M230039 March 24, 2023 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555-001
Subject:
GEH Annual Shutdown Reactor Reports for the Year 2022
Reference:
License DPR-1, Docket 50-18 (VBWR), License DR-10, Docket 50-183 (EVESR), License TR-1, Docket 50-70 (GETR)
Enclosed are the 2023 Annual Reports for the deactivated Reactors (Vallecitos Boiling Water Reactor (VBWR), ESADA-Vallecitos Experimental Superheat Reactor (EVESR),
and the General Electric Test Reactor (GETR)} located at the GE Hitachi, Vallecitos Nuclear Center near Sunol, California.
If there are any questions or additional information required, please contact me at the number above.
Sincerely, Charles Pedley, Site Manager Vallecitos Nuclear Center
Enclosures:
VBWR Annual Report No. 58 EVESR Annual Report No. 55 GETR Annual Report No. 64 cc: NRC Region IV Administrator J. Parrott, NRC NMSS CP 23-006
GEHitachiNuclearEnergy
CharlesPedley
SiteManager,
VallecitosNuclearCenter
6705VallecitosRd
Sunol,CA94586
USA
T9255238101
Charles.Pedley@ge.com
CHARLES PEDLEY Digitally signed by CHARLES PEDLEY DN: cn=CHARLES PEDLEY c=US l=7249af3244cf2daca5eb6a8620187dbce5b61cd7 o=MyApps e=223062202@ge.com Reason: I am approving this document Location:
Date: 2023-03-23 10:37-07:00 HITACHI
Enclosures
VBWRAnnualReportNo.58
EVESRAnnualReportNo.55
GETRAnnualReportNo.64
GEHitachiNuclearEnergy
VallecitosNuclearCenter
Sunol,California
VALLECITOSBOILINGWATERREACTOR
(DEACTIVATED)
ANNUALREPORTNO.58
FORTHEYEAR2022
LICENSEDPR1
DOCKET5018
MARCH2023
HITACHI
VBWRAnnualReportNo.58
Page1of2 VallecitosBoilingWaterReactor
(Deactivated)
AnnualReportNo.58
GEHitachiNuclearEnergyhasmaintainedtheVallecitosBoilingWaterReactor(VBWR)ina
deactivatedstatusundertheauthorityofAmendmentNo.21toLicenseDPR1,Docket5018,
issuedOct22,2007.Inthisannualreport,asummaryofthestatusofthefacilityfortheperiod
ofJanuary1,2022,toDecember31,2022,ispresented,asrequiredbyparagraph5.d.2ofthe
license.
1.0
SUMMARY
Allreactorsystemshavebeenremovedfromthecontainmentexceptforthereactorvessel.
ThewaterfromthevesselwasremovedandtransferredtotheWasteEvaporatorPlant(WEP)
onJanuaryandNovember2022usingChangeAuthorizationCA202202,VBWRVesselEntry,
WaterRemovalandInspection/Survey,approvedon1/20/2022.
TheladderthatleadstothebasementwasreplacedwithstairsusingChangeAuthorization
202203,StairInstallationinVBWRLowerLevel,approvedonJune6,2022.
AsbestosandLeadabatementworkwascompletedincontainmentonOctoberandNovember
2022,usingCA202204,AsbestosandLeadabatement,approvedonJune29,2022.
Structuralconditionsandradiationandcontaminationlevelsremainatacceptablelevels.
Environmentaldataismaintainedonsiteandavailableforreview.
2.0STATUSOFFACILITY
Inaccordancewithwrittenprocedures,theFacilityManagercontrolsaccesstothecontainment
buildingandgeneralsystems.Thefacilitycontinuestobeindeactivatedstatusinsafestorage
condition.
3.0ROUTINEPATROLS
Thefacilitywasinspectedweekly,quarterly,andannuallyinaccordancewithwrittenstation
procedures.
Patrolsidentifiedthefollowing:
x UnchangedEfflorescenceonthebasementwallsandfloor.
x UnchangedSpallingofconcrete,corrosionstainsandrebarcorrosionontheBasement
PumpFoundationpedestal.
x UnchangedSeepageofwaterintothebasementborelocation.
VBWRAnnualReportNo.58
Page2of2
Theseconditionshavebeenevaluated,posenothreattostructuralintegrity,andarebeing
monitored.Thestructuralconditionofthefacilityisbeingactivelymonitoredandisstructurally
soundtoensuremaximumprotectionforpublichealthandsafety.
4.0RADIATIONANDCONTAMINATION
Completeradiationandcontaminationsurveysofthefacilityindicatethatlevelsremainlow.
Resultsofthesurveysarepresentedinattachment1.Airsamplingresultsarepresentedin
attachment2.Theradiation/contaminationlevelslistedarerepresentativebutnotnecessarily
maximumvalues.
AnalyticalresultsofgroundwatersamplesareavailableintheAnnualEnvironmentalReport
submittedonMarch2,2023.
5.0ACTIVITIES
Inspectionoftheinstalledgaugesshowednopropagationofconcretecracking.
Therewerenopreventiveorcorrectivemaintenanceactivitiesperformedhavingsafety
significanceduringthereportingperiod.
6.0ORGANIZATION
TheSiteManagerisC.Pedley.TheVBWRFacilityManagerisJ.G.Ayala.TheManager,
RegulatoryComplianceandEHSremainsJ.Smyly.
7.0CONCLUSION
GEHitachiNuclearEnergyconcludesthatthedeactivatedVBWRisbeingmaintainedinasafe
shutdowncondition.Theinspections,accesscontrol,andadministrativelycontrolledactivities
ensuremaximumprotectionforthepublichealthandsafety.Theprocedureswillbecontinued
tomaintainthishighlevelofprotection.
GEHitachiNuclearEnergy
VallecitosOperations
C.Pedley,ManagerVallecitosNuclearCenter
CHARLES PEDLEY Digitally signed by CHARLES PEDLEY DN: cn=CHARLES PEDLEY c=US l=7249af3244cf2daca5eb6a8620187dbce5 b61cd7 o=MyApps e=223062202@ge.com Reason: I am approving this document Location:
Date: 2023-03-23 10:38-07:00
VBWRANNUALSURVEY
VBWRSurveys
Contamination
DoseRates
SurveyID
RS2022010072
RS2022010073
D142
SurveyDate(s)
5/26/2022
12/07/2022
Surveyor
A.Flk
S.Peterson
J.Hatfield
M.Arnerich(signatureonoriginal)
Instrument
Ludlum2929
RadEye
InstrumentS/N
110575
33155
33155
CalibrationDueDate
9/15/2022
1/18/2023
7/14/2023
I-
ATTACHMENT1
0.048 VBWR MAIN FLOOR 0.094 MACHINERY HATCH 0.032
@) Q)
- EAM~
GENERA~OR
\
HATCH
~
0.033 Survey No.
0-142 Date:
12/07 /22 Surveyor(s)
Name & Signature on Original Document Smear Data taken 5/26/22 (see RSR2022-01-0072)
Page 1 of 2 0.050 0
0 Q.ll.22.
ap Legend Smear Location (100cm 2)
Contact Dose Rate in mR/hr All field dose rates in mR/hr
SLANTED W/\ll VBWR BASEMENT AREA 0
0.123 G
- 0. 313 SLANTED WALL 0
0 Survey No.
D-142 Date:
12/07 /22 Surveyor(s)
Name & Signature on Original Document Smear Data taken 5/ 26/22 (see RSR2022-01-0073)
Page 2 of 2 Map Legend Smear Location (100cm 2)
Contact Dose Rate in mR/hr All fi eld dose rates in mR{hr
VBWR Contamination Results IIMdm' laell remnll DIiie VBWR BSMT 1
<MDA
< MDA RSR2022-01-0073 5/26/2022 VBWR BSMT 2
570
< MDA RSR2022-01-0073 5/26/2022 VBWR BSMT 3
1406
<MDA RSR2022-01-0073 5/26/2022 VBWR BSMT 4
6129
< MDA RSR2022-01-0073 5/26/2022 VBWR BSMT 5
<MDA
< MDA RSR2022-01-0073 5/26/2022 VBWR BSMT 6
<MDA
< MDA RSR2022-01-0073 5/26/2022 VBWR Main 7
<MDA
< MDA RSR2022-01-0072 5/26/2022 VBWR Main 8
<MDA
< MDA RSR2022-01-0072 5/26/2022 VBWR Main 9
<MDA
< MDA RSR2022-01-0072 5/26/2022 VBWR Main 10
<MDA
< MDA RSR2022-01-0072 5/26/2022 VBWR Main 11
<MDA
< MDA RSR2022-01-0072 5/26/2022 VBWR Main 12
<MDA
< MDA RSR2022-0l-0072 5/26/2022 VBWR Main 13
<MDA
< MDA RSR2022-01-0072 5/26/2022
Air Sample Data for VNC Reactor Annual Inspection At Sample Time After Radon Decay After Radon Decay Reactor Location Date Alpha (uCi/ml) Beta (uCi/ml) Alpha (uCi/ml) Beta (uCi/ml)
Alpha (DAC)
Beta (DAC)
Main Floor 8/25/2022 8.51E-10 2.15E-09 l.37E-14 8.64E-13 0.005 0.000 VBWR Basement 9/21/2022 4.78E-10 l.58E-09 3.21E-14 3.07E-12 0.011 0.002 Fuel Pool 9/21/2022 3.22E-10 l.17E-09 7.78E-14 l.37E-12 0.026 0.001 Main Floor 11/29/2022 2.93E-09 8.88E-09 l.69E-13 2.64E-12 0.056 0.001 EVESR Basement 11/29/2022 4.21E-09 l.12E-08 0.00E+00 5.94E-12 0.000 0.003 519' Level 11/29/2022 3.60E-09 l.05E-08 7.78E-14 6.95E-12 0.026 0.003 Main Floor 11/15/2022 l.53E-10 4.23E-10 2.36E-14 l.35E-12 0.008 0.001 GETR Basement 11/15/2022 l.95E-10 5.44E-10 0.00E+00 l.12E-12 0.000 0.001 Third Floor 11/15/2022 2.16E-10 5.84E-10 l.14E-13 7.65E-13 0.Q38 0.000
GEHitachi
GEHitachiNuclearEnergy
Vallecitos
NuclearCenter
VallecitosNuclearCenter
Sunol,California
ESADAVALLECITOSEXPERIMENTAL
SUPERHEATREACTOR
(DEACTIVATED)
ANNUALREPORTNO.55
FORTHEYEAR2022
LICENSEDR10
DOCKET50183
MARCH2023
HITACHI
EVESRAnnualReportNo.55
Page1of2 ESADAVallecitosExperimentalSuperheatReactor
(Deactivated)
ANNUALREPORTNO.55
GEHitachiNuclearEnergy(GEH)hasmaintainedtheESADAVallecitosExperimentalSuperheat
Reactor(EVESR)inadeactivatedstatusundertheauthorityofAmendmentNo.7toLicenseDR 10,Docket50183,issuedDecember1,2008.Inthisannualreport,asummaryofthestatusof
thefacilityfortheperiodofJanuary1,2022,toDecember31,2022,ispresented,asrequiredby
Amendment7,AppendixA,TechnicalSpecifications,sectionC.1.
1.0
SUMMARY
Entryintothecontainmentbuildingwasmadeforroutineradiationsurveys,quarterlypatrols,
annualstructuralinspections,andageneralexaminationofconditionsthroughoutthebuilding.
Inaccordancewithwrittenprocedures,theFacilityManagercontrolsaccesstothecontainment
building.
Structuralconditionsandradiationandcontaminationlevelsremainatacceptablelevels.
Environmentaldataismaintainedonsiteandavailableforreview.
2.0STATUSOFFACILITY
Inaccordancewithwrittenprocedures,theFacilityManagercontrolsaccesstothecontainment
buildingandgeneralsystems.Thefacilitycontinuestobeindeactivatedstatus.Theplugstothe
reactorvessel,headstorageshield,andthewoodencoveroverthefuelstoragepoolremainin
place.
3.0ROUTINEPATROLS
Thefacilitywasinspectedweekly,quarterly,andannuallyinaccordancewithwrittenstation
procedures.
Threeissueswereidentifiedduringtheannualinspection:
- 1. Loose,falleninsulationwasfoundaroundtheperimeterofthemainfloorofEVESR.The
insulationisnotastructuralcomponentanddidnotcontainasbestos.
- 2. Corrosionwasidentifiedontheexposedrebarfloortieinextensionsthatarevisibleat
multiplelevelsofthefacility.Theseextensionsarenotstructuralcomponents.
- 3. Minimalefflorescencewasidentifiedatafewlocations.Thisconditionwasevaluatedand
doesnotposeastructuralissue.
EVESRAnnualReportNo.55
Page2of2 Thestructuralconditionofthefacilityremainsactivelymonitored,stableandstructurallysound
toensuremaximumprotectionforpublichealthandsafety.
4.0RADIATIONANDCONTAMINATION
Completeradiationandcontaminationsurveysofthefacilityindicatethatlevelsremainlow.
Resultsofthesurveysarepresentedinattachment1.Airsamplingresultsarepresentedin
attachment2.Theradiation/contaminationlevelslistedarerepresentativebutnotnecessarily
maximumvalues.
AnalyticalresultsofgroundwatersamplesareavailableintheAnnualEnvironmentalReport
submittedonMarch2,2023.
5.0ACTIVITIES
Routinepatrolsandinspectionswereconductedduringthisreportperiod.
Therewerenopreventiveorcorrectivemaintenanceactivitiesperformedhavingsafety
significanceduringthereportingperiod.
6.0ORGANIZATION
TheSiteManagerisC.Pedley.TheEVESRFacilityManagerisJ.G.Ayala.TheManager,
RegulatoryComplianceandEHSremainsJ.Smyly.
7.0CONCLUSION
GEHitachiNuclearEnergyconcludesthatthedeactivatedESADAVallecitosExperimental
SuperheatReactorisbeingmaintainedinasafeshutdowncondition.Theinspections,access
control,andadministrativelycontrolledactivitiesensuremaximumprotectionforthepublic
healthandsafety.Theprocedureswillbecontinuedtomaintainthishighlevelofprotection.
GEHitachiNuclearEnergy
VallecitosOperations
C.Pedley,ManagerVallecitosNuclearCenter
CHARLES PEDLEY Digitally signed by CHARLES PEDLEY DN: cn=CHARLES PEDLEY c=US l=7249af3244cf2daca5eb6a8620187dbce5b6 1cd7 o=MyApps e=223062202@ge.com Reason: I am approving this document Location:
Date: 2023-03-23 10:39-07:00
EVESRANNUALSURVEY
EVESRSurveys
Contamination
DoseRates
SurveyID
RS2022010061
RS2022010062
RS2022010064
RS2022010065
RS2022010066
D144
SurveyDate(s)
5/19/20225/25/2022
12/12/2022
Surveyor
T.Lopez(signatureonoriginals)
M.Arnerich(signatureonoriginal)
Instrument
Ludlum2929
RadEye
InstrumentS/N
110575
33155
33155
CalibrationDueDate
9/15/2022
1/18/2023
7/14/2023
--1
ESCAPE HATCH Survey No.
D-144 Date:
12/12/22 Surveyor(s)
EVESR 549' LEVEL Name & Signature on Original Document Smear Data taken 5/19/22 (see RSR2022-01-0065) 28 0.057 0.012 EQUIPMENT HATCH 0
Page 1 of6 0.029 0.016 0.011 Map Legend Q Smear Location (100cm 2)
All field dose rates in mR/hr
EVESR 534' LEVEL 0.276
)0 DRAIN 0
V),,l{_E
~
l><J VALVE Survey No.
Date:
D-144 12/12/ 22 Surveyor(s)
Name & Signature on Original Document Smear Data t aken 5/25/22 (see RSR2022-0l -0066)
Page 2 of 6 0
0 Map Legend Smear Location (100cm2)
Contact Dose Rate in mR/hr All field dose rates in mR/hr
EVESR 519' LEVEL 8
0.022 Survey No.
D-144 Date:
12/ 12/22 Surveyor(s)
Name & Signature on Original Document Smear Data taken 5/24/ 22 (see RSR2022-01-0061)
Page 3 of6 Map Legend Q Smear Location (100cm 2)
All fi eld dose rates in mR/hr
EVESR 503' LEVEL 0.011 0.011 0.012 0
0.013 0.052 Survey No.
Date:
Surveyor(s)
D-144 12/12/22 Name & Signature on Original Document Smear Data taken 5/24/22 (see RSR2022-01-0062)
Page 4 of 6 Map Legend Q Smear Location (100cm 2)
All field dose rates in mR/hr
EVESR 500' LEVEL IN-CORE FLUX AREA 0
0 0.051 Survey No.
D-144 Date:
12/ 12/22 Surveyor(s)
Name & Signature on Original Document Page 5 of6 Q Contact Dose Rate In mR/hr All ne1d dose c tes in roBLhr
EVESR 487' LEVEL 0.023 0.012 0.046 CRD ROOM 0.052 0
0 Survey No.
Date:
Surveyor(s)
D-144 12/12/22 Name & Signature on Original Document Smear Data taken 5/23/22 (see RSR2022-01-0064)
Page 6 of 6 0
Map Legend Smear Location (100cm 2)
Contact Dose Rate in mR/hr All field dose rate5 in mR/hr
EVESR Contamination Data EVESR 487' 1
<MDA
<MDA RSR2022-01-0064 5/23/2022 EVESR 487' 2
<MDA
<MDA RSR2022-01-0064 5/23/2022 EVESR 487' 3
<MDA
<MDA RSR2022-0l-0064 5/23/2022 EVESR 487' 4
<MDA
<MDA RSR2022-0l-0064 5/23/2022 EVESR 487' 5
<MDA
<MDA RSR2022-01-0064 5/23/2022 EVESR 487' 6
<MDA
<MDA RSR2022-0l-0064 5/23/2022 EVESR 487' 7
<MDA
<MDA RSR2022-0l-0064 5/23/2022 EVESR 503' 8
<MDA
<MDA RSR2022-01-0062 5/24/2022 EVESR 503' 9
<MDA
<MDA RSR2022-01-0062 5/24/2022 EVESR 503' 10
<MDA
<MDA RSR2022-01-0062 5/24/2022 EVESR 503' 11 5771
<MDA RSR2022-01-0062 5/24/2022 EVESR 503' 12 6008
<MDA RSR2022-01-0062 5/24/2022 EVESR 503' 13
<MDA
<MDA RSR2022-01-0062 5/24/2022 EVESR 503' 14 10912
<MDA RSR2022-0l-0062 5/24/2022 EVESR 519' 15
<MDA
<MDA RSR2022-0l-0061 5/25/2022 EVESR 519' 16
<MDA
<MDA RSR2022-01-0061 5/25/2022 EVESR 519' 17
<MDA
<MDA RSR2022-01-0061 5/25/2022 EVESR 519' 18
<MDA
<MDA RSR2022-0l-0061 5/25/2022 EVESR 534' 19
<MDA
<MDA RSR2022-01-0066 5/25/2022 EVESR 534' 20
<MDA
<MDA RSR2022-01-0066 5/25/2022 EVESR 534' 21 2389
<MDA RSR2022-01-0066 5/25/2022 EVESR 534' 22
<MDA
<MDA RSR2022-01-0066 5/25/2022 EVESR 534' 23 2117
<MDA RSR2022-01-0066 5/25/2022 EVESR 549' 24
<MDA
<MDA RSR2022-01-0065 5/19/2022 EVESR 549' 25
<MDA
<MDA RSR2022-01-0065 5/19/2022 EVESR 549' 26
<MDA
<MDA RSR2022-01-0065 5/19/2022 EVESR 549' 27
<MDA
<MDA RSR2022-01-0065 5/19/2022 EVESR 549' 28
<MDA
<MDA RSR2022-01-0065 5/19/2022 EVESR 549' 29
<MDA
<MDA RSR2022-01-0065 5/19/2022 EVESR 549' 30
<MDA
<MDA RSR2022-01-0065 5/19/2022
Air Sample Data for VNC Reactor Annual Inspection At Sample Time After Radon Decay After Radon Decay Reactor Location Date Alpha (uCi/ml) Beta (uCi/ml) Alpha (uCi/ml) Beta (uCi/ml)
Alpha (DAC)
Beta (DAC)
Main Floor 8/25/2022 8.51E-10 2.15E-09 l.37E-14 8.64E-13 0.005 0.000 VBWR Basement 9/21/2022 4.78E-10 l.58E-09 3.21E-14 3.07E-12 0.011 0.002 Fuel Pool 9/21/2022 3.22E-10 l.17E-09 7.78E-14 l.37E-12 0.026 0.001 Main Floor 11/29/2022 2.93E-09 8.88E-09 l.69E-13 2.64E-12 0.056 0.001 EVESR Basement 11/29/2022 4.21E-09 l.12E-08 0.00E+00 5.94E-12 0.000 0.003 519' Level 11/29/2022 3.60E-09 l.05E-08 7.78E-14 6.95E-12 0.026 0.003 Main Floor 11/15/2022 l.53E-10 4.23E-10 2.36E-14 l.35E-12 0.008 0.001 GETR Basement 11/15/2022 l.95E-10 5.44E-10 0.00E+00 l.12E-12 0.000 0.001 Third Floor 11/15/2022 2.16E-10 5.84E-10 l.14E-13 7.65E-13 0.Q38 0.000
GEHitachiNuclearEnergy
VallecitosNuclearCenter
Sunol,California
GENERALELECTRICTESTREACTOR
(DEACTIVATED)
ANNUALREPORTNO.64
FORTHEYEAR2022
LICENSETR1
DOCKET5070
MARCH2023
HITACHI
GETRAnnualReportNo.64
Page1of2
GeneralElectricTestReactor
(Deactivated)
ANNUALREPORTNO.64
GEHitachi(GEH)hasmaintainedtheGeneralElectricTestReactor(GETR)ina
deactivatedstatusundertheauthorityofAmendmentNo.17toLicenseTR1,Docket
5070,issuedOctober22,2007asspecifiedinTS6.6.1toAmendmentNo.14,issued
February5,1986.Inthisannualreport,asummaryofthestatusofthefacilityforthe
periodofJanuary1,2022toDecember31,2022ispresented.
1.0
SUMMARY
ThefacilityremainsinpredominatelythesameconditiondescribedinAnnualReport
No.62.Entryintothereactorbuildingwasmadeforroutineradiationsurveysanda
generalexaminationofconditionsthroughoutthebuilding.Thecrane,elevator,and
ventilationwereservicedandtestedin2022inanticipationofbeginningremediation
activities.Suchactivitieshavenotbegun.
Structuralconditionsandradiationandcontaminationlevelsremainatacceptable
levels.Environmentaldataismaintainedonsiteandavailableforreview.
2.0STATUSOFFACILITY
Inaccordancewithwrittenprocedures,theFacilityManagercontrolsaccesstothe
containmentbuildingandgeneralsystems.Thefacilitycontinuestobeindeactivated
status.TherewerenochangesauthorizedbytheFacilityManagerpursuantto
10CFR50.59(a)in2022.
3.0ROUTINEPATROLS
Thefacilitywasinspectedweekly,quarterly,andannuallyinaccordancewithwritten
stationprocedures.
Thepresenceofminimalefflorescencewasidentifiedonfacilitybasementwallsduring
theannualinspection.Thisconditionwasevaluatedanddeterminedtonotposea
structuralissue.
Thestructuralconditionofthefacilityremainsactivelymonitored,stableand
structurallysoundtoensuremaximumprotectionforpublichealthandsafety.
4.0RADIATIONANDCONTAMINATION
Completeradiationandcontaminationsurveysofthefacilityindicatethatlevelsremain
low.Resultsofthesurveysarepresentedinattachment1.Airsamplingresultsare
GETRAnnualReportNo.64
Page2of2
presentedinattachment2.Theradiation/contaminationlevelslistedarerepresentative
butnotnecessarilymaximumvalues.
4.1
GETRStack
Althoughmaintenancewasperformedonthestackin2022,andthestackwastested,
therehasbeennoremediationeffortperformedfortheGETRreactor.Theventilation
systemisoperational,butnotcurrentlyinuse.
AnalyticalresultsofgroundwatersamplescanbefoundintheAnnualEnvironmental
ReportsubmittedonMarch2,2023.
5.0ACTIVITIES
Inspectionoftheinstalledgaugesshowednopropagationofconcretecracking.
Therewerenopreventiveorcorrectivemaintenanceactivitiesperformedhavingsafety
significanceduringthereportingperiod.
6.0ORGANIZATION
TheSiteManagerisC.Pedley.TheGETRFacilityManagerisJ.G.Ayala.TheManager,
RegulatoryComplianceandEHSremainsJ.Smyly.
7.0CONCLUSION
GEHitachiNuclearEnergyconcludesthatthedeactivatedGETRisbeingmaintainedina
safeshutdowncondition.Theinspections,accesscontrol,andadministratively
controlledactivitiesensuremaximumprotectionforthepublichealthandsafety.The
procedureswillbecontinuedtomaintainthishighlevelofprotection.
GEHitachiNuclearEnergy
VallecitosOperations
C.Pedley,ManagerVallecitosNuclearCenter
CHARLES PEDLEY Digitally signed by CHARLES PEDLEY DN: cn=CHARLES PEDLEY c=US l=7249af3244cf2daca5eb6a8620187dbce5b61cd7 o=MyApps e=223062202@ge.com Reason: I am approving this document Location:
Date: 2023-03-23 10:39-07:00
GETRANNUALSURVEY
GETRSurveys
Contamination
DoseRates
SurveyID
RSR2022010136
RSR2022010152
RSR2022010149
RSR2022010135
C032
SurveyDate(s)
7/11/2022
7/13/2022
12/07/2022
Surveyor
T.Lopez(signatureonoriginals)
M.Arnerich(signatureonoriginal)
Instrument
Ludlum2929
Ludlum3030
RadEye
InstrumentS/N
111575
190648
33155
CalibrationDueDate
9/15/2022
3/7/2023
7/14/2023
I I
ATTACHMENT1
GETR SITE MAP 901. SA),,W:\.E tBm)
LOCATlOt~M 901. SAJ.11'1.E 19ml LCCA"t"OO.s1 SOL ~PLE (&KG)
LOCATIC>>i"2
ATTACHMENT1
\ \ \ 0.360
,-\
\
0 GETR BASEMENT 0.02~
Rx 4
HCA 0.043 0-43
/
0.070
',,..,_,.........,..,..,...,...----r 0
Survey No.
C-032 Date:
12/07 /22 Surveyor(s)
Name & Signature on Original Document Smear Data taken 7 /11/22 (see RSR 2022-01-0136)
Page 5 of 5 0.064 0.031 Step Off Pad CYLINDER STORAGE AREA HCA High Contamination Area Boundary General Area Dose Rate (mrem/hrl Q
Contact Dose Rate (mrem/hr)
Q Smear Location (100 cm2)
ATTACHMENT1
cg]
l!.130.
0.097 GETR 1 ST FLOOR 0.502 **,
Survey No.
C-032 Date:
12/07 /22 Surveyor(s)
Name & Signature on Original Document Smear Data taken 7 /13/22 (see RSR 2022-01-0152}
Page 4 of 5 0
0.126 0
0 0.073
- ',,~',0 0.042 0.010 EQUIPMENT HATCH 0
0 0
Step Off Pad High Contamination Area Boundary General Area Dose Rate (mrem/ hr)
Contact Dose Rate (mrem/ hr)
Smear Location (100 cm2)
ATTACHMENT1
GETR MEZZANINE (OPEN AREA) 0.014 0.011 0.023 0.015 Survey No.
C-032 Date:
12/07 /22 Surveyor(s)
Name & Signature on Original Document Page 3 ofS HCA 0
Step Off Pad High Contamination Area Boundary General Area Dose Rate (mrem/hr)
Contact Dose Rate (mrem/hr)
ATTACHMENT1
GETR 2ND FLOOR 0.026 0
0 Survey No.
C-032 Date:
12/07 /22 Surveyor(s)
Name & Signature on Original Document Smear Data taken 7 /13/22 (see RSR 2022-01-0149)
Page 2 of 5 Step Off Pad High Contamination Area Boundary General Area Dose Rate (mrem/hr)
Contact Dose Rate (mrem/hr)
Smear Location (100 cm2)
ATTACHMENT1
GETR 3RD FLOOR O.OS9 0.077 DRA1fl 0 REACTOR CAVITY FUEL~
0_24J3RIDG~
0.038 Survey No.
C-032 Date:
12/07 /22 Surveyor(s)
Name & Signature on Original Document Smear Data taken 7 /11/22 (see RSR 2022-01-0135)
Page 1 of 5 0.035 RAISED PLATFORM AREA 0.010 0.020 0
0 0.020 Step Off Pad High Contamination Area Boundary General Area Dose Rate (mrem/hr)
Contact Dose Rate (mrem/hr)
Smear Location (100 cm2)
ATTACHMENT1
GETR Contamination Data DIiie GETR L552 (BSMT) 1
< MDA
< MDA RS2022-01-0136 7/11/2022 GETR L552 (BSMT) 2
< MDA
< MDA RS2022-01-0136 7/11/2022 GETR L552 (BSMT) 3
< MDA
< MDA RS2022-01-0136 7/11/2022 GETR L552 (BSMT) 4 5687
< MDA RS2022-01-0136 7/11/2022 GETR L552 (BSMT) 5 589
< MDA RS2022-01-0136 7/11/2022 GETR L552 (BSMT) 6 202754 14 RS2022-01-0136 7/11/2022 GETR L552 (BSMT) 7 4791
< MDA RS2022-01-0136 7/11/2022 GETR L552 (BSMT) 8
< MDA
< MDA RS2022-01-0136 7/11/2022 GETR L567 (1st Fl) 9
< MDA
< MDA RS2022-01-0152 7/13/2022 GETR L567 (1st Fl) 10 143
< MDA RS2022-01-0152 7/13/2022 GETR L567 (1st Fl}
11 174
< MDA RS2022-01-0152 7/13/2022 GETR L567 (1st Fl}
12 808
< MDA RS2022-01-0152 7/13/2022 GETR L567 (1st Fl}
13 79986
< MDA RS2022-01-0152 7/13/2022 GETR L567 (1st Fl}
14 20621
<MDA RS2022-01-0152 7/13/2022 GETR L567 (1st Fl}
15 908
< MDA RS2022-01-0152 7/13/2022 GETR L567 (1st Fl}
16 1133
< MDA RS2022-01-0152 7/13/2022 GETR L567 (1st Fl) 17 101
< MDA RS2022-01-0152 7/13/2022 GETR L589 (2nd Fl) 18
< MDA
< MDA RS2022-01-0149 7/13/2022 GETR L589 (2nd Fl) 19
< MDA
< MDA RS2022-01-0149 7/13/2022 GETR L589 (2nd Fl) 20 1703
< MDA RS2022-01-0149 7/13/2022 GETR L589 (2nd Fl) 21 16654
< MDA RS2022-01-0149 7/13/2022 GETR L589 (2nd Fl) 22 31086
< MDA RS2022-01-0149 7/13/2022 GETR L589 (2nd Fl) 23
< MDA
< MDA RS2022-01-0149 7/13/2022 GETR L589 (2nd Fl) 24
< MDA
< MDA RS2022-01-0149 7/13/2022 GETR L589 (2nd Fl) 25
< MDA
< MDA RS2022-01-0149 7/13/2022 GETR L611 (3rd Fl}
26 1023175
< MDA RS2022-01-0135 7/11/2022 GETR L611 (3rd Fl}
27
< MDA
< MDA RS2022-01-0135 7/11/2022 GETR L611 (3rd Fl}
28
< MDA
< MDA RS2022-01-0135 7/11/2022 GETR L611 (3rd Fl}
29
< MDA
< MDA RS2022-01-0135 7/11/2022
Air Sample Data for VNC Reactor Annual Inspection At Sample Time After Radon Decay After Radon Decay Reactor Location Date Alpha (uCi/ml) Beta (uCi/ml) Alpha (uCi/ml) Beta (uCi/ml)
Alpha (DAC)
Beta (DAC)
Main Floor 8/25/2022 8.51E-10 2.15E-09 l.37E-14 8.64E-13 0.005 0.000 VBWR Basement 9/21/2022 4.78E-10 l.58E-09 3.21E-14 3.07E-12 0.011 0.002 Fuel Pool 9/21/2022 3.22E-10 l.17E-09 7.78E-14 l.37E-12 0.026 0.001 Main Floor 11/29/2022 2.93E-09 8.88E-09 l.69E-13 2.64E-12 0.056 0.001 EVESR Basement 11/29/2022 4.21E-09 l.12E-08 0.00E+00 5.94E-12 0.000 0.003 519' Level 11/29/2022 3.60E-09 l.05E-08 7.78E-14 6.95E-12 0.026 0.003 Main Floor 11/15/2022 l.53E-10 4.23E-10 2.36E-14 l.35E-12 0.008 0.001 GETR Basement 11/15/2022 l.95E-10 5.44E-10 0.00E+00 l.12E-12 0.000 0.001 Third Floor 11/15/2022 2.16E-10 5.84E-10 l.14E-13 7.65E-13 0.Q38 0.000