ML13182A015

From kanterella
Jump to navigation Jump to search
Third 10-Year Interval, Second Period: Owner'S Activity Report Number U1R17
ML13182A015
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 06/26/2013
From:
APS, Arizona Public Service Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
102-06718-TNW/RKR/CJS
Download: ML13182A015 (5)


Text

10 CFR 50.55a Oaps Palo Verde Nuclear Generating Station P.O. Box 52034 102-06718-TNW/RKR/CJS Phoenix, AZ 85072 June 26, 2013 Mail Station 7636 Tel: (623) 393-5764 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Dear Sirs:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Unit 1, Docket No. STN 50-528 Third 10-Year Interval, Second Period:

Owner's Activity Report Number UlR17 Pursuant to 10 CFR 50.55a and in accordance with the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Case N-532-4, Arizona Public Service Company (APS) hereby submits the Owner's Activity Report (Form OAR-i) for Unit 1 refueling outage 17 (U1R17). The outage ended on April 28, 2013.

No commitments are being made to the NRC by this letter. Should you need further information regarding this submittal, please contact Robert K. Roehler, Licensing Section Leader, at (623)393-5241.

Sincerely, W64 4K'I TNW/RKR/CJS/hsc

Enclosure:

Unit 1 Seventeenth Refueling Outage Owner's Activity Report, Report U1R17 cc: A.T. Howell III NRC Region IV Regional Administrator J. K. Rankin NRC NRR Project Manager for PVNGS (electronic)

M. A. Brown NRC Senior Resident Inspector for PVNGS A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway Comanche Peak 0 Diablo Canyon 0 Palo Verde 0 San Onofre 0 South Texas 0 Wolf Creek Aag-4

ENCLOSURE Unit 1 Seventeenth Refueling Outage Owner's Activity Report Report U1R17

FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number: IR17 Plant: Palo Verde Nuclear Generating Station, 5801 S. Wlntersburg Road, Tonopah, Arizona 85354-7529 Unit No.: I Commercial service date: Jan 28, 1986 Refueling Outage No.: 17 (ifapphtatft)

Current inspection interval ISI*, RR* and Pressure Test* = 3rd Interval, [WE* & IWI = 2nd Interval e,,.Ps.4T. mE

",and ISI, RR, Pressure Test and IWE = 2nd Period, IWL I1st Period Current Inspection period_

Y3)

(1'.2*

Edition and Addenda of Section Xl applicable to the inspection plans = 2001 Ed. 2003 Ad., IWL = 2007 Ed. 2008 Ad Date and revision of inspection plans ISI--9/14/11, R 1. Press Test=7/20112, R 3, IWE=4I02I09, R 0, IWL = 11/08112 R 1 Edition and Addenda of Section Xl applicable to repair/replacement activities, if different than the inspection plans 2001 Edition through 2003 Addenda Code Cases used: N-532-4 (ifBppac")

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made In this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI; and (c) the repairlreplacement activities and evaluations supporting the completion of 1R17 conform to the requirements of Section XI.

(refuewl outage nuhber)

Folley, Roy Digitally signed by Foley. Roy C(Z07131)

ON: cn-Fle. Roy c(z07131)

Renson: I am Vmeaudhor of tIs docaumitn Date: 2013.06.19 08:37:01-07G'W SignedC(Z07131) Date: Jun 19. 2013 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province. of Arizona and employed by HSB Global Standards of Hartford. Connecticut have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XA.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

OlgMaly ligne by Hagamni.

Hogstrom, RobY )

DM:cn=-HogsoM* Rabet Robert (YH2450) (Y24W)

Dale. 2013.06.19 08:3M38.07'0 Commissions N.B. 9685, Az 264. "A, N, 1,C" nvpectaft ,gnatutr) Naftnal Board. Slate. Province. and Endorsements Date: Jun 19,2013 PV-E0796 Ver. I

Palo Verde Nuclear Generating Station Table I Items with flaws or relevant conditions that required evaluation for continued service I Excamination [tern Descdptlon IEvaluation I Category INumber of Work IDescription

...... ~None ...

5/23/2013 2

Palo Verde Nuclear Generating Station Table 2 Abstract of repair/replacement activities required for continued service Code Class Item Des lpon Date Repalr/Replaiement 2 1PSGELD08 -Feedwater Header to SGl RCE-E01A Downcomer CS pe spool with SS per EDC 200.00038 4/252013 WON 3124943 2 1PSGELOOB -Feedwater Header to SGI RCE-EOI/ Downcomer ReplaceC pipe spool with p er EDC 2008400037 4/2512013 WON 3124945 3 1PSPBL032 - ESP Pump to DG Heat Exchang er DGB-EO1 Replace spool due to corrosion 4/16/2013 WON 3463890 3 1PSPBL.O49 S005 - DGBE01 HX to Spray Pond'"B Replace p due to Internal corrosion 4/20/2013 WON 3467077 3 IMEWBE0I - Essential Cooling Water Heat Exchanger " Perform Base Metal Repairs 4/18/2013 WO# 3599932 3 iMOGAE04 - Lube Oi Cooler Weld repair coroded areas on divider plate 3/2/2013 WOO 3909135 3 IMDGAEOIA- DG AAir Intercooter A Weld repai upper waterbox of lntercooier 3/2/2013 WON 3915866 3 1MDGAEO5 -JACKET WATER COOLER Weld repair corroded areas 0n divider plate 3/2/2013 WO# 3987014 2 IPSGEV005 - SIG #2 Economizer Feed Header Check Valve Add counter weht ito disclrernove web cracks 41,2/2013 WO# 4018316 1 1MRCEE01A - SG1 hot log Installwestinouse mechanical plugs in SG1 hot ta- 4/19/2013 WON 4373261

- IMRCEEO1A

  • SG1 cold leg Install wees house mechanical plugs in SG1 cold Ion 4/19/2013 WOW4373262 1 1MRCEEO1B- SG2 hot eq Install westin ouse mechanical plug in SG2 hot leg 4/19/2013 WON 4373263 1 1MRCEE01B- SG2 cold Install wsWrhose medhanical plu* InSG2 cold 4/19/2013 WOW4373264 3 1P5P5&L030- FP S TO 555 OGHT EXCH OG516WS-EG1 Remove indicatijon from pipe wait 4/8/2013 WOW 4378944 3 lPSPLf25- ESS & G HTEXCMDGWGOWE0I TO a SPRAY IN POND Blend identified defeds 4/18/2013 WO# 4381803 6/12/2013