Other: ML110872079, ML11145A064, ML11256A057, ML11256A058, ML11256A059, ML12011A188, ML12086A081, ML12264A642, ML13029A497, ML13032A074, ML13063A071, ML13198A056, ML13253A163, ML16118A311, NOC-AE-12002780, Clarification of Information in Support of the Review of the License Renewal Application, NOC-AE-13002945, Update to License Renewal Application - Environmental Permits
|
MONTHYEARML1030102572010-10-25025 October 2010 Transmittal of License Renewal Application Project stage: Request ML1108720792011-04-0505 April 2011 Project Manager Change for the License Renewal of South Texas Project, Units 1 and 2 Project stage: Other ML11145A0642011-06-21021 June 2011 Plan for the Environmental Related Regulatory Audit Regarding the South Texas Project, Units 1 and 2, License Renewal Application Review Project stage: Other ML11193A0742011-07-0505 July 2011 Response to Request for Additional Information for the Review of the License Renewal Application Project stage: Response to RAI NOC-AE-11002687, Response to Request for Additional Information for the South Texas Project License Renewal Application2011-07-0505 July 2011 Response to Request for Additional Information for the South Texas Project License Renewal Application Project stage: Response to RAI ML11193A0162011-07-0505 July 2011 Response to Request for Additional Information for the South Texas Project License Renewal Application Project stage: Response to RAI NOC-AE-11002691, Response to Request for Additional Information for the Review of the License Renewal Application2011-07-0505 July 2011 Response to Request for Additional Information for the Review of the License Renewal Application Project stage: Response to RAI ML11201A0622011-08-0404 August 2011 Request for Additional Information for the Review of the South Texas Project, License Renewal Application Project stage: RAI ML1123000162011-08-18018 August 2011 License Renewal - Errata in AMP RAI Package Project stage: RAI ML11214A2072011-08-18018 August 2011 RAI for the Review of the STP, License Renewal Application (TAC No. ME4938 and ME512) Project stage: RAI NOC-AE-11002711, Response to Request for Additional Information for License Renewal Application2011-08-23023 August 2011 Response to Request for Additional Information for License Renewal Application Project stage: Response to RAI ML11250A0672011-08-23023 August 2011 Response to Request for Additional Information for License Renewal Application Project stage: Response to RAI ML11256A0592011-08-31031 August 2011 Documents to Support Review of the South Texas Project License Renewal Application, WR- 11, a Summary of Historic and Current (Past 5 Years) Total Dissolved Solids (Tds) Data for Groundwater Produced by STP Production Wells from the Deep Ch Project stage: Other ML11256A0562011-08-31031 August 2011 Transmittal of Documents to Support Review of the South Texas Project License Renewal Application Project stage: Request ML11256A0582011-08-31031 August 2011 Documents to Support Review of the South Texas Project License Renewal Application, WR-5, TCEQ Id No. 1610103/1610051 (Operation of Public Potable Water System) Project stage: Other ML11256A0572011-08-31031 August 2011 Documents to Support Review of the South Texas Project License Renewal Application, List of Transmitted Documents Including Copy of Each Document, Enclosure to NOC-AE-11002720 Project stage: Other ML1123601142011-09-0101 September 2011 Request for Additional Information for the Review of the South Texas Project License Renewal Application Project stage: RAI ML11255A2112011-09-0606 September 2011 Response to Request for Additional Information for the License Renewal Application Project stage: Response to RAI NOC-AE-11002719, Response to Request for Additional Information for the License Renewal Application2011-09-0606 September 2011 Response to Request for Additional Information for the License Renewal Application Project stage: Response to RAI ML11259A0142011-09-12012 September 2011 Response to Requests for Additional Information for the License Renewal Application Project stage: Response to RAI NOC-AE-11002723, Response to Requests for Additional Information for the License Renewal Application2011-09-12012 September 2011 Response to Requests for Additional Information for the License Renewal Application Project stage: Response to RAI NOC-AE-11002734, Transmittal of Document to Support Review of the License Renewal Application2011-09-12012 September 2011 Transmittal of Document to Support Review of the License Renewal Application Project stage: Request ML11259A0312011-09-12012 September 2011 Transmittal of Document to Support Review of the License Renewal Application Project stage: Request ML11270A0602011-09-22022 September 2011 Response to Requests for Additional Information for License Renewal Application Project stage: Response to RAI ML11269A0022011-09-28028 September 2011 Requests for Additional Information for the Review of the South Texas Project License Renewal Application Project stage: RAI ML11298A0852011-10-18018 October 2011 Response to Requests for Additional Information for License Renewal Application Project stage: Response to RAI NOC-AE-11002761, Clarification to Response to Request for Additional Information for License Renewal Application (TAC No. ME4938 & ME5122)2011-11-17017 November 2011 Clarification to Response to Request for Additional Information for License Renewal Application (TAC No. ME4938 & ME5122) Project stage: Response to RAI ML11333A0942011-11-17017 November 2011 Clarification to Response to Request for Additional Information for License Renewal Application (TAC No. ME4938 & ME5122) Project stage: Supplement ML12011A1882012-01-10010 January 2012 Clarification of Information in Support of the Review of the License Renewal Application Project stage: Other NOC-AE-12002780, Clarification of Information in Support of the Review of the License Renewal Application2012-01-10010 January 2012 Clarification of Information in Support of the Review of the License Renewal Application Project stage: Other NOC-AE-110027, Supplemental Response to Requests for Additional Information for the South Texas Project License Renewal Application - SAMA2012-01-19019 January 2012 Supplemental Response to Requests for Additional Information for the South Texas Project License Renewal Application - SAMA Project stage: Supplement NOC-AE-120027, Clarification to Supplemental Response to Request for Additional Information for the South Texas Project License Renewal Application - SAMA2012-02-16016 February 2012 Clarification to Supplemental Response to Request for Additional Information for the South Texas Project License Renewal Application - SAMA Project stage: Supplement ML12047A2852012-02-29029 February 2012 January 17, 2012, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission & STP Nuclear Operating Company, Concerning Requests for Additional Information Pertaining to the South Texas Project License Renewal Project stage: RAI ML12017A1282012-02-29029 February 2012 RAI for the Review of the STP LRA Project stage: RAI NOC-AE-12002818, Response to Requests for Additional Information for the Review of the South Texas Project License Renewal Application2012-03-12012 March 2012 Response to Requests for Additional Information for the Review of the South Texas Project License Renewal Application Project stage: Response to RAI ML12079A0142012-03-12012 March 2012 Response to Requests for Additional Information for the Review of the South Texas Project License Renewal Application Project stage: Response to RAI ML11290A2262012-03-19019 March 2012 Revision of Schedule for the Conduct of Environmental Review of the South Texas Project License Renewal Application Project stage: Approval ML12128A0612012-05-0404 May 2012 NRR E-mail Capture - NEPA Consultation - Waterborne Outbreak Project stage: Request ML12142A0022012-05-18018 May 2012 NRR E-mail Capture - Environmental Permit Updated Status Project stage: Request ML12171A4832012-08-10010 August 2012 Revision of Schedule for the Conduct of Environmental Review of the South Texas Project License Renewal Application Project stage: Approval ML11153A0822012-11-14014 November 2012 Issuance of Environmental Scoping Summary Report Associated with the Staffs Review of the Application by STP Nuclear Operating Company for Renewal of the Operating License for South Texas Project, Units 1 and 2 Project stage: Approval ML12086A0812012-11-14014 November 2012 Environmental Impact Statement Scoping Process Summary Report for South Texas Project, Units 1 and 2 Project stage: Other ML12264A6422012-11-14014 November 2012 STP Scoping Report_Paula Cooper Project stage: Other ML12324A0492012-11-30030 November 2012 NUREG-1437 Supp 48 Dfc Generic Environmental Impact Statement for License Renewal of Nuclear Plants: Regarding South Texas Project, Units 1 and 2 (Draft for Comment) Project stage: Draft Other ML12339A2652012-12-0505 December 2012 Notice of Availability of the Draft Plant-Specific Supplement 48 to the GEIS for License Renewal of Nuclear Plants Regarding South Texas Project, Units 1 and 2, Project stage: Draft Other ML12195A0852012-12-0505 December 2012 Notice of Availability of the Draft Plant-Specific Supplement 48 to the GEIS for License Renewal of Nuclear Plants Regarding South Texas Project, Units 1 and 2, Project stage: Draft Other ML13029A7552013-01-15015 January 2013 Transcript of South Texas Project License Renewal Public Meeting: Afternoon Session, January 15, 2013, Pages 1-34 Project stage: Meeting ML13029A4972013-01-15015 January 2013 Slides - Preliminary Site-Specific Results of the Environmental Review for South Texas Project License Renewal Project stage: Other NOC-AE-13002945, Update to License Renewal Application - Environmental Permits2013-01-21021 January 2013 Update to License Renewal Application - Environmental Permits Project stage: Other ML13032A0742013-01-21021 January 2013 Update to License Renewal Application - Environmental Permits Project stage: Other 2011-09-06
[Table View] |
Text
Nuclear Operating Company South Texas Pmject Electric Generating Station PO. Box 289 Wadsworth, Texas 77483
-A/vA-July 5, 2011 NOC-AE-1 1002691 10CFR54 STI: 32893021 File: G25 U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2746 South Texas Project Units 1 and 2 Docket Nos. STN 50-498, STN 50-499 Response to Requests for Additional Information for the Review of the South Texas Proiect License Renewal ADDlication (TAC Nos. ME5122) m
Reference:
- 1. STPNOC Letter from G. T. Powell to NRC Document Control Desk, "License Renewal Application", dated October 25, 2010 (NOC-AE-1 0002607) (ML103010257)
- 2. NRC letter, "Request for Additional Information for the Review of the South Texas Project License Renewal Application", dated June 17, 2011 (ML11167A113)
By Reference 1, STP Nuclear Operating Company (STPNOC) submitted the License Renewal Application (LRA) for South Texas Project (STP) Units 1 and 2. By Reference 2, the NRC staff requested additional information for the review of the STP LRA. STPNOC's response to the request for additional information is included in Enclosure 1 to this letter.
There are no regulatory commitments in this letter.
Should you have any questions regarding this letter, please contact either Arden Aldridge, STP License Renewal Project Lead, at (361) 972-8243 or Ken Taplett, STP License Renewal Project regulatory point-of-contact, at (361) 972-8416.
I declare under penalty of perjury that the foregoing is true and correct.
Executed on D3a-te
. Zell Da~e G. T. Powell Vice President, Technical Support & Oversight KJT
Enclosure:
STPNOC Response to Requests for Additional Information 4IA7
NOC-AE-1 1002691 Page 2 cc:
(paper copy)
(electronic copy)
Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 612 East Lamar Blvd, Suite 400 Arlington, Texas 76011-4125 Balwant K. Singal Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 8B1) 11555 Rockville Pike Rockville, MD 20852 Senior Resident Inspector U. S. Nuclear Regulatory Commission P. O. Box 289, Mail Code: MN116 Wadsworth, TX 77483 C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 John W. Daily License Renewal Project Manager (Safety)
U.S. Nuclear Regulatory Commission One White Flint North (MS 011-Fl)
Washington, DC 20555-0001 Tam Tran License Renewal Project Manager (Environmental)
U. S. Nuclear Regulatory Commission One White Flint North (MS 011 F01)
Washington, DC 20555-0001 A. H. Gutterman, Esquire Kathryn M. Sutton, Esquire Morgan, Lewis & Bockius, LLP John Ragan Catherine Callaway Jim von Suskil NRG South Texas LP Ed Alarcon Kevin Polio Richard Pena City Public Service Peter Nemeth Crain Caton & James, P.C.
C. Mele City of Austin Richard A. Ratliff Alice Rogers Texas Department of State Health Services Balwant K. Singal John W. Daily Tam Tran U. S. Nuclear Regulatory Commission
Enclosure NOC-AE-1 1002691 Page 1 STPNOC Response to Requests for Additional Information SOUTH TEXAS PROJECT LICENSE RENEWAL APPLICATION REQUESTS FOR ADDITIONAL INFORMATION REGARDING THE ANALYSIS OF CULTURAL RESOURCE IMPACTED ENVIRONMENT Issue:
The Environmental Report (ER) contains statements referring to missing records of cultural sites, requiring clarification.
Background:
Additional information is needed for the staff review of the cultural resource affected environment associated with license renewal related activities, pursuant to the review criteria in Environmental Standard Review Plan, Supplement 1, Sections (ESRPISIs) 2.2.8 and 4.4.5 and in accordance with the rule (10 CFR 51).
NRC Requested Information:
Provide the following cultural resources information in accordance with information submittal guidelines for cultural resources location information (e.g., exclusion of map details of site locations).
- 1. The ER states that the third site is missing from the records. Describe the process that was used to identify all three sites located at 3.85 and 4.40 miles from the northeast boundary of the South Texas Project (STP) property. Describe what the statement regarding the third site is referring to regarding the missing record.
STPNOC Response:
During the preparation of ER Section 2.14, an error was made in the interpretation and description of the three sites (Sites 41MG48, 41MG49, and 41MG112). The form for the "missing record" site (Site 41 MG49) was stapled to another site's form and was missed.
Corrected and augmented descriptions of the three sites are provided below (distances to the three cultural sites were measured from a spot measured equal distance between Units 1
& 2):
Site 41 MG48 was originally described as a boat wreck in the License Renewal ER.
However, the site form for this site does not mention a boat wreck. The site is located 5.17 miles northeast of the South Texas Project (STP) site and is a late 19th century artifact scatter associated with homesteading. Local informants reported that the homestead was erected in the 1890s and torn down in 1946. Ceramic, glass, and metal artifacts were recorded, most with manufacturing dates between 1890 and 1910. No subsurface features were identified during shovel testing, and the site was severely disturbed at the time of recording. The investigators who recorded the site recommended that the site was not significant and that no further work on the site was needed.
Enclosure NOC-AE-1 1002691 Page 2 Site 41MG49 was originally reported in the License Renewal ER as having no site form.
However, upon revisiting the information provided by the Texas Archaeological Research Laboratory, the missing site record form was discovered. This site is located 3.97 miles northeast of the STP site and is a shell midden with no associated artifacts. The shell midden consists of oyster (95%) and freshwater clam (5 %) shells. Shovel tests were excavated at the site, but no artifacts were identified. The investigators who recorded the site recommended that the site was significant and that further work should be conducted if it would be impacted.
Site 41MG112 is 4.65 miles northeast of the STP site and is a dismantled historic farmstead dating to the mid-20th century. According to maps, this site once contained at least three structures. At the time of recording, the site consisted'of a scatter of historic artifacts associated with a farmstead (wire nails, asphalt shingles, window and bottle glass, metal cans, white ware ceramics, etc.) and remains of one structure (foundation posts, lumber debris, etc.). Shovel tests were excavated at the site, but no additional features were identified. The investigators who recorded the site recommended that the site was not significant and that no further work on the site was needed.
Formal concurrence by the Texas State Historic Preservation Officer on National Register of Historic Places eligibility for any of the three sites could not be found.
NRC Requested Information:
- 2. The ER states that a historic grave is located on the STP site. Describe the potential ground disturbing activities (if any) that may take place in this area of the STP site associated with license renewal, Units I and 2, or combined license, Units 3 and 4 (i.e., cumulative impact), activities. Describe the process that STP will follow, if ground disturbing activities occur in this area in the future, for mitigation of adverse impact to cultural resources.
STPNOC Response License renewal for STP Units 1 and 2 will not involve any ground-disturbing activities.
The site was originally planned for four reactors. STP Nuclear Operating Company (STPNOC) submitted comprehensive information on the site and surrounding area to NRC in its application for a combined operating license (COL) (Reference 1). NRC reviewed the COL application and prepared a Final Environmental Impact Statement (Reference 2), which analyzed the impacts on the surrounding communities and natural resources to determine if the STP site is suitable to support additional nuclear power generation. In the FEIS, NRC also evaluated the cumulative impacts of the four units on the surrounding environment.
NRC's cumulative impact analysis considered the possible life extension of Units 1 & 2 by 20 years (Section 2.15 of the License Renewal Application ER - Reference 3).
The COL ER (Reference 1) concluded that Unit 3 & 4 construction activities would not impact the grave site since all ground disturbing activities would occur several miles from the grave site and would be conducted in accordance with STP site environmental compliance procedures.
Enclosure NOC-AE-1 1002691 Page 3
References:
- 1. South Texas Project Units 3 and 4 COLA (Environmental Rpt), Rev 4. (ML102860592)
- 2. U.S.NRC, "Environmental Impact Statement for Combined Licenses (COLs) for South Texas Project Electric Generating Station Units 3 & 4, Final Report, NUREG-1 937, Vol.1, February 2011. (ML100770015)
- 3. STPNOC Letter from G. T. Powell to NRC Document Control Desk, "License Renewal Application", dated October 25, 2010 (NOC-AE-1 0002607) (ML103010257)