Category:License-Operator
MONTHYEARML23285A2342023-10-13013 October 2023 Confirmation of Initial License Examination RS-23-077, Response to NRC Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations2023-06-16016 June 2023 Response to NRC Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations ML23160A1712023-06-0909 June 2023 Form 5.1-1 Post Examination Check Sheet ML23160A1672023-05-18018 May 2023 Form 1.3-1 Post Examination Security Agreement ML23160A1702023-05-18018 May 2023 Form 2.1-1 Examination Prep Checklist SVPLTR 23-0019, ILT 22-1 (2023-301) Svpltr 23-0019 Post-Exam Submittal Letter (1)2023-05-0101 May 2023 ILT 22-1 (2023-301) Svpltr 23-0019 Post-Exam Submittal Letter (1) ML23087A0482023-03-28028 March 2023 Operator Licensing Examination Approval - Dresden Nuclear Power Station, April 2023 ML23160A1832023-03-16016 March 2023 3.4-1 Events and Evolutions Checklist ML23160A1802023-03-16016 March 2023 2.3-1 Examination Outline Quality Checklist ML23160A0542023-03-16016 March 2023 2.3-2 - Operating Test Quality Checklist SVPLTR 23-0002, 2.3-4 - Written Examination Quality Checklist2023-03-16016 March 2023 2.3-4 - Written Examination Quality Checklist ML23160A1782023-03-0606 March 2023 ILT Exam Outline Submittal Letter ML23160A0522023-01-25025 January 2023 ILT Exam Submittal Letter RS-22-045, Constellation Energy Generation, LLC, Response to NRC Regulatory Issue Summary 2022-01, Preparation and Scheduling of Operator Licensing Examinations2022-03-25025 March 2022 Constellation Energy Generation, LLC, Response to NRC Regulatory Issue Summary 2022-01, Preparation and Scheduling of Operator Licensing Examinations IR 05000237/20213022021-12-29029 December 2021 NRC Initial License Examination Report 05000237/2021302; 05000249/2021302 ML22195A1342021-12-0303 December 2021 Nov 2021 Ile ES-403-1-Written Exam Grading Quality Checklist-Signed ML22195A1312021-12-0303 December 2021 Nov 2021 Ile ES-201-3 - Exam Security Agreement ML22195A1272021-12-0303 December 2021 Nov 2021 Ile ES-201-1 Exam Prep Checklist ML22195A1352021-11-15015 November 2021 Nov 2021 Ile Post-Exam Package Submittal Letter 11/15/2021 ML21287A0442021-10-18018 October 2021 Operator Licensing Examination Approval ML22195A2312021-09-19019 September 2021 Nov 2021 Ile Es 401-6 Written Exam Quality Checklist-Signed ML22195A2282021-09-19019 September 2021 Nov 2021 Ile Es 301-6 Competencies Checklist ML22195A2262021-09-19019 September 2021 Nov 2021 Ile Es 301-4 Simulator Scenario Quality Checklist-Signed ML22195A2222021-09-19019 September 2021 Nov 2021 Ile Es 301-3 Operating Test Quality Checklist-Signed ML22195A2372021-09-0707 September 2021 Nov 2021 Ile Written Exam Submittal Letter 09-07-2021 ML22195A2342021-08-16016 August 2021 Nov 2021 Ile Operating Test Submittal Letter 08-16-2021 ML22195A2662021-06-26026 June 2021 Nov 2021 Ile Es 301-5 Transients and Events Checklist ML22195A2632021-06-26026 June 2021 Nov 2021 Ile Es 201-2 Outline Quality Checklist ML22195A2672021-06-0404 June 2021 Nov 2021 Ile Es 201-2 Outlines Submittal Email ML21139A2372021-05-21021 May 2021 Confirmation of Initial License Examination ML22215A1812021-05-14014 May 2021 April 2021 Administered JPMs ML22236A3332021-05-14014 May 2021 Initial License Exam Forms ES-201-3 ML22236A3322021-05-14014 May 2021 Initial License Exam Form ES-403-1 ML22236A3302021-05-14014 May 2021 Initial License Exam Form ES-201-1 ML22236A3842021-05-14014 May 2021 Initial License Exam Letter 21-0029 ML22235A7572021-05-14014 May 2021 April 2021 Form ES-201-2 Written Outline Only ML22235A7562021-05-14014 May 2021 April 2021 Form ES-301-5 SVPLTR 21-0007, April 2021 Submittal Letter2021-05-14014 May 2021 April 2021 Submittal Letter ML22215A2492021-05-14014 May 2021 April 2021 Form ES-401-6 ML22215A2462021-05-14014 May 2021 April 2021 Form ES-301-6 ML22215A2422021-05-14014 May 2021 April 2021 Form ES-301-4 ML22215A2382021-05-14014 May 2021 April 2021 Form ES-301-3 ML22215A1852021-05-14014 May 2021 April 2021 Administered Scenarios ML22236A0172021-05-14014 May 2021 Initial License Exam Forms ES-301-2 ML22236A0162021-05-14014 May 2021 Initial License Exam Forms ES-301-1 ML22216A1872021-05-14014 May 2021 April 2021 Proposed JPMs ML22216A1902021-05-14014 May 2021 April 2021 Proposed Written Exam ML22216A1892021-05-14014 May 2021 April 2021 Proposed Scenarios ML22236A0182021-05-14014 May 2021 Initial License Exam Forms ES-401-1 and ES-401-3 rev1 ML22215A1862021-05-14014 May 2021 April 2021 Administered Written Exam 2023-06-09
[Table view] Category:Part 55 Examination Related Material
MONTHYEARML23285A2342023-10-13013 October 2023 Confirmation of Initial License Examination RS-23-077, Response to NRC Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations2023-06-16016 June 2023 Response to NRC Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations ML23160A1712023-06-0909 June 2023 Form 5.1-1 Post Examination Check Sheet ML23160A1672023-05-18018 May 2023 Form 1.3-1 Post Examination Security Agreement ML23160A1702023-05-18018 May 2023 Form 2.1-1 Examination Prep Checklist SVPLTR 23-0019, ILT 22-1 (2023-301) Svpltr 23-0019 Post-Exam Submittal Letter (1)2023-05-0101 May 2023 ILT 22-1 (2023-301) Svpltr 23-0019 Post-Exam Submittal Letter (1) ML23087A0482023-03-28028 March 2023 Operator Licensing Examination Approval - Dresden Nuclear Power Station, April 2023 ML23160A1832023-03-16016 March 2023 3.4-1 Events and Evolutions Checklist ML23160A1802023-03-16016 March 2023 2.3-1 Examination Outline Quality Checklist SVPLTR 23-0002, 2.3-4 - Written Examination Quality Checklist2023-03-16016 March 2023 2.3-4 - Written Examination Quality Checklist ML23160A0542023-03-16016 March 2023 2.3-2 - Operating Test Quality Checklist ML23160A1782023-03-0606 March 2023 ILT Exam Outline Submittal Letter ML23160A0522023-01-25025 January 2023 ILT Exam Submittal Letter RS-22-045, Constellation Energy Generation, LLC, Response to NRC Regulatory Issue Summary 2022-01, Preparation and Scheduling of Operator Licensing Examinations2022-03-25025 March 2022 Constellation Energy Generation, LLC, Response to NRC Regulatory Issue Summary 2022-01, Preparation and Scheduling of Operator Licensing Examinations IR 05000237/20213022021-12-29029 December 2021 NRC Initial License Examination Report 05000237/2021302; 05000249/2021302 ML22195A1272021-12-0303 December 2021 Nov 2021 Ile ES-201-1 Exam Prep Checklist ML22195A1312021-12-0303 December 2021 Nov 2021 Ile ES-201-3 - Exam Security Agreement ML22195A1342021-12-0303 December 2021 Nov 2021 Ile ES-403-1-Written Exam Grading Quality Checklist-Signed ML22195A1352021-11-15015 November 2021 Nov 2021 Ile Post-Exam Package Submittal Letter 11/15/2021 ML21287A0442021-10-18018 October 2021 Operator Licensing Examination Approval ML22195A2312021-09-19019 September 2021 Nov 2021 Ile Es 401-6 Written Exam Quality Checklist-Signed ML22195A2282021-09-19019 September 2021 Nov 2021 Ile Es 301-6 Competencies Checklist ML22195A2262021-09-19019 September 2021 Nov 2021 Ile Es 301-4 Simulator Scenario Quality Checklist-Signed ML22195A2222021-09-19019 September 2021 Nov 2021 Ile Es 301-3 Operating Test Quality Checklist-Signed ML22195A2372021-09-0707 September 2021 Nov 2021 Ile Written Exam Submittal Letter 09-07-2021 ML22195A2342021-08-16016 August 2021 Nov 2021 Ile Operating Test Submittal Letter 08-16-2021 ML22195A2662021-06-26026 June 2021 Nov 2021 Ile Es 301-5 Transients and Events Checklist ML22195A2632021-06-26026 June 2021 Nov 2021 Ile Es 201-2 Outline Quality Checklist ML22195A2672021-06-0404 June 2021 Nov 2021 Ile Es 201-2 Outlines Submittal Email ML21139A2372021-05-21021 May 2021 Confirmation of Initial License Examination ML22236A6382021-05-14014 May 2021 April 2021 Initial License Exam Form ES-401-4 ML22215A1812021-05-14014 May 2021 April 2021 Administered JPMs ML22215A1852021-05-14014 May 2021 April 2021 Administered Scenarios ML22236A3332021-05-14014 May 2021 Initial License Exam Forms ES-201-3 ML22236A3322021-05-14014 May 2021 Initial License Exam Form ES-403-1 ML22236A3302021-05-14014 May 2021 Initial License Exam Form ES-201-1 ML22236A3842021-05-14014 May 2021 Initial License Exam Letter 21-0029 ML22235A7572021-05-14014 May 2021 April 2021 Form ES-201-2 Written Outline Only ML22235A7562021-05-14014 May 2021 April 2021 Form ES-301-5 SVPLTR 21-0007, April 2021 Submittal Letter2021-05-14014 May 2021 April 2021 Submittal Letter ML22215A2492021-05-14014 May 2021 April 2021 Form ES-401-6 ML22215A2462021-05-14014 May 2021 April 2021 Form ES-301-6 ML22215A2422021-05-14014 May 2021 April 2021 Form ES-301-4 ML22215A2382021-05-14014 May 2021 April 2021 Form ES-301-3 ML22215A1862021-05-14014 May 2021 April 2021 Administered Written Exam ML22236A6392021-05-14014 May 2021 April 2021 Initial License Exam Form ES-401-9 ML22236A0202021-05-14014 May 2021 Initial License Exam Forms ES-D1 ML22236A6372021-05-14014 May 2021 April 2021 Initial License Exam Form ES-301-7 ML22236A6402021-05-14014 May 2021 April 2021 Initial License Exam Operating Test Outline Comments 2023-06-09
[Table view] |
Text
2013 DRESDEN NUCLEAR POWER STATION INITIAL LICENSE EXAMINATION OUTLINE SUBMITTAL
ES-201 Examination Outline Quality Checklist Form ES-201-2 Facility: Date of Examination:
Initials Item Task Description a b* c#
1.
w
- a. Verify that the outiine(s) fit(s) the appropriate model, in accordance with ES-401 or ES-401 N.
~ fJ~ R\fvJ R b. Assess whether the outline was systematically and randomly prepared in accordance with T
I Section D.1 of ES-401 or ES-401 N and whether all KIA categories are appropriately sampled. ~ tt\4 R~\.l T
E
- c. Assess whether the outline over-emphasizes any systems, evolutions, or generic topics. ~ t.Jifr ~\(\J N
- d. Assess whether the justifications for deselected or rejected KIA statements are appropriate. tJ\A R\{\d
- 2. a. Using Form ES-301-5, verify that the proposed scenario sets cover the required number of """' N\~
normal evolutions, instrument and component failures, technical specifications, and major
~ R~W s transients.
I M b. Assess whether there are enough scenario sets (and spares) to test the projected number and u mix of applicants in accordance with the expected crew composition and rotation schedule ~~A g~\J without compromising exam integrity, and ensure that each applicant can be tested using at L
A least one new or significantly modified scenario, that no scenarios are duplicated from the ~
T applicants' audit test(s), and that scenarios will not be repeated on subsequent days.
0 R
- c. To the extent possible, assess whether the outline(s) conform(s) with the qualitative and quantitative criteria specified on Form ES-301-4 and described in Appendix D.
~ ~\A RK\J
- 3. a. Verify that the systems walk-through outline meets the criteria specified on Fonm ES-301-2:
(1) the outline(s) contain(s) the required number of control room and in-plant tasks distributed w among the safety functions as specified on the fonm
~Y\1 A (2) task repetition from the last two NRC examinations is within the limits specified on the fonm ~\i L (3) no tasks are duplicated from the applicants' audit test(s) ~
K (4) the number of new or modified tasks meets or exceeds the minimums specified on the fonm (5) the number of alternate path, low-power, emergency, and RCA tasks meet the criteria on T the form.
H R b. Verify that the administrative outline meets the criteria specified on Form ES-301-1:
0 (1) the tasks are distributed among the topics as specified on the fonm J.w. ~v.. i<V\J u (2) at least one task is new or significantly modified G (3) no more than one task is repeated from the last two NRC licensing examinations H '
- c. Determine if there are enough different outlines to test the projected number and mix of applicants and ensure that no items are duplicated on subsequent days. ~ rv\~ ~\J
- 4. a. Assess whether plant-specific priorities (including PRA and IPE insights) are covered in the appropriate exam sections. ~ t.~\A W\J G
E N
- b. Assess whether the 10 CFR 55.41/43 and 55.45 sampling is appropriate. rNA ~'\A w:w E
- c. Ensure that KIA importance ratings (except for plant-specific priorities) are at least 2.5. 1.. rv\A fN..w R
A
- d. Check for duplication and overlap among exam sections. ~ 111\A ~\.t}
L e. Check the entire exam for balance of coverage. J,\\\ N\A @(\J
- f. Assess whether the exam fits the appropriate job level (RO or SRO). ~ N\A P)(lJ
- a. Author Jtat2. MeJJ:.ttr~d .Nft~ZZQI,
- b. Facility Reviewer(*) .d/1# 7 /) AI/A
- c. NRC Chief Examiner (#) ~Ot>JO 'lbt11A W!tiA~IK~Y.~1. Jb- zh!zolf
..,._ .L J~&J*Ht:o** ~.\ .....~.-L~ ":'f/L ::"\
- d. NRC Supervisor I / lY " .:¢;p-¥ Note: #Independent NRC reviewer initial items in Column "c"; chief examiner concurrence required.
- Not applicable for NRC-prepared examination outlines.
ES-201, Page 26 of 28
Scenario Outline Station: Dresden Generating Station Scenario No.: ILT-N-1 Class ID: 2013-301 Evaluators Operators I crew position I ATC I BOP I CRS Initial Conditions: -5% Power, steadl£ state, and eguilibrium xenon Turnover: 2C RFP OOS Event Malt. Event Event No. No. Type* Description N BOP Establish Primary Containment lnerting Lineup Per DOP 1 NONE 1600-05 2 NONE R ATC Withdraw Rods To Open Turbine Bypass Valves 3 RODH08DO CIT ATC Control Rod Drifts Out (TS) 4 NIA5POT liT BOP APRM Fails Upscale Without Half Scram (TS) 5 X10/X13 c ATC RFP Vent Fan- Trips Due To Overcurrent 6 HPINIT 1/T BOP HPCI System Spurious Initiation (TS) 7 F41 M TEAM LOCA In DW- Manual Scram 8 H32 c TEAM Loss Of RFPs- Use HPCI To Restore Level
- (N)ormal, (R)eact1v1ty, (l)nstrument, (C)omponent, (M)aJor, (T)ech Spec SCENARIO ILT-N-1 Page 2 of 28 Rev. 00 (08/13)
Scenario Outline Station: Dresden Generating Station Scenario No.: ILT-N-2 Class ID: 2013-301 Evaluators Operators I crew position I ATC I BOP I CRS Initial Conditions: 100% Power1 steadl£ state 1 and eguilibrium xenon Turnover: At beginning of shift1 ~erform Core S~ral£ Test Dro~ ~ower using control rods Event Mal f. Event Event No. No. Type* Description CORE SPRAY TEST per DOS 1400-05 with Min Flow Auto-1 AT17 CIT BOP close Failure (TS) 2 NONE R ATC Lower Power Using Control Rods 3 RODD08ST c ATC CRD- Control Rod Stuck & Requires Higher Pressure to Move 4 NONE T SRO Torus Level PAM Instrument Not Qualified per IMD (TS) 5 Q31 I Q21 c BOP Service Water Pump Degradation 6 RLMRFPA(B)(C) I ATC FW- Recirc Runback Due to Loss of FW Signal RXMLGOSC I 7 M ALL Manual Scram REQUIRED - Due to Reactor Core Instabilities A 55 RDHLVFPA(B) I 8 MIC ALL Failure to Scram (SBLC successful)
RDHLDEGA(B)
- (N)ormal, (R)eactlvlty, (l)nstrument, (C)omponent, (M)aJor, (T)ech Spec SCENARIO ILT-N-2 Page 2 of28 Rev. 00 (08113)
Scenario Outline Station: Dresden Generating Station Scenario No.: ILT-N-3 Class ID: 2013-301 Evaluators Operators I crew position I ATC I BOP I CRS Initial Conditions: 88% Power, stead~ state, and eguilibrium xenon Turnover: Scheduled load droe at beginning of shift Surveillance DOS 0500-01 Manual Scram Circuit Sensor Test due Event Malf. Event Event No. No. Type* Description 1 NONE R ATC Lower Power with Recirc 2 MGDDBATR c BOP Generator Bus Duct Blower Trip 3 NONE N ATC Perform Manual Scram Circuit Sensor Test on RPS Channel B 4 ICTUBLK liT BOP Isolation Condenser Tube Leak (TS) 5 B02 CIT ATC RPS - MG Set Trips I Re-energize from Reserve Power (TS) 6 B02 I ATC Recirc MG Set Vent Fan Failure 7 T50 I T52 M ALL Loss of Stator Cooling I Manual Scram AT5 NVM100BP FLOODING- Loss of RPV Level Indication Due to Loss of lnst 8 NVML29AP M ALL Power and Transmitter Failures NVML29BP NVML 112P
- (N)ormal, (R)eact1v1ty, (l)nstrument, (C)omponent, (M)aJor, (T)ech Spec SCENARIO ILT-N-3 Page 2 of26 Rev. 00 (08113)