l~

St. Lucie Units I and 2 Docket Nos. 50-335 and 50-389 L-99-046 Enclosure 1

FLORIDA POWER & LIGHTCOMPANY ST. LUCIE PLANT UNITS NO. 1 & 2 LICENSE NUMBERS DPR-67 & NPF-16 COMBINEDANNUALRADIOACTIVEEFFLUENT RELEASE REPORT FOR THE PERIOD JANUARY1, 1998 THROUGH DECEMBER 31, 1998 f

99030'70159 990226 PDR ADOCK 05000335 I

j, R

PDR

TABLE OF CONTENTS DESCRIPTION PAGE EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION.

VISITOR DOSE RESULTS FOR CALENDARYEAR 1998 OFFSITE DOSE CALCULATIONMANUALREVISIONS SOLID WASTE AND IRRADIATEDFUEL SHIPMENTS PROCESS CONTROL PROGRAM REVISIONS LIQUIDEFFLUENTS:

Summation of all Releases Summation of all Releases Nuclide Summation by Quarter Nuclide Summation by Quarter Liquid Effluent Dose Liquid Effluent Dose GASEOUS EFFLUENT:

Unit ¹1.

Unit ¹2 Unit¹1.

Unit ¹2 Unit¹1.

Unit ¹2 7

9 11 15 19 20 Summation of all Releases Summation of all Releases Nuclide Summation by Quarter Nuclide Summation by Quarter Gas Effluent Dose Gas Effluent Dose Unit ¹1 Unit¹ 2 Unit ¹1 Unit¹ 2 Unit ¹1 Unit ¹2 21 23 25 29 33 34 SOLID WASTE DISPOSAL - TABLE 3.9 Shipment Summations.....

Attachment - A ODCM Table 4.11-2 "Continuous" Sample Collection Deviation 35 39

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION

1. Regulatory Limits 1.1 For Liquid Waste Effluents A. The concentration of radioactive material released from the site shall be limited to ten times the concentrations specified in 10 CFR Part 20 Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases.

For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 micro-Curies/ml total activity.

B. The dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive material in liquid effluents released, from each reactor unit, to UNRESTRICTED AREAS shall be limited to:

during any calendar quarter to <= 1.5 mrems to the Total Body and to <= 5 mrems to any organ, and during any calendar year to

<= 3 mrems to the Total Body and to <= 10 mrems to any organ.

1.2 For Gaseous Waste Effluents:

A. The dose rate in UNRESTRICTED AREAS due to radioactive materials released in gaseous effluents from the site shall be limited to:

For Noble Gases: <= 500 mrems/yr to the total body and

<= 3000 mrems/yr to the skin, and For Iodine-131, Iodine-133, Tritium, and all radionuclides in particulate form with half-lives greater than 8 days:

<= 1500 mrems/yr to any organ.

  • B. The air dose due to noble gases released in gaseous effluents from each unit, to areas at and beyond the SITE BOUNDARY shall be limited to the following:

during any calendar quarter, to <= 5 mrads for gamma radiation, and

<= 10 mrads for beta radiation and during any calendar year, to <= 10 mrads for gamma radiation and

<= 20 mrads for beta radiation.

  • C. The dose to a MEMBER OF THE PUBLIC from Iodine-131, Iodine-133, Tritium, and all radionuclides in particulate form, with half-lives > 8 days in gaseous effluents released, from each unit to areas at and beyond the site boundary, shall be limited to the following:

during any calendar quarter to <= 7.5 mrem to any organ, and during any calendar year to

<= 15 mrem to any organ.

  • The calculated doses contained in an annual report shall not apply to any ODCM control. The reported values are based on actual release conditions instead of historical conditions that the ODCM control dose calculations are based on. The ODCM control dose limits are, therefore, included in Item 1 of the report for information only.

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION(Continued)

2. Effluent Concentration Limits (ECL)

Water: Ten times the 10 CFR Part 20, Appendix B, Table 2, Column 2, except for entrained or dissolved noble gases as described in 1.1.A of this report.

Air:

Release concentrations are limited to dose rate limits described in 1.2.A. of this report.

3. Average Energy of fission and activation gases in gaseous effluents is not applicable.
4. Measurements and approximations of total radioactivity Where alpha, tritium, and listed nuclides are shown as zero Curies released, this should be interpreted as "no activity was detected on the samples using the ODCM control analyses techniques to achieve required Lower Limit of Detection (LLD)sensitivity for radioactive effluents".

A summary of liquid effluent accounting methods is described in Table 3.1.

A summary of gaseous effluent accounting methods is described in Table 3.2.

4.1 Estimate of Errors Error To ic Release Point Mixin Sampling Sam le Preparation Sample Anal sis A

LIQUID Max %

10 Av GASEOUS Max %

10 Release Volume Total Percent 30 10 15 35 The predictability of error for radioactive releases can only be applied to nuclides that are predominant in sample spectrums.

Nuclides that are near background relative to the predominant nuclides in a given sample could easily have errors greater than the above listed maximums.

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION(Continued)

4. Measurements and Approximations of Total Radioactivity (Cont.)

4.2 Methods of Analyses TABLE 3.1 RADIOACTIVELIQUIDEFFLUENT SAMPLINGANDANALYSIS Liquid Source Sampling Frequenc T

eofAnal sis Method of Anal sis Each Batch Principal Gamma Emitters P.H.A.

Monitor Tank Releases Monthly Composite Quarterly Composite Tritium Gross AI ha Sr-89, Sr-90,

& Fe-55 L.S.

G.F.P.

C.S.

Continuous Releases Daily Grab Samples Principal Gamma Emitters

& I-131 for 4/M Composite Anal sis Dissolved & Entrained Gases One Batch/ Month Tritium Composite Monthl Alpha Com osite Monthl P.H.A.

P.H.A.

L.S.

G.F.P.

Sr-89, Sr-90, & Fe-55 Com osite Quarterl C.S.

P.H.A.-

L.S.-

C.S.-

G.F.P.-

4/M-Gamma Spectrum Pulse Height Analysis using Germanium Detectors.

Allpeaks are identified and quantified.

Liquid Scintillation Counting Chemical Separation Gas Flow Proportional Counting Four per Month

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION(Continued)

4. Measurements and Approximations of Total Radioactivity (Continued) 4.2 Methods of Analyses(Continued)

TABLE 3:2 RADIOACTIVEGASEOUS WASTE.SAMPLING AND ANALYSIS Gaseous Source Sampling Frequenc T

e of Anal sis Method of Anal sis Waste Gas Decay Tank Releases Each Batch Principal Gamma Emitters P.H.A.

Containment Purge Releases Each Purge Principal Gamma Emitters Tritium P.H.A.

L.S.

4/M Principal Gamma Emitters Tritium P.H.A.

L.S.

Plant Vent Monthly Composite Particulate Gross Alpha G.F.P.

Quarterly Composite Particulate Sr-89 8 Sr-90 C.S.

P.H.A.- Gamma Spectrum Pulse Height Analysis using Germanium Detectors.

All peaks are identified and quantified.

L.S.- Liquid Scintillation Counting C.S.- Chemical Separation G.F.P.- Gas Flow Proportional Counting 4/M - Four per Month

FLORIDA POWER 8'. LIGHTCOMPANY ST. LUCIE UNIT4 1 8: 2 AX>i'UALREPORT JANUARY I, 1993 THROUGH DECEMBER 31, 199S EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION(Continued) 5.

Batch Releases A. Liquid Unit 1 Unit 2 Eng. Unit

1. Number of batch releases
2. Total time period for batch releases
3. Maximum time period for a batch release
4. Average time period for a batch release
5. Minimum time period for a batch release
6. Average dilution stream flow during the period All liquid releases are summarized in Tables 32 18,769 1,985 587 193 31 18,165 1,985 586 193 minutes minutes minutes minutes 1,007,465 1,007,465 gpm B. Gaseous Unit 1 Unit 2 Eng. Unit
1. Number of batch releases
2. Total time period for batch releases
3. Maximum time period for a batch release
4. Average time period for a batch release
5. Minimum time period for a batch release Allgaseous waste releases are summarized in Tables 29 93,720 2,838 323 75 86 12,001 3,143 135 40 minutes minutes minutes minutes 6.

Unplanned Releases A. Liquid

1. Number of releases
2. Total activity of releases Unit 1 Unit 2 Eng. Unit 0

0 0.00E+00 0.00E+00 Curies B. Gaseous

1. Number of releases
2. Total activity of releases Unit 1 Unit 2 Eng. Unit 0

0 0.00E+00 0.00E+00 Curies C. see attachments (ifapplicable) for:

1. A description of the event and equipment involved.
2. Cause(s) for the unplanned release.
3. Actions taken to prevent a recurrence.
4. Consequences of the unplanned release.

EFFLUENT AND WASTE DISPOSAL SUPPLEMENTAL INFORMATION(Continued) 7.

Assessment of radiation dose from radioactive effiuents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARYassumes the VISITOR onsite for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> per day for 312 days per year at a distance of 1.6 kilometers in the South East Sector.

The VISITOR received exposure from each of the two reactors on the Site.

VISITOR DOSE RESULTS FOR CALENDARYEAR 1998 were:

DOSE Gas Particulate mrad 8 Iodine Dose 1.06E-04 Bone 6.19E-05 Liver Thyroid Kidney Lung Gl-LLI Total Body Dose mrem 3.71E-07 2.51E-04 3.00E-04 1.10E-04 2.51E-04 2.51E-04 2.53E-04 8.

Offsite Dose Calculation Manual (ODCM) Revision(s):

C-200, ODCM Revision 20 was implemented during the reporting period.

ODCM Control 3/4.12.3 Surveillance 4.12.3 requires that the Interlaboratory Comparison Program be described in the ODCM ifthe Program is other than the program conducted by the EPA. Appendix D, Description of the Interlaboratoiy Comparison Program (ICP) was added to the ODCM to fulfillthis requirement.

Appendix D describes sample matrices, acceptable matrice sample suppliers, acceptance tolerances for results, and the frequency for performing comparisons.

This change ensures that the ICP program willinclude matrices that can no longer be obtained through the EPA.

Dose factor tables and dose calculation steps were added for the CHILD and TEEN age groups for Fish-Shellfish pathways.

Dose Factor tables and dose calculation steps were added for the CHILD, TEEN, and ADULTfor Grass-Cow-Milk, Meat Animal, and Garden pathways.

Calculation of dose for these pathways and age groups had previously been performed using NUREG 0133.

The NUREG 0133 instruction and methodology is now captured in the ODCM to ensure that all age groups and their respective pathways are formally identified in plant procedures so that it is clear on how to perform the ODCM required 2 year dose assessment for all age groups (to determine the controlling age group for ODCM usage).

The added dose factors use NUREG 0133/RG 1.109 default assumptions in lieu of site specific data.

9.

Solid Waste and Irradiated Fuel Shipments:

No irradiated fuel shipments were made from the site.

Common Solid waste from St. Lucie Units 1 and 2 were shipped jointly.

A tabulated summation of these shipments is provided in this report as Table 3.9.

10. Process Control Program (PCP) Revisions:

Administrative Procedure 0520025, Process Control Program Revision 12 was implemented.

The changes were editorial in nature and did not constitute a change to systems described in either Unit's Update Final safety Analysis Reports.

FLORIDAPOWER 8. LIGHTCOMPANY ST. LUCIE UNIT N 1

AMCJALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.3-1 LIQUIDEFFLUENTS - SUMMATIONOF ALLRELEASES UNIT QTRP1 QTRN2 A. Fission and Activation Products

1. Total Release - (Not including Tritium, Gases, and Alpha)

Ci 7.78E-02 1.67E-02

2. Average Diluted Concentration During Period uCi/ml 1.58E-10 3.34E-11 B. Tritium
1. Total Release Ci 6.03E+01 1.69E+02
2. Average Diluted Concentration During Period uCi/ml 1.22E-07 3.37E-07 C. Dissolved and Entrained Gases
1. Total Release Ci 1.88E-02 2.88E-03
2. Average Diluted Concentration During Period uCi/ml 3.82E-11 5.76E-12 D. Gross Alpha Radioactivity
1. Total Release Ci 1.60E-06 0.00E+00 E. Volume ofWaste Released (Prior to Dilution)

Liters 1.05E+06 5.33E+05 F. Volume ofDilution Water Used During Period Liters 4.93E+11 5.01E+11

FLORIDA POih'ER 8. LIGHTCOMPANY ST. LUCIE UNIT P I

~UALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.3-1 LIQUIDEFFLUENTS - SUMMATIONOF ALLRELEASES(Continued)

A. Fission and Activation Products UNIT QTR43 QTRP4

1. Total Release - (Not including Tritium, Gases, and Alpha)

Ci 5.13E-03 2.50E-02

2. Average Diluted Concentration During Period uCi/ml 9.99E-12 1.28E-11 B. Tritium
1. Total Release Ci 1.00E+02 1.67E+02
2. Average Diluted Concentration During Period uCi/ml 1.95E-07 8.57E-08 C. Dissolved and Entrained Gases
1. Total Release Ci 1.37E-03 4.94E-02
2. Average Diluted Concentration During Period uCi/ml 2.67E-12 2.53E-11 D. Gross Alpha Radioactivity
1. Total Release Ci O.OOE+00 O.OOE+00 E. Volume ofWaste Released (Prior to Dilution)

Liters 5.83E+05 1.13E+06 F. Volume ofDilution Water Used During Period Liters 5.14E+11 1.95E+12

FLORIDAPOWER 6; LIGHTCOMPANY ST. LUCIE UNIT0 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.3-2 LIQUIDEFFLUENTS - SUMMATIONOF ALLRELEASES UNIT QTRP1 QTR02 A. Fission and Activation Products

1. Total Release - (Not including Tritium, Gases, and Alpha)

Ci 7.78E-02 1.67E-02

2. Average Diluted Concentration During Period uCi/ml 1.58E-10 3.34E-11 B. Tritium
1. Total Release Ci 6.03E+01 1.69E+02
2. Average Diluted Concentration During Period uCi/ml 1.22E-07 3.37E-07 C. Dissolved and Entrained Gases
1. Total Release Ci 1.88E-02 2.88E-03
2. Average Diluted Concentration During Period uCi/ml 3.82E-11 5.76E-12 D. Gross Alpha Radioactivity
1. Total Release Ci 1.60E-06 0.00E+00 E. Volume ofWaste Released (Prior to Dilution)

Liters 1.05E+06 5.33E+05 F. Volume ofDilutionWater Used During Period Liters 4.93E+11 5.01E+11

FLORIDAPOD'ER 8: LIGHTCOMPANY ST. LUCIE UNIT P 2 ANNUALREPORT JANUARY I, 1998 THROUGH DECEMBER 31, 1998 TABLE3.3-2 LIQUIDEFFLUENTS - SUMMATIONOF ALLRELEASES(Continued)

A. Fission and Activation Products UNIT QTRP3 QTRP4

1. Total Release - (Not including Tritium, Gases, and Alpha)

Ci 5.13E-03 2.50E-02

2. Average Diluted Concentration During Period uCi/ml 9.99E-12 1.28E-I I B. Tritium
1. Total Release Ci 1.00E+02 1.39E+02
2. Average Diluted Concentration During Period uCi/ml 1.95E-07 7.11E-08 C. Dissolved and Entrained Gases I. Total Release Ci 1.37E-03 4.94E-02
2. Average Diluted Concentration During Period uCi/ml 2.67E-12 2.53E-11 D. Gross Alpha Radioactivity
1. Total Release Ci 0.00E+00 0.00E+00 E. Volume ofWaste Released (Prior to Dilution)

Liters 5.83E+05 1.13E+06 F. Volume ofDilution Water Used During Period Liters 5.14E+11 1.95E+12 10

FLORIDAPOWER 8; LIGHTCOMPANY ST. LUCIE UNIT0 1

ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.4-1 LIQUIDEFFLUENTS NUCLIDES RELEASED UNIT Continuous Mode QTR51 QTRP2 Batch Mode QTR01 QTR$2 Na-24 Cr-51 Mn-54 Fe-55 Mn-56 Co-57 Co-58 Fe-59 Co-60 Zn-65 Ni-65 Br-82 Rb-88 Sr-89 Sr-90 Y-90 Sr-91 Sr-92 Y-92 Zr-95 Nb-95 Zr-97 Nb-97 Tc-99m.

Mo-99 Ru-103 Ag-110 Sn-113 Sb-122 Sb-124 Sb-125 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.51E-02 1.34E-03 4.91E-03 0.00E 00 1.67E-04 1.73E-02 1.26E-03 1.50E-02 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 5.23E-07 5.23E-07 0.00E 00 0.00E 00 0.00E 00 4.57E-03 7.43E-03 2.82E-04 2.90E-03 0.00E 00 1.38E-04 0.00E 00 1.78E-03 6.23E-04 0.00E 00 3.40E-04 1.10E-03 0 00E 00 3 47E-04 4.10E-04 5.94E-03 0.00E 00 1.84E-05 1.94E-03 0.00E+00 3.89E-03 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.46E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 5.26E-04 8.06E-04 0.00E 00 8.03E-05 0.00E 00 0.00E 00 0.00E 00 1.77E-04 6.15E-05 3.46E-OS 9.53E-OS 8.78E-04 11

FLORIDAPOWER 8: LIGHTCOMPANY ST. LUCIE UNIT¹ 1

ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.4-1 LIQUIDEFFLUENTS(Continued)

NUCLIDES RELEASED UNIT Continuous Mode QTR¹1 QTR¹2 Batch Mode QTR¹1 QTR¹2 Te-129 Te-129m I-131 Te-132 I-132 I-133 I-134 Cs-134 I-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Ce-141 Ce-144 Pr-144 W-187 Np-239 TOTALFOR PERIOD Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0 00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E+00 0.00E+00 1.85E-03 0.00E 00 0.00E 00 0.00E 00 0.00E 00 9.36E-06 0.00E 00 1.43E-04 1.54E-05 0.00E 00 1.30E-03 0.00E 00 0.00E 00 1.84E-05 0.00E 00 0.00E 00 0.00E 00 1.99E-04 0.00E 00 7.78E-02 7.76E-04 0 00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.46E-04 0.00E 00 0.00E 00 5.93E-04 0.00E 00 0.00E 00 0.00E 00 1.03E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.67E-02 Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-131m

'e-133m Xe-133 Xe-135m Xe-135 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.58E-05 1.67E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.85E-02 3.64E-05 2.53E-04 1.38E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.87E-03 0.00E 00 0.00E+00 12

FLORIDAPOWER 8: LIGHTCOMPANY ST. LUCIEUNIT¹ 1

ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.4-1 LIQUIDEFFLUENTS(Continued)

NUCLIDES RELEASED Na-24 Cr-51 Mn-54 Fe-55 Mn-56 Co-57 Co-58 Fe-59 Co-60 Zn-65 Ni-65 Br-82 Rb-88 Sr-89 Sr-90 Y-90 Sr-91 Sr-92 Y-92 Zr-95 Nb-95 Zr-97 Nb-97 Tc-99m Mo-99 Ru-103 Ag-110 Sn-113 Sb-122 Sb-124 Sb-125 UNIT Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Continuous Mode QTR¹3 QTR¹4 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00'.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 Batch QTR¹3 0.00E 00 0.00E 00 5.91E-05 1.58E-03 0.00E 00 0.00E 00 3.82E-04 0.00E 00 7.00E-04 0.00E 00 0.00E 00 0.00E 00 0.00E 00 9.32E-06 2.39E-06 2.39E-06 0.00E 00 1.17E-04 0.00E 00 8.79E-06 0.00E 00 0.00E 00 0.00E 00 4.82E-06 0.00E 00 0.00E 00 5.43E-05 0.00E 00 4.09E-05 0.00E 00 1.47E-04 Mode QTR¹4 0.00E+00 2.06E-03 2.05E-04 S.SOE-03 0.00E+00 7.25E-06 5.43E-03 3.45E-04 1.90E-03 0 00E+00 0.00E+00 0.00E+00 0 00E+00 1.02E-05 2.38E-06 2.38E-06 0.00E+00 3.31E-05 0 00E+00 1.85E-04 3.14E-04 0.00E+00 1.05E-04 0.00E+00 0.00E+00 1.75E-05 1.81E-03 1.86E-04 9.70E-06 1.42E-04 1.79E-03 13

FLORIDAPOWER K LIGHTCOMPANY ST. LUCIEUNIT4 1

ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.4-1 LIQUIDEFFLUENTS (continued)

NUCLIDES RELEASED Te-129 Te-129m I-130 I-131 Te-132 I-132 I-133 I-134 Cs-134 I-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Ce-141 Ce-144 Pr-144 W-187 Np-239 TOTALFOR PERIOD UNIT Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Continuous Mode QTRN3 QTRW 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E+00 0.00E+00 Batch QTRN3 0.00E 00 0.00E 00 0 00E 00 7.25E-06 0.00E 00 7.31E-06 9.65E-06 0.00E 00 3.52E-04 0.00E 00 0.00E 00 1.65E-03 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 5.13E-03 Mode QTRA 7 07E-04 0 00E 00 1.28E-04 3.71E-05 4 45E-05 1.73E-05 1.08E-05 0.00E 00 4.85E-05 0.00E+00 0.00E 00 3.11E-04 1.49E-04 0.00E 00 1.69E-04 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.50E-02 Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-138 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.35E-03 2.04E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.89E-05 1.23E-03 4.64E-04 4.75E-02 1.69E-05 4.87E-05 6.48E-05 14

FLORIDAPOWER 8 LIGHTCOMPANY ST. LUCIEUNIT0 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.4-2 LIQUIDEFFLUENTS NUCLIDES RELEASED Na-24 Cr-51 Mn-54 Fe-55 Mn-56 Co-57 Co-58 Fe-59 Co-60 Zn-65 Ni-65 Br-82 Rb-88 Sr-89 Sr-90 Y-90 Sr-91 Sr-92 Y-92 Zr-95 Nb-95 Zr-97 Nb-97 Tc-99m Mo-99 RU-103 Ag-110 Sn-113 Sb-122 Sb-124 Sb-125 UNIT Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Continuous Mode QTRP1 QTR52 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 Batch QTR41 0.00E 00 1.51E-02 1.34E-03 4.91E-03 0.00E 00 1.67E-04 1.73E-02 1.26E-03 1.50E-02 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 5.23E-07 5.23E-07 0.00E 00 0.00E 00 0.00E 00 4.57E-03 7.43E-03 2.82E-04 2.90E-03 0.00E 00 1.38E-04 0.00E 00 1.78E-03 6.23E-04 0.00E 00 3.40E-04 1.10E-03 Mode QTRP2 0.00E+00 3 47E-04 4.10E-04 5.94E-03 0.00E 00 1.84E-05 1.94E-03 0.00E 00 3.89E-03 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.46E-05 0.00E 00 0 00E 00 0.00E 00 0.00E 00 0 00E 00 5.26E-04 8.06E-04 0.00E 00 8.03E-05 0.00E 00 0.00E 00 0.00E 00 1.77E-04 6.15E-05 3.46E-OS 9.53E-05 8.78E-04 15

FLORIDAPOWER 8; LIGHTCOMPANY ST. LUCIEUNIT N 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.4-2 LIQUIDEFFLUENTS(Continued)

NUCLIDES RELEASED UNIT Continuous Mode QTRN1 QTRN2 Batch Mode QTR¹1 QTRN2 Te-129 Te-129m I-131 Te-132 I-132 I-133 I-134 Cs-134 I-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Ce-141 Ce-144 Pr-144 W-187 Np-239 TOTALFOR PERIOD Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E+00 0.00E+00 1.85E-03 0.00E 00 0.00E 00 2.32E-05 0.00E 00 9.30E-06 0.00E 00 1.43E-04 1.54E-05 0.00E 00 1.30E-03 0.00E 00 0.00E 00 1.84E-05 0.00E 00 0.00E 00 0.00E 00 1.99E-04 0.00E 00 7.78E-02 7.76E-04 0.00E 00 0 00E 00 0 00E 00 0.00E 00 0.00E 00 0 00E 00 1.46E-04 0 00E 00 0.00E 00 5.93E-04 0.00E 00 0 00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.67E-02 Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.50E-05 1.67E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.85E-02 3.64E-05 2.53E-04 1.38E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.87E-03 0.00E 00 0.00E 00 16

FLORIDAPOWER 8: LIGHTCOMPANY ST. LUCIEUNIT0 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.4-2 LIQUIDEFFLUENTS(Continued)

NUCLIDES RELEASED Na-24 Cr-51 Mn-54 Fe-55 Mn-56 Co-57 Co;58 Fe-59 Co-60 Zn-65 Ni-65 Br-82 Rb-88 Sr-89 Sr-90 Y-90 Sr-91 Sr-92 Y-92 Zr-95 Nb-95 Zr-97 Nb-97 Tc-99m Mo-99 Ru-103 Ag-110 Sn-113 Sb-122 Sb-124 Sb-125 UNIT Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Continuous Mode QTR03 QTR~A 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 Batch QTRF3 0.00E 00 0.00E 00 5.91E-05 1.58E-03 0.00E 00 0.00E 00 3.82E-04 0.00E 00 7.00E-04 0.00E 00 0.00E 00 0.00E 00 0.00E 00 9.32E-06 2.39E-06 2.39E-06 0.00E 00 1.17E-04 0.00E 00 8.79E-06 0.00E 00 0.00E 00 0.00E 00 4.82E-06 0.00E 00 0.00E 00 5.43E-05 0.00E 00 4.09E-05 0.00E 00 1.47E-04 Mode QTRP4 0.00E+00 2.06E-03 2.05E-04 8.80E-03 0.00E+00 7.25E-06 5.43E-03 3.45E-04 1.90E-03 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.02E-05 2.38E-06 2.38E-06 0.00E+00 3.31E-05 0.00E+00 1.85E-04 3.14E-04 0.00E+00 1.05E-04 0.00E+00 0.00E+00 1.75E-05 1.81E-03 1.86E-04 9.70E-06 1.42E-04 1.79E-03 17

FLORIDAPOWER 8. LIGHT COMPAM'T.

LUCIE UMT~ 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.4-2 LIQUIDEFFLUENTS(Continued)

NUCLIDES RELEASED Te-129 Te-129m I-130 I-131 Te-132 I-132 I-133 I-134 Cs-134 I-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Ce-141 Ce-144 Pr-144 W-187 Np-239 TOTALFOR PERIOD UNIT Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Continuous Mode QTRN3 QTRN4 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E+00 0.00E+00 Batch QTRu3 0.00E 00 0.00E 00 0 00E 00 7.25E-06 0.00E 00 7.31E-06 9.65E-06 0.00E 00 3.52E-04 0.00E 00 0.00E 00 1.65E-03 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 5.13E-03 Mode QTRN 7.07E-04 0.00E 00 1.28E-04 3.71E-05 4.45E-05 1.73E-05 1.08E-05 0.00E 00 4.85E-05 0.00E+00 0.00E 00 3.11E-04 1.49E-04 0.00E 00 1.69E-04 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.50E-02 Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-138 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 18 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.35E-03 2.04E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.89E-05 1.23E-03 4.64E-04 4.75E-02 1.69E-05 4.87E-05 6.48E-05

FLORIDAPOWER &LIGHTCOMPANY ST. LUCIE UNIT¹ 1

ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31. 1998 TABLE 3.5-1 LIQUIDEFFLUENTS - DOSE SUMMATION AGE GROUP:

ADULT LOCATION:

ANYADULT FISH AND SHELLFISH ORGAN DOSE mrem Bone 1.18E-02 Liver 5.22E-02 Thyroid Kidney 8.27E-04 9.68E-04 Lung 5.89E-02 Gl-LLI Total Body 9.83E-02 1.50E-02 19

FLORIDAPOWER 8 LIGHTCOMPANY ST. LUCIEUNIT0 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE 3.5-2 LIQUIDEFFLUENTS - DOSE SUMMATION AGE GROUP:

ADULT LOCATION:

ANYADULT FISH AND SHELLFISH ORGAN DOSE mrem Bone 1.18E-02 Liver 5.22E-02 Thyroid Kidney 8.27E-04 9.68E-04 Lung 5.89E-02 Gl-LLI Total Body 9.83E-02 1.50E-02 20

FLORIDAPOWER 8 LIGHTCOMPANY ST. LUCIE UNIT0 1

ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.6-1 GASEOUS EFFLUENTS - SUMMATIONOF ALLRELEASES A. Fission and Activation Gases UMT QTRP1 QTRP2

1. Total Release Ci 3.SSE-01 1.30E-01
2. Average Release Rate For Period uCi/sec 4.S9E-02 1.65E-02 B. Iodines
1. Total Iodine-131 Ci 0.00E 00 0.00E 00
2. Average Release Rate For Period uCi/sec 0.00E+00 0.00E+00
1. Particulates (HalfLife> 8 days)

Ci 4.27E-06 3.3 8E-07

2. Average Release Rate For Period uCi/sec SA3E-07 4.30E-08
3. Gross Alpha Radioactivity Ci 6.37E-08 5.08E-08 D. Tritium
1. Total Release Ci 1.18E+01 5.97E+00
2. Average Release Rate For Period uCi/sec 1.50E+00 7.59E-01 21

FL'ORIDAPOWER 4 LIGHTCOMPANY ST. LUCIEUNIT0 1

ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.6-1 GASEOUS EFFLUEblTS - SUMMATIONOF ALLRELEASES(Continued)

A. Fission and Activation Gases UNIT QTRN3 QTRA

1. Total Release Ci 0.00E+00 2.34E-01
2. Average Release Rate For Period uCi/sec 0.00E+00 2.97E-02 B. Iodines
1. Total Iodine-131 Ci 0.00E00 0.00E00
2. Average Release Rate For Period uCi/sec 0.00E+00 0.00E+00 C. Particulates
1. Particulates (HalfLife> 8 days)

Ci 1.37E-06 5.60E-07

2. Average Release Rate For Period uCi/sec 1.74E-07 7.12E-08
3. Gross Alpha Radioactivity Ci 0.00E+00 8.06E-08 D. Tritium
1. Total Release Ci 7.04E-01 2.30E+01
2. Average Release Rate For Period uCi/sec 8.95E-02 2.93E+00 22

FLORIDAPOWER Ec LIGHTCOMPANY ST. LUCIEUNIT N 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.6-2 GASEOUS EFFLUENTS - SUMMATIONOF ALLRELEASES A. Fission and Activation Gases UNIT QTRP1 QTR02

1. Total Release Ci 3.77E-01 2.13E+00
2. Average Release Rate For Period uCi/sec 4.80E-02 2.71E-01 B. Iodines
1. Total Iodine-131 Ci 4.95E-06 1.54E-05
2. Average Release Rate For Period uCi/sec 6.37E-07 1.96E-06 C. Particulates
1. Particulates (HalfLife> 8 days)

Ci 3.47E-06 1.46E-05

2. Average Release Rate For Period uCi/sec 4.41E-07 1.86E-06
3. Gross Alpha Radioactivity Ci 8.95E-08 9.73E-08 D. Tritium
1. Total Release Ci 5.20E+00 9.92E+00
2. Average Release Rate For Period uCi/sec 6.61E-01 1.26E+00 23

FLORIDAPOWER 9; LIGHTCOMPANY ST. LUCIEUNIT N 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE'3.6-2 GASEOUS EFFLUENTS - SUMMATIONOF ALLRELEASES(Continued)

A. Fission and Activation Gases UNIT QTRN3 QTR~A

1. Total Release Ci 3.51E-O I 1.55E+00
2. Average Release Rate For Period uCi/sec 4.47E-02 1.97E-01 B. Iodines
1. Total Iodine-131 Ci 1.48E-05 1.86E-05
2. Average Release Rate For Period uCi/sec 0.00E+00 0.00E+00
1. Particulates (HalfLife> 8 days)

Ci 2.52E-06 9.84E-06

2. Average Release Rate For Period uCi/sec 3.21E-07 1.25E-06
3. Gross Alpha Radioactivity Ci 6.34E-08 1.48E-07 D. Tritium
1. Total Release Ci 9.45E+00 3.19E+01
2. Average Release Rate For Period uCi/sec 1.20E+00 4.06E+00 24

FLORIDAPOWER 8 LIGHTCOMPANY ST. LUCIE UNIT¹ 1 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.7-1 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Nuclides Released Unit Continuous Mode QTR¹1 QTR¹2 Batch Mode QTR¹1 QTR¹2

1. Fission Gases Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-127 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E+00 0.00E+00 1.02E-OI O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 O.OOE 00 2.68E-OI O.OOE 00 1.46E-02 0.00E 00 O.OOE 00 3.85E-01 O.OOE 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0 OOE 00 O.OOE 00 0.00E 00 0.00E 00 1.30E-OI O.OOE 00 0.00E 00 O.OOE 00 0 OOE 00 1.30E-01
2. Iodines I-131 l-132 I-133 I-134 I-135 Total for Period Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 4.11E-05 1.46E-04 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 4.11E-05 1.46E-04
3. Particulates (>8 Days)

Cr-51 Mn-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Zr-95 Nb-95 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 2.71E-08 0.00E 00 1.59E-07 1.93E-07 0.00E 00 2.05E-07 0.00E 00 3.38E-07 1.89E-07 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 25

FLORIDAPOWER &'LIGHTCOMPANY ST. LUCIE UNIT¹ 1 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.7-1 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES(Continued)

Nuclides Released

3. Particulates

( > 8 Days) (co Continuous Mode QTR¹1 QTR¹2 ntinued)

Sr-89 Sr-90 Y-90 Ru-103 Ag-110 Sn-113 Sb-124 Sb-125 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Te-129m Cs-134 Cs-136 Cs-137 Ba-140 Ce-141 Ce-144 Total for Period

4. Particulates (< 8 Days) 1.12E-06 1.36E-07 1.36E-07 0.00E 00 0.00E 00 1.59E-07 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.61E-06 0.00E 00 0.00E 00 O.OOE 00 4.27E-06 3.38E-07 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 3.38E-07 Mn-56 Ni-65 Br-82 Rb-88 Rb-89 Sr-91 Sr-92 Y-92 Zr-97 Nb-97 Tc-99m Mo-99 Sb-122 Te-129 Te-132 Cs-138 La-140 Pr-144 W-187 Np-239 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci O.OOE 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 O.OOE+00 0.00E 00 O.OOE 00 0.00E 00 O.OOE 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 O.OOE 00 O.OOE 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE+00 26

FLORIDAPOWER & LIGHTCOMPANY ST. LUCIE UNIT¹ 1 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.7-1 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES(Continued)

Nuclides Released Unit Continuous Mode QTR¹3 QTR¹4 Batch Mode QTR¹3 QTR¹4 Total for P

2. Iodines I-131 1-132 I-133 l-134 I-135 Total for Period
1. Fission Gases Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-127 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 eriod Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 O.OOE+00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 O.OOE+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E+00 0.00E 00 O.OOE 00 9.60E-05 0.00E 00 0.00E 00 9.60E-05 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE+00 O.OOE 00 0.00E 00 2.18E-01 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.62E-02 0.00E 00 0.00E 00 0.00E 00 0.00E 00 2.34E-01
3. Particulates (> 8 Days)

Cr-51 Mn-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Zr-95 Nb-95 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 27

FLORIDAPOWER 8 LIGHTCOMPANY ST. LUCIE UNIT¹ 1 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE 3.7-1 GASEOUS EFFLUENTS - GROUND LEVELRELEASES(Continued)

Nuclides Released

3. Particulates() 8 D Continuous Mode QTR¹3 QTR¹4 Unit ays) (continued)

Sr-89 Sr-90 Y-90 Ru-103 Ag-110 Sn-113 Sb-124 Sb-125 Te-129m Cs-134 Cs-136 Cs-137 Ba-140 Ce-141 Ce-144 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Total for Period

4. Particulates ((8 Days) 1.08E-06 1.43E-07 1.43E-07 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.37E-06 0.00E 00 2.80E-07 2.80E-07 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 5.60E-07 Mn-56 Ni-65 Br-82 Rb-88 Rb-89 Sr-91 Sr-92 Y-92 Zr-97 Nb-97 Tc-99m Mo-99 Sb-122 Te-129 Te-132 Cs-138 La-140 Pr-144 W-187 Np-239 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE+00 28

FLORIDAPOWER 8: LIGHTCOMPANY ST. LUCIE UNITN 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.7-2 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Nuclides Released Unit Continuous Mode QTR¹1 QTR¹2 Batch Mode QTR¹1 QTR¹2

1. Fission Gases Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-1 27 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE+00 0.00E 00 0.00E 00,.

O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.64E+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 1.64E+00 3.33E-01 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 4.36E-02 0.00E 00 8.54E-04 O.OOE 00 0.00E 00 3.77E-01 1.79E-01 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 3.07E-01 0.00E 00 1.32E-03 0.00E 00 0.00E 00 4.87E-01

2. Iodines I-131 I-132 I-133 l-134 I-135 Total for Period Ci Ci Ci Ci Ci Ci 4.95E-06 1.54E-05 0.00E 00 0.00E 00 9.43E-05 3.38E-04 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 9.93E-05 3.53E-04
3. Particulates () 8 Days)

Cr-51 Mn-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Zr-95 Nb-95 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 29

FLORIDAPOWER 8; LIGHTCOMPANY ST. LUCIEUNIT N 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.7-2 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES(Continued)

Continuous Mode Nuclides Unit QTR01 QTR02 Released

3. Particulates

( > 8 Days) (continued)

Sr-89 Sr-90 Y.-90 Ru-103 Ag-110 Sn-113 Sb-124 Sb-125 Te-129m Cs-134 Cs-136 Cs-137 Ba-140 Ce-141 Ce-144 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Total for Period

4. Particulates (<8 Days) 1.20E-06 1.14E-06 1.14E-06 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 3.48E-06 1.03E-05 2.35E-07 2.35E-07 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 3.82E-06 0.00E 00 0.00E 00 O.OOE 00 1.46E-05 Mn-56 Ni-65 Br-82 Rb-88 Rb-89 Sr-91 Sr-92 Y-92 Zr-97 Nb-97 Tc-99m Mo-99 Sb-122 Te-129 Te-132 Cs-138 La-140 Pr-144 W-187 Np-239 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 O.OOE+00 30

FLORIDAPOWER & LIGHTCOMPANY ST. LUCIEUNIT¹ 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 199S TABLE3.7-2 GASEOUS EFFLUENTS - GROUND LEVELRELEASES(Continued)

Nuclides Released Unit Continuous Mode QTR¹3 QTR¹4 Batch Mode QTR¹3 QTR¹4

1. Fission Gases Ar<1 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-127 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 O.OOE+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E+00 1.58E-01 8.93E-05 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 2.84E-03 0.00E 00 1.89E-01 0.00E 00 1.13E-03 0.00E 00 0.00E 00 3.51E-01 7.78E-01 O.OOE 00

-0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 5.90E-03 1.22E-02 7.32E-01 0.00E 00 2.48E-02 0.00E 00 0.00E 00 1.55E+00

2. lodines I-131 l-132 1-133 I-134 l-135 Total for Period Ci Ci Ci Ci Ci Ci 1.48E-05 0.00E 00 3.85E-04 0.00E 00 0.00E 00 4.00E-04 1.86E-05 0.00E 00 4.93E-04 0.00E 00 0.00E 00 5.12E-04
3. Particulates (> 8 Cr-51 Mn-54 Fe-55 Co-57 Co-58 Fe-59 Co-60 Zn-65 Zr-95 Nb-95 Days)

Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 31

FLORIDAPOWER 8. LIGHTCOMPANY ST. LUCIEUNITN 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.7-2 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES(Continued)

Continuous Mode Nuclides Unit QTR¹3 QTR¹4 Released

3. Particulates

( > 8 Days) (continued)

Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Sr-89 Sr-90 Y-90 Ru-103 Ag-110 Sn-113 Sb-124 Sb-125 Te-129m Cs-134 Cs-136 Cs-137 Ba-140 Ce-141 Ce-144 Total for Period

4. Particulates (<8 Days) 2.52E-06 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE 00 0.00E 00 2.52E-06 8.52E-06 6.58E-07 6.58E-07 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 9.84E-06 Mn-56 Ni-65 Br-82 Rb-88 Rb-89 Sr-91 Sr-92 Y-92 Zr-97 Nb-97 Tc-99m Mo-99 Sb-122 Te-129 Te-132 Cs-138 La-140 Pr-144 W-187 Np-239 Total for Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 O.OOE+00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 0.00E 00 O.OOE+00 32

FLORIDAPOWER 8; LIGHTCOMPANY ST. LUCIE UNITN 1

ANNUALREPORT JANUARY 1, 1998 THROUGH DECEiVIBER 31, 1998 TABLE 3.8-1 GASEOUS EFFLUENTS - DOSE SUMMATION AGE GROUP:

INFANT Pathwa Ground Plane(a)

Bone Liver mrem mrem Thyroid mrem Kidney mrem Cow - Milk (b)

Inhalation (a)

Total 4.24E-06 1.91E-04 2.53E-04 1.64E-07 2.36E-04 2.53E-04 4.40E-06 4.27E-04 5.06E-04 8.29E-05 1.03E-04 1.86E-04 Pathway Ground Plane (a)

Lung mrem Gl-LLI mrem T. Body mrem 1.55E-06 Total 4.25E-04 4.25E-04 Cow - Milk (b) 1.89E-04 1.89E-04 Inhalation (a) 2.36E-04 2.36E-04 1.89E-04 2.36E-04 4.27E-04 (a) Sector:

SE (b) Sector:

W Range:

Range:

1.50 miles 4.25 miles(default milk animal)

Noble Gases Gamma AirDose Beta AirDose mrad 1.76E-05 1.92E-05 Sector:

SE Range:

1.5 miles 33

FLORIDAPOWER 8: LIGHTCOMPANY ST. LUCIEUNIT0 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 199S TABLE3.8-2 GASEOUS EFFLUENTS - DOSE SUMMATION AGE GROUP:

INFANT Pathwa Ground Plane(a)

Cow - Milk (b)

Inhalation (a)

Total Bone Liver mrem mrem 1.91E-05 2.65E-04 6.59E-07 3.21E-04 1.98E-05 5.86E-04 Thyroid Kidney mrem mrem 1.48E-03 1.14E-04 4.11E-04 1.40E-04 1.89E-03 2.54E-04 Pathwa Ground Plane(a)

Lung mrem Gl-LLI mrem Inhalation (a) 3.22E-04 3.21E-04 Total 5.79E-04 5.78E-04 Cow - Milk (b) 2.57E-04 2.57E-04 T. Body mrem 3.07E-06 2.60E-04 3.21E-04 5.84E-04 (a) Sector:

SE (b) Sector: W Range:

Range:

1.50 miles 4.25 miles(default)

Noble Gases mrad Gamma AirDose Beta AirDose Sector:

SE 2.27E-04 1.24E-04 Range:

1.5 miles 34

FLORIDAPOWER AND LIGHTCOMPANY ST. LUCIE UNIT¹1 &2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.9 A.

Solid Waste Shipped Off-Site for Burial or Disposal

1. Type of Waste a.

Spent Resins 8 Process Filters Unit M

Ci 12 Month Period 2.50E+01 1.08E+02 Error %

2.0E+01 b.

Dry Compressible Waste (Note 5) c.

Irradiated Components M

Ci M

Ci 6.90E+01 7.26E+00 0.00E+00 O.OOE+00 2.0E+01

2. Solidified Plating Solution M

Ci d.

Other

1. Steam Generators M'i 5.39E+02 1.52E+03 2.12E+00 2.63E-04 2.0E+01 2.0E+01
2. Estimate of Major Nuclide Composition (By Waste Type)

Category a.

Nuclides Fe 55 Ni 63 Co 60 Cs 137 Co 58 Mn 54 Sb 125 C14 I 131 Zr 95 3.65E+01 2.39E+01 2.14E+01 7.22E+00 4.65E+00 1.01E+00 9.00E-01 8.40E-01 7.80E-01 4.40E-01 Ni 63 Co 58 Fe 55 Co 60 Mn 54 Cs 137 Sb 125 Cs 134 C 14 Co 57 3.20E+01 2.50E+01 1.67E+01 1.44E+01 3.61E+00 2.74E+00 2.05E+00 1.49E+00 5.70E-01 5.70E-01 N/A N/A 35

FLORIDAPOWER AND LIGHTCOMPANY ST. LUCIE UNIT¹1 8 2 ANNUALREPORT JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE3.9 (continued)

= 2. Estimate of Major Nuclide Composition (Continued) d.1.

Co 60 Fe 55 Co 58 Ni 63 Ru 106 Cr 51 Nb 95 Mn 54 Zr 95 Sb 125 4.49E+01 2.95E+01 1.28E+01 2.97E+00 1.69E+00 1.50E+00 1.42E+00 1.33E+00 7.80E-01 4.70E-01

,.d2

3. Solid Waste Disposition Number of Shipments Co 60 Co 58 Mn 54 Sb 125 Sb 124 Mode of Transportation 4.94E+01 4.30E+01 3.46E+00 2.89E+00 7.00E-01 Destination Sole Use Truck Barnwell Disposal Facility Barnwell, SC Sole Use Self Propelled Transport Vehicle and Barge Barnwell Disposal Facility Barnwell, SC 10 Sole Use Truck GTS-Duratek Oak Ridge, TN Sole Use Truck Sole Use Truck Manufacturing Sciences Corp Oak Ridge, TN Molten Metal Technologies Oak Ridge, TN B.

Irradiated Fuel Shipments Number of Shipments Sole Use Truck Mode of Transportation US Ecology Oak Ridge, TN Destination N/A*

N/A"

  • N/A= Not Applicable 36

FLORIDAPOWER AND LIGHTCOMPANY ST. LUCIE UNITii/ 1 & 2 ANNUALREPORT JANUARY 1, 1998 THROUGHT DECEMBER 31, 1998 TABLE3.9 (CONTINUED)

Waste Total Class Volume Cubic Ft Class A 2234.95 Class A 75 Class A 12.3 Class A 19034 Class A 202.1 Class A 404.2 Class A 202.1 Total Curies (Note 1) 1.745 2.63E-04 1.41E-02 1517.12 5.448 18.209 17.459 Principal Radionuclides (Notes 1 8 2)

N/A N/A N/A Pu241, Tru, Cs137 Ni63 Cs137, Ni63, Sr90 Ni63, Cs137 Ni63, Sr90, Cs137 Type of Waste (Note 3)

PWR Compactible Trash (Note 5)

Solidified Plating Solution PWR lon Exchange Resin PWR Steam Generators PWR Compactible Trash PWR lon Exchange Resins PWR lon Exchange Resins Reg. Guide 1.21 Category 1.b.

1.d.2 1.a.

1.d.1 1.b.

1.a.

1.a.

Type of Container (Note 4)

Non-Specification Strong Tight Container Non-Specification Strong Tight Container Non-Specification Strong Tight Container Unpackaged DOT-E11912 NRC Certified LSA, Type A NRC Certified LSA, Type A NRC Certified LSA, > Type A Solidification Agent None Cement None None None None None Class A 132.4 Class B 132.4 11.7 60.984 Ni63, Sr90, Cs137 C14 PWR lon Exchange Resins C14, Ni63, Sr90, Cs137 PWR lon Exchange Sum of Nuclides Resins T1/2<5Years 1.a.

1.a.

NRC Certified Type B NRC Certified Type B None None Page 37

FLORIDA POWER AND LIGHT COMPANY ST. LUCIE UNIT¹1 &2 JANUARY 1, 1998 THROUGH DECEMBER 31, 1998 TABLE 3.9 (CONTINUED)

SOLID WASTE SUPPLEMENT The total radionuclide activity and composition of solid waste shipped from the St. Lucie Plant, Units 1 and 2 are determined using a combination of qualitative techniques.

In general, the St. Lucie Plant follows the guidelines outlined in the Low Level Waste Branch Technical Position (BTP) on Radioactive Waste Classification (5/11/83) for these determinations.

The most frequently used techniques for determining the total activity in a package are the "Dose-to-Curie" method and "Concentration Times Volume or Mass calculations.

Where appropriate, engineering type activation analyses may be applied.

Since each of the above methodologies involve, to some extent, qualitative parameters, the total activity is considered to be an estimate.

The composition of radionuclides in the waste is determined by both on-site analyses for principal gamma emitters and periodic off-site analyses for other radionuclides.

The on-site analyses are performed either on a batch basis or on a routine basis using reasonably representative samples, as appropriate, for the waste type. Off-site analyses are used to establish scaling factors or other estimates for radionuclides such as H', C, Fe,Ni',Sr, Tc I' 'u 'u"'m" Cm',andCm'Principal Radionuclides" refer to those radionuclides contained in the waste in concentrations greater than 0.01 times the concentration of the nuclides listed in Table 1

or 0.01 times the smallest concentration of the nuclides listed in Table 2 of 10 CFR 61.

"Type of Waste" is generally specified as described in NUREG 0782, Draft Environmental Impact Statement on 10 CFR 61, "Licensing Requirements for Land Disposal of Radioactive Waste."

"Type of Container" refers to the transport package.

The volume and activity listed for Dry Compressible Waste represent the quantity of material that, during the reporting period, was sent to the licensed disposal facility. Some of this material was shipped to contract vendors for volume reduction or recycle prior to final disposal at the licensed disposal facility. During the reporting period, twenty-one (21) shipments of dry compactible waste, non-compactible waste, resin and lead blankets (23,092 cubic feet, 1.898 Curies) were made from the St. Lucie Plant to the volume reduction facilities. This material was shipped via "Sole Use Truck" in non-specification strong tight containers or NRC certified cask.

38

0-FLORIDA POWER 8.'IGHT COMPANY ST. LUCIE ANNUALREPORT JANUARY I, 1993 THROUGH DECEMBER 31, I993 Attachment - A Deviation from ODCM Table 4.11-2 Continuous Collection on a Vent Pathway Description of the Event:

On April 8, 1998 the Instrument & Control department was performing a High Range Gas Channel Calibration on Unit 1's Plant Vent Monitorwhen the power supply to the entire sampling skid blew out. This resulted in loss of sample flow to the particulate and charcoal samplers.

The samplers are used to fulfillthe ODCM Table 4.11-2, Radioactive Gaseous Waste Sampling & Analysis Program's "Item 4. All Release Types as listed in 3. Above (Vents) Continuous" sampling for Charcoal and Particulate releases.

The time of the failure was April 8, 1998 at 1530.

Another power supply was installed and the sample flowwas restored on April 8, 1998 at 1834.

Sample collection on the Plant Vent was off for 184 minutes which does not meet the requirement of continuous.

Per ODCM Control 3.3.3.10 Table 3.3-13, Radioactive Gaseous Effluent Monitoring Instrumentation Item 3, Plant Vent System items b) Iodine Sampler and c) Particulate Sampler, ACTION 51 allows effluent releases via the affected pathway to continue for up to 30 days provided samples. are continuously collected with auxiliary sampling equipment as required by ODCM Table 4.11-2.

In this case, it was deemed more expedient to restore the power supply than wait for the heavy auxiliary sampling skid to be brought to the skid's location.

In either case there would have been a short duration loss of continuous sampling interval.

The inoperability was corrected in a timely manner.

Unit 1 was operating with the Gaseous Waste Gas Decay Tanks in service.

The 1998 entire Quarter 2 releases were 0.13 Curies Noble Gas, 1.46E-04 Curies of 1-133, and 3.38E-07 Curies of Particulate with Half Life greater than 8 days. The health and safety of the public was not affected by the 184 minute loss of sample collection.

Causes(s) for the failure:

Plant Condition Report Number CR 98-0622, was generated to investigate the cause.

The Nuclear Plant Work Order package was reviewed for possible cause(s).

It was determined from the Journeymen's Work Report that the "as found" condition of the power supply was "failing."

The calibration procedure was reviewed for possible procedure deficiency.

Procedure 1-IMP-26.15 was used to perform the calibration. The finding of the procedure review was that the procedure was satisfactory for it's intended purpose.

Actions taken to prevent a recurrence:

It was determined that no Generic Action was required.

The apparent cause was normal degradation of the equipment(the power supply).

39

St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 L-99-046 Enclosure 2 ODCM Revision 20