ML17018A104
ML17018A104 | |
Person / Time | |
---|---|
Site: | Vallecitos Nuclear Center |
Issue date: | 02/02/2017 |
From: | Anthony Mendiola Research and Test Reactors Oversight Branch |
To: | Feyrer M GE Hitachi Nuclear Energy |
Anthony Mendiola | |
Shared Package | |
ML16024A325 | List: |
References | |
50-073/OL-17-001 | |
Download: ML17018A104 (30) | |
Text
`
February 2, 2017 Mr. Matt J. Feyrer, Director General Electric-Hitachi Vallecitos Nuclear Center 6705 Vallecitos Road Sunol, CA 94586
SUBJECT:
EXAMINATION REPORT NO. 50-073/OL-17-01, GENERAL ELECTRIC-HITACHI VALLECITOS NUCLEAR CENTER
Dear Mr. Feyrer:
During the week of October 3, 2016, the U.S. Nuclear Regulatory Commission (NRC) administered an operator licensing examination at your General Electric-Hitachi Nuclear Test Reactor (GEH NTR). The examinations were conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed with those members of your staff identified in the enclosed report at the conclusion of the examination.
In accordance with Title 10 of the Code of Federal Regulations, Section 2.390, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. Should you have any questions concerning this examination, please contact Ms. Michele DeSouza at (301) 415-0747 or via internet e-mail Michele.DeSouza@nrc.gov.
Sincerely,
/RA/
Anthony J. Mendiola, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.50-073
Enclosures:
- 1. Examination Report No. 50-073/OL-17-01
- 2. Written Examination cc: w/o enclosures: See next page
February 2, 2017 Mr. Matt J. Feyrer, Director General Electric-Hitachi Vallecitos Nuclear Center 6705 Vallecitos Road Sunol, CA 94586
SUBJECT:
EXAMINATION REPORT NO. 50-073/OL-17-01, GENERAL ELECTRIC-HITACHI VALLECITOS NUCLEAR CENTER
Dear Mr. Feyrer:
During the week of October 3, 2016, the U.S. Nuclear Regulatory Commission (NRC) administered an operator licensing examination at your Nuclear Test Reactor. The examinations were conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed with those members of your staff identified in the enclosed report at the conclusion of the examination.
In accordance with Title 10 of the Code of Federal Regulations, Section 2.390, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. Should you have any questions concerning this examination, please contact Ms. Michele DeSouza at (301) 415-0747 or via internet e-mail Michele.DeSouza@nrc.gov.
Sincerely,
/RA/
Anthony J. Mendiola, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.50-073
Enclosure:
- 1. Examination Report No. 50-073/OL-17-01
- 2. Written Examination cc: w/o enclosures: See next page DISTRIBUTION w/ encls.:
PUBLIC AMendiola OFont AAdams DHardesty ADAMS ACCESSION #: ML17018A104 TEMPLATE #:NRR-079 OFFICE NRR/DPR/PROB:CE NRR/DPR PROB: RI NRR/DPR IOLB:OLA NRR/DPR PROB:BC NAME MDeSouza OFont ABaxter AMendiola DATE 01/06/2017 01/31/2017 01/18/2017 02/02/2017 OFFICIAL RECORD COPY
General Electric-Hitachi Vallecitos Nuclear Center Docket No.50-073 cc:
Mark Leik, Manager Regulatory Compliance GE Hitachi Nuclear Energy Vallecitos Nuclear Center 6705 Vallecitos Road Sunol, CA 94586 Daniel Thomas, Manager Nuclear Test Reactor GE Hitachi Nuclear Energy Vallecitos Nuclear Center 6705 Vallecitos Road Sunol, CA 94586 Scott Murray, Manager Facility Licensing GE Hitachi Nuclear Energy 3901 Castle Hayne Road Wilmington, NC 28401 Commissioner California Energy Commission 1516 Ninth Street, MS-34 Sacramento, CA 95814 California Department of Health ATTN: Chief Radiologic Health Branch P.O. Box 997414, MS 7610 Sacramento, CA 95899-7414 Test, Research and Training Reactor Newsletter P.O. Box 118300 University of Florida Gainesville, FL 32611-8300
U. S. NUCLEAR REGULATORY COMMISSION OPERATOR LICENSING INITIAL EXAMINATION REPORT REPORT NO.: 50-073/OL-17-01 FACILITY DOCKET NO.: 50-073 FACILITY LICENSE NO.: R-33 FACILITY: GEH NTR EXAMINATION DATES: October 3 - 6, 2016 SUBMITTED BY: _____/RA/___________________ _01/26/2017 Michele DeSouza, Chief Examiner Date
SUMMARY
During the week of October 3, 2016, the NRC administered an operator licensing examination to one Senior Reactor Operator (RO) candidate and one Reactor Operator candidate. The Senior Reactor Operator candidate failed Category B of the operating test. One Reactor Operator candidate failed Category A of the written examination and Category B of the operating test.
REPORT DETAILS
- 1. Examiner: Michele DeSouza, Chief Examiner, NRC
- 2. Results:
RO PASS/FAIL SRO PASS/FAIL TOTAL PASS/FAIL Written 0/1 1/0 1/1 Operating Tests 0/1 0/1 0/2 Overall 0/1 0/1 0/2
- 3. Exit Meeting:
Michele C. DeSouza, Chief Examiner, NRC Osvaldo Font, Inspector, NRC Thomas Caine, Former Director, GEH Vallecitos Nuclear Center Daniel Thomas, Director, GEH NTR Mark Leik, Manager, Environmental Health and Safety, Vallecitos Nuclear Center Per discussion with the facility, prior to administration of the examination, adjustments were accepted. Upon completion of the examination, the NRC Examiner met with facility staff representatives to discuss the results. At the conclusion of the meeting, the NRC examiner thanked the facility for their support in the administration of the examination.
Enclosure 1
U.S. NUCLEAR REGULATORY COMMISSION NON-POWER REACTOR LICENSE EXAMINATION FACILITY: GEH NTR REACTOR TYPE: TRIGA DATE ADMINISTERED: 10/04/2016 CANDIDATE: _______________________
INSTRUCTIONS TO CANDIDATE:
Answers are to be written on the Answer sheet provided. Attach all Answer sheets to the examination. Point values are indicated in parentheses for each question. A 70% in each category is required to pass the examination. Examinations will be picked up three (3) hours after the examination starts.
% OF CATEGORY % OF CANDIDATE'S CATEGORY VALUE TOTAL SCORE VALUE CATEGORY 20.00 33.3 A. REACTOR THEORY, THERMODYNAMICS AND FACILITY OPERATING CHARACTERISTICS 20.00 33.3 B. NORMAL AND EMERGENCY OPERATING PROCEDURES AND RADIOLOGICAL CONTROLS 20.00 33.3 C. FACILITY AND RADIATION MONITORING SYSTEMS 60.00 % TOTALS FINAL GRADE All work done on this examination is my own. I have neither given nor received aid.
Candidate's Signature Enclosure 2
Category A - Reactor Theory, Thermodynamics, & Facility Operating Characteristics ANSWER SHEET Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
A01 a b c d ___
A02 a b c d ___
A03 a ___ b ___ c ___ d ___ (0.25 each)
A04 a b c d ___
A05 a b c d ___
A06 a b c d ___
A07 a b c d ___
A08 a b c d ___
A09 a b c d ___
A10 a b c d ___
A11 a b c d ___
A12 a b c d ___
A13 a b c d ___
A14 a b c d ___
A15 a b c d ___
A16 a b c d ___
A17 a b c d ___
A18 a b c d ___
A19 a b c d ___
A20 a b c d ___
(***** END OF CATEGORY A *****)
Category B - Normal/Emergency Operating Procedures and Radiological Controls ANSWER SHEET Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
B01 a b c d ___
B02 a b c d ___
B03 a b c d ___
B04 a b c d ___
B05 a b c d ___
B06 a b c d ___
B07 a b c d ___
B08 a b c d ___
B09 a ____ b ____ c ____ d ____ (0.25 each)
B10 a b c d ___
B11 a b c d ___
B12 a b c d ___
B13 a b c d ___
B14 a b c d ___
B15 a b c d ___
B16 a b c d ___
B17 a b c d ___
B18 a ___ b ___ c ___ (0.33 each)
B19 a b c d ___
B20 a b c d ___
(***** END OF CATEGORY B *****)
Category C - Facility and Radiation Monitoring Systems ANSWER SHEET Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
C01 a ___ b ___ c ___ (0.33 each)
C02 a b c d ___
C03 a b c d ___
C04 a b c d ___
C05 a b c d ___
C06 a b c d ___
C07 a b c d ___
C08 a b c d ___
C09 a b c d ___
C10 a ___ b ___ c ___ d ___ (0.25 each)
C11 a b c d ___
C12 a b c d ___
C13 a b c d ___
C14 a b c d ___
C15 a b c d ___
C16 a b c d ___
C17 a b c d ___
C18 a b c d ___
C19 a b c d ___
C20 a b c d ___
(***** END OF CATEGORY C *****)
(********** END OF EXAMINATION **********)
NRC RULES AND GUIDELINES FOR LICENSE EXAMINATIONS During the administration of this examination the following rules apply:
- 1. Cheating on the examination means an automatic denial of your application and could result in more severe penalties.
- 2. After the examination has been completed, you must sign the statement on the cover sheet indicating that the work is your own and you have neither received nor given assistance in completing the examination. This must be done after you complete the examination.
- 3. Restroom trips are to be limited and only one candidate at a time may leave. You must avoid all contacts with anyone outside the examination room to avoid even the appearance or possibility of cheating.
- 4. Use black ink or dark pencil only to facilitate legible reproductions.
- 5. Print your name in the blank provided in the upper right-hand corner of the examination cover sheet and each Answer sheet.
- 6. Mark your Answers on the Answer sheet provided. USE ONLY THE PAPER PROVIDED AND DO NOT WRITE ON THE BACK SIDE OF THE PAGE.
- 7. The point value for each question is indicated in [brackets] after the question.
- 8. If the intent of a question is unclear, ask questions of the examiner only.
- 9. When turning in your examination, assemble the completed examination with examination questions, examination aids and Answer sheets. In addition turn in all scrap paper.
- 10. Ensure all information you wish to have evaluated as part of your Answer is on your Answer sheet. Scrap paper will be disposed of immediately following the examination.
- 11. To pass the examination you must achieve a grade of 70 percent or greater in each category.
- 12. There is a time limit of three (3) hours for completion of the examination.
EQUATION SHEET
( )2 eff = 0.1sec 1 Q&= m&cP T = m&H =UAT Pmax =
(2 )
t P = P0 e S S SCR = * =1x104 sec 1 K eff eff + &
SUR = 26 .06
( ) (
CR1 1 K eff1 = CR2 1 K eff 2 ) CR1 ( 1 ) = CR2 ( 2 )
(1 ) M=
1
= 2 CR P = P0 10SUR(t )
P= P0 1 K eff CR1 1 K eff1 1 K eff
- M= SDM = =
1 K eff 2 K eff
- 0.693 K eff 2 K eff1
+ T1 =
eff + & 2 K eff1 K eff 2 K eff 1
= DR = DR0 e t 2 DR1 d1 = DR2 d 2 2
K eff 6 Ci E (n) ( 2 )2 = (1 )2 DR =
R2 Peak2 Peak1 DR - Rem, Ci - curies, E - Mev, R - feet 1 Curie = 3.7 x 1010 dis/sec 1 kg = 2.21 lb 1 Horsepower = 2.54 x 103 BTU/hr 1 Mw = 3.41 x 106 BTU/hr 1 BTU = 778 ft-lb °F = 9/5 °C + 32 1 gal (H2O) 8 lb °C = 5/9 (°F - 32) cP = 1.0 BTU/hr/lb/°F cp = 1 cal/sec/gm/°C
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.01 [1.0 point]
What is eff?
- a. The fractional change in neutron population per generation
- b. The fraction of all fission neutrons that are born as delayed neutrons
- c. The time required for the reactor to change by power by a factor of e
- d. The fraction of all delayed neutrons that reach thermal energy QUESTION A.02 [1.0 point]
Which ONE of the following isotopes will absorb neutrons quickly when it interacts with neutrons?
- a. Hydrogen-1
- b. Carbon-14
- c. Boron-10
- d. Uranium-235 QUESTION A.03 [1.0 point, 0.25 each]
Match the following Neutron Interactions (each used only once)
- a. Fission 1. Neutron enters nucleus, forms a compound nucleus, then decays by gamma emission
- b. Radiative capture 2. Particle enters nucleus, forms a compound nucleus and is excited enough to eject a new particle with incident neutron remaining in nucleus
- c. Scattering 3. Nucleus absorbs neutron and splits into two similarly sized parts
- d. Particle ejection 4. Nucleus is struck by a neutron and emits a single neutron
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.04 [1.0 point]
Which ONE of the following is a correct statement of how delayed neutrons enhance the ability to control reactor power?
- a. Prompt neutrons can cause fissions in both U-235 and U-238 and delayed neutrons can only cause fissions in U-235
- b. Delayed neutrons are born at higher energy levels than prompt neutrons
- c. The average number of delayed neutrons produced per fission is higher than the average number of prompt neutrons
- d. Delayed neutrons increase the average neutron lifetime that allows a reactor to be controlled QUESTION A.05 [1.0 point]
The following shows part of a decay chain for the radioactive element Pa-234:
91Pa 234 92U 234 This decay chain is an example of _______ decay.
- a. Alpha
- b. Beta
- c. Gamma
- d. Neutron QUESTION A.06 [1.0 point]
Assume that the worths of the Shim rod is $3.50, Safety rod is $4.50, and Reg rod is $2.25.
The reactor is critical at 15 W after WITHDRAWING the following control rod worths: Shim
$2.20, Safety $3.40, and Reg $1.50. What is the CORE EXCESS?
- a. $2.85
- b. $3.15
- c. $5.50
- d. $7.10
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.07 [1.0 point]
Which ONE of the following is the MAJOR source of energy released during fission?
- a. Fission fragments
- b. Fission product decay
- c. Prompt gamma rays
- d. Fission neutrons (kinetic energy)
QUESTION A.08 [1.0 point]
Which one of the following statements describes the difference between differential rod worth (DRW) and integral rod worth (IRW) curves?
- a. DRW relates the time rate of reactivity change to rod position. IRW relates the total reactivity in the core to the time rate of reactivity change
- b. IRW relates the worth of the rod per increment of movement to rod position. DRW relates the total reactivity added by the rod to the rod position
- c. IRW is the slope of the DRW at a given rod position
- d. DRW relates the worth of the rod per increment of movement to rod position. IRW relates the total reactivity added by the rod to the rod position QUESTION A.09 [1.0 point]
Which ONE of the following best describes the difference between reflectors and moderators?
- a. Reflectors decrease thermal leakage while moderators decrease fast leakage
- b. Reflectors thermalize neutrons while moderators decrease core leakage
- c. Reflectors decrease core leakage while moderators thermalize neutrons
- d. Reflectors shield against neutrons while moderators decrease core leakage QUESTION A.10 [1.0 point]
What is the condition of the reactor when k = ?
- a. Subcritical
- b. Critical
- c. Super critical
- d. Prompt critical
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.11 [1.0 point]
A subcritical reactor, keff is increased from 0.914 to 0.965. Which ONE of the following is the amount of reactivity that was added to the core?
- a. 3.64%k/k
- b. 4.38%k/k
- c. 5.78%k/k
- d. 6.57%k/k QUESTION A.12 [1.0 point]
Which ONE of the following parameters is MOST significant in determining the differential rod worth of a control rod?
- a. Fuel temperature
- b. Flux shape
- c. Reactor power
- d. Rod speed QUESTION A.13 [1.0 point]
During the time following a reactor scram, reactor power decreases on an 80 second period, which corresponds to the half-life of the longest-lived delayed neutron precursors, which is approximately _________.
- a. 20 seconds
- b. 40 seconds
- c. 55 seconds
- d. 80 seconds QUESTION A.14 [1.0 point]
Which factors of the six factor formula are affected by an INCREASE in core temperature and how are they affected?
- a. Lf, p, f
- b. , Lf, Lt, p
- c. , Lf, Lt, p, , f
- d. , Lf, Lt, p, , f
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.15 [1.0 point]
The reactor is on a CONSTANT positive period. Which ONE of the following power changes will take the SHORTEST time to complete?
- a. From 100 kW to 150 kW
- b. From 10 kW to 20 kW
- c. From 10 W to 30 W
- d. From 1 W to 5 W QUESTION A.16 [1.0 point]
Which ONE of the following is the reason for an installed neutron source within the reactor core?
- a. Without it, a reactor startup is impossible as no neutrons would be available
- b. Power can be compensated for by adjusting the compensating voltage on the source range detector
- c. Could result in a very short period due to the reactor going critical before the neutron population is built up high enough to be read on nuclear instrumentation
- d. Would be very slow due to the long time to build up the neutron population from such a low level QUESTION A.17 [1.0 point]
How high will the reactor power get given the lowest of the reactor high power scrams set point is 110%, the scram delay time is 0.5 seconds, the reactor is operating at 100% power prior to the scram, and the reactor period is positive 20 second?
- a. 113%
- b. 115%
- c. 120%
- d. 220%
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics QUESTION A.18 [1.0 point]
Reactor is critical. What would be the corresponding keff when removing 0.05 k/k from its criticality?
- a. 0.9951
- b. 0.9524
- c. 0.9750
- d. 1.0526 QUESTION A.19 [1.0 point]
Given a source strength of 150 neutrons per second (N/sec) and a multiplication factor of 0.7, which ONE of the following is the expected stable neutron count rate?
- a. 150 N/sec
- b. 250 N/sec
- c. 400 N/sec
- d. 500 N/sec QUESTION A.20 [1.0 point]
Two common FISSION PRODUCTS that have especially large neutron cross sections and play a significant role in reactor physics are Xe-135 and _________.
- a. Nitrogen-16
- b. Argon-41
- c. Iodine-131
- d. Samarium-149
(***** END OF CATEGORY A *****)
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.01 [1.0 point]
Which ONE of the following conditions is a violation of General Electric Hitachi Nuclear Test Reactor Technical Specifications, reactor primary coolant water?
- a. Conductivity of the primary coolant water is 10umhos/cm
- b. Primary coolant temperature is 200oF during reactor operation
- c. Primary coolant flow is 20gpm while reactor power is 10 kW
- d. Primary coolant water pH is 5.4 QUESTION B.02 [1.0 point]
In accordance with Vallecitos Nuclear Center site emergency procedures, a fire that could prevent a safety system from performing its intended function, is an example of what type of classification?
- a. General area emergency
- b. Site area emergency
- c. Alert
- d. Notification of Unusual event QUESTION B.03 [1.0 point]
Which ONE of the following is the definition for Annual Limit on Intake?
- a. The concentration of a radionuclide in air which, if inhaled by an adult worker for a year, results in a total effective dose equivalent of 100 mrem
- b. The effluent concentration of a radionuclide in air which, if inhaled continuously over a year, would result in a total effective dose equivalent of 50 mrem for noble gases
- c. 10CFR20 derived limit, based on a Committed Effective Dose Equivalent of 5 rem whole body or 50 rems to any individual organ, for the amount of radioactive material inhaled or ingested in a year by an adult worker
- d. Projected dose commitment to individuals that warrant protective action following a release of radioactive material
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.04 [1.0 point]
Which ONE of the following is NOT a responsibility of the SRO and RO?
- a. Review and audit of safety aspects of reactor facility operations
- b. Insertion and removal of experiments
- c. Participation in requalification program
- d. Preparation of logs and records of reactor operations QUESTION B.05 [1.0 point]
Per GEH NTR Technical Specifications, what is the MINIMUM level of management who may direct any experiment or facility change with a reactivity worth greater than one dollar?
- a. Reactor Director
- b. Operations Supervisor
- c. SRO at the facility
- d. SRO on call QUESTION B.06 [1.0 point]
Which ONE of the following situations requires an immediate shutdown?
- a. Unexplained reactivity change of $0.05
- b. Reactivity change greater than $0.25
- c. Excess reactivity is greater than $0.76
- d. An instrument indicating an oscillation of more than 10% peak to peak QUESTION B.07 [1.0 point]
How long will it take a 50 Curie source, with a half-life of 5.26 years, to decay to 2 Curie?
- a. 10.5 Years
- b. 15.5 Years
- c. 24.5 Years
- d. 35.5 Years
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.08 [1.0 point]
Which ONE of the following is NOT required to prepare a Radiation Work Permit (RWP)?
- a. Start and expiration date
- b. ALARA plan
- c. NRC permission
- d. Description of work and instruction for radiological work QUESTION B.09 [1.0 point, 0.25 each]
Identify each of the following surveillances as a channel check (CHECK), a channel test (TEST),
or a channel calibration (CAL). Write the correct answer on your answer sheet next to the space given for each example listed below
- a. During performance of the daily checklist, you compare the prestart readings of the radiation area monitors to the previous day readings
- b. During performance of the daily checklist, you press the scram button to verify a scram on the safety system channel
- c. Adjustment of the wide range linear channel in accordance with recent data collected during a reactor power calibration
- d. You expose a 2 mCi check source to the stack particulate monitor detector to verify that it alarms at 10,000 cpm QUESTION B.10 [1.0 point]
10 CFR 20 limits the annual occupational exposure to the WHOLE BODY of an individual to:
- a. 5 rem
- b. 15 rem
- c. 50 rem
- d. 100 rem QUESTION B.11 [1.0 point]
Under steady-state conditions, the maximum power level shall be no greater than 190 kW.
This is an example of:
- a. Safety Limit
- b. Limiting Safety System Setting
- c. Limiting Conditions for Operation
- d. Safety Operational Limit
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.12 [1.0 point]
Calculate an individuals total whole body dose given the individual received the following doses: 5 mrad of alpha, 10 mrad of gamma, and 10mrad of neutron (unknown energy)
- a. 190 mrem
- b. 200 mrem
- c. 210 mrem
- d. 220 mrem QUESTION B.13 [1.0 point]
What is your dose rate at 9 feet away from the source, if you are receiving 250 mR/hr at 3 feet away from the source?
- a. 24 mR/hr
- b. 28 mR/hr
- c. 32 mR/hr
- d. 36 mR/hr QUESTION B.14 [1.0 point]
Based on the GEH NTR Requalification Plan, each operator must perform the functions of a licensed operator to maintain an active operators license a MINIMUM of __________.
- a. 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> per year
- b. 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> per quarter
- c. 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> per month
- d. 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> per quarter QUESTION B. 15 [1.0 point]
In accordance with procedures which ONE of the following individuals receives, reviews, and transmits reportable incidents to the Nuclear Regulatory Commission?
- a. Reactor Operator
- b. Senior Reactor Operator
- c. Manager, Nuclear Test Reactor
- d. Manager, Regulatory Compliance
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.16 [1.0 point]
10CFR55 states in order to maintain your active operator licensure you must receive a medical examination conducted in accordance with ANSI 15.4. What is the medical examination maximum required frequency?
- a. One year
- b. Two years
- c. Four years
- d. Six years QUESTION B.17 [1.0 point]
Radiation from an unshielded Co-60 source is 600 mrem/hr. What thickness of lead shielding will be needed to lower the radiation level to 5 mrem/hr? Assume: half-value layer of lead is 6.5mm
- a. 27 mm
- b. 34 mm
- c. 39 mm
- d. 45 mm QUESTION B.18 [1.0 point, 0.33 each]
Match the appropriate emergency classification in Column A with the stack gas or particulate monitor release reading (radioactive effluent concentration in excess of alarm set point (if applicable)) in Column B.
Column A Column B
- a. Notification of Unusual Event 1. 1750 times alarm set point for 30 minutes
- b. Alert 2. 3000 times alarm set point for 10 minutes
- c. Site Area Emergency 3. 500 times alarm set point for 15 minutes QUESTION B.19 [1.0 point]
Which ONE of the following is the radiation dose limit for the public in an unrestricted area?
- a. No limit
- b. 2 rem in a year
- c. 2 rem in any one hour
- d. 2 mrem in any one hour
Category B: Normal/Emergency Operating Procedures and Radiological Controls QUESTION B.20 [1.0 point]
A two curie source emits a 2MeV gamma 100% of the time. The source will be placed in the reactor storage building. How far from the source should a high radiation area sign be posted?
- a. Not required
- b. 10.5 feet
- c. 12.5 feet
- d. 15.5 feet
(***** End of Category B *****)
Category C: Facility and Radiation Monitoring Systems QUESTION C.01 [1.0 point, 0.33 each]
Match the facility radiation detector in Column A with the type of radiological problem it detects in Column B.
Column A Column B
- a. RAM 1. Gases Only
- b. Stack Monitor 2. Radiation Level
- c. CAM 3. Particulates Only
- 4. Gases and Particulates QUESTION C.02 [1.0 point]
What is the primary coolant water flow path starting at the reactor outlet?
- a. Flow orifice, hold-up tank, primary pump, heat exchanger, reactor inlet
- b. Flow orifice, heat exchanger, air trap, primary pump, reactor inlet
- c. Primary pump, heat exchanger, flow orifice, air trap, reactor inlet
- d. Hold-up tank, air trap, flow orifice, primary pump, reactor inlet QUESTION C.03 [1.0 point]
Which ONE of the following is the GEH NTR definition utilized for a High Radiation Area?
- a. Reactor cell and the south cell
- b. Dose in excess of 5 mrem in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 30 cm
- c. Dose in excess of 100 mrem in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 30 cm
- d. Inner fenced area at the Vallecitos Nuclear Center QUESTION C.04 [1.0 point]
Which ONE of the following is an accurate description of how thermal power is determined?
- a. Measurement of the rise and fall of the core temperature averaged over the previous year
- b. Overall measurements of coolant temperatures through the primary and secondary
- c. Heat balance measurement using coolant flow through the core and differential temperature across the core
- d. Ambient temperature measurements throughout the year and measured against the core configured temperature differentials
Category C: Facility and Radiation Monitoring Systems QUESTION C.05 [1.0 point]
GEH NTR Technical Specifications requires fuel elements be stored in a safe array where the keff is less than _______.
- a. 0.6
- b. 0.7
- c. 0.8
- d. 0.9 QUESTION C.06 [1.0 point]
The control rod poison section is contained in which ONE of the following materials?
- a. Aluminum
- b. Stainless steel
- c. Cadmium
- d. Graphite QUESTION C.07 [1.0 point]
Which ONE of the following will cause a HIGH conductivity reading at the inlet of the demineralizer?
- a. Primary coolant water temperature low
- b. High reactor water pump flow
- c. Reactor water system pressure greater than secondary water pressure
- d. Failure of fuel elements QUESTION C.08 [1.0 point]
Which ONE of the following SCRAM indications is NOT associated with the log N channel?
- a. High reactor power
- b. Short reactor period
- c. Loss of positive high voltage to ion chambers
- d. Amplifier mode switch in operate
Category C: Facility and Radiation Monitoring Systems QUESTION C.09 [1.0 point]
Which ONE of the following conditions will activate the low differential pressure safety system?
- a. Stack to CAM pressure increase
- b. Primary to secondary pressure drop
- c. Secondary to primary pressure increase
- d. Reactor cell pressure drop QUESTION C.10 [1.0 point, 0.25 each]
Match the control rod drive mechanism from Column A with the correct function in Column B.
Column A Column B
- a. Drive out 1. Interrupts voltage and deenergizes safety rod electromagnets
- b. Drive in 2. Provide indication of rod stroke fully out
- c. Safety rod in 3. Provide indication of rod stroke fully inserted
- d. Separation switch 4. Works with circuit to provide rod fully inserted position QUESTION C.11 [1.0 point]
What indication would result from a heat exchanger leak?
- a. Reduction of primary coolant flow
- b. Reduction of secondary coolant flow
- c. High level alarm in the fuel loading tank
- d. High level alarm in the core tank QUESTION C.12 [1.0 point]
Which ONE of the following is NOT a reason for performance of control rod calibration?
- a. After a change in reactor core configuration
- b. Reactor control systems are altered
- c. Fresh fuel has been added to the reactor core
- d. Shutdown margin increase of $0.20
Category C: Facility and Radiation Monitoring Systems QUESTION C.13 [1.0 point]
Which ONE of the following correctly describes the operation of a thermocouple?
- a. Junction of two dissimilar metals, generating a potential (voltage proportional to temperature changes
- b. Bi-metalic strip that winds or unwinds dependent on the different thermal expansion constants for the two metals, moves a lever proportional to the temperature changes
- c. Precision wound resistor, inside a bridge device, resistance varies proportionally to the temperature changes
- d. Liquid filled container, expands or contracts proportional to temperature changes, external wires report readings to a lever QUESTION C.14 [1.0 point]
When the reactor is operating above a power level of ______ no experimental objects will be placed in the core tank.
- a. 0.1 W
- b. 50 W
- c. 100 W
- d. 0.1 kW QUESTION C.15 [1.0 point]
Which region of the pulse size versus applied voltage characteristic curve do the power channel detectors operate?
- a. Proportional
- b. Ion Chamber
- d. Limited Proportional QUESTION C.16 [1.0 point]
Per GEH NTR Primary Coolant System SOP 1-1, what material is the plug that is placed in the loading chute (when not in use)?
- a. Aluminum clad graphite
- b. Stainless steel clad graphite
- d. Lead lined air filled
Category C: Facility and Radiation Monitoring Systems QUESTION C.17 [1.0 point]
When a downscale alarm is indicated, it is wired to a _________ and which of the following will occur?
- a. Loss of power to all rods, and a SCRAM will occur
- b. Low power annunciator, and control and safety rods automatically withdraw to compensate for the power demand
- c. Rod block annunciator, and control and safety rods cannot be withdrawn
- d. Control rod annunciator, and control rods cannot be withdrawn but safety rods can be withdrawn to compensate for the power demand difference QUESTION C.18 [1.0 point]
Which ONE of the following conditions will NOT cause the operating reactor to automatically scram?
- a. Reactor period = 6 seconds
- b. Loss of high voltage to two of the power channels
- c. Primary coolant temperature = 220oF
- d. Low power indication on linear power channel QUESTION C.19 [1.0 point]
Which ONE of the following is the neutron absorber in the GEH NTR reactor control rods?
- a. Graphite
- b. Zirconium hydride
- c. Boron carbide
- d. Aluminum oxide
Category C: Facility and Radiation Monitoring Systems QUESTION C.20 [1.0 point]
Where is the majority of the facilitys Ar-41 produced?
- a. Horizontal facility
- b. Vertical facility
- c. Fuel loading chute
- d. Thermal column
(***** END OF CATEGORY C *****)
((***** END OF EXAM *****))
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics A.01 Answer: b
Reference:
DOE Fundamentals Handbook Nuclear Physics and Reactor Theory, Volume 2, Module 2 A.02 Answer: c
Reference:
Burn, Introduction to Nuclear Reactor Operations, Section 2.5.1, Pages 2-38-43 A.03 Answer: a3 b1 c4 d2
Reference:
DOE Fundamentals Handbook Nuclear Physics and Reactor Theory, Volume 1, Module 1, Page 43-46 A.04 Answer: d
Reference:
Burn, Introduction to Nuclear Reactor Operations, Section 3.3.2, Page 3-7 A.05 Answer: b
Reference:
Chart of the Nuclides A.06 Answer: b
Reference:
Total Worth = $3.50+$4.50+$2.25=$10.25 Reactivity at 15 W=$2.20+$3.40+$1.50 = $7.10 Core Excess = Total Worth - Reactivity@15 W = $10.25-$7.10= $3.15 A.07 Answer: b
Reference:
Burn, Introduction to Nuclear Reactor Operations, Table 3.2, Page 3-5 A.08 Answer: d
Reference:
DOE Fundamentals Handbook Nuclear Physics and Reactor Theory, Volume 2, Module 1 A.09 Answer: c
Reference:
Burn, Introduction to Nuclear Reactor Operations, Section 5.4 A.10 Answer: c
Reference:
LaMarsh, Introduction to Nuclear Engineering, Page 340-341 (1-B)k=1 manipulated reads k=1/(1-B)
A.11 Answer: c
Reference:
Burn, Introduction to Nuclear Reactor Operations, Section 3.3.4, Page 3-20&21
=(keff2-keff1)/(keff1*keff2) = (0.965-0.914)/(0.965*0.914) = 0.0578k/k=5.78%k/k
Category A: Reactor Theory, Thermodynamics, and Facility Operating Characteristics A.12 Answer: b
Reference:
Burn, Introduction to Nuclear Reactor Operations, Section 7.2 A.13 Answer: c
Reference:
LaMarsh, Introduction to Nuclear Engineering, Page 88 Group 1 is longest lived neutron precursor for thermal fission in U-235 with a half-life of 55.72 seconds A.14 Answer: a
Reference:
DOE Fundamentals Handbook Nuclear Physics and Reactor Theory, Volume 2, Module 1 A.15 Answer: a
Reference:
P=Poet/Tt=T*ln(P/Po) assume constant period=1 The smallest ratio of P/Po is the shortest time to complete A.16 Answer: c
Reference:
Burn, Introduction to Nuclear Reactor Operations, Section 5.2.2, Pages 5 5-4 A.17 Answer: a
Reference:
P/Po = 110%, T = 20 seconds, t = 0.5, P/Po = 110 e^0.5/20 = 112.78%
A.18 Answer: b
Reference:
=(k-1)/k-0.051=k-(-0.05k)=k(1+0.05)k=1/1.05 =0.9524 A.19 Answer: d
Reference:
CR=S/(1-k)150/(1-0.7) = 500 N/sec A.20 Answer: d
Reference:
Burn, Introduction to Nuclear Reactor Operations, Section 8.1, Page 8-1
Category B: Normal/Emergency Operating Procedures and Radiological Controls B.1 Answer: b
Reference:
GEH NTR TS 3.3.3.3, 3.3.4, and Table 3-1 B.2 Answer: c
Reference:
GEH NTR, Site Emergency Procedures C-5, 4.2 B.3 Answer: c
Reference:
10CFR20.1003 B.4 Answer: a
Reference:
GEH NTR TS 6.1.4, 6.2.1, and 6.2.3 B.5 Answer: c
Reference:
GEH NTR TS 6.1.3.2 B.6 Answer: c
Reference:
Reference:
T A = A*e -t 2Ci = 50Ci* e -(t)
Ln(2/50) = -ln2/5.27 yr*(t) --> -3.2189/-0.1315 solve for t: 24.47 years B.8 Answer: c
Reference:
GEH NTR Radiological Safety SOP 7.9 B.9 Answer: a (check), b (test), c (cal) , d (test)
Reference:
GEH NTR TS definitions B.10 Answer: a
Reference:
10 CFR 20.1201 B.11 Answer: a
Reference:
GEH NTR TS 2.1.4 B.12 Answer: c
Reference:
5mrad Alpha x 20=100mrem, 10mrad Gamma x 1=10mrem, 10mrad neutron x 10 = 100mrem 100mrem+10mrem+100mrem= 210mrem
Category B: Normal/Emergency Operating Procedures and Radiological Controls B.13 Answer: b
Reference:
I1D12=I2D22 250mR/hr@(3ft)2=I2@(9ft)2 28mR/hr B.14 Answer: d
Reference:
10CFR55.59, GEH NTR Administrative Procedures, Chapter 9.0, Procedure 9.13, Section 9.1 B.15 Answer: d
Reference:
GEH NTR Administrative Procedures, Chapter 9.0, Procedure 9.11, Section 4.1 B.16 Answer: b
Reference:
10CFR55; ANSI 15.4, 1988 B.17 Answer: d
Reference:
DR=DRoe^-ux, HVL =6.5mm 1=2e^-u*6.5 so u=0.10664, 5mrem/hr = 600mrem/hr e^-0.10664*X, X = 44.89mm B.18 Answer: a (3), b (1), c (2)
Reference:
GEH NTR Site Emergency Procedure E-5, Table 1 B.19 Answer: d
Reference:
B.20 Answer: d
Reference:
I=6CEn=R/hr@ft.2Ci x 2Mev x 100% = 24 R/hr@ (1ft)2 =
24 R/hr = 0.1 R/hr@ D2 = 240 R/hr = 15.5 ft.
Category C: Facility and Radiation Monitoring Systems C.01 Answer: a (2), b (4), c (3)
Reference:
GEH NTR SAR Section 11.1.4, and Radiation Protection Procedures 10, Radiation Safety Procedure 7.0, Remote Area Monitor 7.2, Section 3.0, and Continuous Air Monitor 7.12, Section 3.0 C.02 Answer: b
Reference:
GEH NTR SAR 5-2 C.03 Answer: c
Reference:
GEH NTR Radiation Protection Procedure 10, Radiological Safety 7.0, Radiation Zone Classification 7.7 C.04 Answer: c
Reference:
GEH NTR SAR 7.3.3 C.05 Answer: d
Reference:
Reference:
GEH NTR SAR 4.2.2, page 4-8 C.07 Answer: d
Reference:
Standard NRC question C.08 Answer: d
Reference:
GEH NTR SAR Table 7-1 C.09 Answer: d
Reference:
GEH NTR SAR 3.5 C.10 Answer: a (2), b (3), c (4), d (1)
Reference:
GEH NTR SAR 4.2.2(1), (2), and (4)
C.11 Answer: c
Reference:
GEH NTR System Operating Procedures 13, Reactor Coolant Systems Chapter 1.0, Secondary Cooling System Procedure 1.5, Section 7.2 C.12 Answer: d
Reference:
GEH NTR System Operating Procedures 13.0, Reactor Control 3.0, Control Rod Calibrations 3.7
Category C: Facility and Radiation Monitoring Systems C.13 Answer: a
Reference:
GEH NTR Previous Exam 2010 C.14 Answer: d
Reference:
GEH NTR SAR 10.3, A, 4 C.15 Answer: b
Reference:
GEH NTR System Operating Procedures 13, Reactor Instrumentation 2.0, Startup Channel 2.2, Section 1.0 and NRC standard question C.16 Answer: a
Reference:
GEH NTR System Operating Procedures 13, Reactor Coolant Systems 1.0, Primary Coolant Systems 1.1, Section 3.6 C.17 Answer: c
Reference:
GEH NTR System Operating Procedures 13, Reactor Instrumentation 2.0, Pico-ammeter Channels 2.4, Section 3.5.1 C.18 Answer: d
Reference:
GEH NTR TS Table 3-1 & 3-2 C.19 Answer: c
Reference:
GEH NTR SAR 4.2.2 C.20 Answer: d