Nuclear Operating Company South Texas Pro/ecl Electric Generating Station PO. Box 289 Wadsworth. Texas 77483

-%A/V__--

January 21 2013 NOC-AE-13002945 10 CFR 54 STI: 33642248 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 South Texas Project Units 1 and 2 Docket Nos. STN 50-498, STN 50-499 Update to License Renewal Application - Environmental Permits (TAC Nos. ME5122, ME5123, ME4938 and ME4939)

Reference:

STPNOC letter dated October 25, 2010, from G. T. Powell to NRC Document Control Desk, "License Renewal Application" (NOC-AE-10002607) (ML103010256)

By the referenced letter, STP Nuclear Operating Company submitted a License Renewal Application (LRA) including an Environmental Report (ER) for South Texas Project (STP), Units 1 and 2. The enclosure to this letter provides an update to Table 9.1-1, "Environmental Authorizations for Current STP Units 1 & 2 Operations," of the ER in a line-in/line-out format.

There are no regulatory commitments in this letter.

Should you have any questions regarding this letter, please contact either Arden Aldridge, STP License Renewal Project Lead, at (361) 972-8243 or Ken Taplett, STP License Renewal Project regulatory point-of-contact, at (361) 972-8416.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on 1 /;51h-OL3 Date D. W. Rencurrel Senior Vice President kjt

Enclosure:

Table 9.1-1, "Environmental Authorizations for Current STP Units 1 & 2 Operations"

NOC-AE-13002945 Page 2 cc:

(paper copy)

(electronic copy)

Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, Texas 76011-4511 Balwant K. Singal Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 8B13) 11555 Rockville Pike Rockville, MD 20852 Senior Resident Inspector U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN1 16 Wadsworth, TX 77483 C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 John W. Daily License Renewal Project Manager (Safety)

U.S. Nuclear Regulatory Commission One White Flint North (MS 011-Fl)

Washington, DC 20555-0001 Tam Tran License Renewal Project Manager (Environmental)

U. S. Nuclear Regulatory Commission One White Flint North (MS 011 F01)

Washington, DC 20555-0001 A. H. Gutterman, Esquire Kathryn M. Sutton, Esquire Morgan, Lewis & Bockius, LLP John Ragan Chris O'Hara Jim von Suskil NRG South Texas LP Kevin Polio Richard Pena City Public Service Peter Nemeth Crain Caton & James, P.C.

C. Mele City of Austin Richard A. Ratliff Alice Rogers Texas Department of State Health Services Balwant K. Singal John W. Daily Tam Tran U. S. Nuclear Regulatory Commission

Enclosure NOC-AE-1 3002945 Page 1 of 3 Table 9.1-1 Environmental Authorizations for Current STP Units 1 & 2 Operations Issue or Expiration Agency Authority Requirement Number Date Activity Covered Federal and State Requirements U.S. Nuclear Atomic Energy Act License to operate NPF-76 Issued: 03/22/1988 Operation of STP Unit 1 Regulatory (42 USC 2011, et Expires: 08/20/2027 Commission seq.), 10 CFR 50.10 U.S. Nuclear Atomic Energy Act License to operate NPF-80 Issued: 12/16/1988 Operation of STP Unit 2 Regulatory (42 USC 2011, et Expires: 12/15/2028 Commission seq.), 10 CFR 50.10 U.S. Department of 49 USC 5108 Registration 0621!0550 Issued: 06/21/2010 Hazardous materials Transportation 067S 06/04/2012 shipments 060412551074U Expires: 0gi3=/214 06/30/2013 U.S. Army Corps of Section 10 of the Permit for maintenance Permit No. 10570 Issued: 11/04/2004 Maintenance dredging Engineers Rivers and Harbors dredging (USACE)

Expires: 12/31/2014 of barge slip Act of 1899 U.S. Army Corps of Section 10 of the Permit for maintenance Permit No.

Issued: 07/21/09 Maintenance dredging Engineers Rivers and Harbors dredging SWG-1992-02707 Expires: 12/31/2019 of intake Act of 1899 Texas Commission on Clean Water Act TPDES Permit WQ0001908000 Issued: 07/2-/2005 Treat wastewater and Environmental Quality (33 USC Section 1251 TX0064947 04/05/2012 discharge to Colorado et seq.) Texas Expires: 12101/2009 River from Main Administrative Code 12/01/2014 Cooling Reservoir (TAC) (30 TAC 305)

Draft p.rmit has be.

izucd, and sci the public notice period. If approved, theeprt date *AhII ba 1201/201.4 Texas Commission on 30 TAC 116 Air Permit Permit No. 7410 Issued: 12/23/2004 Air permit for auxiliary Environmental Quality Expires: 12/23/2014 boilers and voiding of a PSD permit, PSD-TX-209M1

Enclosure NOC-AE-1 3002945 Page 2 of 3 Issue or Expiration Agency Authority Requirement Number Date Activity Covered Federal and State Requirements Texas Commission on 30 TAC 122 Federal Operating Air Permit No. GO-Issued: 025/2006 Air permit for various Environmental Quality Permit 801 01/18/2011 emission sources Expires: 0!/25/201!

01/18/2016 Texas Commission on Clean Water Act Storm Water Multi-Permit No.

Issued: 11/02/2011 Storm water dischar-qe Environmental Quality (33 USC Section 1251 Sector General Permit-TXR05P472 Expires: 08/14/2016 for the facility et seg.) (30 TAC 305)

Industrial Texas Commission on 30 TAC 335 Registration of Solid Waste Issued: 08/16/1976 Registration of Environmental Quality Industrial and Registration No:

Expires: NA, industrial and Hazardous Waste 30651, EPA ID:

registration must be hazardous waste TXD020810503 amended upon generation and changes in waste management including profile or activities onsite disposal of Class III industrial solid waste Texas Commission on 30 TAC 290 Potable Water System TCEQ ID No.

Issued: NA Operation of public Environmental Quality 1610103/1610051 Expires: NA potable water system(s)

Both systems are designated as active Texas Wate Texas Water Code Certificate of 14-5437A Issued: 03/17/2009 Water rights for Commission on Sections 11.085 and Adjudication Expires: NA diversion and Environmental Quality 11.122 impoundment of water from Colorado River Texas Commission on Texas Water Code Certificate of 14-5437B Issued: 01/10/2012 Surface Water Environmental Quality Sections 11.085 and Adjudication Expires: NA Diversion Permit -

11.122 Diversion rate from the MCR Texas Commission on Texas Water Code Appropriation of State CP-327A Issued: 08/31/2009 Contractural Permit to Environmental Quality Sections 11.085 and Water Expires: NA appropriate State Water 11.122

Enclosure NOC-AE-1 3002945 Page 3 of 3 Issue or Expiration Agency Authority Requirement Number Date Activity Covered Federal and State Requirements Tennessee Tennessee Code License to ship T-TX-001-Ll3 Issued: 12A&/2009 Shipments of Department of Annotated 68-202-206 radioactive material 01/01/2013 radioactive nat-e4al Environment and waste Expires: 1121/20!0 waste to processing Conservation 12/31/2013 facilities in Tennessee Utah Department of Utah Rule 313-26 License to ship Permit No.

Issued: 07/2-12010 Shipments of Environmental Quality radioactive material 0606003900 07/21/2012 radioactive material waste Expires: 07/2!/2011 waste to disposal 07/21/2013 facility in Utah Texas Department of Title 25, TAC License to ship W0016 Issued: 06/12/2012 Shipment of radioactive State Health Services

§289.257 radioactive waste Expires: 06/30/2022 waste to Texas LLRW disposal facility Local Requirements Coastal Plains Texas Water Code Authorization for Permit No.

Issued: 02/07/2008 Groundwater Groundwater Chapter 36 groundwater OP-04122805 02/24/2011 withdrawal from five Conservation District withdrawals Expires: 02i28/20!1 wells 02/28/2014 TPDES - Texas Pollutant Discharge Elimination System TAC - Texas Administrative Code LLRW - low level radioactive waste