Spent Resin, Process Filters (Note 6) 2.0 E+ 1 Unit 12 Mo. Period Error %

M 209 E+1 Ci 9.09 E+1 b.

Dry Compressible Waste (Note 5) c.

Irradiated Components d.

Other (Note 7)

M'.14 E+ 1 Ci 4.07 E+ 1 M

0.00 E+ 0 Ci 000 E+0 M

0.00 E+ 0 Ci 000 E+0 2.0 E+1 N/A

  • 2.

Estimate of Major Nuclide Composition (By Waste Type)

~

~

Category a.

Nuclides Cs 137 Co 58 Cs 134 Co 60 Ni 63 Fe 55 Sb 125 Mn 54 2.62 E+ 1 1.84 E+ 1 1.56 E+ 1 1.55 E+ 1 9.07 E+ 1 8.96 E+ 0 3.20 E+ 0 3 02 E+ 0 b.

Fe 66 Co 60 Co 68 Ni 63 Cs 137 Cs 134 Mn 54 Zr 95 Nb 95 7.34 E+ 1 7.24 E + 0 5.73 E+ 0 4.26 E+ 0 4.02 E+ 0 1.46 E+ 0 1.13 E+ 0 1.02 E+ 0 6.00 E-1 C.

NIA*

N/A*

d.

N/A" N/A*

35

3.

Solid Waste Disposition

~

~

Number of Shipments Mode of Transportation Destination 17 Sole Use Truck Sole Use Truck Sole Use Truck Barnwell, S.C.

S.E.G., Oak Ridge, TN M.S.C., Oak Ridge, TN B.

Irradiated Fuel Shipments Number of Shipments Mode of Transportation Destination N/A*

N/A

'N/A

= Not Applicable 36

FLORIDA POWER AND LIGHT COMPANY ST. LUCIE PLANT ANNUALREPORT JANUARY 1, 'l996 THROUGH DECEMBER 31, 1996 UNITS 1 AND 2, TABLE3.9 (CONTINUED)

'aste Class Class A Class A Class A Class B Class B Total Volume Cubic Ft.

1409.2 404.2 404.2 132.4 202.1 Total Curiae (Note 1) 1.841 38.738 15.767 54.991 20.156 Principal Badionuclides (Notes 1 tk 2)

N/A N)N SrN Coul Ni", Sr", Csur Ni",Sr", Csnr Ni,Sr, Csuo Type of Waste (Note 3)

PWR Compactible Trash (Note 5)

PWR Compactible Trash (Note 5)

PWB ion Exchange Resin PWR ion Exchange Resin PWR ion Exchange Resin Category Reg.Guide 1.21 1.b 1.a 1.a Type of Conta<ner (Note 4)

Non.Specification Strong Tight Package NRC Certified LSA >Type A NRC Certified LSA >Type A NRC Certified Type B NBC Certified LSA >Type A Solidification Agent None None None None None

FLORIDA POWER AND LIGHTCOMPANY ST. LUCIE PLANT ANNUALREPORT JANUARY1, 1996 THROUGH DECEMBER 31, 1996 UNITS 1 AND 2, TABLE3.9 (CONTINUED)

SOLID WASTE SUPPLEMENT NOTE 1:

The total curie quantity and radionuclide composition of solid waste shipped from the St. Lucie Plant, Units 1 and 2 are determined using a combination of qualitative and quantitative techniques.

In general, the St. Lucie Plant follows the guidelines outlined in the Low Level Waste Licensing Branch Technical Position (BTP) on Radioactive Waste Classification (6/11/83) for these determinations.

The most frequently used techniques for determining the total curie quantity in a package are the dose to curie methods and the (concentration) x (volume or mass) calculations.

Where appropriate, engineering type activation analyses may be applied.

Since each of the above methodologies involves to some extent qualitative parameters, the total curie quantity is considered to be an estimate.

The composition of radionuclides in the waste is determined by both on-site analyses for principal gamma emitters and periodic off-site analyses for other radionuclides.

~ The on-site analyses are performed either on a batch basis or on a routine basis using reasonably representative sample as appropriate for the waste type.

Off-site analyses are used to establish scaling factors or other estimates for radionucljdes such as H3, C'", Fe, Nj, Sr', Tc, I',

Pu238 Pu239/240 Pu241 Am241 Cm242 and Cm243/244 NOTE 2:

"Principal Radionuclides" refer to those radionuclides contained in the waste in concentrations greater than 0.01 times the concentration of the nuclides listed in Table 1 or 0.01 times the smallest concentration of the nuclides listed in Table 2 of 10 CFR 61.

NOTE 3:

"Type of Waste" is generally specified as described in NUREG 0782, Draft Environmental Impact Statement on 10 CFR 61, "Licensing Requirements for Land Disposal of Radioactive Waste".

NOTE 4:

"Type of Container" refers to the transport package.

NOTE 6:

The volume and activity listed for Dry Compressible Waste represent the quantity of material that during the reporting period was sent to the Barnwell, South Carolina burial facility.

38

Some of this material was shipped to contracted vendors for volume reduction prior to final disposal at the Barnwell, South Carolina burial facility. During the reporting period, eleven (11) shipments of Dry Compressible Waste and non-compactible wastes

( 21,172 cubic feet, 2.235 curies) were made from the St. Lucie Plant to the volume reduction facilities. These material was shipped via "Sole Use Truck" in non-specification strong tight packages.

NOTE 6 The volume and activity listed for Resins represent the quantity of material that during the reporting period was sent from the St. Lucie Plant to the Barnwell, South Carolina burial facility. During the reporting period, two (2) shipments of Resins ( 1018 cubic feet, 1.03 E-3 curies) were made from the St.Lucie Plant to a volume reduction facility. This material w'as shipped in non-specification strong tight packages.

NOTE 7 One (1) package of contaminated oil ( 336.4 cubic feet, 7.054 E-3 Ci) was shipped from the St. Lucie Plant to a volume reduction facility. This material was shipped in a non-specification strong tight container.

Additionally, four (4) shipments of miscellaneous dry flowable materials (blasting grits, soil, etc., 1673 cubic feet, 1 ~13 E-4 curies) were shipped to a volume reduction facilityfor survey, volume reduction and disposal.

These materials were shipped in non-specification strong tight containers.

39

FLORIDAPOWER 2 LIGHTCOMPANY ST. LUCIEUNIT8 1

~

ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 TABLE3.10 SEWAGE SLUDGE SHIPMENTS Number of Shipments:

2 Sample and analyses by Florida Department of Health and Rehabilitive Services(HRS):

Shipment Number Sam le Date Isoto e conc.

K-40 Mn-54 Co-58 Co-60 Zn-65 Zr-95 Sn-113 1-131 Cs-134 Cs-137 TI-201 TI-202 Ra-226 13-Feb Ci/ m 4.00E-02 1.60E-02 2.63E-01 1.64E-01 1.60E-02 2.30E-02 4.00E-03 O.OOE+00 O.OOE+00 2.20E-02 O.OOE+00 O.OOE+Oo 4.00E-02 19-Nov Ci/gm 6.00E-02 1.90E-02 2.50E-02 3.23E-01 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2.90E-02 O.OOE+00 O.OOE+00 O.OOE+00 FPL Calculated Curies b Shi ment and Total(s):

Shi ment Number Date shi ed 5-Mar 16-Dec Volume in allons 8,000 8,000 Nucl Ci Ci Nucl Ci K-40 Mn-54 Co-58 Co-60 Zn-65 Zr-95 1.22E-06 1.83E-06 3.06E-06 4.89E-07 5.81E-07 1.07E-06 8.04E-06 7.65E-07 8.81E-06 5.02E-06 9.88E-06 1.49E-05 4.89E-07 O.OOE+00 4.89E-07 7.03E-07 0.00E+00 7.03E-07 Sn-113 1.22E-07 O.OOE+Oo 1.22E-07 I-131 O.OOE+00 O.OOE+00 O.OOE+00 Cs-134 O.OOE+00 0.00E+00 O.OOE+00 Cs-137 6.73E-07 8.87E-07 1.56E-06 TI-201 TI-202 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Ra-226 1.22E-06 O.OOE+OO 1.22E-06 Total of all Shi ments 3.19E-05 Ci Total of all Shi ments 1.60E+04 allons 40

FLORIDAPOWER &LIGHTCOMPANY ST. LUCIEUNIT8 1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 Attachment - A UNPLANNEDGaseous Release of August 14, 1996 Pressure Drop from Gas Decay Tank ¹ 1A Due to Valve Not Fully Seated Description of the Event:

St. Lucie Plant Condition Report 96-1993 documents the initial CONDITION, EVALUATION,and CORRECTIVE ACTIONS for this event. The following is a brief summary.

A Senior Nuclear Plant Operator(SNPO) noted that the in-service Gas Decay Tank ¹ 1A was not holding pressure.

Operations reviewed the previous log entries and determined that the tank had dropped 8 psi in the previous 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. Off-normal Operating Procedure ONOP 1-05300313 "Uncontrolled Release of Radioactive Gas" was implemented.

Appropriate radiological surveys and tank samples were obtained.

The system engineer placed a a surgical glove over piping drain valves and discovered that drain valve V06154 for Waste Gas Compressor 1A was leaking slightly. This valve was tightened closed and no more tank leakage occurred.

Causes(s) for the unplanned release:

1) Operations had been requested to open and then shut V06154 on a shiftly basis, to drain any accumulated water in the discharge piping of the 1A Waste Gas Compressor.

This valve cycling was to insure that water accumulation was not the cause for waste gas compressor reliability problem.

2) The valve was stiffto turn since it is not a normally cycled valve.

'3) On one of the open and then shut cycles, while checking forwater accumulation, the valve was thought to be fullyclosed based on hand tightness and the absence of any audible sound of escaping gas from the valve's drain line.

4) The valve was not fullyseated and the slow leak caused the loss of inventory from the inservice gas decay tank of 8 psi over 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

Actions taken to prevent a recurrence:

1. Operations cancelled the shiftly opening of V06154 to check forwater.

No water accumulation had been noted during these checks.

2. A Plant Condition Report was initiated to document the Condition, Evaluate the Event, and initiate Corrective Actions.
3. Operations Training has reiterated gas valve operations during the Non-Licensed Operator Requalification Training during the 96.05 training cycle.
4. Plant Management directed that the compressor drain valve exit pipes be capped.
5. The Facility Review Group reviewed this UNPLANNEDRELEASE and Corrective Actions per Technical Specification 6.5.1.6.k.

41

r a

FLORIDAPOWER &LIGHTCOMPANY ST. LUCIEUNIT8 1 ANNUALREPORT JANUARY 1, 1996 THROUGH DECEMBER 31, 1996 Attachment - A (continued)

UNPLANNEDGaseous Release of August 14, 1996 Consequences of the unplanned release:

Based on Tank Grab Samples and calculated release volume, the release was:

Nuclide S mbol Xe-133 H-3 Particulate lodines Assay uCi/cc 2.89E-04 1.43E-06

< M.D.A

< M.D.A Release Curies 1.04E-03 5.15E-06 O.OOE+00 0.00E+00 Release Volume 3.61E+06 cc.s The release path was from the drain valve to the Reactor AuxiliaryBuilding atmoshpere, which exhaust through the Reactor AuxiliaryBuilding Plant Vent, a monitored effluent pathway.

No alarms were received during this event due to the low activity present in the Gas Decay Tank and the slow release rate of 1.14E-01 SCFM. No C-200 ODCM Control Limits were exceeded during this event.

42