Review of Final License Renewal Interim Staff Guidance LR-ISG-2011-03 Changes to the Generic Aging Lessons Learned (GALL) Report Revision 2 Aging Management Program XI.M41, Buried & Underground Piping and Tanks & Update to License Renewal
ML14191A632
Person / Time
Site: South Texas  
Issue date: 06/26/2014
From: Gerry Powell
South Texas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
LR-ISG-2011-03, NOC-AE-14003149, TAC ME4936, TAC ME4937
Download: ML14191A632 (23)


Text

Nuclear Operating Company South Texas Proped Electric Generating Station PO. Bo 289 Wdsaorth, Teuas 77483 AA June 26, 2014 NOC-AE-14003149 10 CFR 54 File: G25 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 South Texas Project Units 1 and 2 Docket Nos. STN 50-498, STN 50-499 Review of Final License Renewal Interim Staff Guidance LR-ISG-2011-03 "Changes to the Generic Aging Lessons Learned (GALL) Report Revision 2 Aging Management Program XI.M41, "Buried and Underground Piping and Tanks" and update to License Renewal Application (TAC Nos. ME4936 and ME4937) m

References:

1. Letter from G. T. Powell, STPNOC, to NRC Document Control Desk, "License Renewal Application", dated October 25, 2010 (NOC-AE-1 0002607)

(ML103010257)

2. Final License Renewal Interim Staff Guidance LR-ISG-2011-03 "Changes to the Generic Aging Lessons Learned (GALL) Report Revision 2 Aging Management Program XI.M41, "Buried and Underground Piping and Tanks" (ML12138A296)
3. Letter from G.T. Powell, STPNOC, to NRC Document Control Desk, Response to Request for Additional Information for the Review of the South Texas Project, Units 1 and 2, License Renewal Application - Set 27 dated June 3, 2014 (NOC-AE-14003141)

By Reference 1, STP Nuclear Operating Company (STPNOC) submitted a License Renewal Application (LRA) for South Texas Project (STP) Units 1 and 2. By Reference 2, the NRC staff provides additional guidance for review of the STP LRA Aging Management Program XI.M41.

STPNOC's review and changes to LRA Aging Management Program XI.M41 is depicted as line-in/line-out pages provided in Enclosure 1.

This correspondence provides supplemental information regarding the review of ISG 2011-03, pertaining to "Buried and Underground Piping and Tanks" inadvertently omitted in Reference 3.

The NRC license renewal staff was notified per telecom on 6/11/2014 of the discrepancy. includes revised regulatory commitment Item #13 depicted as line-in/line-out pages to Table A4-1 of the LRA. There are no other regulatory commitments in this letter.

STI: 33889306

NOC-AE-14003149 Page 2 of 3 Should you have any questions regarding this letter, please contact either Arden Aldridge, STP License Renewal Project Lead, at (361) 972-8243 or Rafael Gonzales, STP License Renewal Project regulatory point-of-contact, at (361) 972-4779.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on Date G.T. Powell Site Vice President RJG

Enclosures:

1.

STPNOC Response to LR-ISG-2011-03 and LRA Changes with Line-in/Line-out Annotations

2.

STPNOC Regulatory Commitments

NOC-AE-14003149 Page 3 of 3 cc:

(paper copy)

(electronic copy)

Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, Texas 76011-4511 Balwant K. Singal Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 8B1) 11555 Rockville Pike Rockville, MD 20852 Senior Resident Inspector U. S. Nuclear Regulatory Commission P. O. Box 289, Mail Code: MN116 Wadsworth, TX 77483 John W. Daily License Renewal Project Manager (Safety)

U.S. Nuclear Regulatory Commission One White Flint North (MS 011-Fl)

Washington, DC 20555-0001 Tam Tran License Renewal Project Manager (Environmental)

U. S. Nuclear Regulatory Commission One White Flint North (MS 011 F01)

Washington, DC 20555-0001 A. H. Gutterman, Esquire Kathryn M. Sutton, Esquire Morgan, Lewis & Bockius, LLP John Ragan Chris O'Hara Jim von Suskil NRG South Texas LP Kevin Polio Cris Eugster L.D. Blaylock CPS Energy Peter Nemeth Crain Caton & James, P.C.

C. Mele John Wester City of Austin Robert Free Texas Department of State Health Services Richard A. Ratliff Texas Department of State Health Services Balwant K. Singal John W. Daily Tam Tran U. S. Nuclear Regulatory Commission NOC-AE-14003149 STPNOC Response to LR-ISG-2011-03 and LRA Changes with Line-in/Line-out Annotations NOC-AE-14003149 Page 1 of 12 Guidance from LR-ISG-2011-03 INTRODUCTION This final license renewal interim staff guidance (LR-ISG) LR-ISG-2011-03, "Changes to the Generic Aging Lessons Learned (GALL) Report Revision 2 Aging Management Program (AMP)XI.M41, 'Buried and Underground Piping and Tanks'," provides changes to GALL Report AMP XI.M41 as described below. The AMP, as modified herein, provides one acceptable approach for managing the effects of aging of buried and underground piping and tanks within the scope of the License Renewal Rule (Title 10 of the Code of Federal Regulations, Part 54, "Requirements for Renewal of Operating Licenses for Nuclear Power Plants" (10 CFR Part 54)).

This LR-ISG also changes Table 3.0-1, "FSAR Supplement for Aging -Management of Applicable Systems," in the Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants (SRP-LR). A licensee may reference this ISG in its license renewal application (LRA) to demonstrate that its buried underground piping and tanks program is acceptable to the staff until the guidance in this LR-ISG is implemented into the next update of the license renewal guidance documents.

STPNOC Response:

The following provides the line-in/line-out details on how STP is applying the updated guidance of LR-ISG-2011-03 into the "License Renewal Application aging management program" (AMP XI.M41).

NOC-AE-14003149 Page 2 of 12 A1.18 Buried Piping and Tanks Inspection The Buried Piping and Tanks Inspection program manages the loss of material on external surfaces of buried and underground limit8d acce components. Preventive and mitigative measures, including verification of coatings quality, backfill requirements, and cathodic protection, are employed to manage aging of buried components. Underground components have been are protectively coated where required.

The cathodic protection system is operated consistent with the guidance of NACE SP01 69-2007 for piping and is monitored to ensure that protection is being provided. The cathodic protection system is operational (available) at least 85 percent of the time and provides effective protection for buried piping as evidenced by meeting the acceptance criteria at least 80 percent of the time since either 10 years prior to the period of extended operation or since installation or refurbishment. An annual cathodic protection survey is performed consistent with NACE SP0169-2007.

Opportunistic and directed visual inspections will monitor the condition of external surfaces, protective coatings and wrappings found on steel, stainless steel and copper alloy components.

Any evidence of damaged wrapping or coating defects will be an indicator of possible corrosion damage to the external surface of the components.

Hydrostatic tests of 25 percent of the subiect piping will be performed on an interval not to exceed 5 years, or an internal inspection of 25 percent of the subiect piping by a method capable of accurately determining pipe wall thickness every 10 years may be performed as an alternate to directed inspections. Flow testing of the fire mains as described inSection 7.3 of NFPA 25, 2011 Edition is credited in lieu of visual inspections.

NOC-AE-14003149 Page 3 of 12 B2.1.18 Buried Piping and Tanks Inspection Program Description The Buried Piping and Tanks Inspection program manages the loss of material on external surfaces of buried and underground limited accesG components.

The Buried Piping and Tanks Inspection program includes inspections or flow testinq of buried steel, stainless steel, copper alloy piping, underground steel, stainless steel piping within the Auxiliary Feedwater System, the Lighting Diesel Generator System, the Essential Cooling Water (ECW) and ECW Screen Wash System, the Fire Protection System, and the Oily Waste System (OW).

Preventive and mitigative actions are taken to ensure the pipinge is coated, backfilled and cathodically protected. The buried steel and copper alloy piping managed by this program is cathodically protected, and the cathodic protection system is monitored to ensure it is providiRg prot9ctiGR. The cathodic protection system is designed in accordance with NACE RP-01-69 1972. The performance of the cathodic protection system is consistent with the guidelines of NACE SP0169-2007. An annual survey ensures that the pipe-to-soil potential is acceptable.

Cathodic protection is operational (available) at least 85 percent of the time from either 10 years prior to the period of extended operation or from installation or refurbishment, whichever is shorter. Cathodic protection is effective protection for buried piping as evidenced by meeting the acceptance criteria at least 80 percent of the time since either 10 years prior to the period of extended operation or since installation or refurbishment, whichever is shorter.

Opportunistic and directed visual inspections monitor the condition of the external surfaces, backfill, protective coatings and wrappings of steel, stainless steeland copper alloy buried and

,,de,....GI-components.

Inspection locations are selected based on susceptibility to degradation and consequences of failure. A minimum of 10 feet of pipe of each material type is inspected. The inspections consist of a 100 percent visual inspection of the exposed pipe.

Category C inspections are used when the external cathodic protection system for buried steel or copper alloy pipe meets the acceptance criteria. Category C inspections are 0.5 percent Not-to-Exceed (NTE) two inspections of that piping per inspection period.

Category E inspections are used when the cathodic protection system has been installed but portions of the piping covered by that system fail to meet the acceptance criteria. Category E inspections are 5 percent, NTE 10 inspections, in years 30 to 40: 6 percent, NTE 15 inspections, in years 40 to 50: and 7.5 percent, NTE 18 inspections, in years 50 to 60.

The Auxiliary Feedwater system has stainless steel pipe underground in a vault outside of the Auxiliary Feedwater Storage tank. This stainless steel pipe will undergo two directed visual inspections each 10-year inspection period.

The OW system has steel pipe under-ground in sumps located in the yard. This underground pipe will undergo 2% NTE 4 directed visual inspection each 10-year inspection period.

NOC-AE-14003149 Page 4 of 12 In lieu of visual inspections of the fire protection system, STP credits flow testing of the fire mains as described in Section 7.3 of NFPA 25, 2011 Edition.

Inspections will begqin during the 10-year period prior to entering the period of extended operation. Upon entering the period of extended operation, inspections will occur every 10 years.

Visual inspections of metallic components are supplemented with surface or volumetric nondestructive testing (NDT) if significant indications are observed to determine local area wall thickness. If adverse indications are detected, inspection sample sizes within the affected piping categories are doubled. If adverse indications are found in the expanded sample, further increases in inspection sample size is based on an analysis of extent of cause and extent of condition.

Hydrostatic test of 25 percent of the subiect piping on an interval is not to exceed 5 years, or internal inspection of 25 percent of the subiect piping by a method capable of accurately determining pipe wall thickness every 10 years may be performed as an alternate to directed inspections.

There are no components fabricated with polymeric, cementitious, or concrete materials within the scope of license renewal that credit this program for aging management. There are no buried or underground tanks within the scope of license renewal.

Any evidence of aging effects, such as loss of material, racki~ng or changes in material properties, requires initiation of corrective actions.

The c~athodic protection system; is sureyed annually to ensure that it is 6upplying adoquato.

protection to buried piping*,,

The program includes visual iunspection of etn surface'

.pplemented by sur.face and/o vmIc,,-,-non destr*c.tive testing of the inte*al or extera*l surfafce during opportunistic o planned inspections. Hydrotesting m~ay be porfo~rm~ed in liou of directod inspections.

Aging management of the internal surfaces of buried and underground piping is accomplished through the use of the Open-Cycle Cooling Water System program (B2.1.9), Closed-Cycle Cooling Water System program (B2.1.10), Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program (B2.1.22), Fuel Oil Chemistry program (B2.1.14),

Fire Water System program (B2.1.13) and Water Chemistry program (B2.1.2). Selective leaching of buried or underground components is managed by the Selective Leaching of Materials program (B2.1.17) or the Selective Leaching of Aluminum Bronze program (B2.1.37).

NUREG-1801 Consistency The Buried Piping and Tanks Inspection program is an existing program that, following enhancement, will be consistent with exception to NUREG-1801,Section XI.M41, Buried and Underground Piping and Tanks.

Exceptions to NUREG-1801 Program Elements Affected:

Preventive Actions (Element 2)

NOC-AE-14003149 Page 5 of 12 Section XI.M41 Table 2a of NUREG-1801 Revision 2, requires the backfill to be consistent with NACE SP0169 Section 5.2.3.

NACE SP0169 Section 5.2.3.5 states that pipe should be lowered carefully into the ditch to avoid external coating damage. The original installation specification does not include this practice. However the subgrade of the trench was prepared by removing all debris and unsuitable material, and the subgrade consists of fine clay and sand that makes up the natural soil or backfill.

The backfill used is consistent with the ASTM D 448-08 size 67 standard. The subgrade preparation, and small grain size backfill used in the original installation, which provide soft bedding for piping set into the trench, are not expected to have damaged the coating of the piping. Plant procedures will be enhanced to ensure that the piping is lowered carefully into a trench to avoid damage to the external coatings.

Section XI.M41 Table 2a of NUREG-1801 Revision 2, requires that backfill be consistent with NACE SP0169 Section 5.2.3. NACE SP0169 Section 5.2.3.6 states that care should be taken during backfilling so that rocks and debris do not strike and damage the pipe coating. The original installation specification for backfilling piping does not include this practice, with the exception of the ECW piping. However a fine grain size backfill was used that met the ASTM D 448-08 size 67 standard. The use of this backfill during backfilling is not expected to damage the pipe coating. Plant procedures will be enhanced so that, during backfill repair or replacement, care is taken to avoid damage to pipe coatings while backfilling the trench.

Section XI.M41 Table 2a of NUREG-1801 Revision 2, requires coating of pipe in accordance with NACE SP0169-2007, Table 1. Table 1 recommends that coal tar coatings are in accordance with AWWA C-203, and that prefabricated films are in accordance with AWWA C-214 or C-209. These standards were not referenced in STP installation specifications.

However, the coatings were applied in accordance with plant-defined specifications. Plant specifications are consistent with the intent of the AWWA coating standards called out in NACE SP0169-2007. Installation specifications ensure that any defects in the coatings were repaired prior to backfilling over the pipe.

Enhancements Prior to the period of extended operation, the following enhancements will be implemented in the following program elements:

Preventive Actions (Element 2)

Plant specifications will be enhanced to include the following:

Indicate that pipe should be lowered carefully into the ditch to avoid external coating damage.

Proper storage and handling must be used to prevent damage to pipe coating prior to installation. These practices include padded storage, use of proper slings for installation and ultraviolet light-resistant topcoats.

Over-excavate trenches and use qualified backfill for bedding piping. Take care during backfilling to prevent rocks and debris from striking and damaging the pipe coating.

NOC-AE-14003149 Page 6 of 12 Include the coating used for copper alloy buried piping in the coating database. The coating system must be in accordance with NACE SP0169-2007, Table 1, and will be used for repair or for new coatings of the buried copper alloy piping in the essential cooling water system.

Indicate that the portion of the essential cooling water system copper alloy piping directly embedded in backfill or directly encased in concrete must be coated, extending the coating 2 feet or more above grade.

Plant procedures will be enhanced to include the following:

Backfill that is located within 6 inches of the pipe that is consistent with ASTM D 448-08 size number 67 is considered acceptable. Backfill quality is determined through examination during the inspections conducted by this program. Backfill that does not meet the ASTM criteria during the initial and subsequent inspections of this program is considered acceptable if the inspections of buried piping do not reveal evidence of mechanical damage to the pipe coatings due to the backfill.

The cathodic protection system engineer is responsible for ensuring the cathodic protection system survey is performed annually, and the rectifier current is checked and recorded every 2 months.

Monitor cathodic protection system rectifier output every 2 months. The measured current at each rectifier is recorded and compared against a target value. Following completion of the plant yard cathodic protection system annual survey, record the current of the rectifier used to achieve an acceptable pipe/soil potential. That current will be the target current for the rectifier. If the current measured at the rectifier during the bimonthly monitoring deviates significantly from the target value, a condition report should be created. The rectifier current should be adjusted to an acceptable value.

The results of the survey will be documented and trended to identify degrading conditions. When degraded rectifier performance is identified, corrective actions are required to be initiated. The system should not be operated outside of established acceptable limits for longer than 90 days.

During the plant yard cathodic protection system annual survey, evaluate the effectiveness of isolating fittings, continuity bonds and casing isolation. This may be accomplished through electrical measurements (NACE SP0169-2007, Section 10.4.4).

The P,6rformanc tAo"*chGnicnr personnel performinq the plant yard cathodic protection system annual survey must be NACE-certified, certified by a site-approved training procedure consistent with the NACE requirements, or supervised by a NACE-certified inspector.

Parameters Monitored/Inspected (Element 3) and Detection of Aging Effects (Element 4)

Plant procedures will be enhanced to indicate that piping in this program is inspected using visual inspections and, if significant indications of degradation are observed, the visual inspections are supplemented by surface and/or volumetric non-destructive testing.

NOC-AE-14003149 Page 7 of 12 Detection of Aging Effects (Element 4)

Plant procedures will be enhanced to include the following:

0 The inspections of this program are conducted every 10 years, beginning in the 10 year interval prior to the beginning of the period of extended operation.

0 Buried and underground piping inspection locations are to be selected based on risk, considering susceptibility to degradation and consequences of failure.

0 The risk ranking for buried piping should consider characteristics such as coating type, coating condition, cathodic protection effiGaey efficiency, backfill characteristics, soil resistivity, pipe contents, and pipe function.

0 The risk ranking for underground piping should consider characteristics such as coating type, coating condition, exact external environment, pipe contents, pipe function, and flow characteristics within the pipe.

0 The risk ranking should generally give piping systems that are backfilled using compacted aggregate a higher inspection priority than comparable systems that are completely backfilled using controlled low strength material.

External Corrosion Direct Assessment, as described in NACE Standard Practice SP0502-2010, is recommended for use in identifying inspection locations. It has been demonstrated to be an effective method for identification of pipe locations that merit further inspection.

Opportunistic examinations of non-leaking pipes may be credited toward the required examinations, if they meet the risk-ranking selection criteria.

Guided wave ultrasonic techniques or other advanced inspection techniques should be used, if practical, for determining piping locations that should be inspected. However, these inspections may not be used as substitutes for inspections required by this program.

An inspection of piping shared between Units 1 and 2 may eiy-be credited toward the required inspections-ef-ene-RWi. Inspection quantities are increased by 50 percent as STP has two units.

Any piping, valves, or closure bolting exposed during inspections should be examined.

Examine bolting for loss of material and loose or missing fasteners.

There are two alternatives to directed inspections of the buried or underground piping that is safoty relatod, hazmat or bothwithin the scope of license renewal. The first alternative is a hydrostatic test of 25 percent of the subject piping to 110 percent of the design pressure of any component within the boundary with test pressure being held for eight hours n aGccordanco with 49 CFR 195 subpa*t E on an interval not to exceed 5 years. The second is an internal inspection of 25 percent of the subject piping by a method capable of accurately determining pipe wall thickness. The inspection must also include methods capable of detecting both general and pitting corrosion, and must be qualified by the plant, and approved by the NRC.

NOC-AE-14003149 Page 8 of 12 UT examinations can be considered approved by the NRC. Guided wave inspection does not currently satisfy these inspection technique requirements. Internal inspections are to be conducted every 10 years beginning 10 years prior to the period of extended operation.lf this inspection iporormed,4 considerationm should be given to NACE SP0169 2007 Sections 6.1.2 and 6.3.3.

In lieu of visual inspection of the fire protection system, this program relies on flow testing of the fire mains as described in Section 7.3 of NFPA 25, 2011 Edition to detect degradation of the buried pipe.

Define "haz-mat pipe" as pipe that, dluig nRarl peratioR, cort-ntais fluids; that i released, would be-derientlt the environmet. This inclu,6des chem~ical suibstances6 such as diesel fuel and radi-o..i-.otpeG. TO 1be conSidered hazmat, the concentration o.

radioisotopes within the Pipe durFing normnal operation m;ust exceed established standadrds suc-h as the EMPA drinking water standard. In the a-bsen-e of suhstaand-ardsE, the concentra-tion-of the radioisotope mus1t exceed the greater of backgroun~d or reliable level of detoctetion. For tritium, the E=PA drinking water standard of (20,000 pCi!L) i Each inspection will examine either the entire length of a run of pipe, or a minimum of 10 feet. If the entire run of pipe of that material type is less than 10 feet in total length, then the entire run of pipe should be inspected. The inspection consists of a 100 percent visual inspection of the exposed pipe.

Category C inspections are used when the external cathodic Protection system for buried steel or copper alloy pipe meets the acceptance criteria. Category C inspections are 0.5 percent Not-to-Exceed (NTE) two inspections of that piping per inspection period are performed.

Category E inspections are used when the cathodic Protection system has been installed but the portions of the piping covered by that system fail to meet the acceptance criteria. Category E inspections are 5 percent, NTE 10 inspections, in years 30 to 40: 6 percent, NTE 15 inspections, in years 40 to 50: and 7.5 percent, NTE 18 inspections, in years 50 to 60. The following condition must be present.

a)

Coatings and backfill are provided in accordance with STP backfill specification.

b)

There have been no leaks in buried piping due to external corrosion and no significant coating degradation or metal loss in more than 10 percent of inspections conducted.

c)

Soil has been demonstrated to be not corrosive for the material type.

The inspection scope for piping that does not meet Category C or E inspection schedule reguirements is 10 percent, NTE 23 inspections, in years 30 to 40: 12 percent, NTE 30 inspections, in years 40 to 50: and 15 percent, NTE 38 inspections, in years 50 to 60.

1fThe AF system underground stainless steel piping located in a vault will undergo two insarections each 10-yer inspection period.

NOC-AE-14003149 Page 9 of 12 The OW system underground piping will undergo 2% NTE 4 inspection each 10-year inspection period.

Cathodic protection shall be operational (available) at least 85 percent of the time since either 10 years prior to the period of extended operation or since installation or refurbishment, whichever is shorter.

Cathodic protection shall provide effective protection for buried piping at least 80 percent of the time since either 10 years prior to the period of extended operation or since installation or refurbishment, whichever is shorter.

As found results of annual surveys are to be used to demonstrate locations within the plant's population of buried pipe where cathodic protection acceptance criteria have, or have not, been met.

Indicate that adverse indications discovered during the monitoring of the cathodic protection system may warrant increased monitoring of the cathodic protection system and/or additional inspections.

Include examples of adverse indications discovered during piping inspections including leaks, material thickness less than minimum, and general or local degradation of coatings that exposes the base material. The presence of coarse backfill within 6 inches of a coated pipe or tank, with accompanying coating degradation, is considered an adverse condition.

Adverse indications that fail to meet the acceptance criteria described in this program require corrective actions for the repair or replacement of the affected component.

An analysis may be conRducted to determine the potential extent of the degradation obser-ed. Expansion of sample siz.e m.ay be limnited to the piping or taRnks.subject to thee observed degradation mechanism.

If adverse indications are detected in safety related or hazmat piping, inspection sample sizes within the affected piping categories are doubled. If adverse indications are found in the expanded sample, an analysis is conducted to determine the extent of condition and extent of cause. the inspection.am.pl size is again doubled. This doubling of the inspect!in sample size continues until no more adverse co.nditions are found. The size of the follow-on inspections will be determined based on the extent of condition and extent of cause. The timing of the additional examinations should be based on the severity of the degradation identified and should be commensurate with the consequences of a leak or loss of function, but in all cases, the expanded sample inspections should be completed within the 10-year interval in which the original adverse condition was identified. Expansion of the sample size may be limited by the extent of piping subiect to the observed degradation mechanism. If adverse conditions are extensive, inspections may be halted in an area of concern that is planned for replacement, provided continued operation does not pose a significant hazard.

Define the scope of inspection for buried pipi uing the criteria in Section XI.M41 Table 4a of NUFREG 1801, Revisio 2. The scope Of inspection is O tho codtOnf cathodic protection, backfill and-coa-ting of the piping NOC-AE-14003149 Page 10 of 12 Ensure the scope of inpcinicossWhen the cathodic protection systomA doosno Meot operability requ1irem:ents Or the backfill doeS not Meet the bac-kfill -acceptance

crieri, a pcifed n

Setinm X[MI Tabl

la o; f NiRE 1 80CZ1.Q Reqviionm 2L p
  • n I

i

  • 11 i

i I i

  • A f I

f I

I i

  • i I iI

.ac-h inspection Of urled piping w.ll exam..ne at least 1U feet ot p.png. if the entire length of piping i6 less than 10 foot, inspect the entire length. Piping.,: oF each Materia type mus6t be inspected.

Regardless of the inspection scope prescribed by Section Xl.441 Table 4a of NUJREG 1801, Revision 2, the isetosmay be limited to 10 preFnt of the pipin6 uRder coRnideration.

i Regardlessq of the oniGAW1tion of the bhac-kfill and coatings, only one inspection is required of all bur~ied stainless steel safety related piping du1Frin each 10) year inpcto AitR;a The safety related unRderground stainless, steel pipe in the auxiliar-' feedwater systemn MUMt be inspected once every ten years-.

During the inspection of buried piping, observe for brittle failure at flanges, connections, and joints due to frost heaving, soil stresses, or ground water effects.

Monitoring and Trending (Element 5)

Plant procedures will be enhanced to include the following:

di-eet-Direct the cathodic protection system engineer to trend results of the plant yard cathodic protection system annual surveys, so that changes in the effectiveness of the cathodic protection system and coating of buried piping can be verified.

Where wall thickness measurements are conducted, the results should be trended if follow-up examinations are conducted.

Acceptance Criteria (Element 6)

Plant procedures will be enhanced to include the following:

The cathodic protection system pipe-to-soil potential when using a saturated copper/copper sulfate reference electrode must be between -850 mV instant off and -

1200 mV. The cathodic protection system is operational (available) at least 85 percent of the time and provides effective protection for buried piping as evidenced by meeting the acceptance criteria at least 80 percent of the time since either 10 years prior to the period of extended operation or since installation or refurbishment.

For coated piping, there should be no evidence of coating degradation. If coating degradation is present, it may be considered acceptable if it is determined to be insignificant by an individual possessing a NACE Coating Inspector Program Level 2 or 3 inspector qualification, or an individual has attended the Electric Power Research Institute (EPRI) Comprehensive Coatings Course and completed the EPRI Buried Pipe Condition Assessment and Repair Training Computer Based Training Course.pef-atef qualification, Gr OtheFrWie meeting the qu5alifications to e eatings as described in 49 CER 192 and 195.

NOC-AE-14003149 Page 11 of 12 Where damage to the coating has been evaluated as significant and the damage was caused by non-conforming backfill, an extent of condition evaluation should be conducted to ensure that the as-left condition of backfill in the vicinity of observed damage will not lead to further degradation.

Backfill is acceptable if it is consistent with SP0169-2007 Section 5.2.3. Backfill that is located within 6 inches of steel pipe that meets ASTM D 448-08 size number 67 is consistent with the objectives of SP0169-2007.

For any hydrostatic tests credited by this program, the condition acceptance criteria is no visible indications of leakage and no drop in pressure within the isolated portion of the piping that is not accounted for by a temperature change in the test media or quantified leakage across test boundary valves"with-ut loakage", as requird*

by 49 CF=R 19P5.2302, may be met by demonstrating thttets pressure, as adjustedfo temperature, doeS nt var, during the test.

Detectonr ef Aging Efffects (Elemert 4) and Acceptance Criteria (Elemert 6) ie tthe systemns wothese bried Or underelgrd piping Within the scope of ths progranm.

The li st sheoud coentain whether the pope is fty 9Frelt o hazcrat frnf each piping material and sytema within the og.pe Of thi program. Indicate whether ore nt the coating, backfill an d c

athodi e

psrotetin of this piing e in c-mpliano With NAREp SFh 169 des207 c

anbdi the ether requirements f Se actriontd 41, Table 2a of N REiG 181, ReV*GueR 2.

Operating Experience A 10-year review of plant operating experience shows 30 events which were associated with buried piping. Nine of these events were related to systems or components in scope of license renewal. All of these events were leaks shown to not be a result of corrosion of materials, making them not relevant to this program. The program includes availability, reliability, maintainability, and capacity measurement analyses, published in bi-annual Health Reports.

The events described in the Health Reports are all attributed to causes other than corrosion due to contact with an aggressive environment (most leaks were associated with mechanical joints).

The need to enhance the STP Buried Piping program was initially identified by INPO as an area for improvement. Since that time, involvement with the industry has identified areas for program enhancement. Enhancement of the program is ongoing, utilizing guidance from NEI 09-14 Revision 1, Guideline for the Management of Buried Piping Integrity, and industry operating experience.

The following industry operating experience was reviewed to identify aging effects applicable to STP.

In February 2005, a leak was detected in a 4-inch condensate storage supply line. The cause of the leak was microbiologically influenced corrosion (MIC) or under deposit corrosion. MIC and under deposit corrosion are typically internal corrosion, and managed by the Water Chemistry program (B2.1.2) and verified with the One-Time Inspection program (B2.1.16).

NOC-AE-14003149 Page 12 of 12 In September 2005, a service water leak was discovered in a buried service water header. The header had been in service for 38 years. The cause of the leak was either failure of the external coating or damage caused by improper backfill. STP has a very fine grain of the natural soil, and the installation specifications for backfilling require a backfill that is consistent with ASTM D-448 08 size number 67. Considering this, there is a low probability that pipe coatings have sustained damage due to backfill. The cathodic protection system is operated in accordance with NACE SP0169 and will assure that the piping has a low probability of corrosion, even in the event of coating degradation or failure.

In October 2007, degradation of essential service water piping was reported. The riser pipe leak was caused by a loss of pipe wall thickness due to external corrosion induced by the wet environment surrounding the unprotected carbon steel pipe. This degradation is not expected at STP, as all steel and copper alloy piping managed by this program are coated and cathodically protected.

In February 2009, a leak was discovered on the return line to the condensate storage tank.

The cause of the leak was coating degradation, probably due to the installation specification not containing restrictions on the type of backfill, allowing rocks in the backfill.

STP has a very fine grain of the natural soil, and the installation specifications for backfilling require a backfill that is consistent with ASTM D-448 08 size number 67. Considering this, there is a low probability that pipe coatings have sustained damage due to backfill. Plant specifications will be enhanced to prevent rocks and debris from striking the pipe coatings during the backfill of piping. The cathodic protection system is operated in accordance with NACE SP0169 and will assure that the piping has a low probability of corrosion, even in the event of coating degradation or failure.

In April 2009, a leak was discovered in an aluminum pipe where it went through a concrete wall. This leak is not relevant to STP, as the plant has no buried aluminum piping that requires management by this program.

In June 2009, an active leak was discovered in buried piping associated with the condensate storage tank. The leak was discovered because elevated levels of tritium were detected. The cause of the through-wall leak was determined to be degradation of the protective moisture barrier wrap, which allowed moisture to come in contact with the piping, resulting in external corrosion. STP inspected pipe coatings during installation, and verified an acceptable condition of wrap as it was installed. The cathodic protection system is operated in accordance with NACE SP0169 and will assure that the piping has a low probability of corrosion, even in the event of coating degradation or failure. The inspection of high risk piping by this program can be used to verify that this degradation is unlikely at STP.

The Buried Piping and Tanks Inspection program requires review of plant and industry operating experiences for impacts to the program. This program ensures long-term strategies to address Buried Piping and Tank Inspection are developed and implemented.

Conclusion The continued implementation of the Buried Piping and Tanks Inspection program provides reasonable assurance that aging effects are managed such that the systems and components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis for the period of extended operation.

NOC-AE-1 4003149 STPNOC Regulatory Commitments NOC-AE-14003149 Page 1 of 6 A4 LICENSE RENEWAL COMMITMENTS Table A4-1 identifies proposed actions committed to by STPNOC for STP Units 1 and 2 in its License Renewal Application. These and other actions are proposed regulatory commitments. This list will be revised, as necessary, in subsequent amendments to reflect changes resulting from NRC questions and STPNOC responses. STPNOC will utilize the STP commitment tracking system to track regulatory commitments. The Condition Report (CR) number in the Implementation Schedule column of the table is for STPNOC tracking purposes and is not part of the amended LRA.

Table A4-1 License Renewal Commitments Item #

Comitment LR implementatin Section Schedule 13 Enhance the Buried Piping and Tanks !npection program plant specifications to:

B2.1.18 Start implementation during the 10 years Lower coated piping carefully into a trench to avoid external coating damage.

prior to the period of Use proper storage and handling practices to prevent damage to pipe coating prior to extended operation.

installation. These practices include padded storage, use of proper slings for installation Inspections to be and ultraviolet light resistant topcoats.

complete no later Over excavate trenches and use qualified backfill for bedding piping. Take care during than six months prior backfilling to prevent rocks and debris from striking and damaging the pipe coating.

to the PEO or the end Include the coating used for copper alloy buried piping in the coating database. The of the last refueling coating system must be in accordance with NACE SP0169-2007, and will be used for outage prior to the repair or for new coatings of the buried copper alloy piping in the essential cooling water PEO, whichever system.

occurs later.

" Coat the portion of the essential cooling water system copper alloy piping directly CR 10-23268.

embedded in backfill or directly encased in concrete, extending the coating 2 feet or more above grade.

Enhance the Buried Piping and Tanks Inspection program procedures to:

Consider backfill located within 6 inches of the pipe, and consistent with ASTM D 448-08 size number 67, acceptable. Backfill quality is determined through examination during the inspections conducted by the program. Backfill that does not meet the ASTM criteria, during the initial and subsequent inspections of the program, is considered acceptable if the inspections of buried piping do not reveal evidence of mechanical damage to the pipe coatings due to the backfill.

Ensure the cathodic protection system survey is performed annually.

NOC-AE-14003149 Page 2 of 6 Table A4-1 License Renewal Commitments Item#

Commitment LRA piementation S.Section Schedule

  • V

.NV.

Monitor the output of the cathodic protection system rectifiers every 2 months. The measured current at each rectifier is recorded and compared against a target value.

Following the completion of the plant yard cathodic protection system annual survey, record the current of the rectifier used to achieve an acceptable pipe/soil potential.

That current will be the target current for the rectifier until the next annual survey. If the current measured at the rectifier during the bimonthly monitoring deviates significantly from the target value, a condition report should be created. The rectifier current should be adjusted to an acceptable value. The results of the survey will be documented and trended to identify degrading conditions. When degraded rectifier performance is identified, documentation is required in accordance with the corrective action program.

The system should not be operated outside of established acceptable limits for longer than 90 days.

Recommend increased monitoring of the cathodic protection system and/or additional inspections if adverse indications are discovered during the monitoring of the cathodic protection system.

Evaluate the effectiveness of isolating fittings, continuity bonds and casing isolation, during the plant yard cathodic protection system annual survey. This may be accomplished through electrical measurements.

The personnel performing the Plant yard cathodic protection system annual survey must be NACE-certified, certified by a site-approved trainincq procedure consistent with the NACE requirements, or supervised by a NACE-certified inspector.

Visually inspect buried piping and, if significant indications of degradation are observed, the visual inspections are supplemented by surface and/or volumetric non-destructive testing.

Define the inspection interval for the program directed inspections as every 10 years, beginning the 10 year interval prior to the period of extended operation.

Select the buried and underground piping inspection locations based on risk, considering susceptibility to degradation and consequences of failure.

The risk rankincq for underground pipingq should consider characteristics such as coating type, coating condition, exact external environment, pipe contents, pipe function, and flow characteristics within the pipe.

NOC-AE-14003149 Page 3 of 6 Table A4-1 License Renewal Commitments Item #

Commitment LRA Implementation

~

...Se*

ction.

Schedule ::...

The risk rankinq should generally give piping systems that are backfilled usingq compacted aggregate a higher inspection priority than comparable systems that are completely backfilled using controlled low strength material.

External Corrosion Direct Assessment, as described in NACE Standard Practice SP0502-2010, will be considered for use in identifying inspection locations.

Credit opportunistic examinations of non-leaking pipes toward required examinations, only if they meet the risk ranking selection criteria.

Guided wave ultrasonic, or other advanced inspection techniques should be used, if practical, for the purpose of determining piping locations that should be inspected.

These inspections may not be used as substitutes for inspections required by the program.

Credit an inspection of piping shared between Units 1 and 2 toward the required inspections Of GnIy one '-A.

Examine any piping, valves and closure bolting exposed during inspections.

Examine bolting for loss of material and loose or missing fasteners.

Include two alternatives to directed inspections of the buried or underground piping that is safety-related, hazmat or both. The first alternative is to hydrostatically test 25 percent of the subject piping to 110 percent of the design pressure of any component within the boundary with test pressure being held for eight hours on an interval not to exceed 5 years. The second is an internal inspection of 25 percent of the subject piping by a method capable of accurately determining pipe wall thickness on an interval of every 10 years.

Flow testing of the fire mains, as described in NFPA 25, 2011 Edition, to detect degradation of the buried pipe in lieu of visual inspections of the fire protection system buried and underground piping.

Define "hazm. t pipe" a6 pipe that, during no.rmal o*pcatio, contain*

fluids that, i released, would-be dtiealto the enVironment.

Specify that each inspection will examine either the entire length of a run of pipe, or a minimum of 10 feet. If the entire run of pipe of that material type is less than 10 feet in total length, then the entire run of pipe should be inspected. The inspection consists of a 100 percent visual inspection of the exposed pipe.

NOC-AE-14003149 Page 4 of 6 Table A4-1 License Renewal Commitments tem#

'commitment L**

Implementation Section Schedule Specify that Category C inspections be used when the external cathodic protection system for buried steel or copper alloy pipe meets the acceptance criteria. Category C inspections are 0.5 percent Not-to-Exceed (NTE) two inspections of that piping per inspection period performed.

Specify that Category E inspections be used when the cathodic protection system has been installed but the portions of the piping covered by that system fail to meet the acceptance criteria. Category E inspections are 5 percent, NTE 10 inspections, in years 30 to 40: 6 percent, NTE 15 inspections, in years 40 to 50: and 7.5 percent, NTE 18 inspections, in years 50 to 60. The following condition must be present.

o Coatings and backfill are provided in accordance with STP backfill specification.

o There have been no leaks in buried piping due to external corrosion and no significant coating degradation or metal loss in more than 10 percent of inspections conducted.

o Soil has been demonstrated to be not corrosive for the material type.

Specify that inspection scope for piping that does not meet Category C or E inspection schedule requirements is 10 percent, NTE 23 inspections, in years 30 to 40: 12 percent, NTE 30 inspections, in years 40 to 50; and 15 percent, NTE 38 inspections, in years 50 to 60.

Specify that the AF system underground stainless steel piping located in a vault will undergo two inspections each 10-year inspection period.

Specify that the OW system underground piping will undergo 2% NTE 4 inspection each 10-year inspection period.

Include acceptance criteria for the cathodic protection to be operational (available) at least 85 percent of the time since either 10 years prior to the period of extended operation or since installation or refurbishment, whichever is shorter.

Include acceptance criteria for the cathodic protection system to provide protection for buried piping at least 80 percent of the time since either 10 years prior to the period of extended operation or since installation or refurbishment, whichever is shorter.

  • - Include examples of adverse indicationsdiscovered during piping inspections.

Repair or replacement of the affected component when adverse indications failing to meet the acceptance criteria described in the proqram are discovered.

NOC-AE-14003149 Page 5 of 6 Table A4-1 License Renewal Commitments Item #

Commitment LRA imple

.nt.tion

~~4
  • R mpeentatin Sectibn Schedule

" Indicate that an analysis may be conducted to dcterMine the potential extent of the degradation, A-hen it is observed.

Double inspection sample sizes within the affected piping categories, when adverse indications are detected during inspection of safety related or hazmat bu-rid pipjnge. If adverse indications are found in the expanded sample, an analysis is conducted to determine the extent of condition and extent of cause. The size of the follow-on inspections will be determined based on the extent of condition and extent of cause.

The timing of the additional examinations should be based on the severity of the degradation identified and should be commensurate with the consequences of a leak or loss of function, but in all cases, the expanded sample inspections should be completed within the 10-year interval in which the original adverse condition was identified. the i-lnspcteon sample ize,

again doubled. This doubling of the i..pctio, sampe siZe continues until no more adverse conditions are found. If adverse conditions are extensive, inspections may be halted in an area of concern that is planned for replacement, provided continued operation does not pose a significant hazard. Expansion of sample size may be limited to the piping subject to the observed degradation mechanism.

Definc the scope Of inspection for buried piping using the criteria in NUREG 1801.

The sco)pe Of inspection Will beP bhased_(_ on the condition Of cathodic protection, backfl and coating of the piping. Ensure the Scope of inspection incre.ses the cho-,d-ich,-

protection system does not meet operability requirements, or when backfill is examined and does not meet the backfill acceptance criteria.

-- Examine at least 10 feet Of piping during each inspection of buriedgind I--.if the entire length piping is less than 10 feet, inspect the entiro longth; Of piping.

Indica_;te that the inspections may be l1imited-to 10 percent of the piping under consideration, per inspection *Rtepval, regardless of the inspection scope prescribedi the NUREG 1801 guidance-.

Po-.fo-rm one inspectionA of all1 buried stainless steel safety related piping per npeto 0 nte~Lak.

Exam~ine at least 10 feet Of piping during each inspection Of underground pipfing. if the entire lenath of aiainco is less than 10 feet. iRnsact the en.tfire-IPenth.

I NOC-AE-1 4003149 Page 6 of 6 Table A4-1 License Renewal Commitments Item,#

Commitment

.RA

Ii...

L Implementation

,*x,..

',*S e ctio n ',-...

S c h e~d u le..

...npec th, und.

rgroud stainl*eG steel pipe in the auxiliary feedWat...* Stem. once each inspection inter~al.

Observe for brittle failure at flanges, connections, and joints due to frost heaving, soil stresses, or ground water effects during inspection of buried piping.

Require trendinq cathodic protection system annual surveys results.

Where wall thickness measurements are conducted, the results should be trended if follow-up examinations are conducted.

Specify that the cathodic protection system pine-to-soil potential when usinq a saturated copper/copper sulfate reference electrode must be between -850 mV instant off and -1200 mV.

Indicate that for coated piping, there should be no evidence of coating degradation. If coating degradation is present, it may be considered acceptable if it is determined to be insignificant by an individual possessing a NACE Coating Inspector Program Level 2 or 3 inspector qualification, or an individual has attended the Electric Power Research Institute (EPRI) Comprehensive Coatingqs Course and completed the EPRI Buried Pipe Condition Assessment and Repair Training Computer Based Training Courseoperat.r qualification, Or other-wi-se meeting the qualifications to evaluate coatings as described in 40 CFR 102 and 105.

Specify where damage to the coating has been evaluated as significant and the dama-qe was caused by non-conforming backfill, an extent of condition evaluation should be conducted to ensure that the as-left condition of backfill in the vicinity of observed damage will not lead to further degradation.

Specify that backfill is acceptable if it is consistent with SP0169-2007 Section 5.2.3.

Backfill that'is located within 6 inches of steel pipe that meets ASTM D 448-08 size number 67 is consistent with the objectives of SP0169-2007.

Indicate that for any hydrostatic tests credited by the program, the condition acceptance criteria is no visible indications of leakagqe and no drop in pressure within the isolated portion of the piping that is not accounted for by a temperature change in the test media or quantified leakage across test boundary valves."without leakage" may be met by G

EPA... Nn 1.ra....tng na"*. the test pressure eas noA cange SgiGcaRy uin t"est.

[.